• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 15
  • 15
  • 11
  • 9
  • 8
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da capacidade de limpeza e biocompatibilidade de diferentes soluções irrigadoras utilizadas em Endodontia /

Gomes, Laís Carolina Landim. January 2018 (has links)
Orientador: Marcia Carneiro Valera / Coorientador: Carlos Henrique Ribeiro Camargo / Banca: Cláudio Antonio Talge Carvalho / Banca: Marco Antônio Húngaro Duarte / Resumo: Os objetivos deste estudo foram: Artigo 1 - Analisar a extrusão apical de hipoclorito de sódio (NaOCl), debris e sua citotoxicidade após o preparo dos canais radiculares utilizando NaOCl líquido ou gel. Artigo 2- avaliar a dissolução de matéria orgânica do NaOCl líquido e gel, e a limpeza das paredes dentinárias após a instrumentação; Métodos: Artigo 1 - A avaliação da extrusão apical de NaOCl e debris foi feita pela espectrofotometria do conteúdo extruído após o preparo biomecânico. A citotoxicidade foi avaliada pela resposta de culturas celulares de fibroblastos de ligamento periodontal (PDFL) frente as soluções irrigadoras extruídas, pelo teste XTT para análise da viabilidade celular. Para isso, oitenta dentes foram instrumentados com limas Reciproc #25 e #40 (VDW Munique, Alemanha) e utilizado NaOCl gel e líquido ativados por ultrassom. Os dados foram analisados estatisticamente pelo teste de ANOVA e as diferenças estatísticas pelo teste de Tukey e Dunn (p<0,05). Artigo 2 - A dissolução de matéria orgânica foi realizada usando cubos de carne com tamanho e peso determinado, os quais foram deixados em contato com 1 mL das amostras dos seguintes grupos: NaOCl gel 3% (ChlorCid V); NaOCl gel 3%(VIM); NaOCl líquido 2,5%; NaOCl líquido 5,25%; Solução fisiológica estéril (SF) (controle) por um período de 3 min, os fragmentos foram removidos e pesados novamente para quantificar a matéria orgânica não dissolvida. A comprovação da limpeza das paredes dos canais foi avaliada através ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objectives of this study were: Article 1 - Analyze the apical sodium hypochlorite (NaOCl) extrusion, debris and it's cytotoxicity after the root canals preparation using liquid or gel NaOCl. Article 2 - Evaluate the tissue dissolution of NaOCl liquid and gel, and it's cleaning efficiency of dentin walls after instrumentation; Methods: Article 1 - The evaluation of the apical extrusion of NaOCl and debris was done by the spectrophotometry of the extruded contents after the biomechanical preparation. Cytotoxicity was evaluated by the cell cultures response of periodontal ligament fibroblasts (PDFL) against extruded irrigation solutions by the XTT test for cell viability analysis. For this, eight teeth were instrumented with Reciproc # 25 and # 40 files (VDW Munich, Germany) and used NaOCl gel and liquid activated by ultrasound. Data were analyzed statistically by the ANOVA test and the statistical differences by the Tukey and Dunn test (p <0.05). Article 2 - The dissolution of organic matter was carried out using meat cubes of determined size and weight, which were left in contact with 1 mL of samples from the following groups: NaOCl gel 3% (ChlorCid V); NaOCL gel 3% (VIM); NaOCl liquid 2.5%; NaOCl liquid 5.25%; Sterile physiological solution (SP) (control) for a period of 3 min, the fragments were removed and weighed again to quantify the undissolved organic matter. The verification of the cleansing of the canal walls was evaluated through the SEM and the stereomicroscopy ... (Complete abstract click electronic access below) / Mestre
2

Avaliação microbiológica e quantificação de raspas extruídas por instrumentos reciprocantes e rotatórios com variação no calibre e na irrigação ultrassônica passiva / Microbiological evaluation and quantification of extruded debris by reciprocating and rotating instruments with variation in caliber and passive ultrasonic irrigation

Cardenas Cuellar, Maricel Rosario 28 March 2018 (has links)
Foi objetivo deste estudo, avaliar comparativamente o volume dos debris e a extrusão bacteriana apical durante o preparo de canais radiculares com os instrumentos Prodesign R e Prodesign Logic, com diferentes calibres e presença de irrigação ultrassônica passiva (PUI) ou não, em dentes contaminados com Enterococcus faecalis (ATCC29212). Métodos: Foram empregados 90 pré-molares inferiores, decoronados e padronizados em 16 mm, divididos em 8 grupos (n=10) segundo os sistemas a serem empregados; Prodesign Logic 25.06, 35.05, Prodesign R 25.06 e 35.05, e o tipo de ativação do irrigante, contaminados durante 5 dias. Debris extruídos foram coletados em microtubos vazios pesados previamente 3 vezes, inseridos na parte inferior de um dispositivo metálico para uma posterior pesagem dos debris. Também foram realizadas coletas dos canais e dos debris extruídos para uma avaliação microbiológica através da contagem das unidades formadoras de colônias (UFC/mL). Resultados: O tipo de movimento rotatório e reciprocante e o diâmetro do calibre, 25 ou 35, não mostraram diferenças entre si (P>0.05). Comparando a irrigação convencional com o emprego do ultrassom, este último promoveu uma maior quantidade de debris extruídos pelo forame (P<0.05). Na análise microbiológica das coletas dos debris, o sistema Prodesign Logic 25 promoveu uma maior quantidade de raspas contaminadas (P<0.05). Nas coletas dos canais tanto a irrigação convencional quanto o uso do ultrassom mostraram uma diminuição das UFC/mL das coletas iniciais comparadas com as finais, sem diferença estatística (P<0.05). A contaminação microbiana nas raspas extruídas foi menor no grupo onde foi empregada a irrigação convencional (P<0.05). Conclusões: Os calibres dos instrumentos e o tipo de movimento utilizado nos canais radiculares agiram de forma semelhante, diminuindo a contaminação do canal principal e extruindo a mesma quantidade de debris, com a mesma contaminação. A PUI aumentou a extrusão e a contaminação dos debris dentinários em comparação com a irrigação convencional. / The main of this study was to compare the volume of debris and apical bacterial extrusion during root canal preparation with the Prodesign R and Prodesign Logic instruments, with different calibers and presence of passive ultrasonic irrigation (PUI) or not, in teeth contaminated with Enterococcus faecalis (ATCC29212). Methods: 90 lower premolars were used, decoronated and standardized in 16 mm, divided into 8 groups (n = 10) according to the systems to be used; Prodesign Logic 25.06, 35.05, Prodesign R 25.06 and 35.05, and the type of irrigant activation, contaminated for 5 days. Extruded debris were collected in empty microtubes previously weighed 3 times, inserted in the inferior part of a metallic device for a later weighing of the debris. Samples of main root canals were also collected in addition of debris for a microbiological evaluation of colony forming units (CFU / mL). Results: The movement, rotational or reciprocating, and the diameter of the caliber, 25 or 35, showed no differences between them (P> 0.05). Comparing conventional irrigation with the use of ultrasound, the latter promoted a greater amount of debris extruded through the foramen (P <0.05). In the microbiological analysis of the debris collections, the Prodesign Logic 25 system promoted a greater amount of contaminated debris (P <0.05). I In the collections of the root canal both the conventional irrigation and the ultrasonic agitation showed a decrease of the CFU / mL from initial collections compared to the finals, with no statistical difference (P <0.05). Microbial contamination in the extruded debris was lower in the group where conventional irrigation was used (P <0.05). Conclusions: The instrument, caliber and the type of movement used in root canals acted similarly, reducing the contamination of the main root canal and extruding the same amount of debris, with the same contamination. PUI increased the extrusion and contamination of dentinal debris compared to conventional irrigation.
3

Análise comparativa \'in vitro\' da extrusão apical de dentina produzida por diferentes técnicas de instrumentação manuais e rotatórias nos canais radiculares / Comparative analysis of dentin apical extrusion through different manual and rotary instrumentation root canal technique

Costa, Clarice Fernandes Eloy da 16 April 2007 (has links)
No tratamento endodôntico nos deparamos com a necessidade de privar pelo bom estado pós-operatório do paciente. Dessa forma, devemos minimizar os efeitos que uma instrumentação pode causar sobre os tecidos periapicais. Nesse dilema, o presente estudo tem como objetivo comparar a quantidade de material sólido extruído além do forame apical através de duas técnicas de instrumentação manuais: técnica Step-Back ou Escalonada regressiva e técnica de Oregon e três técnicas de instrumentação mecânicorotatórias preconizadas pelos fabricantes dos instrumentos: Sistema ProTaper, Sistema K3 Endo e Sistema FKG RaCeTM. Setenta e cinco dentes unirradiculados foram utilizados, sendo 15 dentes para cada técnica. O material sólido extruído foi coletado por um filtro de papel (Whatman®). Tais filtros foram, após a instrumentação, submetidos a secagem em estufa e posterior pesagem em balança digital de alta precisão. A massa de resíduo extruído foi dada pela diferença entre a massa inicial e a massa final. A análise dos resultados mostrou extrusão de material sólido além do forame apical em todas as técnicas de instrumentação utilizadas, porém foi observado que a técnica Step-Back promoveu maior quantidade de material extruído quando comparada às outras técnicas e que não houve diferença significante entre as técnicas de Oregon e as dos Sistemas rotatórios. As técnicas foram assim classificadas em ordem crescente de material sólido extruído além do forame apical: Sistema K3 Endo, Sistema ProTaper, Sistema FKGRaCe, técnica de Oregon e Técnica Step Back. / Patient\'s general health is fundamental during endodontic therapy. Thus, we must minimize the harmful instrumentation effects in the periapical tissues. The aim of this study was to compare the amount of solid material extruded beyond the apical foramen among 2 manual instrumentation techniques: Step-Back and the Oregon\'s technique, as well as 3 mechanorotary techniques preconized by the manufacturers of the following instruments: ProTaper, K3 Endo, and FKG RaCeTM Systems. Seventy-five unirradicular teeth were used, being 15 teeth in each technique. The solid material extruded was collected with a paper filter (Whatman). Afterward, the filters were dry in the oven and weighted in an analytical balance. The extruded material was considered as the difference between final and initial mass values. Data analysis showed extrusion for all instrumentation techniques; however, the Step-back technique provided greater values than the other techniques, and no differences were seen among the Oregon and the rotary techniques. Progressive classification for the extruded material was the following: K3 Endo, ProTaper, FKGRaCe, Oregon, and The Step-back technique.
4

Comparação do transporte, centralização e extrusão apical de detritos após o uso de sistemas de NiTi em canais radiculares curvos

Boijink, Daiana January 2018 (has links)
Introdução: Os objetivos do presente estudo foram comparar a extrusão apical de detritos durante o preparo apical #25 com os sistemas Twisted File Adaptive (TFA), WaveOne Gold (WOG) e técnica manual (TM), registrar o tempo de preparo; e comparar WOG com TFA em relação ao transporte do canal radicular (TCR) e centralização (CR) com diâmetros apicais #25 e #35. Metodologia: Quarenta e cinco canais mésio-vestibulares de molares inferiores foram preparados e divididos em 3 grupos (n=15) para avaliar extrusão apical. A extrusão de detritos foi quantificada subtraindo-se o peso final do peso inicial dos tubos Eppendorf. TCR e CR foram avaliados em micro-TC com os sistemas TFA e WOG (n=15). A normalidade dos valores obtidos para cada grupo foi verificada usando teste de Kolmogorov-Smirnov. Para quantificar detritos extruídos e tempo de preparo, os dados foram paramétricos, sendo utilizado o Teste ANOVA de 1 via e post hoc de Tukey’s. Para avaliar TCR e CR, o teste estatístico foi Mann Whitney e Wilcoxon (α=.05). Resultados: Em relação aos detritos, o sistema WOG foi associado com menos extrusão em comparação com TM (P<0,05) ou com o sistema TFA (P> 0,05). O tempo de preparo exigido pela TM foi significativamente maior do que o exigido pelas outras técnicas (P<0,05). Não foram encontradas diferenças estatisticamente significantes entre WOG e TFA em relação à centralização em todos os níveis, quando usado diâmetro apical #25 ou #35 (P> 0,05). Para TCR, diferença significativa foi encontrada entre TFA e WOG a 1 e 7mm com diâmetro apical #25 e #35 (P<0,05). Foi encontrada diferença significante para TFA em 4mm, quando os diâmetros apicais #25 e #35 foram avaliados no mesmo sistema (P <0,05). Conclusões: Todos os sistemas de instrumentação causaram extrusão de detritos apicais em algum grau. TFA e WOG podem ser usados em canais radiculares curvos com segurança com diâmetros apicais# 25 ou 35. / Introduction: The aims of this study were to assess the amount of apically debris during root canal preparation with apical size #25 with the Twisted File Adaptive system (TFA), WaveOne Gold system (WOG) and manual technique (MT), and recorded working time; and to assess WOG with TFA in relation to root canal transportation (RCT) and centering ratio (CR) with apical diameters # 25 and # 35. Methods: Forty-five mesiobuccal root canals of mandibular molars were prepared and assigned into 3 groups (n = 15) to evaluate apical extrusion. Debris extrusion was quantified by subtracting the final from the initial weight of the Eppendorf tubes. RCT and CR were evaluated in Micro-TC with the TFA and WOG systems (n = 15). The normality values obtained for each group were tested using the Kolmogorov-Smirnov test. To quantify extruded debris and preparation time, the data were parametric, using the Tukey's 1-way and post-hoc ANOVA test. To evaluate RCT and CR, the statistical test was Mann Whitney (α =.05). Results: The WaveOne Gold reciprocating single-file system was associated with less extrusion of debris compared with hand files (P < 0.05) or with the Twisted File Adaptive system (P > 0.05). The preparation time required by hand files was significantly longer than that required by the other techniques (P < 0.05). No significant differences were found between WOG and TFA regarding CR for all levels when used #25 or #35 apical size preparation (p>0.05). For RCT, significant difference was found among TFA and WOG at 1 mm and 7 mm with diameter apical #25 and #35. (p<0.05). Statistically different for the TFA in 4 mm was observed when the apical diameters # 25 and # 35 was evaluated in the same system (P <0,05). Conclusions: All of the instrumentation systems caused apical debris extrusion to some degrees. TFA and WOG can be used in curved root canals with safety with #25 or 35 apical diameters.
5

Avaliação quantitativa e qualitativa da extrusão apical em técnicas de obturação termoplastificada. / Quantitative and qualitative evaluation of the apical extrusion in techniques of thermoplasticized obturation.

Strefezza, Fábio 29 March 2004 (has links)
Atualmente, as técnicas de obturação com guta-percha termoplastificada têm mostrado eficiência na adaptação dos materiais obturadores às paredes do sistema de canais radiculares, promovendo um selamento tridimensional. Porém, com a utilização destas técnicas, há dificuldade no controle longitudinal durante a obturação, que poderia acarretar em extrusão do material obturador em direção aos tecidos perirradiculares, influenciando na reparação pós tratamento endodôntico. Assim, o propósito deste estudo foi avaliar in vitro a extrusão apical de quatro técnicas de obturação termoplastificada, Thermafil, Obtura II, Ultrafil 3D e Fusionada, através de uma nova metodologia de mensuração de volume do material obturador extruído, relacionando com a freqüência da extrusão visual de guta-percha e/ou cimento e a qualidade radiográfica final da obturação. Os resultados demonstraram que a metodologia do sistema de mensuração foi efetiva para quantificar o volume de material obturador extruído, constatando extrusão em todas as técnicas termoplastificadas empregadas neste estudo, porém, quantitativamente, os grupos experimentais não apresentaram diferenças estatisticamente significantes entre as médias de volumes. Na avaliação radiográfica da qualidade final das obturações termoplastificadas, há evidências de que a técnica Obtura II produziu obturações endodônticas com qualidades estatisticamente inferiores às demais técnicas. De modo geral, podemos considerar que as técnicas Thermafil, Ultrafil 3D e Fusionada apresentaram resultados semelhantes em relação ao volume do material obturador extruído e qualidade radiográfica final da obturação, enquanto que as técnicas Thermafil e Fusionada exibiram resultados mais favoráveis em relação à freqüência da extrusão visual de guta-percha e/ou cimento. / In the present, the obturation techniques with termoplasticized gutta-percha have been proving efficiency in adaptation of the filling material to the walls of the root canal system, promoting a three-dimensional sealing. Even so, with the use of these techniques, there is difficulty in the longitudinal control during the obturation, that could cause the extrusion of the filling material in direction to the perirradicular tissues, influencing the healing after endodontic treatment. Thus, the purpose of this study was to evaluate in vitro the apical extrusion of four thermoplasticized obturation techniques, Thermafil, Obtura II, Ultrafil 3D and Fused, with a new methodology of volume?s measurement of the extruded filling material, relating with the frequency of the visual extrusion of gutta-percha and/or sealer and the final radiographic\'s quality of obturation. The results demonstrated that the methodology of the measurement system was effective to quantify the volume of the extruded filling material, verifying extrusion in all the thermoplasticized techniques studied, even so, quantitatively, the experimental groups didn\'t present statistically significant differences among the averages of volumes. In the radiographic evaluation of the final quality of thermoplasticized obturation, there are evidences that Obtura II technique produced endodontic obturation with qualities statistically inferior of the other techniques. In general, we can consider that Thermafil, Ultrafil 3D and Fused techniques presented similar results in relation to the volume of the extruded filling material and the final radiographic\'s quality of obturation, while Thermafil and Fused techniques exhibited more favorable results in relation to frequency of visual extrusion of gutta-percha and/or sealer.
6

Análise comparativa \'in vitro\' da extrusão apical de dentina produzida por diferentes técnicas de instrumentação manuais e rotatórias nos canais radiculares / Comparative analysis of dentin apical extrusion through different manual and rotary instrumentation root canal technique

Clarice Fernandes Eloy da Costa 16 April 2007 (has links)
No tratamento endodôntico nos deparamos com a necessidade de privar pelo bom estado pós-operatório do paciente. Dessa forma, devemos minimizar os efeitos que uma instrumentação pode causar sobre os tecidos periapicais. Nesse dilema, o presente estudo tem como objetivo comparar a quantidade de material sólido extruído além do forame apical através de duas técnicas de instrumentação manuais: técnica Step-Back ou Escalonada regressiva e técnica de Oregon e três técnicas de instrumentação mecânicorotatórias preconizadas pelos fabricantes dos instrumentos: Sistema ProTaper, Sistema K3 Endo e Sistema FKG RaCeTM. Setenta e cinco dentes unirradiculados foram utilizados, sendo 15 dentes para cada técnica. O material sólido extruído foi coletado por um filtro de papel (Whatman®). Tais filtros foram, após a instrumentação, submetidos a secagem em estufa e posterior pesagem em balança digital de alta precisão. A massa de resíduo extruído foi dada pela diferença entre a massa inicial e a massa final. A análise dos resultados mostrou extrusão de material sólido além do forame apical em todas as técnicas de instrumentação utilizadas, porém foi observado que a técnica Step-Back promoveu maior quantidade de material extruído quando comparada às outras técnicas e que não houve diferença significante entre as técnicas de Oregon e as dos Sistemas rotatórios. As técnicas foram assim classificadas em ordem crescente de material sólido extruído além do forame apical: Sistema K3 Endo, Sistema ProTaper, Sistema FKGRaCe, técnica de Oregon e Técnica Step Back. / Patient\'s general health is fundamental during endodontic therapy. Thus, we must minimize the harmful instrumentation effects in the periapical tissues. The aim of this study was to compare the amount of solid material extruded beyond the apical foramen among 2 manual instrumentation techniques: Step-Back and the Oregon\'s technique, as well as 3 mechanorotary techniques preconized by the manufacturers of the following instruments: ProTaper, K3 Endo, and FKG RaCeTM Systems. Seventy-five unirradicular teeth were used, being 15 teeth in each technique. The solid material extruded was collected with a paper filter (Whatman). Afterward, the filters were dry in the oven and weighted in an analytical balance. The extruded material was considered as the difference between final and initial mass values. Data analysis showed extrusion for all instrumentation techniques; however, the Step-back technique provided greater values than the other techniques, and no differences were seen among the Oregon and the rotary techniques. Progressive classification for the extruded material was the following: K3 Endo, ProTaper, FKGRaCe, Oregon, and The Step-back technique.
7

Comparação do transporte, centralização e extrusão apical de detritos após o uso de sistemas de NiTi em canais radiculares curvos

Boijink, Daiana January 2018 (has links)
Introdução: Os objetivos do presente estudo foram comparar a extrusão apical de detritos durante o preparo apical #25 com os sistemas Twisted File Adaptive (TFA), WaveOne Gold (WOG) e técnica manual (TM), registrar o tempo de preparo; e comparar WOG com TFA em relação ao transporte do canal radicular (TCR) e centralização (CR) com diâmetros apicais #25 e #35. Metodologia: Quarenta e cinco canais mésio-vestibulares de molares inferiores foram preparados e divididos em 3 grupos (n=15) para avaliar extrusão apical. A extrusão de detritos foi quantificada subtraindo-se o peso final do peso inicial dos tubos Eppendorf. TCR e CR foram avaliados em micro-TC com os sistemas TFA e WOG (n=15). A normalidade dos valores obtidos para cada grupo foi verificada usando teste de Kolmogorov-Smirnov. Para quantificar detritos extruídos e tempo de preparo, os dados foram paramétricos, sendo utilizado o Teste ANOVA de 1 via e post hoc de Tukey’s. Para avaliar TCR e CR, o teste estatístico foi Mann Whitney e Wilcoxon (α=.05). Resultados: Em relação aos detritos, o sistema WOG foi associado com menos extrusão em comparação com TM (P<0,05) ou com o sistema TFA (P> 0,05). O tempo de preparo exigido pela TM foi significativamente maior do que o exigido pelas outras técnicas (P<0,05). Não foram encontradas diferenças estatisticamente significantes entre WOG e TFA em relação à centralização em todos os níveis, quando usado diâmetro apical #25 ou #35 (P> 0,05). Para TCR, diferença significativa foi encontrada entre TFA e WOG a 1 e 7mm com diâmetro apical #25 e #35 (P<0,05). Foi encontrada diferença significante para TFA em 4mm, quando os diâmetros apicais #25 e #35 foram avaliados no mesmo sistema (P <0,05). Conclusões: Todos os sistemas de instrumentação causaram extrusão de detritos apicais em algum grau. TFA e WOG podem ser usados em canais radiculares curvos com segurança com diâmetros apicais# 25 ou 35. / Introduction: The aims of this study were to assess the amount of apically debris during root canal preparation with apical size #25 with the Twisted File Adaptive system (TFA), WaveOne Gold system (WOG) and manual technique (MT), and recorded working time; and to assess WOG with TFA in relation to root canal transportation (RCT) and centering ratio (CR) with apical diameters # 25 and # 35. Methods: Forty-five mesiobuccal root canals of mandibular molars were prepared and assigned into 3 groups (n = 15) to evaluate apical extrusion. Debris extrusion was quantified by subtracting the final from the initial weight of the Eppendorf tubes. RCT and CR were evaluated in Micro-TC with the TFA and WOG systems (n = 15). The normality values obtained for each group were tested using the Kolmogorov-Smirnov test. To quantify extruded debris and preparation time, the data were parametric, using the Tukey's 1-way and post-hoc ANOVA test. To evaluate RCT and CR, the statistical test was Mann Whitney (α =.05). Results: The WaveOne Gold reciprocating single-file system was associated with less extrusion of debris compared with hand files (P < 0.05) or with the Twisted File Adaptive system (P > 0.05). The preparation time required by hand files was significantly longer than that required by the other techniques (P < 0.05). No significant differences were found between WOG and TFA regarding CR for all levels when used #25 or #35 apical size preparation (p>0.05). For RCT, significant difference was found among TFA and WOG at 1 mm and 7 mm with diameter apical #25 and #35. (p<0.05). Statistically different for the TFA in 4 mm was observed when the apical diameters # 25 and # 35 was evaluated in the same system (P <0,05). Conclusions: All of the instrumentation systems caused apical debris extrusion to some degrees. TFA and WOG can be used in curved root canals with safety with #25 or 35 apical diameters.
8

Comparação do transporte, centralização e extrusão apical de detritos após o uso de sistemas de NiTi em canais radiculares curvos

Boijink, Daiana January 2018 (has links)
Introdução: Os objetivos do presente estudo foram comparar a extrusão apical de detritos durante o preparo apical #25 com os sistemas Twisted File Adaptive (TFA), WaveOne Gold (WOG) e técnica manual (TM), registrar o tempo de preparo; e comparar WOG com TFA em relação ao transporte do canal radicular (TCR) e centralização (CR) com diâmetros apicais #25 e #35. Metodologia: Quarenta e cinco canais mésio-vestibulares de molares inferiores foram preparados e divididos em 3 grupos (n=15) para avaliar extrusão apical. A extrusão de detritos foi quantificada subtraindo-se o peso final do peso inicial dos tubos Eppendorf. TCR e CR foram avaliados em micro-TC com os sistemas TFA e WOG (n=15). A normalidade dos valores obtidos para cada grupo foi verificada usando teste de Kolmogorov-Smirnov. Para quantificar detritos extruídos e tempo de preparo, os dados foram paramétricos, sendo utilizado o Teste ANOVA de 1 via e post hoc de Tukey’s. Para avaliar TCR e CR, o teste estatístico foi Mann Whitney e Wilcoxon (α=.05). Resultados: Em relação aos detritos, o sistema WOG foi associado com menos extrusão em comparação com TM (P<0,05) ou com o sistema TFA (P> 0,05). O tempo de preparo exigido pela TM foi significativamente maior do que o exigido pelas outras técnicas (P<0,05). Não foram encontradas diferenças estatisticamente significantes entre WOG e TFA em relação à centralização em todos os níveis, quando usado diâmetro apical #25 ou #35 (P> 0,05). Para TCR, diferença significativa foi encontrada entre TFA e WOG a 1 e 7mm com diâmetro apical #25 e #35 (P<0,05). Foi encontrada diferença significante para TFA em 4mm, quando os diâmetros apicais #25 e #35 foram avaliados no mesmo sistema (P <0,05). Conclusões: Todos os sistemas de instrumentação causaram extrusão de detritos apicais em algum grau. TFA e WOG podem ser usados em canais radiculares curvos com segurança com diâmetros apicais# 25 ou 35. / Introduction: The aims of this study were to assess the amount of apically debris during root canal preparation with apical size #25 with the Twisted File Adaptive system (TFA), WaveOne Gold system (WOG) and manual technique (MT), and recorded working time; and to assess WOG with TFA in relation to root canal transportation (RCT) and centering ratio (CR) with apical diameters # 25 and # 35. Methods: Forty-five mesiobuccal root canals of mandibular molars were prepared and assigned into 3 groups (n = 15) to evaluate apical extrusion. Debris extrusion was quantified by subtracting the final from the initial weight of the Eppendorf tubes. RCT and CR were evaluated in Micro-TC with the TFA and WOG systems (n = 15). The normality values obtained for each group were tested using the Kolmogorov-Smirnov test. To quantify extruded debris and preparation time, the data were parametric, using the Tukey's 1-way and post-hoc ANOVA test. To evaluate RCT and CR, the statistical test was Mann Whitney (α =.05). Results: The WaveOne Gold reciprocating single-file system was associated with less extrusion of debris compared with hand files (P < 0.05) or with the Twisted File Adaptive system (P > 0.05). The preparation time required by hand files was significantly longer than that required by the other techniques (P < 0.05). No significant differences were found between WOG and TFA regarding CR for all levels when used #25 or #35 apical size preparation (p>0.05). For RCT, significant difference was found among TFA and WOG at 1 mm and 7 mm with diameter apical #25 and #35. (p<0.05). Statistically different for the TFA in 4 mm was observed when the apical diameters # 25 and # 35 was evaluated in the same system (P <0,05). Conclusions: All of the instrumentation systems caused apical debris extrusion to some degrees. TFA and WOG can be used in curved root canals with safety with #25 or 35 apical diameters.
9

Avaliação quantitativa e qualitativa da extrusão apical em técnicas de obturação termoplastificada. / Quantitative and qualitative evaluation of the apical extrusion in techniques of thermoplasticized obturation.

Fábio Strefezza 29 March 2004 (has links)
Atualmente, as técnicas de obturação com guta-percha termoplastificada têm mostrado eficiência na adaptação dos materiais obturadores às paredes do sistema de canais radiculares, promovendo um selamento tridimensional. Porém, com a utilização destas técnicas, há dificuldade no controle longitudinal durante a obturação, que poderia acarretar em extrusão do material obturador em direção aos tecidos perirradiculares, influenciando na reparação pós tratamento endodôntico. Assim, o propósito deste estudo foi avaliar in vitro a extrusão apical de quatro técnicas de obturação termoplastificada, Thermafil, Obtura II, Ultrafil 3D e Fusionada, através de uma nova metodologia de mensuração de volume do material obturador extruído, relacionando com a freqüência da extrusão visual de guta-percha e/ou cimento e a qualidade radiográfica final da obturação. Os resultados demonstraram que a metodologia do sistema de mensuração foi efetiva para quantificar o volume de material obturador extruído, constatando extrusão em todas as técnicas termoplastificadas empregadas neste estudo, porém, quantitativamente, os grupos experimentais não apresentaram diferenças estatisticamente significantes entre as médias de volumes. Na avaliação radiográfica da qualidade final das obturações termoplastificadas, há evidências de que a técnica Obtura II produziu obturações endodônticas com qualidades estatisticamente inferiores às demais técnicas. De modo geral, podemos considerar que as técnicas Thermafil, Ultrafil 3D e Fusionada apresentaram resultados semelhantes em relação ao volume do material obturador extruído e qualidade radiográfica final da obturação, enquanto que as técnicas Thermafil e Fusionada exibiram resultados mais favoráveis em relação à freqüência da extrusão visual de guta-percha e/ou cimento. / In the present, the obturation techniques with termoplasticized gutta-percha have been proving efficiency in adaptation of the filling material to the walls of the root canal system, promoting a three-dimensional sealing. Even so, with the use of these techniques, there is difficulty in the longitudinal control during the obturation, that could cause the extrusion of the filling material in direction to the perirradicular tissues, influencing the healing after endodontic treatment. Thus, the purpose of this study was to evaluate in vitro the apical extrusion of four thermoplasticized obturation techniques, Thermafil, Obtura II, Ultrafil 3D and Fused, with a new methodology of volume?s measurement of the extruded filling material, relating with the frequency of the visual extrusion of gutta-percha and/or sealer and the final radiographic\'s quality of obturation. The results demonstrated that the methodology of the measurement system was effective to quantify the volume of the extruded filling material, verifying extrusion in all the thermoplasticized techniques studied, even so, quantitatively, the experimental groups didn\'t present statistically significant differences among the averages of volumes. In the radiographic evaluation of the final quality of thermoplasticized obturation, there are evidences that Obtura II technique produced endodontic obturation with qualities statistically inferior of the other techniques. In general, we can consider that Thermafil, Ultrafil 3D and Fused techniques presented similar results in relation to the volume of the extruded filling material and the final radiographic\'s quality of obturation, while Thermafil and Fused techniques exhibited more favorable results in relation to frequency of visual extrusion of gutta-percha and/or sealer.
10

Calcium sparks enhance the tissue fluidity within epithelial layers and promote apical extrusion of transformed cells / カルシウムスパークは上皮層での組織流動性を亢進し、変異細胞の管腔側への逸脱を促進する

Kuromiya, Keisuke 23 March 2023 (has links)
京都大学 / 新制・課程博士 / 博士(医科学) / 甲第24533号 / 医科博第147号 / 新制||医科||10(附属図書館) / 京都大学大学院医学研究科医科学専攻 / (主査)教授 篠原 隆司, 教授 松田 道行, 教授 伊藤 貴浩 / 学位規則第4条第1項該当 / Doctor of Medical Science / Kyoto University / DFAM

Page generated in 0.1136 seconds