• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 9
  • 6
  • 6
  • 6
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Biorreatores com membranas : uma alternativa para o tratamento de efluentes

Silva, Maurício Kipper da January 2009 (has links)
A integração da tecnologia de separação por membrana em processos convencionais de lodos ativados representa uma inovação importante na evolução da tecnologia de tratamento biológico de efluentes. Este trabalho tem como objetivo avaliar o desempenho de um biorreator com membranas submersas, provido de um sistema de retrolavagem das membranas, utilizado para o tratamento contínuo de um efluente sintético. As membranas utilizadas foram do tipo fibras ocas e fabricadas do material poli(éter-imida). Foram testadas diferentes condições de aeração e freqüências de retrolavagens. Em todas as condições testadas foi observado o decréscimo contínuo e acentuado do fluxo permeado com o decorrer do tempo, com fluxos permeados finais aproximados de 10 L.m-2.h-1, e o sistema de biorreator com membranas aparenta não responder de forma adequada aos métodos de controle do fouling. Os experimentos mais longos, 80 horas de duração, apresentaram um decréscimo de 50% do fluxo permeado inicial nas melhores condições experimentais testadas, não sendo observado um estado estacionário para o fluxo permeado. Foi verificado que as características do efluente sintético (a base de soro de leite) têm influência na formação do fouling, já que mesmo na ausência de lodo ativado foi observada a redução do fluxo permeado de forma semelhante aos demais experimentos. Entretanto, após a substituição do efluente sintético por outro mais simples (a base de glicose e peptona) continuou sendo observado fouling intenso. Os dados experimentais foram ajustados aos modelos de Hermia e foi constatado que o mecanismo de formação de fouling segue os modelos de bloqueio completo e intermediário para a etapa inicial de permeação e o modelo de formação de camada de torta para a etapa final. Também foi realizado um estudo, em paralelo, sobre a adsorção de EPS nas membranas de poli(éter-imida). Foi verificado que a membrana de poli(éter-imida) sofre grande adsorção de EPS, mostrando elevada redução de permeabilidade. Foi proposto um modelo de redução de permeabilidade devido à adsorção de EPS que se revelou eficiente para a análise dos dados experimentais, mesmo quando utilizado na análise de dados de outros autores. / The integration of the membrane separation technology in conventional processes of activated sludge represents an important innovation in the technology evolution of biological wastewater treatment. This work evaluated the performance of a submerged membrane bioreactor, provided with a membrane backwashing system, used for the continuous treatment of a synthetic wastewater. The hollow fiber membranes were manufactured by polyetherimide material. Different aeration and backwashing cycles conditions were tested. The membrane bioreactor system seems not to answer satisfactorily to the strategies to limiting fouling. The continued and accented decrease of the permeate flux over time were observed for all the conditions tested, with final permeate fluxes approached of 10 L.m-2.h-1. The longer experiments, 80 hours of duration, presented a decrease of 50% of the initial permeate flux in the best tested experimental conditions, not being observed a steady-state permeate flux. It was verified that the synthetic effluent (whey based) has some influence in the fouling formation, since even in the absence of activated sludge it was observed a permeate flux reduction similar to that observed on the others experiments. However, intense fouling still was observed after changing the synthetic effluent for another more simple (glucose and peptone based). The experimental data were adjusted to the Hermia model. Fouling mechanism follows the complete and intermediate blocking models at the beginning of the permeation stage and the cake formation model for the later stage. A parallel study of the EPS adsorption in polyetherimide membranes was also carried out. Polyetherimide membrane presented great EPS adsorption with high permeability reduction. An EPS adsorption model was proposed and it showed efficient for experimental data analysis, even when other authors data were analyzed.
2

Biorreatores com membranas : uma alternativa para o tratamento de efluentes

Silva, Maurício Kipper da January 2009 (has links)
A integração da tecnologia de separação por membrana em processos convencionais de lodos ativados representa uma inovação importante na evolução da tecnologia de tratamento biológico de efluentes. Este trabalho tem como objetivo avaliar o desempenho de um biorreator com membranas submersas, provido de um sistema de retrolavagem das membranas, utilizado para o tratamento contínuo de um efluente sintético. As membranas utilizadas foram do tipo fibras ocas e fabricadas do material poli(éter-imida). Foram testadas diferentes condições de aeração e freqüências de retrolavagens. Em todas as condições testadas foi observado o decréscimo contínuo e acentuado do fluxo permeado com o decorrer do tempo, com fluxos permeados finais aproximados de 10 L.m-2.h-1, e o sistema de biorreator com membranas aparenta não responder de forma adequada aos métodos de controle do fouling. Os experimentos mais longos, 80 horas de duração, apresentaram um decréscimo de 50% do fluxo permeado inicial nas melhores condições experimentais testadas, não sendo observado um estado estacionário para o fluxo permeado. Foi verificado que as características do efluente sintético (a base de soro de leite) têm influência na formação do fouling, já que mesmo na ausência de lodo ativado foi observada a redução do fluxo permeado de forma semelhante aos demais experimentos. Entretanto, após a substituição do efluente sintético por outro mais simples (a base de glicose e peptona) continuou sendo observado fouling intenso. Os dados experimentais foram ajustados aos modelos de Hermia e foi constatado que o mecanismo de formação de fouling segue os modelos de bloqueio completo e intermediário para a etapa inicial de permeação e o modelo de formação de camada de torta para a etapa final. Também foi realizado um estudo, em paralelo, sobre a adsorção de EPS nas membranas de poli(éter-imida). Foi verificado que a membrana de poli(éter-imida) sofre grande adsorção de EPS, mostrando elevada redução de permeabilidade. Foi proposto um modelo de redução de permeabilidade devido à adsorção de EPS que se revelou eficiente para a análise dos dados experimentais, mesmo quando utilizado na análise de dados de outros autores. / The integration of the membrane separation technology in conventional processes of activated sludge represents an important innovation in the technology evolution of biological wastewater treatment. This work evaluated the performance of a submerged membrane bioreactor, provided with a membrane backwashing system, used for the continuous treatment of a synthetic wastewater. The hollow fiber membranes were manufactured by polyetherimide material. Different aeration and backwashing cycles conditions were tested. The membrane bioreactor system seems not to answer satisfactorily to the strategies to limiting fouling. The continued and accented decrease of the permeate flux over time were observed for all the conditions tested, with final permeate fluxes approached of 10 L.m-2.h-1. The longer experiments, 80 hours of duration, presented a decrease of 50% of the initial permeate flux in the best tested experimental conditions, not being observed a steady-state permeate flux. It was verified that the synthetic effluent (whey based) has some influence in the fouling formation, since even in the absence of activated sludge it was observed a permeate flux reduction similar to that observed on the others experiments. However, intense fouling still was observed after changing the synthetic effluent for another more simple (glucose and peptone based). The experimental data were adjusted to the Hermia model. Fouling mechanism follows the complete and intermediate blocking models at the beginning of the permeation stage and the cake formation model for the later stage. A parallel study of the EPS adsorption in polyetherimide membranes was also carried out. Polyetherimide membrane presented great EPS adsorption with high permeability reduction. An EPS adsorption model was proposed and it showed efficient for experimental data analysis, even when other authors data were analyzed.
3

Biorreatores com membranas : uma alternativa para o tratamento de efluentes

Silva, Maurício Kipper da January 2009 (has links)
A integração da tecnologia de separação por membrana em processos convencionais de lodos ativados representa uma inovação importante na evolução da tecnologia de tratamento biológico de efluentes. Este trabalho tem como objetivo avaliar o desempenho de um biorreator com membranas submersas, provido de um sistema de retrolavagem das membranas, utilizado para o tratamento contínuo de um efluente sintético. As membranas utilizadas foram do tipo fibras ocas e fabricadas do material poli(éter-imida). Foram testadas diferentes condições de aeração e freqüências de retrolavagens. Em todas as condições testadas foi observado o decréscimo contínuo e acentuado do fluxo permeado com o decorrer do tempo, com fluxos permeados finais aproximados de 10 L.m-2.h-1, e o sistema de biorreator com membranas aparenta não responder de forma adequada aos métodos de controle do fouling. Os experimentos mais longos, 80 horas de duração, apresentaram um decréscimo de 50% do fluxo permeado inicial nas melhores condições experimentais testadas, não sendo observado um estado estacionário para o fluxo permeado. Foi verificado que as características do efluente sintético (a base de soro de leite) têm influência na formação do fouling, já que mesmo na ausência de lodo ativado foi observada a redução do fluxo permeado de forma semelhante aos demais experimentos. Entretanto, após a substituição do efluente sintético por outro mais simples (a base de glicose e peptona) continuou sendo observado fouling intenso. Os dados experimentais foram ajustados aos modelos de Hermia e foi constatado que o mecanismo de formação de fouling segue os modelos de bloqueio completo e intermediário para a etapa inicial de permeação e o modelo de formação de camada de torta para a etapa final. Também foi realizado um estudo, em paralelo, sobre a adsorção de EPS nas membranas de poli(éter-imida). Foi verificado que a membrana de poli(éter-imida) sofre grande adsorção de EPS, mostrando elevada redução de permeabilidade. Foi proposto um modelo de redução de permeabilidade devido à adsorção de EPS que se revelou eficiente para a análise dos dados experimentais, mesmo quando utilizado na análise de dados de outros autores. / The integration of the membrane separation technology in conventional processes of activated sludge represents an important innovation in the technology evolution of biological wastewater treatment. This work evaluated the performance of a submerged membrane bioreactor, provided with a membrane backwashing system, used for the continuous treatment of a synthetic wastewater. The hollow fiber membranes were manufactured by polyetherimide material. Different aeration and backwashing cycles conditions were tested. The membrane bioreactor system seems not to answer satisfactorily to the strategies to limiting fouling. The continued and accented decrease of the permeate flux over time were observed for all the conditions tested, with final permeate fluxes approached of 10 L.m-2.h-1. The longer experiments, 80 hours of duration, presented a decrease of 50% of the initial permeate flux in the best tested experimental conditions, not being observed a steady-state permeate flux. It was verified that the synthetic effluent (whey based) has some influence in the fouling formation, since even in the absence of activated sludge it was observed a permeate flux reduction similar to that observed on the others experiments. However, intense fouling still was observed after changing the synthetic effluent for another more simple (glucose and peptone based). The experimental data were adjusted to the Hermia model. Fouling mechanism follows the complete and intermediate blocking models at the beginning of the permeation stage and the cake formation model for the later stage. A parallel study of the EPS adsorption in polyetherimide membranes was also carried out. Polyetherimide membrane presented great EPS adsorption with high permeability reduction. An EPS adsorption model was proposed and it showed efficient for experimental data analysis, even when other authors data were analyzed.
4

O papel de modelos de turbulência na modelagem de um biorreator com membranas

Ávila, Vinícius da Costa January 2017 (has links)
O mercado de biorreatores com membranas (BRMs) têm exibido alto crescimento. Contudo, o fouling diminui o desempenho desses sistemas drasticamente. A aeração promove a mitigação do fouling, mas possui alto custo operacional (de até 70% do total da demanda energética) e é utilizada de forma otimizada apenas 10% das vezes, gerando a necessidade de estudos sobre a hidrodinâmica em BRMs. Ferramentas de dinâmica de fluidos computacional (CFD) são úteis para esse tipo de análise. Um dos primeiros passos para encontrar uma solução apropriada em simulações numéricas é propor uma modelagem correta. Dentre os fenômenos a serem modelados, os efeitos da turbulência são provavelmente um dos mais importantes; porém, nenhum artigo que comparasse predições com base na escolha de modelo de turbulência para simulações de sistemas BRM foi encontrado. Dessa forma, o objetivo desse trabalho foi verificar a importância da escolha do modelo de turbulência para simulações de biorreatores com membranas através de CFD. Para isso, as predições obtidas de velocidade local próxima às superfícies das membranas e de tensão cisalhante nessas superfícies para duas taxas de aeração, 5 e 15 m³/h, empregando dois modelos de turbulência, k-ϵ com funções de parede para alto (aR) e para baixo número de Reynolds (bR) e k-ω SST (Shear Stress Transport) com funções de parede automáticas, na análise de um sistema BRM foram comparadas entre si e com dados experimentais e simulados disponíveis na literatura. Os perfis temporais da velocidade e da tensão cisalhante exibiram alta variabilidade no período das oscilações em certos pontos, exigindo um longo tempo de escoamento para a convergência das variáveis locais. Identificou-se a necessidade de outorgar maior importância à definição do intervalo de tempo de coleta de dados experimentais, de modo a adquirir médias representativas do perfil dinâmico das variáveis e destes perfis serem também analisados para comparações mais definitivas entre resultados de simulações e medições experimentais. As diferenças, entre as medições experimentais da literatura e predições, obtidas pelas simulações deste trabalho foram, no geral, de ordem similar ou menores que as obtidas pelas simulações na literatura. Além disso, maior atenção deve ser dada à escolha da estratégia de modelagem de turbulência, visto que houve alta sensibilidade das predições, que variaram em até 21,6% dependendo dessa escolha. / Membrane bioreactors (MBR) market has been showing high growth rates over recent years. However, membrane fouling drastically reduces MBR overall performance. Aeration promotes fouling mitigation, but at a high operational cost (up to 70% of the MBR energy demand) and it is optimally employed only in 10% of the cases. This created the need of studies focused on MBR hydrodynamic. Computational fluid dynamics (CFD) is a useful tool for hydrodynamic analysis. One of the first steps in finding a proper solution for numerical simulation is proposing a correct modelling. Among the phenomena to be modelled for MBR simulations, turbulence effects are probably one of the most important; nevertheless, no paper comparing the predictions based on the turbulence model choice for MBR simulations was found. In sight of that, this work aimed to verify the relevance of the choice of turbulence model for MBR simulations through CFD. Predictions of local velocities near membranes surfaces and of local shear stress on those surfaces, for two aeration rates (5 and 15 m³/h), employing k-ϵ with wall functions for high (aR) and low (bR) Reynolds number and k-ω SST with automatic wall functions, on the analysis of a MRB system, were compared between each other and with experimental and simulated data available in the literature. The velocity and shear stress temporal profiles showed oscillations with highly variable periods in some points, which required a long process real time to verify the local variables convergence. It was identified the need to give more importance to the definition of the time interval for experimental data collection in order to acquire reliable temporal means; also, one must properly analyze the temporal profiles for more definitive comparisons between predictions and experimental measurements. The differences, between experimental data and predictions, obtained through this work simulations were, in general, of similar order or smaller than the ones reported in the literature. Besides, more attention must be given to the turbulence modelling choices, since the predictions obtained here were highly sensitive to those choices, showing differences up to 21,6% among them.
5

O papel de modelos de turbulência na modelagem de um biorreator com membranas

Ávila, Vinícius da Costa January 2017 (has links)
O mercado de biorreatores com membranas (BRMs) têm exibido alto crescimento. Contudo, o fouling diminui o desempenho desses sistemas drasticamente. A aeração promove a mitigação do fouling, mas possui alto custo operacional (de até 70% do total da demanda energética) e é utilizada de forma otimizada apenas 10% das vezes, gerando a necessidade de estudos sobre a hidrodinâmica em BRMs. Ferramentas de dinâmica de fluidos computacional (CFD) são úteis para esse tipo de análise. Um dos primeiros passos para encontrar uma solução apropriada em simulações numéricas é propor uma modelagem correta. Dentre os fenômenos a serem modelados, os efeitos da turbulência são provavelmente um dos mais importantes; porém, nenhum artigo que comparasse predições com base na escolha de modelo de turbulência para simulações de sistemas BRM foi encontrado. Dessa forma, o objetivo desse trabalho foi verificar a importância da escolha do modelo de turbulência para simulações de biorreatores com membranas através de CFD. Para isso, as predições obtidas de velocidade local próxima às superfícies das membranas e de tensão cisalhante nessas superfícies para duas taxas de aeração, 5 e 15 m³/h, empregando dois modelos de turbulência, k-ϵ com funções de parede para alto (aR) e para baixo número de Reynolds (bR) e k-ω SST (Shear Stress Transport) com funções de parede automáticas, na análise de um sistema BRM foram comparadas entre si e com dados experimentais e simulados disponíveis na literatura. Os perfis temporais da velocidade e da tensão cisalhante exibiram alta variabilidade no período das oscilações em certos pontos, exigindo um longo tempo de escoamento para a convergência das variáveis locais. Identificou-se a necessidade de outorgar maior importância à definição do intervalo de tempo de coleta de dados experimentais, de modo a adquirir médias representativas do perfil dinâmico das variáveis e destes perfis serem também analisados para comparações mais definitivas entre resultados de simulações e medições experimentais. As diferenças, entre as medições experimentais da literatura e predições, obtidas pelas simulações deste trabalho foram, no geral, de ordem similar ou menores que as obtidas pelas simulações na literatura. Além disso, maior atenção deve ser dada à escolha da estratégia de modelagem de turbulência, visto que houve alta sensibilidade das predições, que variaram em até 21,6% dependendo dessa escolha. / Membrane bioreactors (MBR) market has been showing high growth rates over recent years. However, membrane fouling drastically reduces MBR overall performance. Aeration promotes fouling mitigation, but at a high operational cost (up to 70% of the MBR energy demand) and it is optimally employed only in 10% of the cases. This created the need of studies focused on MBR hydrodynamic. Computational fluid dynamics (CFD) is a useful tool for hydrodynamic analysis. One of the first steps in finding a proper solution for numerical simulation is proposing a correct modelling. Among the phenomena to be modelled for MBR simulations, turbulence effects are probably one of the most important; nevertheless, no paper comparing the predictions based on the turbulence model choice for MBR simulations was found. In sight of that, this work aimed to verify the relevance of the choice of turbulence model for MBR simulations through CFD. Predictions of local velocities near membranes surfaces and of local shear stress on those surfaces, for two aeration rates (5 and 15 m³/h), employing k-ϵ with wall functions for high (aR) and low (bR) Reynolds number and k-ω SST with automatic wall functions, on the analysis of a MRB system, were compared between each other and with experimental and simulated data available in the literature. The velocity and shear stress temporal profiles showed oscillations with highly variable periods in some points, which required a long process real time to verify the local variables convergence. It was identified the need to give more importance to the definition of the time interval for experimental data collection in order to acquire reliable temporal means; also, one must properly analyze the temporal profiles for more definitive comparisons between predictions and experimental measurements. The differences, between experimental data and predictions, obtained through this work simulations were, in general, of similar order or smaller than the ones reported in the literature. Besides, more attention must be given to the turbulence modelling choices, since the predictions obtained here were highly sensitive to those choices, showing differences up to 21,6% among them.
6

O papel de modelos de turbulência na modelagem de um biorreator com membranas

Ávila, Vinícius da Costa January 2017 (has links)
O mercado de biorreatores com membranas (BRMs) têm exibido alto crescimento. Contudo, o fouling diminui o desempenho desses sistemas drasticamente. A aeração promove a mitigação do fouling, mas possui alto custo operacional (de até 70% do total da demanda energética) e é utilizada de forma otimizada apenas 10% das vezes, gerando a necessidade de estudos sobre a hidrodinâmica em BRMs. Ferramentas de dinâmica de fluidos computacional (CFD) são úteis para esse tipo de análise. Um dos primeiros passos para encontrar uma solução apropriada em simulações numéricas é propor uma modelagem correta. Dentre os fenômenos a serem modelados, os efeitos da turbulência são provavelmente um dos mais importantes; porém, nenhum artigo que comparasse predições com base na escolha de modelo de turbulência para simulações de sistemas BRM foi encontrado. Dessa forma, o objetivo desse trabalho foi verificar a importância da escolha do modelo de turbulência para simulações de biorreatores com membranas através de CFD. Para isso, as predições obtidas de velocidade local próxima às superfícies das membranas e de tensão cisalhante nessas superfícies para duas taxas de aeração, 5 e 15 m³/h, empregando dois modelos de turbulência, k-ϵ com funções de parede para alto (aR) e para baixo número de Reynolds (bR) e k-ω SST (Shear Stress Transport) com funções de parede automáticas, na análise de um sistema BRM foram comparadas entre si e com dados experimentais e simulados disponíveis na literatura. Os perfis temporais da velocidade e da tensão cisalhante exibiram alta variabilidade no período das oscilações em certos pontos, exigindo um longo tempo de escoamento para a convergência das variáveis locais. Identificou-se a necessidade de outorgar maior importância à definição do intervalo de tempo de coleta de dados experimentais, de modo a adquirir médias representativas do perfil dinâmico das variáveis e destes perfis serem também analisados para comparações mais definitivas entre resultados de simulações e medições experimentais. As diferenças, entre as medições experimentais da literatura e predições, obtidas pelas simulações deste trabalho foram, no geral, de ordem similar ou menores que as obtidas pelas simulações na literatura. Além disso, maior atenção deve ser dada à escolha da estratégia de modelagem de turbulência, visto que houve alta sensibilidade das predições, que variaram em até 21,6% dependendo dessa escolha. / Membrane bioreactors (MBR) market has been showing high growth rates over recent years. However, membrane fouling drastically reduces MBR overall performance. Aeration promotes fouling mitigation, but at a high operational cost (up to 70% of the MBR energy demand) and it is optimally employed only in 10% of the cases. This created the need of studies focused on MBR hydrodynamic. Computational fluid dynamics (CFD) is a useful tool for hydrodynamic analysis. One of the first steps in finding a proper solution for numerical simulation is proposing a correct modelling. Among the phenomena to be modelled for MBR simulations, turbulence effects are probably one of the most important; nevertheless, no paper comparing the predictions based on the turbulence model choice for MBR simulations was found. In sight of that, this work aimed to verify the relevance of the choice of turbulence model for MBR simulations through CFD. Predictions of local velocities near membranes surfaces and of local shear stress on those surfaces, for two aeration rates (5 and 15 m³/h), employing k-ϵ with wall functions for high (aR) and low (bR) Reynolds number and k-ω SST with automatic wall functions, on the analysis of a MRB system, were compared between each other and with experimental and simulated data available in the literature. The velocity and shear stress temporal profiles showed oscillations with highly variable periods in some points, which required a long process real time to verify the local variables convergence. It was identified the need to give more importance to the definition of the time interval for experimental data collection in order to acquire reliable temporal means; also, one must properly analyze the temporal profiles for more definitive comparisons between predictions and experimental measurements. The differences, between experimental data and predictions, obtained through this work simulations were, in general, of similar order or smaller than the ones reported in the literature. Besides, more attention must be given to the turbulence modelling choices, since the predictions obtained here were highly sensitive to those choices, showing differences up to 21,6% among them.
7

Efeito das condições hidrodinâmicas no desempenho de um biorreator com membranas submersas em pressão constante

Cadore, Ígor Renz January 2015 (has links)
O processo de Biorreatores com Membranas (BRM) foi desenvolvido no final da década de 1960, consistindo em um sistema que associa o tratamento biológico de efluentes com o mecanismo de separação por membranas, e apresenta vantagens com relação ao tratamento convencional, tais como maior eficiência de tratamento e um menor espaço físico de instalação para a mesma capacidade de tratamento. O fenômeno de incrustação das membranas (em inglês, fouling) representa a principal limitação desse processo, de modo que uma das condições operacionais mais importantes na prevenção da incrustação em um sistema BRM Submerso (BRMS) é a vazão de aeração. Diante desta situação, o objetivo do trabalho consiste em avaliar os efeitos das condições hidrodinâmicas no desempenho do processo, tais como vazão de aeração, densidade de empacotamento do módulo de membranas e geometria dos aeradores. O sistema utilizado no trabalho consistiu em um BRMS automatizado, operando em pressão constante e de forma contínua, durante um período de 4 dias. Os módulos foram construídos com membranas poliméricas de microfiltração do tipo fibra oca, cujo material foi a poli(éter)-imida (PEI). Três diferentes vazões de aeração foram estudadas (2, 5 e 8 L.min-1), mostrando, a partir dos resultados, que existe uma vazão de aeração limite benéfica ao sistema e que, acima deste valor, um melhor desempenho não pode ser atingido, inclusive, podendo prejudicá-lo. Para o sistema de estudo, a vazão de 5 L.min-1 apresentou o melhor desempenho, seguido de 8 e 2 L.min-1. O estudo da densidade de empacotamento do módulo mostrou que esta é uma variável que também exerce influência no desempenho do processo de BRMS. Módulos com dois diferentes diâmetros foram testados (2,54 cm e 1,91 cm); o melhor resultado foi observado no módulo de maior diâmetro. A menor densidade de empacotamento resulta em um maior espaçamento entre as fibras, provocando uma aeração mais homogênea no interior do feixe de membranas. As duas geometrias de aeração testadas (Modo 1 e Modo 2) apresentaram resultados semelhantes de fluxo permeado, indicando que o Modo 2 de aeração não melhorou o desempenho do processo como se esperava. A maior homogeneidade de aeração no interior de feixe, a partir de aeradores construídos com as próprias fibras, não foi atingida, mostrando que um novo projeto de aeradores deve ser estudado. Em todas as condições hidrodinâmicas testadas, a eficiência do tratamento foi verificada, uma vez que a remoção de matéria orgânica para COT e DQO foi de 96% e 93%, respectivamente. Propriedades do permeado, como condutividade elétrica, pH e turbidez foram mensuradas, apresentando variações menores que as medidas do efluente, revelando a capacidade que o sistema apresenta em suportar as variações na corrente de alimentação. / The Membrane Bioreactor (MBR) process was developed in the late 1960. The system consists in a combination of biological process and membrane separation mechanism, and the advantages with respect of conventional treatment are the higher treatment efficiency and a smaller area of installation for the same treatment capacity. The main limitation of this process is the membrane fouling, in a way that air flow rate represents an important operating condition to prevent the fouling formation in Submerged Membrane Bioreactors (SMBR). In this sense, the aim of this work is to evaluate the effects of hydrodynamic conditions on process performance, such as air flow rate, packing density of the membrane module and aeration geometry. The system used consists in a pilot-scale SMBR, which operates at constant pressure and continuous mode during a period of 4 days. The modules were built with hollow fiber polymeric microfiltration membrane and the material is poly(ether)imide (PEI). For the three different air flow rates studied (2, 5 and 8 L.min-1), results showed there is a limit value for this parameter, in which above this value a better performance will not be obtained, even can be worse. The air flow rate of 5 L.min-1 presented the best performance, followed by 8 and 2 L.min-1. The module packing density study for two diameters (0.75 and 1 inch), the best result was observed in the larger diameter module, because lower packing density causes more space between fibres, increasing the aeration homogeneity inside de fibre bundle. Both aeration geometry tested showed similar permeate flows, indicating the different geometry used did not affect the performance process. The aerators constructed with the hollow fibers did not promote aeration homogeneity inside the bundle, and new aeration geometry must be projected. For all hydrodynamics conditions, the system treatment was efficient in removing organical matter, since the removal for TOC and COD was 96% and 93%, respectively. Permeate properties such as electrical conductivity, pH and turbidity measurements presented minor variations than effluent properties measurements, showing the system capacity to withstand with feed stream variations.
8

Efeito das condições hidrodinâmicas no desempenho de um biorreator com membranas submersas em pressão constante

Cadore, Ígor Renz January 2015 (has links)
O processo de Biorreatores com Membranas (BRM) foi desenvolvido no final da década de 1960, consistindo em um sistema que associa o tratamento biológico de efluentes com o mecanismo de separação por membranas, e apresenta vantagens com relação ao tratamento convencional, tais como maior eficiência de tratamento e um menor espaço físico de instalação para a mesma capacidade de tratamento. O fenômeno de incrustação das membranas (em inglês, fouling) representa a principal limitação desse processo, de modo que uma das condições operacionais mais importantes na prevenção da incrustação em um sistema BRM Submerso (BRMS) é a vazão de aeração. Diante desta situação, o objetivo do trabalho consiste em avaliar os efeitos das condições hidrodinâmicas no desempenho do processo, tais como vazão de aeração, densidade de empacotamento do módulo de membranas e geometria dos aeradores. O sistema utilizado no trabalho consistiu em um BRMS automatizado, operando em pressão constante e de forma contínua, durante um período de 4 dias. Os módulos foram construídos com membranas poliméricas de microfiltração do tipo fibra oca, cujo material foi a poli(éter)-imida (PEI). Três diferentes vazões de aeração foram estudadas (2, 5 e 8 L.min-1), mostrando, a partir dos resultados, que existe uma vazão de aeração limite benéfica ao sistema e que, acima deste valor, um melhor desempenho não pode ser atingido, inclusive, podendo prejudicá-lo. Para o sistema de estudo, a vazão de 5 L.min-1 apresentou o melhor desempenho, seguido de 8 e 2 L.min-1. O estudo da densidade de empacotamento do módulo mostrou que esta é uma variável que também exerce influência no desempenho do processo de BRMS. Módulos com dois diferentes diâmetros foram testados (2,54 cm e 1,91 cm); o melhor resultado foi observado no módulo de maior diâmetro. A menor densidade de empacotamento resulta em um maior espaçamento entre as fibras, provocando uma aeração mais homogênea no interior do feixe de membranas. As duas geometrias de aeração testadas (Modo 1 e Modo 2) apresentaram resultados semelhantes de fluxo permeado, indicando que o Modo 2 de aeração não melhorou o desempenho do processo como se esperava. A maior homogeneidade de aeração no interior de feixe, a partir de aeradores construídos com as próprias fibras, não foi atingida, mostrando que um novo projeto de aeradores deve ser estudado. Em todas as condições hidrodinâmicas testadas, a eficiência do tratamento foi verificada, uma vez que a remoção de matéria orgânica para COT e DQO foi de 96% e 93%, respectivamente. Propriedades do permeado, como condutividade elétrica, pH e turbidez foram mensuradas, apresentando variações menores que as medidas do efluente, revelando a capacidade que o sistema apresenta em suportar as variações na corrente de alimentação. / The Membrane Bioreactor (MBR) process was developed in the late 1960. The system consists in a combination of biological process and membrane separation mechanism, and the advantages with respect of conventional treatment are the higher treatment efficiency and a smaller area of installation for the same treatment capacity. The main limitation of this process is the membrane fouling, in a way that air flow rate represents an important operating condition to prevent the fouling formation in Submerged Membrane Bioreactors (SMBR). In this sense, the aim of this work is to evaluate the effects of hydrodynamic conditions on process performance, such as air flow rate, packing density of the membrane module and aeration geometry. The system used consists in a pilot-scale SMBR, which operates at constant pressure and continuous mode during a period of 4 days. The modules were built with hollow fiber polymeric microfiltration membrane and the material is poly(ether)imide (PEI). For the three different air flow rates studied (2, 5 and 8 L.min-1), results showed there is a limit value for this parameter, in which above this value a better performance will not be obtained, even can be worse. The air flow rate of 5 L.min-1 presented the best performance, followed by 8 and 2 L.min-1. The module packing density study for two diameters (0.75 and 1 inch), the best result was observed in the larger diameter module, because lower packing density causes more space between fibres, increasing the aeration homogeneity inside de fibre bundle. Both aeration geometry tested showed similar permeate flows, indicating the different geometry used did not affect the performance process. The aerators constructed with the hollow fibers did not promote aeration homogeneity inside the bundle, and new aeration geometry must be projected. For all hydrodynamics conditions, the system treatment was efficient in removing organical matter, since the removal for TOC and COD was 96% and 93%, respectively. Permeate properties such as electrical conductivity, pH and turbidity measurements presented minor variations than effluent properties measurements, showing the system capacity to withstand with feed stream variations.
9

Efeito das condições hidrodinâmicas no desempenho de um biorreator com membranas submersas em pressão constante

Cadore, Ígor Renz January 2015 (has links)
O processo de Biorreatores com Membranas (BRM) foi desenvolvido no final da década de 1960, consistindo em um sistema que associa o tratamento biológico de efluentes com o mecanismo de separação por membranas, e apresenta vantagens com relação ao tratamento convencional, tais como maior eficiência de tratamento e um menor espaço físico de instalação para a mesma capacidade de tratamento. O fenômeno de incrustação das membranas (em inglês, fouling) representa a principal limitação desse processo, de modo que uma das condições operacionais mais importantes na prevenção da incrustação em um sistema BRM Submerso (BRMS) é a vazão de aeração. Diante desta situação, o objetivo do trabalho consiste em avaliar os efeitos das condições hidrodinâmicas no desempenho do processo, tais como vazão de aeração, densidade de empacotamento do módulo de membranas e geometria dos aeradores. O sistema utilizado no trabalho consistiu em um BRMS automatizado, operando em pressão constante e de forma contínua, durante um período de 4 dias. Os módulos foram construídos com membranas poliméricas de microfiltração do tipo fibra oca, cujo material foi a poli(éter)-imida (PEI). Três diferentes vazões de aeração foram estudadas (2, 5 e 8 L.min-1), mostrando, a partir dos resultados, que existe uma vazão de aeração limite benéfica ao sistema e que, acima deste valor, um melhor desempenho não pode ser atingido, inclusive, podendo prejudicá-lo. Para o sistema de estudo, a vazão de 5 L.min-1 apresentou o melhor desempenho, seguido de 8 e 2 L.min-1. O estudo da densidade de empacotamento do módulo mostrou que esta é uma variável que também exerce influência no desempenho do processo de BRMS. Módulos com dois diferentes diâmetros foram testados (2,54 cm e 1,91 cm); o melhor resultado foi observado no módulo de maior diâmetro. A menor densidade de empacotamento resulta em um maior espaçamento entre as fibras, provocando uma aeração mais homogênea no interior do feixe de membranas. As duas geometrias de aeração testadas (Modo 1 e Modo 2) apresentaram resultados semelhantes de fluxo permeado, indicando que o Modo 2 de aeração não melhorou o desempenho do processo como se esperava. A maior homogeneidade de aeração no interior de feixe, a partir de aeradores construídos com as próprias fibras, não foi atingida, mostrando que um novo projeto de aeradores deve ser estudado. Em todas as condições hidrodinâmicas testadas, a eficiência do tratamento foi verificada, uma vez que a remoção de matéria orgânica para COT e DQO foi de 96% e 93%, respectivamente. Propriedades do permeado, como condutividade elétrica, pH e turbidez foram mensuradas, apresentando variações menores que as medidas do efluente, revelando a capacidade que o sistema apresenta em suportar as variações na corrente de alimentação. / The Membrane Bioreactor (MBR) process was developed in the late 1960. The system consists in a combination of biological process and membrane separation mechanism, and the advantages with respect of conventional treatment are the higher treatment efficiency and a smaller area of installation for the same treatment capacity. The main limitation of this process is the membrane fouling, in a way that air flow rate represents an important operating condition to prevent the fouling formation in Submerged Membrane Bioreactors (SMBR). In this sense, the aim of this work is to evaluate the effects of hydrodynamic conditions on process performance, such as air flow rate, packing density of the membrane module and aeration geometry. The system used consists in a pilot-scale SMBR, which operates at constant pressure and continuous mode during a period of 4 days. The modules were built with hollow fiber polymeric microfiltration membrane and the material is poly(ether)imide (PEI). For the three different air flow rates studied (2, 5 and 8 L.min-1), results showed there is a limit value for this parameter, in which above this value a better performance will not be obtained, even can be worse. The air flow rate of 5 L.min-1 presented the best performance, followed by 8 and 2 L.min-1. The module packing density study for two diameters (0.75 and 1 inch), the best result was observed in the larger diameter module, because lower packing density causes more space between fibres, increasing the aeration homogeneity inside de fibre bundle. Both aeration geometry tested showed similar permeate flows, indicating the different geometry used did not affect the performance process. The aerators constructed with the hollow fibers did not promote aeration homogeneity inside the bundle, and new aeration geometry must be projected. For all hydrodynamics conditions, the system treatment was efficient in removing organical matter, since the removal for TOC and COD was 96% and 93%, respectively. Permeate properties such as electrical conductivity, pH and turbidity measurements presented minor variations than effluent properties measurements, showing the system capacity to withstand with feed stream variations.

Page generated in 0.1294 seconds