• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas / Use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry

Santos, Allan Cezar Vieira dos 09 June 2006 (has links)
Esta dissertação descreve o uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas. O estudo indicou que na faixa de pH entre 4 e 6 não há diferença entre a utilização de vermiculita expandida ou não-expandida na remoção dos íons. Observou-se que nos pH\'s avaliados o tempo de interação de 180 minutos foi suficiente para que o sistema atingisse o equilíbrio. Pode-se afirmar que a vermiculita não expandida apresenta as seguintes ordens de afinidade pelo cátions considerados: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). Nas condições de trabalho, os ensaios envolvendo a coluna de vermiculita não evidenciaram uma melhor capacidade de extração dos íons estudados frente ao sistema de extração em batelada. Percentuais de extração da ordem de 76% em amostra de efluente no sistema em batelada reforçam a viabilidade do uso da vermiculita como adsorvente destes metais. Um método SIA-ASV (análise por injeção seqüencial - voltametria de redissolução anódica) foi proposto e validado. Para um tempo de deposição de 80 s e vazão de 10 µLs-1, os limites de detecção foram 0,06, 0,09 e 0,16 µmolL-1 para Cd, Pb e Cu, respectivamente, além de apresentar uma faixa linear de trabalho entre 0,2 e 9,0 µmolL-1. / This dissertation describes the use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry. The study indicated that under pH range from 4 to 6 there is no difference on using expanded or not expanded vermiculite for removal of ions. It was also observed that at any evaluated pH, a 180 minutes interaction time was long enough to allow the system reach equilibrium. It\'s possible to state that non-expanded vermiculite presents the following affinity orders by the studied ions: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). At working conditions, tests involving vermiculite columns didn\'t show a better performance on extracting these ions when faced to batch extraction systems. Extraction percentuals of about 76% were obtained using a sample of coatings industry wastewater, reinforcing the viability of the use of vermiculite as an adsorbent of these metals. A SIA-ASV (sequential injection analysis - anodic stripping voltammetry) method was proposed and validated. For a deposition time of 80 s and a flow rate of 10 µL s-1, detection limits were 0.06, 0.09 and 0.16 µmol L-1 to Cd, Pb and Cu, respectively; a linear working range, between 0.2 and 9.0 µmol L-1 was also determined.
2

Exploração da degradação de sulfito assistida por ultra-som para a determinação indireta de açúcares redutores empregando análise por injeção seqüencial.

Santiago Neto, Antonio Inacio January 2006 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2013-04-23T11:00:55Z No. of bitstreams: 1 Santiago Neto.pdf: 777271 bytes, checksum: 7b5d519ad6bf5809028c74aefc018b57 (MD5) / Made available in DSpace on 2013-04-23T11:00:55Z (GMT). No. of bitstreams: 1 Santiago Neto.pdf: 777271 bytes, checksum: 7b5d519ad6bf5809028c74aefc018b57 (MD5) Previous issue date: 2006 / Métodos para a determinação de açúcares redutores totais em alimentos explorando a técnica de análise em fluxo têm sido reportados na literatura. Na estrutura dos açúcares redutores há um grupo carbonila capaz de formar adutos com S(IV) em pH entre 4 e 5. No presente trabalho, a concentração de açúcares redutores totais foi determinada monitorando a concentração dos íons sulfito ligados a grupos carbonílicos empregando a técnica de análise por injeção seqüencial. A p-rosanilina foi empregada para a monitoração espectrofotométrica do sulfito ligado a 580 nm. Foi observado que o excesso de sulfito foi oxidado prontamente a sulfato por radicais hidroxila produzidos durante irradiação ultrasônica como também o tratamento de ultra-som foi incapaz de decompor os adutos. Os adutos foram decompostos pela alcalinização da zona da amostra. O sistema SIA foi desenvolvido para determinação de açúcares redutores totais na faixa de concentração de 6,0x10-6 a 1,0x10-4 mol L-1. O limite de detecção de açúcares redutores totais foi de 6,5x10-7 mol L-1 e o desvio padrão relativo para 10 determinações consecutivas foi menor que 2%. A concentração de açúcares redutores totais em soro glicosado foi determinada pelo método proposto e os resultados foram comparados ao método de referência, não apresentando diferença significativa para um nível de confiança de 95%. / Salvador
3

Uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas / Use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry

Allan Cezar Vieira dos Santos 09 June 2006 (has links)
Esta dissertação descreve o uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas. O estudo indicou que na faixa de pH entre 4 e 6 não há diferença entre a utilização de vermiculita expandida ou não-expandida na remoção dos íons. Observou-se que nos pH\'s avaliados o tempo de interação de 180 minutos foi suficiente para que o sistema atingisse o equilíbrio. Pode-se afirmar que a vermiculita não expandida apresenta as seguintes ordens de afinidade pelo cátions considerados: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). Nas condições de trabalho, os ensaios envolvendo a coluna de vermiculita não evidenciaram uma melhor capacidade de extração dos íons estudados frente ao sistema de extração em batelada. Percentuais de extração da ordem de 76% em amostra de efluente no sistema em batelada reforçam a viabilidade do uso da vermiculita como adsorvente destes metais. Um método SIA-ASV (análise por injeção seqüencial - voltametria de redissolução anódica) foi proposto e validado. Para um tempo de deposição de 80 s e vazão de 10 µLs-1, os limites de detecção foram 0,06, 0,09 e 0,16 µmolL-1 para Cd, Pb e Cu, respectivamente, além de apresentar uma faixa linear de trabalho entre 0,2 e 9,0 µmolL-1. / This dissertation describes the use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry. The study indicated that under pH range from 4 to 6 there is no difference on using expanded or not expanded vermiculite for removal of ions. It was also observed that at any evaluated pH, a 180 minutes interaction time was long enough to allow the system reach equilibrium. It\'s possible to state that non-expanded vermiculite presents the following affinity orders by the studied ions: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). At working conditions, tests involving vermiculite columns didn\'t show a better performance on extracting these ions when faced to batch extraction systems. Extraction percentuals of about 76% were obtained using a sample of coatings industry wastewater, reinforcing the viability of the use of vermiculite as an adsorbent of these metals. A SIA-ASV (sequential injection analysis - anodic stripping voltammetry) method was proposed and validated. For a deposition time of 80 s and a flow rate of 10 µL s-1, detection limits were 0.06, 0.09 and 0.16 µmol L-1 to Cd, Pb and Cu, respectively; a linear working range, between 0.2 and 9.0 µmol L-1 was also determined.
4

Desenvolvimento de processo para incorporação da etapa de otimização de parâmetros analíticos em procedimentos automatizados de análises por injeção sequencial

Soares, Vitória Regina Bispo January 2009 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-08-31T12:55:32Z No. of bitstreams: 1 Dissertação de Vitória Regina B. Soares.pdf: 4140552 bytes, checksum: cfbde6e68fae6f80c2843951ea61ffde (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-02T15:48:05Z (GMT) No. of bitstreams: 1 Dissertação de Vitória Regina B. Soares.pdf: 4140552 bytes, checksum: cfbde6e68fae6f80c2843951ea61ffde (MD5) / Made available in DSpace on 2016-09-02T15:48:05Z (GMT). No. of bitstreams: 1 Dissertação de Vitória Regina B. Soares.pdf: 4140552 bytes, checksum: cfbde6e68fae6f80c2843951ea61ffde (MD5) / CNPq / Para aumentar o nível de automatização no desenvolvimento de procedimentos analíticos em sistemas de análises por injeção sequencial foi proposta uma rotina em linguagem QuickBasic que permitia incorporar a etapa de otimização multivariada como uma das etapas do processo analítico, simplificando o gerenciamento do sistema. A rotina foi desenvolvida para sistemas de análises por injeção sequencial, uma vez que esta estratégia de análises em fluxo pode executar diferentes procedimentos sem reconfiguração do sistema. O processo automatizado de otimização, calibração e medida foi aplicado para as determinações espectrofotométricas de ferro total e de captopril em medicamentos, empregando os métodos da 1,10-o-fenantrolina e do acoplamento com o radical iminoquinona, respectivamente. Para rotina de otimização desenvolvida foi selecionado o sinal líquido como resposta e a intervenção do operador se restringiu a selecionar as variáveis do sistema sob otimização, definir os domínios experimentais de cada variável e escolher o desenho experimental a ser executado. Entretanto, caso as condições ótimas não fossem encontradas no domínio experimental selecionado a rotina foi programada de modo a sugerir ao operador os deslocamentos que deveriam ser feitos nos domínios experimentais. Os fatores investigados para a determinação de ferro total em amostras de fortificantes foram os volumes amostrados dos reagentes e a vazão da solução transportadora, enquanto que para o captopril foram investigados os volumes amostrados dos reagentes, a acidez da solução do oxidante e da solução da amina aromática, além da vazão da solução transportadora. Nas condições otimizadas os graus de sopreposição de zonas para ambos os procedimentos variaram entre 0,79 e 1, indicando a eficiente mistura das soluções das amostras e reagentes no percurso analítico. O procedimento SIA otimizado para a determinação do teor de ferro total em fortificantes apresentou baixa dispersão (<2%), limite de quantificação de 1,43 mg L-1 , com consumo de 0,7 mg de 1,10-o- fenantrolina e 6 mg de ácido ascórbico por determinação. A freqüência analítica foi de 60 determinações h-1 e os resultados obtidos para diferentes amostras de fortificantes foram comparados com o mesmo método em batelada e não apresentaram diferenças significativas para 95% de confiabilidade. Trinta determinações de captopril em produtos farmacêuticos por hora de trabalho foram executadas pelo procedimento de análise por injeção seqüencial otimizado consumindo 0,15 mg de sulfato de N-N-dimetil-p-fenilodiamina (DMPD) e 4 mg de FeCl3.6H2O por determinação. Faixa linear de trabalho entre 2,65 e 100 mg L-1 e boa precisão (ca. 1%) foram também obtidas. Os teores de captopril em amostras de produtos farmacêuticos foram determinados pelo procedimento proposto e os resultados, quando comparados com o método iodométrico de referência, não apresentaram diferenças significativa para 95% de confiança / A QuickBasic routine was proposed to increase the automatization in the development of analytical process for sequential injection analysis system in order to permit the inclusion of multivariated optimization as one of the steps of analytical process leading to simplify the system management. The routine was developed for sequential injection analysis once this flow analysis strategy can perform diverse analytical procedures in the same manifold. The automatized process for optimization, calibration and measurement was applied to determine the total iron concentration in pharmaceutical formulations by 1,10-o-phenantroline spectrophotometric method, as well as captopril in pharmaceutical formulations based on coupling reaction with iminoquinone radical. Sensitivity (net signal) was selected as dependent parameter for the optimization step and the analyst action was limited to select the parameters to be optimized and the experimental design to be used as well to define the experimental domains of all parameters. A decision of the analyst was also expected in the cases where the optimal conditions were not attained in the domains previously selected and, once new domains are suggested by the software, a new sequence of experiments will be carried out with human agreement. Aliquots volumes of reagents and carrier solution flow rate were the parameters evaluated for total iron determination in supplements, while the acidity and volumes of reagents solutions and the flow rate of carrier solution were optimized for captopril determination flow procedure. For both analytical procedures in the optimized conditions the index of zone overlapping was varied from 0.79 and 1, suggesting an efficient mixture of solutions in the analytical path. The optimized SIA procedure for total iron determination in supplement samples has low dispersion (<2%), limit of quantification of 1.43 mg L-1, leading to consume 0.7 mg of 1,10-o-phenantroline and 6 mg of ascorbic acid per determination. An analytical throughput of 60 determinations h-1 was estimated and no significant difference (95% confidence level) was observed by comparing the results obtained by the flow method in optimized conditions and those obtained by the spectrophotometric procedure in batch mode. Thirty captopril determinations in pharmaceutical formulations per hour were carried out by employing the optimized sequential injection analysis procedure, consuming 0.15 mg of N,N-dimethyl-p-phenylenediamine (DMPD) and 4 mg of FeCl3.6H2O. Linear range from 2.65 to 100 mg L-1 with high precision (ca. 1%) was also obtained and no significant differences (95% confidence level) were observed by comparing the optimized flow procedure with the iodometric reference method.

Page generated in 0.0844 seconds