• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 53
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 53
  • 53
  • 47
  • 43
  • 41
  • 30
  • 25
  • 18
  • 12
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação das distribuições de tensões, por meio da análise de elementos finitos, em uma hemi-maxila, durante a fase de retração anterior por deslizamento, na mecânica ortodôntica / Evaluation of the tensions distributions, using the finite element analysis, in an hemi-maxilla during a sliding anterior retraction , in an orthodontic mechanics

Luiz Vicente de Moura Lopes 15 April 2011 (has links)
O objetivo deste estudo foi analisar, por meio do método dos elementos finitos, como ocorreram as distribuições de tensões nos dentes, osso e aparelho ortodôntico, durante a fase de retração por deslizamento (150g), em um caso com extrações. Simularam-se duas posições do gancho (mesial e distal de canino), duas alturas do gancho (4 e 9mm) e duas alturas posteriores (gancho do tubo do molar e no miniimplante, a 9mm do arco). A amostra consistiu do corte axial da TCFC, de uma mulher de 17 anos de idade, com dentes bem nivelados. Foi desenvolvido um modelo 3D, da geometria da hemi-maxila direita e um modelo numérico, para obter os regimes de tensões e deformações gerados em um sistema de movimentação ortodôntica, por meio do software ANSYS® versão 12.0. Os sólidos dos braquetes e do fio ortodôntico foram incluídos a partir das dimensões fornecidas pelo fabricante. A montagem de todos os componentes foi feita por meio do SolidWorks 2009 SP4.1. A partir do cálculo das respostas do modelo, às cargas a que foi submetido, verificou-se que, os dentes que sofreram maiores concentrações de tensões foram os justapostos aos ganchos, sendo mais intensas as do gancho mesial, particularmente nos incisivos laterais. Embora, a solicitação de tensões no arco tenha sido semelhante em todos os modelos, na posição distal do gancho, houve maior concentração de tensões na extensão imediatamente distal. Os modelos com ganchos de 4mm, diferente aos de 9mm, apresentaram distribuições de tensões mais uniformes, causando menos estresse aos dentes e osso e semelhante ao arco. O modelo com vetor de força direcionado do gancho da mesial do canino ao miniimplante foi o único que mostrou variações, mostrando distribuições de forças mais elevadas na região anterior e posterior ao ser comparado com o vetor de força direcionado ao tubo do primeiro molar. / The aim of this study was to evaluate, by means of finite element analysis, the tensions distrubutions on the teeth, bone and orthodontic appliance, during en-masse retraction sliding mechanics (150g), in an extraction case. It was taken into account two hook positions (mesial and distal to the canine), two hook heights (4mm and 9mm) and two posterior heights ( the first molar tube and the mini-implant, located 9mm from the archwire). The sample of this study consisted of an axial cut realized in a cone beam computed tomography of a 17 years old woman with leveling teeh. It was developed a 3D computed model of a right hemi-maxilla and a computednumerical model capable of getting the systems tensions and deformations generated from an orthodontic moviment system, through a finite element software, ANSYS® 12.0. Observing manufactores specifications, brakets and archwire solids were included in this solid geometric model. The assembly of all componentes were made though the SolidWorks 2009 SP4.1 software. The loads model responses were calculated. The bigger concentration of tension were on the teeth located between the hook. The model with the mesial hook, suffered more intense tensions, mainly on lateral incisors. Although, the tensions request on the archwire were similars in all models, when the hook was located distaly, there were more intense tensions in its immediately distal extension. The 4mm hook models, compared with the 9mm, presented more uniform tensions distribution causing less stress to the teeth and bone and similar to the archwire. The only model that demonstrated variations, was the model with the vector force from the mesial hook and to the mini-implant. This model, demostrated higher tensions distributions on the anterior and posterior region if compared to the first molar tube vector force.
32

Avaliação tomográfica da expansão rápida da maxila assistida por mini-implantes ortodônticos em indivíduos com maturação óssea avançada. /

Oliveira, Cibele Braga January 2019 (has links)
Orientador: Ary dos Santos-Pinto / Resumo: Este estudo clínico retrospectivo pesquisou, em uma amostra de pacientes com maturação óssea avançada, as alterações esqueléticas e dentárias produzidas com a técnica de expansão rápida da maxila assistida por mini-implantes ortodônticos (MARPE) e comparou com as alterações da expansão rápida maxila assistida cirurgicamente (SARPE). Foi pesquisada também a correlação entre o grau de maturação da sutura palatina mediana (SPM), gênero e idade, com os resultados (sucesso ou insucesso) gerados com a técnica MARPE. Por último, em uma amostra maior de 85 pacientes entre 15 e 58 anos de idade, observou-se a prevalência, por gênero e período etário, dos estágios de maturação da sutura palatina mediana. Para o primeiro objetivo, uma amostra de 17 indivíduos tratados com a MARPE foi comparada com outra amostra de 15 pacientes, com faixa etária semelhante, tratados por meio da SARPE. Tomografia Computadorizada de Feixe Cônico antes(T0) e após(T1) a expansão foram avaliadas. Para o segundo objetivo, a mesma amostra da MARPE foi usada para avaliar as alterações esqueléticas observadas na T0 e T1. Imagens do plano axial da SPM foram extraídas da T0 e classificadas em um dos cinco estágios de maturação sutural. Foi avaliada a taxa de sucesso e insucesso quanto aos fatores idade, gênero e maturação sutural. E, para o terceiro objetivo, foram classificadas imagens axiais de SPM de 85 indivíduos entre 15 e 58 anos, para determinar a prevalência da maturação da SPM em relação ao gênero e idade.... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In a sample of patients with advanced bone maturation, this retrospective clinical study investigated the skeletal and dental changes produced by mini-implants assisted rapid palatal expansion (MARPE) compared with the changes in the surgically assisted rapid palatal expansion (SARPE). The correlation between the maturation stage of the midpalatal suture (MPS), sex and age was also investigated, with the results (success or failure) generated with MARPE. At last, in a larger sample of 85 patients between 15 and 58 years of age, the prevalence of maturation stages of the MPS was observed by sex and age period. For the first objective, a sample of 17 individuals, treated with MARPE, was compared with another sample of 15 patients with similar age group, treated with SARPE. CBCT before (T0) and after (T1) expansion were evaluated. For the second objective, the sample MARPE was used to evaluate the skeletal changes observed in T0 and T1. Images of the axial plane of MPS were extracted from T0 and classified into one of the five stages of suture maturation. The success rate and failure by age, sex and suture maturation were evaluated. And for the third objective, MPS axial images of 85 individuals, aged 15 to 58 years, were classified to determine the prevalence of maturation of MPS in relation to sex and age. The results showed that there is a wide variation in relation to the maturation stage of MPS founded in late adolescents and adults. MARPE showed to be a procedure with good... (Complete abstract click electronic access below) / Doutor
33

Avaliação cefalométrica comparativa do tratamento da má oclusão de classe II como Distalizador First Class em ancoragem convencional e esquelética / Comparative cephalometric evaluation of Class II malocclusion treatment with First Class distalizer in conventional and skeletal anchorage

Grec, Roberto Henrique da Costa 27 April 2011 (has links)
O objetivo deste estudo prospectivo foi avaliar as alterações dentoesqueléticas e tegumentares de jovens com má oclusão de Classe II tratados com distalizador First Class em dois tipos diferentes de ancoragem. Foram selecionados 30 pacientes e divididos, aleatoriamente, em dois grupos de 15: G1 (5 masculino e 10 feminino) que recebeu o distalizador com ancoragem convencional no botão de Nance e G2 (10 masculino e 5 feminino) que recebeu o distalizador com ancoragem esquelética apoiado em 2 mini-implantes no palato, com médias de 13,00 e 13,28 anos de idade, respectivamente. As telerradiografias foram obtidas antes e após a distalização dos molares para a realização das análises cefalométricas. A análise estatística foi realizada pelo teste t dependente com a finalidade de verificar as alterações ocorridas dentro de um mesmo grupo e pelo teste t independente para verificar as diferenças entre os grupos. Foi calculado também o erro sistemático e casual. O tempo médio de tratamento foi de 4,51 e 6,28 meses para G1 e G2, respectivamente. Ambos os grupos apresentaram alterações dentárias significantes com distalização (G1=2,39 mm; G2=2,21 mm), angulação distal (G1=10,51º; G2=4,49º) e intrusão (G1=0,53 mm; G2=0,10 mm) dos primeiros molares superiores, sendo apenas sem significância a intrusão em G2. A perda de ancoragem foi semelhante entre os dois grupos, com significante mesialização (G1=2,78 mm; G2=3,11 mm) e angulação mesial (G1=4,95°; G2=4,69°) dos segundos pré-molares, protrusão (G1=1 ,55 mm; G2=1,94 mm) e vestibularização (G1=5,78°; G2=3,13°) significantes dos incisivos superiores e um aumento significante no trespasse horizontal (G1=1,07 mm; G2=0,81 mm). A mecânica de distalização não interferiu nos componentes esqueléticos e tegumentares dos pacientes. Em ambos os grupos, o distalizador First Class promoveu correção da relação molar, porém apresentou efeitos de perda de ancoragem verificada nos pré-molares e incisivos superiores mesmo quando associada à mini-implantes. Não houve diferença significante entre os grupos quanto às alterações dentárias lineares, porém as angulares foram significantemente menores no grupo com ancoragem esquelética. / The aim of this prospective study was to evaluate the dental, skeletal and soft tissue changes in youngsters with Class II malocclusion treated with First Class distalizer in two different types of anchorage. Thirty patients were included and divided, randomly, in two groups of 15. G1 (5 boys and 10 girls) that received distalizers with conventional anchorage (Nance button) and G2 (10 boys and 5 girls) that received distalizers with skeletal anchorage supported in two palatal mini-implants, average age of 13.00 and 13.28 years old, respectively. Lateral cephalometric radiographs were taken before and after molar distalization in order to the cephalometric analysis. Statistical analysis was performed by dependent t test to verify the changes occurred in the same group and by independent t test to verify the difference between the groups. The systematic and casual errors were calculated as well. The mean treatment period was 4.51 and 6.28 months for G1 and G2, respectively. Both groups showed significant dental changes with distalization (G1=2.39 mm; G2=2.21 mm), distal tipping (G1=10.51º; G2=4.49º) and intrusion (G1=0.53 mm; G2=0.10 mm) of maxillary first molars, just intrusion in G2 was not significant. Anchorage loss showed similar in both groups with significant mesialization (G1=2.78 mm; G2=3.11 mm) and mesial tipping (G1=4.95°; G2=4.69°) of maxillary second premolars, significant protrusion (G1=1.55 mm; G2=1.94 mm) and proclination (G1=5.78°; G2=3.13°) of maxillary incisors and significant increase in overjet (G1=1.07 mm; G2=0.81 mm). Distalization mechanic did not interfere in skeletal and soft tissue measurements of patients. In both groups, the First Class distalizer corrected the molar relationship, however it showed anchorage loss effects in maxillary premolars and incisors even when associated to mini-implants. There was no significant difference between the groups on dental linear changes, however the dental angular changes were significantly lower in skeletal anchorage group.
34

Avaliação das alterações dentoesqueléticas de jovens com má oclusão de Classe II tratados com aparelho distalizador First Class Modificado, utilizando modelos digitais e análise cefalométrica / Evaluating of dental and skeletal changes in young Class II malocclusion treated with modified First Class distalizer using digital models and cephalometric analysis

Dias, Fernando Henrique Trigueiro 25 March 2013 (has links)
O objetivo deste estudo foi avaliar as alterações dentoesqueléticas, tegumentares e transversais do arco superior de jovens com má oclusão de Classe II predominantemente dentária, tratados com o distalizador First Class em ancoragem convencional e esquelética. A amostra foi composta por 30 pacientes divididos em três grupos com 10 pacientes cada, nomeados G1 (ancoragem convencional), G2 (ancoragem esquelética) e G3 (modificado com ancoragem squelética). As telerradiografias laterais, para todos os grupos, e os modelos de documentação, para G2 e G3, foram obtidos antes e após a distalização dos molares sendo posteriormente digitalizados para a realização da análise cefalométrica e de modelos digitais. Os dados foram analisados por meio dos testes t pareado, para verificar as alterações produzidas em um mesmo grupo nos tempos inicial e pós distalização, e ANOVA seguido do Teste de Tukey para verificar as diferenças entre os grupos, para dados com distribuição não normal foram utilizados os testes de Wilcoxon e Kruskal-Wallis. O tempo médio de tratamento foi de 4,62 meses para o G1; 5,41 meses para o G2 e 3,91 meses para o G3, não havendo diferença entre eles. A análise dos primeiros molares demonstrou que todos os grupos presentaram alterações dentárias significantes na angulação (G1= -8,42o; G2= -5,98o; G3= - 6,12o), apenas os grupos G1 e G3 (G1= -1,63 mm; G2= -1,31 mm; G3= - 1,91 mm) apresentaram alterações significantes na distalização e não foram detectadas alterações verticais (G1= -1,63 mm; G2= -1,31 mm; G3= -1,91 mm). A perda de ancoragem anterior foi significantemente menor para os valores angulares no G3 demonstrando uma suave vestibularização dos incisivos centrais (G1= 4,76o; G2= 4,49o; G3= 0,64o) e menor angulação mesial dos segundos pré-molares (G1= 6,69o; G2= 10,29o; G3= 3,55o), não havendo diferenças entre os grupos para os componentes lineares horizontais (G1= 1,77 mm; G2= 1,72 mm; G3= 1,05 mm) e verticais (G1= -0,17 mm; G2= -0,02 mm; G3= 0,31mm) dos incisivos e lineares horizontais (G1= 2,88 mm; G2= 3,19 mm; G3= 2,43 mm) e verticais (G1= 0,37 mm; G2= 0,63 mm; G3= 0,95 mm) dos segundos pré-molares. A distalização promoveu ainda um aumento mais acentuado da AFAI para o G3 (G1= 0,49 mm; G2= 1,20 mm; G3= 1,71 mm) e uma menor alteração do ANL também para o G3 (G1= -4,71o; G2= -2,82º; G3= 0,42o). A análise dos modelos digitais demonstrou diferença significante apenas para a distância entre segundos pré-molares (G2= -2,14 mm; G3= -1,10 mm). Todos os aparelhos estudados são eficazes para realizar a correção da relação molar promovendo uma perda de ancoragem anterior, sendo este efeito indesejado menor para o distalizador First Class modificado associado à ancoragem esquelética. / The aim of this study was to evaluate the dentoskeletal, soft tissue and maxillary transverse dimensions changes in youngsters with dental Class II malocclusion treated with First Class distalizer in skeletal and conventional anchorage. Thirty patients were included and divided in three groups of 10 patients each, named G1 (conventional anchorage), G2 (skeletal anchorage) and G3 (modified First Class with skeletal anchorage). Lateral radiographs, for all groups, and dental casts, for G2 and G3, were obtained before and after molar distalization and subsequently scanned to perform cephalometric and digital models analysis. Data were analyzed using paired t tests to verify the same group changes at initial and after distalization time, and ANOVA followed by Tukey test to detect differences between groups, for data with non-normal distribution were used Wilcoxon and Kruskal-Wallis tests. No difference was found in treatment time (G1= 4.62 months, G2= 5.41 months, G3= 3.91 months). First molars analysis showed that all groups had significant dental angulation changes (G1= -8.42o, G2= -5.98o, G3= -6.12°), G1 an d G3 showed significant distalization changes (G1= -1.63 mm, G2= -1.31 mm; G3= - 1.91 mm) and no vertical changes were detected (G1= -1.63 mm, G2= -1.31 mm, G3= -1.91 mm). Anchorage loss was significantly smaller to the G3 angular measurements, demonstrating a little incisors vestibularization (G1= 4.76o, G2= 4.49o, G3= 0.64o) and little second premolars mesial angulation (G1= 6.69o, G2= 10.29o, G3= 3.55o), with no horizontal linear changes (G1= 1.77 mm, G2= 1.72 mm, G3= 1.05 mm) and no vertical linear differences between groups (G1= -0.17 mm , G2= -0.02 mm, G3= 0.31 mm) of incisors and horizontal linear (G1= 2.88 mm, G2= 3.19 mm, G3= 2,43 mm) and vertical (G1= 0.37 mm, G2= 0.63 mm, G3= 0.95 mm) of the second premolars. Distalization increased the LAFH to G3 (G1= 0.49 mm, G2= 1.20 mm, G3= 1.71 mm) and also promoted changes in G3 NLA (G1= -4.71o, G2= -2.82o, G3= 0.42°). Digital models analysis showed a significant difference only for the second premolars transverse dimension (G2 = -2.14 mm; G3= -1.10 mm). All devices studied were effective to perform the molar relationship correction, resulting an anchorage loss, this unwanted effect was lesser with modified First Class distalizer with skeletal anchorage.
35

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Roberto Bombonatti 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
36

Avaliação das alterações dentoesqueléticas de jovens com má oclusão de Classe II tratados com aparelho distalizador First Class Modificado, utilizando modelos digitais e análise cefalométrica / Evaluating of dental and skeletal changes in young Class II malocclusion treated with modified First Class distalizer using digital models and cephalometric analysis

Fernando Henrique Trigueiro Dias 25 March 2013 (has links)
O objetivo deste estudo foi avaliar as alterações dentoesqueléticas, tegumentares e transversais do arco superior de jovens com má oclusão de Classe II predominantemente dentária, tratados com o distalizador First Class em ancoragem convencional e esquelética. A amostra foi composta por 30 pacientes divididos em três grupos com 10 pacientes cada, nomeados G1 (ancoragem convencional), G2 (ancoragem esquelética) e G3 (modificado com ancoragem squelética). As telerradiografias laterais, para todos os grupos, e os modelos de documentação, para G2 e G3, foram obtidos antes e após a distalização dos molares sendo posteriormente digitalizados para a realização da análise cefalométrica e de modelos digitais. Os dados foram analisados por meio dos testes t pareado, para verificar as alterações produzidas em um mesmo grupo nos tempos inicial e pós distalização, e ANOVA seguido do Teste de Tukey para verificar as diferenças entre os grupos, para dados com distribuição não normal foram utilizados os testes de Wilcoxon e Kruskal-Wallis. O tempo médio de tratamento foi de 4,62 meses para o G1; 5,41 meses para o G2 e 3,91 meses para o G3, não havendo diferença entre eles. A análise dos primeiros molares demonstrou que todos os grupos presentaram alterações dentárias significantes na angulação (G1= -8,42o; G2= -5,98o; G3= - 6,12o), apenas os grupos G1 e G3 (G1= -1,63 mm; G2= -1,31 mm; G3= - 1,91 mm) apresentaram alterações significantes na distalização e não foram detectadas alterações verticais (G1= -1,63 mm; G2= -1,31 mm; G3= -1,91 mm). A perda de ancoragem anterior foi significantemente menor para os valores angulares no G3 demonstrando uma suave vestibularização dos incisivos centrais (G1= 4,76o; G2= 4,49o; G3= 0,64o) e menor angulação mesial dos segundos pré-molares (G1= 6,69o; G2= 10,29o; G3= 3,55o), não havendo diferenças entre os grupos para os componentes lineares horizontais (G1= 1,77 mm; G2= 1,72 mm; G3= 1,05 mm) e verticais (G1= -0,17 mm; G2= -0,02 mm; G3= 0,31mm) dos incisivos e lineares horizontais (G1= 2,88 mm; G2= 3,19 mm; G3= 2,43 mm) e verticais (G1= 0,37 mm; G2= 0,63 mm; G3= 0,95 mm) dos segundos pré-molares. A distalização promoveu ainda um aumento mais acentuado da AFAI para o G3 (G1= 0,49 mm; G2= 1,20 mm; G3= 1,71 mm) e uma menor alteração do ANL também para o G3 (G1= -4,71o; G2= -2,82º; G3= 0,42o). A análise dos modelos digitais demonstrou diferença significante apenas para a distância entre segundos pré-molares (G2= -2,14 mm; G3= -1,10 mm). Todos os aparelhos estudados são eficazes para realizar a correção da relação molar promovendo uma perda de ancoragem anterior, sendo este efeito indesejado menor para o distalizador First Class modificado associado à ancoragem esquelética. / The aim of this study was to evaluate the dentoskeletal, soft tissue and maxillary transverse dimensions changes in youngsters with dental Class II malocclusion treated with First Class distalizer in skeletal and conventional anchorage. Thirty patients were included and divided in three groups of 10 patients each, named G1 (conventional anchorage), G2 (skeletal anchorage) and G3 (modified First Class with skeletal anchorage). Lateral radiographs, for all groups, and dental casts, for G2 and G3, were obtained before and after molar distalization and subsequently scanned to perform cephalometric and digital models analysis. Data were analyzed using paired t tests to verify the same group changes at initial and after distalization time, and ANOVA followed by Tukey test to detect differences between groups, for data with non-normal distribution were used Wilcoxon and Kruskal-Wallis tests. No difference was found in treatment time (G1= 4.62 months, G2= 5.41 months, G3= 3.91 months). First molars analysis showed that all groups had significant dental angulation changes (G1= -8.42o, G2= -5.98o, G3= -6.12°), G1 an d G3 showed significant distalization changes (G1= -1.63 mm, G2= -1.31 mm; G3= - 1.91 mm) and no vertical changes were detected (G1= -1.63 mm, G2= -1.31 mm, G3= -1.91 mm). Anchorage loss was significantly smaller to the G3 angular measurements, demonstrating a little incisors vestibularization (G1= 4.76o, G2= 4.49o, G3= 0.64o) and little second premolars mesial angulation (G1= 6.69o, G2= 10.29o, G3= 3.55o), with no horizontal linear changes (G1= 1.77 mm, G2= 1.72 mm, G3= 1.05 mm) and no vertical linear differences between groups (G1= -0.17 mm , G2= -0.02 mm, G3= 0.31 mm) of incisors and horizontal linear (G1= 2.88 mm, G2= 3.19 mm, G3= 2,43 mm) and vertical (G1= 0.37 mm, G2= 0.63 mm, G3= 0.95 mm) of the second premolars. Distalization increased the LAFH to G3 (G1= 0.49 mm, G2= 1.20 mm, G3= 1.71 mm) and also promoted changes in G3 NLA (G1= -4.71o, G2= -2.82o, G3= 0.42°). Digital models analysis showed a significant difference only for the second premolars transverse dimension (G2 = -2.14 mm; G3= -1.10 mm). All devices studied were effective to perform the molar relationship correction, resulting an anchorage loss, this unwanted effect was lesser with modified First Class distalizer with skeletal anchorage.
37

Avaliação cefalométrica comparativa do tratamento da má oclusão de Classe II com o distalizador first class em ancoragem convencional e esquelética e aparelho extrabucal cervical seguidos de aparelho fixo / Comparative cephalometric evaluation of Class II malocclusion treatment with First Class distalizer in conventional and skeletal anchorage and cervical headgear followed by fixed orthodontic appliance

Grec, Roberto Henrique da Costa 06 April 2015 (has links)
O objetivo deste estudo longitudinal foi comparar as alterações dentoesqueléticas e tegumentares de jovens com má oclusão de Classe II não tratados e tratados com distalizador First Class em ancoragem convencional ou esquelética, ou com o aparelho extrabucal cervical (AEB), seguidos do aparelho fixo. A amostra foi composta por 44 pacientes com má oclusão de classe II e divididos em quatro grupos de 11 cada: pacientes tratados com distalizador First Class com ancoragem convencional no botão de Nance (G1), tratados com distalizador First Class com ancoragem esquelética apoiado em 2 mini-implantes no palato (G2), tratados com o aparelho extrabucal (AEB) (G3) e o grupo controle, com pacientes não tratados (G0). Foram obtidas as telerradiografias ao início (Ti) e final (Tf) do tratamento para a realização das análises cefalométricas e avaliação das alterações dentárias, esqueléticas e tegumentares e compará-los com o grupo controle (G0). A análise estatística foi realizada pelo teste t pareado com a finalidade de verificar as alterações ocorridas dentro de um mesmo grupo e pelo teste ANOVA a um critério e teste de Tukey para verificar as diferenças entre os grupos. Observou-se restrição e redirecionamento do crescimento maxilar ao final do tratamento no G1 e G3. Os efeitos esqueléticos na mandíbula só foram significantes no G0. As medidas da relação maxilomandibular diminuíram significantemente no G1 e G3 com significante diminuição das medidas que avaliaram o perfil tegumentar. Quanto ao componente vertical todas as medidas aumentaram no G3. Os primeiros molares superiores angularam distalmente no G2 e os inferiores mesialmente no G3. Os quatro grupos apresentaram extrusão dos dentes superiores e inferiores. Os três grupos experimentais apresentaram diminuição significante nas relações dentárias (relação molar, trespasse horizontal e vertical). Conclui-se que os grupos experimentais corrigiram a má colusão de Classe II de maneira satisfatória, sendo que o uso do AEB mostrou efeitos esqueléticos e dentários na correção e os grupos com distalizadores somente efeitos dentários. O tempo de tratamento no grupo com AEB foi significantemente menor. / The aim of this prospective study was to compare the dental, skeletal and soft tissue changes in youngsters with Class II malocclusion untreated and treated with First Class distalizer in conventional or skeletal achorage or with cervical headgear followed by fixed orthodontic appliances. The sample consisted of 44 patients with Class II malocclusion and divided into four groups of 11: patients treated with First Class distalizer with conventional anchorage (Nance button)(G1), treated with First Class distalizer with skeletal anchorage supported in two palatal mini-implants (G2), treated with cervical headgear (G3) and follow-up group with untreated patients (G0). Lateral cephalometrics radiographs were taken before treatment and after treatment in order to cephalometric analysis and evaluate the dental, skeletal and soft tissue changes and to compare with follow-up group (G0). Statistical analysis was performed by dependent t test to verify the changes occurred in the same group and by one-way ANOVA and Tukey test to verify the changes occurred between the groups. It was observed restriction and redirection of maxillary growth after treatment in G1 and G3. Mandibular skeletal effects were significant in G0. The values of skeletal maxilomandibular relationship decreased significantly in G1 and G3 with significant decrease of measurements that evaluated soft facial profile. All measurements of vertical component increased in G3. Maxillary first molars were distal tipping in G2 and lower first molars were mesial tipping in G3. The four groups showed extrusion in the upper and lower teeth. The three experimental groups showed significant decreased in the molar relationship, overjet and overbite. It concluded that experimental groups corrected the Class II malocclusion efficiently, cervical headgear showed skeletal and dental effects and the groups with distalizers showed only dental effects. The mean treatment period was significant lower with cervical headgear.
38

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Bombonatti, Roberto 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
39

Estudo comparativo de diferentes mini-implantes utilizados para mesialização de segundo molar inferior : análise por elementos finitos 3d /

Lisboa, Juliana da Costa. January 2018 (has links)
Orientador: Fellippo Ramos Verri / Coorientador: João Maurício Ferraz da Silva / Banca: Fellippo Ramos Verri / Banca: José Benedito Oliveira Amorim / Banca: Virgílio Vilas Boas Fernandes Junior / Resumo: A perda do primeiro molar é uma situação comum na rotina do consultório e com isso surgem alternativas de tratamento para reabilitação, sendo uma delas, o fechamento de espaço através da mesialização do segundo molar. O uso de mini- implante proporciona ancoragem máxima, costuma ser bem tolerado pelo paciente e se destaca pela facilidade de instalação e remoção, apresentando dessa maneira desempenho clínico bastante favorável. O objetivo desse estudo foi analisar a distribuição de tensões em modelo que simula a mesialização de molar inferior utilizando diferentes tipos de mini-implantes. Embasado no método dos elementos finitos foi obtido modelo ósseo de mandíbula por recomposição de uma tomografia computadorizada realizada pelo software Invesalius (CTI, São Paulo, Brasil). O desenho do segundo molar foi obtido por técnica de recomposição tomográfica. Elementos de ancoragem auto-perfurantes da marca Neodent e também auto-rosqueantes da marca Titanium Fix foram desenhados e modelados por ferramenta de revolução do perfil desenhado no software Rhinoceros 3D, inseridos ao bloco ósseo e então submetidos a cargas de 200 cN. Os resultados foram calculados e analisados pelo programa Ansys 17.0 para verificação por meio da análise de mapas de deslocamento e tensões máximas principais, principalmente do osso cortical e indicaram que, dentro do modelo experimental, o ligamento periodontal apresentou valores baixos de tensão máxima principal, porém dentro dos valores fisiológicos para p... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The loss of the first molar is a common situation in the routine of the dentist and with this treatment alternatives for rehabilitation arises, one of them being the closure of space through the mesialization of the second molar. The use of mini-implants provides maximum anchorage, is well tolerated by the patient and stands out for ease installation and removal, thus presenting a very favorable clinical performance. The objective of this study was to analyze the stress distribution in a model that simulates the inferior molar mesialization using different types of mini- implants. Based on the finite element method, a mandible bone model was obtained by recomposing a computerized tomography performed by invesalius software (CTI, São Paulo, Brazil). The second molar design was obtained by a technique similar to the tomographic recomposition. Neodent self-piercing anchoring elements and also Titanium Fix self-piercing anchors were designed and modeled by a revolution tool in the Rhinoceros 3D software, inserted into the bone block and then subjected to loads of up to 200 cN. The results were calculated and analyzed by the Ansys 17.0 program for verification by means of the analysis of displacement maps and main maximum stresses, mainly of the cortical bone and indicated that, within the experimental model, the periodontal ligament presented low values of main maximum tension, however within the physiological values to provide the movement, with visualization of areas of compres... (Complete abstract click electronic access below) / Mestre
40

Avaliação das alterações nos tecidos moles, do tempo de retração e da movimentação de incisivos, caninos e molares em casos de extrações de pré-molares /

Schneider, Patricia Pigato. January 2019 (has links)
Orientador: Luis Gonzaga Gandini Junior / Resumo: Os fechamentos dos espaços das extrações pode ser realizados utilizando duas técnicas principais: retração em massa (RM) ou retração em duas etapas (RDE). Os objetivos principais destes estudos foram avaliar a retração dos incisivos, as mudanças nos tecidos moles e o tempo de retração entre RM e RDE; bem como as taxas de movimentação dos caninos e molares superiores durante a primeira etapa de fechamentos dos espaços utilizando a RDE. A amostra foi composta por modelos, telerradiografias cefalométricas em norma lateral e oblíqua de 45º obtidos antes e durante o tratamento ortodôntico de 48 pacientes biprotrusos cujo os tratamentos foram realizados com extrações de quatro primeiros pré-molares. Todos os pacientes da amostra haviam sido alocados aleatoriamente para o grupo de tratamento utilizando RM (n = 24) ou RDE (n = 24). A retração dos incisivos e as alterações nos tecidos moles foram avaliadas por meio de radiografias cefalométricas em norma lateral do pré-tratamento (T1) e pós-tratamento (T2). Para análise do tempo de retração, o tamanho dos pré-molares foram medidos nos modelos e os dados, referentes ao atendimento clínico, foram coletados dos prontuários nos seguintes tempos: data do início da retração (T1) e data do término do fechamento de espaço (T2). Os movimentos dos caninos e molares superiores foram analisados através das radiografias cefalométricas oblíquas em 45º obtidas antes da retração (T0) e durante o tempo de fechamento dos espaços das extrações: 1º (T1),... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The extraction space closing can be performed using two main retraction techniques: en masse retraction (ER) or two-step retraction (TSR). The main objectives of these studies were to evaluate incisor retraction, soft tissue changes and retraction time between ER and TSR; as well as the movement rates of the maxillary canines and molars during the first step of space closing using the TSR. The sample consisted of models, lateral and oblique cephalometric radiographs at 45º obtained before and during the orthodontic treatment of 48 adult patients with bimaxillary protrusion whose treatments were performed with extractions of four first premolars. All patients had been randomly allocated to either ER (n=24) group or TSR (n=24) group. Both incisor retraction and soft tissue changes were evaluated using pretreatment (T1) and posttreatment (T2) lateral cephalometric radiographs. To analyze the retraction time, the size of the premolars were measured in the models and data were collected from the clinical records in the following times: retraction start date (T1) and space closure completion date (T2). Both maxillary canine and molar movements were analyzed by oblique cephalometric radiographs at 45º taken before the retraction (T0) and during the follow-up of extraction space closing time: on the 1st (T1), 3rd (T3), 5th (T5) and 7th (T7) month. The principal investigator traced, superimposed and digitized all cephalograms from the lateral and oblique cephalometric radiographs at 4... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0414 seconds