Estanho em amostras ambientais por espectrometria de fluorescência atômica (AFS)

Garcez, Daniel Locoselli [UNESP] 22 May 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:54:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-05-22. Added 1 bitstream(s) on 2016-04-01T18:00:26Z : No. of bitstreams: 1 000858508.pdf: 1868501 bytes, checksum: 6bd3202a23901808b34b5854cb3703f3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente estudo objetivou estabelecer um método analítico para determinação das concentrações de Sn em amostras naturais. Optou-se pelo acoplamento das técnicas analíticas de espectrometria de fluorescência atômica (AFS), geração de hidretos (HG) e sistema de injeção em fluxo (FI). O desenvolvimento do método considerou a otimização das condições de operação do AFS, da técnica de HG, do sistema FI e dos procedimentos de digestão de amostras ambientais (sólidas e líquidas). Os resultados obtidos demonstraram que as melhores condições para geração de SnH4 foram alcançadas com redutor (NaBH4) 4% (m/v) e ácido (HCl) 0,6 mol L-1. A vazão de injeção de amostra otimizadas foi de 1,2 mL min-1, e as vazões de fluxo de reagentes foram 1,2 mL min-1 de HCl e 1,6 mL min-1 para NaBH4. Nestas condições, foi obtida uma relação molar [BH4 −] / [H+] de 1,62 para as reações de geração de hidreto de Sn. O volume de amostra injetado foi definido como 500 μL. Para as digestões de solo e sedimento em equipamento de micro-ondas, foi definido o uso dos volumes de ácidos 3 mL HNO3 + 1 mL HCl. Após o desenvolvimento do método analítico, este foi aplicado em matrizes ambientais. Para tanto, foram realizadas amostragens de solo, sedimento e água, em duas áreas sob ação antrópica distintas, sendo estas: área de beneficiamento de cassiterita em Corumbataí/SP e área da Baía da Ilha Grande/RJ. Na primeira área de estudo os resultados indicaram ter ocorrido alteração da qualidade natural do ambiente, em decorrência das atividades ali desenvolvidas. No segundo caso não foram observados teores de Sn no ambiente, em concentrações incomuns para regiões marinhas. Por fim, o método analítico desenvolvido foi comparado com a técnica ICP OES e material de referência certificado, mostrando-se eficiente (preciso, exato e robusto) para determinação de Sn em amostras de solo, sedimento e água (concentração total.. / The present study aimed to establish an analytical method to determine tin concentrations in natural samples. It was opted for the coupling of the analytical techniques: atomic fluorescence spectrometry (AFS), hydride generation (HG) and flow injection system (FI). The development of the method considered the AFS operating conditions, the HG technic, the FI system and the digestion procedures of the field samples (solid and liquid). The results showed that the best conditions for the generation of SnH4 were obtained with reductant (NaBH4) 4% (m/v) and acid (HCl) 0,6 mol L-1. The optimized flow rates for the device used in this study were 1,2 mL min-1 of sample, 1,2 mL min-1 of HCl and 1,6 mL min-1 of NaBH4. In these conditions, it was obtained a molar relationship [BH4 −] / [H+] equal to 1,62 for the reactions of stanene. The sample volume injected was 500 μL. The acid volumes defined for the microwave digestion of soil and sediment samples were equal to 3 mL HNO3 + 1 mL HCl. After the development of the analytical method, this procedure was applied to analyze the environmental samples described below. Soil, sediment and water samples were collected in two areas under different anthropogenic activities: processing area of cassiterite in Corumbataí/SP and an area of Ilha Grande Bay/RJ. In the first study area, the obtained data indicated that there was alteration in the natural quality of the environment as a result of the activities developed in that site. In the second area, was not observed Sn content in the environment, in unusual concentrations for marine regions. Finally, the analytical method was compared with the ICP OES technique and certified reference material, and it showed to be efficient (in precision, accuracy and ruggedness) to determine Sn in soil, sediment and water samples (total and dissolved concentrations)
12

Estanho em amostras ambientais por espectrometria de fluorescência atômica (AFS) /

Garcez, Daniel Locoselli. January 2015 (has links)
Orientador: Amauri Antonio Menegário / Banca: Didier Gastmans / Banca: José Roberto Ferreira / Resumo: O presente estudo objetivou estabelecer um método analítico para determinação das concentrações de Sn em amostras naturais. Optou-se pelo acoplamento das técnicas analíticas de espectrometria de fluorescência atômica (AFS), geração de hidretos (HG) e sistema de injeção em fluxo (FI). O desenvolvimento do método considerou a otimização das condições de operação do AFS, da técnica de HG, do sistema FI e dos procedimentos de digestão de amostras ambientais (sólidas e líquidas). Os resultados obtidos demonstraram que as melhores condições para geração de SnH4 foram alcançadas com redutor (NaBH4) 4% (m/v) e ácido (HCl) 0,6 mol L-1. A vazão de injeção de amostra otimizadas foi de 1,2 mL min-1, e as vazões de fluxo de reagentes foram 1,2 mL min-1 de HCl e 1,6 mL min-1 para NaBH4. Nestas condições, foi obtida uma relação molar [BH4 −] / [H+] de 1,62 para as reações de geração de hidreto de Sn. O volume de amostra injetado foi definido como 500 μL. Para as digestões de solo e sedimento em equipamento de micro-ondas, foi definido o uso dos volumes de ácidos 3 mL HNO3 + 1 mL HCl. Após o desenvolvimento do método analítico, este foi aplicado em matrizes ambientais. Para tanto, foram realizadas amostragens de solo, sedimento e água, em duas áreas sob ação antrópica distintas, sendo estas: área de beneficiamento de cassiterita em Corumbataí/SP e área da Baía da Ilha Grande/RJ. Na primeira área de estudo os resultados indicaram ter ocorrido alteração da qualidade natural do ambiente, em decorrência das atividades ali desenvolvidas. No segundo caso não foram observados teores de Sn no ambiente, em concentrações incomuns para regiões marinhas. Por fim, o método analítico desenvolvido foi comparado com a técnica ICP OES e material de referência certificado, mostrando-se eficiente (preciso, exato e robusto) para determinação de Sn em amostras de solo, sedimento e água (concentração total.. / Abstract: The present study aimed to establish an analytical method to determine tin concentrations in natural samples. It was opted for the coupling of the analytical techniques: atomic fluorescence spectrometry (AFS), hydride generation (HG) and flow injection system (FI). The development of the method considered the AFS operating conditions, the HG technic, the FI system and the digestion procedures of the field samples (solid and liquid). The results showed that the best conditions for the generation of SnH4 were obtained with reductant (NaBH4) 4% (m/v) and acid (HCl) 0,6 mol L-1. The optimized flow rates for the device used in this study were 1,2 mL min-1 of sample, 1,2 mL min-1 of HCl and 1,6 mL min-1 of NaBH4. In these conditions, it was obtained a molar relationship [BH4 −] / [H+] equal to 1,62 for the reactions of stanene. The sample volume injected was 500 μL. The acid volumes defined for the microwave digestion of soil and sediment samples were equal to 3 mL HNO3 + 1 mL HCl. After the development of the analytical method, this procedure was applied to analyze the environmental samples described below. Soil, sediment and water samples were collected in two areas under different anthropogenic activities: processing area of cassiterite in Corumbataí/SP and an area of Ilha Grande Bay/RJ. In the first study area, the obtained data indicated that there was alteration in the natural quality of the environment as a result of the activities developed in that site. In the second area, was not observed Sn content in the environment, in unusual concentrations for marine regions. Finally, the analytical method was compared with the ICP OES technique and certified reference material, and it showed to be efficient (in precision, accuracy and ruggedness) to determine Sn in soil, sediment and water samples (total and dissolved concentrations) / Mestre
13

Desenvolvimento de um sistema eletroquímico de análise por injeção em fluxo para detecção de cocaína / Development of an Electrochemical Flow Injection Analysis system for Detection of Cocaine

Oliveira, Laura Siqueira de 17 January 2012 (has links)
O aumento nos índices de criminalidade, na maioria das vezes decorrente de atividades ligadas ao tráfico de drogas, afeta drasticamente a qualidade de vida do ser humano. A análise instrumental de entorpecentes é realizada comumente por métodos cromatográficos, oferecendo limites de detecção (LDs) em torno de 1 ng mL-1. As técnicas analíticas como voltametria, amperometria, potenciometria, dentre outras, assemelham-se às técnicas convencionais de análise, pois além de se mostrarem sensíveis para a análise de traços de substâncias orgânicas e inorgânicas, oferecem vantagens operacionais como a compreensão de mecanismos pato-fisiológicos de várias drogas, dentre elas a cocaína e seus metabólitos. Os eletrodos quimicamente modificados (EQMs) com bases de Schiff (grupos funcionais que contém uma ligação dupla carbono-nitrogênio com o átomo de nitrogênio conectado a um grupo arila ou alquila) desenvolvidos para a determinação de cocaína em amostras de interesse forense podem ser empregados em situação de análise por injeção em fluxo (FIA). Cuja metodologia consiste na inserção de uma alíquota de amostra em um fluido carregador que a transporta do ponto de injeção até a unidade de detecção. Atualmente a análise de cocaína está limitada à dosagem posterior de amostras apreendidas, uma vez que não há nenhum dispositivo portátil para a detecção da mesma em local de crime. Assim, este projeto visa desenvolver uma metodologia voltamétrica, por meio de eletrodos quimicamente modificados com bases de Schiff, e da aplicação dos mesmos em FIA para a detecção de cocaína em amostras de interesse forense. / The increase in crime occurrences, mostly due to activities linked to drug trafficking, dramatically affects the quality of human life. The instrumental analysis of drugs is commonly performed by chromatographic methods, offering limits of detection (LD) around 1 ng mL-1. Analytical techniques such as voltammetry, amperometry, potentiometry, among others, are similar to conventional analysis techniques, as well as prove sensitive for trace analysis of organic and inorganic substances, provide operational advantages as the understanding of pathophysiological mechanisms of several drugs, among them cocaine and its metabolites. The chemically modified electrodes (CMEs) with Schiff bases (functional groups containing a carbon-nitrogen double bond with the nitrogen atom attached to an alkyl or aryl group) developed for the determination of cocaine in samples of forensic interest can be used in situation of flow injection analysis (FIA). The methodology consists of inserting a sample rate of a carrier fluid that carries the point of injection to the detection unit. The analysis is limited to the dosage cocaine samples seized previously, since there is no portable device for detection in the same scene. Thus, this project aims to develop a voltammetric methodology, by means of chemically modified electrodes with Schiff bases, and applying them in the FIA for the detection of cocaine in samples of forensic interest.
14

Desenvolvimento de um sistema eletroquímico de análise por injeção em fluxo para detecção de cocaína / Development of an Electrochemical Flow Injection Analysis system for Detection of Cocaine

Laura Siqueira de Oliveira 17 January 2012 (has links)
O aumento nos índices de criminalidade, na maioria das vezes decorrente de atividades ligadas ao tráfico de drogas, afeta drasticamente a qualidade de vida do ser humano. A análise instrumental de entorpecentes é realizada comumente por métodos cromatográficos, oferecendo limites de detecção (LDs) em torno de 1 ng mL-1. As técnicas analíticas como voltametria, amperometria, potenciometria, dentre outras, assemelham-se às técnicas convencionais de análise, pois além de se mostrarem sensíveis para a análise de traços de substâncias orgânicas e inorgânicas, oferecem vantagens operacionais como a compreensão de mecanismos pato-fisiológicos de várias drogas, dentre elas a cocaína e seus metabólitos. Os eletrodos quimicamente modificados (EQMs) com bases de Schiff (grupos funcionais que contém uma ligação dupla carbono-nitrogênio com o átomo de nitrogênio conectado a um grupo arila ou alquila) desenvolvidos para a determinação de cocaína em amostras de interesse forense podem ser empregados em situação de análise por injeção em fluxo (FIA). Cuja metodologia consiste na inserção de uma alíquota de amostra em um fluido carregador que a transporta do ponto de injeção até a unidade de detecção. Atualmente a análise de cocaína está limitada à dosagem posterior de amostras apreendidas, uma vez que não há nenhum dispositivo portátil para a detecção da mesma em local de crime. Assim, este projeto visa desenvolver uma metodologia voltamétrica, por meio de eletrodos quimicamente modificados com bases de Schiff, e da aplicação dos mesmos em FIA para a detecção de cocaína em amostras de interesse forense. / The increase in crime occurrences, mostly due to activities linked to drug trafficking, dramatically affects the quality of human life. The instrumental analysis of drugs is commonly performed by chromatographic methods, offering limits of detection (LD) around 1 ng mL-1. Analytical techniques such as voltammetry, amperometry, potentiometry, among others, are similar to conventional analysis techniques, as well as prove sensitive for trace analysis of organic and inorganic substances, provide operational advantages as the understanding of pathophysiological mechanisms of several drugs, among them cocaine and its metabolites. The chemically modified electrodes (CMEs) with Schiff bases (functional groups containing a carbon-nitrogen double bond with the nitrogen atom attached to an alkyl or aryl group) developed for the determination of cocaine in samples of forensic interest can be used in situation of flow injection analysis (FIA). The methodology consists of inserting a sample rate of a carrier fluid that carries the point of injection to the detection unit. The analysis is limited to the dosage cocaine samples seized previously, since there is no portable device for detection in the same scene. Thus, this project aims to develop a voltammetric methodology, by means of chemically modified electrodes with Schiff bases, and applying them in the FIA for the detection of cocaine in samples of forensic interest.