• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 112
  • 3
  • Tagged with
  • 117
  • 117
  • 91
  • 49
  • 43
  • 37
  • 33
  • 29
  • 26
  • 21
  • 20
  • 19
  • 18
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Confinamento dado por lajes e vigas melhorando a resistência do pilar que as cruza. / Confinement given for slabs and beams improving the strength of the column that crosses them.

Cristiana Furlan Caporrino 29 May 2007 (has links)
O objetivo deste trabalho foi estudar o efeito do confinamento em encontros de pilares de concreto com uma determinada resistência à compressão com lajes ou vigas de concreto de menor resistência. Com isso pretendeu-se desenvolver um melhor entendimento desse assunto, ainda pouco explorado, avaliar recomendações de algumas normas e, onde necessário e possível, sugerir uma solução alternativa. Foram ensaiados à compressão axial vinte e dois modelos reduzidos que representavam pilares de canto ou internos, incorporando parte da laje, e pilares isolados, cujos resultados foram comparados com recomendações de normas, ACI-318, CSA 23.3 e pesquisadores como, Gamble e Klinar, Ospina e Alexander, Bianchini e Silveira dos Santos. Na verdade, esta pesquisa é um prosseguimento daquela realizada por Silveira dos Santos. Complementando os estudos experimentais, modelos em elementos finitos possibilitaram a melhor compreensão desse efeito e ainda viabilizaram a comparação dos resultados experimentais com o critério de confinamento sugerido pelo CM CEB-FIP e pelo Eurocode EC2. Concluiu-se que apenas para pilares internos, cercados por laje em toda a volta, há um aumento de resistência do conjunto por efeito do confinamento do concreto da laje, devendo-se ainda respeitar certos limites. Para pilares de canto é necessária a utilização de algum elemento que compense a falta do concreto, como por exemplo, uma armadura transversal. / The goal of this paper is to study the effect of the confinement in connections of concrete columns having certain strength with lower strength concrete slabs or beams. It was intended to develop a better understanding of this subject, still little explored, to evaluate some code recommendations and, where necessary and possible, to suggest a alternative solution. Twenty-two specimens of reduced models were tested in compression representing corner or internal columns, incorporating part of the slabs, and isolated columns. These results were compared with recommendations of codes, ACI- 318, CSA 23,3 and researchers as, Gamble and Klinar, Ospina and Alexander, Bianchini and Silveira dos Santos. Indeed, this research is a continuation of that one carried through by Silveira dos Santos. Complementing the experimental studies, finite elements models made possible the best understanding of this effect and still they had made possible the comparison of the experimental results with the confinement criterion suggested for CM CEB-FIP and Eurocode EC2. It had concluded that only for internal columns, surrounded by slab, there is a strength increase of the specimen caused by confinement of the slab\'s concrete respecting certain limits. For corner columns it\'s necessary the utilization of some element that compensates the missing concrete, for example, a transversal reinforcement.
12

Análise teórica e experimental do comportamento ao cisalhamento de vigas em alvenaria estrutural de blocos de concreto / Numerical and experimental analysis of the shear behaviour of concrete block masonry beams

Moraes, Rafael Santos de 19 December 2017 (has links)
O comportamento mecânico de vigas em alvenaria estrutural submetidas ao cisalhamento é abordado de forma aprofundada neste trabalho. São apresentados neste estudo um extensivo levantamento bibliográfico, o qual estabelece um panorama sobre o tema, um programa experimental com ensaios de caracterização do material alvenaria e de vigas em escala natural e um estudo numérico das vigas ensaiadas em laboratório. Na etapa de caracterização dos materiais o comportamento compósito da alvenaria é analisado por meio de prismas submetidos à compressão em duas direções ortogonais, normal e paralela à junta. Para o estudo das vigas são realizados trinta e sete ensaios, nos quais são avaliadas as influências da geometria, das taxas de armaduras e da relação a/d (em que a é a distância da carga aplicada até o apoio e d é a altura útil) na capacidade resistente ao cisalhamento. Posteriormente, é realizada a modelagem numérica através do software DIANA® com o propósito de complementar as análises dos ensaios. A partir dos resultados experimentais e numéricos pôde-se concluir que, com exceção das vigas com armaduras longitudinais de 10 mm de diâmetro, os demais modelos atingiram a ruína por cisalhamento, devido à ausência de estribos ou pela sua insuficiência. O aumento da taxa de armadura longitudinal de 0,45 para 1,18% resultou em um incremento de 18,4% na resistência ao cisalhamento convencional. Para as duas geometrias (vigas com duas e três fiadas) e as duas relações a/d (0,77 e 1,72), constatou-se que não há uma melhora significativa na capacidade resistente quando a taxa de armadura transversal é aumentada de 0,05 para 0,07%. Os mecanismos resistentes, como o efeito de pino, foram efetivos na resistência dos modelos. Por fim, as análises numéricas reproduziram de forma satisfatória os experimentos, tanto no que diz respeito ao comportamento pré e pós-pico quanto na previsão da força última. / This work is an in depth study about the mechanical behaviour of masonry beams subjected to shear forces. An extensive literature review, which establishes a panorama on the subject, an experimental program considering material characterization and full scale beams tests and a numerical study for the tested beams are presented. For the beams, thirty seven tests are carried out in which the influence of geometry, reinforcements ratio and a/d ratio (where a is the distance from the load to adjacent support and d is the effective depth) on the shear strength are evaluated. Computational modelling is performed using the DIANA® software in order to complement the experimental results. From the experimental and numerical results it was possible to conclude that, except for beams with 10 mm diameter steel bar, the other models failed in shear, due to the absence of stirrups or their insufficiency. An increase in longitudinal reinforcement ratio from 0,45 to 1,18% improved the theoretical shear strength in 18,4%. For the beams with two and three courses and for a/d ratios 0,77 and 1,72 it was found that there is no significant improvement on the load capacity when the transverse reinforcement ratio is increased from 0,05 to 0,07%. Shear strength mechanisms, such as the dowel action, were effective in the models load capacity. Finally, the numerical analyzes satisfactorily reproduced the experiments, regarding to the pre and post-peak behaviour and in the prediction of the ultimate load.
13

Análise teórica e experimental de pilares de concreto armado sob ação de força centrada com resistência média à compressão do concreto de 40MPa / Theoretical and experimental analysis of reinforced concrete columns under concentric compression with concrete strength of 40MPa

Oliveira, Walter Luiz Andrade de 28 April 2004 (has links)
O objetivo primordial da pesquisa foi obter informações sobre o comportamento dúctil de pilares submetidos à compressão centrada moldados com concreto de resistência média à compressão de 40MPa. Os resultados obtidos experimentalmente foram confrontados com da análise numérica e se mostraram satisfatórios. O modelo adotado para análise teórica considerou as equações de equilíbrio que regem a segurança da seção transversal, e, o comportamento do pilar confinado. Para o desenvolvimento da parte experimental foram ensaiados 16 modelos de concreto armado: quatro com dimensões da seção transversal de 200mm x 200mm e altura de 1200mm e doze com dimensões da seção transversal de 150mm x 300mm e altura de 900mm, que apresentaram melhora no comportamento dúctil diretamente influenciada pelo aumento da taxa de armadura transversal. Foi verificado, também, o comportamento dúctil de pilares variando-se a resistência à compressão do concreto, a partir de dados experimentais de outros autores e deste trabalho. O comportamento de pilares se torna frágil com o aumento da resistência à compressão, assim foi gerada uma superfície que mostra o comportamento dúctil de pilares em função da taxa de armadura transversal e da resistência à compressão do concreto. Moldaram-se também, oito modelos não armados, para determinação do coeficiente K2, que leva em consideração a estimativa da resistência do concreto na estrutura, quando avaliada por meio de corpos-de-prova cilíndricos, e verificou-se que o valor desta variável diminui com o aumento da resistência à compressão do concreto, como sugere a norma Norueguesa. A utilização da variável K2 em função da resistência do concreto torna possível o dimensionamento de pilares de concreto de alta resistência considerando-se a seção íntegra ao invés da seção do núcleo / The main purpose of this research is to obtain information about the ductile behavior of concrete columns under concentric compression with concrete’s compressive strength of 40MPa. The experimental results were compared with those from a numerical analysis. The theoretical analysis was made using the equations that govern the safety of the cross section and the columns confinement behavior. For the development of the experimental program 16 specimens of reinforced concrete were tested: four with a 200mm x 200mm cross section and 1200mm height, and twelve with a 150mm x 300mm cross section and 900mm height, which presented improvement directly in the ductile behavior influenced by the increase in the rate of transverse reinforcement. It was also verified that the ductile behavior of columns with variations of the compressive strength of concrete, starting from third-party experimental data and from experimental results from this work, becomes fragile with the increase in concrete’s compressive strength. Thus, a surface was drawn showing the ductile behavior of concrete columns in function of the rate of traverse reinforcement and the concrete’s compressive strength. Eight specimens of plain concrete were also tested to determine the K2 coefficient that takes into account the estimate of the resistance for the concrete used in the column when appraised through cylindrical specimens. It was verified that the value for this variable decreases with the increase of the concrete’s compressive strength, as the Norwegian norm suggests. The use of the K2 coefficient in function of the concrete’s compressive strength turns possible calculate high-strength concrete columns being considered the complete section instead the nucleus section
14

Análise experimental da geração de alternativas em decisões estratégicas não estruturadas / Experimental analysis of option generation in strategic and ill-structured decision making

Dacorso, Antonio Luis Rocha 02 February 2005 (has links)
A decisão estratégica é tipicamente não estruturada, no sentido de que não existe processo semelhante na memória da organização. Essa estruturação corresponde ao cenário exposto de forma clara, com suas questões, hipóteses e objetivos. A qualidade da decisão estratégica depende principalmente do processo e da competência daqueles que participam dela. Gerar alternativas criativas e viáveis é uma etapa fundamental do processo de tomada de decisão, responsável em grande parte pela qualidade almejada. Entretanto, as pesquisas sobre geração de alternativas têm indicado consistentemente que as pessoas não são eficientes nessa atividade. Buscando-se as explicações para esse fato surgiram lacunas na literatura que serviram de inspiração para o presente estudo. Qual a influência das heurísticas e da isolação entre as etapas convergente e divergente na geração de alternativas? Para explorar essas lacunas e conhecer o desempenho do administrador brasileiro ao gerar alternativas foi realizado um experimento com 174 alunos de cursos MBA, de 4 escolas da Grande São Paulo. O resultado desse experimento propiciou algumas conclusões interessantes como a confirmação do baixo desempenho em geração de alternativas. O desafio para preencher as lacunas observadas permanece e as hipóteses da pesquisa, relacionando as heurísticas e a isolação como fatores que influenciam o desempenho, não foram aceitas. O estudo é uma confluência da pesquisa experimental, oriunda da psicologia cognitiva da decisão, com a visão da ciência da decisão organizacional. Essa linha de pesquisa se mostrou praticamente inexplorada nos estudos em administração desenvolvidos no Brasil. / The strategic decision-making is typically non-structured because there is no similarity process in the memory of the organizations. This structural model would involve a context of elements such as questions, hypotheses and objectives exposed in a quite clear way. The quality of the strategic decision-making depends mainly on its own process and on the competence of the individuals involved. An essential part of the making decision process is to generate creative and viable options that are also responsible for the quality of the process. However, researches on option-generating procedures have consistently suggested that people are not efficient in this kind of task. The present study was inspired by the fact that the current literature lacks studies explaining the reasons why this happen. What is the influence of the heuristics and isolation strategies on the convergent and divergent phases for generating options? In order to investigate this issue and understand the performance of the Brazilian managers for generating options, an experiment was conduct in 174 individuals studying in MBA courses at 4 educational institutions in the urban city area of São Paulo. The results led to some interesting conclusions such as the confirmation of the poor performance for generating options. The challenge and the lack remain mainly because the hypotheses tested, i.e., the heuristic and isolation strategies for generating options, were not effective. The present study is a confluence of two different decision approaches: the experimental research (based on cognitive psychology) and the management science. This line of research hasn’t been explored in the management field in Brazil.
15

Análise teórica e experimental de pilares de concreto armado sob ação de força centrada com resistência média à compressão do concreto de 40MPa / Theoretical and experimental analysis of reinforced concrete columns under concentric compression with concrete strength of 40MPa

Walter Luiz Andrade de Oliveira 28 April 2004 (has links)
O objetivo primordial da pesquisa foi obter informações sobre o comportamento dúctil de pilares submetidos à compressão centrada moldados com concreto de resistência média à compressão de 40MPa. Os resultados obtidos experimentalmente foram confrontados com da análise numérica e se mostraram satisfatórios. O modelo adotado para análise teórica considerou as equações de equilíbrio que regem a segurança da seção transversal, e, o comportamento do pilar confinado. Para o desenvolvimento da parte experimental foram ensaiados 16 modelos de concreto armado: quatro com dimensões da seção transversal de 200mm x 200mm e altura de 1200mm e doze com dimensões da seção transversal de 150mm x 300mm e altura de 900mm, que apresentaram melhora no comportamento dúctil diretamente influenciada pelo aumento da taxa de armadura transversal. Foi verificado, também, o comportamento dúctil de pilares variando-se a resistência à compressão do concreto, a partir de dados experimentais de outros autores e deste trabalho. O comportamento de pilares se torna frágil com o aumento da resistência à compressão, assim foi gerada uma superfície que mostra o comportamento dúctil de pilares em função da taxa de armadura transversal e da resistência à compressão do concreto. Moldaram-se também, oito modelos não armados, para determinação do coeficiente K2, que leva em consideração a estimativa da resistência do concreto na estrutura, quando avaliada por meio de corpos-de-prova cilíndricos, e verificou-se que o valor desta variável diminui com o aumento da resistência à compressão do concreto, como sugere a norma Norueguesa. A utilização da variável K2 em função da resistência do concreto torna possível o dimensionamento de pilares de concreto de alta resistência considerando-se a seção íntegra ao invés da seção do núcleo / The main purpose of this research is to obtain information about the ductile behavior of concrete columns under concentric compression with concrete’s compressive strength of 40MPa. The experimental results were compared with those from a numerical analysis. The theoretical analysis was made using the equations that govern the safety of the cross section and the columns confinement behavior. For the development of the experimental program 16 specimens of reinforced concrete were tested: four with a 200mm x 200mm cross section and 1200mm height, and twelve with a 150mm x 300mm cross section and 900mm height, which presented improvement directly in the ductile behavior influenced by the increase in the rate of transverse reinforcement. It was also verified that the ductile behavior of columns with variations of the compressive strength of concrete, starting from third-party experimental data and from experimental results from this work, becomes fragile with the increase in concrete’s compressive strength. Thus, a surface was drawn showing the ductile behavior of concrete columns in function of the rate of traverse reinforcement and the concrete’s compressive strength. Eight specimens of plain concrete were also tested to determine the K2 coefficient that takes into account the estimate of the resistance for the concrete used in the column when appraised through cylindrical specimens. It was verified that the value for this variable decreases with the increase of the concrete’s compressive strength, as the Norwegian norm suggests. The use of the K2 coefficient in function of the concrete’s compressive strength turns possible calculate high-strength concrete columns being considered the complete section instead the nucleus section
16

A numerical and experimental analysis of fatigue and fracture mechanics problems

Azevedo, Paulo Coelho Moreira January 2008 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2008
17

Comportamento do betão reforçado com fibras : análise experimental e simulação numérica

Barros, Joaquim António Oliveira de January 1995 (has links)
Dissertação apresentada para obtenção do grau de Doutor em Engenharia Civil, na Faculdade de Engenharia da Universidade do Porto, sob a orientação do Prof. Doutor Joaquim Azevedo Figueiras
18

Transições aterro-estrutura em linhas ferroviárias de alta velocidade : análise experimental e numérica

Ribeiro, Ana Cristina Carvalhinho Alves January 2012 (has links)
Tese de doutoramento. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2012
19

Construção e validação de um túnel de vento para ensaios de estimativa da deriva em pulverizações agrícolas

Moreira Júnior, Orlando [UNESP] 09 October 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-10-09Bitstream added on 2014-06-13T20:22:35Z : No. of bitstreams: 1 moreirajunior_o_dr_botfca.pdf: 1169550 bytes, checksum: c39cff16dc4995bbd4495b150b625901 (MD5) / Este trabalho teve por objetivo a construção de um túnel de vento em escala reduzida e de baixo custo para utilização em estudos de tecnologia de aplicação de agrotóxicos, com posterior validação através da avaliação dos efeitos de diferentes adjuvantes pulverizados por uma ponta na intensidade do processo de deriva. Os ensaios foram conduzidos no Laboratório de Máquinas para Pulverização do Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA) da FCA/UNESP - Departamento de Engenharia Rural, localizado no campus da UNESP da cidade de Botucatu. O túnel de vento construído teve como principais características ser de circuito aberto e seção de teste fechada, com o sistema acionador (motor) abastecendo o circuito e agindo como soprador. Logo após o motor foram colocadas duas telas e uma colméia, com a finalidade de uniformizar o fluxo de ar que se desloca para a seção de testes onde são feitas as medidas. O túnel de vento foi confeccionado com chapas de fibras de eucalipto de espessura 3,0 mm e face superior lisa e face inferior corrugada, tendo comprimento total de 4,80 m, uma secção de testes quadrada de 56 cm x 56 cm e área útil de aproximadamente 0,31 m2 e 2,5 m de comprimento. Para o acionamento do túnel utilizou-se um ventilador de 5 velocidades e 180 W de potência. Todo sistema foi dimensionado para fornecer fluxo laminar de ar a uma velocidade de 2,0 m.s-1. Os ensaios de validação foram realizados com uma ponta de pulverização XR8003 (jato plano convencional de uso amplo) a uma pressão de 2 bar, produzindo um espectro de gotas médias, utilizada para aplicação de caldas (soluções em água) contendo o corante Azul Brilhante a 0,6% v/v em 9 mistura ou não com dois adjuvantes. Os primeiro adjuvante é um redutor de deriva a base de polímeros, utilizado na concentração... / The aim of this study was to build a low cost reduced-scale wind tunnel for drift evaluation on pesticide application technology. Validation studies were undertaken by evaluating the effect of different adjuvants on the drift caused by the spray of a single nozzle. The work was carried out at the NEMPA - Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA), FCA/UNESP, Departamento de Engenharia Rural, Botucatu/SP, Brazil. The wind tunnel main characteristics were an open circuit and a closed working section with a fan blowing air into the tunnel. Screens were fitted downstream after the fan in order to stabilize the air flow on the working section. The tunnel was built with 3.0 mm eucalyptus hardboard, with a total length of 4.8 m and a squared section of 0.56 m. The working section had 0.31 m2, with a total length of 2,5 m. The air flow was provided by a 180 W axial fan. The system was adjusted and calibrated to provide a laminar and stable flow at 2.0 m s-1. Validation studies were carried out by using a XR 8003 flat fan nozzle at 2 bar (medium droplets) that was used to spray solutions containing water plus a food dye (Blue FDC) at 0,6% v/v mixed with the folowing adjuvants: a polymer based anti drift formulation at 0,06% m/v and a nonylphenol based surfactant at 0,2% v/v. After a 10-second application drift was collected on nylon strips transversally fixed along the tunnel at different distances from the 11 nozzle and different high from the bottom part of the tunnel. Drift deposits were avaluated by spectrophotometry at the NUPAM (Núcleo de Pesquisas Avançadas em Matologia), Departamento de Produção Vegetal/UNESP/FCA, Botucatu,SP, Brazil. The results showed that the tunnel was effective to enable comparative drift measurements on the spray solution used in this work making possible the evaluation of drift risk under... (Complete abstract click electronic access below)
20

Construção de um dispositivo de simulação do escoamento pulsátil em artérias

Machado, Danilo Agostini [UNESP] 26 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-26Bitstream added on 2014-06-13T20:55:54Z : No. of bitstreams: 1 machado_da_me_ilha.pdf: 1511743 bytes, checksum: 02f8492fa42747b8dd47642f8ed0d7f9 (MD5) / Este projeto visa à análise cinemática de um arranjo experimental capaz de reproduzir o fluxo sanguíneo em artérias. O mecanismo procura realizar esse escoamento através de um sistema came-seguidor juntamente com um sistema hidráulico, utilizando êmbolo e duas válvulas controladoras de fluxo. O mecanismo came-seguidor será utilizado devido a sua versatilidade em garantir que o escoamento sanguíneo ocorra durante um ciclo cardíaco. A came será radial com seguidores de roletes. O seguidor de roletes será ligado ao cilindro hidráulico que controla o fluxo sanguíneo. Um tubo de látex foi acoplado ao sistema hidráulico representando a aorta abdominal, foi confeccionado com as dimensões reais desta artéria e o látex foi escolhido, pois possui um coeficiente de elasticidade muito próximo da artéria. Um manômetro foi acoplado ao sistema para medir a pressão no interior do tubo de látex. Na sequência um tubo de complacência simular as perdas de carga do sistema circulatório. O deslocamento radial do tubo de látex e variação de pressão do manômetro foram monitorados através de filmagem. Posteriormente, os resultados experimentais foram comparados e validados com os resultados numéricos obtidos com o programa ANSYS e com a literatura / This project aims to kinematic analysis of an experimental apparatus able to reproduce the blood flow in arteries. The mechanism cam-follower and the hydraulic system using piston and two controlling valves of flow were used to realize the fluid flow. The camfollower mechanism was used to ensure that the fluid flow occurs during the cardiac cycle. The cam is radial with roller followers. The follower roller is connected to the hydraulic cylinder which controls the fluid flow. A latex tube was attached to the hydraulic system representing the abdominal aorta. The latex tube has the same real dimensions of this artery and it was chosen due the modulus of elasticity very close to the artery. A manometer was used to measure the outlet pressure of latex tube. After latex tube there is a complacency tube to control the pressure drop of circulatory system. The radial displacement of the latex tube and pressure variation of the manometer were monitored through filming. The experimental results were compared and validated with numerical results obtained with ANSYS software and with literature

Page generated in 0.1011 seconds