• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 1
  • 1
  • Tagged with
  • 24
  • 12
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sensores magnetorresistivos para aplicações de biomagnetismo / Sensores Magnetoresistivos para Aplicações de Biomagnetismo

Silva, Fabiano Miranda da 31 March 2009 (has links)
O laboratório de biomagnetismo tem realizado com sucesso estudos da motilidade gastrointestinal medindo tempos de trânsito e de esvaziamento de diferentes segmentos do trato gastrointestinal. Nesse estudo tanto a magnetização remanente como a susceptibilidade magnética de diferentes regiões do trato gastrointestinal são medidas. Os sensores magnetoresistivos serão utilizados para estudo de marcadores ferromagnéticos ou pequenos imãs (aproximados por dipolos magnéticos) in vitro, que possibilitará em trabalhos futuros serem utilizados no estudo de marcadores magnéticos no trato gastrintestinal. Neste trabalho testaremos a idéia de um concentrador de fluxo magnético, que seja capaz de aumentar a densidade de linhas de campo magnético na região próxima ao sensor. Desenvolvemos a instrumentação de uma ponte de prova que contivesse um único sensor magnetorresistivo ligado a uma placa de condicionamento dos sinais. A ponta de prova foi utilizada para teste da eficiência dos concentradores de fluxo magnético e para fazermos varredura de regiões com o auxilio de uma mesa xy, com a finalidade de construir mapas densidade de campo magnético de dipolos estáticos no tempo. Terminaremos o trabalho mostrando a possibilidade construir imagens de dipolos que se movem, desenvolvendo um sistema de aquisição dos sinais dos sensores em tempo real, será utilizando uma matriz com dezesseis sensores magnetorresistivos os sinais serão tratados e a imagem construída pelo método de interpolação matemática, este sistema abre a possibilidade para aplicação em trabalhos futuros no estudo da motilidade gastrointestinal medindo tempos de transito usando a técnica de susceptibilidade magnética marcadores ferromagnéticos e também de dipolos permanentes sem a necessidade de campo externo aplicado. / The biomagnetism laboratory has successively performing studies of gastrointestinal (GI) motility by the measurement of transit times and emptying times of different segments of the GI tract. In this kind of work the remanent magnetization as well as the magnetic susceptibility are measured in different regions of the GI tract. Magnetoresistive (MR) sensors are used to study ferromagnetic markers along the GI tract. Recently this potential was demonstrated in a doctoral thesis done at this group, where image formation of magnetic particles was studied. In this work it became clear that the small region sampled by the MR sensors and the necessity to increase the area sampled by each sensor. One of the goals of this work is to develop a magnetic flux concentrator that could be able to focus the magnetic field of an area on the order of a few centimeters in the MR sensor, usually much smaller. The signal conditioning, acquisition and processing will also be developed in this work. As can be verified it is possible to use the MR sensors with advantages in relation to other sensors in some specific applications.
2

Sensores magnetorresistivos para aplicações de biomagnetismo / Sensores Magnetoresistivos para Aplicações de Biomagnetismo

Fabiano Miranda da Silva 31 March 2009 (has links)
O laboratório de biomagnetismo tem realizado com sucesso estudos da motilidade gastrointestinal medindo tempos de trânsito e de esvaziamento de diferentes segmentos do trato gastrointestinal. Nesse estudo tanto a magnetização remanente como a susceptibilidade magnética de diferentes regiões do trato gastrointestinal são medidas. Os sensores magnetoresistivos serão utilizados para estudo de marcadores ferromagnéticos ou pequenos imãs (aproximados por dipolos magnéticos) in vitro, que possibilitará em trabalhos futuros serem utilizados no estudo de marcadores magnéticos no trato gastrintestinal. Neste trabalho testaremos a idéia de um concentrador de fluxo magnético, que seja capaz de aumentar a densidade de linhas de campo magnético na região próxima ao sensor. Desenvolvemos a instrumentação de uma ponte de prova que contivesse um único sensor magnetorresistivo ligado a uma placa de condicionamento dos sinais. A ponta de prova foi utilizada para teste da eficiência dos concentradores de fluxo magnético e para fazermos varredura de regiões com o auxilio de uma mesa xy, com a finalidade de construir mapas densidade de campo magnético de dipolos estáticos no tempo. Terminaremos o trabalho mostrando a possibilidade construir imagens de dipolos que se movem, desenvolvendo um sistema de aquisição dos sinais dos sensores em tempo real, será utilizando uma matriz com dezesseis sensores magnetorresistivos os sinais serão tratados e a imagem construída pelo método de interpolação matemática, este sistema abre a possibilidade para aplicação em trabalhos futuros no estudo da motilidade gastrointestinal medindo tempos de transito usando a técnica de susceptibilidade magnética marcadores ferromagnéticos e também de dipolos permanentes sem a necessidade de campo externo aplicado. / The biomagnetism laboratory has successively performing studies of gastrointestinal (GI) motility by the measurement of transit times and emptying times of different segments of the GI tract. In this kind of work the remanent magnetization as well as the magnetic susceptibility are measured in different regions of the GI tract. Magnetoresistive (MR) sensors are used to study ferromagnetic markers along the GI tract. Recently this potential was demonstrated in a doctoral thesis done at this group, where image formation of magnetic particles was studied. In this work it became clear that the small region sampled by the MR sensors and the necessity to increase the area sampled by each sensor. One of the goals of this work is to develop a magnetic flux concentrator that could be able to focus the magnetic field of an area on the order of a few centimeters in the MR sensor, usually much smaller. The signal conditioning, acquisition and processing will also be developed in this work. As can be verified it is possible to use the MR sensors with advantages in relation to other sensors in some specific applications.
3

Gradiômetros supercondutores acoplados a SQUIDs e sua aplicação em biomagnetismo. / SQUID superconducting gradiometers applied to biomagnetism.

Bruno, Antonio Carlos Oliveira 13 September 1990 (has links)
O objetivo desta tese foi o estudo da detecção de campos magnéticos fracos através da utilização de gradiômetros supercondutores acoplados à SQUIDs e sua aplicação ao biomagnetismo. Um novo modelo teórico para descrição do gradiômetro foi desenvolvido com a obtenção da sua função de transferência espacial. Através desta função de transferência a atuação do gradiômetro sobre os sinais detectados pode ser quantificada. Além disso, foi desenvolvido para a medida experimental da função de transferência, onde as imperfeições no processo de construção do sensor podem ser medidas e avaliadas. Foi proposta uma nova terminologia para descrição do gradiômetro ao invés de sua descrição física. Nesta terminologia, o gradiômetro ficará especificado pelo seu roll off, freqüência de corte espacial e ganho máximo. Também foi generalizado o método para projeto de gradiômetros onde novas configurações podem ser construídas e testadas. A partir da obtenção desta função de transferência um método para calibração tesla /volt do sistema foi desenvolvido, com uma precisão até então não alcançada por outros métodos e perfeitamente apropriado para utilização em sistemas multicanais. Finalmente foi desenvolvido um algorítimo de desconvolução para, a partir de sinais detectados com gradiômetros planares, recuperar o sinal original como ele tivesse sido detectado somente por uma bobina. Este algorítmo também pode ser utilizado para auxílio no projeto de arrays destes gradiômetros. / The objective of this thesis was to study the detection of weak magnetic fields through the use of superconducting gradiometers coupled to SQUIDs and its application to biomagnetism. A new theoretical model for the specification of the gradiometer was developed by obtaining its spatial transfer function. Through the transfer function the signal detected by the gradiometer can be quantified. Besides, a procedure was developed to experimentally measure the spatial transfer, where the imperfections in the construction process of the sensor can be measured and evaluated. A new terminology was proposed for specification of the gradiometer instead of his physical description. Using this terminology, the gradiometer will be specified by its roll off, spatial cutoff frequency and maximum gain. Also the method was generalized for design of gradiometers where new configurations can be built and tested. From the transfer function a method for tesla/volt calibration of the system was developed. Finally a deconvolution algorithm was developed, that from signals detected by the gradiometer the original signal can be recovered. This algorithm also can be used in the design of gradiometer arrays.
4

Modelo de estudo da motilidade gastrointestinal utilizando a eletromiografia (EMG) e a biosusceptometria AC (BAC) em ratos normais, desnutridos e diabéticos induzidas pela aloxana

Marques, Rozemeire Garcia [UNESP] 22 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-22Bitstream added on 2014-06-13T20:21:54Z : No. of bitstreams: 1 marques_rg_dr_botfm.pdf: 1840214 bytes, checksum: cedd11ae72463d2d0bf0333d2d17eee2 (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo desse trabalho foi desenvolver um modelo experimental de análise da motilidade do Trato gastrointestinal (TGI) com potencialidades para caracterizar a atividade elétrica e mecânica do estômago e do cólon de ratos normais, diabéticos induzidos pela aloxana e desnutridos, por restrição alimentar, utilizando a eletromiografia (EMG) e a biosusceptometria AC (BAC). Ratos adultos, machos, da linhagem Wistar foram distribuídos, por sorteio, em três grupos experimentais pareados: Grupo controle - constituído de 20 animais normais, sadios, não diabéticos; Grupo diabético - constituído de 20 animais diabéticos induzidos pela aloxana, não tratados; Grupo desnutrido - constituído de 20 animais desnutridos por restrição alimentar. Cada um destes três grupos experimentais foi subdividido, por sorteio, em dois subgrupos de ratos, compostos por 10 animais cada um, para serem avaliados e sacrificados em 2 momentos distintos do experimento, 1 mês e 6 meses de seguimento. As cirurgias de implantação do conjunto eletrodo/marcador magnético na serosa gástrica e do cólon, para obtenção dos registros elétricos e mecânicos, foram realizadas respectivamente após 1 mês e 6 meses de seguimento normal, diabético e de desnutrição. Os parâmetros avaliados foram: 1) Clínicos (peso corporal, ingestão hídrica, ingestão alimentar e diurese); 2) Laboratoriais (glicemia de jejum, hemoglobina glicosilada, insulina plasmática, proteínas totais e albumina); 3) Análise da atividade elétrica e mecânica do estômago e do cólon através da EMG e da BAC. 1) a média da frequência de contração gástrica não foi alterada significantemente entre os animais normais, desnutridos e diabéticos, tanto nas avaliações feitas pela BAC, como pela EMG; 2) a regularidade no sinal da atividade de contração gástrica em ratos diabéticos, no 1º mês de seguimento, e principalmente... / The objective of this study was to develop an experimental model for analyzing the motility of the gastrointestinal tract (TGI) with potential to characterize the electrical and mechanical activity of stomach and colon of normal rats, alloxan induced diabetic and undernourished by food restriction, using electromyography (EMG) and biosusceptometry AC (BAC). Adult male rats, lineage Wistar, were divided by sorting into three groups matched: Control group - consisting of 20 normal animals were healthy, nondiabetic; diabetic group - consisting of 20 rats with alloxan induced diabetic untreated; Malnourished group - consisting of 20 malnourished rats by dietary restriction. Each of these three groups was divided by sort into two subgroups of rats, consisting of 10 animals each to be evaluated and sacrificed at two different times of the experiment, 1 month and 6 months of follow up. A surgical implantation of electrode assembly / magnetic marker in gastric serosa and colonic to obtain electric and mechanical records , were held respectively at 1 month and 6 months of normal follow-up , diabetic and malnutrition. The parameters were evaluated: 1) Clinical (body weight, water intake, food intake and urine output), 2) Laboratory (fasting glucose, glycated hemoglobin, plasma insulin, total protein and albumin), 3) Analysis of electrical and mechanical activity of stomach and colon by EMG and the BAC. 1) the average frequency of gastric contraction was not altered significantly between the normal animals, malnourished and diabetic, both the assessments made by the BAC, as the EMG, 2) the regularity of signal activity of gastric contraction in diabetic rats, at 1 month follow-up, especially at 6 months, was greatly altered compared to normal rats and malnourished, with both techniques, 3) An increased the mean frequency and amplitude of contraction in the postprandial state, compared... (Complete abstract click electronic access below)
5

Gradiômetros supercondutores acoplados a SQUIDs e sua aplicação em biomagnetismo. / SQUID superconducting gradiometers applied to biomagnetism.

Antonio Carlos Oliveira Bruno 13 September 1990 (has links)
O objetivo desta tese foi o estudo da detecção de campos magnéticos fracos através da utilização de gradiômetros supercondutores acoplados à SQUIDs e sua aplicação ao biomagnetismo. Um novo modelo teórico para descrição do gradiômetro foi desenvolvido com a obtenção da sua função de transferência espacial. Através desta função de transferência a atuação do gradiômetro sobre os sinais detectados pode ser quantificada. Além disso, foi desenvolvido para a medida experimental da função de transferência, onde as imperfeições no processo de construção do sensor podem ser medidas e avaliadas. Foi proposta uma nova terminologia para descrição do gradiômetro ao invés de sua descrição física. Nesta terminologia, o gradiômetro ficará especificado pelo seu roll off, freqüência de corte espacial e ganho máximo. Também foi generalizado o método para projeto de gradiômetros onde novas configurações podem ser construídas e testadas. A partir da obtenção desta função de transferência um método para calibração tesla /volt do sistema foi desenvolvido, com uma precisão até então não alcançada por outros métodos e perfeitamente apropriado para utilização em sistemas multicanais. Finalmente foi desenvolvido um algorítimo de desconvolução para, a partir de sinais detectados com gradiômetros planares, recuperar o sinal original como ele tivesse sido detectado somente por uma bobina. Este algorítmo também pode ser utilizado para auxílio no projeto de arrays destes gradiômetros. / The objective of this thesis was to study the detection of weak magnetic fields through the use of superconducting gradiometers coupled to SQUIDs and its application to biomagnetism. A new theoretical model for the specification of the gradiometer was developed by obtaining its spatial transfer function. Through the transfer function the signal detected by the gradiometer can be quantified. Besides, a procedure was developed to experimentally measure the spatial transfer, where the imperfections in the construction process of the sensor can be measured and evaluated. A new terminology was proposed for specification of the gradiometer instead of his physical description. Using this terminology, the gradiometer will be specified by its roll off, spatial cutoff frequency and maximum gain. Also the method was generalized for design of gradiometers where new configurations can be built and tested. From the transfer function a method for tesla/volt calibration of the system was developed. Finally a deconvolution algorithm was developed, that from signals detected by the gradiometer the original signal can be recovered. This algorithm also can be used in the design of gradiometer arrays.
6

Estudos biomagnéticos em fisiologia gástrica / Biomagnetic studies of the gastric physiology

Miranda, Jose Ricardo de Arruda 21 November 1995 (has links)
Este trabalho interdisciplinar apresenta três novas aplicações de diferentes métodos biomagnéticos para estudar características físicas da motilidade gástrica humana. Empregou-se um biosusceptômetro AC para medir a atividade mecânica de contração gástrica através do acompanhamento temporal dos traçadores magnéticos previamente ingeridos com um alimento teste (80 ml de iogurte e 3 g de ferrita em pó). Os registros gráficos foram obtidos de forma bastante satisfatória, mostrando ser esse método uma alternativa viável para a detecção e seguimento temporal dessa atividade, em condições normais e sob o efeito de drogas. Através do processo de relaxação de partículas previamente magnetizadas no interior do estômago e com o auxílio de um magnetômetro de saturação de fluxo, estudou-se o processo de mistura de um alimento teste no estômago. Um pulso de campo magnético de aproximadamente 600 G é aplicado sobre a região gástrica do voluntário contendo o alimento teste (80 ml de iogurte e 3 g de magnetita em pó), e o campo remanente é medido e acompanhado no tempo. Os resultados preliminares indicam que esse método apresenta um grande potencial para um maior entendimento das características físicas da função de mistura do estômago e também da atividade de contração do estômago. Novos estudos sob condições variadas de alimentação e drogas podem fornecer subsídios para uma melhor interpretação desse processo. Utilizando-se um magnetômetro supercondutor (SQUID-DC) mediu-se a atividade elétrica gástrica obtendo-se bons traçados temporais na maioria das medidas. Os registros indicam que através desse sistema podem-se realizar experimentos no intuito de diferenciar as atividades elétricas e também observar seu comportamento frente a diferentes condições clínicas. Os dados obtidos nesse trabalho mostram ser este enfoque um valioso instrumento que pode contribuir para um melhor entendimento das características físicas da motilidade gástrica e também possibilitar novos estudos sobre o sistema gastrointestinal / This interdisciplinary work presents three new applications of different biomagnetic methods to study physical characteristics of human gastric motility. A biosusceptometer was used to measure the mechanical activity of gastric contraction through a time to time checking of the magnetic tracers previously ingested by a volunteer along with a test food (80 ml of yogurt and 3g of ferrite in powder). Results in graphical recording were very satisfactory, indicating this method as a possible alternative to detect and also follow up that gastric activity, besides allowing the evaluation of related activity under the effect of drugs. Through the observation of the relaxation of previously magnetized particles in the stomach, measured with a fluxgate magnetometer, the process of mixing of the test food in stomach was studied. A strong pulse of magnetic field (600G) is applied externally to the stomach region of the volunteer who have already ingested the mentioned food test, whereas the remanent field is measured and followed up in time. Preliminary results indicate that this method provides a good understanding of the physical characteristics of the mixture of food and also of the stomach contraction activity. New studies of different types of food and drugs may provide further information on the process. A superconductor magnetometer (SQUID-DC) was used to measure the gastric electrical activity, and good temporal tracers were obtained for the majority of measurements. Recordings were of satisfactory quality, indicating that through that system, experiments can be carried out in order to differentiate the electrical activities and also to observe its behavior for different clinical conditions. Results obtained in this thesis to measure the gastric electromagnetic activity, indicate this to be a valuable tool to understand the physical characteristics of gastric motility, as well as to open new ways for studying the gastrointestinal system
7

Tomografia por biosusceptometria de corrente alternada

Fonseca Filho, Paulo Roberto da [UNESP] 03 February 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-03Bitstream added on 2015-05-14T16:59:09Z : No. of bitstreams: 1 000822024_20160203.pdf: 74282 bytes, checksum: 81fcaba4dabd99298046b62189ca92be (MD5) Bitstreams deleted on 2016-02-03T15:35:12Z: 000822024_20160203.pdf,. Added 1 bitstream(s) on 2016-02-03T15:35:53Z : No. of bitstreams: 1 000822024.pdf: 798249 bytes, checksum: cf24aa6eedaa8b219d13e0e5cf032c2e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos / The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research
8

Utilização de magnetorresistores no desenvolvimento de novas técnicas para aplicações em gastroenterologia

Paixão, Fabiano Carlos [UNESP] 16 October 2009 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-10-16Bitstream added on 2014-12-02T11:21:14Z : No. of bitstreams: 1 000609546.pdf: 1464260 bytes, checksum: 34305688869576b88d9034d68dc81109 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As técnicas biomagnéticas vêm sendo empregadas com sucesso no estudo do trato gastrintestinal (TGI). Elas podem medir o campo magnético originado pela atividade elétrica dos órgãos, o campo de marcadores magnetizados ou a resposta de marcadores ou traçadores a um campo magnético de excitação. Este trabalho apresenta uma coletânea de instrumentações desenvolvidas para aplicações no trato gastrintestinal. Os equipamentos desenvolvidos utilizaram sensor anisotrópico magnetorresistivo (AMR) para medir campo magnético e conversores de tensão true rms-to-dc objetivando a redução de custo das técnicas que empregam excitação magnética alternada (AC). Foram desenvolvidos um método de localização magnética de sonda nasoenteral, uma solução para substituição dos amplificadores lock-in’s por conversores true rms, uma instrumentação com sensor AMR com um eixo de detecção para avaliar o trânsito faringiano, uma instrumentação com sensor AMR com três eixos de detecção para avaliar o trânsito esofagiano e uma instrumentação com 36 sensores que foi aplicada para obter imagens magnéticas de diferentes fantomas e para avaliar a atividade de contração gástrica em um modelo in vivo – ratos. As instrumentações foram avaliadas em testes in vitro e in vivo e apresentaram sensibilidade para o emprego no trato gastrintestinal. Os equipamentos desenvolvidos são de baixo custo, livre de radiação ionizante, portáteis e que possibilitam aplicações em gastroenterologia, farmacologia, farmacotécnica e na clínica médica. / Biomagnetic techniques have been employed successfully to study gastrointestinal (GI) tract. They are enable to measure the magnetic field of magnetized markers, the markers and tracers responses to applied magnetic field excitation, and the magnetic field occurred by GI electrical activity. This work presents some instrumentation developed to evaluate different parameters of GI tract. The equipment built uses anisotropic magnetoresistive (AMR) sensor to measure magnetic field and true rms-to-dc voltage converter in order to reduce the cost of techniques that employ alternate (AC) magnetic excitation. In this work were developed: a magnetic method for localization of enteral feeding tube, a solution to replace lock-in amplifier for true rms converter, an instrumentation using AMR sensor (one axis-sensing) to evaluate the pharyngeal transit time, another instrumentation using AMR sensor (three axis-sensing) to evaluate esophageal transit time and finally, a equipment consisted of 36 AMR sensors to evaluate the gastric motor activity from rats and in order to obtain magnetic images from different kinds of phantoms. All equipments were tested and showed sensitivity to be employed in GI studies. The equipments developed are low cost, radiation free, portable and enable to applications in gastroenterology, pharmacology, pharmaceutical and medical clinic.
9

Modelo de estudo da motilidade gastrointestinal utilizando a eletromiografia (EMG) e a biosusceptometria AC (BAC) em ratos normais, desnutridos e diabéticos induzidas pela aloxana /

Marques, Rozemeire Garcia. January 2011 (has links)
Resumo: O objetivo desse trabalho foi desenvolver um modelo experimental de análise da motilidade do Trato gastrointestinal (TGI) com potencialidades para caracterizar a atividade elétrica e mecânica do estômago e do cólon de ratos normais, diabéticos induzidos pela aloxana e desnutridos, por restrição alimentar, utilizando a eletromiografia (EMG) e a biosusceptometria AC (BAC). Ratos adultos, machos, da linhagem Wistar foram distribuídos, por sorteio, em três grupos experimentais pareados: Grupo controle - constituído de 20 animais normais, sadios, não diabéticos; Grupo diabético - constituído de 20 animais diabéticos induzidos pela aloxana, não tratados; Grupo desnutrido - constituído de 20 animais desnutridos por restrição alimentar. Cada um destes três grupos experimentais foi subdividido, por sorteio, em dois subgrupos de ratos, compostos por 10 animais cada um, para serem avaliados e sacrificados em 2 momentos distintos do experimento, 1 mês e 6 meses de seguimento. As cirurgias de implantação do conjunto eletrodo/marcador magnético na serosa gástrica e do cólon, para obtenção dos registros elétricos e mecânicos, foram realizadas respectivamente após 1 mês e 6 meses de seguimento normal, diabético e de desnutrição. Os parâmetros avaliados foram: 1) Clínicos (peso corporal, ingestão hídrica, ingestão alimentar e diurese); 2) Laboratoriais (glicemia de jejum, hemoglobina glicosilada, insulina plasmática, proteínas totais e albumina); 3) Análise da atividade elétrica e mecânica do estômago e do cólon através da EMG e da BAC. 1) a média da frequência de contração gástrica não foi alterada significantemente entre os animais normais, desnutridos e diabéticos, tanto nas avaliações feitas pela BAC, como pela EMG; 2) a regularidade no sinal da atividade de contração gástrica em ratos diabéticos, no 1º mês de seguimento, e principalmente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to develop an experimental model for analyzing the motility of the gastrointestinal tract (TGI) with potential to characterize the electrical and mechanical activity of stomach and colon of normal rats, alloxan induced diabetic and undernourished by food restriction, using electromyography (EMG) and biosusceptometry AC (BAC). Adult male rats, lineage Wistar, were divided by sorting into three groups matched: Control group - consisting of 20 normal animals were healthy, nondiabetic; diabetic group - consisting of 20 rats with alloxan induced diabetic untreated; Malnourished group - consisting of 20 malnourished rats by dietary restriction. Each of these three groups was divided by sort into two subgroups of rats, consisting of 10 animals each to be evaluated and sacrificed at two different times of the experiment, 1 month and 6 months of follow up. A surgical implantation of electrode assembly / magnetic marker in gastric serosa and colonic to obtain electric and mechanical records , were held respectively at 1 month and 6 months of normal follow-up , diabetic and malnutrition. The parameters were evaluated: 1) Clinical (body weight, water intake, food intake and urine output), 2) Laboratory (fasting glucose, glycated hemoglobin, plasma insulin, total protein and albumin), 3) Analysis of electrical and mechanical activity of stomach and colon by EMG and the BAC. 1) the average frequency of gastric contraction was not altered significantly between the normal animals, malnourished and diabetic, both the assessments made by the BAC, as the EMG, 2) the regularity of signal activity of gastric contraction in diabetic rats, at 1 month follow-up, especially at 6 months, was greatly altered compared to normal rats and malnourished, with both techniques, 3) An increased the mean frequency and amplitude of contraction in the postprandial state, compared... (Complete abstract click electronic access below) / Orientador: César Tadeu Spadella / Coorientador: José Ricardo de Arruda Miranda / Banca: Bonifácio katsunori Takegawa / Banca: Erika Veruska Paiva Ortolan / Banca: Heloisa Galvão do Amaral Campos / Banca: Ricardo Brandt de Oliveira / Doutor
10

Utilização de magnetorresistores no desenvolvimento de novas técnicas para aplicações em gastroenterologia /

Paixão, Fabiano Carlos. January 2009 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Oswaldo Baffa Filho / Banca: José Carlos Rossi / Banca: Carlos Antônio Caramori / Banca: Roberto Morato Fernandez / Resumo: Não disponível. / Abstract: Not available. / Doutor

Page generated in 0.0472 seconds