Spelling suggestions: "subject:"aquecimento condutiva"" "subject:"aquecimento condutividade""
1 |
Determinação e avaliação da bioacessibilidade de minerais em amostras de linhaça e gergelim por espectrometria de emissão óptica com plasma indutivamente acopladoSouza, Laís Araújo 04 February 2015 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-05-04T14:00:31Z
No. of bitstreams: 1
Dissertação-Lais-versãofinal-CORREÇÃOFINAL_2.pdf: 3528248 bytes, checksum: 58df0e2fdafc44c1c2d36ef8cde8b6ee (MD5) / Approved for entry into archive by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-05-12T18:05:12Z (GMT) No. of bitstreams: 1
Dissertação-Lais-versãofinal-CORREÇÃOFINAL_2.pdf: 3528248 bytes, checksum: 58df0e2fdafc44c1c2d36ef8cde8b6ee (MD5) / Made available in DSpace on 2016-05-12T18:05:13Z (GMT). No. of bitstreams: 1
Dissertação-Lais-versãofinal-CORREÇÃOFINAL_2.pdf: 3528248 bytes, checksum: 58df0e2fdafc44c1c2d36ef8cde8b6ee (MD5) / CAPES,CNPq e FAPESB / A linhaça (Linum usitatissimum L.) e o gergelim (Sesamum indicum L.) são alimentos funcio-
nais amplamente consumidos pela população e prescritos por nutricionistas devido às quantidades
recomendadas desses elementos ingeridos nas dietas que deve suprir alguma necessidade do indiví-
duo. O objetivo deste trabalho foi propor estratégias analíticas para determinação de micronutrientes
em amostras de linhaça e gergelim, empregando diferentes procedimentos de preparo de amostras e
determinação por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES).
As amostras linhaça (marrom e dourada) e gergelim (branco, cru e preto) foram adquiridas em esta-
belecimentos comerciais da cidade de Salvador, BA e Rio de Janeiro, RJ e os elementos determina-
dos foram Ca, Cu, Fe, K, Mg, Mn, P e Zn. As condições otimizadas para o procedimento proposto,
empregando aquecimento condutivo em bloco digestor, foram: cerca de 500 mg de amostra, 5,0 mL
de HNO3 destilado, 1,0 mL de H2SO4, 3,0 mL de H2O2, temperatura máxima de 250°C e tempo total
de 2h. A eficiência do procedimento de decomposição das amostras foi avaliada a partir dos baixos
teores de carbono residual (< 2% m m-1) e acidez residual (1,11 mol L-1). A exatidão do método foi
verificada com material de referência certificado de farinha de soja (NIST 3234), apresentando per-
centuais de recuperação dos elementos de 89 a 113%. O método proposto apresentou boa precisão
(RSD < 10%) e baixos limites de detecção (0,0001 a 0,22 mg L-1). As faixas de concentração, em µg
g-1, para os analitos nas amostras de linhaça foram: Ca (1533 - 3163), Cu (10,6 - 21,6), Fe (36,5 -
86,8), K (6636 - 10238), Mg (2093 - 3024), Mn (18,5 - 49,4), P (6102 - 11771) e Zn (19,8 - 59,8) e nas
amostras de gergelim foram: Ca (570 - 9501), Cu (13,3 - 19,4), Fe (41,3 - 114,8), K (4570 - 6209), Mg
(2287 - 3145), Mn (9,0 - 28,6), P (4767 - 11364) e Zn (46,0 - 88,3). Ferramentas estatísticas como a
análise de componente principal (PCA) e análise de agrupamento hierárquico (HCA) foram aplicadas
e foi observada uma tendência de similaridade entre as amostras com uma pequena dispersão entres
as variedades estudadas. Os teores dos micronutrientes para a maioria das amostras estão concor-
dantes com os valores da Tabela de Composição de Alimentos (TACO). Para avaliar a bioacessibili-
dade foram realizados procedimentos de extração utilizando o método in vitro SBET (Simple Bioac-
cessibility Extraction Test). As faixas de bioacessibilidade, em %, para os analitos nas amostras de
linhaça foram: Ca (50 - 123), Cu (34 - 78), Fe (21 - 64), K (40 - 83), Mg (66 - 118), Mn (24 - 94), P (31
- 83) e Zn (46 - 116) e para as amostras de gergelim foram: Ca (36 - 115) ,Cu (20 - 108), Fe (16 - 87),
K(63 - 119), Mg (64 - 126), Mn (32 - 105), P (24 - 73) e Zn (47 - 108). Os resultados obtidos neste
trabalho trazem informações inéditas sobre a composição em termos de micronutrientes e bioacessi-
bilidade para as amostras de linhaça e gergelim, contribuindo, assim, para a tabela de composição
mineral dos alimentos. / Linseed (Linum usitatissimum L.) and sesame (Sesamum indicum L.) are functional foods
widely consumed by humans and prescribed by nutritionists. Also, those elements are important be-
cause they are required to maintain human body homeostasis. This study aiming to development of
analytical strategies to quantifying micronutrients in flaxseed and sesame samples applying differ-
ent sample preparation procedures and inductively coupled plasma optical emission spectrometry
(ICP OES) for the measurements. The linseed samples (brown and gold) and sesame (white, raw and
black) were purchased in commercial establishments in Salvador (Bahia) and Rio de Janeiro (Rio de
Janeiro) cities. Moreover, Ca, Cu, Fe, K, Mg, Mn, P and Zn were determined. The optimized condi-
tions for the proposed procedure, employing conductive heating by digester block, were: samples
mass of 500 mg, 5.0 mL of distilled HNO3, 1.0 mL of H2SO4, 3.0 mL of H2O2 and maximum heating
temperature equal to 250 °C during 2 hours. The decomposition procedure efficiency of that sample
was evaluated from residual low carbon content (< 2% m m-1) and residual acidity (1.11 mol L-1). The
method accuracy was verified with soy flour certified reference material (NIST 3234) showing recovery
percents of elements from 89 to 113%. The proposed method showed good precision (RSD <10%)
and low detection limits (from 0.0001 to 0.22 mg L-1). The concentration ranges in µg g-1 for the ana-
lytes in linseed and sesame samples were: Ca (1533 to 3163), Cu (10.6 to 21.6), Fe (36.5 to 86.8),
K (6636 to 10238), Mg (2093 to 3024), Mn (18.5 to 49.4), P (6102 to 11771) and Zn (19.8 to 59.8);
and Ca (570 to 9501), Cu (13.3 to 19.4), Fe (41.3 to 114.8), K (4570 to 6209), Mg (2287 to 3145),
Mn (9.0 to 28.6 ), P (4767 to11364) and Zn (46.0 to 88.3), respectively. Statistical methods such
as Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) were applied and
was observed a similarity tendency between samples with a small dispersion among the stu-
died varieties. The micronutrients content in samples was in agreement with those shown in TACO
(Brazilian food composition table). To evaluate the bioaccessibility extraction procedures were per-
formed using the in vitro method SBET (Simple Bioaccessibility Extraction Test). The analytes bioac-
cessibility ranges (%) in linseed and sesame samples were: Ca (50 to 123), Cu (34 to 78) Fe (21
to 64) K (40 to 83), Mg (66 to 118 ), Mn (24 to 94), P (31 to 83), Zn (46 to 116); and Ca (36 to 115),
Cu (20 to 108), Fe (16 to 87) , K (63 to 119), Mg (64 to 126), Mn (32 to 105), P (24 to 73), Zn (47 to
108), respectively. Finally, these results obtained in this work bring new information about the compo-
sition in terms of micronutrients and bioaccessibility for linseed and sesame samples, therefore contri-
buting to feed mineral composition tables.
|
2 |
Aperfeiçoamento e avaliação de um novo sistema de digestão assistida por aquecimento condutivo em frasco fechado para preparar amostras de carne “in natura” para análise elementar / Improvement and evaluation of a new closed-vessel conductively heated digestion system to prepare fresh meat samples for elemental analysisVieira, Alan Lima [UNESP] 04 March 2016 (has links)
Submitted by ALAN LIMA VIEIRA null (alan.vieira@hotmail.com) on 2016-03-23T00:12:16Z
No. of bitstreams: 1
Dissertação ALAN LIMA VIEIRA.pdf: 3306402 bytes, checksum: bb2ced7b7ded44be46ee02b3cbf5db60 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-03-23T13:36:36Z (GMT) No. of bitstreams: 1
vieira_al_me_araiq.pdf: 3306402 bytes, checksum: bb2ced7b7ded44be46ee02b3cbf5db60 (MD5) / Made available in DSpace on 2016-03-23T13:36:36Z (GMT). No. of bitstreams: 1
vieira_al_me_araiq.pdf: 3306402 bytes, checksum: bb2ced7b7ded44be46ee02b3cbf5db60 (MD5)
Previous issue date: 2016-03-04 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Estabelecer procedimentos simples, rápidos, eficientes e com preparo de amostras de baixo custo para determinar elementos em amostras de carne é um aspecto relevante para fins nutricionais e de saúde. Por esta razão, um sistema de digestão com aquecimento condutivo em frasco fechado (CHDS), foi avaliado recentemente para a decomposição de amostras “in natura” de músculo, fígado e rim (bovino, suíno e frango) visando a determinação de macronutrientes (Ca, Mg, Na, K, S e P), micronutrientes (Cu, Fe, Mn, Mo, Se e Zn) e contaminantes inorgânicos (As, Cd, Cr e Pb) por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES) e espectrometria de massas com plasma acoplado indutivamente (ICP-MS). O aperfeiçoamento feito no CHDS foi planejado para melhorar a segurança, a praticidade e a robustez do sistema. Entre elas destaca-se a adaptação de um pistão a gás na tampa do gabinete de digestão; isolamento dos frascos no interior do gabinete de digestão; tampa de Teflon com sistema simples de alívio de pressão ao fim da decomposição sem manuseio do frasco. A precisão foi avaliada analisando três materiais de referência certificados digeridos pelo CHDS. As recuperações para Ca, Cu, Fe, Mg, Mn, Na, K, S, P e Zn determinados por ICP OES, variaram entre 85 a 106%. Para As, Cd, Cr, Mo, Pb e Se determinados por ICP-MS, foram obtidas recuperações entre 92 a 110%. A eficiência da digestão também foi avaliada pela determinação do teor de carbono residual, que variou de 10 a 12% m m-1. Quando as amostras de carne foram digeridas usando o CHDS, os resultados para Ca, Cu, Fe, Mg, Mn, Na, K, S, P e Zn determinados por ICP OES e para As, Cd, Cr, Mo, Pb e Se determinados por ICP-MS foram concordantes com aqueles obtidos após digestão ácida assistida por radiação micro-ondas em frasco fechado (MW-AD). Ao utilizar o CHDS, os limites de quantificação foram similares aos obtidos com a MW-AD para todos os analitos. O CHDS é capaz de digerir 800 mg de amostra de carne “in natura” utilizando 2 mL de HNO3 e 1 mL H2O2. O procedimento proposto foi capaz de atender a Instrução Normativa da Secretária de Defesa Agropecuária (SDA) nº 13 que trata do monitoramento de resíduos e contaminantes em carnes para As, Cd e Pb. Os resultados obtidos neste estudo estendem as aplicações do CHDS para amostras com maior teor de gordura, tais como músculo, fígado e rim. Este sistema de digestão simples e de baixo custo pode ser utilizado para preparar amostras para determinação subsequente de um grande número de elementos por espectrometria de ICP, incluindo espécies voláteis, tais como, As, Cd e Se. / Establishing simple, fast, efficient and low-cost sample preparation procedures to determine elements in meat samples is a relevant aspect for nutritional and health purposes. For this reason, the recently proposed closed-vessel conductivelyheated digestion system (CHDS) was evaluated for the decomposition of muscle, liver and kidney (cattle, pigs and chickens) samples fresh aiming for the determination of macronutrients (Ca, Mg, Na, K, S and P), micronutrients (Cu, Fe, Mn, Mo, Se and Zn) and inorganic contaminants (As, Cd, Cr and Pb) by inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS). The optimization of the CHDS was planned to improve safety, practicality and robustness such as adaptation of a gas piston in the digestion cabinet cover, isolation of vessels inside the digestion cabinet and a Teflon cap with a simple pressure relief system in the end of the decomposition without handling the vessel. The accuracy was evaluated by analyzing three certified reference materials digested by the CHDS. Recoveries for Ca, Cu, Fe, Mg, Mn, Na, K, S, P and Zn determinations by ICP OES varied from 85 to 106%. For As, Cd, Cr, Mo, Pb and Se determinations by ICP-MS, recoveries within the 92-110% were obtained. The digestion efficiency was also evaluated by determining the residual carbon content, which varied from 10 to 12% m m-1. When fresh meat samples were digested using the CHDS, results for Ca, Cu, Fe, Mg, Mn, Na, K, S, P and Zn determinations by ICP OES and for As, Cd, Cr, Mo, Pb and Se determinations by ICP-MS were in agreement with those obtained after closed-vessel microwave-acid digestion (MW-AD). When using the CHDS, limits of quantification were similar to those obtained with the MW-AD for all analytes. The CHDS enabled the digestion of 800 mg of fresh meat with 2 mL of HNO3 and 1 ml of H2O2. The proposed procedure was able to attend the normative instruction of agricultural defense secretary SDA N°. 13 for As, Cd and Pb. The results obtained in this study extend the applications of the CHDS to samples with higher contents of fat such as muscle, liver and kidney. This simple and low-cost digestion system can be used to prepare samples for subsequent determination of a large number of elements by ICP spectrometry, including volatile species such as As, Cd and Se.
|
Page generated in 0.0962 seconds