• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação de matriz de Doehlert na otimização de um sistema de pré-concentração em linha para determinação de cobre usando Espectrometria de absorção atômica com chama.

Bezerra, Marcos de Almeida January 2003 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2013-04-23T12:56:12Z No. of bitstreams: 1 Marcos Bezerra.pdf: 1922551 bytes, checksum: e3b8140a1a9d0fed601ddbd96fae6b7f (MD5) / Made available in DSpace on 2013-04-23T12:56:12Z (GMT). No. of bitstreams: 1 Marcos Bezerra.pdf: 1922551 bytes, checksum: e3b8140a1a9d0fed601ddbd96fae6b7f (MD5) Previous issue date: 2003 / Neste trabalho foi desenvolvido um sistema de pré-concentração em linha para determinação de cobre usando Espectrometria de Absorção Atômica em Chama (FAAS). O processo baseia-se na extração em fase sólida de íons cobre (II) em uma minicoluna de Amberlite XAD-2 impregnada com 2-(2-tiazoliazo)-5-dimetilaminofenol (TAM). A otimização das variáveis experimental deste sistema foi executada usando-se planejamento fatorial de dois níveis e matrix de Doehlert. As variáveis: vazão de amostragem (VA), vazão de eluição (VE), pH e concentração do tampão fosfato (CT) foram escolhidas como fatores na otimização. Os resultados do planejamento fatorial de dois níveis 24 com 16 corridas (em duplicata) foram avaliados através de Análise de Variância (ANOVA) demostrando que os fatores VA, VE e pH, são estatisticamente significativos, juntamente com as interações VE-pH, VA-VE, CT-pH, VA-CT e VE-CT. Em seguida, dois planejamentos Doehlert de duas variáveis foram aplicados para se encontrar as condições ótimas para pré-concentração e determinação do cobre. A robustez do sistema foi avaliada através de planejamentos fatoriais fracionários 27-4e 23-1, centrados nas condições experimentais estabelecidas na otimização do processo. Os resultados demonstraram que o sistema em linha é robusto para variações de ±10% da vazão de fluxo do eluente, da concentração do eluente e da concentração do tampão e 5% para o valor nominal do pH e da vazão de amostragem. O método proposto permitiu a determinação do cobre com limite de detecção (3s/S) de 0,23 mg L-1, e precisão calculada como desvio padrão relativo (RSD) de 3,9 e 3,7 % para concentrações de cobre de 5,00 e 20,00 mg L-1 respectivamente. O fator de pré-concentração para o sistema é de 62. A recuperação do cobre em uma amostra multielementar demonstrou que o processo tem seletividade suficiente para análise de amostras de alimentos. A exatidão foi verificada pela análise dos seguintes materiais de referência certificados: Farinha de arroz NIES 10a, Folhas de espinafre NIST 1570a, Folhas de maça NIST 1515 Folhas de pomar NBS 1571. O sistema otimizado foi aplicado para determinação de cobre em vários tipos de alimentos como: folhas de mandioca, folhas de agrião, folhas de alface, farinha de mandioca, farinha de trigo, farinha de soja e farinha de aveia. / Salvador
2

Desenvolvimento de procedimentos em fluxo envolvendo espectrofotometria convencional e com longo caminho óptico para determinação de ânions em águas / Development of flow procedures involving conventional spectrophotometry and long pathlenght for determination of anions in waters

Bonifacio, Viviane Gomes 22 February 2008 (has links)
Made available in DSpace on 2016-06-02T20:34:07Z (GMT). No. of bitstreams: 1 1949.pdf: 1264259 bytes, checksum: 668e8da6a5c7afa14551b12ccd924b26 (MD5) Previous issue date: 2008-02-22 / Universidade Federal de Minas Gerais / In this work, five procedures were developed for determination of anions (chloride, sulphate, phosphate and fluoride), with spectrophotometric detection, being four employing a 100-cm optical length flow-cell and one of them employing a cell whith 1 cm optical length. The first procedure employing flow injection analysis with long pathlenght for chloride determination in natural waters was based in the spectrophotometric procedure described in Standard Methods130 in which the reaction between mercury(II) thiocianate and chloride displace the thiocianate ions yielding a reddish complex with iron(III), that was spectrophotometrically monitored at 455 nm. The analytical curve obtained was linear in the chloride concentration range of 1.0 to 50 mg L-1 (r = 0.9989) with a detection limit of 0.2 mg L-1 (3óblank / slope) and a quantification limit of 0.7 mg L-1 (10óblank / slope), RSD < 1.0% (n = 20) and a sampling rate of 72 h-1. The second procedure for chloride determination employed a solid-phase reactor containing silver chloranilate immobilized coupled to the FIA system. The chloride determination is based on the reaction between chloride and silver chloranilate yielding silver chloride, displacing chloranilate ions which were spectrophotometrically detected at 530 nm and the absorbance signals proportional to the chloride concentration. The analytical curve showed a good linearity in the chloride concentration range of 0.5 to 100 mg L-1 (r = 0.9997) with a detection limit of 0.3 mg L-1 (3óblank / slope) and a quantification limit of 0.5 mg L-1 (10óblank / slope), RSD of 1.05% (n = 20) and a sampling rate of 80 h-1. The flow procedure for sulphate determination in natural waters employed a solid-phase reactor containing barium chloranilate immobilized. The determination is based on the reaction between sulphate ions and barium chloranilate yielding barium sulphate, displacing the chloranilate ions that were spectrophotometrically detected at 530 nm. The analytical curve obtained was linear in the sulphate concentration range of 2.5 to 40 mg L-1 ( r = 0.9994) a detection limit of 0.1 mg L-1 (3óblank / slope) and a quantification limit of 0.3 mg L-1 (10óblank / slope), RSD < 1.0% (n = 10) and a sampling rate of 50 h-1. The proposed procedure for phosphate determination in natural waters employing flow injection analysis with long pathlenght spectrophotometry is based on the colorless reaction of iron(III) thiocianate and phosphate ions. Iron(III) reacts with thiocianate yielding FeSCN2+, a reddish complex with maximum absorbance in 468 nm. The phosphate ions in contact with FeSCN2+ yield a colorless complex between iron(III) and phosphate, with non-defined stoichiometry. The decrease of the absorbance signals is proportional to the phosphate concentration in the samples. The analytical curve obtained was linear in the phosphate concentration range of 10 to 100 µg L-1 (r = 0.9996) a detection limit of 4.5 µg L-1 (3óblank / slope) and a quantification limit of 15.6 µg L-1 (10óblank / slope), RSD < 1.0% (n = 10) and a sampling rate of 55 h-1. The procedure for fluoride determination in mineral waters employing a 1-cm optical flow-cell was based on the same procedure for phosphate determination. The reaction between fluoride ions and FeSCN2+ yield the colorless FeF6 3-complex causing an absorbance decrease, proportional to the fluoride concentration in the samples. The analytical curve showed a good linearity for the fluoride concentration range of 0.02 to 5.33 mg L-1 (r = 0.9997) with a detection limit of 5.3 µg L-1 (3óblank / slope) and a quantification limit of 17.6 µg L-1 (10óblank / slope), RSD of 1.9% (n = 20) and a sampling rate of 110 h-1. Results obtained with the proposed procedures were compared with those obtained with the official methods from Standard Methods showing a good agreement at the 95% confidence level. / Neste trabalho, cinco procedimentos foram desenvolvidos para a determinação de ânions (cloreto, sulfato, fosfato e fluoreto), com detecção espectrofotométrica, sendo quatro empregando célula de 100 cm de caminho óptico e um empregando célula de 1 cm de caminho óptico. O primeiro procedimento utilizando análise por injeção em fluxo com longo caminho óptico para a determinação de cloreto em águas naturais baseou-se no método espectrofotométrico descrito no Standard Methods130 onde a reação entre tiocianato de mercúrio(II) e cloreto leva ao deslocamento dos íons tiocianato e à formação de um complexo de coloração vermelho intenso com Fe(III), que foi monitorado em 455 nm. A curva analítica obtida foi linear para o intervalo de concentrações de 1,0 a 50 mg L-1 de cloreto (r = 0,9989), com um limite de detecção de 0,2 mg L-1 (3óbranco / inclinação), um limite de quantificação de 0,7 mg L-1 (10óbranco / inclinação), RSD menor que 1,0 % (n = 20) e uma freqüência de amostragem de 72 h-1. O segundo procedimento utilizando análise por injeção em fluxo com longo caminho óptico para a determinação de cloreto em águas naturais empregou um reator em fase sólida contendo cloranilato de prata imobilizado. A determinação é baseada na reação entre o cloreto e o cloranilato de prata, formando cloreto de prata que fica retido no reator, deslocando os íons cloranilato que foram detectados espectrofotometricamente em 530 nm, sendo os sinais de absorbância proporcionais à concentração de cloreto. A curva analítica obtida apresentou linearidade no intervalo de concentrações de 0,5 a 100 mg L-1 de cloreto (r = 0,9997), um limite de detecção de 0,3 mg L-1 (3óbranco / inclinação), um limite de quantificação de 0,5 mg L-1 (10óbranco / inclinação), RSD de 1,05 % (n = 20) e uma freqüência de amostragem de 80 h-1. O procedimento para a determinação de sulfato em águas naturais empregou um reator em fase sólida contendo cloranilato de bário imobilizado. O princípio da determinação é baseado na reação entre o sulfato e o cloranilato de bário, formando sulfato de bário que fica retido no reator, deslocando os íons cloranilato que foram detectados espectrofotometricamente em 530 nm. A curva analítica obtida foi linear paro o intervalo de concentração de sulfato de 2,5 a 40 mg L-1 (r= 9994), com limite de detecção de 0,1 mg L-1 (3óbranco / inclinação), limite de quantificação de 0,3 mg L-1 (10óbranco / inclinação), RSD menor que 1,0 % (n = 10) e uma freqüência de amostragem de 50 h-1. O procedimento proposto para a determinação de fosfato em águas naturais utilizando análise por injeção em fluxo com longo caminho óptico, baseia-se na reação de descoloração do tiocianato de ferro (III) pelo fosfato. O nitrato de ferro (III) reage com o tiocianato de sódio formando o tiocianato de ferro (III), um composto de coloração avermelhada que possui absorção máxima em 468 nm. Quando os íons fosfato entram em contato com o complexo FeSCN2+, forma-se o complexo entre o fosfato e o ferro(III), de estequiometria não definida, que é incolor O decréscimo da absorbância, é proporcional à concentração de fosfato na amostra. A curva analítica foi linear par o intervalo de concentrações de 10 a 100 µg L-1 de fosfato (r = 0,9996), com limite de detecção de 4,5 µg L-1 (3óbranco / inclinação), limite de quantificação de 15,6 µg L-1 (10óbranco / inclinação), RSD de 0,5 % (n = 10) e freqüência de amostragem de 55 h-1. O procedimento para determinação de fluoreto em amostras de água mineral, empregando uma célula de 1 cm de caminho óptico, baseia-se no método empregado para a determinação de fosfato, sendo que quando os íons fluoreto entram em contato com o complexo FeSCN2+, forma-se o complexo FeF6 3-entre o fluoreto e o ferro, que é incolor, ocasionando um decréscimo da absorbância que é proporcional à concentração de fluoreto na amostra. A curva analítica apresentou boa linearidade para o intervalo de concentração de 0,02 a 5,33 mg L-1 de fluoreto (r = 9997), limite de detecção de 5,3 µg L-1 (3óbranco / inclinação), limite de quantificação de 17,6 µg L-1 (10óbranco / inclinação), RSD de 1,9 % (n = 20) com freqüência de amostragem de 110 h-1. Os valores obtidos com os procedimentos propostos foram comparados com aqueles obtidos pelo método oficial do Standard Methods, e os resultados estão em concordância a um nível de confiança de 95%.

Page generated in 0.1031 seconds