Spelling suggestions: "subject:"analytisk modell"" "subject:"enanalytisk modell""
1 |
Micro Assembly for Radio Frequency Electronics : Characterization of Bond WiresChen, Youjie January 2019 (has links)
Due to the increasing number of components involved in Radio Frequency design, integration and packaging become an important topic of developing power-efficient and cost-effective solutions. Furthermore, interconnections are a key factor in such a topic because they are heavily used in Radio Frequency engineering, especially in the Fifth Generation. Among the interconnections, bond wires are one of the most commonly used.In micro assembly design, it is crucial to understand and model the behavior of each component, including interconnections. Radio Frequency engineers usually use the bond wire models in the software directly without questioning if the model actually has the same behavior as the fabricated one. Therefore, how to accurately model and characterize the bond wires becomes valuable, and furthermore, how the physical dimensions affect the transmission performance. This Master’s thesis project aims to solve this problem by building simple models for single bond wire and double bond wires with coupling, and verifying them by electromagnetic simulation and measurement.The project has built bond wire models in Matlab and in electromagnetic simulators NI AWR and ANSYS HFSS. The actual test structures are also fabricated using the bonding machine, and measured by vector network analyzer. A sufficient amount of data has been collected from these sources and then analyzed. The proposed analytical model of bond wires is valid after comparing its results with those from simulation and measurement. In addition, the effect of the loop height and separation distance on the transmission performance is studied and has a well verified conclusion.This thesis work will be helpful to Radio Frequency engineers, who use bond wires in the micro assembly of their design. They would be able to characterize the bond wires more accurately and adjust the physical dimensions in order to achieve the desired performance. / På grund av det ökande antalet komponenter i radiofrekvensdesign, integration och förpackning blivit ett viktigt ämne för att utveckla energieffektiva och kostnadseffektiva lösningar. Sammankopplingar är en nyckelfaktor i ett sådant ämne, eftersom de är starkt används i radiofrekvensteknik. Bland dem, bondtrådar är en av de vanligaste.Det är viktigt att förstå och modellera beteendet hos varje komponent. Därför hur att noggrant modellera och karakterisera bondtrådarna blir ett värdefullt problem, och dessutom, hur de fysiska dimensionerna påverkar överföringsprestanda.Projektet har byggt bondtrådsmodeller i Matlab och i elektromagnetiska simulatorer NI AWR och ANSYS HFSS. De faktiska teststrukturerna tillverkas också med hjälp av bindningsmaskinen och mäts av vektornätverksanalysatorn. Den föreslagna analysmodellen för bindningstrådar är giltig efter att ha jämfört dess resultat med dem från simulering och mätning. Dessutom studeras effekten av slinghöjden och separationsavståndet på transmissionens prestanda och har en väl verifierad slutsats.
|
2 |
Förhindrande av frostbildning i plattvärmeväxlare via variabel förvärmd uteluftSvedman, Mathias January 2019 (has links)
Denna studie har undersökt om förvärmning av luft är en bra metod för att undvika frostbildning i motströmsplattvärmeväxlare i luftbehandlingsaggregat. Frostbildning i värmeväxlare för ventilation är ett problem i kalla klimat och sänker den återvunna energimängden när potentialen för energiåtervinning är som högst. Tidigare forskning i området har utförts för att bland annat: 1) Definiera säkra förhållanden utan frostbildning i värmeväxlare med laminär luftströmning. 2) Jämföra olika frostkontrollstrategier. 3) Analysera frostbildningens egenskaper och effekt på värmeväxlare i ventilation. Att forskningen inte är entydig för vilken frostkontrollstrategi som är bäst belyser vikten av detta arbete. I en fallstudie kvantifieras empiriska värmeöverföringskoefficienter som används i en analytisk modell som förutspår energianvändningen för luftvärmning under olika driftfall för ett luftbehandlingsaggregat. Värmeöverföringskoefficienterna tas fram genom mätningar i ett luftbehandlingsaggregat lokaliserat i ett flerbostadshus. Mätobjektet har ett installerat värmebatteri före värmeväxlaren vilket värmer inkommande uteluft till konstant lufttemperatur. Tillverkaren proklamerar att det sker turbulent luftströmning i den studerade värmeväxlaren. Vid olika lufthastigheter ändras värmeöverföringskoefficienten mer vid turbulent strömning än vid laminär strömning. Att olika lufthastigheter har betydlig inverkan på värmeöverföringskoefficienten överensstämmer med resultatet från mätningarna. Effektiviteten av den aktuella styrningen av förvärmaren har granskats och brister har upptäckts. En ny optimerad styrning föreslås för frostfri drift och minimerad energianvändning. Den optimerade styrningen jämförs sedan med en vanlig avfrostningsmetod och utförs med hjälp av flödesbalansstatistik från ett aggregat med sektionsavfrostningsstyrning. Resultatet visar att förvärmning av luft för frostfri drift använder mindre energi än vid sektionsavfrostningsstyrning. Den föreslagna styrningen innebär att bypass-spjället öppnas då förvärmaren går på full effekt. Detta för att förhindra påfrostning vid extrema utetemperaturer, då förvärmaren inte ger tillräcklig effekt för att undvika påfrostning. Den föreslagna styrningen regleras utifrån daggpunkten, temperaturen på tilluften innan värmeväxlaren och temperaturen på avluften. Den framtagna värmeöverföringskoefficienten i studien tar inte i beaktning ökad koefficient under fuktiga förhållanden då daggpunkten i frånluften är över fryspunkten och det sker kondens. En framtida studie kan hitta värmeöverföringskoefficienter som förutspår yttemperaturen under kondensutfällning då daggpunkten är över 0°C vilket ger medel för att ta fram en ännu mera energieffektiv styrning. Detta kan utföras genom mätning i ett luftbehandlingsaggregat med hög temperaturverkningsgrad placerat i en fuktig miljö. / This study has analysed if preheating of air is a good method to prevent frost formation in a counter flow plate heat exchanger used in Air Handling Units. Frosting in heat exchangers used in AHU-systems is a problem in cold climates and lowers the energy recovery when its potential is the highest. Previous research has been done to 1) Define safe operating conditions without frost formation in heat exchangers with laminar flow. 2) Compare different frost control strategies. 3) Analyse frost formation properties and its effects on heat exchangers in AHU-systems. That the research is not unambiguous for which frost control method is the best highlights the importance of this work. Empirical heat transfer coefficients are quantified in this study and are used in the creation of an analytical model of a counter flow heat exchanger that predicts the energy use for heating the air at different operating modes. The heat transfer coefficients are produced by measurements in an AHU-systems located in an apartment building. The AHU has an installed air heater before the heat exchanger which heats the outdoor inlet air to constant temperature. The manufacturer of the AHU-system proclaims turbulent flow in the heat exchanger. Change of airflow has greater impact on the heat transfer coefficients during turbulent flow compared to laminar flow conditions. This is also derived from the results of the measurements. The effectiveness of the current control system is analyzed, and flaws are discovered. A new control system is therefore proposed for frost free operation and higher energy efficiency. The proposed control system is compared to a frequently used frost control system which uses bypass-dampers to redirect the inlet air to the reheater, to let the warm air stream melt formed frost on the warm air side. This comparison is accomplished by analyzing the usage of the bypass-dampers during different outdoor temperatures in a comparable AHU-system that have the mentioned frost control method. The results show that preheating of inlet air for frost free operation uses less energy than usage of the bypass-dampers to melt formed frost on the warm air side. The proposed control system needs the bypass-dampers to be used when the preheater is on full operation to prevent frost formation at extreme outdoor temperatures when the preheating may not be enough. The proposed control system is regulated by the dewpoint and the temperatures of the exhaust air stream and the supply air stream. The derived heat transfer coefficient that is used to predict the plate-temperature take no account for condensation on the warm air side during humid conditions when the dew point is above the freezing point. Future studies can derive the heat transfer coefficient during condensation which will improve the prediction of the plate-temperature. This would make the system more energy efficient during humid air conditions. This can be done by measurements in an AHU-system with high temperature efficiency placed in a humid environment.
|
3 |
Capcal for small roundabouts : Current status and improvements / Capcal för små cirkulationsplatser : Nuvarande situation och förbättringarLinse, Leif January 2010 (has links)
Questions have been raised regarding how good Capcal works for roundabouts with a weaving length smaller than 25 meters and if Capcal would work for weaving lengths lower than the 16 meters that is the lower limit in the current model. In this thesis, two possible improvements has been developed and tested on five roundabouts with a weaving length less than 25 meters. Work has been done to build alternative gap acceptance models ranging from removal of the 16-meter limit through re-estimation of the current model to a completely new model. In this thesis a new sub model has been introduced that take into account the uncertainty of if circulating vehicles will exit or continue to circulate. These sub models have been combined in 29 different ways including the current Capcal model configuration and have been tested with five different roundabouts. The conflict delay, which is caused by interaction with other vehicles, has been used to compare the model results with delay observations from video captures of the roundabouts. Out of all model configurations, the original Capcal 3.3 model had the lowest difference in average between the model result and the observations. If the 16-meter weaving length restriction in the original model is removed, almost the same results are obtained as with the restriction. While none of the model configurations improved the model fit, no configuration could be statistically be rejected. In the results of individual roundabouts, there were differences between the model and observations of up to 50%. This shows that while this thesis could not find any improvements of Capcal, there is a potential for future work to develop improvements of the roundabout model. / I nuläget tillåter Capcal att växlingssträckor ner till 16 meter modelleras, men i dataunderlaget som användes vid skapandet av nuvarande modell finns endast med en cirkulationsplats under 25 meter. Det har lyfts frågetecken kring huruvida Capcal ger bra resultat för cirkulationsplatser med en växlingssträcka på mindre än 25 meter samt huruvida modellens nedre gräns på 16 meter skulle kunna tas bort. I detta examensarbete har två olika möjligheter att förbättra modellen testats på fem olika cirkulationsplatser med växlingssträcka kortare än 25 meter. I arbetet har det ingått att ta fram alternativa gap-acceptance-modeller vilka sträcker sig från att enbart ta bort 16-metersgränsen via en nyestimering av Capcals modell till en helt ny modell. Därtill har en ny submodell skapats som tar hänsyn till den osäkerhet som uppstår kring huruvida cirkulerande fordon kommer att köra ur cirkulationen vid en utfart eller fortsätta cirkulera. De utvecklade submodellerna samt nuvarande Capcal modell har kombinerats i 29 olika kombinationer. Dessa 29 kombinationer har för varje av de fem studerade cirkulationsplatserna testats mot observationer från respektive cirkulationsplats. Konfliktfördröjningen, vilket är fördröjning på grund av interaktion med andra fordon, har använts för att jämföra Capcal-resultaten och observationerna. Av alla modellkonfigurationer så gav nuvarande Capcal 3.3-modell lägst medelskillnad mellan modellresultat och observationer. Om 16-meter-restriktionen i nuvarande Capcal-modell tas bort, så fås i stort sett samma resultat. Ingen av de studerade modell-förändringarna gav en bättre passning mellan modell och verklighet i medel, men ingen förändring kunde förkastas ur statistisk synvinkel. Det var dock stora variationer i resultaten för enskilda cirkulationsplatser med upp till 50% skillnad mellan modellens resultat och observerade värden. Detta visar på att även om detta examensarbete inte lyckades hitta några förbättringar av Capcal, så finns det potential för framtida arbete att ta fram förbättringar av cirkulationsplatsmodellen i Capcal.
|
4 |
Study of Analytical Models for Harmonic Losses Calculations in Traction Induction MotorsMaroteaux, Anaïs January 2016 (has links)
This Master Thesis deals with the study of analytical and finite-element (FE) models for calculation of losses in traction induction motors. Motors are fed through inverters for this type of application. Therefore, both fundamental and harmonic losses are considered. The study is done with one particular motor and one initial analytical model. In order to validate the model and improve it, a FE model is developed with the tool FLUX 2D. Several chosen operating points with different modulation patterns are simulated both with FE and analytical models and results are compared. Stator and rotor Joule losses are studied first. A model to calculate stator Joule losses at strand level is proposed as an improvement to the current analytical model. Then iron losses, both in stator and rotor, are calculated. Two different computations methods with data extraction from FE are studied: the Bertotti model and a recently developed method called MVPRS in the report. It is based on a mathematical model for curve fitting of the core loss material data. Results with the two methods are compared with the ones from ana-lytical model. Finally total fundamental and harmonic losses are compared with measurements and conclusions are drawn on the quality and accuracy of the analytical model. / Detta examensarbete handlar om analytiska och Finita Element (FE) modeller för beräkning av förluster i asynkronmotorer för traktion. Motorer matas genom växelriktare för denna typ av applikation. Därför är det nödvändigt att både grundläggande och harmoniska förluster beaktas. Studien görs för en särskild motor och en redan existerande analytisk modell. För att validera modellen och förbättra den, utvecklats en FE modell med verktyget FLUX 2D. Flera arbetspunkter med olika moduleringsmönster simuleras både med FE och analytiska modeller och resultaten jämförs. Först studeras stator och rotor Joule förluster. En modell för att beräkna stator Joule förluster i varje ledare föreslås som en förbättring av den nuvarande analytiska modellen. Sedan beräknas järnförluster, både i stator och rotor, beräknas. Två olika metoder baserad på flödestäthet variationer i tid och rum från FE simuleringar studeras med Bertottis modell och en nyutvecklad metod som kallas MVPRS. Den är baserat på en matematisk modell för kurvanpassning av materialet förlust data. Resultaten med de två metoderna jämförs med de från analytiska modellen. Slutligen jämförs totala fundamentala och harmoniska förluster med mätningar och slutsatser dras om kvalitet och noggrannhet av analytiska modellen.
|
Page generated in 0.0518 seconds