• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 179
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 182
  • 67
  • 54
  • 53
  • 47
  • 41
  • 37
  • 30
  • 25
  • 25
  • 25
  • 22
  • 21
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Avaliação das alterações dentoesqueléticas de jovens com má oclusão de Classe II tratados com aparelho distalizador First Class Modificado, utilizando modelos digitais e análise cefalométrica / Evaluating of dental and skeletal changes in young Class II malocclusion treated with modified First Class distalizer using digital models and cephalometric analysis

Dias, Fernando Henrique Trigueiro 25 March 2013 (has links)
O objetivo deste estudo foi avaliar as alterações dentoesqueléticas, tegumentares e transversais do arco superior de jovens com má oclusão de Classe II predominantemente dentária, tratados com o distalizador First Class em ancoragem convencional e esquelética. A amostra foi composta por 30 pacientes divididos em três grupos com 10 pacientes cada, nomeados G1 (ancoragem convencional), G2 (ancoragem esquelética) e G3 (modificado com ancoragem squelética). As telerradiografias laterais, para todos os grupos, e os modelos de documentação, para G2 e G3, foram obtidos antes e após a distalização dos molares sendo posteriormente digitalizados para a realização da análise cefalométrica e de modelos digitais. Os dados foram analisados por meio dos testes t pareado, para verificar as alterações produzidas em um mesmo grupo nos tempos inicial e pós distalização, e ANOVA seguido do Teste de Tukey para verificar as diferenças entre os grupos, para dados com distribuição não normal foram utilizados os testes de Wilcoxon e Kruskal-Wallis. O tempo médio de tratamento foi de 4,62 meses para o G1; 5,41 meses para o G2 e 3,91 meses para o G3, não havendo diferença entre eles. A análise dos primeiros molares demonstrou que todos os grupos presentaram alterações dentárias significantes na angulação (G1= -8,42o; G2= -5,98o; G3= - 6,12o), apenas os grupos G1 e G3 (G1= -1,63 mm; G2= -1,31 mm; G3= - 1,91 mm) apresentaram alterações significantes na distalização e não foram detectadas alterações verticais (G1= -1,63 mm; G2= -1,31 mm; G3= -1,91 mm). A perda de ancoragem anterior foi significantemente menor para os valores angulares no G3 demonstrando uma suave vestibularização dos incisivos centrais (G1= 4,76o; G2= 4,49o; G3= 0,64o) e menor angulação mesial dos segundos pré-molares (G1= 6,69o; G2= 10,29o; G3= 3,55o), não havendo diferenças entre os grupos para os componentes lineares horizontais (G1= 1,77 mm; G2= 1,72 mm; G3= 1,05 mm) e verticais (G1= -0,17 mm; G2= -0,02 mm; G3= 0,31mm) dos incisivos e lineares horizontais (G1= 2,88 mm; G2= 3,19 mm; G3= 2,43 mm) e verticais (G1= 0,37 mm; G2= 0,63 mm; G3= 0,95 mm) dos segundos pré-molares. A distalização promoveu ainda um aumento mais acentuado da AFAI para o G3 (G1= 0,49 mm; G2= 1,20 mm; G3= 1,71 mm) e uma menor alteração do ANL também para o G3 (G1= -4,71o; G2= -2,82º; G3= 0,42o). A análise dos modelos digitais demonstrou diferença significante apenas para a distância entre segundos pré-molares (G2= -2,14 mm; G3= -1,10 mm). Todos os aparelhos estudados são eficazes para realizar a correção da relação molar promovendo uma perda de ancoragem anterior, sendo este efeito indesejado menor para o distalizador First Class modificado associado à ancoragem esquelética. / The aim of this study was to evaluate the dentoskeletal, soft tissue and maxillary transverse dimensions changes in youngsters with dental Class II malocclusion treated with First Class distalizer in skeletal and conventional anchorage. Thirty patients were included and divided in three groups of 10 patients each, named G1 (conventional anchorage), G2 (skeletal anchorage) and G3 (modified First Class with skeletal anchorage). Lateral radiographs, for all groups, and dental casts, for G2 and G3, were obtained before and after molar distalization and subsequently scanned to perform cephalometric and digital models analysis. Data were analyzed using paired t tests to verify the same group changes at initial and after distalization time, and ANOVA followed by Tukey test to detect differences between groups, for data with non-normal distribution were used Wilcoxon and Kruskal-Wallis tests. No difference was found in treatment time (G1= 4.62 months, G2= 5.41 months, G3= 3.91 months). First molars analysis showed that all groups had significant dental angulation changes (G1= -8.42o, G2= -5.98o, G3= -6.12°), G1 an d G3 showed significant distalization changes (G1= -1.63 mm, G2= -1.31 mm; G3= - 1.91 mm) and no vertical changes were detected (G1= -1.63 mm, G2= -1.31 mm, G3= -1.91 mm). Anchorage loss was significantly smaller to the G3 angular measurements, demonstrating a little incisors vestibularization (G1= 4.76o, G2= 4.49o, G3= 0.64o) and little second premolars mesial angulation (G1= 6.69o, G2= 10.29o, G3= 3.55o), with no horizontal linear changes (G1= 1.77 mm, G2= 1.72 mm, G3= 1.05 mm) and no vertical linear differences between groups (G1= -0.17 mm , G2= -0.02 mm, G3= 0.31 mm) of incisors and horizontal linear (G1= 2.88 mm, G2= 3.19 mm, G3= 2,43 mm) and vertical (G1= 0.37 mm, G2= 0.63 mm, G3= 0.95 mm) of the second premolars. Distalization increased the LAFH to G3 (G1= 0.49 mm, G2= 1.20 mm, G3= 1.71 mm) and also promoted changes in G3 NLA (G1= -4.71o, G2= -2.82o, G3= 0.42°). Digital models analysis showed a significant difference only for the second premolars transverse dimension (G2 = -2.14 mm; G3= -1.10 mm). All devices studied were effective to perform the molar relationship correction, resulting an anchorage loss, this unwanted effect was lesser with modified First Class distalizer with skeletal anchorage.
102

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Roberto Bombonatti 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
103

Avaliação das alterações dentoesqueléticas de jovens com má oclusão de Classe II tratados com aparelho distalizador First Class Modificado, utilizando modelos digitais e análise cefalométrica / Evaluating of dental and skeletal changes in young Class II malocclusion treated with modified First Class distalizer using digital models and cephalometric analysis

Fernando Henrique Trigueiro Dias 25 March 2013 (has links)
O objetivo deste estudo foi avaliar as alterações dentoesqueléticas, tegumentares e transversais do arco superior de jovens com má oclusão de Classe II predominantemente dentária, tratados com o distalizador First Class em ancoragem convencional e esquelética. A amostra foi composta por 30 pacientes divididos em três grupos com 10 pacientes cada, nomeados G1 (ancoragem convencional), G2 (ancoragem esquelética) e G3 (modificado com ancoragem squelética). As telerradiografias laterais, para todos os grupos, e os modelos de documentação, para G2 e G3, foram obtidos antes e após a distalização dos molares sendo posteriormente digitalizados para a realização da análise cefalométrica e de modelos digitais. Os dados foram analisados por meio dos testes t pareado, para verificar as alterações produzidas em um mesmo grupo nos tempos inicial e pós distalização, e ANOVA seguido do Teste de Tukey para verificar as diferenças entre os grupos, para dados com distribuição não normal foram utilizados os testes de Wilcoxon e Kruskal-Wallis. O tempo médio de tratamento foi de 4,62 meses para o G1; 5,41 meses para o G2 e 3,91 meses para o G3, não havendo diferença entre eles. A análise dos primeiros molares demonstrou que todos os grupos presentaram alterações dentárias significantes na angulação (G1= -8,42o; G2= -5,98o; G3= - 6,12o), apenas os grupos G1 e G3 (G1= -1,63 mm; G2= -1,31 mm; G3= - 1,91 mm) apresentaram alterações significantes na distalização e não foram detectadas alterações verticais (G1= -1,63 mm; G2= -1,31 mm; G3= -1,91 mm). A perda de ancoragem anterior foi significantemente menor para os valores angulares no G3 demonstrando uma suave vestibularização dos incisivos centrais (G1= 4,76o; G2= 4,49o; G3= 0,64o) e menor angulação mesial dos segundos pré-molares (G1= 6,69o; G2= 10,29o; G3= 3,55o), não havendo diferenças entre os grupos para os componentes lineares horizontais (G1= 1,77 mm; G2= 1,72 mm; G3= 1,05 mm) e verticais (G1= -0,17 mm; G2= -0,02 mm; G3= 0,31mm) dos incisivos e lineares horizontais (G1= 2,88 mm; G2= 3,19 mm; G3= 2,43 mm) e verticais (G1= 0,37 mm; G2= 0,63 mm; G3= 0,95 mm) dos segundos pré-molares. A distalização promoveu ainda um aumento mais acentuado da AFAI para o G3 (G1= 0,49 mm; G2= 1,20 mm; G3= 1,71 mm) e uma menor alteração do ANL também para o G3 (G1= -4,71o; G2= -2,82º; G3= 0,42o). A análise dos modelos digitais demonstrou diferença significante apenas para a distância entre segundos pré-molares (G2= -2,14 mm; G3= -1,10 mm). Todos os aparelhos estudados são eficazes para realizar a correção da relação molar promovendo uma perda de ancoragem anterior, sendo este efeito indesejado menor para o distalizador First Class modificado associado à ancoragem esquelética. / The aim of this study was to evaluate the dentoskeletal, soft tissue and maxillary transverse dimensions changes in youngsters with dental Class II malocclusion treated with First Class distalizer in skeletal and conventional anchorage. Thirty patients were included and divided in three groups of 10 patients each, named G1 (conventional anchorage), G2 (skeletal anchorage) and G3 (modified First Class with skeletal anchorage). Lateral radiographs, for all groups, and dental casts, for G2 and G3, were obtained before and after molar distalization and subsequently scanned to perform cephalometric and digital models analysis. Data were analyzed using paired t tests to verify the same group changes at initial and after distalization time, and ANOVA followed by Tukey test to detect differences between groups, for data with non-normal distribution were used Wilcoxon and Kruskal-Wallis tests. No difference was found in treatment time (G1= 4.62 months, G2= 5.41 months, G3= 3.91 months). First molars analysis showed that all groups had significant dental angulation changes (G1= -8.42o, G2= -5.98o, G3= -6.12°), G1 an d G3 showed significant distalization changes (G1= -1.63 mm, G2= -1.31 mm; G3= - 1.91 mm) and no vertical changes were detected (G1= -1.63 mm, G2= -1.31 mm, G3= -1.91 mm). Anchorage loss was significantly smaller to the G3 angular measurements, demonstrating a little incisors vestibularization (G1= 4.76o, G2= 4.49o, G3= 0.64o) and little second premolars mesial angulation (G1= 6.69o, G2= 10.29o, G3= 3.55o), with no horizontal linear changes (G1= 1.77 mm, G2= 1.72 mm, G3= 1.05 mm) and no vertical linear differences between groups (G1= -0.17 mm , G2= -0.02 mm, G3= 0.31 mm) of incisors and horizontal linear (G1= 2.88 mm, G2= 3.19 mm, G3= 2,43 mm) and vertical (G1= 0.37 mm, G2= 0.63 mm, G3= 0.95 mm) of the second premolars. Distalization increased the LAFH to G3 (G1= 0.49 mm, G2= 1.20 mm, G3= 1.71 mm) and also promoted changes in G3 NLA (G1= -4.71o, G2= -2.82o, G3= 0.42°). Digital models analysis showed a significant difference only for the second premolars transverse dimension (G2 = -2.14 mm; G3= -1.10 mm). All devices studied were effective to perform the molar relationship correction, resulting an anchorage loss, this unwanted effect was lesser with modified First Class distalizer with skeletal anchorage.
104

Avaliação cefalométrica comparativa do tratamento da má oclusão de Classe II com o distalizador first class em ancoragem convencional e esquelética e aparelho extrabucal cervical seguidos de aparelho fixo / Comparative cephalometric evaluation of Class II malocclusion treatment with First Class distalizer in conventional and skeletal anchorage and cervical headgear followed by fixed orthodontic appliance

Grec, Roberto Henrique da Costa 06 April 2015 (has links)
O objetivo deste estudo longitudinal foi comparar as alterações dentoesqueléticas e tegumentares de jovens com má oclusão de Classe II não tratados e tratados com distalizador First Class em ancoragem convencional ou esquelética, ou com o aparelho extrabucal cervical (AEB), seguidos do aparelho fixo. A amostra foi composta por 44 pacientes com má oclusão de classe II e divididos em quatro grupos de 11 cada: pacientes tratados com distalizador First Class com ancoragem convencional no botão de Nance (G1), tratados com distalizador First Class com ancoragem esquelética apoiado em 2 mini-implantes no palato (G2), tratados com o aparelho extrabucal (AEB) (G3) e o grupo controle, com pacientes não tratados (G0). Foram obtidas as telerradiografias ao início (Ti) e final (Tf) do tratamento para a realização das análises cefalométricas e avaliação das alterações dentárias, esqueléticas e tegumentares e compará-los com o grupo controle (G0). A análise estatística foi realizada pelo teste t pareado com a finalidade de verificar as alterações ocorridas dentro de um mesmo grupo e pelo teste ANOVA a um critério e teste de Tukey para verificar as diferenças entre os grupos. Observou-se restrição e redirecionamento do crescimento maxilar ao final do tratamento no G1 e G3. Os efeitos esqueléticos na mandíbula só foram significantes no G0. As medidas da relação maxilomandibular diminuíram significantemente no G1 e G3 com significante diminuição das medidas que avaliaram o perfil tegumentar. Quanto ao componente vertical todas as medidas aumentaram no G3. Os primeiros molares superiores angularam distalmente no G2 e os inferiores mesialmente no G3. Os quatro grupos apresentaram extrusão dos dentes superiores e inferiores. Os três grupos experimentais apresentaram diminuição significante nas relações dentárias (relação molar, trespasse horizontal e vertical). Conclui-se que os grupos experimentais corrigiram a má colusão de Classe II de maneira satisfatória, sendo que o uso do AEB mostrou efeitos esqueléticos e dentários na correção e os grupos com distalizadores somente efeitos dentários. O tempo de tratamento no grupo com AEB foi significantemente menor. / The aim of this prospective study was to compare the dental, skeletal and soft tissue changes in youngsters with Class II malocclusion untreated and treated with First Class distalizer in conventional or skeletal achorage or with cervical headgear followed by fixed orthodontic appliances. The sample consisted of 44 patients with Class II malocclusion and divided into four groups of 11: patients treated with First Class distalizer with conventional anchorage (Nance button)(G1), treated with First Class distalizer with skeletal anchorage supported in two palatal mini-implants (G2), treated with cervical headgear (G3) and follow-up group with untreated patients (G0). Lateral cephalometrics radiographs were taken before treatment and after treatment in order to cephalometric analysis and evaluate the dental, skeletal and soft tissue changes and to compare with follow-up group (G0). Statistical analysis was performed by dependent t test to verify the changes occurred in the same group and by one-way ANOVA and Tukey test to verify the changes occurred between the groups. It was observed restriction and redirection of maxillary growth after treatment in G1 and G3. Mandibular skeletal effects were significant in G0. The values of skeletal maxilomandibular relationship decreased significantly in G1 and G3 with significant decrease of measurements that evaluated soft facial profile. All measurements of vertical component increased in G3. Maxillary first molars were distal tipping in G2 and lower first molars were mesial tipping in G3. The four groups showed extrusion in the upper and lower teeth. The three experimental groups showed significant decreased in the molar relationship, overjet and overbite. It concluded that experimental groups corrected the Class II malocclusion efficiently, cervical headgear showed skeletal and dental effects and the groups with distalizers showed only dental effects. The mean treatment period was significant lower with cervical headgear.
105

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Bombonatti, Roberto 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
106

Estudo comparativo de diferentes mini-implantes utilizados para mesialização de segundo molar inferior : análise por elementos finitos 3d /

Lisboa, Juliana da Costa. January 2018 (has links)
Orientador: Fellippo Ramos Verri / Coorientador: João Maurício Ferraz da Silva / Banca: Fellippo Ramos Verri / Banca: José Benedito Oliveira Amorim / Banca: Virgílio Vilas Boas Fernandes Junior / Resumo: A perda do primeiro molar é uma situação comum na rotina do consultório e com isso surgem alternativas de tratamento para reabilitação, sendo uma delas, o fechamento de espaço através da mesialização do segundo molar. O uso de mini- implante proporciona ancoragem máxima, costuma ser bem tolerado pelo paciente e se destaca pela facilidade de instalação e remoção, apresentando dessa maneira desempenho clínico bastante favorável. O objetivo desse estudo foi analisar a distribuição de tensões em modelo que simula a mesialização de molar inferior utilizando diferentes tipos de mini-implantes. Embasado no método dos elementos finitos foi obtido modelo ósseo de mandíbula por recomposição de uma tomografia computadorizada realizada pelo software Invesalius (CTI, São Paulo, Brasil). O desenho do segundo molar foi obtido por técnica de recomposição tomográfica. Elementos de ancoragem auto-perfurantes da marca Neodent e também auto-rosqueantes da marca Titanium Fix foram desenhados e modelados por ferramenta de revolução do perfil desenhado no software Rhinoceros 3D, inseridos ao bloco ósseo e então submetidos a cargas de 200 cN. Os resultados foram calculados e analisados pelo programa Ansys 17.0 para verificação por meio da análise de mapas de deslocamento e tensões máximas principais, principalmente do osso cortical e indicaram que, dentro do modelo experimental, o ligamento periodontal apresentou valores baixos de tensão máxima principal, porém dentro dos valores fisiológicos para p... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The loss of the first molar is a common situation in the routine of the dentist and with this treatment alternatives for rehabilitation arises, one of them being the closure of space through the mesialization of the second molar. The use of mini-implants provides maximum anchorage, is well tolerated by the patient and stands out for ease installation and removal, thus presenting a very favorable clinical performance. The objective of this study was to analyze the stress distribution in a model that simulates the inferior molar mesialization using different types of mini- implants. Based on the finite element method, a mandible bone model was obtained by recomposing a computerized tomography performed by invesalius software (CTI, São Paulo, Brazil). The second molar design was obtained by a technique similar to the tomographic recomposition. Neodent self-piercing anchoring elements and also Titanium Fix self-piercing anchors were designed and modeled by a revolution tool in the Rhinoceros 3D software, inserted into the bone block and then subjected to loads of up to 200 cN. The results were calculated and analyzed by the Ansys 17.0 program for verification by means of the analysis of displacement maps and main maximum stresses, mainly of the cortical bone and indicated that, within the experimental model, the periodontal ligament presented low values of main maximum tension, however within the physiological values to provide the movement, with visualization of areas of compres... (Complete abstract click electronic access below) / Mestre
107

Desenvolvimento de método e ferramenta para aplicação submarina de clamps de reparo de dutos ou proteção de sistemas de monitoramento

Bertoldi, Evandro January 2018 (has links)
O escoamento entre o poço marítimo e a unidade flutuante é realizado através de dutos definidos como risers. Os risers flexíveis são compostos por camadas intercaladas de diferentes materiais, como aço e polietileno, o qual cada camada possui uma função. Os mecanismos de falha mais reportados são referentes a danos na camada externa polimérica, o que leva à exposição de suas armaduras metálicas ao meio externo. Os risers rígidos são dutos fabricados normalmente em aço, formados por segmentos de dutos unidos por soldas, onde a causa de dano mais frequente é a corrosão. Tem-se como objetivo nesta dissertação, o projeto e desenvolvimento de uma ferramenta e de um método para operações submarinas em risers. A ferramenta deverá ser capaz de aplicar de forma automática, um clamp bipartido no reparo da camada externa polimérica de risers flexíveis, ou acoplar sistemas de monitoramento em risers rígidos. Já o método, deverá permitir a sua aplicação tanto no reparo quanto na proteção do sistema de monitoramento. Para isto, realizou-se uma revisão bibliográfica a fim de obter uma melhor compreensão sobre o tema estudado. Desenvolveu-se o projeto do método e da ferramenta, e, posteriormente, construiu-se o protótipo para a realização de testes de funcionamento em um duto rígido Por último, através de ensaios hidrostáticos de pressão interna e externa, realizaram-se ensaios para avaliação do comportamento do método aplicado em um duto rígido. Os ensaios comprovaram a eficácia do clamp quando aplicado em ambientes submarinos em grandes profundidades, porém apresentou vazamentos nos ensaios de pressão interna e externa. A resina epóxi utilizada não garantiu a estanqueidade, possivelmente devido a sua alta rigidez, aderência ineficaz em superfícies metálicas, ou presença de vazios ou porosidades. O ensaio de pressão interna indicou que as deformações não ultrapassaram o regime elástico tanto do duto quanto do clamp até aproximadamente 182 bar de pressão. No regime elástico, o ensaio apresentou deformações menores no clamp em relação ao duto, possivelmente porque a resina acabou absorvendo as deformações. O método demonstrou ser eficiente como recipiente para a resina, e também permitiu a montagem e fixação de um colar de sensores no seu interior. Os testes de funcionamento mostraram que a ferramenta projetada e construída mostrou-se adequada para a aplicação automática de um clamp bipartido em risers, e o método mostrou-se adequado para sua aplicação em risers, tanto no reparo quanto na proteção do sistema de monitoramento. / The drain between the maritime oil well and the floating unit is made trough pipes, which is defined as risers. The flexible risers are composed by alternate layers from different materials as steel and polyethylene, each layer has its function. The failure mechanisms more reported are referent to the damage in the external polymeric layer which leads to the exposition of the metal armature to the outside. The rigid risers are pipes usually fabricated in steel made by ducts segments connect by spot welding, where the most common damage is corrosion. This essay aims to project and create a tool and a method for submarine operations in risers. The tool must be able to apply, in an automatic way, a bipartite clamp in the repair of the flexible rises in external polymeric layer or to attach monitoring systems to the rigid risers. The method must allow its application in the repair as much as the monitoring system protection. For this, it was made a bibliographic review to obtain a better comprehension from the studied theme. A project from the method and a tool were developed, later a prototype was built to make the operation tests in a rigid pipe. At last, by internal and external pressure hydrostatic trials, were made tests to evaluate the behavior of the method applied in a rigid pipe The trials proved the efficiency of the clamps when applied in submarine environments and in depth; however there were leaks in the internal and external pressure tests. The Epóxi resin did not guarantee the leak-tightness, possible due to its hardness, ineffective adherence in metal surfaces or presence of gaps and porosities. The internal pressure trial indicated that the deformations did not exceed the elastic regime in the pipe as in the clamp until, about 182 pressure bar. In the elastic regime, the trial presented minor deformation in the clamps related to the pipe possibly, because the resin absorbed the deformation. The method has proven efficient as recipient for the resin and also allowed the assembly and fixation of a sensor collar in its interior. The operation tests showed that the designed and built tool is proper for an automatic bipartite clamp application in risers and the method has proven proper for its application in risers in repair as much as monitoring system protection.
108

Avaliação das alterações nos tecidos moles, do tempo de retração e da movimentação de incisivos, caninos e molares em casos de extrações de pré-molares /

Schneider, Patricia Pigato. January 2019 (has links)
Orientador: Luis Gonzaga Gandini Junior / Resumo: Os fechamentos dos espaços das extrações pode ser realizados utilizando duas técnicas principais: retração em massa (RM) ou retração em duas etapas (RDE). Os objetivos principais destes estudos foram avaliar a retração dos incisivos, as mudanças nos tecidos moles e o tempo de retração entre RM e RDE; bem como as taxas de movimentação dos caninos e molares superiores durante a primeira etapa de fechamentos dos espaços utilizando a RDE. A amostra foi composta por modelos, telerradiografias cefalométricas em norma lateral e oblíqua de 45º obtidos antes e durante o tratamento ortodôntico de 48 pacientes biprotrusos cujo os tratamentos foram realizados com extrações de quatro primeiros pré-molares. Todos os pacientes da amostra haviam sido alocados aleatoriamente para o grupo de tratamento utilizando RM (n = 24) ou RDE (n = 24). A retração dos incisivos e as alterações nos tecidos moles foram avaliadas por meio de radiografias cefalométricas em norma lateral do pré-tratamento (T1) e pós-tratamento (T2). Para análise do tempo de retração, o tamanho dos pré-molares foram medidos nos modelos e os dados, referentes ao atendimento clínico, foram coletados dos prontuários nos seguintes tempos: data do início da retração (T1) e data do término do fechamento de espaço (T2). Os movimentos dos caninos e molares superiores foram analisados através das radiografias cefalométricas oblíquas em 45º obtidas antes da retração (T0) e durante o tempo de fechamento dos espaços das extrações: 1º (T1),... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The extraction space closing can be performed using two main retraction techniques: en masse retraction (ER) or two-step retraction (TSR). The main objectives of these studies were to evaluate incisor retraction, soft tissue changes and retraction time between ER and TSR; as well as the movement rates of the maxillary canines and molars during the first step of space closing using the TSR. The sample consisted of models, lateral and oblique cephalometric radiographs at 45º obtained before and during the orthodontic treatment of 48 adult patients with bimaxillary protrusion whose treatments were performed with extractions of four first premolars. All patients had been randomly allocated to either ER (n=24) group or TSR (n=24) group. Both incisor retraction and soft tissue changes were evaluated using pretreatment (T1) and posttreatment (T2) lateral cephalometric radiographs. To analyze the retraction time, the size of the premolars were measured in the models and data were collected from the clinical records in the following times: retraction start date (T1) and space closure completion date (T2). Both maxillary canine and molar movements were analyzed by oblique cephalometric radiographs at 45º taken before the retraction (T0) and during the follow-up of extraction space closing time: on the 1st (T1), 3rd (T3), 5th (T5) and 7th (T7) month. The principal investigator traced, superimposed and digitized all cephalograms from the lateral and oblique cephalometric radiographs at 4... (Complete abstract click electronic access below) / Doutor
109

Efeito da degradação nas propriedades de hastes pultrudadas expostas a ambientes agressivos

Silva, Laís Vasconcelos da January 2017 (has links)
Entre os produtos confeccionados com polímeros reforçados com fibras, as hastes pultrudadas têm sido utilizadas em um número crescente de aplicações devido a características como baixa massa, elevada resistência mecânica, baixo custo de manutenção e alta resistência à corrosão, em particular quando comparadas com hastes confeccionadas em materiais convencionais equivalentes. Porém, os mecanismos de envelhecimento e de degradação dos compósitos poliméricos reforçados com fibras precisam ser mais bem compreendidos, particularmente os mecanismos de dano em condições de serviço, em aplicações de engenharia civil ou em águas profundas. Neste trabalho, foi avaliada a exposição de hastes pultrudadas produzidas a partir de fibras de carbono e vidro e resinas epóxi e éster-vinílica após 3000 horas em diferentes ambientes, como exposição à radiação UV, exposição à água do mar e exposição à água a 60 °C. Os principais aspectos microestruturais, físicos, térmicos, químicos, mecânicos e de vida útil das hastes foram avaliados antes e após as exposições. As hastes com fibras de carbono apresentaram maior resistência residual de forma geral quando comparadas às hastes de fibra de vidro, as quais perderam mais de 50% da sua resistência original após exposições de curta duração (744 h). Quando expostas à radiação UV, as hastes com fibras de carbono apresentaram maior resistência residual à tração, assim como quando submetidas a esforços combinados nos ensaios de SBS. O ambiente mais agressivo entre os estudados definitivamente foi a imersão em água destilada. Os resultados dos ensaios de short-beam apresentaram melhor relação com os efeitos de degradação do que os ensaios de resistência à tração. Através das análises microestruturais (MO e MEV) foi possível identificar alguns tipos de mecanismos de degradação atuantes em cada condição de envelhecimento acelerado. Após analisar uma combinação de fatores envolvidos, a resina epóxi, dentre as resinas estudas, foi a que apresentou melhores propriedades de interface quando utilizada com fibras de carbono. / Among products made with fiber-reinforced polymers, pultruded rods have been used in an increasing number of applications, due to such features as low weight, high strength, low maintenance costs, and high corrosion resistance, particularly when compared with rods manufactured with equivalent conventional materials. However, the ageing and degradation mechanisms of these polymer composite materials still need to be better understood, particularly the damage mechanisms under various service conditions, such as civil engineering or in deep water applications. This thesis presents an experimental study that evaluates the ageing of pultruded rods produced from reinforced carbon and glass fibers and epoxy and vinyl ester resin matrices when exposed to UV radiation, seawater and distilled water at 60 °C for 3000 hours. The degradation assessment in the different environments was made by analyzing and comparing the microstructural, physical, chemical, thermal and mechanical aspects and the lifespan of the pultruded composite rods before and after accelerated ageing. The carbon fiber rods presented a higher residual resistance considering all the aforementioned aspects when compared to the glass fibers rods, which lost more than 50% of their original resistance after short exposure (744 h) to weathering. When exposed to UV radiation, the carbon fiber rods showed higher residual resistance as compared with other types of degrading conditions. Distilled water was undoubtedly the most aggressive ageing factor in respect to all the evaluated properties and characteristics of the tested rods. The short-beam test results showed higher correlation with the degradation effects than the results of the tensile test. By means of microstructural analysis (SEM and OM), it was possible to identify some types of degradation mechanisms for each kind of applied accelerated ageing. After analyzing a combination of factors involved, it was possible to reach the conclusion that the epoxy resin incorporated with carbon fibers displayed the best overall performance among all possible resin/fiber couples
110

Ancoragem em rocha : avaliação da adesão entre nata de cimento e rochas sedimentares em ensaios de laboratório / Anchoring in rock: evaluation of bond strength between cement grout and sedimentary rocks by laboratory tests

Azevedo, Maurício Birkan January 2018 (has links)
A presente dissertação versa sobre a determinação do parâmetro de adesão entre nata de cimento e rocha. Este parâmetro é de fundamental importância no dimensionamento de grampos e tirantes ancorados, sistemas de contenção frequentemente executados que utilizam da técnica de ancoragem. Ensaios de arrancamento in loco são comumente realizados para avaliar essa tensão de aderência, no entanto, muitas vezes, apenas se tornam viáveis financeiramente durante a etapa de execução das obras. A metodologia Composite Cylinder Bond Test (CCBT) permite a determinação da adesão de maneira mais simples e com menor custo, por meio de ensaios de laboratório utilizando corpos de prova mistos de rocha e nata de cimento, sendo, por isto, uma interessante alternativa para a etapa de definição paramétrica de projetos. Neste contexto, foram estudadas três litologias sedimentares do município de Caçapava do Sul/RS – aqui chamadas de conglomerado, arenito muito fino e arenito médio – pertencentes à Formação Varzinha. A caracterização dessas litologias foi realizada por meio de lâminas delgadas e outros ensaios de caracterização de laboratório A classificação textural do conglomerado é de conglomerado arenoso, o arenito muito fino é classificado como arenito lamoso e o arenito médio é classificado como arenito. Do ponto de vista composicional, o arenito muito fino é classificado como arcóseo, enquanto o arenito médio é classificado como arcóseo lítico. Noventa ensaios CCBT, além de ensaios de resistência à compressão simples das rochas e da nata de cimento foram realizados. As tensões de adesão médias obtidas dos ensaios de laboratório foram de 2,52 MPa para o conglomerado, 1,84 MPa para o arenito muito fino e 1,43 MPa para o arenito médio. Foi realizada uma avaliação de intervalos de confiança de valores de tensão de adesão, conforme a distribuição t-student. Concluiu-se que não apenas a resistência das rochas influencia nessa capacidade de adesão, mas também a capacidade de absorção d’água e a porosidade. Maiores valores dessas duas propriedades na rocha favorecem a adesão entre os dois materiais. Os valores encontrados em laboratório são compatíveis com dados de literatura de campo em rochas similares. / This dissertation evaluates the determination of the adhesion parameter between cement grout and rock. This parameter is of great importance on design of two systems frequently executed that use the technique of anchoring: rock anchors and bolts. Pull out field tests are commonly carried out to evaluate this bond strength, however, they are normally only economically feasible during the construction stage. The Composite Cylinder Bond Test (CCBT) methodology allows the adhesion determination in a simpler and cheaper way, by laboratory tests using mixed samples of rock and cement grout. Therefore, the CCBT is an interesting alternative to project definition of adhesion values. In this context, three different sedimentary lithologies from Caçapava do Sul/RS, Southern Brazil, were studied. The lithologies – called here as conglomerate, fine sandstone and medium sandstone – belong to Varzinha Formation. The characterization of these lithologies were made by thin sections and characterization laboratory tests The textural classification of the conglomerate was sandy conglomerate, the fine sandstone was classified as muddy sandstone, and the medium sandstone was classified as sandstone. In the view of their composition, the fine sandstone was classified as arkose, while the medium sandstone was classified as lithic arkose. Ninety CCBT tests, besides unconfined compression tests on rock and cement grout specimens were carried out. The average adhesion values obtained from laboratory tests were 2,52 MPa for the conglomerate, 1,84 MPa for the fine sandstone and 1,43 MPa for the medium sandstone. An evaluation of confidence intervals of adhesion was also carried out, according to t-student distribution. It was concluded that the adhesion strength was influenced not only by the unconfined compressive strength of the rocks, but also by their water absorption and porosity. Larger values of these two properties increased the adhesion between the two materials. The values obtained from laboratory tests are compatible with literature field data in similar rocks.

Page generated in 0.0544 seconds