• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 4
  • 3
  • Tagged with
  • 23
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Rotatory power of optically active benzoic esters containing ionisable ortho-substituents

Hill, John M. January 1931 (has links)
Among the many and varied fields of present day chemistry, that of optical activity occupies a not unimportant position. The rotatory powers of the alkali and ammonium salts of d-sec-βoctyl hydrogen phthalate have been studied in alcoholic and aqueous solution. The rotations of the salts were found to be in the order H > Li > NH4 > Na > K > Rb. It has been concluded that the variation of the molecular rotation of the salts with concentration may be explained by assuming changes in the degree of dissociation of the electrolytes and a deforming influence of the cations on the optically active anions. The effect of the addition of inorganic salts of various valence types to 0.2 M aqueous solutions of d-sec-β-octyl sodium phthalate has been investigated. The series for the depressive influence of the alkali and ammonium chlorides on the rotatory power of the optically active electrolyte is Cs+> Rb+> K+> Na+> NH4+> Li+. The corresponding series for the divalent chlorides is Ba++> Sr++> Ca++> Mg++. It is concluded that the observed effects may be attributed mainly to a deforming influence of the positive ion on the optically active negative ion, the explanation involving a consideration of the ionic radii. It is worthy of comment that the above results have been obtained by use of a carboxylic acid containing no hydroxyl group.
2

The synthesis and resolution of 1-Fluoro-12-Methylbenzo(C)Phenanthrene /

Mentzer, Robert George January 1962 (has links)
No description available.
3

Application of RL in control systems using the example of a rotatory inverted pendulum

Wittig, M., Rütters, R., Bragard, M. 13 February 2024 (has links)
In this paper, the use of reinforcement learning (RL) in control systems is investigated using a rotatory inverted pendulum as an example. The control behavior of an RL controller is compared to that of traditional LQR and MPC controllers. This is done by evaluating their behavior under optimal conditions, their disturbance behavior, their robustness and their development process. All the investigated controllers are developed using MATLAB and the Simulink simulation environment and later deployed to a real pendulum model powered by a Raspberry Pi. The RL algorithm used is Proximal Policy Optimization (PPO). The LQR controller exhibits an easy development process, an average to good control behavior and average to good robustness. A linear MPC controller could show excellent results under optimal operating conditions. However, when subjected to disturbances or deviations from the equilibrium point, it showed poor performance and sometimes instable behavior. Employing a nonlinear MPC Controller in real time was not possible due to the high computational effort involved. The RL controller exhibits by far the most versatile and robust control behavior. When operated in the simulation environment, it achieved a high control accuracy. When employed in the real system, however, it only shows average accuracy and a significantly greater performance loss compared to the simulation than the traditional controllers. With MATLAB, it is not yet possible to directly post-train the RL controller on the Raspberry Pi, which is an obstacle to the practical application of RL in a prototyping or teaching setting. Nevertheless, RL in general proves to be a flexible and powerful control method, which is well suited for complex or nonlinear systems where traditional controllers struggle.
4

Avaliação microbiológica e quantificação de raspas extruídas por instrumentos reciprocantes e rotatórios com variação no calibre e na irrigação ultrassônica passiva / Microbiological evaluation and quantification of extruded debris by reciprocating and rotating instruments with variation in caliber and passive ultrasonic irrigation

Cardenas Cuellar, Maricel Rosario 28 March 2018 (has links)
Foi objetivo deste estudo, avaliar comparativamente o volume dos debris e a extrusão bacteriana apical durante o preparo de canais radiculares com os instrumentos Prodesign R e Prodesign Logic, com diferentes calibres e presença de irrigação ultrassônica passiva (PUI) ou não, em dentes contaminados com Enterococcus faecalis (ATCC29212). Métodos: Foram empregados 90 pré-molares inferiores, decoronados e padronizados em 16 mm, divididos em 8 grupos (n=10) segundo os sistemas a serem empregados; Prodesign Logic 25.06, 35.05, Prodesign R 25.06 e 35.05, e o tipo de ativação do irrigante, contaminados durante 5 dias. Debris extruídos foram coletados em microtubos vazios pesados previamente 3 vezes, inseridos na parte inferior de um dispositivo metálico para uma posterior pesagem dos debris. Também foram realizadas coletas dos canais e dos debris extruídos para uma avaliação microbiológica através da contagem das unidades formadoras de colônias (UFC/mL). Resultados: O tipo de movimento rotatório e reciprocante e o diâmetro do calibre, 25 ou 35, não mostraram diferenças entre si (P>0.05). Comparando a irrigação convencional com o emprego do ultrassom, este último promoveu uma maior quantidade de debris extruídos pelo forame (P<0.05). Na análise microbiológica das coletas dos debris, o sistema Prodesign Logic 25 promoveu uma maior quantidade de raspas contaminadas (P<0.05). Nas coletas dos canais tanto a irrigação convencional quanto o uso do ultrassom mostraram uma diminuição das UFC/mL das coletas iniciais comparadas com as finais, sem diferença estatística (P<0.05). A contaminação microbiana nas raspas extruídas foi menor no grupo onde foi empregada a irrigação convencional (P<0.05). Conclusões: Os calibres dos instrumentos e o tipo de movimento utilizado nos canais radiculares agiram de forma semelhante, diminuindo a contaminação do canal principal e extruindo a mesma quantidade de debris, com a mesma contaminação. A PUI aumentou a extrusão e a contaminação dos debris dentinários em comparação com a irrigação convencional. / The main of this study was to compare the volume of debris and apical bacterial extrusion during root canal preparation with the Prodesign R and Prodesign Logic instruments, with different calibers and presence of passive ultrasonic irrigation (PUI) or not, in teeth contaminated with Enterococcus faecalis (ATCC29212). Methods: 90 lower premolars were used, decoronated and standardized in 16 mm, divided into 8 groups (n = 10) according to the systems to be used; Prodesign Logic 25.06, 35.05, Prodesign R 25.06 and 35.05, and the type of irrigant activation, contaminated for 5 days. Extruded debris were collected in empty microtubes previously weighed 3 times, inserted in the inferior part of a metallic device for a later weighing of the debris. Samples of main root canals were also collected in addition of debris for a microbiological evaluation of colony forming units (CFU / mL). Results: The movement, rotational or reciprocating, and the diameter of the caliber, 25 or 35, showed no differences between them (P> 0.05). Comparing conventional irrigation with the use of ultrasound, the latter promoted a greater amount of debris extruded through the foramen (P <0.05). In the microbiological analysis of the debris collections, the Prodesign Logic 25 system promoted a greater amount of contaminated debris (P <0.05). I In the collections of the root canal both the conventional irrigation and the ultrasonic agitation showed a decrease of the CFU / mL from initial collections compared to the finals, with no statistical difference (P <0.05). Microbial contamination in the extruded debris was lower in the group where conventional irrigation was used (P <0.05). Conclusions: The instrument, caliber and the type of movement used in root canals acted similarly, reducing the contamination of the main root canal and extruding the same amount of debris, with the same contamination. PUI increased the extrusion and contamination of dentinal debris compared to conventional irrigation.
5

\"Resistência à perda de corte de instrumentos rotatórios de níquel-titânio submetidos à implantação iônica de nitrogênio\" / utting ability resistance in nickel-titanium instruments submitted to nitrogen ion implantation

Costa, Cristiane da 05 December 2006 (has links)
O presente estudo verificou o aumento da resistência à perda de corte de instrumentos produzidos em liga de níquel-titânio, após tratamento de implantação iônica de nitrogênio. Para tal, foram utilizados vinte e um instrumentos da marca K3 ?ENDO, de n° 25.02, com 21 mm, divididos em dois grupos. O grupo 1 foi constituído por onze instrumentos submetidos à ação de uma câmara de implantação iônica de nitrogênio, servindo um deles como controle para a determinação da quantidade de íons implantados. O grupo 2 foi composto por dez instrumentos não submetidos ao processo de implantação iônica. Cada lima instrumentou 20 blocos de canais simulados 20.02 de 21 mm, previamente lavados em cuba ultra-sônica com detergente a 40°C por 10 minutos e depois com água bidestilada por mais 10 minutos. Os mesmos foram secos com jato de ar, voltaram para estufa a 40°C por 2 dias e finalmente pesados em balança analítica. Após cada instrumentação os blocos foram lavados em cuba ultra-sônica com detergente a 40°C por 20 minutos e pesados novamente. O ensaio de resistência à perda de corte foi realizado mediante a instrumentação de cada bloco com auxílio de um simulador de ação da instrumentação endodôntica, sendo a amplitude percorrida pelo contra-ângulo padronizada em 2,5 mm a cada penetração por 8 vezes atingindo um total de 2,0 cm para dentro do canal simulado, com força de penetração de 1,5 N. Quanto a resistência à perda de corte os resultados mostraram que os instrumentos implantados não apresentaram diferença estatisticamente significante em nível de 5 % (? = 0,5 %) até 20 usos. Porém, os instrumentos não implantados mostraram diferença estatisticamente significante (? = 0,5 %) entre 5 e 15 usos, 5 e 20 usos, bem como entre 10 e 20 usos. Ao compararem-se instrumentos implantados e não implantados, observou-se que em 5 e 10 usos não houve diferença estatisticamente significante (p>5%). Já na comparação entre ambos com 15 e 20 usos a diferença foi estatisticamente significante (? = 0,5 %). Lícito foi concluir, portanto, que o processo de implantação de íons de nitrogênio manteve a resistência à perda de corte de instrumentos produzidos em liga de níquel-titânio até 20 usos. Os instrumentos não implantados mostraram perda progressiva do poder de corte significativamente entre 5 e 15 usos, 5 e 20 usos, bem como entre 10 e 20 usos. Comparando-se instrumentos implantados e não implantados, observou-se que até 10 usos ambos comportaram-se igualmente no que respeita à perda de corte. Já na comparação entre ambos com 15 e 20 usos a diferença foi significativa. / The present study investigated the cutting ability resistance in nickel-titanium instruments after nitrogen ion implantation treatment. Twenty-one instruments of K3 ?ENDO brand, number 20.02, with 21 mm, were divided in two groups. The group 1 submitted 11 instruments to nitrogen ion implantation chamber, while on served as positive control for the determination of the ion implantation quantity. In group 2, the 10 instruments were not submitted to ion implantation treatment. Each file instrumented 20 acrylic blocks 20.02 with 21 mm, previously washed in ultrasonic container with detergent in 40°C for 10 minutes and then with bidestiled water for 10 minutes. They were dried and put in a 40°C stove for 2 days and finally weighed in analytic balance. After instrumentation the blocks were washed for 20 minutes and weighed again. The usage essay was realized through the instrumentation of each block using an endodontic instrumentation simulated action, with a 2,5 mm standardized distance for 8 times, getting a total of 2,0 cm inside the simulated canal with a strong penetration of 1,5 N. The results showed that there was no statistical difference in cutting resistance of instruments treated with ionic implantation process until 20 uses. Although in the non treated instruments there was a gradual reduce in cutting ability resistance from 5 to 20 uses. The conclusion was that the nitrogen ion implantation process increases the cutting resistance of nickel-titanium instruments.
6

Avaliação da desinfecção do canal radicular frente ao preparo químico-cirúrgico por meio rotatório associado ou não a tratamento químico complementar / Assessment of the disinfection of root canals using a rotatory system associated or not to a complementary chemical treatment

Santana, Soraia Veloso Silva 09 April 2008 (has links)
A desinfecção dos canais radiculares figura como constante preocupação clínica. Esta pesquisa teve a proposta de verificar o nível de desinfecção alcançado pela instrumentação mecanizada utilizando o sistema K3 em relação ao uso desse mesmo sistema associado a um tratamento químico dentinário complementar. Foram utilizados 16 caninos inferiores unirradiculares, que foram aleatoriamente divididos em dois grupos. Foram realizados 2 ensaios em dias diferentes, cada ensaio formado por 8 dentes em cada grupo. As coroas dos dentes foram cortadas e o tamanho das raízes padronizado em 15 mm. Os canais foram esvaziados com auxilio de limas tipo K de números 10 ou 15 com hipoclorito de sódio a 1% seguido de 20 mL de tiosulfato de sódio a 5%. Seguiu-se então a odontometria. Os dentes foram impermeabilizados externamente por duas camadas de cianoacrilato de etila e montados em tubos Eppendorf a expensas de adesivo epóxico. Os conjuntos (raiz + Eppendorf) foram esterilizados em autoclave por 20 min a 134 °C. Os espécimes foram inoculados com uma da suspensão correspondente à concentração bacteriana 0,5 da escala de Mc Farland (1,5 x 108 UFC). A primeira coleta microbiológica foi realizada imediatamente após o tempo de incubação para estabelecer o número de unidades formadoras de colônias. O preparo químicocirúrgico dos canais radiculares do grupo 1 foi realizado apenas por meio do sistema rotatório K3. Cones de papel absorvente esterilizados foram inseridos no canal radicular para nova coleta. Os dentes do Grupo 2 também tiveram os canais radiculares preparados com sistema rotatório K3 até a fase de irrigação-aspiração final com hipoclorito de sódio a 0,5% e EDTA-T a 17%. Após essa etapa foi realizado o tratamento químico da dentina que correspondeu à inserção de solução de hipoclorito de sódio a 1% no interior da cavidade pulpar e com uma lima tipo K de número 25 a solução foi agitada durante um minuto. Esse procedimento foi repetido 5 vezes num total de 10 mL dessa substância e somando um tempo de 10 minutos. A irrigação final foi efetuada com 10 mL de solução de hipoclorito de sódio a 0,5% seguidas de 20 mL de solução de EDTA- T a 17% (pH 7,0). Nova coleta para exame microbiológico foi realizada. Essas suspensões sofreram diluições seriadas de 10-1 a 10-7 em água peptonada antes do preparo químico-cirúrgico e de10-1 a 10-5 após o mesmo As diluições foram então semeadas em triplicata em placas contendo TSA. Após o período de 24 h de incubação as placas que apresentaram crescimento bacteriano tiveram o número de unidades formadoras de colônias (UFCs) determinado. Embora houvesse redução da população bacteriana em ambos os grupos no que se refere ao pré e pós-operatório, os resultados demonstraram que não houve diferença estatística significante entre os grupos de estudo (p>0,05). / The effective disinfection of root canals represents a constant clinical concern. This research aimed at verifying the level of disinfection achieved by mechanical instrumentation using the K3 system when compared to the associated use of the same system and a complementary chemical dentinal treatment. Sixteen singlerooted lower canines were randomly divided into two groups. Two experiments, each using 8 teeth per group, were conducted on different days. The dental crowns were sectioned and the root length was standardized to 15 mm. The canals were instrumented using #10 or 15 K-files with 1% sodium hypochlorite, followed by 5% sodium thiosulfate. The root canals were measured. The teeth were made externally impermeable by two layers of ethyl cyanoacrylate and placed in Eppendorf tubes using epoxy resin. The compounds (root + Eppendorf) were sterilized in an autoclave for 20 min at 134oC. A suspension that corresponds to the bacterial concentration of 0.5 on the McFarland scale (1.5 x 108 CFU) was inoculated onto the specimens. The first microbiological sample collection was done immediately after incubation in order to determine the number of colony-forming units. Chemical preparation of the root canals of group 1 was done using the K3 rotatory system exclusively. Sterile paper cones were inserted into the canal for a new collection. Teeth from group 2 also had their root canals prepared using the K3 rotatory system up to the phase of final irrigation with 0.5% sodium hypochlorite and 17% EDTA-T. Next, chemical dentinal treatment was done by inserting a 1% sodium hypochlorite solution into the pulp cavity and agitating for one minute with the aid of a #25 K-file. This step was repeated 5 times using a total of 10 ml of the solution for a total duration of 10 minutes. Final irrigation was done using 10 ml of 0.5% sodium hypochlorite solution followed by 20 ml of 17% EDTA-T (pH 7.0). A new collection for microbiological examination was done. These suspensions underwent serial dilutions from 10-1 to 10- 7 using peptone water before preparation and from 10-1 to 10-5 afterwards. The dilutions were then inoculated thrice onto TSA plates. After an incubation period of 24h, the number of colony-forming units (CFU) was determined for the plates which presented with bacterial growth. Although there was a reduction of the bacterial population in both experimental groups when pre and post-operative counts were compared, results demonstrated that there was no statistically significant difference between the two study groups (p>0.05).
7

Espectropolarimetro computadorizado : nova maneira de obtenção da atividade ótica / Computerized spectrometer: a new way to obtain optical activity data

Melo, Washington Luiz de Barros 23 May 1985 (has links)
Montamos um espectrômetro o qual nos permite obter dados de atividade ótica Dispersão Rotatória (DRO) e Dicroísmo Circular (DC) simultaneamente. O sistema ótico consiste de uma fonte de luz, um monocromador, um suporte para amostra, um analisador gigante e um detector de luz. O analisador girante é sustentado por um mancal pneumático e gira usando um motor de passo, o qual é controlado por um microcomputador. Um outro motor de passo também controlado por microcomputador é usado para girar a grade de difração do monocromador. Para obter os espectros de DRO e DC, o monocromador pára em um certo comprimento de onda, enquanto o eixo de transmissão do analisador é posicionado em &#946= 0&#176, 45&#176, 90&#176 e -45&#176 relativo ao eixo de transmissão do polarizador. O microcomputador através do detector de luz lê as quatro intensidades de luz e usando um formalismo desenvolvido por nós, relaciona-as à elipticidade e a rotação ótica naquele comprimento de onda. O monocromador é então girado a um novo comprimento de onda e o procedimento é repetido. No final, os espectros de DC e DRO podem ser mostrados em uma Tabela ou com um Gráfico. Além de funcionar como um espectropolarímetro, o equipamento pode ser usado também como um espectrofotômetro, para acompanhar cinética de reação, para medir dicroísmo linear, etc... Devido à relação sinal/ruído, temos nos ângulos medidos, uma resolução de 1&#186 / We have assembled a spectrometer which provides the optical activity data Optical Rotatory Dispersion (ORD) and Circular Dichroism (CD) simultaneously. The Optical System consists of a source of light, a monochromator, a polarizer, a sample holder, a rotating analyzer and a light detector. The rotating analyzer is supported by a pneumatic bearing and rotates using a step motor which is controlled by a microcomputer. Another spet motor also controlled by the microcomputer is used to rotate the diffraction grating of the monochromator. To obtain the ORD and CD spectra, the monochromator stops at a certain wave length, while the transmission axis of the analyzer is positioned at &#946= 0&#176, 45&#176, 90&#176 e -45&#176 relative to the transmission axis of the polarizer. The microcomputer through the light detector reads the four light intensities and using the formalism developed by us relates them to the elipticity and optical rotation at that wavelength. The monochromator is then rotated to a new wavelength and the procedure is repeated. At the end the CD and ORD spectra can be shown in a Table or as a graph. Besides functioning as a spectropolarimeter, the equipment can be use also as a regular spectrometer, to follow kinetic of recreations, to measure linear dichroism, etc Due to the signal/noise ratio we have in the measured angles a resolution of 1&#176
8

Espectropolarimetro computadorizado : nova maneira de obtenção da atividade ótica / Computerized spectrometer: a new way to obtain optical activity data

Washington Luiz de Barros Melo 23 May 1985 (has links)
Montamos um espectrômetro o qual nos permite obter dados de atividade ótica Dispersão Rotatória (DRO) e Dicroísmo Circular (DC) simultaneamente. O sistema ótico consiste de uma fonte de luz, um monocromador, um suporte para amostra, um analisador gigante e um detector de luz. O analisador girante é sustentado por um mancal pneumático e gira usando um motor de passo, o qual é controlado por um microcomputador. Um outro motor de passo também controlado por microcomputador é usado para girar a grade de difração do monocromador. Para obter os espectros de DRO e DC, o monocromador pára em um certo comprimento de onda, enquanto o eixo de transmissão do analisador é posicionado em &#946= 0&#176, 45&#176, 90&#176 e -45&#176 relativo ao eixo de transmissão do polarizador. O microcomputador através do detector de luz lê as quatro intensidades de luz e usando um formalismo desenvolvido por nós, relaciona-as à elipticidade e a rotação ótica naquele comprimento de onda. O monocromador é então girado a um novo comprimento de onda e o procedimento é repetido. No final, os espectros de DC e DRO podem ser mostrados em uma Tabela ou com um Gráfico. Além de funcionar como um espectropolarímetro, o equipamento pode ser usado também como um espectrofotômetro, para acompanhar cinética de reação, para medir dicroísmo linear, etc... Devido à relação sinal/ruído, temos nos ângulos medidos, uma resolução de 1&#186 / We have assembled a spectrometer which provides the optical activity data Optical Rotatory Dispersion (ORD) and Circular Dichroism (CD) simultaneously. The Optical System consists of a source of light, a monochromator, a polarizer, a sample holder, a rotating analyzer and a light detector. The rotating analyzer is supported by a pneumatic bearing and rotates using a step motor which is controlled by a microcomputer. Another spet motor also controlled by the microcomputer is used to rotate the diffraction grating of the monochromator. To obtain the ORD and CD spectra, the monochromator stops at a certain wave length, while the transmission axis of the analyzer is positioned at &#946= 0&#176, 45&#176, 90&#176 e -45&#176 relative to the transmission axis of the polarizer. The microcomputer through the light detector reads the four light intensities and using the formalism developed by us relates them to the elipticity and optical rotation at that wavelength. The monochromator is then rotated to a new wavelength and the procedure is repeated. At the end the CD and ORD spectra can be shown in a Table or as a graph. Besides functioning as a spectropolarimeter, the equipment can be use also as a regular spectrometer, to follow kinetic of recreations, to measure linear dichroism, etc Due to the signal/noise ratio we have in the measured angles a resolution of 1&#176
9

Avaliação da desinfecção do canal radicular frente ao preparo químico-cirúrgico por meio rotatório associado ou não a tratamento químico complementar / Assessment of the disinfection of root canals using a rotatory system associated or not to a complementary chemical treatment

Soraia Veloso Silva Santana 09 April 2008 (has links)
A desinfecção dos canais radiculares figura como constante preocupação clínica. Esta pesquisa teve a proposta de verificar o nível de desinfecção alcançado pela instrumentação mecanizada utilizando o sistema K3 em relação ao uso desse mesmo sistema associado a um tratamento químico dentinário complementar. Foram utilizados 16 caninos inferiores unirradiculares, que foram aleatoriamente divididos em dois grupos. Foram realizados 2 ensaios em dias diferentes, cada ensaio formado por 8 dentes em cada grupo. As coroas dos dentes foram cortadas e o tamanho das raízes padronizado em 15 mm. Os canais foram esvaziados com auxilio de limas tipo K de números 10 ou 15 com hipoclorito de sódio a 1% seguido de 20 mL de tiosulfato de sódio a 5%. Seguiu-se então a odontometria. Os dentes foram impermeabilizados externamente por duas camadas de cianoacrilato de etila e montados em tubos Eppendorf a expensas de adesivo epóxico. Os conjuntos (raiz + Eppendorf) foram esterilizados em autoclave por 20 min a 134 °C. Os espécimes foram inoculados com uma da suspensão correspondente à concentração bacteriana 0,5 da escala de Mc Farland (1,5 x 108 UFC). A primeira coleta microbiológica foi realizada imediatamente após o tempo de incubação para estabelecer o número de unidades formadoras de colônias. O preparo químicocirúrgico dos canais radiculares do grupo 1 foi realizado apenas por meio do sistema rotatório K3. Cones de papel absorvente esterilizados foram inseridos no canal radicular para nova coleta. Os dentes do Grupo 2 também tiveram os canais radiculares preparados com sistema rotatório K3 até a fase de irrigação-aspiração final com hipoclorito de sódio a 0,5% e EDTA-T a 17%. Após essa etapa foi realizado o tratamento químico da dentina que correspondeu à inserção de solução de hipoclorito de sódio a 1% no interior da cavidade pulpar e com uma lima tipo K de número 25 a solução foi agitada durante um minuto. Esse procedimento foi repetido 5 vezes num total de 10 mL dessa substância e somando um tempo de 10 minutos. A irrigação final foi efetuada com 10 mL de solução de hipoclorito de sódio a 0,5% seguidas de 20 mL de solução de EDTA- T a 17% (pH 7,0). Nova coleta para exame microbiológico foi realizada. Essas suspensões sofreram diluições seriadas de 10-1 a 10-7 em água peptonada antes do preparo químico-cirúrgico e de10-1 a 10-5 após o mesmo As diluições foram então semeadas em triplicata em placas contendo TSA. Após o período de 24 h de incubação as placas que apresentaram crescimento bacteriano tiveram o número de unidades formadoras de colônias (UFCs) determinado. Embora houvesse redução da população bacteriana em ambos os grupos no que se refere ao pré e pós-operatório, os resultados demonstraram que não houve diferença estatística significante entre os grupos de estudo (p>0,05). / The effective disinfection of root canals represents a constant clinical concern. This research aimed at verifying the level of disinfection achieved by mechanical instrumentation using the K3 system when compared to the associated use of the same system and a complementary chemical dentinal treatment. Sixteen singlerooted lower canines were randomly divided into two groups. Two experiments, each using 8 teeth per group, were conducted on different days. The dental crowns were sectioned and the root length was standardized to 15 mm. The canals were instrumented using #10 or 15 K-files with 1% sodium hypochlorite, followed by 5% sodium thiosulfate. The root canals were measured. The teeth were made externally impermeable by two layers of ethyl cyanoacrylate and placed in Eppendorf tubes using epoxy resin. The compounds (root + Eppendorf) were sterilized in an autoclave for 20 min at 134oC. A suspension that corresponds to the bacterial concentration of 0.5 on the McFarland scale (1.5 x 108 CFU) was inoculated onto the specimens. The first microbiological sample collection was done immediately after incubation in order to determine the number of colony-forming units. Chemical preparation of the root canals of group 1 was done using the K3 rotatory system exclusively. Sterile paper cones were inserted into the canal for a new collection. Teeth from group 2 also had their root canals prepared using the K3 rotatory system up to the phase of final irrigation with 0.5% sodium hypochlorite and 17% EDTA-T. Next, chemical dentinal treatment was done by inserting a 1% sodium hypochlorite solution into the pulp cavity and agitating for one minute with the aid of a #25 K-file. This step was repeated 5 times using a total of 10 ml of the solution for a total duration of 10 minutes. Final irrigation was done using 10 ml of 0.5% sodium hypochlorite solution followed by 20 ml of 17% EDTA-T (pH 7.0). A new collection for microbiological examination was done. These suspensions underwent serial dilutions from 10-1 to 10- 7 using peptone water before preparation and from 10-1 to 10-5 afterwards. The dilutions were then inoculated thrice onto TSA plates. After an incubation period of 24h, the number of colony-forming units (CFU) was determined for the plates which presented with bacterial growth. Although there was a reduction of the bacterial population in both experimental groups when pre and post-operative counts were compared, results demonstrated that there was no statistically significant difference between the two study groups (p>0.05).
10

\"Resistência à perda de corte de instrumentos rotatórios de níquel-titânio submetidos à implantação iônica de nitrogênio\" / utting ability resistance in nickel-titanium instruments submitted to nitrogen ion implantation

Cristiane da Costa 05 December 2006 (has links)
O presente estudo verificou o aumento da resistência à perda de corte de instrumentos produzidos em liga de níquel-titânio, após tratamento de implantação iônica de nitrogênio. Para tal, foram utilizados vinte e um instrumentos da marca K3 ?ENDO, de n° 25.02, com 21 mm, divididos em dois grupos. O grupo 1 foi constituído por onze instrumentos submetidos à ação de uma câmara de implantação iônica de nitrogênio, servindo um deles como controle para a determinação da quantidade de íons implantados. O grupo 2 foi composto por dez instrumentos não submetidos ao processo de implantação iônica. Cada lima instrumentou 20 blocos de canais simulados 20.02 de 21 mm, previamente lavados em cuba ultra-sônica com detergente a 40°C por 10 minutos e depois com água bidestilada por mais 10 minutos. Os mesmos foram secos com jato de ar, voltaram para estufa a 40°C por 2 dias e finalmente pesados em balança analítica. Após cada instrumentação os blocos foram lavados em cuba ultra-sônica com detergente a 40°C por 20 minutos e pesados novamente. O ensaio de resistência à perda de corte foi realizado mediante a instrumentação de cada bloco com auxílio de um simulador de ação da instrumentação endodôntica, sendo a amplitude percorrida pelo contra-ângulo padronizada em 2,5 mm a cada penetração por 8 vezes atingindo um total de 2,0 cm para dentro do canal simulado, com força de penetração de 1,5 N. Quanto a resistência à perda de corte os resultados mostraram que os instrumentos implantados não apresentaram diferença estatisticamente significante em nível de 5 % (? = 0,5 %) até 20 usos. Porém, os instrumentos não implantados mostraram diferença estatisticamente significante (? = 0,5 %) entre 5 e 15 usos, 5 e 20 usos, bem como entre 10 e 20 usos. Ao compararem-se instrumentos implantados e não implantados, observou-se que em 5 e 10 usos não houve diferença estatisticamente significante (p>5%). Já na comparação entre ambos com 15 e 20 usos a diferença foi estatisticamente significante (? = 0,5 %). Lícito foi concluir, portanto, que o processo de implantação de íons de nitrogênio manteve a resistência à perda de corte de instrumentos produzidos em liga de níquel-titânio até 20 usos. Os instrumentos não implantados mostraram perda progressiva do poder de corte significativamente entre 5 e 15 usos, 5 e 20 usos, bem como entre 10 e 20 usos. Comparando-se instrumentos implantados e não implantados, observou-se que até 10 usos ambos comportaram-se igualmente no que respeita à perda de corte. Já na comparação entre ambos com 15 e 20 usos a diferença foi significativa. / The present study investigated the cutting ability resistance in nickel-titanium instruments after nitrogen ion implantation treatment. Twenty-one instruments of K3 ?ENDO brand, number 20.02, with 21 mm, were divided in two groups. The group 1 submitted 11 instruments to nitrogen ion implantation chamber, while on served as positive control for the determination of the ion implantation quantity. In group 2, the 10 instruments were not submitted to ion implantation treatment. Each file instrumented 20 acrylic blocks 20.02 with 21 mm, previously washed in ultrasonic container with detergent in 40°C for 10 minutes and then with bidestiled water for 10 minutes. They were dried and put in a 40°C stove for 2 days and finally weighed in analytic balance. After instrumentation the blocks were washed for 20 minutes and weighed again. The usage essay was realized through the instrumentation of each block using an endodontic instrumentation simulated action, with a 2,5 mm standardized distance for 8 times, getting a total of 2,0 cm inside the simulated canal with a strong penetration of 1,5 N. The results showed that there was no statistical difference in cutting resistance of instruments treated with ionic implantation process until 20 uses. Although in the non treated instruments there was a gradual reduce in cutting ability resistance from 5 to 20 uses. The conclusion was that the nitrogen ion implantation process increases the cutting resistance of nickel-titanium instruments.

Page generated in 0.035 seconds