Spelling suggestions: "subject:"arma dde foco"" "subject:"arma dee foco""
1 |
Um caso de feridas do recto por arma de fogoHorta, Urgel Abílio January 1921 (has links)
No description available.
|
2 |
Estudo prospectivo dos ferimentos colicos por arma de fogo tratados por reparo primario ou colostomia segundo a sistematização de condutas proposta por HaddadBorghesi, Ronaldo Antonio 30 May 1995 (has links)
Orientador: Raul Raposo de Medeiros / Tese (doutorado) - Universidade Estadual Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-20T15:19:24Z (GMT). No. of bitstreams: 1
Borghesi_RonaldoAntonio_D.pdf: 4527312 bytes, checksum: ef71e129830b6af51779afedd98f3fd3 (MD5)
Previous issue date: 1995 / Resumo: Realizou-se um estado prospectivo para verificar a aplicabilidade da sistematização de condutas de HADDAD no tratamento das lesões do cólon. Selecionaram-se 127 pacientes portadores de lesão eólica penetrante por arma de fogo que sobreviveram a partir de 48 horas após a operação. Empregaram-se medidas padrões de atendimento inicial, ressuscitação por infusão de soros, antibióticos de largo espectro e tratamento apropriado para todas as lesões viscerais, sendo que para o cólon seguiram-se as normas previamente estabelecidas e influenciadas pelos fatores de risco. No seguimento dos casos, verificou-se o surgimento de complicações sépticas relacionadas à lesão eólica inicial. A maioria dos pacientes compreendeu homens adultos, jovens e brancos com ferimentos por tiros de revólver. Indicou-se o reparo primário, segundo critérios seletivos, em 97 casos, dos quais a sutura primária foi aplicada em 91 casos (71,7%), estando a maioria sem choque, com pequena contaminação peritoneal, com lesão eólica grau II, no máximo com um órgão associado lesado e com índice de trauma abdominal menor ou igual a 25. Para alguns desses casos, considerou-se de uma forma mais liberal a atuação dos fatores de risco, empregando-se a sutura primária menos seletivamente. Este foi o procedimento que apresentou menor índice de complicações e melhor evolução clínica. A hemicolectomia direita com anastomose primária, praticada em seis casos (4,7%) na presença de choque, maior contaminação peritoneal, maior severidade da lesão do cólon e índice de trauma abdominal maior do que 25 apresentou maior proporção de abscesso intraperitoneal do que a sutura primária. Executou-se a colostomia em 30 casos (23,6%) mais graves, com maior proporção de choque, contaminação peritoneal, número de vísceras lesadas e contagem do índice de trauma abdominal. Por esta razão, a freqüência de complicações sépticas, a permanência hospitalar e a mortalidade foram maiores quando comparadas ao reparo primário. A análise dos resultados obtidos permitiu a observação de que as táticas cirúrgicas adotadas orientaram adequadamente o tratamento das lesões do cólon. / Abstract: A prospective study was carried out to verify the applicability of HADDAD's systematization of procedures in the treatment of colon injuries. One hundred and twenty-seven carrier patients of full-thickness penetrating colic injury by firearms who have survived more than 48 hours after the operation, were selected. Initial care standard measures, resuscitation by fluids infusion, broad-spectrum antibiotics and proper treatment for all visceral lesions were performed, regarding the colon, the previously established and influenced by the risk factors rules have been followed. Throughout patients' follow up, the appearance of septic complications related to the initial colic lesion were examined. The majority of the patients included young adult whitemen undergoing revolver shot wounds. The primary repair was proposed according to selective criterious in 97 cases, of which the primary suture was performed in 91 cases (71,7%), being the majority with no shock, with minor peritoneal contamination, with grade II colic lesion, with at the utmost one associated organ injury and with an abdominal trauma index equal to or less than 25. For some of these cases, a more liberal way of the risk factors actuation was judged, making use of the primary suture less selectively. This procedure was the one which showed less complication rates and better clinical evolution. The right hemicolectomy with primary anastomosis, for being performed in six cases (4,7%) in the presence of shock, major peritoneal contamination, major severity of colon injury and an abdominal trauma index higher than 25, exhibited an intraperitoneal abscess ratio larger than the primary suture. The colostomy was performed in the 30 more serious cases (23,6%), with a higher proportion of shock, peritoneal contamination, number of injured visceras and abdominal trauma index score. For this reason, the septic complication rates, the hospital stay and the mortality rate were higher when compared to primary repair. Analysis of the obtained results allowed an observation that the adopted surgical tactics have guided properly the treatment of colon injuries. / Doutorado / Doutor em Cirurgia
|
3 |
Caracterização dos resíduos de disparo e das alterações em fibras de tecidos atingidos por tiros de arma de fogo com microscopia eletrônica de varredura e espectrometria de raios X característicosFrank, Paulo Ricardo Ost January 2016 (has links)
Tendo em vista o alto índice de criminalidade com armas de fogo no Brasil, é imperativo que a perícia forense tenha mais subsídios sobre resíduos de tiro e alterações provocadas por tiros em têxteis comumente encontrados em cenas de crime. Neste trabalho foram utilizadas munições do maior fabricante de cartuchos no Brasil (Companhia Brasileira de Cartuchos CBC). Foram comparados resíduos de munição convencional (Sinoxid) e de munição não-tóxica (Sintox) em tiros disparados a diversas distâncias, mostrando suas diferenças de composição e morfologia e que o resíduo Sintox contém partículas com composição semelhante àquelas encontradas no ambiente livre de tiros. A análise de fases do resíduo Sinoxid permitiu identificar uma nova categoria de partículas características, com composição e cristalografia específica (BaAl2O4), além das características (PbSbBa, PbBa) e consistentes (PbSb, PbBa, Pb, Sb, Ba) previstas pela norma. Nos resíduos de munição Sintox foram observadas composições contendo AlSiK, AlSi, Pb e AlSiCa. Destas categorias três tem composição semelhante a minerais abundantes na crosta terrestre (aluminossilicatos em geral). Nesta munição se propõe a presença de microesferulitos de chumbo, detectados com microscopia eletrônica de varredura, como evidência de disparo, com validade para os casos de armas em que se supõe o uso anterior ou concomitante de munição convencional, pois a origem provável destes esferulitos é a contaminação da arma com tiros anteriores (enchumbamento do cano). Exceto pela presença dos esferulitos de Pb, não se tem indicativo seguro para afirmar a origem de disparo de arma de fogo nestes resíduos. Do universo de fibras têxteis foram selecionadas fibras de vestimentas comuns entre vítimas de homicídio no Estado do Rio Grande do Sul e foram analisadas as alterações em fibras de tecidos submetidas a tiros, disparados em diferentes distâncias. Fibras de poliéster no tecido alvejado permitiram estimar distâncias de tiro tipo "encostadas" (contact) por fusão das fibras (fiber fusing), tipo "distâncias curtas", por apresentarem rompimento por fusão (fiber melting), enquanto que em distâncias maiores ocorre o rompimento mecânico. Fibras de algodão apresentaram apenas rompimento mecânico. Foi desenvolvida uma medida quantitativa através da medida com MEV do recobrimento de fibras com GSR, que mostra um decaimento exponencial em função da distância radial do furo do projétil, cuja constante de decaimento apresenta dependência da distância de disparo. / Given the high crime rate with firearms in Brazil, it is imperative to supply forensic laboratories with more subsidies on gunshot residues (GSR) from Brazilian ammunition and to analyze changes caused by firearm projectiles in textiles most commonly found at crime scenes. In this work we used ammunition from the leading supplier of cartridges in Brazil (Companhia Brasileira de Cartuchos CBC), and analyzed GSR from conventional ammunition (Sinoxid) and from non-toxic ammunition (Sintox), originated from shots fired at various distances from the target. Elemental analysis showed that both GSR are fundamentally different and that Sintox GSR is similar in composition to common environmental dust. The residue of the Sinoxid phase analysis identified a new category of characteristics particles, with specific composition and crystallography (BaAl2O4), next to the characteristic (PbSbBa, PbBa) and consistent (PBSB, PbBa, Pb, Sb, Ba) particles enumerated by the standard. In Sintox ammunition residue containing AlSiK, AlSi, Pb, and AlSiCa were found. Three of these categories have similar composition to abundant minerals in the earth's crust (aluminosilicates). To identify GSR from this ammunition, the presence of lead micro-spherulites detected with scanning electron microscopy, is proposed as evidence of shooting, valid for cases of weapons which had previous usage of conventional ammunition (weapon fouling). Among the many possible textile fibers, we selected those common on clothing of homicide victims in Southern Brazil (State of Rio Grande do Sul). Fiber modifications due to shots fired at different distances were analyzed. Polyester fibers in the targeted textiles allowed to estimate the firing distance of contact shots by fiber fusing, while at short distances fiber melting occurred. A higher distance only mechanical breakage was observed. Cotton fibers showed only mechanical disruption. The GSR-coverage of the fibers as a function of radial distance from the hole margin showed an exponential decay and the reciprocal decay constant showed a linear dependence on firing distance.
|
4 |
Caracterização dos resíduos de disparo e das alterações em fibras de tecidos atingidos por tiros de arma de fogo com microscopia eletrônica de varredura e espectrometria de raios X característicosFrank, Paulo Ricardo Ost January 2016 (has links)
Tendo em vista o alto índice de criminalidade com armas de fogo no Brasil, é imperativo que a perícia forense tenha mais subsídios sobre resíduos de tiro e alterações provocadas por tiros em têxteis comumente encontrados em cenas de crime. Neste trabalho foram utilizadas munições do maior fabricante de cartuchos no Brasil (Companhia Brasileira de Cartuchos CBC). Foram comparados resíduos de munição convencional (Sinoxid) e de munição não-tóxica (Sintox) em tiros disparados a diversas distâncias, mostrando suas diferenças de composição e morfologia e que o resíduo Sintox contém partículas com composição semelhante àquelas encontradas no ambiente livre de tiros. A análise de fases do resíduo Sinoxid permitiu identificar uma nova categoria de partículas características, com composição e cristalografia específica (BaAl2O4), além das características (PbSbBa, PbBa) e consistentes (PbSb, PbBa, Pb, Sb, Ba) previstas pela norma. Nos resíduos de munição Sintox foram observadas composições contendo AlSiK, AlSi, Pb e AlSiCa. Destas categorias três tem composição semelhante a minerais abundantes na crosta terrestre (aluminossilicatos em geral). Nesta munição se propõe a presença de microesferulitos de chumbo, detectados com microscopia eletrônica de varredura, como evidência de disparo, com validade para os casos de armas em que se supõe o uso anterior ou concomitante de munição convencional, pois a origem provável destes esferulitos é a contaminação da arma com tiros anteriores (enchumbamento do cano). Exceto pela presença dos esferulitos de Pb, não se tem indicativo seguro para afirmar a origem de disparo de arma de fogo nestes resíduos. Do universo de fibras têxteis foram selecionadas fibras de vestimentas comuns entre vítimas de homicídio no Estado do Rio Grande do Sul e foram analisadas as alterações em fibras de tecidos submetidas a tiros, disparados em diferentes distâncias. Fibras de poliéster no tecido alvejado permitiram estimar distâncias de tiro tipo "encostadas" (contact) por fusão das fibras (fiber fusing), tipo "distâncias curtas", por apresentarem rompimento por fusão (fiber melting), enquanto que em distâncias maiores ocorre o rompimento mecânico. Fibras de algodão apresentaram apenas rompimento mecânico. Foi desenvolvida uma medida quantitativa através da medida com MEV do recobrimento de fibras com GSR, que mostra um decaimento exponencial em função da distância radial do furo do projétil, cuja constante de decaimento apresenta dependência da distância de disparo. / Given the high crime rate with firearms in Brazil, it is imperative to supply forensic laboratories with more subsidies on gunshot residues (GSR) from Brazilian ammunition and to analyze changes caused by firearm projectiles in textiles most commonly found at crime scenes. In this work we used ammunition from the leading supplier of cartridges in Brazil (Companhia Brasileira de Cartuchos CBC), and analyzed GSR from conventional ammunition (Sinoxid) and from non-toxic ammunition (Sintox), originated from shots fired at various distances from the target. Elemental analysis showed that both GSR are fundamentally different and that Sintox GSR is similar in composition to common environmental dust. The residue of the Sinoxid phase analysis identified a new category of characteristics particles, with specific composition and crystallography (BaAl2O4), next to the characteristic (PbSbBa, PbBa) and consistent (PBSB, PbBa, Pb, Sb, Ba) particles enumerated by the standard. In Sintox ammunition residue containing AlSiK, AlSi, Pb, and AlSiCa were found. Three of these categories have similar composition to abundant minerals in the earth's crust (aluminosilicates). To identify GSR from this ammunition, the presence of lead micro-spherulites detected with scanning electron microscopy, is proposed as evidence of shooting, valid for cases of weapons which had previous usage of conventional ammunition (weapon fouling). Among the many possible textile fibers, we selected those common on clothing of homicide victims in Southern Brazil (State of Rio Grande do Sul). Fiber modifications due to shots fired at different distances were analyzed. Polyester fibers in the targeted textiles allowed to estimate the firing distance of contact shots by fiber fusing, while at short distances fiber melting occurred. A higher distance only mechanical breakage was observed. Cotton fibers showed only mechanical disruption. The GSR-coverage of the fibers as a function of radial distance from the hole margin showed an exponential decay and the reciprocal decay constant showed a linear dependence on firing distance.
|
5 |
Caracterização dos resíduos de disparo e das alterações em fibras de tecidos atingidos por tiros de arma de fogo com microscopia eletrônica de varredura e espectrometria de raios X característicosFrank, Paulo Ricardo Ost January 2016 (has links)
Tendo em vista o alto índice de criminalidade com armas de fogo no Brasil, é imperativo que a perícia forense tenha mais subsídios sobre resíduos de tiro e alterações provocadas por tiros em têxteis comumente encontrados em cenas de crime. Neste trabalho foram utilizadas munições do maior fabricante de cartuchos no Brasil (Companhia Brasileira de Cartuchos CBC). Foram comparados resíduos de munição convencional (Sinoxid) e de munição não-tóxica (Sintox) em tiros disparados a diversas distâncias, mostrando suas diferenças de composição e morfologia e que o resíduo Sintox contém partículas com composição semelhante àquelas encontradas no ambiente livre de tiros. A análise de fases do resíduo Sinoxid permitiu identificar uma nova categoria de partículas características, com composição e cristalografia específica (BaAl2O4), além das características (PbSbBa, PbBa) e consistentes (PbSb, PbBa, Pb, Sb, Ba) previstas pela norma. Nos resíduos de munição Sintox foram observadas composições contendo AlSiK, AlSi, Pb e AlSiCa. Destas categorias três tem composição semelhante a minerais abundantes na crosta terrestre (aluminossilicatos em geral). Nesta munição se propõe a presença de microesferulitos de chumbo, detectados com microscopia eletrônica de varredura, como evidência de disparo, com validade para os casos de armas em que se supõe o uso anterior ou concomitante de munição convencional, pois a origem provável destes esferulitos é a contaminação da arma com tiros anteriores (enchumbamento do cano). Exceto pela presença dos esferulitos de Pb, não se tem indicativo seguro para afirmar a origem de disparo de arma de fogo nestes resíduos. Do universo de fibras têxteis foram selecionadas fibras de vestimentas comuns entre vítimas de homicídio no Estado do Rio Grande do Sul e foram analisadas as alterações em fibras de tecidos submetidas a tiros, disparados em diferentes distâncias. Fibras de poliéster no tecido alvejado permitiram estimar distâncias de tiro tipo "encostadas" (contact) por fusão das fibras (fiber fusing), tipo "distâncias curtas", por apresentarem rompimento por fusão (fiber melting), enquanto que em distâncias maiores ocorre o rompimento mecânico. Fibras de algodão apresentaram apenas rompimento mecânico. Foi desenvolvida uma medida quantitativa através da medida com MEV do recobrimento de fibras com GSR, que mostra um decaimento exponencial em função da distância radial do furo do projétil, cuja constante de decaimento apresenta dependência da distância de disparo. / Given the high crime rate with firearms in Brazil, it is imperative to supply forensic laboratories with more subsidies on gunshot residues (GSR) from Brazilian ammunition and to analyze changes caused by firearm projectiles in textiles most commonly found at crime scenes. In this work we used ammunition from the leading supplier of cartridges in Brazil (Companhia Brasileira de Cartuchos CBC), and analyzed GSR from conventional ammunition (Sinoxid) and from non-toxic ammunition (Sintox), originated from shots fired at various distances from the target. Elemental analysis showed that both GSR are fundamentally different and that Sintox GSR is similar in composition to common environmental dust. The residue of the Sinoxid phase analysis identified a new category of characteristics particles, with specific composition and crystallography (BaAl2O4), next to the characteristic (PbSbBa, PbBa) and consistent (PBSB, PbBa, Pb, Sb, Ba) particles enumerated by the standard. In Sintox ammunition residue containing AlSiK, AlSi, Pb, and AlSiCa were found. Three of these categories have similar composition to abundant minerals in the earth's crust (aluminosilicates). To identify GSR from this ammunition, the presence of lead micro-spherulites detected with scanning electron microscopy, is proposed as evidence of shooting, valid for cases of weapons which had previous usage of conventional ammunition (weapon fouling). Among the many possible textile fibers, we selected those common on clothing of homicide victims in Southern Brazil (State of Rio Grande do Sul). Fiber modifications due to shots fired at different distances were analyzed. Polyester fibers in the targeted textiles allowed to estimate the firing distance of contact shots by fiber fusing, while at short distances fiber melting occurred. A higher distance only mechanical breakage was observed. Cotton fibers showed only mechanical disruption. The GSR-coverage of the fibers as a function of radial distance from the hole margin showed an exponential decay and the reciprocal decay constant showed a linear dependence on firing distance.
|
6 |
Desenvolvimento de métodos espectroanalíticos aplicados à química forense e alimentosJosé de Filgueiras Gomes, Maria 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T23:13:44Z (GMT). No. of bitstreams: 2
arquivo3260_1.pdf: 3652671 bytes, checksum: 5444c1a03be991d18a247fa870d61851 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2010 / Este trabalho está dividido em três partes. As duas primeiras tratam do desenvolvimento de métodos
espectroanalíticos aplicados a problemas qúimico e a terceira aborda a determinação do teor de mercúrio
presente em arroz. Na primeira parte é apresentado um método desenvolvido para determinação de cocaína
empregando um sistema de análise por injeção seqüencial acoplado a fluxo-batelada com detecção
espectrofotométrica, usando tiocianato de cobalto como reagente complexante Nessa reação duas fases são
encontradas: a superior (rosa) contendo um excesso da solução de tiocianato de cobalto e uma fase orgânica
(azul) contendo o complexo de cocaína- tiocicanato de cobalto em clorofórmio. Amostras e reagentes são
inseridas empregando uma válvula de injeção seqüencial entre duas bolhas de ar dentro de uma câmara
reacional. Uma fibra óptica conectada à câmara registrou o sinal de absorbância em 630 nm. Os limites de
detecção e quantificação foram de 29,4 mg L-1 e 98 mg L-1, respectivamente. O desvio padrão relativo foi de
4,9% para a solução contendo 400 mg L-1 (n = 10), com linha de base estável. A freqüência analítica foi de
12 determinações por hora e resposta linear de 100 a 1000 mg L-1. Na segunda parte, a espectroscopia de
emissão em plasma induzido por laser (LIBS) foi empregada para a detecção de resíduos de disparo de arma
de fogo (GSR) nas mãos de indivíduos que realizaram ou não disparos. Para desenvolver o procedimento,
115 amostras foram obtidas pressionando um pequeno pedaço de fita adesiva contra a região dorsal das mãos
de não-atiradores, atiradores após o disparo e de atiradores após terem lavado as mãos com sabão e água. As
fitas foram analisadas diretamente em um equipamento LIBS baseado em um policromador echelle com
resolução temporal construído em laboratório. Os espectros foram obtidos a partir da aplicação de um único
pulso de laser em 20 locações diferentes, espalhadas uniformemente sobre a superfície da fita, para assegurar
uma amostragem eficiente na detecção de resíduos de disparo. Os espectros mostram uma assinatura com
linhas de emissão características de bário e chumbo. Quando os dados espectrais foram submetidos à técnica
de reconhecimento de padrão SIMCA (Modelagem Independente e Flexível por Analogia de Classe),
atiradores e não-atiradores foram corretamente classificados. O método baseado em LIBS e SIMCA
demonstrou ser não-destrutivo da evidência do crime e permitiu discriminar as amostras coletadas de
voluntários não-atiradores e atiradores, mesmo após a lavagem das mãos. Na terceira parte do trabalho foi
desenvolvido um método para determinação de mercúrio em amostras de arroz utilizando a espectrometria
de fluorescência atômica com geração de vapor frio (CV-AFS). O método é baseado na digestão prévia das
amostras em forno de micro-ondas com HNO3 e H2O2 seguida de uma diluição com água contendo
KBr/KBrO3 e hidroxilamina e o redutor SnCl2 em HCl usando calibração externa. A interferência dos
vapores óxidos nitrosos foi avaliada usando uma amostra de referência certificada. O limite de detecção do
método foi 0,9 ng g-1 com percentual de recuperação de 95 ± 4% para uma adição de concentração de
5 ng g−1. A concentração de mercúrio encontrado nas 24 amostras de arroz de diferentes origens estava em
uma faixa de 1,3 a 7,8 ng g−1. A faixa dinâmica foi de 0,025 a 0,2 ng L-1
|
7 |
Contribui??o ao estudo diagn?stico dos ferimentos p?rfuro-contusos por proj?teis de arma de fogo civil na pele humana com enfoque histopatol?gicoBaptista, Marcus Vinicius 31 July 2007 (has links)
Made available in DSpace on 2016-01-26T12:51:16Z (GMT). No. of bitstreams: 1
marcusviviciusbaptista_dissert.pdf: 5989384 bytes, checksum: 709f4e156c11b3804c116e8d1679f733 (MD5)
Previous issue date: 2007-07-31 / In Brazil, there was a significant increase of deaths due to external causes resulting from wounds of firearm projectiles. This kind of wound is the third cause of Brazilians? deaths, after cardiac and cerebral vascular diseases. Taking into account the necessity of public and social order, both the Medicine and Forensic Justice have interest in victims of wounds of external causes. In this case, Justice searches in the medical science a set of juridical knowledge to help it to defend the rights and interests of men and society: this is the Forensics Medicine. The Forensic Physician has to be able to provide the causa mortis as well to describe the wounds of the Justice interest. In the cases associated with firearms, this physician has to determine if the orifice from the projectile in the body is of entrance or exit. This is very important according to the juridical and proceeding point of view. The firearm projectiles cause in the human skin several typical wounds; however, the shot direction or if the wound occurred due to the entrance or the exit of the projectile are not always determined macroscopically by the forensic physician. Therefore, other means, as the histological, to provide an accurate diagnosis should be taken into account. This study analyzed macroscopically and microscopically 14 wounds of entrance and their 14 wounds of exits, comparing data with the related in the literature. This study showed that hystopathological analysis of wounds due to firearm projectiles provides an effective diagnosis of the entrance and exit orifice. Coagulation necrosis of keratinocytes associated with subepidermal fissure (effects of burn injuries) is a pathognomonic feature of the entrance orifice, whereas the presence of adipose, muscle and bone tissues in the derm is characteristic of the exit orifice. / No Brasil, nos ?ltimos anos, houve um aumento acentuado de mortes por causas externas, devido a ferimentos de proj?teis de arma de fogo. Atualmente, os ferimentos causados por armas de fogo s?o a terceira causa de morte entre os brasileiros, atr?s somente das doen?as card?acas e das c?rebro-vasculares. As v?timas dos ferimentos por causas externas s?o de interesse da Medicina e tamb?m da Justi?a, levando-se em considera??o as necessidades de ordem p?blica e social. Neste caso, a Justi?a busca na ci?ncia m?dica um conjunto de conhecimentos extrajur?dicos para auxili?-la a defender os direitos e os interesses dos homens e da sociedade: ? a Medicina Legal. Compete ao M?dico Legista estabelecer a causa mortis e descrever os ferimentos de interesse da Justi?a. Nos casos que se correlacionam com armas de fogo, compete ao mesmo determinar se o orif?cio decorrente do proj?til no corpo humano ? de entrada ou de sa?da, tendo este fato suma import?ncia do ponto de vista jur?dico e processual. Os proj?teis de arma de fogo ocasionam na pele humana uma s?rie de ferimentos t?picos, mas nem sempre possibilitam o m?dico legista estabelecer, do ponto de vista macrosc?pico, a dire??o do tiro ou se um ferimento foi ocasionado pela entrada do proj?til ou pela sua sa?da. Deve-se, ent?o, lan?ar m?os de meios mais precisos ? histol?gicos ? para se estabelecer o diagn?stico de certeza. Este estudo analisou 14 ferimentos de entrada e suas 14 respectivas sa?das, do ponto de vista macrosc?pico e microsc?pico, comparando-se com os dados j? existentes na literatura. Este estudo demonstrou que a an?lise histopat?logica dos ferimentos ocasionados por proj?teis de arma de fogo fornece substrato para o diagn?stico mais acurado do orif?cio de entrada e de sa?da, sendo que a necrose de coagula??o dos ceratin?citos associada ? fenda sub-epid?rmica (efeitos de les?o por queimadura) ? caracter?stica de orif?cios de entrada e a presen?a de tecido adiposo, tecido muscular e tecido ?sseo, na derme, ? caracter?stica de orif?cio de sa?da.
|
8 |
Ferimento facial por projétil de arma de fogo: avaliação dos resultados e complicações de 52 pacientes tratadosGaetti-Jardim, Ellen Cristina [UNESP] 10 June 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-06-10Bitstream added on 2014-06-13T19:41:00Z : No. of bitstreams: 1
jardim_ecg_dr_araca.pdf: 202114 bytes, checksum: 359bbd531b990ad18d3aa44134a1f114 (MD5) / Traumas faciais em decorrência de ferimento por projétil de arma de fogo produzem lesões pérfuro-contuso que podem variar de acordo com o calibre da arma usada, da distância a partir do qual o paciente é baleado e da textura do tecido atingido. O tratamento de lesões maxilo-faciais por projétil de arma de fogo é ainda controverso em relação ao momento ótimo para a intervenção. A maioria dos autores recomenda tratamento conservador como a restauração oclusal e bloqueio maxilomandibular; postulamos que muitas lesões faciais por projétil de arma de fogo podem ser tratadas precocemente com técnicas de cirurgia aberta e fixação com sistemas de placas e parafusos. Nesse sentido, estudo retrospectivo de 12 anos - 2001 a 2012 - foi realizado buscando avaliar os resultados e complicações nos pacientes tratados por ferimentos por projétil de arma de fogo no esqueleto facial, tendo como elemento comparativo o tratamento indicado/realizado para os mesmos, tanto os pacientes que receberam reparo imediato e redução aberta e os que receberam tratamento cirúrgico fechado. Justifica-se a realização deste trabalho, já que ferimentos por projétil de arma de fogo faciais normalmente são associados com fraturas expostas que requerem intervenção cirúrgica imediata para limitação do dano e que em muitos casos podem ser tratados primariamente de forma definitiva, destinado a reparar o osso e os tecidos moles tão logo as condições clínicas permitam. De acordo com os resultados obtidos os pacientes vítimas de PAF facial podem ser tratados na urgência primariamente de forma aberta, pois os índices de complicação comparativamente ao grupo tratado de forma eletiva tardiamente foram similares / Facial trauma due to injury by gunshot wounds produce penetrating injuries that may vary according to the caliber of the weapon used, the distance from which the patient is shot and tissue texture achieved. The treatment of maxillofacial injuries by projectile weapon-of-fire is still controversial regarding the optimal time for intervention. Most authors recommend conservative treatments such as occlusal restoration and lock jaw; postulate that many facial injuries by projectile weapon fire-can be treated early with open surgical techniques and fixation with plates and screws systems. Accordingly, retrospective study of 12 years - from 2001 to 2012 - was held aiming to evaluate the results and complications in patients treated for injuries projectile weapon fire-in facial skeleton, taking as a baseline the indicated treatment / performed for same with patients who received immediate repair and open reduction and those receiving surgery closed. Justified this work, since injuries projectile weapon fire-are typically associated with facial fractures requiring immediate surgical intervention for damage limitation and that in many cases can be definitively treated primarily aimed at repair the bone and soft tissues as soon as clinical conditions permit. According to the results obtained for patients suffering from PAF face can be treated in an open urgency primarily because the complication rates compared to the group treated electively later were similar
|
9 |
Ferimento facial por projétil de arma de fogo : avaliação dos resultados e complicações de 52 pacientes tratados /Gaetti-Jardim, Ellen Cristina. January 2013 (has links)
Orientador: Elio Hitoshi Shinohara / Banca: Nicolas Homsi / Banca: Osvaldo Magro Filho / Banca: Thallita Pereira Queiroz / Banca: Wilson Roberto Poi / Resumo: Traumas faciais em decorrência de ferimento por projétil de arma de fogo produzem lesões pérfuro-contuso que podem variar de acordo com o calibre da arma usada, da distância a partir do qual o paciente é baleado e da textura do tecido atingido. O tratamento de lesões maxilo-faciais por projétil de arma de fogo é ainda controverso em relação ao momento ótimo para a intervenção. A maioria dos autores recomenda tratamento conservador como a restauração oclusal e bloqueio maxilomandibular; postulamos que muitas lesões faciais por projétil de arma de fogo podem ser tratadas precocemente com técnicas de cirurgia aberta e fixação com sistemas de placas e parafusos. Nesse sentido, estudo retrospectivo de 12 anos - 2001 a 2012 - foi realizado buscando avaliar os resultados e complicações nos pacientes tratados por ferimentos por projétil de arma de fogo no esqueleto facial, tendo como elemento comparativo o tratamento indicado/realizado para os mesmos, tanto os pacientes que receberam reparo imediato e redução aberta e os que receberam tratamento cirúrgico fechado. Justifica-se a realização deste trabalho, já que ferimentos por projétil de arma de fogo faciais normalmente são associados com fraturas expostas que requerem intervenção cirúrgica imediata para limitação do dano e que em muitos casos podem ser tratados primariamente de forma definitiva, destinado a reparar o osso e os tecidos moles tão logo as condições clínicas permitam. De acordo com os resultados obtidos os pacientes vítimas de PAF facial podem ser tratados na urgência primariamente de forma aberta, pois os índices de complicação comparativamente ao grupo tratado de forma eletiva tardiamente foram similares / Abstract: Facial trauma due to injury by gunshot wounds produce penetrating injuries that may vary according to the caliber of the weapon used, the distance from which the patient is shot and tissue texture achieved. The treatment of maxillofacial injuries by projectile weapon-of-fire is still controversial regarding the optimal time for intervention. Most authors recommend conservative treatments such as occlusal restoration and lock jaw; postulate that many facial injuries by projectile weapon fire-can be treated early with open surgical techniques and fixation with plates and screws systems. Accordingly, retrospective study of 12 years - from 2001 to 2012 - was held aiming to evaluate the results and complications in patients treated for injuries projectile weapon fire-in facial skeleton, taking as a baseline the indicated treatment / performed for same with patients who received immediate repair and open reduction and those receiving surgery closed. Justified this work, since injuries projectile weapon fire-are typically associated with facial fractures requiring immediate surgical intervention for damage limitation and that in many cases can be definitively treated primarily aimed at repair the bone and soft tissues as soon as clinical conditions permit. According to the results obtained for patients suffering from PAF face can be treated in an open urgency primarily because the complication rates compared to the group treated electively later were similar / Doutor
|
10 |
Estudo por tomografia computadorizada helicoidal com múltiplas fileiras de detectores em vítimas de ferimento por arma de fogo abdominal / Multi-detector row computed tomography study in abdominal gunshot wound victimsMelo, Ernesto Lima Araujo 03 June 2009 (has links)
O principal objetivo deste estudo foi testar a capacidade da tomografia computadorizada helicoidal com múltiplas fileiras de detectores (TCMD) na identificação/exclusão de lesões em vítimas de ferimento por arma de fogo (FAF) abdominal. Os achados de imagem foram comparados aos cirúrgicos em todos os pacientes da amostra. A TCMD demonstrou elevada acurácia na avaliação de órgãos sólidos, vísceras ocas, grandes vasos e diafragma. Quase a metade dos pacientes (45,2%) não exibiu lesões que necessitassem obrigatoriamente de correção cirúrgica. A TCMD mostrou-se excelente na avaliação dos pacientes da amostra, podendo contribuir com informações importantes ao manejo de vítimas de FAF abdominal. / The main objective of this study was to test the ability of multi-detector row computed tomography (MDCT) in the identification/exclusion of lesions in abdominal gunshot wound (GW) victims. The imaging findings were compared with the surgical ones in all of the studied patients. MDCT demonstrated elevated accuracy in the evaluation of solid organs, hollow viscus, great vessels, and diaphragm. Almost half of the patients (45.2%) did not show lesions requiring obligatory surgical interventions. MDCT showed to be excellent in the evaluation of the studied patients, and can contribute with important information for the management of abdominal GW victims.
|
Page generated in 0.0888 seconds