• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 16
  • 16
  • 16
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A influência do sistema de fachada viva em manta no ciclo de vida energético de uma residência unifamiliar em clima tropical

Oliveira, Luciana Bandeira de January 2015 (has links)
Orientador : Prof. Dr. Sérgio Fernando Tavares / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Construção Civil. Defesa: Curitiba, 23/05/2015 / Inclui referências : f. 81-86 / Area de concentração : Ambiente construído / Resumo: Este trabalho tem como motivação a busca por soluções mais eficientes na arquitetura, que tragam conforto e eficiência energética às edificações. As fachadas vegetais, utilizadas há mais de 2.000 anos, têm sido atualmente objeto de estudo em diversos países, devido a suas propriedades benéficas ao edifício e ao meio urbano, tais como a redução do consumo energético com climatização, redução de ilhas de calor, mitigação dos gases do efeito estufa, retenção de partículas poluentes do ar, resgate da biodiversidade e bem estar psicológico dos usuários do edifício e de seu entorno. O clima brasileiro, com abundância de radiação solar, parece ideal para a implantação destes sistemas, sobretudo num momento em que há uma demanda crescente por energia elétrica e uma necessidade evidente de economia no consumo. Os sistemas de fachadas vivas, ou living wall systems, consistem em uma tecnologia de fachadas vegetais, de conjuntos de módulos ligados às paredes, onde o enraizamento das plantas se dá na própria estrutura e não no chão. A utilização desta estrutura de suporte permite a utilização de uma maior variedade de espécies vegetais, que sobrevivem com pouco ou nenhum solo, por meio de técnicas de hidroponia, e conferem um efeito estético inovador às fachadas vegetais. Além disso, pesquisas apontam que os sistemas de fachadas vivas possuem capacidade de isolamento térmico superior às fachadas verdes convencionais, compostas de plantas trepadeiras que se aderem à parede ou a estruturas auxiliares de suporte. No entanto, a estrutura necessária para suporte e manutenção dos sistemas de fachada viva, segundo estudos, apresenta altos impactos ambientais, devido aos materiais usados na estrutura e a exigência de manutenção e irrigação constantes, o que leva ao questionamento acerca da sustentabilidade dessa técnica. Este trabalho tem o objetivo de avaliar a sustentabilidade energético-ambiental do sistema de fachada viva em manta, através da análise do ciclo de vida energético, um método que analisa o gasto energético e os impactos relacionados, de um produto ou edificação durante toda sua vida útil, desde a extração da matéria prima até o descarte do mesmo. Três etapas auxiliam a construção desta ACVE: na primeira busca-se, através da revisão bibliográfica, conhecer os sistemas de fachadas vivas e suas características, além de compreender o método das análises de ciclo de vida e bases de dados de materiais e energia relacionada. A segunda etapa consiste na simulação de um protótipo de fachadas vivas, a fim de extrair do mesmo as propriedades físicas relacionadas à capacidade de isolamento térmico do sistema. A terceira etapa é a simulação termoenergética do sistema de fachada viva em manta, aplicado a seis modelos de uma mesma edificação residencial em clima tropical, variando a instalação de fachadas vivas em diferentes orientações, com o objetivo de quantificar a economia com climatização proporcionada pela fachada viva em cada situação, além de verificar o gasto energético durante o ciclo como um todo. Os resultados apontaram para reduções no gasto com climatização de 2,36% a 23,8%, no entanto, o sistema não foi considerado sustentável energeticamente, uma vez que a redução obtida na energia operacional não compensa o investimento energético com a instalação e manutenção das fachadas vivas, e ao final do ciclo de vida de 50 anos, os modelos com fachadas vivas ainda apresentaram gasto energético superior ao caso base, sem fachadas vivas. Palavras-chave: Sistemas de fachadas vivas; analises de ciclo de vida; análises energéticas; eficiência energética. / Abstract: This research is motivated by the search for more efficient solutions in architecture, which give comfort and energetic efficiency to buildings. The green façades have been used for over 2.000 years, and lately have been a study subject in many countries, due to their beneficial properties to the building and the urban environment, such as reducing energy consumption with artificial air conditioning, reducing the heat island effect, mitigation of greenhouse gases, retention of particulate air pollutants, biodiversity rescue and psychological well being of building users and its surroundings. Brazilian climate, with high levels of solar radiation, presents favorable conditions on implementing and studying this technology, particularly at a time when there is a growing demand for electricity and a clear need for economy in consumption. Living wall systems are a green façades technology, which are sets of modules linked to the wall, in which the plants rooting occurs in the own structure and not in the ground. The use of such support structure allows the use of a greater variety of plant species which survive with little or no soil using hydroponic techniques, and it provides an innovative aesthetic to the building. In addition, studies point that living wall systems presents superior thermal insulation capacity than conventional green façade, which needs vines or auxiliary structures to support climbing plants. However the necessary infrastructure to support and maintenance living wall systems, according to studies, has a high environmental impact, due to structure materials and the requirement for maintenance and constant irrigation, which leads to questions about the sustainability of this technique. This study aims to assess the sustainability of living wall systems with felt layers, by analyzing its energy life cycle, a method that analyzes the energetic consumption and related impacts of a product or building throughout its life, from the extraction of raw materials to its disposal. Three steps can help build this LCEA: first, through literature review, study the living wall systems and its characteristics, and understand the method of life cycle analysis and materials and energy related databases. The second step was to simulate a living wall system prototype, in order to find its physical properties related to the thermal insulation capacity of the system. And the third step was the thermal and energetic simulation of the living wall system with felt layers, applied to six models of the same residential building in a tropical climate zone, by varying the installation of living walls in different orientations, in order to quantify the savings provided by the air conditioning use reduction in each situation, and verify the hole energetic expenditure during the life cycle. The results point to energy savings around 2,36% to 23,8% with artificial air conditioning, but the system studies was not considered sustainable, since the reduction achieved in operation is not worth the energy investment with the installation and maintenance of the living wall system and at the end of the 50-year life cycle, models with living walls still had energy expenditure above the model without living wall systems. Keywords: Living wall systems; life cycle assessment; energy analysis, energy efficiency.
2

Sistemas baseados em conhecimento para aplicação de eficiência energética e conservação de energia para plantas industriais /

Buccieri, Gilberto Paschoal. January 2018 (has links)
Orientador: José Alexandre Matelli / coorientador: José Antonio Perrella Balestieri / Banca: Rubens Alves Dias / Banca: Paloma Maria Silva Rocha Rizol / Banca: Jonny Carlos da Silva / Banca: Elisangela Martins Leal / Resumo: Este trabalho apresenta o desenvolvimento de um protótipo de sistema especialista (SE) dotado de um módulo de geração de explicação (MGE) para diagnóstico preliminar de eficiência energética em plantas industriais, considerando as características fundamentais de operação e manutenção dessas plantas. Embora a capacidade de explicar processos de raciocínio distinga o SE de outros sistemas de apoio à decisão, disponibilizar um MGE ajuda a promover uma análise crítica das decisões tomadas pelo SE. Em adição, o MGE é muito útil também na validação da base de conhecimento, permitindo detectar erros semânticos do sistema e monitorar detalhes do processo de inferência, o que pode levar a uma redução de tempo de desenvolvimento e maior aceitação do sistema, aumentando dessa forma sua confiabilidade e principalmente, sua credibilidade. A base de conhecimento do sistema foi construída a partir da experiência de especialistas multidisciplinares da área de eficiência energética industrial, o que é certamente um recurso valioso em um contexto de gestão do conhecimento (GC) organizacional. A GC torna o conhecimento humano especializado em valor duradouro, criando uma memória corporativa por meio de ações de compartilhamento e retenção, o que pode contribuir para a melhoria contínua dos processos, criação de valor e manutenção de vantagens competitivas. Para demonstrar as possibilidades de melhoria de eficiência energética, os principais sistemas de utilidades de uma planta industrial são ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents the development of an expert system prototype (ES) with an explanation facility module (EFM) for preliminary diagnosis of energy efficiency guidelines in industrial plants, considering the fundamental characteristics of operation and maintenance of these plants. Although the ability to explain its own reasoning distinguishes ES from other decision support systems, providing an EFM contributes to promote a critical analysis of the decisions taken by the ES. In addition, the EFM is also very useful in validating the knowledge base, because it facilitates the detection of semantic errors and allows a better monitoring of the inference process. Because of that, the EFM can reduce the development time and contribute to a broader acceptance of the system, which positively impacts its reliability and credibility. The knowledge base of the system was built on the experience of multidisciplinary experts in the field of industrial energy efficiency that is certainly a valuable resource in an organizational knowledge management (KM) context. The KM becomes the human knowledge in permanent value by creating a corporate memory through sharing and retention actions that may contribute to continuous improvement of processes, value creation and maintaining competitive advantage. In order to properly demonstrate the possibilities of energy efficiency improvement, the main utility systems of an industrial plant are analyzed individually. To do so, such systems are classified... (Complete abstract click electronic access below) / Doutor
3

Análise de métodos de determinação do zoneamento bioclimático brasileiro a partir do estudo de caso de Colatina – ES / Analysis of determination methods for brazilian bioclimatic zoning based on the case study of the city of Colatina, ES

Amorim, Alexandre Cypreste 19 March 2015 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-05-13T14:32:13Z No. of bitstreams: 1 texto completo.pdf: 3256560 bytes, checksum: d3644e271a217ced3765f965fa332dcd (MD5) / Made available in DSpace on 2016-05-13T14:32:13Z (GMT). No. of bitstreams: 1 texto completo.pdf: 3256560 bytes, checksum: d3644e271a217ced3765f965fa332dcd (MD5) Previous issue date: 2015-03-19 / O desempenho térmico e energético de uma edificação é relacionado diretamente com as condições climáticas, representadas principalmente pela temperatura do ar, velocidade e direção do vento, umidade e radiação solar, além de outras variáveis. Neste contexto, a utilização de dados climáticos é essencial para que profissionais da área de projeto possam conceber edificações dentro do conceito de arquitetura bioclimática. No Brasil, onde as edificações, em geral, representam 52% do consumo de energia elétrica, a concepção de edificações levando em conta o conhecimento das características climáticas onde estas serão executadas torna-se importante ferramenta para isto. Trabalhar com a integração entre edificação e clima desde a concepção do edifício é condição favorável a que se tenha um desempenho ambiental adequado, como também um bom nível de conforto aos seus usuários. O desenvolvimento e conhecimento de zonas bioclimáticas possibilita a concepção de edifícios que possuam estratégias direcionadas para construções que sejam adequadas a cada zona em particular. Nesta ótica, o objetivo deste trabalho foi avaliar a adequação dos componentes construtivos de paredes na cidade de Colatina/ES, conforme critérios de desempenho propostos no RTQ-R, de acordo com os métodos de determinação do zoneamento bioclimático brasileiro (atual e revisão). O método consistiu na obtenção de dados para confecção de arquivos climáticos (TRY e TMY2) para Colatina/ES. Com os arquivos climáticos criados, identificou-se o enquadramento bioclimático adequado para Colatina/ES de acordo com o Zoneamento Bioclimático Brasileiro da NBR 15220-03 e de suas propostas de revisão. Depois, para análise do desempenho de componentes construtivos, uma edificação real escolhida na cidade de Colatina/ES foi simulada no EnergyPlus, aplicando-se os arquivos climáticos de Colatina/ES, Vitória/ES e Linhares/ES e Aimorés/MG. Os resultados mostraram que pelo atual zoneamento, Colatina/ES é classificada como ZB8, assim como Vitória e Linhares. Pelas propostas de revisão, a cidade de Colatina/ES poderia ser classificada como uma zona diferente de todas as outras ou na mesma zona de Aimorés/MG, dependendo da proposta de revisão do Zoneamento, demonstrando que a escolha do método de revisão pode apresentar resultados bem diferentes em termos de classificação. Ao se analisar os resultados por método de simulação, o desempenho dos componentes construtivos demonstraram uma proximidade com a proposta 03 de revisão do Zoneamento Bioclimático, na qual Colatina/ES não se insere em nenhuma zona bioclimática das outras cidades analisadas. / The thermal performance and energy use in buildings is directly related to weather conditions, mainly represented by air temperature, wind and, humidity, solar radiation, and other variables. In this context, weather history is essential for professionals who designes buildings under the concept of bioclimatic architecture. In Brazil, where buildings represent 52% of electricity consumption turns the knowledge of weather conditions into, an important tool for civil constructions. An integration between a weather-designed construction and local weather allows an adequate environmental performance, as well as a good comfort level for users. The development and knowledge of bioclimatic zones allows the design of buildings with specific properties for each particular zone. Using this concept as a starting point, this study aims to evaluate the suitability of non load-bearing masonry wall of buildings in the city of Colatina (Espírito Santo State), according to RTQ-R proposed performance criteria in RTQ-R, considering Brazilian Bioclimatic Zoning (current and review proposals) method. The method consists in obtaining weather data for creating typical weather year files (test reference year - TRY and typical meteorological year - TMY) to the city of Colatina. From these weather files and according to Brazilian Bioclimatic Zoning, it was stated in which bioclimatic zone the city of Colatina belonged. Then, in order to analyse building’s walls performance, thermal models were simulated in EnergyPlus program, considering, an local residential building in Colatina,. The following cities’ weather files were applied: Colatina, Vitória, Linhares, and Aimorés. Results indicated that for the current bioclimatic zoning, Colatina is classified as ZB8, as well as Vitoria and Linhares. By review proposals, the city of Colatina could be classified in a different bioclimatic zone or in the same bioclimatic zone of Aimorés. When analyzing the results by simulation method, the performance of non load-bearing masonry wall components demonstrate that Colatina is not included in the expected Bioclimatic Zone.
4

Proposta de simplificação do RTQ-R / Proposal to simplify the RTQ-R

Telles, Carolina de Paula 09 June 2016 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2016-09-02T17:26:12Z No. of bitstreams: 1 texto completo.pdf: 2157602 bytes, checksum: 18b1384f805a675fa6a4843b97d7278f (MD5) / Made available in DSpace on 2016-09-02T17:26:12Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2157602 bytes, checksum: 18b1384f805a675fa6a4843b97d7278f (MD5) Previous issue date: 2016-06-09 / Fundação de Amparo à Pesquisa do Estado de Minas Gerais / O consumo energético residencial vem crescendo nos últimos anos e, no Brasil, ações que visam o incremento da eficiência energética nestas edificações resultaram no Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Residenciais (RTQ-R). O regulamento consiste em uma certificação nacional pertencente ao Programa Brasileiro de Etiquetagem do Inmetro e apresenta os métodos prescritivo e de simulação para avaliação do desempenho energético: o primeiro a faz através de equações; o segundo avalia o desempenho por meio de simulação computacional. A efetividade do RTQ-R depende de métodos apropriados de avaliação e sua aceitação pelo mercado. Entretanto, foi constatada baixa aplicabilidade do RTQ-R ao longo dos cinco anos em que o regulamento se encontra em vigor. Partindo-se da hipótese de que a certificação apresenta margem de simplificação, este trabalho propõe um método de avaliação simplificado do nível de eficiência energética para edificações naturalmente ventiladas do setor residencial para o PBE Edifica. A proposta focou na simplificação do cálculo do equivalente numérico da envoltória (EqNumEnv) e do dimensionamento do sistema de aquecimento solar. O método consiste na definição de modelos representativos das edificações residenciais brasileiras existentes; na análise da influência das variáveis da equação do método prescritivo nos indicadores de consumo do RTQ-R; e no desenvolvimento e validação do método de avaliação proposto a partir da comparação dos resultados obtidos pelo método atual e o proposto. A simplificação do EqNumEnv resultou em equações reduzidas que variam de acordo com a tipologia e zona bioclimática (ZB) da edificação avaliada. A proposta foi validada com um percentual de convergência dos resultados variando de 97% a 100%, de acordo com a ZB analisada. A proposta para o sistema de aquecimento de água consistiu na adaptação do cálculo da fração solar anual, realizado por meio dos dados mensais, pelo cálculo da fração solar a partir dos dados das médias anuais. A eficácia do método foi verificada para dezesseis casos e a diferença média dos resultados do método simplificado e do vigente foi de 0,00905. Espera-se que o método simplificado contribua para a consolidação do RTQ-R no território nacional. / The residential energy consumption has been growing in recent years and, in Brazil, some actions that aimed to increase energy efficiency in buildings resulted in the Technical Quality Requirements for Energy Efficiency Level of Residential Buildings (RTQ-R). The regulation is a national certification that is part of the the Brazilian Labeling Program of Inmetro and it presentes a prescriptive and a simulation method to evaluate the energy performance: the first is through equations; the second is through computer simulation. The effectiveness of RTQ-R depends on appropriate evaluation methods and its acceptance by the building market. However, a low use of RTQ-R was observed over the five years in which the regulation is active. Starting from the hipothesis that the certification presents scope that can be simplified, this study proposes a simplified method of evaluating the energy efficiency level for naturally ventilated buildings in the residential sector for PBE Edifica. The proposal was to simplify the calculation of the numerical equivalent of the envelope (EqNumEnv) and the water heating system. The method consists in defining representative models of existing Brazilian residential buildings; analysis of the influence of the variables of the prescriptive method equation in consumption indicators RTQ-R; and the development and validation of the proposed evaluation method from the comparison between the results obtained by the present method and the proposed. The simplification of EqNumEnv resulted in reduced equations that vary with the type and bioclimatic zone (ZB) of evaluated building. The proposal has been validated as a percentage of convergence of results ranging of 97% to 100%, according to ZB analyzed. The proposal for the water heating system was adaptation of the calculation of annual solar fraction, conducted through monthly data, by calculating the solar fraction from the annual data. He effectiveness of the method was verified in sixteeen cases and the average difference of the results of simplified method and of current was 0,00905. It is expected that the simplified method enables the consolidation of the RTQ-R in Brasil.
5

Transmissão de calor em regime periodico : efeito da inercia termica em fechamentos opacos

Granja, Ariovaldo Denis, 1963- 31 July 2018 (has links)
Orientador : Lucila Chebel Labaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-31T23:08:17Z (GMT). No. of bitstreams: 1 Granja_AriovaldoDenis_D.pdf: 766890 bytes, checksum: cfaee3ae0e3e66bb8d376d2619bda5ad (MD5) Previous issue date: 2002 / Doutorado
6

Desempenho termoenergético da utilização de telhado vegetal em edificação no clima amazônico

MARINHO, Dircirene Tavares 19 March 2013 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-05-26T11:25:37Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesempenhoTermoenergeticoUtilizacao.pdf: 9405332 bytes, checksum: 6db1c2227ae6d91753b4e18c4f06cc0c (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-06-02T13:14:00Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesempenhoTermoenergeticoUtilizacao.pdf: 9405332 bytes, checksum: 6db1c2227ae6d91753b4e18c4f06cc0c (MD5) / Made available in DSpace on 2017-06-02T13:14:00Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesempenhoTermoenergeticoUtilizacao.pdf: 9405332 bytes, checksum: 6db1c2227ae6d91753b4e18c4f06cc0c (MD5) Previous issue date: 2013-03-19 / O desempenho termoenergético de toda obra da construção civil decorre da tomada de decisões na fase projetual e as caracteristicas termofisicas dos materiais empregados devem ser considerados. O fenomeno termofísico da inércia presente nos telhados vegetais oferece resistencia ao transporte de massa termica para o interior da edificação, reduzindo a demanda de energia elétrica necessaria para seu acondicionamento climático; ao mesmo tempo, o baixo albedo da vegetação dos telhados vegetais contribui para mitigar os efeitos das ilhas de calor em ambientes urbanos. O necessário estudo bioclimático e o microclimático determinarão a escolha dos materiais construtivos adequados, especialmente no que tange à proteção de superfícies da envoltória expostas à carga térmica solar. Este trabalho irá tratar da comprovação experimental do desempenho termoenergético de uma edificação coberta com grama em local onde predomina a vegetação, no Parque de Ciência e Tecnologia do Guamá, Campus Universitário da Universidade Federal do Pará. O objetivo é a analise da atenuação dos picos de calor decorrente da inércia térmica dos materiais utilizados, inferindo desempenho energético pela redução do uso de refrigeração ativa. Foram caracterizados os microclimas externos e internos através de valores obtidos de temperatura e umidade relativa do ar, assim como a evolução das condições ambientais internas em duas fases, com a laje descoberta e após com a aplicação do telhado vegetal. Os resultados indicam favorável desempenho do telhado vegetal na redução do fluxo de calor através da laje, apresentando potencial redução na temperatura do ar interior e a conseqüente eficiência energética em edificações no clima amazônico. / The thermoenergetic performance of all construction work stems from the decisionmaking of the initial phase, and the thermo-physical characteristics of the materials used must be considered. The thermo-physical phenomenon of inertia in the roof vegetable offers resistance to the transport of thermic charge to inside the edification, reducing the demand of the electric energy needed to its climatic conditioning. At the same time, the low albedo of the roof vegetable contributes to mitigate the effects of the heat islands in urban environments. The bioclimatic and microclimatic study needed will determine the choice of the suitable construction materials, especially regarding the protection of surfaces exposed to solar heat load. This work deals with the experimental verification of the thermoenergetic performance of a room covered with grass in a place where the vegetation is predominant, in the Parque de Ciência e Tecnologia do Guamá, Campus da Universidade Federal do Pará. The key objective was to examine the thermal response of the slab by proving mitigation of heat spikes by physical phenomenon of thermal inertia, implying favorable results of energy performance by reducing the use of active cooling. It was performed preliminary characterization of the indoor and outdoor microclimate through the obtained values of temperature and relative humidity of air, and observed the evolution of internal environmental conditions in two phases, with the slab discovered and after application of vegetation. The quantitative results showed favorable performance of the roof vegetation in the moderation of heat flow through the slab, contributing to the reduction of the temperature of indoor air and consequent energy efficiency in buildings in Amazonian climate.
7

Desempenho térmico de coberturas vegetais em edificações na cidade de São Carlos-SP. / Thermal performance of planted roofs in buildings in the city of São Carlos-SP.

Morais, Caroline Santana de 20 April 2004 (has links)
Made available in DSpace on 2016-06-02T20:09:09Z (GMT). No. of bitstreams: 1 DissCSM.pdf: 5942097 bytes, checksum: aa10644278ef67c179237773179fde27 (MD5) Previous issue date: 2004-04-20 / Planted roofs, known as green roofs as well, can positively contribute to the improvement of buildings thermal performance and cities climate. The advantages of the planted roofs have been object of study of several researchers along different countries. However, some quantitative data on this subject are still needed in the context of tropical climate. The aim of this work is to evaluate the thermal performance of a planted roof and how it influences the thermal protection of the building, in accordance with São Carlos climatic conditions. The investigations were implemented for not only winter, but summer too. During both periods, air relative humidity, surface and air temperature measurements were taken at the indoor and the outdoor environment of the building prototype. Moreover, a comparison between a bare roof and of a green roof was made, using the same building prototype. The outdoor surface temperature for the bare roof and the leaves, which cover the green roof, was estimated through a Jardim 1.0 computational program. Data of global solar irradiance and wind velocity, necessary to estimate the outdoor surface temperatures, were achieved through a weather station. The analysis were ordered according to the thermal performances of the roofs in each one of the situations, separately, and between one and other situation. By field measurements, during the winter and the summer, smaller thermal amplitudes were noticed for the green roof. In the winter, the green roof presented medium thermal amplitude 70% smaller than the bare roof. During the summer, the amount of heat coming into the building prototype was reduced by the green roof. These and other results indicate the major green roof capacity of reducing daily temperature variations and thermal ranges. It has been confirmed that planted roofs effectively contribute to improve the thermal benefits being both, cost and energy effective, for the buildings and their surrounding environment. / As vantagens das coberturas verdes têm sido objeto de estudo de vários pesquisadores em diferentes países, pois as mesmas podem contribuir positivamente para a melhora do clima nas cidades e do desempenho térmico dos edifícios, tanto no verão quanto no inverno. Este trabalho tem como objetivo geral avaliar, experimentalmente, o comportamento térmico de uma cobertura verde, em protótipo, submetida ao clima da região de São Carlos, em situação de inverno e de verão. Para tanto, foram monitoradas as lajes de coberturas com e sem vegetação, a fim de se obter dados de seus desempenhos térmicos. Para monitorar dados de temperaturas e umidades relativas do ar e temperaturas superficiais das faces internas das lajes, o material utilizado foi um sistema eletrônico de aquisição de dados. Por meio do programa Jardim 1.0, foram estimadas as temperaturas superficiais externas da laje sem vegetação e das folhas da camada de vegetação da cobertura verde. Os dados de irradiância solar global e velocidade do vento, necessários à estimativa dessas temperaturas superficiais externas, foram fornecidos pela estação climatológica da Escola de Engenharia de São Carlos. As análises foram ordenadas de modo a comparar os desempenhos térmicos das coberturas em cada uma das situações, separadamente, e entre uma situação e outra. No inverno a cobertura verde apresentou uma amplitude térmica média 70% menor que a da cobertura sem vegetação. No verão, entre as temperaturas do ar nos ambientes internos às coberturas ocorreram diferenças de até 5°C. Os valores obtidos mediante as comparações indicaram um desempenho mais satisfatório da cobertura verde, a qual se manteve mais estável e resistente às flutuações térmicas diárias, tanto no inverno quanto no verão. Estes resultados indicaram que a cobertura ajardinada dispõe de importante potencial de aplicação no clima considerado, sendo solução de custo relativamente baixo e podendo contribuir efetivamente para melhorar o conforto ambiental e a eficiência energética do ambiente construído.
8

Conservação de energia em edificios comerciais atraves da implementação de dispositivos de automação / Conservation of energy in commercial buildngs through the implementation of automation devices

Gomazako, Marcone Susumo 23 October 2007 (has links)
Orientador: Carlos Alberto Mariotoni / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-09T15:15:44Z (GMT). No. of bitstreams: 1 Gomazako_MarconeSusumo_D.pdf: 5293277 bytes, checksum: 54ecece1926586b33b8eb4664a564549 (MD5) Previous issue date: 2007 / Resumo: Este trabalho vem apresentar um panorama do sistema elétrico geralmente encontrado em construções comerciais de grande porte, com cerca de trinta anos de funcionamento, que operam de forma pouco eficiente para os parâmetros atuais, principalmente no seu sistema de ar condicionado central. Nessa construção (estudo), seu sistema de condicionamento ambiental representa um acréscimo na demanda energética de cerca de 60%, passando de 450.000 kWh/mês para 750.000 kWh/mês, e a troca desses equipamentos por mais modernos e eficientes, significaria grandes investimentos, tornando-se inviável no curto prazo. Com isso, elaborou-se um protótipo contendo dispositivos de automação, que podem ser incorporados ao sistema existente, sem grandes dificuldades, e minimizando os custos operacionais com o sistema. Esses dispositivos permitem um monitoramento mais eficiente, sem a necessidade desses investimentos, como a substituição de grandes equipamentos (compressores, chillers, etc.) que fazem parte do sistema de ar condicionado central. Esse protótipo permitiu demonstrar que com a aplicação desses dispositivos incorporados nesses sistemas, podem gerar uma economia de cerca de 20% no consumo de energia elétrica, que representa uma economia bastante significativa de 60.000 kWh/mês (neste caso) quando operado o sistema de ar condicionado, além de aliviar os recursos humanos disponibilizados para esse tipo de monitoramento / Abstract: This work comes to present a panorama of the electric system found usually in commercial constructions of great load, with about thirty years of operation, that operate in way a little efficient for the current parameters, mainly in her air conditioning system. In that construction (in study), her system of environmental conditioning represents an increment in the energy demand of about 60%, passing to the 450.000 kWh/month for 750.000 kWh/month, and the change of those equipments for more modern and efficient, it would mean great investments, becoming unviable in the short period. With that, a prototype was elaborated containing automation devices, that can be incorporate to the existent system, without great difficulties, and minimizing the operational costs with the system. Those devices allow a more efficient monitoring, without the need of those investments, as the substitution of great equipments (compressors, chillers, etc.) that they part of the system of air conditioned central. That prototype allowed to demonstrate that with the application of those incorporate devices in those systems, they can generate an economy of about 20% in the electric power consumption, that represents a quite significant economy of 60.000 kWh/month, (this case) when operated the system of conditioned air, besides relieving the human resources made available for that monitoring type / Doutorado / Recursos Hidricos, Energeticos e Ambientais / Mestre em Engenharia Civil
9

Análise de certificação de edificação pública de ensino e pesquisa visando nível A pelo RTQ-C através de ações de eficiência energética e análise econômica

RIBEIRO, Ricardo Bastos Piqueira 07 July 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-01-27T15:18:13Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseCertificacaoEdificacao.pdf: 3409495 bytes, checksum: b1d56892bffe0d6964bc1e8c788157c1 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-30T11:35:50Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseCertificacaoEdificacao.pdf: 3409495 bytes, checksum: b1d56892bffe0d6964bc1e8c788157c1 (MD5) / Made available in DSpace on 2017-01-30T11:35:50Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseCertificacaoEdificacao.pdf: 3409495 bytes, checksum: b1d56892bffe0d6964bc1e8c788157c1 (MD5) Previous issue date: 2016-07-07 / Esta dissertação apresenta a análise de eficiência energética predial feita no edifício do Ceamazon, laboratório de pesquisas vinculado à Universidade Federal do Pará. Para este estudo foi utilizada a metodologia prescritiva do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Comerciais, de Serviços e Públicas – RTQ-C. A análise energética do RTQ-C envolve três parâmetros distintos: a envoltória da edificação, o sistema de iluminação artificial e o sistema de condicionamento de ar. O estudo dos dados de cada um destes sistemas fornece material para os cálculos necessários no método, que resultarão em um equivalente numérico para cada um, representando a eficiência de cada sistema. A análise desta dissertação foi efetuada principalmente nos sistemas de iluminação artificial e condicionamento de ar, visto que uma análise prévia dos dados de envoltória do prédio já havia coletado bons resultados. O objetivo primário da dissertação foi de enquadrar a edificação em questão no nível A de eficiência energética proposto pelo regulamento. Desta forma, foram feitas as adequações necessárias ao projeto do ponto de vista energético, especificamente nos sistemas de iluminação e refrigeração artificial, visando tanto a classificação máxima de acordo com o RTQ-C como também a economia de energia e consequentemente, a redução de custos. Assim sendo, serão apresentadas também propostas de inclusão de alternativas energéticas para o edifício, visando uma eficiência energética ainda maior, bem como análises de viabilidade econômica e simulações energéticas das alterações propostas ao projeto da edificação, através dos softwares RetScreen e EnergyPlus. / This dissertation presents the analysis of energy efficiency of the Ceamazon building, a research laboratory bounded to the Federal University of Pará. For this study it was utilized the prescriptive method of the “Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Comerciais, de Serviços e Públicas – RTQ-C”. RTQ-C’s energy analysis involves three distinct parameters: the building envelope, the artificial illumination system and the air-conditioning system. The study of the characteristics of each one of these systems provides material for the necessary calculations of the method, which will result in a numeric equivalent for each one, representing the efficiency of each system. This dissertation’s analysis was done mainly at the artificial illumination system and the air-conditioning system, since one previous analysis of the building’s envelope had already collected good results. The primary goal of this dissertation was to fit the building studied in the level A of energy efficiency proposed by the regulation. Thus, adjustments were made to the project from the energetic point of view, specifically on the artificial illumination and air-conditioning systems, aiming not only the maximum classification according to RTQ-C but also energy savings and the consequent reduction of costs. Therefore, proposals of inclusion of energetic alternatives to the building will also be presented, aiming at a higher energy efficiency, as well as economic viability analysis and energetic simulations of the alterations proposed to the building project, utilizing the softwares RetScreen and EnergyPlus.
10

Estudo de casos sobre a inércia térmica de edificações na cidade de São Carlos. / Case study of buildings thermal inertia in Sao Carlos, SP.

Dornelles, Kelen Almeida 20 April 2004 (has links)
Made available in DSpace on 2016-06-02T20:09:14Z (GMT). No. of bitstreams: 1 DissKAD.pdf: 1431161 bytes, checksum: 35e43177014f0202b80650427d7d6613 (MD5) Previous issue date: 2004-04-20 / Financiadora de Estudos e Projetos / In this work, it was investigated the use of thermal inertia in buildings located in Sao Carlos city, SP, which presents semi-humid climate. This research aims to verify the hypothesis that the use of thermal inertia in buildings submitted to the specific climate of Sao Carlos allows to optimize the thermal performance of buildings and to reduce waste of energy to restore indoor thermal comfort. From data obtained by monitoring of seven different buildings, the thermal performance of each one was analyzed when they are submitted to typical simmer and winter conditions. To these seasons, adopting a reference day , it was estimated the heating and cooling requirement to restore the indoor comfort conditions. Besides the analyses for winter and summer seasons, it was estimated the indoor cooling and heating requirement along all moths of the year. Through this analyze, it was possible to verify the real influences of thermal inertia on the indoor comfort conditions. The results indicates that only the use of thermal inertia is insufficient to provide indoor thermal comfort conditions for buildings submitted to the specific climates of Sao Carlos. It is suggested to mach the use of thermal inertia with others passive strategies, in such a way to optimize the thermal performance of buildings. / Neste trabalho, investigou-se o uso da inércia térmica em edificações localizadas na cidade de São Carlos, SP, cujo clima pode se caracterizado como semi-úmido. O objetivo desta pesquisa foi verificar a hipótese de que a utilização da inércia térmica, em edificações submetidas ao clima específico da cidade, permite otimizar o desempenho térmico de edificações e reduzir a necessidade de sistemas artificiais de climatização para restabelece o conforto nos ambientes. Como base nos dados obtidos no monitoramento de ambientes de sete diferentes edificações, analisou-se o desempenho térmico de cada ambiente frente a condições típicas de inverno e verão. Para estes dois períodos, adotando-se um "dia de referência", fez-se o cálculo do desconforto por frio ou calor acumulado ao longo deste dia e se estimou a necessidade de aquecimento e refrigeração, para restabelecer o conforto térmico nos ambientes. Além das análises para inverno e verão, também se estimou a necessidade de aquecimento e refrigeração dos ambientes ao longo de todos os meses do ano. Esta análise permitiu verificar as reais influências da inércia térmica sobre as condições de conforto em edificações, as quais estão submetidas ao clima da cidade de São Carlos. As diversas formas de análise demonstram que apenas a utilização da inércia térmica não é suficiente para oferecer condições de conforto térmico nos ambientes, quando submetidos ao clima específico da cidade. Sugere-se que a utilização da inércia térmica seja combinada com outras estratégias de condicionamento passivo, de tal forma a otimizar o desempenho térmico das edificações.

Page generated in 0.1292 seconds