• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 1
  • Tagged with
  • 25
  • 25
  • 20
  • 18
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Detecção condutométrica sem contato (oscilométrica) para eletroforese capilar de zona e cromatografia micelar eletrocinética / Contactless conductivity detection for capillary zone electrophoresis and micellar electrokinetic chromatography

Silva, José Alberto Fracassi da 19 March 2001 (has links)
Este trabalho descreve a construção e avaliação de um detector condutométrico sem contato (oscilométrico) para sua aplicação em eletroforese capilar de zona e cromatografia micelar eletrocinética (MEKC). A construção do detector contou com a avaliação de diversos materiais e métodos para a confecção dos eletrodos, tão bem como o aperfeiçoamento do seu circuito eletrônico. O seu comportamento e desempenho foram verificados através do estudo dos diversos parâmetros que influenciam sua resposta, como freqüência e amplitude do sinal aplicado, temperatura e condutividade do meio. Além disso, a simulação do circuito equivalente da cela de detecção auxiliou no entendimento das propriedades do detector frente a alterações na condutividade do meio, na freqüência de operação e nas dimensões da cela. A otimização dos parâmetros operacionais foi racionalizada pela formulação de equações analíticas que descrevem o fator de resposta do detector a partir de parâmetros obtidos experimentalmente. Para o desenvolvimento do sistema de detecção, dois equipamentos completos de eletroforese capilar foram construídos. Sistemas de injeção de amostra por pressão, por gravidade, e eletrocinética foram desenvolvidos. Um dos equipamentos permite que a injeção da amostra seja feita do lado aterrado da fonte de alta tensão. Conseqüentemente, o detector é posicionado próximo do ponto de aplicação da alta tensão. Este é, de que se tem notícia, o primeiro sistema de detecção eletroquímico para eletroforese capilar com essa característica. A termostatização dos capilares foi efetuada por convecção forçada de ar. De maneira a aumentar o grau de automação e facilitar o seu manuseio, os dois equipamentos foram interfaceados a microcomputador. Os equipamentos de eletroforese com detecção oscilométrica construídos permitiram a análise de diversas substâncias em matrizes variadas, como por exemplo íons orgânicos e inorgânicos em água de chuva e material particulado, ácidos graxos de cadeia linear em gordura de coco, formaldeído na fase gasosa da atmosfera, e, pela primeira vez, espécies neutras, como álcoois alifáticos, separadas por MEKC. / This work describes the construction and evaluation of a contactless conductometric (or oscillometric) detector, for its application in capillary zone electrophoresis and micellar electrokinetic chromatography (MEKC). The materials and methods used for the construction of the electrodes, as well as the improvements on the electronic circuit, were evaluated. The behavior and performance of the detector were studied by changing the parameters that affect its response, e. g., the frequency and amplitude of the input signal, temperature and solution conductivity. The simulation of the cell equivalent electric circuit helped to understand the detector properties related to the variations in the solution conductivity, frequency, and cell dimensions. The optimization of the parameters was conducted by the formulation of analytical equations that describe the response factor using experimental data. For the detection development, two complete capillary electrophoresis equipments were constructed. Pressure, gravity, and electrokinetic sample injection systems were developed. One of the equipments allows the sample injection on the grounded side of the capillary. Consequently, the detector is placed near the high voltage application point. This is the first electrochemical detector described for capillary electrophoresis with this characteristic. The capillary thermostating was made by passing a forced air stream. Both equipments were interfaced to microcomputers. The capillary electrophoresis equipments with oscillometric detection were applied to the analysis of many types of compounds in different matrices, such as organic and inorganic ions in rainwater and particulate material, fatty acids in cocoa oil, formaldehyde in the atmosphere and, for the first time, neutral species, like aliphatic alcohols, separated by MEKC.
2

"Fabricação e avaliação de microdispositivos para eletroforese com detecção eletroquímica" / "Fabrication and Evaluation of Electrophoresis Microdevices coupled with Electrochemical Detection"

Coltro, Wendell Karlos Tomazelli 03 September 2004 (has links)
Este trabalho descreve o desenvolvimento de microchips para eletroforese a partir dos processos de impressão direta e fotolitográfico. A estrutura dos microcanais fabricados pelo processo de impressão direta são definidos por filmes de poliéster (base e tampa) e por uma camada de toner (paredes). A caracterização da superfície e da composição do toner foram necessárias para um melhor entendimento da composição química da estrutura dos microcanais e para este propósito foram utilizadas diferentes técnicas como análise elementar de CHN-O, AFM, EDX e MEV. Além da química do toner as dimensões limites para os canais, como largura e altura, também foram estudadas. A aplicação de um efeito de cinza nos microcanais foi avaliado de modo a desenvolver um dispositivo de pré-concentração usando as partículas de toner como obstáculos para o fluxo. Os microdispositivos fabricados em poliéster-toner foram integrados com detecção amperométrica no final do canal de separação usando eletrodos produzidos a partir da combinação das tecnologias da produção de máscaras de toner e CDs, como fonte de ouro. O desempenho destes microchips foi avaliado com detecção amperométrica da separação eletroforética de iodeto e ascorbato. Os limites de detecção obtidos foram de 500 nmol L-1 (135 amol) e 1,2 mmol L-1 (486 amol) para o iodeto e ascorbato, respectivamente. Além do processo de impressão direta, o processo fotolitográfico também foi utilizado para a mesma finalidade. Neste processo foi utilizado o fotorresiste negativo SU-8 e microdispositivos com área de 1 cm2 foram fabricados usando diferentes substratos como vidro, silício e alumina. A alumina apresentou muitas irregularidades para os microdispositivos fabricados. Problemas com a absorção e dispersão da radiação ultravioleta foram observados. No entanto, a alumina foi um excelente material para as etapas de produção de dois moldes metálicos para a rápida produção de dispositivos poliméricos. Um molde com uma geometria complexa foi obtido para estudar um novo sistema de injeção e um segundo molde foi preparado para avaliar o uso de uma borracha de silicone como material moldante. Além disso, este trabalho também apresenta o desenvolvimento de um dispositivo microfabricado com eletrodos completamente integrados para separação e detecção eletroquímica. Eletrodos de ouro ou de titânio/platina foram obtidos através da técnica lift-off. As máscaras para a fabricação de moldes metálicos e dos dispositivos integrados foram preparadas em fotolito de alta resolução. / This work describes the development of electrophoresis microchip fabricated by direct-printing and photolithographic processes. The channel structures of the devices fabricated by direct-printing process are defined by polyester films (base and cover) and by a toner layer (walls). The characterization of toner surface and composition were necessary for a better understanding of the chemistry composition and for this purpose we have used different techniques such as CHN-O elemental analysis, AFM, EDX and SEM. Besides the chemistry of toner, the possible dimensions for the channels as the depth and the width were also studied. The application of a gray-scale effect in the channels was evaluated in order to create a preconcentration device using the toner particles as obstacles for the flow. The polyester-toner microdevices were coupled with end-channel amperometric detection using electrodes produced by combination of the toner masks laser-printing and compact discs as a gold source. The performance of this electrophoresis microchip was evaluated by amperometric detection of iodide and ascorbate. The detection limits found were 500 nmol L-1 (135 amol) and 1.2 mmol L-1 (486 amol) for iodide and ascorbate, respectively. Besides the direct-printing process, the photolithographic process was also used for this purpose. In this process it was used the SU-8 negative photoresist and microdevices with 1-cm2 area were fabricated using different substrates such as glass, silicon and alumina. The alumina presented several irregularities for the microdevices fabricated. Problems with the absorption and dispersion of ultraviolet radiation were observed. However, the alumina was an excellent material for the steps in the production of two metallic molds for fast production of PDMS devices. One mold with complex geometry was obtained in order to study a new injection system and a second mold was prepared to evaluate the use of silicon rubber as molding material. Furthermore, in this work it was also reported the development of a microfabricated device with fully integrated electrodes for separation and electrochemical detection. The gold or titanium/platinum electrodes were obtained by lift-off technique. The masks for fabrication of the metallic molds and of the integrated microdevices were prepared in transparency films with high resolution.
3

Detecção condutométrica sem contato (oscilométrica) para eletroforese capilar de zona e cromatografia micelar eletrocinética / Contactless conductivity detection for capillary zone electrophoresis and micellar electrokinetic chromatography

José Alberto Fracassi da Silva 19 March 2001 (has links)
Este trabalho descreve a construção e avaliação de um detector condutométrico sem contato (oscilométrico) para sua aplicação em eletroforese capilar de zona e cromatografia micelar eletrocinética (MEKC). A construção do detector contou com a avaliação de diversos materiais e métodos para a confecção dos eletrodos, tão bem como o aperfeiçoamento do seu circuito eletrônico. O seu comportamento e desempenho foram verificados através do estudo dos diversos parâmetros que influenciam sua resposta, como freqüência e amplitude do sinal aplicado, temperatura e condutividade do meio. Além disso, a simulação do circuito equivalente da cela de detecção auxiliou no entendimento das propriedades do detector frente a alterações na condutividade do meio, na freqüência de operação e nas dimensões da cela. A otimização dos parâmetros operacionais foi racionalizada pela formulação de equações analíticas que descrevem o fator de resposta do detector a partir de parâmetros obtidos experimentalmente. Para o desenvolvimento do sistema de detecção, dois equipamentos completos de eletroforese capilar foram construídos. Sistemas de injeção de amostra por pressão, por gravidade, e eletrocinética foram desenvolvidos. Um dos equipamentos permite que a injeção da amostra seja feita do lado aterrado da fonte de alta tensão. Conseqüentemente, o detector é posicionado próximo do ponto de aplicação da alta tensão. Este é, de que se tem notícia, o primeiro sistema de detecção eletroquímico para eletroforese capilar com essa característica. A termostatização dos capilares foi efetuada por convecção forçada de ar. De maneira a aumentar o grau de automação e facilitar o seu manuseio, os dois equipamentos foram interfaceados a microcomputador. Os equipamentos de eletroforese com detecção oscilométrica construídos permitiram a análise de diversas substâncias em matrizes variadas, como por exemplo íons orgânicos e inorgânicos em água de chuva e material particulado, ácidos graxos de cadeia linear em gordura de coco, formaldeído na fase gasosa da atmosfera, e, pela primeira vez, espécies neutras, como álcoois alifáticos, separadas por MEKC. / This work describes the construction and evaluation of a contactless conductometric (or oscillometric) detector, for its application in capillary zone electrophoresis and micellar electrokinetic chromatography (MEKC). The materials and methods used for the construction of the electrodes, as well as the improvements on the electronic circuit, were evaluated. The behavior and performance of the detector were studied by changing the parameters that affect its response, e. g., the frequency and amplitude of the input signal, temperature and solution conductivity. The simulation of the cell equivalent electric circuit helped to understand the detector properties related to the variations in the solution conductivity, frequency, and cell dimensions. The optimization of the parameters was conducted by the formulation of analytical equations that describe the response factor using experimental data. For the detection development, two complete capillary electrophoresis equipments were constructed. Pressure, gravity, and electrokinetic sample injection systems were developed. One of the equipments allows the sample injection on the grounded side of the capillary. Consequently, the detector is placed near the high voltage application point. This is the first electrochemical detector described for capillary electrophoresis with this characteristic. The capillary thermostating was made by passing a forced air stream. Both equipments were interfaced to microcomputers. The capillary electrophoresis equipments with oscillometric detection were applied to the analysis of many types of compounds in different matrices, such as organic and inorganic ions in rainwater and particulate material, fatty acids in cocoa oil, formaldehyde in the atmosphere and, for the first time, neutral species, like aliphatic alcohols, separated by MEKC.
4

"Fabricação e avaliação de microdispositivos para eletroforese com detecção eletroquímica" / "Fabrication and Evaluation of Electrophoresis Microdevices coupled with Electrochemical Detection"

Wendell Karlos Tomazelli Coltro 03 September 2004 (has links)
Este trabalho descreve o desenvolvimento de microchips para eletroforese a partir dos processos de impressão direta e fotolitográfico. A estrutura dos microcanais fabricados pelo processo de impressão direta são definidos por filmes de poliéster (base e tampa) e por uma camada de toner (paredes). A caracterização da superfície e da composição do toner foram necessárias para um melhor entendimento da composição química da estrutura dos microcanais e para este propósito foram utilizadas diferentes técnicas como análise elementar de CHN-O, AFM, EDX e MEV. Além da química do toner as dimensões limites para os canais, como largura e altura, também foram estudadas. A aplicação de um efeito de cinza nos microcanais foi avaliado de modo a desenvolver um dispositivo de pré-concentração usando as partículas de toner como obstáculos para o fluxo. Os microdispositivos fabricados em poliéster-toner foram integrados com detecção amperométrica no final do canal de separação usando eletrodos produzidos a partir da combinação das tecnologias da produção de máscaras de toner e CDs, como fonte de ouro. O desempenho destes microchips foi avaliado com detecção amperométrica da separação eletroforética de iodeto e ascorbato. Os limites de detecção obtidos foram de 500 nmol L-1 (135 amol) e 1,2 mmol L-1 (486 amol) para o iodeto e ascorbato, respectivamente. Além do processo de impressão direta, o processo fotolitográfico também foi utilizado para a mesma finalidade. Neste processo foi utilizado o fotorresiste negativo SU-8 e microdispositivos com área de 1 cm2 foram fabricados usando diferentes substratos como vidro, silício e alumina. A alumina apresentou muitas irregularidades para os microdispositivos fabricados. Problemas com a absorção e dispersão da radiação ultravioleta foram observados. No entanto, a alumina foi um excelente material para as etapas de produção de dois moldes metálicos para a rápida produção de dispositivos poliméricos. Um molde com uma geometria complexa foi obtido para estudar um novo sistema de injeção e um segundo molde foi preparado para avaliar o uso de uma borracha de silicone como material moldante. Além disso, este trabalho também apresenta o desenvolvimento de um dispositivo microfabricado com eletrodos completamente integrados para separação e detecção eletroquímica. Eletrodos de ouro ou de titânio/platina foram obtidos através da técnica lift-off. As máscaras para a fabricação de moldes metálicos e dos dispositivos integrados foram preparadas em fotolito de alta resolução. / This work describes the development of electrophoresis microchip fabricated by direct-printing and photolithographic processes. The channel structures of the devices fabricated by direct-printing process are defined by polyester films (base and cover) and by a toner layer (walls). The characterization of toner surface and composition were necessary for a better understanding of the chemistry composition and for this purpose we have used different techniques such as CHN-O elemental analysis, AFM, EDX and SEM. Besides the chemistry of toner, the possible dimensions for the channels as the depth and the width were also studied. The application of a gray-scale effect in the channels was evaluated in order to create a preconcentration device using the toner particles as obstacles for the flow. The polyester-toner microdevices were coupled with end-channel amperometric detection using electrodes produced by combination of the toner masks laser-printing and compact discs as a gold source. The performance of this electrophoresis microchip was evaluated by amperometric detection of iodide and ascorbate. The detection limits found were 500 nmol L-1 (135 amol) and 1.2 mmol L-1 (486 amol) for iodide and ascorbate, respectively. Besides the direct-printing process, the photolithographic process was also used for this purpose. In this process it was used the SU-8 negative photoresist and microdevices with 1-cm2 area were fabricated using different substrates such as glass, silicon and alumina. The alumina presented several irregularities for the microdevices fabricated. Problems with the absorption and dispersion of ultraviolet radiation were observed. However, the alumina was an excellent material for the steps in the production of two metallic molds for fast production of PDMS devices. One mold with complex geometry was obtained in order to study a new injection system and a second mold was prepared to evaluate the use of silicon rubber as molding material. Furthermore, in this work it was also reported the development of a microfabricated device with fully integrated electrodes for separation and electrochemical detection. The gold or titanium/platinum electrodes were obtained by lift-off technique. The masks for fabrication of the metallic molds and of the integrated microdevices were prepared in transparency films with high resolution.
5

Novas tecnologias para fabricação de microsistemas analíticos e detecção eletroquímica / New technologies for the fabrication of microluidic devices with electrochemical detection

Piccin, Evandro 11 April 2008 (has links)
Este trabalho de doutorado apresenta o desenvolvimento de novas tecnologias para fabricação de microsistemas analíticos e detecção eletroquímica. Primeiramente, a poliuretana elastomérica, derivada de uma fonte renovável, o óleo de mamona, foi utilizada como um novo e alternativo material para fabricação de microdispositivos. Foram avaliadas as características físicas dos microcanais formados por moldagem, a compatibilidade química com solventes e eletrólitos, as características de superfície através dos ângulos de contato, o EOF em diferentes pHs e a performance analítica em experimentos de eletroforese com detecção eletroquímica. A segunda parte do trabalho apresenta o desenvolvimento de um método para a determinação simultânea de azo-corantes comumente usados na indústria alimentícia. Amaranto, amarelo crepúsculo FCF, amarelo sólido AB, ponceu 4R e vermelho 2G, foram separados e quantificados através de eletroforese em microdispositivos com detecção eletroquímica. Foram estudados e otimizados vários parâmetros que influenciaram a separação eletroforética e detecção eletroquímica, em experimentos realizados usando microdispositivos de vidro e eletrodo de trabalho de carbono vítreo. Finalmente, a terceira parte desse trabalho apresenta o uso das propriedades magnéticas e eletrocatalíticas de nanofios de níquel no desenvolvimento de um detector adaptativo magneticamente modulável para eletroforese em microdispositivos. / The development of microfluidic analytical systems has witnessed an explosive growth during the last 15 years. Particular attention has been given to microchip electrophoresis because of their fast and efficient separation capabilities. Electrochemistry detection offers considerable promise for such microfluidic systems, with features that include remarkable sensitivity, inherent miniaturization and portability, low cost, and high compatibility with microfabrication technologies. This thesis shows the development of new fabrication technologies for miniaturized analytical systems with electrochemical detection and it is presented in four chapters, Chapter I shows an introductory view of the main aspects related to miniaturization of analytical systems and amperometric detection configurations commonly coupled to microchip electrophoresis. In Chapter II, the use of elastomeric polyurethane (PU), derived from castor oil (CO) biosource, as a new material for fabrication of microfluidic devices by rapid prototyping is presented. Including the irreversible sealing step, PU microchips were fabricated in less than 1 h by casting PU resin directly on the positive high-relief molds fabricated by standard photolithography and nickel electrodeposition. Physical characterization of microchannels was performed by scanning electron microscopy (SEM) and profilometry. Polymer surface was characterized using contact angle measurements and the results showed that the hydrophilicity of the PU surface increases after oxygen plasma treatment. The polymer surface demonstrated the capability of generating an electroosmotic flow (EOF) of 2.6 × 10-4 cm2 V-1 s-1 at pH 7 in the cathode direction, which was characterized by current monitoring method at different pH values. The compatibility of PU with a wide range of solvents and electrolytes was tested by determining its degree of swelling over a 24 h period of contact. The performance of microfluidic systems fabricated using this new material was evaluated by fabricating miniaturized capillary electrophoresis systems. We used catecholamines as model analytes that were separated in aqueous solutions and detected with end-channel amperometric detection. In Chapter III, a method based on microchip electrophoresis with electrochemical detection has been developed for the simultaneous determination of Yellow AB, Red 2G, Sunset Yellow, Ponceu 4R, and Amaranth which are azo-dyes frequently added to foodstuffs. Factors affecting both separation and detection processes were examined and optimized, with best performance achieved by using a 10 mM phosphate buffer (pH 11) as running buffer and applying a voltage of 2500 V both in the separation and in the electrokinetic injection (duration 4 s). Under these optimal conditions, the target dye analytes could be separated and detected within 300 s by applying a detection potential of -1,0 V (vs. Ag/AgCl) to the glassy carbon (GC) working electrode. The recorded peaks were characterized by a good repeatability (RSD = 1,8 - 3,2%), high sensitivity, and a wide linear range. Detection limits of 3.8, 3.4, 3.6, 9.1, 15.1 ?M were obtained for Yellow AB, Red 2G, Sunset Yellow, Ponceu 4R, and Amaranth, respectively. Fast, sensitive, and selective response makes the new microchip protocol very attractive for the quantitative analysis of commercial soft drinks and candies Finally, in Chapter IV, we demonstrate for the first time the use of adaptive functional nickel nanowires for switching on demand operation of microfluidic devices. Controlled reversible magnetic positioning and orientation of these nanowires at the microchannel outlet offers modulation of the detection and separation processes, respectively. The former facilitates switching between active and passive detection states to allow the microchip to be periodically activated to perform a measurement and reset it to the passive (\"off\") state between measurements. Fine magnetic tuning of the separation process (post channel broadening of the analyte zone) is achieved by reversibly modulating the nanowire orientation (i.e., detector alignment) at the channel outlet. The concept can be extended to other microchip functions and stimuli-responsive materials and holds great promise for regulating the operation of microfluidic devices in reaction to specific needs or unforeseen scenarios.
6

Desenvolvimento de metodologia eletroanalítica para a determinação do herbicida glifosato / Development of electroanalytic methodology for determination of the herbicide glyphosate

Coutinho, Cláudia Flávia Breda 22 August 2008 (has links)
Neste trabalho, são abordados os estudos relativos a interação entre Cu(II) e glifosato e também o desenvolvimento de metodologias eletroanalíticas para determinação do herbicida glifosato. Inicialmente, o complexo Cu(II)-glifosato foi estudo por meio de técnicas espectrofotométricas e eletroanalíticas (voltametria de onda quadrada) e encontrou-se os valores de comprimento de onda máximo do complexo (231 e 731 nm) e também o valor da constante de estabilidade condicional do complexo 1:1 Cu(II)-glifosato (log K = 7,9). O estudo inicial da interação entre glifosato e o microeletrodo de cobre, em meio de tampão fosfato, mostrou que o herbicida dissolve a camada de óxidos, aumentando a corrente anódica do microeletrodo, levando a formação de um complexo solúvel entre Cu(II) e glifosato. Esta interação foi estuda por meio de técnicas voltamétricas, curvas de polarização, espectroscopia de impedância eletroquímica, voltametria hidrodinâmica, entre outras. Estes estudos complementares forneceram dados importantes sobre o processo de dissolução causado pelo glifosato, tais como, potencial de corrosão, densidade de corrente de corrosão e inclinação de Tafel, valores de resistência de transferência de carga e constante aparente de transferência eletrônica, coeficiente de difusão do complexo e constante de velocidade aparente da reação, além de imagens de microscopia eletrônica de varredura e de microscopia de força atômica do processo de corrosão do cobre. Após estudar este processo de dissolução, esta reação foi utilizada para o desenvolvimento de uma metodologia de análise de glifosato utilizando detecção coulométrica com (micro)eletodo de cobre aliada a cromatografia líquida. A instrumentação (software, célula eletroquímica e minipotenciostato) desenvolvida neste trabalho foi utilizada com sucesso na determinação de glifosato em amostras de alimentos e água. As metodologias de análise de glifosato utilizando detecção coulométrica com (micro)eletrodo de cobre aliada a cromatografia liquida, apresentaram limites de detecção adequados para a análise deste herbicida em diversas matrizes (100 µg L-1 para sucos de frutas, 32 µg L-1 e 1,9 µg L-1 para amostras de água e 53 µg Kg-1 para amostras de soja). A detecção coulométrica com micro(eletrodo) de cobre apresentou algumas vantagens sobre a detecção com métodos ópticos, tais como, análise direta e rápida, ou seja, não são necessárias demoradas reações de derivatização da amostra; sem etapas de extração/limpeza da amostra; pré-concentração optativa; baixo custo das análises, quando comparado aos preços dos reagentes de derivatização e instrumentação simples e de baixo custo. / In this work, the interaction between Cu(II) and glyphosate was investigated and electroanalytical methodologies was developed for determination of this herbicide. Initially, the Cu(II)-glyphosate complex was studied through spectrophotometric and electroanalytical techniques (square wave voltammetry) and it was found the values of maximum wavelength of the complex (231 and 731 nm) and also the value for the constant of conditional stability of the 1:1 Cu(II)-glyphosate complex (log K = 7,9). The initial study of the interaction between glyphosate and the copper microelectrode, in phosphate buffer, showed that the herbicide dissolves the layers of oxides, increasing the anodic current of the microelectrode, taking the formation of a soluble complex between Cu(II) and glyphosate. This interaction was studies through cyclic voltammetry, polarization curves, electrochemical impedance espectroscopy, hydrodynamic voltammetry, among others. These complemental studies supplied important data about the electrode dissolution process caused by glyphosate, such as, corrosion potential, density of corrosion current and Tafel slope, resistance of heterogeneous charge-transfer reaction, diffusion coefficient of the complex and apparent rate constant of reaction, besides images of scanning electron microscopy and of atomic force microscopy of the corrosion process for metallic copper. After studying the copper dissolution process, this reaction was used for the development of a new methodology for glyphosate analysis using coulometric detection with copper microelectrode allied to the liquid chromatography The instrumentation (software, electrochemical cell and a minipotentiostat) developed in this work was used with success in the determination of glyphosate in samples of foods and water. The methodologies of glyphosate analysis using coulometric iv detection with copper microelectrode allied to the liquid chromatography, presented appropriate detection limits for the analysis of this herbicide in several matrixes (100 µg L-1 for fruit juices, 32 µg L-1 and 1,9 µg L-1 for water samples and 53 µg Kg-1 for soy samples). The coulometric detection with copper microelectrode presented some advantages when compared with the detection with optical methods, such as, direct and fast analysis, in other words, it is not necessary derivatization reaction of the sample; without extraction/clean-up step of the sample; the sample pre-concentration is optional; low cost of the analyses, when compared to the prices of the derivatization reagents and simple and low cost instrumentation.
7

Eletrodos de diamante dopado com boro como ferramenta de detecção na interface biodiesel/eletrólito de suporte

Maynart, Marlon Cavalcante January 2009 (has links)
Orientador: Hugo Barbosa Suffredini / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-graduação em Ciência e Tecnologia/Química.
8

Avanços instrumentais e desenvolvimento de metodologia analítica para separação de monossacarídeos em microssistemas eletroforéticos com detecção condutométrica sem contato / Instrumental advances and development of analytical method for monosaccharide electrophoretic separation in microhips with contactless conductivity detection

Duarte Junior, Gerson Francisco 06 July 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-02-17T14:00:34Z No. of bitstreams: 2 Dissertação - Gerson Francisco Duarte Júnior - 2015.pdf: 3229718 bytes, checksum: 81bfec5942eb1f9b2ce2a8218a18cdba (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-18T11:48:18Z (GMT) No. of bitstreams: 2 Dissertação - Gerson Francisco Duarte Júnior - 2015.pdf: 3229718 bytes, checksum: 81bfec5942eb1f9b2ce2a8218a18cdba (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-02-18T11:48:18Z (GMT). No. of bitstreams: 2 Dissertação - Gerson Francisco Duarte Júnior - 2015.pdf: 3229718 bytes, checksum: 81bfec5942eb1f9b2ce2a8218a18cdba (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-07-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The current work describes some instrumental advances on contactless conductivity detection (C4D) as well as the development of ionic electrodes to be coupled on microchips electrophoresis (MSE). Firstly, was constructed a high-resolution C4D detector based on openC4D electronic. Frequency and amplitude was optimized resulting in 400 kHz and 4 Vpp, respectively, for optimal values. These conditions was able to be used in different MSE devices including polymethylmethacrylate, polydimethysiloxane and polyester-toner. For liquid electrodes fabrication, channels were engraved on a polymeric plate using a CO2 laser system and sealed with adhesive membrane. After that, PDMS microchip was reversibly sealed against the polymer membrane. The electrode channels were filled with different ionc solutions (KCl, NaCl and LiCl). The KCl solution with 2 mol/L provide the best peak intensity. Then analytical performance of the ionic electrode was test in a separation of K+, Na+ e Li+ (300 μmo/L each). A good separation was observed and limit of detection achieved were 28, 40 and 58 μmol/L for K+, Na+ e Li+, respectively. The biggest advantage the use of ionic electrode are related of easiness fabrication process, simplicity and lower cost per device. Additionally, a commercial system of MSE-C4D was propose in a separation of sugars. The analytical separation was realized under the alkaline condition (pH>12), in order to provide the negative charge for sugars. After optimization of buffer and experimental conditions, a mixture containing fructose, galactose, glucose, lactose and sucrose was separated in less 3 min. / O presente trabalho descreve alguns avanços instrumentais relacionados à construção de um detector condutométrico de alta resolução e também ao uso de eletrodos iônicos para detecção condutométrica sem contato (C4D) acoplada aos microssistemas eletroforéticos (MSE). Além disso, o trabalho também descreve o desenvolvimento de metodologia para a análise de açúcares voltadas à aplicações na produção do etanol de 2ª geração. Inicialmente, foi construído e otimizado um detector condutométrico para MSE baseado na eletrônica OpenC4D. Os valores de frequência e amplitude obtidos com a otimização foram de 400 kHz e 4 Vpp, respectivamente. Com os valores otimizados, o detector se mostrou versátil ao utilizá-lo em MSE fabricados em diferentes substratos. Para a construção dos eletrodos iônicos, primeiramente foram gravados canais em placas poliméricas e selados com uma membrana adesiva. Um microchip de PDMS foi selado reversivelmente contra este suporte. Em comparação aos eletrodos metálicos, os eletrodos iônicos oferecem algumas vantagens, tais como, simplicidade, facilidade de fabricação, e baixo custo por dispositivo. Diferentes soluções foram avaliadas como eletrodos, dentre as quais a solução de KCl 2 mol/L forneceu os melhores resultados em termos de intensidade de sinal. O desempenho analítico dos novos eletrodos foi avaliado para a separação de uma mistura padrão de K+, Na+ e Li+ (300 μmol/L cada). Neste estudo, foram obtidos limites de detecção entre 28 e 58 μmol/L. Estes valores são comparáveis aos obtidos com os convencionais eletrodos metálicos. Uma metodologia para separação de frutose, glicose e sacarose utilizando um sistema comercial de MSE-C4D foi proposta. As análises foram baseadas na utilização de um pH alcalino (>12) que garante a ionização destas espécies para a forma aniônica. Após a otimização das condições experimentais onde um tampão composto por NaOH/Na2HPO4 75/10 mmol/\L foi o que forneceu melhores resultados em temos de resolução entre par frutose e glicose. com estas condições uma mistura contendo frutose, galactose, glicose, lactose e sacarose foi separada em um tempo de 3 min.
9

Desenvolvimento de um biossensor para detecção e identificação do vírus da dengue em flúidos biológicos

Sérgio Rodrigues Ribeiro Teles, Fernando January 2006 (has links)
Made available in DSpace on 2014-06-12T15:54:27Z (GMT). No. of bitstreams: 2 arquivo5235_1.pdf: 2382932 bytes, checksum: 437319d0a3295226bd180cfe0dcb9104 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / A dengue, uma doença emergente, é atualmente a mais importante arbovirose humana, manifestando-se na forma de quatro sorotipos relacionados antigenicamente (DENV 1-4). É endêmica e / ou epidêmica em todas as regiões tropicais e subtropicais, e uma ameaça potencial para regiões mais temperadas. Dos 100 milhões de casos anuais, 450000 correspondem à forma mais grave, hemorrágica, com alta letalidade. Devido à inespecificidade dos sintomas iniciais e à inexistência de vacinas e drogas eficientes e devidamente testadas, o diagnóstico precoce é a principal estratégia de sobrevivência à dengue hemorrágica. As técnicas laboratoriais de diagnóstico clínico convencional, contudo, apresentam limitações significativas. Com a tecnologia de biossensores produzem-se dispositivos simples, rápidos, baratos, sensíveis, específicos e miniaturados para diagnóstico descentralizado. Neste trabalho, desenvolveu-se um biossensor eletroquímico de DNA para detectar, por voltametria cíclica, um oligonucleotídeo sintético relacionado com o genoma do vírus da dengue, hibridizandoo especificamente com a sua seqüência complementar, imobilizada num eletrodo de carbono vítreo modificado com quitosana. O ferroceno foi usado como indicador eletroativo de hibridização por se ligar ao ssDNA e ao dsDNA com diferentes afinidades e, assim, gerar picos de corrente distintos. Este biossensor conseguiu discriminar significativamente o dsDNA do ssDNA, na gama de detecção de mg/ml (submicromolar). A maior afinidade relativa do ferroceno por dsDNA foi confirmada pela obtenção de maior constante de decaimento voltamétrico (kd) e menor período de meia-vida (t1/2) em relação ao ensaio com ssDNA. A identificação específica do sorotipo deverá requerer somente substituição da seqüência conservada (genérica) por seqüências específicas de cada sorotipo
10

Desenvolvimento de metodologia eletroanalítica para a determinação do herbicida glifosato / Development of electroanalytic methodology for determination of the herbicide glyphosate

Cláudia Flávia Breda Coutinho 22 August 2008 (has links)
Neste trabalho, são abordados os estudos relativos a interação entre Cu(II) e glifosato e também o desenvolvimento de metodologias eletroanalíticas para determinação do herbicida glifosato. Inicialmente, o complexo Cu(II)-glifosato foi estudo por meio de técnicas espectrofotométricas e eletroanalíticas (voltametria de onda quadrada) e encontrou-se os valores de comprimento de onda máximo do complexo (231 e 731 nm) e também o valor da constante de estabilidade condicional do complexo 1:1 Cu(II)-glifosato (log K = 7,9). O estudo inicial da interação entre glifosato e o microeletrodo de cobre, em meio de tampão fosfato, mostrou que o herbicida dissolve a camada de óxidos, aumentando a corrente anódica do microeletrodo, levando a formação de um complexo solúvel entre Cu(II) e glifosato. Esta interação foi estuda por meio de técnicas voltamétricas, curvas de polarização, espectroscopia de impedância eletroquímica, voltametria hidrodinâmica, entre outras. Estes estudos complementares forneceram dados importantes sobre o processo de dissolução causado pelo glifosato, tais como, potencial de corrosão, densidade de corrente de corrosão e inclinação de Tafel, valores de resistência de transferência de carga e constante aparente de transferência eletrônica, coeficiente de difusão do complexo e constante de velocidade aparente da reação, além de imagens de microscopia eletrônica de varredura e de microscopia de força atômica do processo de corrosão do cobre. Após estudar este processo de dissolução, esta reação foi utilizada para o desenvolvimento de uma metodologia de análise de glifosato utilizando detecção coulométrica com (micro)eletodo de cobre aliada a cromatografia líquida. A instrumentação (software, célula eletroquímica e minipotenciostato) desenvolvida neste trabalho foi utilizada com sucesso na determinação de glifosato em amostras de alimentos e água. As metodologias de análise de glifosato utilizando detecção coulométrica com (micro)eletrodo de cobre aliada a cromatografia liquida, apresentaram limites de detecção adequados para a análise deste herbicida em diversas matrizes (100 µg L-1 para sucos de frutas, 32 µg L-1 e 1,9 µg L-1 para amostras de água e 53 µg Kg-1 para amostras de soja). A detecção coulométrica com micro(eletrodo) de cobre apresentou algumas vantagens sobre a detecção com métodos ópticos, tais como, análise direta e rápida, ou seja, não são necessárias demoradas reações de derivatização da amostra; sem etapas de extração/limpeza da amostra; pré-concentração optativa; baixo custo das análises, quando comparado aos preços dos reagentes de derivatização e instrumentação simples e de baixo custo. / In this work, the interaction between Cu(II) and glyphosate was investigated and electroanalytical methodologies was developed for determination of this herbicide. Initially, the Cu(II)-glyphosate complex was studied through spectrophotometric and electroanalytical techniques (square wave voltammetry) and it was found the values of maximum wavelength of the complex (231 and 731 nm) and also the value for the constant of conditional stability of the 1:1 Cu(II)-glyphosate complex (log K = 7,9). The initial study of the interaction between glyphosate and the copper microelectrode, in phosphate buffer, showed that the herbicide dissolves the layers of oxides, increasing the anodic current of the microelectrode, taking the formation of a soluble complex between Cu(II) and glyphosate. This interaction was studies through cyclic voltammetry, polarization curves, electrochemical impedance espectroscopy, hydrodynamic voltammetry, among others. These complemental studies supplied important data about the electrode dissolution process caused by glyphosate, such as, corrosion potential, density of corrosion current and Tafel slope, resistance of heterogeneous charge-transfer reaction, diffusion coefficient of the complex and apparent rate constant of reaction, besides images of scanning electron microscopy and of atomic force microscopy of the corrosion process for metallic copper. After studying the copper dissolution process, this reaction was used for the development of a new methodology for glyphosate analysis using coulometric detection with copper microelectrode allied to the liquid chromatography The instrumentation (software, electrochemical cell and a minipotentiostat) developed in this work was used with success in the determination of glyphosate in samples of foods and water. The methodologies of glyphosate analysis using coulometric iv detection with copper microelectrode allied to the liquid chromatography, presented appropriate detection limits for the analysis of this herbicide in several matrixes (100 µg L-1 for fruit juices, 32 µg L-1 and 1,9 µg L-1 for water samples and 53 µg Kg-1 for soy samples). The coulometric detection with copper microelectrode presented some advantages when compared with the detection with optical methods, such as, direct and fast analysis, in other words, it is not necessary derivatization reaction of the sample; without extraction/clean-up step of the sample; the sample pre-concentration is optional; low cost of the analyses, when compared to the prices of the derivatization reagents and simple and low cost instrumentation.

Page generated in 0.0887 seconds