• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 17
  • 17
  • 14
  • 14
  • 11
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Graphene-modified pencil graphite bismuth-film electrodes for the determination of heavy metals in water samples using anodic stripping voltammetry

Pokpas, Keagan William January 2013 (has links)
>Magister Scientiae - MSc / Electrochemical platforms were developed based on pencil graphite electrodes (PGEs) modified with electrochemically deposited graphene (EG) sheets and Nafion-graphene (NG) nanocomposites in conjunction with an in situ plated bismuth-film (EG-PG-BiE and NG-PG-BiE). The EG- and NG-PG-BiEs were used as sensing platforms for determining Zn2+, Cd2+ and Pb2+ by square wave anodic stripping voltammetry (SWASV). EG sheets were deposited onto pencil graphite electrodes by cyclic voltammetric reduction from a graphene oxide (GO) solution, while a dip coating method was used to prepare the NG-PG-BiE. The GO and graphene, with flake thicknesses of 1.78 (2 sheets) and 2.10 nm (5 sheets) respectively, was characterized using FT-IR, HR-SEM, HR-TEM, AFM, XRD and Raman spectroscopy. Parameters influencing the electroanalytical response of the EG-PG-BiE and NG-PG-BiE such as, bismuth ion concentration, deposition potential, deposition time and rotation speed were investigated and optimized. The EG-PG-BiE gave well-defined, reproducible peaks with detection limits of 0.19 μg L-1, 0.09 μg L-1 and 0.12 μg L-1 for Zn2+, Cd2+ and Pb2+ respectively, at a deposition time of 120 seconds. The NG-PG-BiE showed similar detection limits of 0.167 μg L-1, 0.098 μg L-1 and 0.125 μg L-1 for Zn2+, Cd2+ and Pb2+ respectively. For real sample analysis, the enhanced voltammetric sensor proved to be suitable for the detection and quantitation of heavy metals below the US EPA prescribed drinking water standards of 5 mg L-1, 5 μg L-1 and 15 μg L-1 for Zn2+, Cd2+ and Pb2+ respectively.
2

Environmentally-friendly disposable Lab-on-a-chip Sensor for Point-of-Care Measurement of Heavy Metals

Jothimuthu, Preetha 20 September 2011 (has links)
No description available.
3

Investigation of heavy metal determination using electroanalytical stripping analysis / Sunkiųjų metalų inversinio elektroanalizinio nustatymo tyrimai

Verbickas, Rolandas 23 January 2014 (has links)
In this work the gallium and bismuth film plating in situ and ex situ processes were investigated. The metal film plating conditions for determination of heavy metals in water samples were optimized. When depositing Bi films on glassy carbon electrode it was found, that the addition of Br-1 changes the BiFE morphology making it more uniform and forming crystalline aggregates. The reoxidation peak of Bi was shifted to more negative potentials showing the electrocatalytic effect of bromide for the bismuth film. The addition of the other metal ions to the deposition solutions caused changes in the morphology of the Bi film It has been shown, that Cd was slowing the Bi film deposition and Pb was catalyzing this deposition. Zn(II), Cd(II), Cu(II) and Pb(II) ions were determined in the water samples using bismuth film electrode. The linear calibration curve of each metal was obtained. Good linear responses of the peak area vs. concentration were obtained for Zn(II), Cd(II), Pb(II) and Cu (II) with correlation coefficients of 0.997, 0.997, 0.999 and 0.998 respectively. The possibilities of gallium film plating were studied. The glassy carbon substrate was chosen for optimization. The optimized deposition conditions were: supporting electrolyte 0.1 M acetate buffer, deposition potential -1.7 V, deposition time 120 s, deposition temperature 40oC. The gallium influence on Pb(II) and Cd(II) deposition at the glassy carbon electrode was studied. It has been shown that Pb(II) and Cd(II)... [to full text] / Šiame darbe tiriama galio ir bismuto plėvelinių elektrodų formavimo in situ ir ex situ metodais ypatumai skirtingose sistemose. Optimizuotos bismuto ir galio plėvelinių elektrodų panaudojimo sąlygos sunkiųjų metalų koncentracijos nustatymui. Atliekant bismuto plėvelės nusodinimą ant stikliškosios anglies elektrodo nustatyta, kad papildomas Br- pridėjimas į tiriamąjį tirpalą keičia bismuto plėvelės morfologines savybes ir formuojasi tolygesnė bismuto plėvelė sudarydama kristalines struktūras. Reoksidacinė bismuto smailė pasislenka į neigiamesnių potencialo verčių pusę, kas rodo elektrokatalizinį Br- efektą bismuto plėvelės formavimuisi. Nustatyta, kad Cd(II) pridėjimas į tiriamąjį tirpalą lemia lėtesnį bismuto plėvelės nusodinimą, o Pb(II) pridėjimas katalizuoja bismuto plėvelės nusodinimą. Taip pat nustatyta, kad Pb(II) katalizuoja ir kitų metalų jonų nusodinimą. Bismuto plėvelinis elektrodas sėkmingai pritaikytas sunkiųjų metalų Cu(II), Zn(II), Pb(II), Cd(II) koncentracijos nustatymui pramoniniuose vandens mėginiuose. Gautos Zn(II), Cd(II), Cu(II) ir Pb(II) kalibravimo kreivės, kurių korealiacijos koeficientai atitinkamai yra 0,997, 0,997, 0,999 ir 0,998. Optimizuotos galio plėvelės nusodinimo sąlygos ant stikliškosios anglies elektrodo. Geriausi rezultatai gauti atliekant galio plėvelės nusodinimą 0,1 M acetatiniame buferyje (pH = 4,5) 40o C temperatūroje. Optimizuotas nusodinimo laikas ir potencialas atitinkamai yra 120 s ir -1,7 V. Tiriant galio jonų įtaką Pb(II) ir... [toliau žr. visą tekstą]
4

Sunkiųjų metalų inversinio elektroanalizinio nustatymo tyrimai / Investigation of heavy metal determination using electroanalytical stripping analysis

Verbickas, Rolandas 23 January 2014 (has links)
Šiame darbe tiriama galio ir bismuto plėvelinių elektrodų formavimo in situ ir ex situ metodais ypatumai skirtingose sistemose. Optimizuotos bismuto ir galio plėvelinių elektrodų panaudojimo sąlygos sunkiųjų metalų koncentracijos nustatymui. Atliekant bismuto plėvelės nusodinimą ant stikliškosios anglies elektrodo nustatyta, kad papildomas Br- pridėjimas į tiriamąjį tirpalą keičia bismuto plėvelės morfologines savybes ir formuojasi tolygesnė bismuto plėvelė sudarydama kristalines struktūras. Reoksidacinė bismuto smailė pasislenka į neigiamesnių potencialo verčių pusę, kas rodo elektrokatalizinį Br- efektą bismuto plėvelės formavimuisi. Nustatyta, kad Cd(II) pridėjimas į tiriamąjį tirpalą lemia lėtesnį bismuto plėvelės nusodinimą, o Pb(II) pridėjimas katalizuoja bismuto plėvelės nusodinimą. Taip pat nustatyta, kad Pb(II) katalizuoja ir kitų metalų jonų nusodinimą. Bismuto plėvelinis elektrodas sėkmingai pritaikytas sunkiųjų metalų Cu(II), Zn(II), Pb(II), Cd(II) koncentracijos nustatymui pramoniniuose vandens mėginiuose. Gautos Zn(II), Cd(II), Cu(II) ir Pb(II) kalibravimo kreivės, kurių korealiacijos koeficientai atitinkamai yra 0,997, 0,997, 0,999 ir 0,998. Optimizuotos galio plėvelės nusodinimo sąlygos ant stikliškosios anglies elektrodo. Geriausi rezultatai gauti atliekant galio plėvelės nusodinimą 0,1 M acetatiniame buferyje (pH = 4,5) 40o C temperatūroje. Optimizuotas nusodinimo laikas ir potencialas atitinkamai yra 120 s ir -1,7 V. Tiriant galio jonų įtaką Pb(II) ir... [toliau žr. visą tekstą] / In this work the gallium and bismuth film plating in situ and ex situ processes were investigated. The metal film plating conditions for determination of heavy metals in water samples were optimized. When depositing Bi films on glassy carbon electrode it was found, that the addition of Br-1 changes the BiFE morphology making it more uniform and forming crystalline aggregates. The reoxidation peak of Bi was shifted to more negative potentials showing the electrocatalytic effect of bromide for the bismuth film. The addition of the other metal ions to the deposition solutions caused changes in the morphology of the Bi film It has been shown, that Cd was slowing the Bi film deposition and Pb was catalyzing this deposition. Zn(II), Cd(II), Cu(II) and Pb(II) ions were determined in the water samples using bismuth film electrode. The linear calibration curve of each metal was obtained. Good linear responses of the peak area vs. concentration were obtained for Zn(II), Cd(II), Pb(II) and Cu (II) with correlation coefficients of 0.997, 0.997, 0.999 and 0.998 respectively. The possibilities of gallium film plating were studied. The glassy carbon substrate was chosen for optimization. The optimized deposition conditions were: supporting electrolyte 0.1 M acetate buffer, deposition potential -1.7 V, deposition time 120 s, deposition temperature 40oC. The gallium influence on Pb(II) and Cd(II) deposition at the glassy carbon electrode was studied. It has been shown that Pb(II) and Cd(II)... [to full text]
5

DETERMINAÇÃO DE Cu²⁺ EM BIOCOMBUSTÍVEIS COM USO DE ELETRODO DE FILME DE BISMUTO, APÓS ELIMINAÇÃO DA INTERFERÊNCIA DO Bi³⁺ / DETERMINATION OF Cu²⁺ IN BIOFUELS USING BISMUTH FILM ELECTRODE AFTER ELIMINATION OF INTERFERENCE OF THE Bi³⁺

Albuquerque, Daniel dos Santos 03 June 2013 (has links)
Made available in DSpace on 2016-08-19T12:56:44Z (GMT). No. of bitstreams: 1 Dissertacao Daniel.pdf: 1759359 bytes, checksum: 8e118ed0eeb57413abe7a81e44a65d3f (MD5) Previous issue date: 2013-06-03 / Despite the advantages of bismuth film electrode for the determination of trace metals and organic compounds, the Cu²⁺ is an element that has problems when measured with this electrode, since its potential is very close to the Bi³⁺, causing overlapping of peaks. This work presents an alternative to eliminate the interference of Bismuth in the determination of copper in using bismuth film electrodes (BiFE), prepared ex situ mode. The ethanol fuel samples without pre-treatment and biodiesel samples previously digested were used in order to evaluate this electroanalytical procedure. The optimization of the parameters was performed using a complete factorial design 2³ with center point. After several voltammetric experiments, optimal conditions for the determination of Cu²⁺ were the following: Edep = -1.3 V; tpre = 120s; Frequency: 60 Hertz. The voltammograms using anodic stripping voltammetry method in the square wave mode and their corresponding standard addition curves indicated that the bismuth film electrode provides a sensitive and useful procedure for the determination of Cu²⁺ in biofuels. Experiments carried out by the successive addition of aliquots of a standard solution of Cu²⁺, yielded a linear response of peak current to the concentration of metal ion. Good detection limits have been obtained for the determination of Cu²⁺ in ethanol fuel, soybean oil and tallow biodiesels respectively (4.9 x 10ˉ⁸ mol Lˉ¹; 5.60 x 10ˉ⁸ mol Lˉ¹, 1.79 x 10ˉ⁸ mol Lˉ¹). The accuracy was assessed through recovery test (recoveries of 85.6% to 97.05%) and the precision was expressed by the coefficient of variation that ranged from 10% to 18%. The method was successfully applied to two different samples of biodiesel and ethanol fuel and analyzed in triplicate. / Apesar das vantagens do Eletrodo de Filme de Bismuto (BiFE), na determinação de metais traços e compostos orgânicos, o Cu²⁺ é um elemento que apresenta problemas quando quantificado com este eletrodo, uma vez que seu potencial é muito próximo ao do Bi³⁺, causando a sobreposição de picos. Este trabalho apresenta uma alternativa para eliminação da interferência do bismuto na determinação de Cu²⁺ em biocombustíveis (etanol e biodiesel), usando um BiFE, preparado no modo ex situ. As amostras de etanol combustível foram usadas sem tratamento prévio, enquanto as amostras de biodiesel foram previamente digeridas. A otimização dos parâmetros foi realizada com o uso do planejamento fatorial completo 2³ com ponto central. Após vários experimentos voltamétricos, as condições ideais para a determinação de Cu²⁺ foram: Edep = -1,3 V; tpré = 120 s; Frequência: 60 Hertz. Os voltamogramas e suas correspondentes curvas de adição padrão indicaram que o uso do BiFE com a técnica Voltametria de Redissolução Anódica (ASV), no modo onda quadrada, indicaram que o procedimento é adequado, útil e sensível para a determinação de Cu²⁺ em biocombustíveis. Os experimentos realizados, pela adição sucessiva de alíquotas da solução padrão de Cu²⁺ proporcionaram uma resposta linear entre a corrente de pico e a concentração do íon metálico. Bons limites de detecção foram obtidos para a determinação do Cu²⁺ em Etanol combustível, biodiesel de óleo de soja e de sebo respectivamente (4,90x10ˉ⁸ mol Lˉ¹; 5,60x10ˉ⁸ mol Lˉ¹; 1,79x10ˉ⁸mol Lˉ¹). A exatidão foi avaliada através do teste de recuperação (recuperações de 85,6% a 97,05%). A precisão, expressa pelo coeficiente de variação (CV: entre 10% e 18%) foi considerada boa. O método foi aplicado com sucesso em amostras reais de biodiesel e Etanol combustível.
6

Preparação, caracterização e testes de eletrodo modificado com filme de bismuto para aplicação na análise voltamétrica de metais pesados / Preparation, characterization and test for a modified bismuth film electrode for applying in voltammetric analysis heavy metals

Fernanda Scavassa Ribeiro do Prado 21 May 2014 (has links)
Devido à alta toxicidade do mercúrio, os eletrodos contendo este metal vêm sendo substituídos por eletrodos modificados, dentre eles o filme de bismuto (f-Bi) tem demonstrado ser uma boa alternativa, pois apresentam comportamento e desempenho semelhante aos eletrodos de mercúrio, além de baixa toxicidade. A fim de se determinar os metais Cd2+ e Pb2+ em amostras de água do Rio Tietê, um eletrodo de f-Bi depositado de forma ex situ foi desenvolvido. As condições para a formação do f-Bi foram otimizadas e as melhores condições foram alcançadas utilizando uma solução de tampão acetato 0,2 mol L-1 pH 4,5 contendo 1,0x10-3 mol L-1 de Bi3+, aplicando um potencial de deposição de -0,50 V por 200 s. A determinação dos metais foi realizada através da voltametria de onda quadrada de redissolução anódica (SWASV - do inglês Square Wave Anodic Stripping Voltammetry), seus parâmetros foram otimizados e as melhores condições encontradas foram: frequência de 100 Hz; amplitude de pulso de 20 mV; step potential de 1 mV; potencial de pré-concentração de -0,925 V e tempo de pré- concentração de 450 s. Após a otimização dos parâmetros da SWASV foi construída uma curva analítica para os íons Cd2+ e Pb2+ na faixa de concentração de 5,0x10-8 a 3,0x10-6 mol L-1. As curvas analíticas apresentaram um aumento linear da corrente de pico em função da concentração dos metais com limite de detecção de 1,21 x10-7 e 1,13 x10-7 mol L-1 para o Cd e Pb, respectivamente. O método desenvolvido foi aplicado em amostras de água do rio Tietê e o f-Bi detectou Pb em concentração na ordem de 10-8 mol L-1. / Since Mercury is highly toxic, electrodes made with metal have been replaced by modified electrodes, among with bismuth film electrodes (f-Bi), and these latter ones have shown to be a good alternative, because they present both behavior and performance similar to the mercury electrodes, along with low toxicity. In order to determine Cd2+ and Pb2+ in water samples from the Tietê River, an f-Bi electrode laid up ex situ was developed. The conditions for the f-Bi formation were optimized and the best conditions were reached by using a solution of 0,2 mol L-1 acetate buffer with pH 4,5 containing 1,0 x10-3 mol L-1 of Bi3+, applying a deposition potential of -0,50 V for 200 s. Determinations of the metals was done by the square wave voltammetry anodic stripping voltammetry technique (SWASV), its parameters were optimized and the best conditions found were: 100 Hz frequency; 20 mV pulse amplitude; 1 mV step potential; -0,925 V pre-concentration potential and 450 s pre-concentration time. After the optimization of the technique an analytical curve was built with the addition of Cd2+ e Pb2+ metals in the concentration range between 5,0 x10-8 and 3,0 x10-6 mol L-1. The analytical curves showed a linear increase for the peak current in function of the concentration of the metals with detection limit of 1,21 x10-7 e 1,13 x10-7 mol L-1 for Cd and Pb, respectively. The developed method was applied in water samples from the Tietê River and the f-Bi detected Pb in a concentration of 10-8 mol L-1 order.
7

Preparação, caracterização e testes de eletrodo modificado com filme de bismuto para aplicação na análise voltamétrica de metais pesados / Preparation, characterization and test for a modified bismuth film electrode for applying in voltammetric analysis heavy metals

Prado, Fernanda Scavassa Ribeiro do 21 May 2014 (has links)
Devido à alta toxicidade do mercúrio, os eletrodos contendo este metal vêm sendo substituídos por eletrodos modificados, dentre eles o filme de bismuto (f-Bi) tem demonstrado ser uma boa alternativa, pois apresentam comportamento e desempenho semelhante aos eletrodos de mercúrio, além de baixa toxicidade. A fim de se determinar os metais Cd2+ e Pb2+ em amostras de água do Rio Tietê, um eletrodo de f-Bi depositado de forma ex situ foi desenvolvido. As condições para a formação do f-Bi foram otimizadas e as melhores condições foram alcançadas utilizando uma solução de tampão acetato 0,2 mol L-1 pH 4,5 contendo 1,0x10-3 mol L-1 de Bi3+, aplicando um potencial de deposição de -0,50 V por 200 s. A determinação dos metais foi realizada através da voltametria de onda quadrada de redissolução anódica (SWASV - do inglês Square Wave Anodic Stripping Voltammetry), seus parâmetros foram otimizados e as melhores condições encontradas foram: frequência de 100 Hz; amplitude de pulso de 20 mV; step potential de 1 mV; potencial de pré-concentração de -0,925 V e tempo de pré- concentração de 450 s. Após a otimização dos parâmetros da SWASV foi construída uma curva analítica para os íons Cd2+ e Pb2+ na faixa de concentração de 5,0x10-8 a 3,0x10-6 mol L-1. As curvas analíticas apresentaram um aumento linear da corrente de pico em função da concentração dos metais com limite de detecção de 1,21 x10-7 e 1,13 x10-7 mol L-1 para o Cd e Pb, respectivamente. O método desenvolvido foi aplicado em amostras de água do rio Tietê e o f-Bi detectou Pb em concentração na ordem de 10-8 mol L-1. / Since Mercury is highly toxic, electrodes made with metal have been replaced by modified electrodes, among with bismuth film electrodes (f-Bi), and these latter ones have shown to be a good alternative, because they present both behavior and performance similar to the mercury electrodes, along with low toxicity. In order to determine Cd2+ and Pb2+ in water samples from the Tietê River, an f-Bi electrode laid up ex situ was developed. The conditions for the f-Bi formation were optimized and the best conditions were reached by using a solution of 0,2 mol L-1 acetate buffer with pH 4,5 containing 1,0 x10-3 mol L-1 of Bi3+, applying a deposition potential of -0,50 V for 200 s. Determinations of the metals was done by the square wave voltammetry anodic stripping voltammetry technique (SWASV), its parameters were optimized and the best conditions found were: 100 Hz frequency; 20 mV pulse amplitude; 1 mV step potential; -0,925 V pre-concentration potential and 450 s pre-concentration time. After the optimization of the technique an analytical curve was built with the addition of Cd2+ e Pb2+ metals in the concentration range between 5,0 x10-8 and 3,0 x10-6 mol L-1. The analytical curves showed a linear increase for the peak current in function of the concentration of the metals with detection limit of 1,21 x10-7 e 1,13 x10-7 mol L-1 for Cd and Pb, respectively. The developed method was applied in water samples from the Tietê River and the f-Bi detected Pb in a concentration of 10-8 mol L-1 order.
8

DETERMINAÇÃO DE CÁDMIO E CHUMBO EM BIODIESEL POR VOLTAMETRIA DE PULSO DIFERENCIAL E DE REDISSOLUÇÃO ANÓDICA USANDO ELETRODO DE FILME DE BISMUTO EM MEIO ETANÓLICO / DETERMINATION OF CADMIUM AND LEAD IN BIODIESEL BY DIFFERENTIAL PULSE VOLTAMMETRY ANODIC STRIPPING USING AND FILM ELECTRODE BISMUTH IN MEDIUM ETHANOL

Guimarães, Myrna Barbosa 13 June 2011 (has links)
Made available in DSpace on 2016-08-19T12:56:37Z (GMT). No. of bitstreams: 1 Dissertacao Myrna Guimaraes.pdf: 1171373 bytes, checksum: ff939c3059a58da4ec3c89bdd21abd27 (MD5) Previous issue date: 2011-06-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work presents a simple procedure based on technique anodic stripping voltammetry (ASV) to determine Cd2+ and Pb2+ in Biodiesel (B100), without prior sample treatment, using a bismuth film electrode (BiFE), prepared as ex situ mode. Samples were simply diluted into a 0.1 mol L-1 acetate buffer ethanolic (pH 4.5), being the pH apparent (pH*) adjusted with HCl 1 mol L-1 before analysis. This intended to provide the conversion of the analytes to their inorganic forms. After optimization of the voltammetric and experimental conditions, the parameters ideal values for the determination of these metals were obtained as following: deposition potential: -1.4 V; deposition time: 180 s; scan rate: 25 mV s-1; modulation amplitude: 50 mV; pH apparent (pH*) ~ 2.0. The voltammograms and their corresponding standard analytical curves indicated that BiFE associated with ASV in the diferential pulse mode (DPASV) provide useful and sensitive procedure for determination of metal in B100 at trace level. The results showed a linear response between current and concentration of Cd2+ and Pb2+ ions. Adequates detection limits (3s, n = 5) were obtained for Cd2+ (1.71x10-8 mol L-1) and Pb2+ (1.92x10-9 mol L-1) for the analysis of B100. The accuracy was assessed by the recovery test (recoveries of 97 to 100 % for Cd2+ and 87 to 107 % for Pb2+). The precision expressed by coefficient of variation was less than 10 % for Cd2+ and less than 7 % for Pb2+. The method was applied successfully to four different biodiesel samples analyzed in triplicate. Pb2+ was quantified in three samples while Cd2+ only was found in two of the four analysed samples. The procedure showed good analytical results for a 95% of confidence level. / Este trabalho apresenta um procedimento simples baseado na técnica voltametria de redissolução anódica (ASV) para determinar Cd2+ e Pb2+ em Biodiesel (B100), sem pré tratamento da amostra, usando eletrodos de filme de bismuto (BiFE), preparado no modo ex situ. As amostras foram simplesmente diluídas em uma solução etanólica de tampão acetato, 0,1 mol L-1 (pH 4,5), sendo o pH aparente (pH*) ajustado com HCl 1 mol L-1 antes das análises. Isto foi feito com a intenção de proporcionar a conversão dos analitos para suas formas inorgânicas. Depois da otimização das condições experimentais e voltamétricas, os valores ideais dos parâmetros para a determinação dos metais foram obtidos, e são os seguintes: potencial de deposição: -1,4 V; tempo de pré-concentração: 180 s; velocidade de varredura: 25 mV s-1; amplitude de pulso: 50 mV; pH aparente (pH*) ~ 2,0. Os voltamogramas e suas curvas analíticas-padrão correspondentes indicaram que o BiFE associado com a técnica ASV no modo pulso diferencial (DPASV) proporciona um procedimento útil e sensível para a determinação de metais em B100 no nível de traços. Os resultados mostraram uma resposta linear entre a corrente de pico e a concentração dos íons Cd2+ e Pb2+. Adequados limites de detecção (3s, n = 5) foram obtidos para Cd2+ (1,7x10-8 mol L-1) e Pb2+ (1,9x10-9 mol L-1) para a análise em B100. A exatidão foi avaliada por testes de recuperação (recuperações de 97 a 100 % para Cd2+ e 87 a 107 % para Pb2+). A precisão, expressa pelo coeficiente de variação foi menor que 10 % para Cd2+ e menor que 7 % para Pb2+. O método foi aplicado com sucesso para quatro diferentes amostras de biodiesel analisadas em triplicata. Pb2+ foi quantificado em três enquanto que Cd2+ somente foi encontrado duas das quatro amostras analisadas. O procedimento apresentou-se adequado para um nível de confiança de 95%.
9

Voltametrijska karakterizacija i određivanje odabranih neonikotinoida primenom različitih elektroda na bazi ugljenika / Voltammetric characterization and determination of selected neonicotinoids using different carbon-based electrodes

Papp Zsigmond 31 January 2011 (has links)
<p><!--[if gte mso 9]><xml> <w:WordDocument> <w:View>Normal</w:View> <w:Zoom>0</w:Zoom> <w:PunctuationKerning /> <w:ValidateAgainstSchemas /> <w:SaveIfXMLInvalid>false</w:SaveIfXMLInvalid> <w:IgnoreMixedContent>false</w:IgnoreMixedContent> <w:AlwaysShowPlaceholderText>false</w:AlwaysShowPlaceholderText> <w:Compatibility> <w:BreakWrappedTables /> <w:SnapToGridInCell /> <w:WrapTextWithPunct /> <w:UseAsianBreakRules /> <w:DontGrowAutofit /> </w:Compatibility> <w:BrowserLevel>MicrosoftInternetExplorer4</w:BrowserLevel> </w:WordDocument> </xml><![endif]--><!--[if gte mso 9]><xml> <w:LatentStyles DefLockedState="false" LatentStyleCount="156"> </w:LatentStyles> </xml><![endif]--><!--[if gte mso 10]> <mce:style><! /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0pt 5.4pt 0pt 5.4pt; mso-para-margin:0pt; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} --><!--[endif] --></p><p class="MsoBodyText" style="margin-bottom: 0.0001pt;">U disertaciji je izvr&scaron;ena voltametrijska karakterizacija i određivanje pet&nbsp;neonikotinoidnih insekticida (imidakloprida, tiametoksama, klotianidina, nitenpirama i&nbsp;acetamiprida) na različitim elektrodama na bazi ugljenika, kao &scaron;to su elektroda od&nbsp;ugljenične paste, elektroda od staklastog ugljenika i bizmut-filmom modifikovani&nbsp;staklasti ugljenik. Pored ispitivanja u model-rastvorima, razvijene visokoosetljive&nbsp;diferencijalne pulsne voltametrijskemetode su primenjene za određivanje neonikotinoida&nbsp;u realnim uzorcima. Neonikotinoidi su određivani u uzorcima rečne vode i komercijalnim&nbsp;formulacijama, a praćena je i njihova fotolitička i fotokatalitička razgradnja. Radi&nbsp;potvrđivanja voltametrijskih rezultata, izvedena su komparativna merenja uz primenu&nbsp;tečne hromatografije sa detektorom od niza dioda i infracrvenespektrometrije. Detekcija&nbsp;pojedinih degradacionih proizvoda nastalih u toku ispitivanih fotodegradacionih procesa&nbsp;je praćena tečnohromatografskom metodom sa tandemskom masenospektrometrijskom&nbsp;detekcijom. Proučavana je povr&scaron;inska struktura CR 5 grafitnog praha, elektrode od&nbsp;ugljenične paste na bazi trikrezil-fosfata i elektrode od staklastog ugljenika pomoću&nbsp;skenirajuće elektronske mikroskopije.</p> / <p>This thesis is concerned with the voltammetric characterization and&nbsp;determination of five neonicotinoid insecticides (imidacloprid, thiamethoxam,&nbsp;clothianidin, nitenpyram and acetamiprid) at different carbon-based electrodes such as&nbsp;carbon paste, glassy carbon and bismuth-film modified glassycarbon. In addition to the&nbsp;investigations in model solutions, the developed highly sensitive differential pulse&nbsp;voltammetric methods were applied for the determination of neonicotinoids in real&nbsp;samples. Neonicotinoids were determined in river water samples, commercial&nbsp;formulations, and their photolytic and photocatalytic degradation was also monitored. To&nbsp;confirm the voltammetric results, comparative measurements were performed by liquid&nbsp;chromatography with diode-array detector and infrared spectrometry. Detection of some&nbsp;degradation products formed during the photodegradation processes was monitored using&nbsp;liquid chromatography with tandem mass-spectrometric detection. The surface structure&nbsp;of CR 5 graphite powder, tricresyl phosphate-based carbon paste electrode and glassy&nbsp;carbon electrode was investigated by scanning electron microscopy.</p>
10

Desenvolvimento de metodologias eletroanalíticas para determinação de pesticidas em óleo essencial de laranja / Development of electroanalytical methodologies for pesticides determination in orange essential oil

Andrade, Fernanda Ramos de 01 August 2014 (has links)
A citricultura, introduzida no Brasil na época da colonização e explorada comercialmente a partir dos anos 30 do século passado, é um setor de grande importância para o agronegócio brasileiro. Atualmente, o Brasil detém 50% da produção mundial de laranja e cerca de 85% de toda exportação mundial, representando uma captação de divisas de cerca de 2,5 bilhões de dólares por ano, devido principalmente à exportação do suco de laranja. Apesar do suco ser o principal produto de exportação da citricultura, vários subprodutos com valor comercial são obtidos durante seu processo de produção, tais como os óleos essenciais cítricos. Esses subprodutos localizam-se na casca da fruta e são obtidos durante o processo de extração do suco de laranja por prensagem a frio. Devido ao uso intensivo de pesticidas na citricultura e que muitas vezes se acumula na casca da fruta é comum à obtenção de óleos essenciais com resíduos de pesticidas, o que reduz seu preço de mercado internacional e limita sua inserção em mercados exigentes como o Europeu, Japonês e Americano, por exemplo. Este trabalho propõe o desenvolvimento de metodologias eletroanalíticas para a determinação de alguns pesticidas amplamente utilizados na citricultura brasileira e que têm sido encontrados nos óleos essenciais produzidos pelas indústrias de processamento. Inicialmente, foram realizados testes para avaliação da eletroatividade de três pesticidas (piridafention, cihexatina e bromopropilato) amplamente utilizados no Brasil, mas que são proibidos na maioria dos países importadores, sendo, portanto, de importância estratégica. Utilizando-se a técnica de voltametria cíclica verificou-se que o piridafention apresenta resposta sobre o eletrodo compósito de grafite-poliuretana (GPU), a cihexatina apresentou eletroatividade sobre o eletrodo de filme de bismuto e o bromopropilato não foi eletroativo nas superfícies eletródicas testadas. Varreduras realizadas com voltametria cíclica mostraram que o piridafention apresenta um pico de redução em -0,80 V (vs. EECS) sobre eletrodo compósito de GPU em meio ácido (tampão Britton-Robinson 0,1 mol L-1) com características de processo irreversível. Em seguida, desenvolveu-se uma metodologia eletroanalítica, utilizando a técnica de voltametria de onda quadrada (SWV), com a otimização do pH da solução (1,0) e demais parâmetros da SWV como a frequência (80 s-1), amplitude do pulso (50 mV) e incremento de varredura (&Delta;Ei = 5 mV). Curvas analíticas foram obtidas no intervalo de 1,46 a 17,1 µmol L-1, apresentando boa linearidade, com coeficiente de determinação (r2) de 0,998. Os limites de detecção (LD) e de quantificação (LQ) obtidos foram de 0,27 µmol L-1 e 0,92 µmol L-1, respectivamente. A precisão da metodologia desenvolvida foi avaliada por meio da repetibilidade e a reprodutibilidade e a exatidão determinada pelo erro relativo. Os testes de recuperação realizados pelo método de adição de padrão forneceram valores de 98%. A metodologia eletroanalítica desenvolvida para determinação do piridafention foi aplicada em amostras de óleo essencial de laranja, contaminadas com três níveis de concentração 1,5, 2,9 e 5,9 µmol L-1. Foram avaliados quatro procedimentos de extração líquido-líquido, utilizando água Milli-Q como extrator: i) agitação manual da mistura (10 mL de óleo e 10 mL de água) por 4 minutos com repetição do procedimento por 3 vezes; ii) agitação magnética da mistura (5 mL de óleo e 50 mL de água) por 20 minutos em uma única etapa, à temperatura ambiente; iii) agitação magnética da mistura (5 mL de óleo e 50 mL de água) por 20 minutos em uma única etapa, à temperatura de 45°C; iv) agitação da mistura em mesa orbital com tempo de agitação variando de 5 até 180 minutos. Os melhores resultados foram obtidos com o procedimento utilizando a agitação por mesa orbital (iv), sendo recomendado, portanto, para extração do piridafention em amostras de óleo essencial de laranja. No caso da cihexatina, os testes realizados visando à determinação de uma metodologia eletroanalítica mostraram uma baixa reprodutibilidade do eletrodo filme de bismuto inviabilizando a sua aplicação na eletroanálise da cihexatina. Entretanto, devido à importância da cihexatina e do bromopropilato recomenda-se a realização de mais estudos eletroquímicos com o objetivo de se estabelecer novos métodos de análise. / The citrus production introduced in Brazil during the colonization period and commercially exploited since 1930, is very important for the Brazilian agribusiness. Currently, Brazil is responsible for 50% of the total world citrus production and for about 85% of the citrus world exportation trade, representing an income of about 2.5 billion dollars for the country yearly. The orange juice is the major product of the citrus industry, but other commercially valuable byproducts can be obtained during the manufacturing process, such as the citrus essential oils. These byproduct, located at the orange fruit exocarp, are extracted during the juice production process by cold pressing. Due to the use of pesticides in the citrus production, these agrochemicals can be occasionally presented in extracted essential oil products as unwished residues, which significantly reduce their values in the international market and restrict their insertion in exigent markets as the European, Japanese and North American, for instance. This study aim to develop electroanalytical methodologies for the determination of some pesticides widely employed in the Brazilian citrus production and that has been found in the essential oils produced by the processing industries. Preliminar tests were conducted to evaluate the electroactivity of three pesticides (pyridaphention, cyhexatin and bromopropylate) widely applied in Brazil, but not regulated for use in most of the importing countries. Using the cyclic voltammetry technique, these experiments showed that pyridaphenthion presented a good electrochemical response on the graphite-polyurethane composite electrode (GPU), cyhexatin showed electroactivity on thin bismuth film electrode and bromopropylate was not electroactive on the tested electodes. Studies conducted using cyclic voltammetry showed that pyridaphenthion presents a reduction peak in -0.8 V (vs. ESCE) on GPU in acidic medium (Britton - Robinson buffer 0.1 mol L- 1(BR)) with features of an irreversible process. The electroanalytical methodology for pyridaphenthion analysis was developed using square wave voltammetry (SWV) with optimization of pH (1.0) and the SWV scanning parameters, as pulse frequency (80 s-1), amplitude (50 mV), and increment (&Delta;Ei = 5 mV). An analytical curve was obtained for concentrations ranging from 1.46 a 17.1 µmol L-1, showing good linearity expressed in the determination coefficient (r2) of 0.998. The detection limit (LOD) and quantification limit (LOQ) obtained were 0.27 µmol L-1 and 0.92 µmol L-1, respectively. The precision was evaluated by means its repeatability and reproductibility, while accuracy was assessed by means relative error. Recovery experiments conducted using the standard addition method provided a concentration recovering level of 98%. The electroanalytical methodology developed for pyridaphenthion was applied in citrus essential oil samples spiked with three concentration levels 1.5, 2.9 and 5.9 µmol L-1. Four liquid-liquid extraction procedures were evaluated using only Milli-Q purified water as extracting agent: i) manual stirring of the mixture (10 mL of essential oil and 10 mL of water) during 4 minutes, repeating the procedure three times; ii) magnetic stirring of the mixture (5 mL of essential oil and 50 mL of water) during 20 minutes, in a single step, at room temperature; iii) magnetic stirring of the mixture (5 mL of essential oil and 50 mL of water) during 20 minutes, in a single step, at 45o C; iv) orbital shaking of the mixture (5 mL of essential oil and 50 mL of water) for different period of times varying from 5 to 180 minutes. The best results were obtained with the procedure using the orbital shaking table (iv), which is, therefore, recommended for extraction of pyridaphention residues in citrus essential oils samples. For the cyhexatin, studies carried out aiming to determine an electroanalytical methodology, showed low reproducibility of the bismuth film, preventing its application in the electroanalysis of cyhexatin. However, due to the importance of these pesticides in citrus essential oils production it is recommended additional studies regarding the electrochemistry and electroanalysis of these chemicals.

Page generated in 0.0471 seconds