• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 588
  • 10
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 607
  • 297
  • 202
  • 134
  • 84
  • 78
  • 74
  • 73
  • 68
  • 65
  • 63
  • 61
  • 58
  • 57
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sistemas de ventilação natural e mistos em edifícios de habitação

Amaral, Manuel António Pinto da Silva January 2008 (has links)
Tese de doutoramento. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2008
2

Nebulização a jato associada à ventilação não-invasiva : análise cintilográfica da ventilação pulmonar pela deposição do radioaerossol

Érico Tenório de França, Eduardo January 2003 (has links)
Made available in DSpace on 2014-06-12T17:36:03Z (GMT). No. of bitstreams: 2 arquivo5107_1.pdf: 1363288 bytes, checksum: e909f45720ff92e3bcaeebcfca2c1342 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / A nebulização é rotineiramente usada em situações de emergência para administração de fármacos (broncodilatadores e corticóides). A associação da nebulização com a ventilação não-invasiva (VNI) visa otimizar essa terapêutica. O objetivo deste estudo foi analisar a ventilação pulmonar regional durante a associação da nebulização com a VNI com dois níveis de pressão positiva (binível), através da cintilografia pulmonar, analisar a taxa de depuração pulmonar e ainda a correlação da deposição pulmonar com o fluxo inspiratório e o volume corrente. Foram estudados 13 voluntários, com idade de 23,30 ± 1,49 anos, sem história de doença respiratória e com valores espirométricos normais. O estudo foi realizado em duas fases: com a nebulização em respiração espontânea (RE) e outra fase associada à VNI com IPAP (12 cmH2O) e EPAP (5 cmH2O). O radioaerossol foi gerado durante 9min por um nebulizador a jato, contendo tecnécio (Tc 99m) associado ao DTPA. A cada 3min foram monitorizados: FC, FR, SO2, VC, VM e do fluxo inspiratório. Após a inalação, os voluntários permaneciam na câmara de cintilação para obtenção das imagens, nos tempos (0, 15, 30, 45 e 60) minutos. Foram delimitadas as regiões de interesse (ROIs) que foram analisadas no gradiente vertical e horizontal. Para análise estatística foram usadas Análise da Variância com medidas repetidas, comparações múltiplas de Bonferroni, teste T de Student e Análise de Regressão Simples. Observou-se que houve diminuição da deposição pulmonar do radioaerossol quando associada à VNI com a nebulização. Na análise do gradiente vertical, foi observada uma maior deposição pulmonar do radioaerossol nos terços médio e inferior em RE e associado à VNI. Já para o gradiente horizontal, a maior deposição pulmonar foi nas regiões intermediária e periférica, tanto em RE como associado à VNI. A taxa de depuração pulmonar foi de 64 min em RE e 72 min em VNI. Durante a RE houve correlação entre o aumento do volume corrente e do fluxo inspiratório com o aumento da deposição pulmonar, porém durante a associação com a VNI, essa correlação não existiu. Os achados sugerem que durante a associação da nebulização com a VNI, em voluntários normais, há um aumento do volume corrente que, associado à maior taxa de fluxo inspiratório, proporciona uma menor deposição pulmonar do radioaerossol
3

Avaliação do potencial de arrefecimento de edifícios através da ventilação natural

Verdelho, Sara Isabel Carvalho January 2008 (has links)
Tese de mestrado. Construção de Edifícios. Faculdade de Engenharia. Universidade do Porto. 2008
4

Avaliação do desempenho da ventilação natural pela ação do vento em apartamentos

Toledo, Alexandre Márcio January 2006 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil / Made available in DSpace on 2012-10-22T15:18:54Z (GMT). No. of bitstreams: 1 227983.pdf: 16253967 bytes, checksum: 90c9ca4b99b72452011a19127bd7e878 (MD5) / A ventilação natural é uma importante estratégia bioclimática no trópico quente e úmido, para reduzir o desconforto térmico e a elevada umidade do ar, substituindo a climatização artificial e contribuindo para a redução do consumo de energia elétrica pelos edifícios. Contudo, as normas e os códigos de edificações brasileiros, por se basearem na qualidade do ar, utilizam parâmetros e critérios inadequados para conforto térmico e, os métodos de estimativa apresentam limitações de aplicação aos edifícios de forma complexa. Como avaliar então o desempenho em apartamentos? O objetivo geral desta tese foi desenvolver procedimentos para avaliar o desempenho de ventilação natural pela ação do vento em apartamentos. Desenvolveu-se um Método de Análise (MASQ-VENTO), baseado no comportamento do escoamento do ar, e uma Metodologia de Avaliação (MAM-VN), baseada nas metodologias multicritérios. O objeto de aplicação foram quatro edifícios da tipologia de quatro apartamentos por andar, situados em Maceió/AL. Os desempenhos globais obtidos foram confrontados com uma avaliação realizada com arquitetos e professores locais. Verificou-se a influência tanto da geometria dos edifícios quanto da orientação dos apartamentos, bem como as correlações entre quatro indices construtivos e os desempenhos. Os resultados mostram a diferenciação dos desempenhos dos apartamentos, relativamente de acordo com as respostas dos entrevistados. Constatou-se a influência tanto da geometria dos edifícios quanto da orientação dos apartamentos nos desempenhos, apesar de as análises das variâncias não terem sido significativas. Nenhuma correlação forte foi encontrada entre os desempenhos globais obtidos e os índices construtivos; entretanto, verificou-se relação direta entre eles para a mesma orientação de apartamento. Conclui-se pela adequação do Método e da Metodologia propostos para avaliar os desempenhos e, pela inadequação dos índices construtivos para expressá-los. Sugere-se a substituição dos parâmetros e critérios utilizados pelas normas e códigos brasileiros pelos propostos, como contribuição às normas de desempenho dos edifícios, em andamento na ABNT.
5

Avaliação da eficácia e segurança da ventilação mecânica com CFR na lesão pulmonar aguda induzida pelo acido oléico

Santos, Carlos Eduardo Ventura Gaio dos January 2007 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Medicina, 2007. / Submitted by Luis Felipe Souza (luis_felas@globo.com) on 2008-11-21T19:10:23Z No. of bitstreams: 1 Tese_2007_CarlosVentura.pdf: 14546438 bytes, checksum: f9a31cd979c3c830c7e6cccbcd850a19 (MD5) / Approved for entry into archive by Georgia Fernandes(georgia@bce.unb.br) on 2009-01-15T13:02:25Z (GMT) No. of bitstreams: 1 Tese_2007_CarlosVentura.pdf: 14546438 bytes, checksum: f9a31cd979c3c830c7e6cccbcd850a19 (MD5) / Made available in DSpace on 2009-01-15T13:02:25Z (GMT). No. of bitstreams: 1 Tese_2007_CarlosVentura.pdf: 14546438 bytes, checksum: f9a31cd979c3c830c7e6cccbcd850a19 (MD5) / Introdução: O CFRR (Continuous Flow Reviver) é um dispositivo de ventilação mecânica, de disparo manual, portátil, que utiliza fluxo contínuo de gases podendo oferecer até 100% de oxigênio. Idealizado e construído em Brasília, o produto foi patenteado no Brasil e nos Estados Unidos da América. Além de oferecer pressões de admissão constantes, tem a capacidade de fornecer PEEP. Com tais predicados decidimos testar o desempenho do aparelho em ventilação de pulmões adultos lesados, cenário onde baixos volumes ventilatórios associados a pressões limitadas, sabe-se reduzirem morbidade relacionada a patologia. Para tal, estudamos a estabilidade do modelo de lesão pulmonar aguda (LPA) induzida pelo ácido oléico (AO) e utilizamos tal modelo no estudo da eficácia ventilatória e segurança hemodinâmica da ventilação com CFRR . Material e Métodos: Utilizamos 48 cães, 10 para estudar a estabilidade do modelo de LPA induzida pelo AO, 6 para controle morfológico sem LPA, 8 ventilados com o CFRR com PEEP de 5 cmH2O, 8 ventilados com o CFRR com PEEP de 10 cmH2O, 8 ventilados com ventilador microprocessado com PEEP de 5 cmH2O e 8 ventilados com ventilador microprocessado com PEEP de 10 cmH2O. Durante 120 minutos aferimos variáveis da troca gasosa, da hemodinâmica e das propriedades da mecânica pulmonar. Utilizamos metodologia de delineamento em medidas repetidas, com ajustes de modelos lineares mistos de variâncias e covariâncias diversificadas, para testar a estabilidade do modelo e comparar o desempenho da ventilação mecânica entre diversos grupos. Resultados: Observamos estabilização do modelo experimental na maioria das variáveis estudadas dentro da primeira hora do experimento. Não estabilizaram o pH, a PaCO2, o índice cardíaco e o índice de resistência vascular pulmonar. Utilizando tal modelo de LPA na ventilação com o CFRR observamos que o mesmo garante uma ventilação segura, embora tenha obtido altos fluxos inspiratórios e volume corrente. Houve troca gasosa eficaz e as alterações hemodinâmicas se encontraram dentro do esperado. Quando comparamos seu desempenho ao de ventilador microprocessado, observamos padrão de trocas gasosas, hemodinâmico e da mecânica respiratória semelhante. Conclusões: O CFRR é um ventilador eficaz e seguro na ventilação mecânica de indivíduos adultos com LPAinduzida pelo AO. __________________________________________________________________________________ ABSTRACT / Introduction: CFRR (Continuous Flow Reviver) is a manually operated, portable mechanical ventilation device that uses a continuous gas flow and o ers up to 100% of oxygen. It was idealized and built up in Brasília. The product was patented in Brazil and in the United States of America. Besides o ering constant inflow pressures, it may also provide PEEP. With such characteristics, we decided to test its performance in injured adult lung ventilation, a scenario in which low ventilation volumes associated to limited pressures is known to reduce the morbidity associated to the pathology. Therefore, we studied its stability in Oleic Acid-Induced (OAI) Acute Lung Injury (ALI) and used this experimental model to study ventilation e cacy and hemodynamics safety in CFRR ventilation. Materials and Methods: Fourty-eight dogs were used. Ten were used to study the stability of oleic acid-induced ALI experimental model, six were used for morphologic control without ALI, eight were used in CFRR ventilation with 5 cmH2O PEEP, eight with CFRR ventilation with 10 cmH2O PEEP, eight with microprocessor ventilation with 5 cmH2O PEEP and eight with microprocessor ventilator with 10 cmH2O PEEP. During 120 minutes gas exchange, hemodynamics and lung mechanical properties variables were compared. A methodology for repeated measures was used, making adjustments of the variances and covariances pattern models to test the stability of the experimental model and to compare the mechanical ventilation performance in the di erent groups. Results: Stabilization of the experimental model was observed in the majority of variables studied within the first hour of the experiment. Cardiac index, pH, PaCO2, and lung vascular resistance index were not stabilized. By using this ALI model in ventilation with CFRR we observed that it ensures safe ventilation, although it has also presented high inhalation flows and tidal volume. An e ective gas exchange was observed and hemodynamic alterations were within expectations. By comparing its performance with that of the microprocessed ventilator, similar gas exchanges, hemodynamic and ventilation patterns were observed. Conclusions: CFRR is a safe and e cient ventilator in the mechanical ventilation of adult individuals with oleic acid-induced ALI.
6

Flow 2: um modelo matematico para a analise de sistemas de ventilação natural em edificações

Caldeira Filho, Helio Callado January 1989 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro Tecnologico / Made available in DSpace on 2016-01-08T16:17:19Z (GMT). No. of bitstreams: 1 79099.pdf: 2983662 bytes, checksum: da79787572027dba21d8d75c00d8b633 (MD5) Previous issue date: 1989 / O presente trabalho tem como objetivo apresentar um modelo matemático capaz de simular processos de infiltração e/ou ventilação de ar em edificações. Para tanto o modelo leva em consideração a variação do perfil da camada limite atmosférica em função do tipo de terreno, a direção e a velocidade do vento, as dimensões da edificação, diferença de temperatura entre o ar interno e o externo, a estratificação da temperatura interna, etc. Tal modelo é capaz ainda de analisar o efeito da vazão de ar induzida sobre a umidade relativa, a temperatura e a concentração de poluentes no interior de um determinado ambiente.
7

Comparação entre ventilação mandatória intermitente e ventilação mandatória intermitente sincronizada compressão de suporte em crianças

Moraes, Marcos Aurélio de [UNESP] 13 July 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-07-13Bitstream added on 2014-06-13T19:09:57Z : No. of bitstreams: 1 moraes_ma_dr_botfm.pdf: 1377525 bytes, checksum: 4ea1013bd0b822407242800077067908 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Não há estudos que tenham comparado a ventilação mandatória intermitente (IMV) com a ventilação mandatória intermitente sincronizada associada à pressão de suporte (SIMV/PS) em crianças depois do período neonatal. Objetivos: comparar o modo IMV com o modo SIMV/PS quanto ao tempo de ventilação mecânica (TVM), tempo de desmame (TD), tempo de internação (TI) e possíveis complicações. Casuística e métodos: Ensaio clínico randomizado que incluiu crianças de 28 dias a 4 anos de idade, admitidas de 10/2002 a 06/2004 e ventiladas mecanicamente por mais de 48 horas. Os pacientes foram divididos aleatoriamente em dois grupos: grupo IMV (GIMV; n=35) e grupo SIMV/PS (GSIMV; n=35). Dados de ventilação e oxigenação foram registrados à admissão e no início do desmame. Foi, também, relatada a ocorrência de barotrauma. Pacientes com síndrome do desconforto respiratório agudo e os traqueostomizados foram excluídos. Resultados: Os grupos não diferiram quanto à idade, indicação de VM, escore PRISM, freqüência de disfunções orgânicas e evolução de parâmetros de ventilação e oxigenação. A mediana do TVM foi de 5 dias para os dois grupos (p>0,05). Da mesma forma não houve diferença estatística significante quanto ao TD [GIMV: 1 dia (1 - 6) x GSIMV: 1 dia (1 - 6); p>0,05] e quanto ao TI [GIMV: 8 dias (2 - 22) x GSIMV: 6 dias (3 - 20); p>0,05]. Houve duas falhas de extubação em cada grupo e nenhuma criança apresentou barotrauma. Conclusões: Não houve diferença estatística entre IMV e SIMV/PS neste grupo de crianças sem IRA grave, quanto aos tempos de ventilação mecânica, desmame e internação e quanto a complicações. / There are no studies comparing intermittent mandatory ventilation (IMV) and synchronous intermittent mandatory ventilation with pressure support (SIMV/PS) in post-neonatal children. Objectives: to compare IMV with SIMV/PS related to duration of mechanical ventilation/weaning and length of stay in PICU (LS). Patients and methods: Single randomized clinical trial on children between 28 days and 4 years old, admitted between 10/2002 and 06/2004, and submitted to >48h mechanical ventilation (MV). Patients were randomly assigned into two groups: IMV (IMVG; n=35) and SIMV/PS (SIMVG; n=35). Children with acute respiratory distress syndrome and tracheostomy were excluded. Ventilation and oxygenation data were recorded at admission and beginning of weaning. Results: Groups were not statistically different for age, MV indications, PRISM score, and ventilation and oxygenation parameters. Median of MV duration was 5 days for both groups (p>0.05). Also, there were no statistical differences for duration of weaning [IMVG: 1 day (1 - 6) x SIMVG: 1 day (1 - 6); p>0.05] and LS [IMVG: 8 days (2 - 22) x SIMVG: 6 days (3 - 20); p>0.05]. Conclusion: There is no statistical difference between IMV and SIMV/PS in these children related to MV and weaning duration, and PICU length of stay.
8

Comparação entre ventilação mandatória intermitente e ventilação mandatória intermitente sincronizada compressão de suporte em crianças /

Moraes, Marcos Aurélio de. January 2007 (has links)
Orientador: José Roberto Fioretto / Banca: Tatiana Rozov / Banca: Juang Horng Jyh / Banca: Martim José Faddul Alves / Banca: Mario Ferreira Carpi / Resumo: Não há estudos que tenham comparado a ventilação mandatória intermitente (IMV) com a ventilação mandatória intermitente sincronizada associada à pressão de suporte (SIMV/PS) em crianças depois do período neonatal. Objetivos: comparar o modo IMV com o modo SIMV/PS quanto ao tempo de ventilação mecânica (TVM), tempo de desmame (TD), tempo de internação (TI) e possíveis complicações. Casuística e métodos: Ensaio clínico randomizado que incluiu crianças de 28 dias a 4 anos de idade, admitidas de 10/2002 a 06/2004 e ventiladas mecanicamente por mais de 48 horas. Os pacientes foram divididos aleatoriamente em dois grupos: grupo IMV (GIMV; n=35) e grupo SIMV/PS (GSIMV; n=35). Dados de ventilação e oxigenação foram registrados à admissão e no início do desmame. Foi, também, relatada a ocorrência de barotrauma. Pacientes com síndrome do desconforto respiratório agudo e os traqueostomizados foram excluídos. Resultados: Os grupos não diferiram quanto à idade, indicação de VM, escore PRISM, freqüência de disfunções orgânicas e evolução de parâmetros de ventilação e oxigenação. A mediana do TVM foi de 5 dias para os dois grupos (p>0,05). Da mesma forma não houve diferença estatística significante quanto ao TD [GIMV: 1 dia (1 - 6) x GSIMV: 1 dia (1 - 6); p>0,05] e quanto ao TI [GIMV: 8 dias (2 - 22) x GSIMV: 6 dias (3 - 20); p>0,05]. Houve duas falhas de extubação em cada grupo e nenhuma criança apresentou barotrauma. Conclusões: Não houve diferença estatística entre IMV e SIMV/PS neste grupo de crianças sem IRA grave, quanto aos tempos de ventilação mecânica, desmame e internação e quanto a complicações. / Abstract: There are no studies comparing intermittent mandatory ventilation (IMV) and synchronous intermittent mandatory ventilation with pressure support (SIMV/PS) in post-neonatal children. Objectives: to compare IMV with SIMV/PS related to duration of mechanical ventilation/weaning and length of stay in PICU (LS). Patients and methods: Single randomized clinical trial on children between 28 days and 4 years old, admitted between 10/2002 and 06/2004, and submitted to >48h mechanical ventilation (MV). Patients were randomly assigned into two groups: IMV (IMVG; n=35) and SIMV/PS (SIMVG; n=35). Children with acute respiratory distress syndrome and tracheostomy were excluded. Ventilation and oxygenation data were recorded at admission and beginning of weaning. Results: Groups were not statistically different for age, MV indications, PRISM score, and ventilation and oxygenation parameters. Median of MV duration was 5 days for both groups (p>0.05). Also, there were no statistical differences for duration of weaning [IMVG: 1 day (1 - 6) x SIMVG: 1 day (1 - 6); p>0.05] and LS [IMVG: 8 days (2 - 22) x SIMVG: 6 days (3 - 20); p>0.05]. Conclusion: There is no statistical difference between IMV and SIMV/PS in these children related to MV and weaning duration, and PICU length of stay. / Mestre
9

Desempenho térmico de coberturas leves com ático : bancada de testes e modelo matemático

Lamberts, Roberto January 1983 (has links)
Este trabalho objetivou o desenvolvimento de uma metodologia para o estudo do desempenho térmico de coberturas leves com ático. Para tal, foi construída uma bancada de testes e elaborado um modelo matemático para simulação da transmissão de calor através destas coberturas. A bancada é constituída de dois telhados sobre uma camara com grande inércia térmica. Um telhado foi mantido como padrão, com telhas de barro vermelhas. No outro, foram tes tadas três modificações neste tipo de cobertura. Os testes fo ram real i zados em dias ensolarados de verao. Foi elaborado um í ndice que permitiu comparaçoes objetivas de desempenho térmico.O modelo matemático desenvolvido foi ajustado com base nos dados experimentais levantados. / The objective of this research was to develop a methodology to study the thermal performance of light roofs with atti . The method of approach adopted was the construction of a test bed and the development of a mathematical model . The test bed permitted the comparative analysis of two roof structures which were built alongside eachother over a chamber with great heat capacity, A traditional roof with clay tiles covered one side of the chamber; this provided a standard against which three improved types of roof, built over the other side of the chambe , were tested . A parameter was elaborated which enabledthe thermal performance of the different roofs to be compared. The mathematical model developed was calibrated using the data obtained during the course of this research work.
10

Análise estratégica de eficiência energética da ventilação em edifícios residenciais

Alves, Diogo Cortez January 2009 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2009

Page generated in 0.077 seconds