131

Desempenho de sistemas de condicionamento de ar com utilização de energia solar em edifícios de escritórios. / Performance of solar air conditioning systems in office buildings.

Ara, Paulo José Schiavon 14 December 2010 (has links)
A preocupação energética tem impulsionado a humanidade a buscar alternativas sustentáveis de energia. Neste contexto, os edifícios de escritórios têm um papel importante, em especial, devido ao elevado consumo de energia dos sistemas de condicionamento de ar. Para esses sistemas, a possibilidade de utilização de energia solar é uma alternativa tecnicamente possível e interessante de ser considerada, principalmente porque, quando a carga térmica do edifício é mais elevada, a radiação solar também é mais elevada. Dentre os sistemas de condicionamento de ar solar, o sistema térmico - que associa coletores solares térmicos com chiller de absorção - é o mais disseminado, na atualidade. Entretanto, dependendo do caso, outras tecnologias podem ser vantajosas. Uma opção, por exemplo, no caso de edifícios de escritórios, é o sistema elétrico - que associa painéis fotovoltaicos ao chiller convencional de compressão de vapor. Neste trabalho, para um edifício de escritórios de 20 pavimentos e 1000 m2 por pavimento, na cidade de São Paulo, no Brasil, duas alternativas de ar condicionado solar tiveram seus desempenhos energéticos analisados: o sistema térmico - com coletores solares térmicos somente na cobertura e o sistema elétrico - com painéis FV somente nas superfícies opacas das fachadas. Para isso, com o software EnergyPlus do Departamento de Energia dos Estados Unidos obteve-se as carga térmica atuantes no edifício e com a aplicação do método de cálculo de consumo de energia dos sistemas de ar condicionado solar, proposto pelo Projeto SOLAIR da União Européia, adaptado para a realidade da pesquisa, obteve-se o desempenho energético dos sistemas. Os resultados mostraram que, para o edifício de 20 pavimentos, o sistema elétrico tem o melhor desempenho energético, economizando 28% e 71% da energia elétrica que consumiria um sistema de ar condicionado convencional, em um dia de verão e de inverno, respectivamente. O sistema térmico, ao contrário, apresentou um desempenho energético ruim para o edifício estudado, consumindo, por exemplo, em um dia de verão, cerca de 4 vezes mais energia elétrica do que um sistema de ar condicionado convencional. Constatouse que isso ocorreu, pois a área coletora limitada à cobertura foi insuficiente para atender a demanda do chiller de absorção, que passou a operar com frações solares baixas, da ordem de 50% e 20%, de pico, no dia de inverno e de verão, respectivamente. Assim, constatou-se que para que o sistema térmico apresente um desempenho energético satisfatório é preciso que o edifício não seja tão alto. De fato, os resultados mostraram que somente se o edifício tivesse no máximo 2 pavimentos, o sistema térmico teria um desempenho energético melhor do que um sistema convencional. No caso de ser aplicado ao edifício térreo de 1000m2 de área, por exemplo, esse sistema economizaria aproximadamente 65% da energia elétrica do sistema convencional. Por fim, constatou-se também que o desempenho energético do sistema térmico seria elevado com a otimização da área e da tecnologia de coletores solares, com o aprimoramento do sistema de aquecimento auxiliar e com a redução da carga térmica do edifício por meio de técnicas passivas de climatização. / Energy concern has driven human kind to seek sustainable energy alternatives. In this context, office buildings have an important role, especially due to the high energy consumption of air conditioning systems. For these systems, the possibility of using solar energy is technically feasible and interesting to be considered, mainly because generally when the building thermal load is higher, the solar radiation is also higher. Among solar airconditioning systems, the thermal system - which combines solar collectors with absorption chiller - is the most widespread, nowadays. However, depending on the case, other technologies may take advantage. One option, for example, in the case of office buildings, is the electrical system - which combines photovoltaic panels with conventional vapor compression chiller. In this work, an office building of 20 floors with 1,000 m2 floor area, in Sao Paulo, Brazil, two technologies of solar air conditioning had their performance analyzed: the thermal system - presenting solar thermal collectors only on the roof and the electrical system with PV panels only on the opaque surfaces of the facades. For this, the software EnergyPlus of the United States Department of Energy obtained the building thermal load and the with the solar air conditioning energy consumption calculating method proposed by SOLAIR project of the European Union and adapted to this work, energy performance of systems was obtained. The results showed that for this building, the electrical system had the best energy performance, saving 28% and 71% of electricity that would consume a conventional air conditioning system in a summer day and a winter day, respectively. The thermal system, in contrast, showed a poor energy performance, consuming, for example, on a summer day, about four times more electricity than a conventional air conditioning system. It was found that this occurred because the collectors area limited to the roof of the building was insufficient to meet the absorption chiller demand, causing low solar fractions in the operation, of around 50% and 20% peak, in a winter day and in a summer day, respectively. Thus, in order of provide a satisfactory energy performance, the thermal system requires that the building not to be so tall. In fact, the results showed that only if the building had up to two floors, the system would perform better than a conventional system. In case of be installed in a building with the ground floor only, and floor area of 1000m2, for example, this system would save about 65% of the electricity comparing to a conventional system. Finally, it was found that this energy performance would be elevated as well with the optimization of solar collectors area and technology, with auxiliary heating system improvement and with the reduction of thermal load of the building by means of passive air conditioning techniques.
132

Conforto térmico e eficiência energética em hotéis econômicos / Thermal comfort and energy efficiency in Budget Hotels

Anarrita Bueno Buoro 17 March 2008 (has links)
Este trabalho busca avaliar a eficiência energética e o conforto, em ambiente climatizado artificialmente, dos Hotéis Econômicos de redes internacionais em São Paulo. A avaliação levada a cabo concentrou-se nas unidades habitacionais (UH) desses hotéis, principal produto oferecido por eles, possuidoras de sistema de ar condicionado (SAC), apesar das condições climáticas e das características do uso não determinarem essa necessidade. Com base nos levantamentos sobre as características dos Hotéis Econômicos, foi escolhido um hotel de uma rede internacional em São Paulo como estudo de caso. Nele, avaliou-se o desempenho térmico por meio de medições de temperatura e umidade relativa do ar em duas UH, durante cinco dias. As características físicas desse hotel foram utilizadas como modelo-base para as simulações computacionais realizadas no software TAS NG (2005). A partir dos resultados obtidos nas medições, definiram-se os critérios que seriam utilizados nas variações do modelo paramétrico, resultando em um total de sete cenários, com diferentes características como: vidros, cortina interna, taxa de ventilação e período determinado para ventilação. Levando-se em conta as condições climáticas da cidade de São Paulo e as características físicas e ocupacionais dos apartamentos, verificou-se que é possível obter conforto térmico sem o uso de SAC. Nessas condições, utilizou-se como critério de avaliação o modelo adaptativo da Norma ASHRAE 55 (2004). Os dados dos dias mais representativos de verão e inverno forma utilizados na análise dos ganhos de calor. Foi também avaliado, para o período de um ano, o consumo de energia elétrica do SAC, para resfriamento e aquecimento. Os resultados obtidos auxiliaram na proposição de recomendações de projeto para essa tipologia, buscando soluções que aprimoram o aproveitamento das condições naturais favoráveis para a obtenção de conforto térmico, possibilitando a redução do consumo de energia decorrente do SAC nestes ambientes. Para ilustrar algumas recomendações foram feitos estudos preliminares para as UH e para o pavimento tipo, considerando a integração do SAC com soluções de projeto de arquitetura que favoreçam o melhor desempenho energético de Hotéis Econômicos ou de qualquer categoria. / This work aims to evaluate the energy efficiency and comfort level, in airconditioned environments of budget hotels, from international chains, in São Paulo, Brazil. The evaluation was directed to the apartments which are the hotels main product featuring air conditioning, even though the climate conditions and usage profile dont determine its need. One hotel from an international chain was chosen as a case study based on research of budget hotels main features. The hotel had its thermal performance evaluated through air temperature and humidity measurements, in two apartments, for five days. Its physical characteristics were inputted into the TAS NG (2005) software as a base model for simulations. The measurements results defined the criteria used in the parametric model, resulting in a total of seven scenarios with different characteristics such as glass, internal shades, ventilating rates and period. Considering São Paulos climatic conditions, the physical and occupational characteristics of the apartments, it was verified that it is possible to reach thermal comfort without the use of air conditioning. The evaluating criterion used in these conditions was an adaptive model from the ASHRAE 55 (2004) Norm. Data from the most representative days of summer and winter were used in the analysis. There was also an evaluation of the energy consumption of the air condition- ing system, used for cooling and heating purposes, for a period of one year. The results favored the proposal for project recommendations for this typology, seeking solutions to improve the capacity to harness the favorable natural conditions to obtain thermal comfort, allowing for energy consumption reduction due to air conditioning. To illustrate the recommendations some preliminary studies were prepared for the apartments and pavement type, considering the integration of the air conditioning system with architectural design solutions that favor a better energy performance of budget hotels or of any other category.
133

Impacto econômico do uso de ar condicionado em edifícios residenciais na cidade de Maceió/AL. / Economical impact of the use of air conditionine systems in residential buildines in the city of Maceió/AL.

Leão Júnior, Ricardo Sérgio Neves 03 June 2008 (has links)
The waste energy is a very important factor that affects environmental crisis in the world. Buildings have been consuming nearly 40% global energy production, and the building industry has been identified as a sector where substantial savings may occur. In residential buildings, the energy consumption is strongly related to air conditioning systems. In Maceio, the use of passive strategies as natural ventilation seems irrelevant by construction sector. This case results in well, fair, bad or very bad residential apartments in relation to climatic conditions. The apartments located in west quadrant have smaller price than apartments located in east quadrant. It is an attractive factor to the consumer purchase apartments badly adapted to climate. This situation contributes with wild use of air conditioning systems. The use of these equipments results in costs of purchase, operation and maintenance. Not always the accounting oh these values are properly considered in the moment of apartment s acquisition. Facing this context, the present work intends to evaluate the economical impact of air conditioning systems use in residential apartments in Maceio city, Brazil. Emphasize the link between waste energy and financial costs in long term involving this question. By case study, be adopted one methodology that analyze: apartment s energy performance in some variable using the EnergyPlus software; natural ventilation performance in some orientation, by qualitative analysis in water table models; economic analysis based on monthly consumption of energy for different situations simulated, accomplish comparison between energy costs for air conditioning system use and the price of apartments. The analysis have shown the energy costs in long term for all situations simulated represent large portion of integral apartment s value. When the monthly cost is applied in savings account, most situations pay total value of apartments. In all cases, this investment overcome the economy make possible in acquisition of west apartment invest in same circumstances. Results lead to the conclusion that the use of passive strategies of thermal comfort is a very good economics strategy for the consumer, and the purchase of badly adapted apartments is very expensive, above all when be considered the economical impacts for air conditioning systems use in long term. / Fundação de Amparo a Pesquisa do Estado de Alagoas / O desperdício energético é um dos fatores de maior impacto sobre o desequilíbrio ambiental enfrentado pelo planeta. As edificações respondem pelo consumo de aproximadamente 40% da energia gerada no planeta, sendo o setor da construção civil identificado como uma área de grande potencial para combater o desperdício energético. Nas edificações residenciais, o consumo energético está fortemente relacionado aos sistemas mecânicos de controle térmico como os sistemas de ar condicionado, por exemplo. Em Maceió, o Mercado Imobiliário parece não buscar soluções arquitetônicas que se aprofundem no uso de estratégias passivas de conforto térmico, como a ventilação natural, por exemplo. Na referida cidade, é identificada a existência de apartamentos residenciais bem, razoavelmente, mal ou pessimamente orientados frente aos condicionantes climáticos. Os apartamentos voltados para o quadrante oeste (posição poente) possuem preço menor que aqueles voltados para o quadrante leste (posição nascente), sendo esse um atrativo para o consumidor adquirir apartamentos mal adaptados ao clima. Essa situação contribui com o uso desenfreado de aparelhos de ar condicionado. O uso destes equipamentos acarreta em custos de aquisição, operação e manutenção dos mesmos. No entanto, a contabilização destes valores nem sempre é devidamente considerada no momento da aquisição dos bens imóveis. Diante desse contexto, o presente trabalho avalia o impacto econômico decorrente da utilização de aparelhos de ar condicionado em apartamentos residenciais de 02 quartos na cidade de Maceió/AL. Busca enfatizar o elo existente entre o desperdício de energia e o custo financeiro em longo prazo envolvido neste processo. Através de um estudo de caso, adotou-se uma metodologia na qual foram analisados: o desempenho energético dos apartamentos sob diferentes variáveis, utilizando o software EnergyPlus; o comportamento da ventilação natural nos apartamentos de acordo com as diferentes orientações geográficas, através de análises qualitativas utilizando maquetes em Mesa D água; análises econômicas baseadas no consumo médio mensal de energia para as diferentes situações simuladas, realizando comparações entre o custo energético para utilização de ar condicionado e o preço de mercado dos apartamentos. Os resultados demonstraram que os custos energéticos em longo prazo de todas as situações simuladas representam uma grande parcela do valor total do imóvel. Quando o custo mensal é aplicado em caderneta de poupança, a maioria das situações paga, com sobras, o valor total do imóvel. A economia possibilitada pela aquisição do apartamento poente aplicada em caderneta de poupança durante longo prazo é superada, em todos os casos, pela aplicação em iguais condições do custo energético mensal para uso de ar condicionado. Desta forma, conclui-se que a utilização de estratégias passivas de controle térmico representa um grande meio de economia para o consumidor, e que a compra de apartamentos mal adaptados ao clima é extremamente dispendiosa, sobretudo quando considerado o impacto econômico derivado do uso de ar condicionado em longo prazo.
134

Modelo de mensuração de mercado para bens duráveis: o caso de condicionadores de ar para uso residencial

Flores, Dalva Regina 24 March 1997 (has links)
Made available in DSpace on 2010-04-20T20:08:22Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-03-24T00:00:00Z / It discusses a model to measure durable goods market by cities. The modeling process assumes that the function must be established by analyzing the stage of the product i n the diffusion process, each city i s a unit represented by secondary data, and the secondary data are determined by knowing the characteristics of the consumer behavior o f the product In the model the residuals are presented as strategic marketing tools. I t is exposed an application to air conditioning market. / Trata de uma proposta de mensuração de mercado de bens duráveis em nível municipal. O processo de modelagem assume que: a função deve ser determinada a partir do análise do estágio do produto em seu processo de difusão n o mercado, cada município é uma unidade representada p o r variáveis obtidas através d e dados secundários e os dados secundários a serem coletados podem determinados através d o conhecimento d o comportamento de compra do produto. No modelo, os resíduos sã o tratados como ferramenta estratégica mercadológica. É apresentada uma aplicação do modelo para condicionadores de ar
135

Desempenho de sistemas de condicionamento de ar com utilização de energia solar em edifícios de escritórios. / Performance of solar air conditioning systems in office buildings.

Paulo José Schiavon Ara 14 December 2010 (has links)
A preocupação energética tem impulsionado a humanidade a buscar alternativas sustentáveis de energia. Neste contexto, os edifícios de escritórios têm um papel importante, em especial, devido ao elevado consumo de energia dos sistemas de condicionamento de ar. Para esses sistemas, a possibilidade de utilização de energia solar é uma alternativa tecnicamente possível e interessante de ser considerada, principalmente porque, quando a carga térmica do edifício é mais elevada, a radiação solar também é mais elevada. Dentre os sistemas de condicionamento de ar solar, o sistema térmico - que associa coletores solares térmicos com chiller de absorção - é o mais disseminado, na atualidade. Entretanto, dependendo do caso, outras tecnologias podem ser vantajosas. Uma opção, por exemplo, no caso de edifícios de escritórios, é o sistema elétrico - que associa painéis fotovoltaicos ao chiller convencional de compressão de vapor. Neste trabalho, para um edifício de escritórios de 20 pavimentos e 1000 m2 por pavimento, na cidade de São Paulo, no Brasil, duas alternativas de ar condicionado solar tiveram seus desempenhos energéticos analisados: o sistema térmico - com coletores solares térmicos somente na cobertura e o sistema elétrico - com painéis FV somente nas superfícies opacas das fachadas. Para isso, com o software EnergyPlus do Departamento de Energia dos Estados Unidos obteve-se as carga térmica atuantes no edifício e com a aplicação do método de cálculo de consumo de energia dos sistemas de ar condicionado solar, proposto pelo Projeto SOLAIR da União Européia, adaptado para a realidade da pesquisa, obteve-se o desempenho energético dos sistemas. Os resultados mostraram que, para o edifício de 20 pavimentos, o sistema elétrico tem o melhor desempenho energético, economizando 28% e 71% da energia elétrica que consumiria um sistema de ar condicionado convencional, em um dia de verão e de inverno, respectivamente. O sistema térmico, ao contrário, apresentou um desempenho energético ruim para o edifício estudado, consumindo, por exemplo, em um dia de verão, cerca de 4 vezes mais energia elétrica do que um sistema de ar condicionado convencional. Constatouse que isso ocorreu, pois a área coletora limitada à cobertura foi insuficiente para atender a demanda do chiller de absorção, que passou a operar com frações solares baixas, da ordem de 50% e 20%, de pico, no dia de inverno e de verão, respectivamente. Assim, constatou-se que para que o sistema térmico apresente um desempenho energético satisfatório é preciso que o edifício não seja tão alto. De fato, os resultados mostraram que somente se o edifício tivesse no máximo 2 pavimentos, o sistema térmico teria um desempenho energético melhor do que um sistema convencional. No caso de ser aplicado ao edifício térreo de 1000m2 de área, por exemplo, esse sistema economizaria aproximadamente 65% da energia elétrica do sistema convencional. Por fim, constatou-se também que o desempenho energético do sistema térmico seria elevado com a otimização da área e da tecnologia de coletores solares, com o aprimoramento do sistema de aquecimento auxiliar e com a redução da carga térmica do edifício por meio de técnicas passivas de climatização. / Energy concern has driven human kind to seek sustainable energy alternatives. In this context, office buildings have an important role, especially due to the high energy consumption of air conditioning systems. For these systems, the possibility of using solar energy is technically feasible and interesting to be considered, mainly because generally when the building thermal load is higher, the solar radiation is also higher. Among solar airconditioning systems, the thermal system - which combines solar collectors with absorption chiller - is the most widespread, nowadays. However, depending on the case, other technologies may take advantage. One option, for example, in the case of office buildings, is the electrical system - which combines photovoltaic panels with conventional vapor compression chiller. In this work, an office building of 20 floors with 1,000 m2 floor area, in Sao Paulo, Brazil, two technologies of solar air conditioning had their performance analyzed: the thermal system - presenting solar thermal collectors only on the roof and the electrical system with PV panels only on the opaque surfaces of the facades. For this, the software EnergyPlus of the United States Department of Energy obtained the building thermal load and the with the solar air conditioning energy consumption calculating method proposed by SOLAIR project of the European Union and adapted to this work, energy performance of systems was obtained. The results showed that for this building, the electrical system had the best energy performance, saving 28% and 71% of electricity that would consume a conventional air conditioning system in a summer day and a winter day, respectively. The thermal system, in contrast, showed a poor energy performance, consuming, for example, on a summer day, about four times more electricity than a conventional air conditioning system. It was found that this occurred because the collectors area limited to the roof of the building was insufficient to meet the absorption chiller demand, causing low solar fractions in the operation, of around 50% and 20% peak, in a winter day and in a summer day, respectively. Thus, in order of provide a satisfactory energy performance, the thermal system requires that the building not to be so tall. In fact, the results showed that only if the building had up to two floors, the system would perform better than a conventional system. In case of be installed in a building with the ground floor only, and floor area of 1000m2, for example, this system would save about 65% of the electricity comparing to a conventional system. Finally, it was found that this energy performance would be elevated as well with the optimization of solar collectors area and technology, with auxiliary heating system improvement and with the reduction of thermal load of the building by means of passive air conditioning techniques.