• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 25
  • 25
  • 16
  • 14
  • 11
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Monitoramento do processo de desmineralização e remineralização do esmalte dental humano durante e após o clareamento dental / Monitoring de-remineralizaton process on human enamel during and after dental bleaching

Andrade, Alessandra Pereira de 25 August 2009 (has links)
Este estudo in situ tem como proposta geral monitorar os processos de desmineralização e remineralização do esmalte dental humano durante e após o clareamento dental e como objetivos específicos: avaliar se o processo de desmineralização e remineralização do esmalte dental é influenciado pela utilização de agentes clareadores com diferentes composições e estimar o período necessário para que o esmalte dental clareado atinja os níveis de mineralização evidenciados anteriormente ao início do tratamento clareador. Dez voluntários participaram deste estudo utilizando dispositivos intra-orais contendo quatro fragmentos de esmalte dental humano cada que foram submetidos aos seguintes tratamentos: G1 - peróxido de hidrogênio 35% (Pola Office, SDI); G2 - peróxido de hidrogênio 7,5% (Pola Day, SDI); G3 - peróxido de hidrogênio 7,5% (Day White ACP, Discus Dental); G4 - ácido fosfórico 35% (Condicionador de ácido fosfórico 3M ESPE Scotchbond 3M ESPE). O período do estudo compreendeu 21 dias entre tratamento e monitoramento que foi realizado pelo método de fluorescência do tecido dental com o auxílio do equipamento QLF System. A análise estatística realizada pelo teste estatístico de ANOVA 2 fatores para mensurações repetidas e o teste de Tukey revelou haver diferenças estatísticas entre os tratamentos realizados e entre os tempos de mensuração. Após a realização do monitoramento do conteúdo mineral do esmalte dental durante e posteriormente ao término do tratamento clareador pode-se constatar que os agentes clareadores que apresentam composições químicas distintas ocasionaram diferentes níveis de desmineralização no esmalte dental humano, sendo que o composto ACP presente em um dos géis clareadores utilizados foi capaz de reduzir o processo de desmineralização durante o período de tratamento clareador. O período necessário para que o esmalte dental clareado atingisse os níveis de mineralização iniciais variaram em função do clareador utilizado, porém apenas o agente clareador que contém o composto ACP foi capaz de remineralizar completamente após 21 dias. / The overall proposal of this in situ study is to monitor the demineralization and remineralization process of human enamel during and after dental bleaching and its specific objectives are: to assess whether the process of demineralization and remineralization of enamel is influenced by the use of bleaching agents with different composition and estimate the time required to bleached enamel reaches the levels of mineralization observed prior to bleaching treatment. Ten volunteers participated of this study wearing intraoral devices containing four fragments of human enamel submitted to the following treatments: G1 - 35% hydrogen peroxide (Pola Office, SDI), G2 - 7.5% hydrogen peroxide (Pola Day, SDI); G3 - 7.5% hydrogen peroxide (Day White ACP, Discus Dental); G4 - 35% phosphoric acid (Scotchbond 3M ESPE, 3M ESPE). The study period comprised 21 days of treatment and monitoring. Monitoring was conducted by the quantitative light fluorescence method, with QLF System. Statistical analysis performed by the statistical two-way ANOVA for repeated measurements and Tukey tests demonstrated differences between treatments and between measurement times. Monitoring the enamel mineral content during and after the end of the bleaching treatment revealed that the bleaching agents with different chemical compositions resulted in different levels of human enamel demineralization and that, the ACP compound present in one of the bleaching agents used was able to reduce the demineralization process during the bleaching treatment. Time required for the bleaching human enamel reaches the initial levels of mineralization varied depending on the bleaching agent used, but only the bleaching agent containing ACP was able to completely remineralize enamel after 21 days.
2

Avaliação da citotoxicidade de agentes clareadores para uso caseiro e profissional /

Cardoso, Paula Elaine. January 2009 (has links)
Orientador: Márcia Carneiro Valera. / Banca: Samira Esteves Afonso Camargo / Banca: Brenda Paula Figueiredo de Almeida Gomes / Banca: Simone Helena Gonçalves de Oliveira / Banca: Luana Marotta Reis de Vasconcellos / Resumo: A proposta deste estudo foi avaliar a citotoxicidade dos peróxidos de hidrogênio (PH) e carbamida (PC), para uso caseiro e profissional, sobre cultura de fibroblastos de mucosa de tecido gengival humano (FMM1). As células utilizadas foram cultivadas em DMEM e após 24 horas foi colocado meio de cultivo condicionado com os agentes clareadores: G1- PC 35% sem fotoativação (SF); G2- PC 35% ativado por luz halógena; G3- PC 35% ativado por diodo emissor de luz (LED); G4- PC 37% SF; G5- PC 37% ativado por luz halógena; G6- PC 37% ativado por LED; G7- PH 3% SF; G8- PH 7,5% SF; G9- PH 9,5% SF; G10- PC 10% SF; G11- PC 15% SF e G12- PC 20% SF. Uma curva padrão de viabilidade celular foi obtida a partir de células que não receberam tratamento (controle). O ensaio com MTT foi realizado após 24 e 48 horas, para avaliar a viabilidade celular. Paralelamente, foi medido colorimetricamente a quantidade de PH liberado nas condições experimentais. Os dados da viabilidade celular obtidos foram analisados estatisticamente através dos testes ANOVA e Tukey, (p<0,05). Todos os grupos apresentaram diferença significativa em relação ao controle. Dentre os agentes clareadores para uso profissional o PC 37% apresentou maior citotoxicidade e quantidade de peróxido de hidrogênio liberada que o PC 35%. A ativação por luz halógena ocasinou maior citotoxicidade e maior quantidade de PH liberado. Dentre os agentes clareadores para uso caseiro a base de peróxido de hidrogênio houve uma maior taxa de sobrevivência celular na concentração mais baixa de peróxido de hidrogênio (PH 3%); nos clareadores a base de peróxido de carbamida houve uma maior taxa de sobrevivência celular na concentração mais baixa de peróxido de carbamida (PC 10%). A taxa de sobrevivência celular foi significantemente menor após 48 horas. Concluiu-se que a citotoxicidade foi proporcional à concentração... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the citotoxicity of hydrogen peroxide (HP) and carbamide peroxide (CP) on fibroblasts from mucosa of human gingival tissue (FMM1). The cells were cultivated in DMEM and was placed in contact with conditioned medium with bleaching agents: G1- 35% CP without curing, G2-35% CP activated by halogen light; G3- 35% CP activated by light emission diode (LED); G4- 37% CP without curing; G5- 37% CP activated by halogen lamp; G6- 37% CP activated by LED; G7- 3% HP without curing; G8- 7.5% HP without curing; G9 - 9.5% HP without curing; G10- 10% CP without curing, G11-15% CP without curing, and G12- 20% CP without curing. A standard curve of cell growth and viability was obtained from cells that received no treatment (control). The MTT test was performed after 24 and 48 hours to assess the viability and cell growth. In parallel, was measured the amount of PH released under the experimental conditions. The data of cell viability were statistically analyzed by ANOVA and Tukey's tests (p <0.05). All groups showed significant differences in relation to the control group. Among the bleaching agents for office application, the 37% CP showed higher cytotoxicity and the 35% CP released the higher quantity of hydrogen peroxide. The activation by halogen light promoted the higher cytotoxicity and higher HP released. Among the home bleaching agents based on hydrogen peroxide there was a higher rate of cell survival in low concentration of hydrogen peroxide (3% HP); the bleaching based on carbamide peroxide had a higher cell survival rate in low concentration of carbamide peroxide (CP 10%). The cell viability was significantly lower after 48 hours. It was concluded that the cytotoxicity was related to the concentration of bleaching agent and the curing with halogen light increased the hydrogen peroxide release. / Doutor
3

Monitoramento do processo de desmineralização e remineralização do esmalte dental humano durante e após o clareamento dental / Monitoring de-remineralizaton process on human enamel during and after dental bleaching

Alessandra Pereira de Andrade 25 August 2009 (has links)
Este estudo in situ tem como proposta geral monitorar os processos de desmineralização e remineralização do esmalte dental humano durante e após o clareamento dental e como objetivos específicos: avaliar se o processo de desmineralização e remineralização do esmalte dental é influenciado pela utilização de agentes clareadores com diferentes composições e estimar o período necessário para que o esmalte dental clareado atinja os níveis de mineralização evidenciados anteriormente ao início do tratamento clareador. Dez voluntários participaram deste estudo utilizando dispositivos intra-orais contendo quatro fragmentos de esmalte dental humano cada que foram submetidos aos seguintes tratamentos: G1 - peróxido de hidrogênio 35% (Pola Office, SDI); G2 - peróxido de hidrogênio 7,5% (Pola Day, SDI); G3 - peróxido de hidrogênio 7,5% (Day White ACP, Discus Dental); G4 - ácido fosfórico 35% (Condicionador de ácido fosfórico 3M ESPE Scotchbond 3M ESPE). O período do estudo compreendeu 21 dias entre tratamento e monitoramento que foi realizado pelo método de fluorescência do tecido dental com o auxílio do equipamento QLF System. A análise estatística realizada pelo teste estatístico de ANOVA 2 fatores para mensurações repetidas e o teste de Tukey revelou haver diferenças estatísticas entre os tratamentos realizados e entre os tempos de mensuração. Após a realização do monitoramento do conteúdo mineral do esmalte dental durante e posteriormente ao término do tratamento clareador pode-se constatar que os agentes clareadores que apresentam composições químicas distintas ocasionaram diferentes níveis de desmineralização no esmalte dental humano, sendo que o composto ACP presente em um dos géis clareadores utilizados foi capaz de reduzir o processo de desmineralização durante o período de tratamento clareador. O período necessário para que o esmalte dental clareado atingisse os níveis de mineralização iniciais variaram em função do clareador utilizado, porém apenas o agente clareador que contém o composto ACP foi capaz de remineralizar completamente após 21 dias. / The overall proposal of this in situ study is to monitor the demineralization and remineralization process of human enamel during and after dental bleaching and its specific objectives are: to assess whether the process of demineralization and remineralization of enamel is influenced by the use of bleaching agents with different composition and estimate the time required to bleached enamel reaches the levels of mineralization observed prior to bleaching treatment. Ten volunteers participated of this study wearing intraoral devices containing four fragments of human enamel submitted to the following treatments: G1 - 35% hydrogen peroxide (Pola Office, SDI), G2 - 7.5% hydrogen peroxide (Pola Day, SDI); G3 - 7.5% hydrogen peroxide (Day White ACP, Discus Dental); G4 - 35% phosphoric acid (Scotchbond 3M ESPE, 3M ESPE). The study period comprised 21 days of treatment and monitoring. Monitoring was conducted by the quantitative light fluorescence method, with QLF System. Statistical analysis performed by the statistical two-way ANOVA for repeated measurements and Tukey tests demonstrated differences between treatments and between measurement times. Monitoring the enamel mineral content during and after the end of the bleaching treatment revealed that the bleaching agents with different chemical compositions resulted in different levels of human enamel demineralization and that, the ACP compound present in one of the bleaching agents used was able to reduce the demineralization process during the bleaching treatment. Time required for the bleaching human enamel reaches the initial levels of mineralization varied depending on the bleaching agent used, but only the bleaching agent containing ACP was able to completely remineralize enamel after 21 days.
4

Degradation of bleaching agents under two different storage conditions

Almutiri, Basil January 2016 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / This study was conducted in order to determine if there is any change in the active ingredient of tooth-whitening agents when the products are received from the manufacturer (Baseline), two months, four months, and six months after they are received, under two different storage conditions. Thirty-six products were received from multiple manufacturers: eight with hydrogen peroxide and 28 carbamide with peroxide products. All the bleaching syringes for a specific product were from the same lot. Once the products were received, one sample of each product was stored at room temperature and the other sample was stored in a refrigerator. Assays to determine the baseline concentration were performed within the first two weeks of their arrival and again 2 months, 4 months, and 6 months after receiving the products. All samples were analyzed for peroxide content by using the United States Pharmacopeia recommended method. The results obtained from this study show the following: 1. Bleaching products have different concentrations than what are indicated on the label. 2. Storage of bleaching products for an extended time at room temperature can cause bleaching products to lose some of their potency. 3. The preferable storage condition verified in this study is under refrigeration.
5

"Efeito da técnica de clareamento no conteúdo mineral do esmalte dental humano" / The bleaching effect on human mineral dental enamel content

Andrade, Alessandra Pereira de 10 June 2005 (has links)
Este trabalho teve como objetivos: avaliar se a técnica de clareamento de auto-aplicação tem a capacidade de provocar uma perda mineral do esmalte dental humano, em função da concentração, do pH e do número de aplicações dos agentes clareadores, além de observar micromorfologicamente por meio de Microscopia Eletrônica de Varredura as superfícies de esmalte após exposição aos clareadores e ao ácido fosfórico 37%. Os produtos clareadores analisados foram o Excel 3 Day White 7.5%, Excel 3 Day White 9.5%, Pola Day 7.5%, Pola Day 9.5%, Vivastyle 10% e Vivastyle 16%. Para a análise química foram utilizados 28 incisivos centrais superiores que foram incluídos em resina acrílica de modo que uma área de 50,2 mm 2 permanecesse em contato direto com os agentes clareadores e com o ácido fosfórico. A mensuração da perda mineral foi realizada por meio de um Espectrofotômetro de Emissão Atômica por Indução de Plasma de Argônio Acoplado. As amostras foram analisadas diariamente durante uma semana e no 14° dia de clareamento. Os resultados obtidos com o auxílio do teste estatístico de Kruskal-Wallis (p=0,01) permitiram concluir que todos os agentes clareadores utilizados ocasionaram perda do conteúdo mineral do esmalte dental humano. A concentração dos agentes clareadores de mesmo pH não influenciou na quantidade dos elementos químicos perdidos. O pH dos agentes clareadores influenciou na perda mineral do esmalte humano, sendo que os clareadores com pH ácido resultaram em maiores perdas, quantidades essas semelhantes às perdidas quando o tratamento realizado foi o condicionamento ácido por 15 segundos. A perda do conteúdo mineral não foi influenciada pelas repetidas aplicações dos agentes clareadores. As fotomicrografias revelaram que todas as superfícies de esmalte submetidas aos diferentes procedimentos clareadores mostraram alterações de suas topografias originais. Irregularidades mais severas foram notadas com a utilização de produtos clareadores com pH ácido, em algumas áreas estas modificações se assemelharam às alterações causadas pelo condicionamento ácido. / The aim of this study was to evaluate the bleaching technique capacity to promote a mineral loss of the human dental enamel in function of concentration, pH and number of applications of the bleaching agent, and also SEM observing the enamel surfaces after bleaching and 37% phosphoric acid exposition. The analyzed products were the Excel 3 Day White 7,5%, Excel 3 Day White 9,5%, Pola Day 7,5%, Pola Day 9,5%, Vivastyle 10% and Vivastyle 16%. The chemical analysis had been proceeded using 28 human incisors enclosed in acrylic resin in way that an area of 50,2 mm 2 remained in direct contact with the bleaching gel and the phosphoric acid. The mineral loss was detected by ICP-AES. The samples had been analyzed daily for the period of one week and in the 14° day of bleaching. The results obtained by Kruskal-Wallis statistical test (p=0.01) had permitted to conclude that all the bleaching agents used had caused mineral content loss of the human dental enamel. The amount of lost chemical elements was not influenced when bleaching agents with the same pH where compared. The pH bleaching agent’s values had influenced in the mineral loss of the human enamel. The acidic pH had resulted in higher losses, compared to the amounts lost when the treatment was the 15 seconds acid etching. The mineral content loss was not influenced by repeated applications of the bleaching agent. The photomicrography had disclosed that all the enamel surfaces submitted to the different bleaching procedures had shown alterations of its original topography. Severe irregularities had been noticed with the use of products with acidic pH, in some areas these modifications had been similar to the alterations caused for the acid etching.
6

Avaliação de agentes remineralizadores e dessensibilizantes no tratamento de clareamento dental: estudo in vitro / Evaluating remineralizing and desensitizing agents in dental bleaching treatment: in vitro study

Pintado Palomino, Karen 15 August 2013 (has links)
O objetivo deste estudo foi avaliar comparativamente, in vitro, o efeito de agentes remineralizadores e dessensibilizantes na rugosidade superficial e microdureza do esmalte e dentina bovina exposta a peróxido de carbamida a 16% (T1) ou peróxido de hidrogênio a 35% (T2). Os agentes clareadores T1 e T2 conjuntamente com os agentes remineralizadores/ dessensibilizantes - dentifrício Sensodyne® (D1); dentifrício experimental com 7,5% de micro-partículas de Biosilicato® (D2); dentifrício Odontis RX® (D3); dentifrício Sorriso® (D4); pasta experimental com micropartículas de Biosilicato® (D5); Desensebilize Nano P® (D6); pasta experimental com micropartículas de Bioglass® tipo 45S5 (D7); água destilada (GC) - foram usados considerando os grupos experimentais: T1/D1; T1/D2; T1/D3; T1/D4; T1/D5; T1/D6; T1/D7; T1/GC e T2/D1; T2/D2; T2/D3; T2/D4; T2/D5; T2/D6; T2/D7; T2/GC. Análise de rugosidade superficial (Ra), microdureza e imagens em microscopia eletrônica de varredura (MEV) foram realizadas antes (t0) e após (t1) o tratamento com os géis clareadores (T1= 14 dias/ 4h por dia; T2= sessão única) e os produtos remineralizadores/dessensibilizantes. Os dados colhidos foram analisados intra e intergrupos, estatisticamente por meio de Análise de Variância e Teste de Tukey. Os resultados mostraram que na rugosidade superficial não houve diferença significante (p>0.05) entre a rugosidade inicial (t0) e final (t1) tanto no esmalte quanto na dentina. A microdureza diminuiu nas amostras de dentina para o grupo T1/D6 (t0=40,99/ t1=29,11) e foi aumentada nas amostras de esmalte do grupo T1/D1 (t0=255,0/ t1=318,1). Conclui-se que o tratamento com peróxido de carbamida a 16% ou peróxido de hidrogênio a 35% associado aos agentes dessensibilizante/remineralizantes avaliados neste estudo não alteraram a rugosidade superficial do esmalte e dentina bovina, no entanto a microdureza pode ser alterada quando o peróxido de carbamida a 16% é usado. / This study aimed to evaluate in vitro the effect of remineralizing and desensitizing agents on microhardness (MH) and roughness (RG) enamel and dentin bovine samples exposed to 16% carbamide peroxide (T1) or 35% hydrogen peroxide (T2). Dental bleaching agents - T1 and T2 - together with desensitizing/ remineralizing agents - Sensodyne® dentifrice (D1); experimental dentifrice containing 7,5% micron-sized particles of Biosilicate® (D2); Odontis RX® dentifrice (D3); Sorriso® dentifrice (D4); microsized particles of Biosilicate® paste (D5); Dessensebilize Nano P® (D6); Bioglass® type 45S5 paste (D7); distilled water (CG) were used according to the experimental groups: T1/D1; T1/D2; T1/D3; T1/D4; T1/D5; T1/D6; T1/D7; T1/GC and T2/D1; T2/D2; T2/D3; T2/D4; T2/D5; T2/D6; T2/D7; T2/CG. MH, RG measurements, and images using scanning electron microscopy (SEM) were made on the samples before (t0) and after (t1) the treatment with the bleaching gels (T1= 14 days/ 04 hours/day; T2=single session) and the desensitizing/remineralizing agents. Data was analyzed statistically with One way-ANOVA and posterior Tukey Test. RG evaluation revealed no significant difference (p>0.05) between baseline (t0) and final (t1) RG for all experimental groups. MH decreased in dentine samples for T1/D6 (t0=40,99/ t1=29,11) and increased in enamel samples for T1/D1 (t0=255,0/ t1=318,1). It was concluded that the treatment with carbamide peroxide at 16% or hydrogen peroxide at 35% in combination with desensitizing/ remineralizing agents didnt alter enamel and dentin surface roughness; however microhardness could be affected when peroxide carbamide at 16 % is used.
7

Efeito do protocolo clareador na degradação, alteração de pH, eficácia e segurança do gel de peróxido de hidrogênio /

Abreu, Fabrícia Stabile de Abreu. January 2019 (has links)
Orientador: Alessandra Bühler Borges / Coorientadora: Rayssa Ferreira Zanatta / Banca: Cesar Rogério Pucci / Banca: Daniele Mara da Silva Ávila Nogueira / Resumo: O objetivo deste estudo foi avaliar a degradação do peróxido de hidrogênio em altas concentrações (35-40%), durante uma simulação de sessão de clareamento de consultório, utilizando produtos comercialmente disponíveis com dois protocolos de aplicação. Foram medidas também a eficácia clareadora dos géis, a alteração de pH dos mesmos, bem como o potencial de alteração da microdureza e rugosidade superficial do esmalte. Para tal, espécimes de dentes bovinos em forma de disco com 4 mm de diâmetro e 2 mm de espessura (1 mm de esmalte e 1 mm de dentina) foram preparados para tal 105 espécimes, embutidos em resina acrílica, polidos e divididos nos seguintes grupos, de acordo com o tipo de gel clareador: Pola Office Plus (POP - SDI PH-37,5%), Opalescence Boost (OPB - Ultradent PH-40%) e Whiteness HP (WHP - FGM PH-35%). Cada grupo foi dividido em dois subgrupos conforme o protocolo de aplicação (n = 15): com e sem troca do gel clareador durante a sessão de clareamento. A alteração de cor das amostras foi medida por espectrofotometria de acordo com o sistema CIE L*a*b*, antes e após a sessão de clareamento. A superfície do esmalte foi analisada com microdurômetro e perfilômetro, para mensuração da microdureza Knoop (KHN) e rugosidade superficial (Ra). Outros 30 espécimes adicionais em dentes bovinos foram confeccionados para mensuração da concentração do peróxido de hidrogênio e pH. A concentração e pH dos géis foram medidos por meio da titulação com permanganato de potássio (KMnO4) e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the degradation of hydrogen peroxide at high concentrations (35-40%) during a clinic whitening session simulation using commercially available products with two application protocols. The bleaching efficiency of the gels, pH change, as well as the alteration potential of the enamel microhardness and surface roughness (Ra) were measured. For this, disc-shaped bovine tooth specimens of 4 mm diameter and 2 mm thickness (1 mm enamel and 1 mm dentin) were prepared 105 specimens, embedded in acrylic resin, polished, and divided into the following groups according to the type of bleaching gel: Pola Office Plus (POP - SDI PH-37,5%), Opalescence Boost (OPB - Ultradent PH-40%), and Whiteness HP (WHP - FGM PH-35%). Each group was divided into two subgroups, according to the application protocol (n = 15): with and without exchange of the gel during the whitening session. The specimens' color change was measured by spectrophotometry according to the CIE system L*a*b*, before and after the bleaching session. The enamel surface was analyzed with a microhardner and profilometer, to measure the Knoop microhardness and surface roughness (Ra). Another 30 specimens in bovine teeth were made to measure the hydrogen peroxide concentration and pH. The concentration and pH of the gels were measured by titration with potassium permanganate (KMnO4) and by a pH meter and specific electrode, respectively, before and after said application times thereof. The degradation of the gels was calculated as a function of the initial concentration. The results were submitted to the ANOVA test and Tukey's multiple comparison test (5%). All gels presented similar bleaching efficacy (ΔE and ΔE00) comparing SA and MA. There were no significant differences between KHN and Ra means comparing SA and MA for the same gel. Although peroxide degradation significantly increased with time, the final gels concen.. / Mestre
8

The degradation of ethyl 3,4,6-tri-O-methyl-beta-D-arabino-hexopyranosidulose in aqueous alkaline hydrogen peroxide solution

Niebauer, Robert J. (Robert Joseph) 01 January 1979 (has links)
No description available.
9

Avaliação do efeito de diferentes agentes clareadores na rugosidade superficial e estabilidade de cor de dois compósitos / In vitro evaluation of different bleaching agents on the roughness and color stability of two dental composites

Anna Paula Kalix França Mendes 13 February 2009 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar, in vitro, o efeito de dois clareadores a base de peróxido de hidrogênio a 10% e a 35%, Rembrandt Whitening Pen/Oral B e Whiteness HP Maxx/FGM na estabilidade de cor e rugosidade superficial de dois compósitos, sendo um nanohíbrido TPH3/ Dentsply e outro nanoparticulado Filtek Z350/3M ESPE. Foram confeccionados 40 corpos de prova a partir de uma matriz de aço inox com dimensões de 21,0 mm de diâmetro e 2,00 mm de profundidade e divididos em dois grupos conforme o compósito a ser avaliado e submetidos aos seguintes experimentos: Exp. I Ação dos agentes clareadores na estabilidade de cor dos compósitos; Exp. II - Ação dos agentes clareadores na rugosidade superficial dos compósitos; Exp. III - Ação do polimento de superfície na rugosidade superficial e retomada de cor dos compósitos. Tanto a rugosidade como a estabilidade de cor foi avaliada em rugosímetro Mitutoyo SJ 201P e Espectofotômetro de Reflectância Perkin Elmer Lambda 35 UV/VIS respectivamente durante as seguintes etapas do experimento: T0 - após a confecção dos corpos de prova, T1 - após envelhecimento acelerado das amostras por 24 horas por luz ultravioleta, T2 - após submetidas a dois corantes: café e açaí por 7 dias, T3 - após submetidas aos agentes clareadores e T4- após polimento das mesmas. Durante todo o experimento os corpos de prova foram mantidos em saliva artificial e estufa calibrada a 37oC. Os resultados foram tratados estatisticamente por ANOVA e testes de Tukey, comparações múltiplas de Bonferroni e SNK com 5% de significância. Não foram observadas diferenças estatisticamente significantes entre os corantes, o mesmo acontecendo quando os clareadores foram comparados por Teste-t de Student com 5% de significância. Baseado nos resultados obtidos pôde-se concluir que o compósito TPH3 foi mais afetado pelos corantes que o compósito Z350. Os agentes clareadores não foram capazes de promover clareamento dos compósitos nos tempos testados, porém o polimento possibilitou retorno à condição de cor inicial (envelhecida) para o compósito TPH3 o mesmo não acontecendo para o Z350. O polimento não determinou retorno à condição original de rugosidade para qualquer dos compósitos. / The objective of this study was to evaluate, in vitro, the effects of two commercially available bleaching agents containing hydrogen peroxide, Rembrandt Whitening Pen/Oral B and Whiteness HP Maxx/FGM, on the surface roughness and on color change of two composites (TPH3/Dentsply and Filtek Z350/3M ESPE). Twenty specimens of each material were constructed by using a stainless matrix, measuring 21.0 mm diameter and 2.00 mm depth and divided in three groups according the experiments. Group I- effect of the bleaching agents on the composites color change; Group II- effect of the bleaching agents on surface roughness; Group III- effect of polishing procedures on the surface roughness and on color change of the composites. The color measurements were done using a reflectance spectrophotometer Perkin Elmer Lambda 35 UV/VIS according to the CIE L*a*b* color scale and the roughness measurements were obtained using a digital Mitutoyo rugosimeter SJ 201P. The measurements were made in five times: T0: after the specimen preparation; T1: after accelerated aging for 24 hours UV light; T2: after immersed for 07 days at 37o C in either coffee or açaí (a typical fruit of North of Brazil); T3: after bleaching procedures and T4: after finishing and polishing. The results were statistical treated by ANOVA and the differences treated by Tukey, Bonferroni`s test and SNK with 5% of significance. According t-Test with 5% of significance, there were no differences between the staining (coffee and açaí) and neither between the bleaching agents tested. The composite TPH3 showed higher values of discoloration when compared with Filtek Z350, The bleaching agents were not able to improve any kind of whitening on the composites surface. The polishing procedures after bleaching were effective on return the TPH3 to its original color, but they were not capable to return the original roughness of both of the composites.
10

Ação de enxaguatórios clareadores e sua associação ao clareamento caseiro com peróxido de carbamida / Efficacy of whitening mouthrinses and association to home bleaching with carbamide peroxide

Oliveira, Juliana Boa Sorte de [UNESP] 13 January 2016 (has links)
Submitted by JULIANA BOA SORTE DE OLIVEIRA null (grc@unesp.br) on 2016-03-16T06:46:22Z No. of bitstreams: 1 Dissertação - Juliana Boa Sorte.pdf: 1304673 bytes, checksum: dde4b206040aaf2ec3e5e04e1bf030eb (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-03-18T12:55:01Z (GMT) No. of bitstreams: 1 oliveira_jbs_me_sjc.pdf: 1304673 bytes, checksum: dde4b206040aaf2ec3e5e04e1bf030eb (MD5) / Made available in DSpace on 2016-03-18T12:55:01Z (GMT). No. of bitstreams: 1 oliveira_jbs_me_sjc.pdf: 1304673 bytes, checksum: dde4b206040aaf2ec3e5e04e1bf030eb (MD5) Previous issue date: 2016-01-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivos: o objetivo deste estudo foi comparar a efetividade de enxaguatórios clareadores sobre dentes, clareados previamente ou não, expostos a corantes alimentícios. Material e Método: Cento e vinte espécimes de esmalte e dentina de 3 mm de diâmetro foram obtidos a partir de incisivos bovinos. Os espécimes foram manchados por 14 dias em caldo de manchamento. Após o manchamento, a leitura inicial da cor foi realizada, por meio do espectrofotômetro CM-2600d (Konica Minolta, Osaka, Japão). Sessenta espécimes (Subgrupos PC) foram submetidos ao clareamento com Peróxido de Carbamida a 10% por 14 dias. Após, foram subdividos em 4 subgrupos, com ciclos de manchamento (5 min) e enxaguatório (2 min) por 12 semanas, sendo PC-LI: Listerine Whitening Pré-escovação; PC-PL: Plax Whitening; PC-BP: Bromelina + Papaína; PC-AG: água deionizada. Os subgrupos LI, PL, BP e AG foram submetidos aos mesmos ciclos citados, porém não foram submetidos ao clareamento prévio. A leitura de cor dos espécimes foi feita após 4, 8 e 12 semanas de tratamento com os enxaguatórios. Os dados foram coletados e submetidos à Análise de variância (ANOVA) de medidas repetidas. A comparação entre os subgrupos para a avaliação das diferenças estatísticas foi realizada pelo Teste de Tukey. Todos os testes empregados admitiram 5% como nível de significância estatística. Os resultados mostraram que os valores de ΔL*, Δa*, Δb* e ΔE* confirmaram o clareamento para os subgrupos PC-LI, PC-PL, PC-BP e PC-AG, após o tratamento com peróxido de carbamida, e para os subgrupos PC-LI, PC-PL, LI e PL, após os ciclos manchamento-enxaguatório. Os subgrupos PC-BP e BP assemelharam-se aos subgrupos controle PC-AG e AG. Conclui-se, desse modo, que o enxaguatório bucal Listerine Whitening apresentou maior efeito clareador, seguido do enxaguatório Plax Whitening. Porém, nenhum desses enxaguatórios foi capaz de produzir clareamento semelhante ao evidenciado pelo Peróxido de Carbamida. O enxaguatório contendo Bromelina e Papaína em sua composição não evidenciou efeito clareador, assemelhando-se aos subgrupos controle. / Objectives: The aim of this study was to compare the effectiveness of whitening mouthrinses on teeth previously whitened or not, exposed to food dyes. Material and Methods: One hundred and twenty specimens of enamel and dentin of 3 mm in diameter were obtained from bovine incisors. The specimens were stained for 14 days in broth staining. After staining, the initial color reading was performed by a spectrophotometer CM-2600d (Konica Minolta, Osaka, Japan). Sixty specimens (Subgroups CP) were submitted to whitening (Carbamide Peroxide 10%) for 14 days. Then they were subdivided into 3 subgroups, and were submitted to cycles of staining (5 min) and mouthrinse (2 min) for 12 weeks, with CP-LI: Listerine Whitening Pré-Escovação; CP-PL: Plax Whitening; CP-BP: Bromelain + Papain; CP-DW: deionized water. LI, LP, BP and DW subgroups were submitted to the same cited cycles, but without bleaching before. The color measurements were performed after 4, 8 and 12 weeks of treatment with mouthrinses. Data were collected and subjected to analysis of variance (ANOVA) for repeated measures. The comparison between the subgroups for the evaluation of statistical differences was performed by Tukey test. All tests admitted statistical significance level of 5%. The results showed that the values ΔL*, Δa*, Δb* and ΔE* confirmed bleaching to PC-LI, PC-PL, PC-BP and PC-DW subgroups, after treatment with carbamide peroxide and to CP-LI, CP-PL, LI and PL subgroups, after the staining-mouthrinse cycles. CP-BP and BP subgroups were similar to CP-DW and DW. We conclude, therefore, that the mouthrinse Listerine Whitening presented the highest bleaching effect, followed by mouthrinse Plax Whitening. Both of them were able to maintain the bleaching effect of CP after 12 weeks of dye-rinse cycles. However, none of these rinses was able to produce whitening similar to that evidenced by the Carbamide Peroxide. The mouthrinse containing Bromelain and Papain in its composition did not show bleaching effect, resembling the control subgroups.

Page generated in 0.0962 seconds