• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise molecular de amostras negativas para o antígeno específico da próstata (PSA) coletadas de vítimas de crimes sexuais / Molecular analysis of negative samples to prostate-specific antigen (PSA) collected from sex crimes victims

Ruiz, Karine Pequeno Nakao 20 April 2017 (has links)
Submitted by Vasti Diniz (vastijpa@hotmail.com) on 2017-09-08T14:06:42Z No. of bitstreams: 1 arquivototal.pdf: 2742380 bytes, checksum: cf8f43acdec2329a5d6d78a8a373b6b7 (MD5) / Made available in DSpace on 2017-09-08T14:06:42Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2742380 bytes, checksum: cf8f43acdec2329a5d6d78a8a373b6b7 (MD5) Previous issue date: 2017-04-20 / The finding of sperm through the screening tests on samples collected from rape victims confirms the occurrence of the sexual act, but its absence usually closes biological research in the crime in question, leaving a gap about the authorship of the crime, as well as about the criminal typification. The present work aimed to analyze the need of implementation in forensic routine of Genetics Laboratories of molecular analysis of negative samples to the prostate-specific antigen (PSA) collected from sex crimes victims. Vaginal swabs were selected and proceedings collected from 200 women who have been victims of those crimes in Paraíba from January 2015 to January 2016. Such materials had been sorted and presented negative result for PSA. Proceeded to the sample quantification by Real-time PCR using the Plexor® HY kit and there was a far greater concentration of autosomal DNA in relation to the male DNA. With the use of thermal cyclers GeneAmp® PCR System 9700, 200 DNA samples extracted from the sperm fraction (SF) were amplified for Y-STR with the use of PowerPlex® Y23 Systems and AmpFlSTR® Yfiler PCR Amplification kits. Such products have been subjected to capillary electrophoresis in genetic sequencer ABI PRISM™ 3500 Genetic Analyzer and the results analyzed by GeneMapper® ID software v 3.2. The fractions analyzed, only two full profiles amplification (1%), 24 (12%) partials, while the 174 remaining samples (87%) did not present any amplification. Screening with PSA testing negative served, statistically, how to determine guiding absence of sperm in swabs of vaginal origin and anally for victims of sex crimes. However, in this study were analyzed samples from rape victims. Due to the large social call caused by this type of crime, any nonzero statistic must be acceptable to a presumptive test. The results obtained have awakened to the need to study a new way of sorting this material, as well as the repetition of some analytical steps in order to get a genetic profile informative for illicit criminal resolution. / A constatação de espermatozoides, através dos testes de triagem, em amostras coletadas de vítimas de estupro confirma a ocorrência do ato sexual, todavia a sua ausência geralmente encerra a investigação biológica no crime em questão, ficando uma lacuna quanto à autoria do delito, bem como quanto à tipificação penal. O presente trabalho objetivou analisar a necessidade de implantação na rotina dos laboratórios de genética forense da análise molecular de amostras negativas para o antígeno específico da próstata (PSA) coletadas de vítimas de crimes sexuais. Foram selecionadas swabs vaginais e anais coletados de 200 mulheres que foram vítimas desses crimes na Paraíba entre os meses de janeiro de 2015 e janeiro de 2016. Tais materiais haviam sido triados e apresentaram resultado negativo para PSA. Procedeu-se à quantificação amostral por PCR em tempo real, com uso do kit Plexor® HY e observou-se uma concentração bem maior de DNA autossômico com relação ao DNA masculino. Com uso de termocicladores GeneAmp® PCR System 9700, 200 amostras de DNA extraído das frações espermáticas (FE) foram amplificadas para Y-STR com o emprego dos sistemas PowerPlex® Y23 System e AmpFlSTR® Yfiler® PCR Amplification. Tais produtos foram submetidos à eletroforese capilar em seqüenciador genético ABI PRISM 3500™ Genetic Analyzer e os resultados analisados pelo software GeneMapper® ID v3.2. Das frações analisadas, constatou-se amplificação de apenas dois perfis completos (1%), 24 parciais (12%), enquanto as 174 amostras restantes (87%) não apresentaram amplificação alguma. O teste de triagem com PSA negativo serviu, estatisticamente, como norteador para se determinar a ausência de esperma em swabs de origem vaginal e anal das vítimas de crimes sexuais. Contudo, no presente trabalho foram analisadas amostras provenientes de vítimas de estupro. Devido ao grande apelo social provocado por esse tipo de crime, nenhuma estatística diferente de zero deve ser aceitável para um teste presuntivo. Os resultados obtidos despertaram para a necessidade de estudar uma nova forma de triagem desse material, bem como pela repetição de alguns passos analíticos no intuito de se obter um perfil genético informativo para resolução do ilícito penal.
2

Filmes nanoestruturados para detecção do antígeno prostático específico / Nanoestructured film from prostate specific antigen detection

Graça, Juliana Santos 08 March 2016 (has links)
Submitted by Milena Rubi (milenarubi@ufscar.br) on 2016-11-01T17:21:21Z No. of bitstreams: 1 GRAÇA_Juliana_2016.pdf: 30861843 bytes, checksum: d0a3ae0ba919e89cac0abf5511fb0fd6 (MD5) / Approved for entry into archive by Milena Rubi (milenarubi@ufscar.br) on 2016-11-01T17:21:34Z (GMT) No. of bitstreams: 1 GRAÇA_Juliana_2016.pdf: 30861843 bytes, checksum: d0a3ae0ba919e89cac0abf5511fb0fd6 (MD5) / Approved for entry into archive by Milena Rubi (milenarubi@ufscar.br) on 2016-11-01T17:21:49Z (GMT) No. of bitstreams: 1 GRAÇA_Juliana_2016.pdf: 30861843 bytes, checksum: d0a3ae0ba919e89cac0abf5511fb0fd6 (MD5) / Made available in DSpace on 2016-11-01T17:22:03Z (GMT). No. of bitstreams: 1 GRAÇA_Juliana_2016.pdf: 30861843 bytes, checksum: d0a3ae0ba919e89cac0abf5511fb0fd6 (MD5) Previous issue date: 2016-03-08 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / In the present work, Layer-by-Layer films of Anti-PSA antibody in the absence and presence of DPPG liposomes were produced in order to study the detection of prostate specific antigen (PSA) by different characterization techniques. The free Anti-PSA antibody in solution and incorporated into liposome was characterized by UV-vis spectroscopy and Circular Dichroism (CD). In the first characterization, it was verified the main absorption bands of the antibody and a possible aggregation in the absence of the liposome. CD measurements indicated disordered structures of free antibody. However, its secondary structure (ß-Sheet) was maintained in the presence of liposomes. The film Layer- by-Layer of free Anti-PSA antibody and incorporated into DPPG liposomes was done alternating the antibody with different polycations, PAH (poly (allylamine hydrochloride)) and PEI (poly (ethyleneimine)). The films fabricate on quartz and gold sensors were characterized by UV-vis and SPR spectroscopy. These results proved the deposition of the materials on different substrates and the PEI was the best polyelectrolyte for immobilization of the antibody. Through the SPR measures it was simulated thickness and refractive index of the film bilayers. The PEI, PVS and Anti-PSA casting film and PEI/PVS and PEI/Anti-PSA LbL films were characterized by FTIR, it was observed through the bands of the spectra the interaction between the polyelectrolyte and found the deposition of antibody in the film. Acting as PSA detection unit, the (PEI/PVS)1/(PEI/Anti-PSA+DPPG)5 and (PEI/PVS)1/(PEI/Nati-PSA)5 films were characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and SPR and both systems were able to detect PSA at concentrations below 4 ng.mL-1 that is the normal concentration for a healthy individual. / No presente trabalho foram produzidos filmes nanoestruturados camada por camada (LbL) de anticorpo Anti-PSA na ausência e na presença de lipossomos de DPPG, a fim de estudar a detecção do antígeno prostático específico (PSA) por diferentes técnicas de caracterização. A solução de anticorpo Anti-PSA, livre e incorporado em lipossomo, foi caracterizada por espectroscopia UV-vis e Dicroísmo Circular (CD). Sendo que no primeiro caso, foram verificadas as principais bandas de absorção do anticorpo e uma possível agregação na ausência do lipossomo. As medidas de CD indicaram estruturas desordenadas do anticorpo livre e na presença do lipossomo o anticorpo manteve a sua estrutura secundária (Folha-ß). Os filmes LbL de anticorpo Anti-PSA e Anti-PSA+DPPG, alternados com diferentes policátions, PAH (poli(alilamina hidroclorada)) ou PEI (poli(etilenoimina)) foram fabricados sobre quartzo e o sensor de ouro modificado com 11-MUA e caracterizados por espectroscopia UVvis e Ressonância Plasmônica de Superfície (SPR), no qual foi constatado a deposição dos materiais nos diferentes substratos e definido o PEI como melhor polieletrólito para imobilização do anticorpo. Através das medidas de SPR também foi simulado a espessura e o índice de refração das bicamadas de filmes. Os filmes casting de PEI, PVS e Anti-PSA e os filmes LbL destes materiais foram caracterizados por Espectroscopia de Absorção no Infravermelho com Transformada de Fourier (FTIR), através das bandas dos espectros no modo de transmissão e reflexão verificou-se a interação entre os polieletrólitos e constatou a deposição do anticorpo no filme. Atuando como unidade de detecção do PSA os filmes de (PEI/PVS)1/(PEI/Anti-PSA+DPPG)5 e de (PEI/PVS)1/(PEI/Nati-PSA)5 foram caracterizados por voltametria cíclica (VC), espectroscopia de impedância eletroquímica (EIE) e por SPR, e, ambos sistemas foram capazes de detectar o PSA em concentrações inferiores a 4 ng.mL-1 que é a concentração normal para um indivíduo saudável. / 2013/23288-0

Page generated in 0.0774 seconds