• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 10
  • 10
  • 10
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Spatial-Temporal Statistical Modeling of Treated Drinking Water Usage

Arandia, Ernesto 16 September 2013 (has links)
No description available.
2

Analysis Of Conventional Low Voltage Power Line Communication Methods For Automatic Meter Reading And The Classification And Experimental Verification Of Noise Types For Low Voltage Power Line Communication Network

Danisman, Batuhan 01 February 2009 (has links) (PDF)
In this thesis, the conventional low voltage power line communication methods is investigated in the axis of automated meter reading applications and the classification and experimental verification of common noise types for low voltage power line communication network. The investigated system provides the real time transmission of electricity consumption data recorded by electricity meters, initially to a local computer via a low voltage line through a low speed PLC (Power Line Carrier) environment and subsequently to a corporate network through a high speed data transmission medium. The automated meter system provides a more effective tracking and data acquisition, a more detailed and vigorous knowledge about consumer behavior for subscriber assessment in electricity distribution in association with a brand new management and system supervision concept in electricity distribution control and management technology. The theoretical studies are experimentally verified for the Turkish low voltage power infrastructure through laboratory experiments performed in METU Electrical and Electronics Engineering Department, Electrical Machines and Drives Laboratory and R&amp / D Laboratories of MAKEL facilities in Hadimk&ouml / y. The single phase voltage of the mains line between the phase and neutral is monitored to exhibit the disturbing effects of various noise sources. The resulting voltage spectrum is logged by using digital data acquisition devices in time and frequency domain. The waveforms are converted to frequency domain using the Fast Fourier Transform (FFT) functions of the MATLAB. The experimental results are compared to the theoretical findings obtained through literature survey.
3

Monitoring energy performance in local authority buildings

Stuart, Graeme January 2011 (has links)
Energy management has been an important function of organisations since the oil crisis of the mid 1970’s led to hugely increased costs of energy. Although the financial costs of energy are still important, the growing recognition of the environmental costs of fossil-fuel energy is becoming more important. Legislation is also a key driver. The UK has set an ambitious greenhouse gas (GHG) reduction target of 80% of 1990 levels by 2050 in response to a strong international commitment to reduce GHG emissions globally. This work is concerned with the management of energy consumption in buildings through the analysis of energy consumption data. Buildings are a key source of emissions with a wide range of energy-consuming equipment, such as photocopiers or refrigerators, boilers, air-conditioning plant and lighting, delivering services to the building occupants. Energy wastage can be identified through an understanding of consumption patterns and in particular, of changes in these patterns over time. Changes in consumption patterns may have any number of causes; a fault in heating controls; a boiler or lighting replacement scheme; or a change in working practice entirely unrelated to energy management. Standard data analysis techniques such as degree-day modelling and CUSUM provide a means to measure and monitor consumption patterns. These techniques were designed for use with monthly billing data. Modern energy metering systems automatically generate data at half-hourly or better resolution. Standard techniques are not designed to capture the detailed information contained in this comparatively high-resolution data. The introduction of automated metering also introduces the need for automated analysis. This work assumes that consumption patterns are generally consistent in the short-term but will inevitably change. A novel statistical method is developed which builds automated event detection into a novel consumption modelling algorithm. Understanding these changes to consumption patterns is critical to energy management. Leicester City Council has provided half-hourly data from over 300 buildings covering up to seven years of consumption (a total of nearly 50 million meter readings). Automatic event detection pinpoints and quantifies over 5,000 statistically significant events in the Leicester dataset. It is shown that the total impact of these events is a decrease in overall consumption. Viewing consumption patterns in this way allows for a new, event-oriented approach to energy management where large datasets are automatically and rapidly analysed to produce summary meta-data describing their salient features. These event-oriented meta-data can be used to navigate the raw data event by event and are highly complementary to strategic energy management.
4

Mise en place d'un modèle de fuite multi-états en secteur hydraulique partiellement instrumenté / Mastering losses on drinking water network

Claudio, Karim 19 December 2014 (has links)
L’évolution de l’équipement des réseaux d’eau potable a considérablement amélioré le pilotage de ces derniers. Le telérelevé des compteurs d’eau est sans doute la technologie qui a créé la plus grande avancée ces dernières années dans la gestion de l’eau, tant pour l’opérateur que pour l’usager. Cette technologie a permis de passer d’une information le plus souvent annuelle sur les consommations (suite à la relève manuelle des compteurs d’eau) à une information infra-journalière. Mais le télérelevé, aussi performant soit-il, a un inconvénient : son coût. L’instrumentation complète d’un réseau engendre des investissements que certains opérateurs ne peuvent se permettre. Ainsi la création d’un échantillon de compteurs à équiper permet d’estimer la consommation totale d’un réseau tout en minimisant les coûts d’investissement. Cet échantillon doit être construit de façon intelligente de sorte que l’imprécision liée à l’estimation ne nuise pas à l’évaluation des consommations. Une connaissance précise sur les consommations d’eau permet de quantifier les volumes perdus en réseau. Mais, même dans le cas d’une évaluation exacte des pertes, cela ne peut pas suffire à éliminer toutes les fuites sur le réseau. En effet, si le réseau de distribution d’eau potable est majoritairement enterré, donc invisible, il en va de même pour les fuites. Une fraction des fuites est invisible et même indétectable par les techniques actuelles de recherche de fuites, et donc irréparable. La construction d’un modèle de fuite multi-états permet de décomposer le débit de fuite suivant les différents stades d’apparition d’une fuite : invisible et indétectable, invisible mais détectable par la recherche de fuite et enfin visible en surface. Ce modèle, de type semi-markovien, prend en compte les contraintes opérationnelles, notamment le fait que nous disposons de données de panel. La décomposition du débit de fuite permet de fait une meilleure gestion du réseau en ciblant et adaptant les actions de lutte contre les fuites à mettre en place en fonction de l’état de dégradation du réseau. / The evolution of equipment on drinking water networks has considerably bettered the monitoring of these lasts. Automatic meter reading (AMR) is clearly the technology which has brought the major progress these last years in water management, as for the operator and the end-users. This technology has allowed passing from an annual information on water consumption (thanks to the manual meter reading) toan infra-daily information. But as efficient as AMR can be, it has one main inconvenient : its cost. A complete network instrumentation generates capital expenditures that some operators can’t allowed themselves. The constitution of a sample of meters to equip enables then to estimate the network total consumption while minimizing the investments. This sample has to be built smartly so the inaccuracy of the estimator shouldn’t be harmful to the consumption estimation. A precise knowledge on water consumption allowsquantifying the water lost volumes on the network. But even an exact assessment of losses is still not enough to eliminate all the leaks on the network. Indeed, if the water distribution network is buried, and so invisible, so do the leaks. A fraction of leaks are invisible and even undetectable by the current technologies of leakage control, and so these leaks are un-reparable. The construction of a multi-state model enables us to decompose the leakage flow according to the different stages of appearance of a leak : invisible and undetectable, invisible but detectable with leakage control and finally detectable. This semi-Markovian model takes into account operational constrains, in particular the fact that we dispose of panel data. The leakage flow decomposition allows a better network monitoring but targeting and adapting the action of leakage reduction to set up according to the degradation state of the network.
5

New opportunities provided by the Swedish electricity meter reform

Wallin, Fredrik January 2010 (has links)
The reduction of the impact of energy consumption is a priority issue and a major challenge that concerns every country in the world. This is a complex task that needs to be tackled from several angles in the search for areas where optimizations and savings can be made. In Sweden an electricity meter reading reform was fully implemented by 1st July 2009, including 5.2 million customers, and this created new set of circumstances in the Swedish electricity market. The main purpose of this thesis work has been to investigate the possibilities of increasing the use of remote meter readings. Two research questions have been: “How can the electricity market benefit from remote collected meter readings?” and “Where do barriers appear when utilizing meter readings?”. The work started in 2000/2001 to study Internet based applications that visualize electricity consumption patterns. Over these years the daily internet users have increased from approximately 40 % to 73 % and new markets for web-based applications have evolved. These solutions can be important in the forthcoming years as energy portals that hold new energy services. Experiences from new installations indicate that at least interested customers do submit information concerning building and household properties through internet. Still, it is challenging to enable the majority of customers to take part in these new solutions. It may therefore be important to remind customers on a regular basis in order maintain the frequency using the application and to make it habitual. Further the introduction of demand-based pricing allows electricity distribution utilities to achieve a stronger correlation between peak loads in the distribution network area and their revenues.
6

Προσδιορισμός της απόδοσης αγωγών υψηλής τάσης για τη χρήση PowerLine Communication (PLC)

Μουστάκα, Μαρία, Σταμούλη, Αλεξία 16 June 2011 (has links)
Ο στόχος της διπλωματικής αυτής είναι η περιγραφή της αναδυόμενης τεχνολογίας PLC (PowerLine Communication). Η τεχνολογία αυτή με τη χρήση του πανταχού παρόντος ηλεκτρικού δικτύου προσφέρει ακόμα και σε απομακρυσμένους χρήστες πληθώρα ευρυζωνικών υπηρεσιών και πρόσβαση στο διαδίκτυο, αποτελώντας μια ανταγωνιστική επιλογή τρόπου επικοινωνίας. Για την κατανόηση της PLC τεχνολογίας αρχικά κρίνουμε απαραίτητη την λεπτομερή περιγραφή της δομής του ηλεκτρικού δικτύου, του εξοπλισμού που απαιτείται για την εφαρμογή της και των αρχιτεκτονικών της. Στη συνέχεια γίνεται αναφορά στα προβλήματα που παρουσιάζονται και χρήζουν αντιμετώπισης. Επιπρόσθετα, γίνεται σύντομη παρουσίαση των εναλλακτικών υπηρεσιών και σύγκριση των PLC με αυτές. Η μετάδοση μέσω ηλεκτροφόρων καλωδίων προσφέρει ένα μεγάλο εύρος ζώνης, παρέχοντας μία γκάμα πολυάριθμων υπηρεσιών, όπως το έξυπνο σπίτι ή το AMR (Automatic Meter Reading) για τη διευκόλυνση τόσο των οικιακών χρηστών όσο και των επιχειρησιακών. Η χρήση των γραμμών ηλεκτρικής ενέργειας ως τηλεπικοινωνιακό κανάλι απαιτεί την εφαρμογή των κατάλληλων τεχνικών πρόσβασης. Οι πιο διαδεδομένες τεχνικές είναι οι FDMA (Frequency Division Multiple Access), TDMA (Time Division Multiple Access) και CDMA (Code Division Multiple Access) . Η παρούσα διπλωματική επικεντρώθηκε στην TDMA και την FDMA με διαμόρφωση σήματος OFDM (Orthogonal Frequency Division Multiplexing) η οποία ονομάζεται OFDMA (Orthogonal Frequency Division Multiple Access). Πραγματοποιήθηκαν εξομοιώσεις σε Matlab διάφορων αλγορίθμων αναλογικής δικαιοσύνης με τεχνική OFDMA και ταυτόχρονη εξομοίωση της TDMA. Στόχος είναι να συγκρίνουμε τους αλγόριθμους αυτούς ως προς το συνολικό ρυθμό μετάδοσης και τη δικαιοσύνη κατανομής των πόρων στους χρήστες. Από τη σύγκριση αυτή προκύπτει ότι η τεχνική TDMA αποδίδει λιγότερο, ενώ από τους υπόλοιπους αλγόριθμους τα καλύτερα αποτελέσματα επιφέρει ο αλγόριθμος των Bill et al., με ισορροπία του συνολικού ρυθμού μετάδοσης και της επιθυμητής δικαιοσύνης. / Main goal of this diploma thesis is the description of the up and coming PLC (PowerLine Communication) technology. This technology offers access to the web and to several broadband services to even distant and isolated users, by exploiting the power line grid, widely spread to nearly all surface land sites, consisting this way a competitive communication alternative. For a better comprehension of the PLC technology, this work starts with a detailed description of the power line grid, the several PLC technology architectures and the necessary equipment for their application. Following this work, there is a reference to any possible problems that need to be overcome and a short comparative presentation of the PLC technology versus other alternatives to it. The data transmission over electricity lines offers a wide bandwidth and thus it may support a variety of applications, as the smart home and AMR (Automatic Meter Reading) for the proper service of either domestic or industrial users. The use of electricity power lines as a communication channel necessitates the application of multiple access Strategies as FDMA (Frequency Division Multiple Access), TDMA (Time Division Multiple Access) and CDMA (Code Division Multiple Access), which are currently the most popular. This thesis is focused on TDMA and FDMA with OFDM signal modulation. This technique is called OFDMA (Orthogonal Frequency Division Multiple Access). Several proportional rate constraints algorithms were simulated in Matlab applying both OFDMA and TDMA strategies in order to compare these algorithms in terms of the maximized total throughput and the fair allocation of resources to the end users (fairness). From this comparison it comes up that TDMA technique is less efficient, whereas from the other algorithms the most efficient is the one of Bill et al., that offers a good balance between total throughput and fairness.
7

Investeringsbedömning av mätinsamlingssystem : för Mälarenergi Elnät AB / Capital budgeting of Automatic Meter Reading Systems : for Mälarenergi Elnät AB

Bengtsson, Gustav, Einås, Daniel January 2004 (has links)
<p>Detta examensarbete har genomförts vid Mälarenergi Elnät AB i Västerås. Undersökningen föranleddes av regeringsbeslutet om att elmätare måste avläsas en gång per månad från 2009. Konsekvensen för Mälarenergi är att de måste investera i ett automatiskt mätinsamlingssystem. Syftet med projektet har varit att skapa en generell investeringsmodell för att ekonomiskt utvärdera ett antal mätinsamlingssystem. I rapporten har Milabs, Seneas, Enermets, HM Powers, Iprobes samt Techems och Viterras system analyserats. Resultaten från investeringskalkylen visar att Mälarenergi kommer att göra en förlust på 5-8 MSEK/år under hela projektets livslängd (15 år). Den största delen av investeringen utgörs av hårdvarukostnader (50 %), medan drift- och underhållskostnader samt logistikkostnader utgör 20 % respektive 25 %. Mälarenergi Elnät bör budgetera 1 500-1 950 SEK/mätpunkt för projektet, beroende på systemval. En känslighetsanalys visar att driftskostnad och livslängd är avgörande faktorer, vilket medför att det är viktigare att satsa på ett robust och säkert system än det billigaste.</p>
8

Investeringsbedömning av mätinsamlingssystem : för Mälarenergi Elnät AB / Capital budgeting of Automatic Meter Reading Systems : for Mälarenergi Elnät AB

Bengtsson, Gustav, Einås, Daniel January 2004 (has links)
Detta examensarbete har genomförts vid Mälarenergi Elnät AB i Västerås. Undersökningen föranleddes av regeringsbeslutet om att elmätare måste avläsas en gång per månad från 2009. Konsekvensen för Mälarenergi är att de måste investera i ett automatiskt mätinsamlingssystem. Syftet med projektet har varit att skapa en generell investeringsmodell för att ekonomiskt utvärdera ett antal mätinsamlingssystem. I rapporten har Milabs, Seneas, Enermets, HM Powers, Iprobes samt Techems och Viterras system analyserats. Resultaten från investeringskalkylen visar att Mälarenergi kommer att göra en förlust på 5-8 MSEK/år under hela projektets livslängd (15 år). Den största delen av investeringen utgörs av hårdvarukostnader (50 %), medan drift- och underhållskostnader samt logistikkostnader utgör 20 % respektive 25 %. Mälarenergi Elnät bör budgetera 1 500-1 950 SEK/mätpunkt för projektet, beroende på systemval. En känslighetsanalys visar att driftskostnad och livslängd är avgörande faktorer, vilket medför att det är viktigare att satsa på ett robust och säkert system än det billigaste.
9

Power line communications for the electrical utility: physical layer design and channel modeling

Aquilué de Pedro, Ricardo 16 July 2008 (has links)
El món de les comunicacions per la xarxa elèctrica (CXE) pot ser dividit en tres grans tipus: CXE en baix voltatge (CXE-BV), en mig voltatge (CXE-MV) i en alt voltatge (CXE-AV). En aquests últims anys, les CXE-BV han atret una gran expectació, ja que les seves capacitats han fet d'aquesta tecnologia una bona opció com alternativa pel bucle local d'accés i pel desplegament de xarxes d'àrea local, focalitzades aquestes últimes en l'entorn domèstic. A més, les CXE-BV inclouen un conjunt d'aplicacions de baixa velocitat orientades a l'operador, com la lectura automàtica de comptadors (LAC), distribució de càrrega, facturació dinàmica, etc. Per altra banda, les CXE-MV i CXE-AV, històricament lligades a tasques de telecontrol i teleprotecció, s'estan començant a considerar com un canal de comunicacions eficient i fiable. El desenvolupament de sistemes digitals i els esforços d'estandardització estan fent d'aquests canals un medi atractiu per a que els operadors elèctrics ofereixin serveis de comunicacions, ja que no necessiten invertir en infraestructura perquè la xarxa elèctrica ja està desplegada.En aquesta Tesi s'introduiran i es comentaran les particularitats de les tres xarxes elèctriques, després, es mostraran al lector les solucions tecnològiques existents pels canals de BV basats en la norma Europea CENELEC així com pels canals d'AV, mostrant que els sistemes actuals de LAC ofereixen una diversitat freqüencial molt baixa i que els mòdems CXE-AV estan ancorats en estendards antiquats.Aquest treball es mou per les tres topologies de la xarxa, particularment, en aplicacions orientades a la banda CENELEC, en mesura i modelat de canal, i en mesura i disseny del nivell físic per sistemes CXE-BV, CXE-MV i CXE-AV respectivament. Els sistemes actuals que exploten la banda CENELEC ofereixen mecanismes d'explotació de la diversitat freqüencial del canal molt limitats o nuls, donant lloc a una baixa robustesa en front a interferències i soroll de fons acolorit. Aquest treball proposa un esquema de modulació multiportadora que, mantenint una complexitat baixa, ofereix unes altes prestacions permetent un bon nivell d'explotació de la selectivitat freqüencial. Per al que a CXE-MV respecta, aquesta Tesi desenvolupa un model de canal determinístic-estadístic pels anells urbans de distribució de potència i, finalment, en sistemes CXE-AV, aquest treball proposa, basat en mesures de canal i proves de camp, un nivell físic de banda ampla capaç de incrementar la velocitat de comunicació mentre manté una baixa densitat espectral de potència limitant així la interferència a altres sistemes.PARAULES CLAU: Power line communications (PLC), low voltage (LV), medium voltage (MV), high voltage (HV), automatic meter reading (AMR), orthogonal frequency division multiplexing (OFDM), multicarrier spread spectrum (MC-SS), communication system design, channel measurements, channel modeling, scattering parameters. / El mundo de las comunicaciones por la red eléctrica (CRE) puede ser dividido en tres grandes tipos: CRE en bajo voltaje (CRE-BV), en medio voltaje (CRE-MV) y en alto voltaje (CRE-AV). En estos últimos años, las CRE-BV han atraído una gran expectación, ya que sus capacidades han hecho de esta tecnología una buena opción como alternativa para el bucle local de acceso y para el despliegue de redes de área local, focalizadas estas últimas en el entorno doméstico. Además, las CRE-BV incluyen un conjunto de aplicaciones de baja velocidad orientadas al operador como la lectura automática de contadores (LAC), distribución de carga, facturación dinámica, etc. Por otro lado, las CRE-MV y CRE-AV, históricamente ligadas a tareas de telecontrol y teleprotección, se están empezando a considerar como un canal de comunicaciones eficiente y fiable. El desarrollo de sistemas digitales y los esfuerzos de estandarización están haciendo de estos canales un medio atractivo para que los operadores eléctricos ofrezcan servicios de comunicaciones, ya que no necesitan invertir en infraestructura porque la red eléctrica ya está desplegada.En esta Tesis se introducirán y se comentarán las particularidades de las tres redes eléctricas, luego, se mostrarán al lector las soluciones tecnológicas existentes para los canales de BV basados en la norma Europea CENELEC así como para los canales de AV, mostrando que los sistemas actuales de LAC ofrecen una diversidad frecuencial muy baja y que los módems CRE-AV están anclados en estándares anticuados.Este trabajo se mueve por las tres topologías de red, particularmente, en aplicaciones orientadas a la banda CENELEC, en medida y modelado de canal, y en medida y diseño del nivel físico para sistemas CRE-BV, CRE-MV y CRE-AV respectivamente. Los sistemas actuales que explotan la banda CENELEC ofrecen mecanismos de explotación de la diversidad frecuencial del canal muy limitados o nulos, dando lugar a una escasa robustez frente a interferencias y ruido de fondo coloreado. Este trabajo propone un esquema de modulación multiportadora que, manteniendo una complejidad baja, ofrece unas altas prestaciones permitiendo un buen nivel de explotación de la selectividad frecuencial. Por lo que a CRE-MV respecta, esta Tesis desarrolla un modelo de canal determinístico-estadístico para los anillos urbanos de distribución de potencia y, finalmente, en sistemas de CRE-AV, este trabajo propone, basado en medidas de canal y pruebas de campo, un nivel físico de banda ancha capaz de incrementar la velocidad de comunicación mientras mantiene una baja densidad espectral de potencia limitando así la interferencia a otros sistemas.PALABRAS CLAVE: Power line communications (PLC), low voltage (LV), medium voltage (MV), high voltage (HV), automatic meter reading (AMR), orthogonal frequency division multiplexing (OFDM), multicarrier spread spectrum (MC-SS), communication system design, channel measurements, channel modeling, scattering parameters. / The world of Power line communications (PLC) can be divided into three main types: low voltage PLC (LV-PLC), medium voltage PLC (MV-PLC) and high voltage PLC (HV-PLC). These last years, LV-PLC has attracted a great expectation since its wideband capabilities has made this technology a suitable choice for last-mile access and in-home communications. Moreover, LV-PLC also includes a utility oriented low frequency and low speed applications, such as automatic meter reading (AMR), load distribution, dynamic billing and so on. On the other hand, MV-PLC and HV-PLC, historically oriented to teleprotection and telecontrol tasks, are being considered as a reliable communication channel. The development of digital equipment and the standardization efforts are making those channels an attractive medium for electrical utilities telecommunications services, since the network, as well as in LV-PLC, is already deployed. In this PhD dissertation, the three different PLC topologies are reviewed and the different communications techniques in such channels exposed. Then, a deep technological review of existing AMR solutions for the European CENELEC band, as well as HV-PLC systems is given, showing that existing AMR systems deliver low frequency diversity and HV-PLC systems are anchored in old fashioned standards.This work walks around the three topologies, specifically, CENELEC band utility oriented applications, channel measurement and modeling and channel measurement and physical layer design, regarding LV-PLC, MV-PLC and HV-PLC respectively. Existing CENELEC compliant systems deliver low or none frequency diversity mechanisms, yielding in a low robustness against colored noise and interference. This work propose a multicarrier based physical layer approach that, while keeping the complexity low, delivers high performance allowing a great level of frequency diversity. Focusing on MV-PLC, a hybrid deterministic-statistical channel model for urban underground rings is developed and, finally, in HV-PLC systems, this work proposes, based on measurements and field tests, a wideband physical layer in order to increase data rate while keeping low both the power spectral density and possible interference to other systems.KEYWORDS: Power line communications (PLC), low voltage (LV), medium voltage (MV), high voltage (HV), automatic meter reading (AMR), orthogonal frequency division multiplexing (OFDM), multicarrier spread spectrum (MC-SS), communication system design, channel measurements, channel modeling, scattering parameters.
10

Vzdálené měřicí systémy a jejich praktické využití / Remote measuring systems and its utilization in practise

Kukla, Zdeněk January 2008 (has links)
This master’s thesis is dealing with remote measuring systems and their utilization in power engineering. In the first part there are described requirements on an autonomous measuring system and description of AMM and AMR systems. Communicating and data flows working on accurately defined communicating layers are also depicted in this part. The attention is devoted to the possibility of data processing and functions of devices offered by these attributes. In the following part there are described reasons for utilization of remote measuring systems in power engineering and the main advantages of connection of more devices into one unit. After finding of required parametres and functions of systems, a suggestion of terminal device is created in the same way. The suggestion is described in the measuring part with A/D converter, processing in microprocessor, measuring and evaluating alogorithms and attributes of communication of bus used. The last part is devoted to utilization of remote analysis in small power stations in dispersed production. Formation of deformation of voltage, harmonic analysis of signal and its application for data processing are described there. Described analysis was tested on data acquired from a cogeneration unit.

Page generated in 0.1317 seconds