Spelling suggestions: "subject:"bonding agents"" "subject:"conding agents""
31 |
Evaluation of bonding agent application on concrete patch performanceDonjuan, Jose January 1900 (has links)
Master of Science / Department of Civil Engineering / Kyle Riding / The durability of partial depth concrete repair is directly related to the bond strength between the repair material and existing concrete. The wait time effects of cementitous grouts, epoxy, acrylic latex, and polyvinyl acetate bonding agents were observed on bond strength. Three rapid repair materials were as a comparison to bond strength, as well as concrete samples with no bonding agents having dry conditions and saturated surface dry moisture condition.
The bonding agents and rapid repair materials were tested in a controlled laboratory environment. Bond strength loss with wait times of 0, 2, 5, 10, and 30 minutes were observed when bonding agents were applied. The laboratory samples were loaded using a direct shear test. Field tests were performed using the same repair materials and bonding agents. When the agents were applied in the field the wait times used were 0, 15, 30, and 45 minutes. 7 day and 5 month pull off tensile tests were performed during the field experiment.
The data from both experiments show that when using cement grout bonding agents the high bond strength can be obtained when the repair material is applied within 15 minutes of application of the cement grout, and after 15 minutes bond loss can be expected. Wait time didn't have a significant effect on epoxy and acrylic latex bonding agents as long as they were placed before setting. The polyvinyl acetate agent and repair materials can develop high bond strength in laboratory settings, but when used in the field the bond strengths experience loss. When not using bonding agents in a repair, adequate bond strength can be obtained when using saturated surface dry condition.
|
32 |
Análise da qualidade da interface adesiva dentinária produzida por diferentes sistemas adesivos, aplicados \'in vivo\' e \'in vitro\'Sene, Fabio 17 November 2004 (has links)
O objetivo deste trabalho foi analisar em Microscopia Ótica (MO), Espectroscopia micro-Raman (µR) e Microscopia Eletrônica de Varredura (MEV), a interface adesiva em dentina proporcionada por três sistemas adesivos aplicados in vivo e in vitro. Na condição in vivo, pacientes com primeiros prémolares superiores hígidos indicados para extração, por razões ortodônticas, foram utilizados. Cavidades classe I com 0,5mm além da junção esmalte-dentina foram realizadas, nos dentes, com broca carbide 245 em alta rotação. Foram, então aplicados três sistemas adesivos diferentes foram aplicados, de acordo com as instruções dos respectivos fabricantes: Single Bond (SB-3M), Clearfil SE Bond (CSEB-Kuraray) e One Up Bond-F (OUB-Tokuyama). Aplicados esses, as cavidades foram restauradas incrementalmente com resina composta TPH Spectrum (Dentsply). Em seguida os dentes foram extraídos e armazenados em solução de timol a 0,1%. In Vitro, os mesmos procedimentos foram realizados em pré-molares extraídos. Após os dentes foram levados à uma máquina de cortes e seccionados, com auxílio de um disco de corte em espécimes contendo a interface, com dimensões 2mmx2mmx6mm de comprimento, sendo 2 espécimes para cada dente. Um dos espécimes foi levado a um micrótomo de tecido duro onde fatias com espessura de 5µm foram obtidas e coradas com Tricromo de Goldner. As fatias foram, então, analisadas em um microscópio óptico com aumento de 100 vezes. Nesta técnica a dentina mineralizada se cora de verde, o colágeno não infiltrado de vermelho e o sistema adesivo de beje translúcido. Após o mesmo espécime foi utilizado para análise em espectroscopia micro-Raman. O espécime adjacente foi desidratado em seqüência ascendente de etanol e analisado em microscopia eletrônica de varredura. Os resultados da MO para o sistema SB mostraram a presença de uma grande área corada de vermelho, indicando colágeno exposto ou não devidamente infiltrado pelo sistema adesivo para ambas as situações porém, in vivo, esta camada se mostrou maior. Para o sistema CSEB esta camada se corou de roxa, consistente ao longo de toda interface, indicando também a presença de colágeno disponível para reação com o corante, para ambas as situações. Para o sistema OUB esta camada também se corou de roxa, porém in vivo esta se mostrou mais fina e irregular que in vitro. Em MEV o sistema SB apresentou uma camada híbrida granular e porosa para ambas as situações. In vitro esta se mostrou mais espessa e regular ao longo da interface ao contrário da condição in vivo. Grandes diferenças foram observadas em relação aos tags de resina, onde in vivo, se apresentaram mais finos e curtos. Para o sistema CSEB a camada híbrida se mostrou mais fina quando comparada ao sistema SB porém, mais homogênea e compacta ao longo da interface para ambas as situações. Grandes diferenças foram observadas em relação aos tags de resina onde in vivo foram significativamente em menor número, curtos e finos. Para o sistema OUB in vitro a camada híbrida se apresentou fina porém, homogênea em sua extensão com a presença de longos tags. In vivo a camada híbrida se apresentou bastante fina e até difícil de se detectar. O tags se apresentaram quase inexistes ou muito dobrados devido à pobre polimerização desse sistema. As análises em µR para o sistema SB mostraram uma maior contribuição do sistema adesivo nos dois primeiros micrometros da interface, ao passo que, no restante da mesma, houve pouca contribuição dos monômeros adesivos na proteção do colágeno. Para o sistema CSEB a interface se mostrou bastante fina (1µm), para ambas as condições, porém com contribuição, no complexo hibridizado, dos componentes adesivos, colágeno e mineral. Para o sistema OUB in vitro, os espectros também indicaram a presença de uma interface fina, em torno de 1µm, mas também com contribuição dos componentes adesivos, colágeno e mineral. In vivo, esta não pôde ser detectada pelo Raman por ser inexistente ou ser mais fina que a resolução do Raman (1 µm). Realizada as análises da interface em ambas condições experimentais, com os diferentes sistemas adesivos utilizados, conclui-se que: a condição in vivo proporcionou uma interface de menor qualidade para todos os sistemas. O sistema CSEB aparentemente proporcionou uma melhor qualidade de interface e o sistema OUB a pior. O uso dessas três técnicas integradas permitiu uma análise completa, qualitativa e quantitativa da interface adesiva produzida por esses três sistemas, em ambas as condições testadas. / The aim of this research was to analyze in Light Microscopy (LM), micro-Raman Spectroscopy (µR) and Scanning Electron Microscopy (SEM), the dentin-adhesive interface produced by three different bonding systems applied in vivo and in vitro. In in vivo condition patients with the first upper premolars, to be extract for orthodontic reasons, were used. Class I cavities with 0.5mm below the dentin-enamel junction were performed, with carbide bur in high speed. Following, three different bonding systems were applied in accordance with their manufacturer instruction: Single Bond (SB-3M), Clearfil SE Bond (CSEB-KURARAY) and One Up Bond-F (OUBTokuyama), and the cavities restored, incrementally, with composite resin TPH Spectrum (Dentsply). After restoration the teeth were extracted and stored in 0,1% tymol solution. In vitro, the same procedures were performed in extracted upper premolars. Following, the teeth were taken to a cutting machine and cross-sectioned with as diamond saw in specimens with 2mmX2mmx6mm dimensions, being 2 specimens for each tooth. One of the specimen was taken to a hard tissue microtome were 5µm slabs were obtained and stained with Goldner´s Tricrome. The slabs were analyzed in a Light Microscope with 100 times magnification. In this technique, the mineralized dentin is stained green, the collagen is stained red and the bonding system a pale orange. After, the same specimen was used for micro-Raman analysis. The adjacent specimen was dehydrated in ascendant ethanol sequence and analyzed in scanning electron microscopy. The LM results for SB showed the presence of a large area stained red for both conditions, indicating the presence of exposed or non protected collagen by the bonding system. This area was larger in vivo than in vitro. For CSEB this layer war purple stained and consistent along the interface for both situations, indicating, also, collagen available to react with the staining. For OUB this layer was also purple however, in vivo, this layer was thinner and inconsistent than in vitro. In SEM analysis, SB bonding system presented a porous hybrid layer for both situations. In vitro this layer was thicker and regular along the interface and, in vivo, thinner and irregular. Big differences were observed related to the resin tags. In vivo they were thinner and shorter. For CSEB the hybrid layer was thinner when compared with SB however, more homogeneous and compact along the interface for both situations. Big differences were observed related to the resin tags. In vivo, they were significantly in fewer amounts, shorter and thinner. For OUB in vitro, the hybrid layer was thin, however, homogeneous and with long tags. In vivo, the hybrid layer was very thin, almost undetectable. The resin tags were almost non-existent or bended due to poor polymerization of this system. In micro-Raman analysis for SB showed a greater contribution of the bonding system in the first two micrometers of the interface was detected and, in the rest of the interface, there was few contribution of the resin monomers in the collagen protection. For CSEB the interface was thin (1µm), for both conditions, however, with contribution, in the hybridized complex, of the adhesives components, collagen and mineral. For OUB in vitro, the spectras also indicated the presence of a thin interface, among 1µm, but also, with contribution of the bonding components, collagen and mineral. In vivo, the interface could not be detected by the Raman, for being inexistent, or by the fact to be thinner than the Raman resolution (1µm). After all these analysis of the bonding interface, for both conditions, and with these different bonding systems, it can be concluded that: in vivo condition produced a less-quality interface for all the system. CSEB apparently produced a better-quality interface and OUB the worst. The use of these three techniques together allowed a complete analysis, qualitative and quantitative, of the dentin-bonding interface produced by these three bonding systems, for both situations.
|
33 |
Influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada híbrida e camada de adesivo / The influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the hybrid layer and adhesive layerLobo, Tamile Rocha da Silva 03 September 2013 (has links)
Este estudo avaliou a influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada de adesivo e camada hibrida de uma resina composta à dentina humana, por meio de ensaio de microtração e nanoedentação. Os fatores de variação estudados foram dois sistemas adesivos com estratégias de aplicação distintas Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) e Clearfil SE Bond (Kuraray Co., Osaka, Japan), e ainda foram realizados tratamentos no substrato dentinário utilizando duas concentrações de digluconato de clorexidina sendo estas 2% e 0,2% e grupos controle sem tratamento com clorexidina. As unidades experimentais foram compostas por 48 molares humanos hígidos divididos aleatoriamente em 6 grupos (n=8). Nestes foram aplicados os procedimentos adesivos e realizados os tratamentos de superfície, com clorexidina, previamente aos procedimentos adesivos. Após esta etapa foram confeccionadas as restaurações com espessura de 5mm sobre as superfícies dentinárias. Após 24h de armazenamento em água destilada, os dentes restaurados foram cortados para a obtenção de corpos de prova em forma de palito, com secção transversal de aproximadamente 1mm2. De cada grupo foram selecionados aleatoriamente 5 palitos para o ensaio de dureza. O restante dos palitos viáveis de cada dente foram submetidos ao teste de microtração a uma velocidade de 0,5mm/min até que ocorresse a fratura da interface adesiva. Para o teste de nanoedentação cada um dos 5 palitos referentes aos 6 grupos estudados receberam 10 endentações, sendo 5 na camada de adesivo e 5 na camada hibrida, com distância de 10m entre si. Essas endentações foram realizadas com ultramicrôdurometro (DUH-W211S, Shimadzu Co., Tokyo, Japan). Os dados referentes aos testes de microtração dos seis grupos foram submetidos à análise de variância e teste de Tukey (p<0,05). As médias dos grupos foram: Grupo 1: Clearfil SE controle ( 28.50±0.47); Grupo 2: Adper Scotchbond controle (43.90±7.26); Grupo3: Clearfil SE/ clorexidina 2% (30.43±6.59); Grupo 4: Adper Scotchbond/ clorexidina 2% (39.21±4.69); Grupo 5: Clearfil SE 0,2%( 27.28±7.05); Grupo 6: Adper Scotchbond/ clorexidina 0,2% (35.70±6.43). Na comparação entre as médias dos grupos obteve-se que nenhum dos adesivos testados apresentou alteração na sua resistência de união com o uso do digluconato de clorexidina a 2% ou a 0,2% em análise imediata. Os grupos em que foi utilizado o adesivo Scotchbond apresentaram maiores valores de resistência de união que os grupos em que foi utilizado o sistema adesivo autocondicionante (Clearfil) independente da realização ou não do tratamento de superfície com digluconato clorexidina. Os valores de dureza da camada de adesivo não apresentaram diferenças estatisticamente significantes entre os grupos controle ou entre tratamentos, apenas o grupo com tratamento prévio Clearfil SE/Clorexidina 0,2% apresentou maior valores de dureza na camada de adesivo quando comparado ao grupo Scotchbond com a mesma concentração de clorexidina. Quanto aos valores de dureza da camada híbrida o grupo controle Clearfil SE quando comparado ao grupo Clearfil SE/Clorexidina 2% apresentou menor valor de dureza da camada hibrida. O Scotchbond controle apresentou menor valor de dureza na camada hibrida quando comparado ao grupo Scotchbond com clorexidina a 0,2%. O uso do digluconato de clorexidina nas concentrações 2% e 0,2% em dentina humana, apesar de ter apresentado discretas alterações na dureza da camada hibrida e camada de adesivo, não tiveram a capacidade de afetaram os valores de adesão à dentina dos diferentes adesivos testados. / This study evaluated the influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the adhesive layer and hybrid layer of a composite resin to dentin, using microtensile test and nanoindentation. The variation factors studied were two adhesive systems with different implementation strategies Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) and Clearfil SE Bond (Kuraray Co., Osaka, Japan), and were still held treatments to dentin using two concentrations of chlorhexidine digluconate and these 2% and 0.2% untreated control groups with chlorhexidine. The experimental units were composed of 48 human molars were randomly divided into 6 groups (n = 8). These procedures were applied adhesives and surface treatments performed with chlorhexidine prior to bonding procedures. After this step the restorations were made with 5mm thickness on the dentin surfaces. After 24 hours storage in distilled water, the samples were cut to obtain specimens toothpick shaped cross-section of approximately 1mm2. Each group were randomly selected 5 toothpicks for hardness testing. The remaining viable sticks of each tooth were subjected to microtensile testing at a crosshead speed of 0.5 mm / min until the fracture of the adhesive interface. To test nanohardness each of the five toothpicks referring to six groups received 5 indentations in the adhesive layer and 5 indentations in the hybrid layer with 10m away from each other. These indentations were performed with the equipament DUH-W211S (Shimadzu Co., Tokyo, Japan). The data relating to microtensile test of the six groups were subjected to analysis of variance and Tukey test (p <0,05). The means of the groups were: Group 1: Clearfil SE control (28.50 ± 0:47), Group 2: Adper Scotchbond control (43.90 ± 7.26); Group3: Clearfil SE / 2% chlorhexidine (30.43 ± 6:59), Group 4: Adper Scotchbond / 2% chlorhexidine (39.21 ± 4.69), Group 5: Clearfil SE 0.2% (27.28 ± 07.05), Group 6: Adper Scotchbond / chlorhexidine 0.2% (35.70 ± 6:43). Comparing the means of the groups it was found that none of the adhesives tested showed a change in its bond strength with the use of chlorhexidine gluconate 2% or 0.2% in immediate analysis. The groups that used Scotchbond showed higher bond strength than the groups that used the adhesive system (Clearfil) regardless of performance or not the surface treatment with chlorhexidine digluconate. The hardness values of the adhesive layer did not show statistically significant differences between the control groups or between treatments, the group previously treated with Clearfil SE / Chlorhexidine 0.2% showed higher hardness values in the adhesive layer when compared to Scotchbond with the same concentration of chlorhexidine. As for the hardness of the hybrid layer control group Clearfil SE when compared to Clearfil SE / 2% Chlorhexidine showed lower hardness value of the hybrid layer. The Scotchbond control showed lower hardness value in the hybrid layer when compared to Scotchbond with 0.2% chlorhexidine.The use of chlorhexidine gluconate at concentrations 2% and 0.2% in human dentin, despite having discrete changes in the hardness of the hybrid layer and adhesive layer, did not have the ability to affect the values of adhesion to dentin of different adhesives tested.
|
34 |
Efeito da ciclagem mecânica na resistência de união à dentina humana de uma resina composta associada a dois sistemas adesivos / Effect of mechanical cycling on the human dentin bond strength, of a composite associated to two adhesive systemsBodi, Lucia Helena Vieira Diniz 24 March 2010 (has links)
Diante da grande preocupação atual por sorrisos que também embelezem um rosto, a escolha por materiais estéticos impulsiona pesquisas, que tem como objetivo não só melhorar a qualidade, mas, facilitar o uso desses materiais pelos profissionais. Assim, a proposta desse trabalho foi avaliar a influência da ciclagem mecânica na resistência de união de uma resina composta associada a um sistema adesivo convencional e um autocondicionante à dentina humana hígida por meio de teste de microtração. Para o estudo, foram utilizados 40 terceiros molares humanos hígidos, nos quais as faces oclusais foram lixadas até a obtenção de uma superfície plana com exposição do tecido dentinário. Os dentes foram divididos, aleatoriamente, em quatro grupos (n=10) de acordo com o sistema adesivo utilizado e a realização ou não da ciclagem mecânica: G1 Sistema adesivo Adper Single Bond 2 sem ciclagem mecânica (SB); G2 Sistema adesivo Clearfil SE Bond sem ciclagem mecânica (CF); G3 - Sistema adesivo Adper Single Bond 2 com ciclagem mecânica (SBC); G4 - Sistema adesivo Clearfil SE Bond sem ciclagem mecânica (CFC). Blocos de resina composta foram confeccionados nas superfícies dentinárias após aplicação do sistema adesivo correspondente. Após esse passo, os espécimes dos grupos 3 e 4 passaram por ciclagem mecânica enquanto o restante ficou armazenado em água destilada, mantidos em estufa à 37ºC até o momento do recorte dos espécimes para o teste de microtração. Os corpos de prova foram seccionados em planos perpendiculares à área de união para obtenção de espécimes com área de secção transversal aproximada de 1,0 mm², que foram tracionados, em máquina de ensaios universal, a velocidade de 0,5mm/min. Os resultados de resistência de união foram analisados usando o teste estatístico análise de variância e os modos de fratura foram avaliados em lupa estereoscópica (25X). Não foram encontradas diferenças estatísticas entre os grupos (p<0,05). Pôde-se concluir que não houve influência da ciclagem mecânica nos valores de resistência de união da resina composta associada a ambos os sistemas adesivos utilizados. / In face of an increasing concern about a smile profile that also enhances the overall facial appearance (esthetics), the choosing for more esthetic restorative materials, set in motion researches that have as objective not only the improvement of the quality, but also the easiness of use of these materials by clinicians. The purpose of this in vitro study was to evaluate, by means of a micro tensile test, the influence of the mechanical cycling, on the bond strength of a resin composite, associated to a total etch and a self etching adhesive systems, on the surfaces of sound human dentin. For this study, forty freshly extracted third molars had their oclusal surfaces grounded parallel-flat, until the dentin surfaces were completely exposed. The teeth were randomly divided in four groups (n=10) in accordance with the type of adhesive system and the mechanical cycling treatment, being: G1 Adper Single Bond 2 without mechanical cycling (SB); G2 Clearfill SE Bond without mechanical cycling (CF); G3 - Adper Single Bond 2 with mechanical cycling (SBC); G4 - Clearfill SE Bond without mechanical cycling (CFC).Following the application of the adhesive systems, regarding to each experimental condition, blocks of Z-250 composite were built, on the dentinal surfaces. After this step, the G3 and G4 specimens were submitted to the mechanical cycling test, while the G1 and G2 specimens were kept stored in distilled water at 37°C, until the moment of sectioning for the microtensile test. The specimens were seccionated perpendicularly to their adhesive area to obtain beam shaped specimens with approximate cross-section area of 0.8mm2, which were readily submitted to the microtensile test in a universal test machine with a crosshead speed of 0.5mm/min. The fracture modes were evaluated by means of a stereoscopic microscope (25x). There were no significant statistical differences founded in the bond strength values among the tested groups.
|
35 |
Estudo in vitro da influência da contaminação com Streptococcus mutans e da descontaminação com digluconato de clorexidina 2% na resistência de união de sistemas adesivos à dentina humana / In vitro study of the influence of Streptococcus mutans contamination and 2% chlorhexidine digluconate disinfection on bond strength of adhesive systems to human dentinBengtson, Camilla Regina Galvao 21 June 2007 (has links)
O objetivo desse trabalho foi avaliar, in vitro, a influência da contaminação com Streptococcus mutans e da desinfecção com solução de digluconato de clorexidina 2% na adesão de dois sistemas adesivos (um sistema adesivo com condicionamento ácido prévio e um sistema adesivo autocondicionante) à dentina de molares humanos. Para o estudo, foram utilizados 80 terceiros molares humanos hígidos, com a face oclusal lixada até a exposição de uma superfície plana de dentina. Os dentes foram divididos aleatoriamente em 8 grupos (n=10) de acordo com o sistema adesivo utilizado e tratamento superficial realizado: G1 ? Controle Single Bond 2 (SB); G2 ? Controle Clearfil SE Bond (SE); G3 ? Desinfecção com clorexidina SB; G4 ? Desinfecção com clorexidina SE; G5 ? Contaminação com Streptococcus mutans SB; G6 ? Contaminação com Streptococcus mutans SE; G7 ? Contaminação com Streptococcus mutans e desinfecção com clorexidina SB e G8 ? Contaminação com Streptococcus mutans e desinfecção com clorexidina SE. Corpos de prova em resina composta foram confeccionados nas superfícies tratadas e os dentes foram armazenados em água destilada à 37ºC por 24 horas. As amostras foram seccionadas verticalmente obtendo-se espécimes com área de secção transversal de aproximadamente 0,8mm2, que foram tracionados a velocidade de 0,5mm/min em máquina de ensaios universal. Cinco espécimes de cada grupo tiveram a interface adesiva analisada em microscopia eletrônica de varredura (MEV). Os resultados de resistência de união foram analisados usando os testes estatísticos ANOVA e Tukey (p<0,05). Os modos de fraturas foram avaliados por meio de lupa esteroscópica (25X). Discos de dentina foram obtidos de 6 dentes adicionais, para observação em MEV das superfícies submetidos aos mesmos tratamentos realizados para o teste de microtração. Não foram encontradas diferenças estatísticas entre os grupos controles (G1 = 31,52 ± 6,24 e G2 = 42,88 ± 2,31), o tratados com clorexidina (G3 = 34,41 ± 6,92 e G4 = 40,14 ± 2,91) e os grupos que foram submetidos à contaminação com Streptococcus mutans e descontaminação com clorexidina (G7 = 31,12 ± 5,31 e G8 = 39,09 ± 3,86). Os grupos submetidos à contaminação com Streptococcus mutans que não foram descontaminados antes da aplicação dos sistemas adesivos tiveram resultados significantemente menores que os grupos estéreis e descontaminados (G5 = 23,61 ± 7,13 e G6 = 33,15 ± 3,35). O sistema adesivo Clearfil SE Bond apresentou valores de resistência de união significantemente maiores que o sistema adesivo Single Bond 2, independente do tratamento da superficial dentina. Pôde-se concluir que a contaminação in vitro com Streptococcus mutans comprometeu a adesão dos dois sistemas adesivos e a solução de digluconato de clorexidina 2% foi capaz de eliminar a contaminação, restabelecendo os valores de resistência de união obtidos com o substrato estéril. / The purpose of this study was to evaluate, in vitro, the influence of Streptococcus mutans contamination and 2% chlorhexidine digluconate disinfection on the bond strength of two adhesive systems (an etch-and-rinse system and a self-etch system) to human dentin molars. Flat dentinal surfaces were prepared in 80 extracted human third molars. Teeth were randomly divided into 8 groups (n=10) according to the adhesive system and the dentin superficial treatment: G1 ? Single Bond 2 (SB) control; G2 ? Clearfil SE Bond (SE) control; G3 ? Desinfection with chlorhexidine SB; G4 ? Desinfection with chlorhexidine SE; G5 ? Contamination with Streptococcus mutans SB; G6 ? Contamination with Streptococcus mutans SE; G7 ? Contamination with Streptococcus mutans and desinfection with chlorhexidine SB e G8 ? Contamination with Streptococcus mutans and desinfection with chlorhexidine SE. Composite resin blocks were built up over treated surfaces, and teeth were then stored in water at 37 degrees C for 24 h. Samples were vertically sectioned, obtaining specimens with 0.8mm2 cross-sectional area. Specimens were stressed in tension at 0.5 mm/min crosshead speed. Five specimens of which group were observed under SEM. Bond strength results were evaluated using ANOVA and Tukey tests(p<0.05). The modes of failures were verified using optical microscope (25X). Dentin disks were obtained from 6 additional teeth treated in the same manner for observation under SEM. No statistically significant differences of bond strength values were found between controls groups (G1 = 31,52 ± 6,24 e G2 = 42,88 ± 2,31), groups treated with chlorhexidine (G3 = 34,41 ± 6,92 e G4 = 40,14 ± 2,91) and groups contaminated with Streptococcus mutans (G7 = 31,12 ± 5,31 e G8 = 39,09 ± 3,86). The groups contaminated with Stretococcus mutans that were not desinfected before the adhesive systems application presented significantly lesser results than sterile or desinfected groups (G5 = 23,61 ± 7,13 e G6 = 33,15 ± 3,35). Clearfil SE Bond presented significant high bond strenght values than Single Bond 2, independent of dentin superficial treatment. It was concluded that the contamination in vitro with Streptococcus mutans reduced bond strength of the two adhesives systems and 2% chlorhexidine digluconate solution eliminated the contamination, reestablishing the bond strength values gotten with sterile substrates.
|
36 |
Avaliação do grau de sorção, solubilidade e taxa de conversão de sistemas adesivos irradiados com laser de diodo / Evaluation of water sorption/solubility and conversion degree of the adhesive systems irradiated with diode laserBrianezzi, Leticia Ferreira de Freitas 03 March 2015 (has links)
O LASER tem sido utilizado previamente a polimerização de sistemas adesivos em dentina como uma estratégia para melhorar as suas propriedades. O objetivo deste estudo foi investigar o efeito do LASER de diodo na sorção (SB), solubilidade e grau de conversão das principais categorias de sistemas adesivos. Quatro sistemas adesivos foram testados: convencional de 3 passos (Adper™ Scotchbond™ Multi-Purpose-MP), convencional de 2 passos (Adper™ Single Bond 2-SB), autocondicionante de 2 passos (Clearfil™ SE Bond-SE) e o sistema universal (Adper™ Single Bond Universal-SU). O adesivo fluido foi dispensado numa matriz de teflon (6.0 x 6.0 x 1 m),irradiado com laser de diodo com 970 nm e polimerizado com luz LED. Para o teste de sorção e solubilidade foram preparados espécimes em uma matriz de teflon quadrada (n=10): MP, SB, SE e SU (sem irradiação) e MP-L, SB-L, SE-L e SU-L (grupos com irradiação). Essa mensuração foi monitorando a mudança de massa depois dos ciclos de armazenamento de desidratação/ água. Para o grau de conversão, espécimes similares eram preparados e divididos 8 grupos iguais (n=5), utilizando a espectroscopia infravermelho transformada de Fourrrier (FTIR) com reflectância total atenuada (ATR). Cada espécime era comprimido contra o cristal do ATR (diamante/ZnSe) com um pressão micrométrica. As amostras não polimerizadas (≈3.0μL, n=5) de cada adesivo era escaneada para calcular o grau de conversão. Para sorção (μg/mm3) houve diferença estatisticamente significante para ambos os fatores (p<0.05) sem interação entre eles SB> SU> MP> SE. Para a solubilidade (μg/mm3), somente o fator adesivo foi significante (p<0.05): SB>SU>MP=SE. A irradiação do LASER antes da polimerização aumentou o grau de conversão dos sistemas adesivos SBL> MP-L> SE-L> MP> SB> SE> SU-L> SU. A irradiação aumentou a sorção, mas não afetou a solubilidade dos sistemas adesivos. Além disso, a irradiação com LASER de diodo melhorou o grau de conversão de três sistemas adesivos testados. / Laser irradiation has been used over the dentin bonding systems (DBS) prior to polymerization as a strategy to improve their properties. The aim of this study was to investigate the effect of diode laser on water sorption (WS), solubility (WSB) and conversion degree (DC) of main categories of DBS. Four bonding agents were tested: 3-step total-etch (Adper™ Scotchbond™ Multi-Purpose-MP), 2-step total-etch (Adper™ Single Bond 2-SB), 2-step self-etch Clearfil™ SE Bond-SE) and universal system (Adper™ Single Bond Universal-SU). The fluid DBSs were dispensed into Teflon molds (6.0 x 6.0 x 1mm), irradiated with a 970 nm diode laser and then polymerized with a LED curing unit. For WS/WSB tests, square-shaped DBS were prepared (n=10): MP, SB, SE and SU (control groups/ no laser irradiation) and MP-L, SB-L, SE-L and SU-L (laser irradiated groups). WS/WSB were measured by monitoring the mass changes after dehydration/water storage cycles. For DC tests, similar square-shaped specimens were prepared and assigned into eight similar groups (n=5), using Fourier transform infrared spectroscopy (FT-IR) with attenuated total reflectance (ATR). Each cured specimen was compressed against the ATR crystal (diamond/ZnSe) with a micrometric, low-pressure clamp. Uncured resin samples (≈3.0μL, n=5) of each adhesive were also scanned for DC calculation. For WS (μg/mm3), both factors were statistically significant (p<0.05), without interaction between them SB>SU>MP>SE. For WSB (μg/mm3), only DBS was a significant factor (p<0.05): SB>SU>MP=SE. Laser irradiation immediately before photopolymerization has increased the DC (%) of the tested adhesives: SB-L> MPL> SE-L> MP> SB> SE> SU-L> SU. Irradiation with diode laser improved the conversion degree of all tested dentin bonding systems. Furthermore the diode laser increased the sorption, but did not affect their water solubility.
|
37 |
Influência da solução de clorexidina a 2% na resistência adesiva de pinos de fibra de vidro em raízes bovinas: acompanhamento imediato, 6 meses e 1 ano / 2% chlorhexidine influence on fiber posts bond strength to bovine roots: immediate, 6-month and 1-year-agingSilva, Luciana Mendonça da 04 July 2013 (has links)
Este trabalho teve como objetivo avaliar a influência da solução de clorexidina a 2% na resistência adesiva de pinos de fibra de vidro cimentados com cimento resinoso convencional utilizando três diferentes sistemas adesivos (2 convencionais e 1 autocondicionante), no período de 7 dias, 6 meses e 1 ano. Foram selecionadas 180 raízes bovinas, que foram tratadas endodonticamente e divididas em 6 grupos (n=30): MP, sistema adesivo (SA) convencional de 3 passos (ScotchBond Multi Uso); SB, SA convencional de 2 passos (Single Bond); SE, SA autocondicionante de 2 passos (Clearfil SE Bond); MP-CHX, SB-CHX e SE-CHX, com aplicação da clorexidina (CHX). Em todos os grupos, o pino de fibra de vidro Exacto foi cimentado com cimento resinoso dual RelyX ARC. Cada grupo foi dividido em 3, de acordo com o período experimental, 7 dias, 6 meses e 1 ano (n=10). Após a obtenção de fatias com 1mm de espessura, os espécimes foram submetidos ao teste de push-out (100kg, 0,5mm/min). Os tipos de falhas foram analisados em microscópio ótico de luz (40x) e classificados em: adesiva cimento/dentina; adesiva cimento/pino; coesiva em dentina ou cimento, e mista. Os valores, convertidos em MPa, foram analisados pelo teste ANOVA a 4 critérios e teste de Tukey para comparação das médias, com nível de significância de 5%. Não houve diferença estatística com o uso da CHX para os SAs convencionais testados, nos períodos de 7 dias, 6 meses e 1 ano (p>0,05). Dentre os SA, o MP foi o que se manteve constante com ou sem CHX (p>0,05). Houve diminuição de resistência adesiva no terço cervical, em 1 ano, e no terço apical em 7 dias do SE-CHX (p<0,05). Pode-se concluir que o uso da CHX pareceu não interferir na resistência adesiva dos SAs testados, exceto para o SA autocondicionante, em 7 dias e 1 ano. / The aim of this work was to evaluate the 2% chlorhexidine influence on fiber posts bond strength luted with a resin cement, with three different dentin bonding systems (2 etch-and-rinse and 1 self-etching), with 7-day, 6-month and one-year-aging. One hundred and eighty bovine roots were endodontically treated and randomly assigned to 6 groups (n=30): MP, three-step etch-and-rinse dentin bonding system (DBS) (ScotchBond Multi Uso); SB, two-step etch-and-rinse DBS (Single Bond); SE, twostep self-etching DBS (Clearfil SE Bond); MP-CHX, SB-CHX and SE-CHX, with chlorhexidine (CHX) application. Exacto fiber posts were luted with dual cure resin cement RelyX ARC in all groups. Each group was divided in three, according to aging (n=10). After obtainning 1mm-thick slices, push-out test was carried out (100kg, 0,5mm/min). Failure modes were assessed under light microscopy (40x) and classified in: adhesive to dentin; adhesive to post; cohesive in dentin or cement, and mixed failure. Values were converted to MPa and analyzed by 4-way ANOVA and Tukeys test for multiple comparisons, at 5% significance level. There was no difference with the use of CHX for tested etch-and-rinse DBSs, after 7-day, 6-month and one-year-aging (p>0,05). Among DBSs, MP presented constant values (p>0,05). SE-CHX presented significant lower bond strength values on the cervical third, at one year, and apical third at 7 days (p<0,05). It can be concluded that CHX use seemed not to interfere bond strength values of all materials tested, except for the self-etch DBS, after 7 days and one year-aging.
|
38 |
Efeito da solução de clorexidina a 2% na adesão de um sistema restaurador adesivo à dentina previamente erodida com refrigerante tipo cola regular e light / Effect of 2% chlorhexidine solution on adhesive bond strength to eroded dentin by regular and light cola drinksCasas Apayco, Leslie Caroll 28 June 2013 (has links)
Os refrigerantes são potentes agentes erosivos que podem provocar perda de estrutura dentária e requerer o tratamento restaurador adesivo, dependendo do grau de comprometimento. Pelas diferentes propriedades apresentadas, estas bebidas podem afetar a adesão à dentina de diferentes formas. Este estudo teve como objetivo avaliar a resistência de união (RU) em dentina erodida tratada com solução de clorexidina a 2%. Sessenta terceiros molares tiveram a superfície dentinária do terço oclusal exposta e foram distribuídos em 3 grupos, de acordo com o protocolo erosivo: controle, sem desafio (C), desafio erosivo com Coca-Cola (CC) e desafio erosivo com Coca-Cola Light (CL). As ciclagens erosivas foram por ciclos de 5-min de imersão 3x/dia durante 5 dias. Em seguida, metade dos dentes foi tratado com solução de clorexidina a 2% (1,5ul) e o restante com água deioinizada (1,5ul) e o processo adesivo realizado com Adper Single Bond 2® e resina composta Filtek Z350®. Os espécimes foram mantidos em estufa a 37oC por 24 horas. Após esse período, todos os espécimes foram seccionados em palitos (0,80mm2 a 1mm2). Um terço dos palitos obtidos de cada grupo foi testado imediatamente (I-24 h) pelo teste de microtração. Os espécimes remanescentes foram envelhecidos em saliva artificial por 6 meses (6m) e 1 ano (1a) antes do teste. Os dados obtidos da microtração foram analisados por meio dos testes de ANOVA a três critérios e Tukey (p<0,05). O modo de fratura foi analisado e classificado em adesivo, misto e coesivo em dentina ou resina composta. Simultaneamente, uma fatia (mesiodistal) de cada espécime foi analisado por microscopia confocal para análise da interface resina/dentina e formação de tag nos tempos de envelhecimento. Os valores médios de resistência adesiva (MPa ± dp; 24 horas/6 meses /1 ano) foram: C(38,57 ± 15,36/26,67 ± 19,37/12,21 ± 11,24); C-Chx2%(41,93 ± 9,97/31,12 ± 17,02/11,86 ± 10,4); CC(21,80 ± 7,09/8,33 ± 10,71/4,70 ± 9,04); CC-Chx2%(19,85 ± 7,87/24,32 ± 11,7/6,19 ± 12,37); CL (22,70 ± 9,63/10,25 ± 15,6/4,93 ± 5,54); CL-Chx 2% (22,40 ± 7,34/20,94 ± 14,68/16,05 ± 13,91). A resistência de união à dentina erodida foi significativamente inferior ao do grupo controle, independentemente do tempo de armazenagem dos espécimes. Tanto a dentina normal e erodida, apresentaram redução dos valores de resistência de união ao longo do tempo. Apesar de os espécimes tratados com solução de clorexidina a 2% manterem os valores de resistência de união por 6 meses, eles reduziram após 1 ano. De acordo com as imagens por microscopia confocal, não houve diferenças observadas na qualidade geral da camada híbrida e formação de tags entre os grupos. A solução de digluconato de clorexidina a 2% pode ser uma alternativa para manter a estabilidade da interface de união adesiva ate os 6 meses. A resistência de união mais estável à dentina erodida por Coca-Cola Light comparada à dentina erodida por Coca-Cola ao longo do tempo, sugere a implicação de suas propriedades na adesão. / Soft drinks are potent erosive agents, which can provoke loss of dental structure and require adhesive restorative treatment, depending on the compromising level. Due to the different properties, these beverages can affect bonding to dentin in different manners. The aim of this study was to evaluate the bond strength (BS) to eroded dentin treated with 2% chlorhexidine solution. Sixty third human molars had their oclusal thirds removed to expose flat dentin and were divided into three groups, according to erosive protocol: Control (C) with no surface treatment, erosive challenge with Regular Coke (CC), erosive challenge with Light Coke (CL). The erosive challenge was performed by cycles of 5-min immersions, 3x/day during 5 days. After that, half of the teeth were treated with 2% chlorhexidine solution (1,5ul) and the remaining with deionized water (1,5ul) before adhesion procedure with Adper Single Bond 2® and FiltekTMZ350®. Specimens were stored at 37oC in deionized water for 24 hours. After this period, all specimens were sectioned into sticks (≈0.81 mm2 to 1mm2). A third of the specimens were tested immediately (I-24 h), for microtensile test. The remaining sticks aged in artificial saliva for 6 months (6m) and 1 year (1y) before testing. The failure mode was analyzed and classified as adhesive, mixed and cohesive in dentin or resin. Bond strength data was analyzed by three-way ANOVA and Tukey tests (p<0.05). Simultaneously, one slice (mesial-distal) of each specimen was analyzed by confocal microscopy for analysis of the interface resin/dentin and tag formation over the aging time. Means and standard-deviation (MPa) of each group (I, 6m and 1y) were: C (38.57±15.36, 26.67±19.37, 12.21±11.24), C-Chx 2% (41.93±9.97, 31.2±17.02, 11.86±10.4), CC (21.80±7.09, 8.33±10.71, 4.70±9.04), CC-Chx 2% (19.85±7.87, 24.32±11.7, 6.19±12.37) CL (22.70±9.63, 10.25±15.6, 4.93±5.54) and CL-Chx 2% (22.40±7.34, 20.94±14.68, 16.05±13.91). Adhesive and/or mixed failures were frequently observed in all specimens. Bond strength of eroded dentin specimens was lower than of the normal dentin specimens, for all testing times. Both normal and eroded dentin showed decrease on µTBS values with time. Although the specimens treated with 2% chlorhexidine solution maintained the bond strength values for 6 months, they reduced significantly, after 1 year. after this period the bond strength values went down. According to confocal microscopy images, no difference in the overall quality of hybrid layer and tags formation among groups was observed. The use of 2% chlorhexidine solution could be an alternative to maintain the stability of bonding interface. More stable bonding strength to eroded dentin with Coca-Light over time, compared to dentin eroded by Regular Cola suggests the implication of their properties on bonding.
|
39 |
Avaliação da interface de adesão à dentina humana de um sistema restaurador adesivo à base de silorano, em cavidades de Classe I, analisados por teste de microtração e microscopia óptica / Evaluation of the interface of a silorane based restorative system to dentin of Class I cavities by microtensile bond strength test and optical microscopyEspinoza, Carlos Andrés Villavicencio 24 May 2013 (has links)
Este estudo teve como objetivo a análise da interface de adesão à dentina humana, de um sistema restaurador adesivo à base de silorano. Foram confeccionadas cavidades com 4mm X 3mm X 5mm em 40 molares humanos extraídos divididos em 4 grupos aleatoriamente: Grupos SB e SB-6m: sistema adesivo (Adper™ Single Bond) + resina composta (Filtek Z250); Grupos P90 e P90-6m: sistema adesivo (P90 System Adhesive) + resina composta (Filtek P90™). Em todos os grupos, as restaurações foram inseridas em 4 incrementos oblíquos. Após a restauração, os dentes foram seccionados em fatias de 0,8mm de espessura em uma máquina de cortes com um disco de diamante. Uma fatia de cada dente foi separada aleatoriamente para análise em microscópio óptico para verificação de fendas na interface adesiva. As demais fatias foram seccionadas em palitos (0,8mm X 0,8mm) para os testes de microtração em uma máquina de ensaios universal EMIC. Os e dos grupos SB e P90 permaneceram em água deionizada em estufa a 370C por 24 horas e os grupos SB-6m e P90-6m permaneceram em água deionizada em estufa a 370C por um período de 6 meses. Os resultados de resistência de união foram submetidos à análise de variância a 2 critérios ANOVA e a presença de fendas internas foi analisada pelo testeChi-quadrado. Houve diferença estatisticamente significante na resistência de união entre os materiais (p>0,05) e tempo de armazenagem. Quanto à presença de fendas internas, foi evidenciada sua presença em todos os grupos, sem diferença etatisticamente significante entre eles (p>0,05). Conclui-se que não houve diferença entre os sistemas restauradores á base de Bis-GMA e de silorano os 2 períodos avaliados (24h e 6 meses). / This study aimed to analyse the adhesive interface to human dentin of a silorane based adhesive system. Cavities were fabricated with 4.0 mm X 3mm X 5mm in 40 extracted human molars randomly divided into 4 groups: Groups SB and SB-6m: adhesive system (Adper™ Single Bond) + composite (Filtek Z250); Groups P90 and P90- 6m: adhesive system (P90 System Adhesive) + composite (Filtek™ P90). In all groups, the restorations were inserted in 4 oblique increments. After 24 hours, teeth were sectioned buccolingually into 0.8mm slices with diamond saw. One slice of each tooth was randomly separated for microscope analysis. The other slices were sectioned into 0.8mm X0.8mm sticks for microtensile tests in a universal testing machine EMIC. Sticks of groups SB and P90 remained in deionized water at 370C C for 24 hours and sticks of groups SB-6m and P90-6m remained in deionized water at 370C for a period of six months. After storage period . The results of bond strength were analysed by Two-way ANOVA and the presence of internal gaps was analyzed by chi-square test. There was no significant difference in bond strength between materials (p> 0.05) and storage time. Regarding the presence of internal rifts, their presence was evident in all groups, with no statistically significant difference between them (p> .05).
|
40 |
Efeito do modo de aplicação no desempenho de adesivos autocondicionantes simplificados à dentina / Effect of application mode on the performance of simplified self-etch adhesives to dentinSerrano, Alexandra Patricia Mena 23 March 2010 (has links)
Made available in DSpace on 2017-07-24T19:22:10Z (GMT). No. of bitstreams: 1
Alexandra Serrano.pdf: 5795461 bytes, checksum: d55b3e436e3ca0014b131ab661ce7049 (MD5)
Previous issue date: 2010-03-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was to evaluate the effect of different application modes on the immediate and 6-month resin-dentin bond strength and silver nitrate uptake. Three one-step self-etch adhesive systems (One Coat 7.0 [OC], Coltène Whaledent; Clearfil S3 Bond [CS], Kuraray and FuturaBond NR [FB], Voco) were applied in a flat superficial dentin surface of thirty human molars under slight [S] or vibratory [V] application modes. Composite build-ups (Opallis, FGM) were constructed incrementally. After water storage at 37 °C for 24 h, teeth were sectioned to obtain sticks with cross-sectional area of 0.8 mm2 to be tested in tension (0.5 mm/min) either immediately [IM] or after 6 months [6M] of water storage. Two bonded sticks from each tooth at each storage time were immersed in a 50% (w/v) solution of silver nitrate (24 h), photo-developed (8 h) and analyzed under SEM. The silver nitrate uptake was measured using the ImageTool 3.0 software. The data from each adhesive were analyzed by two-way ANOVA and Tukey’s test (α = 0.05). The adhesives OC and CS showed higher resin-dentin bond strength values and lower silver nitrate deposition in the immediate time and vibratory application groups. For FB, no significant difference was observed between the two modes of application in the respective storage periods. The vibratory application mode can improve the resin-dentin bonds, reduce the silver nitrate uptake and retard the degradation of the resin-dentin bonds of Clearfil S3 Bond and One Coat 7.0 adhesives. / O objetivo deste estudo foi avaliar o efeito da aplicação vibratória de adesivos autocondicionantes simplificados na resistência de união à dentina e nanoinfiltração, tanto no tempo imediato como após 6 meses de armazenamento em água. A superfície oclusal de trinta terceiros molares foi desgastada até obtenção de uma superfície plana de dentina. Três sistemas adesivos autocondicionantes de 1 passo (One Coat 7.0 [OC], Coltène Whaledent; Clearfil S3 Bond [CS], Kuraray e FuturaBond NR [FB], Voco) foram aplicados de forma suave (SU) ou vibratória (VB) (n=5). Após a construção de coroas de resina composta (Opallis, FGM), os espécimes foram armazenados durante 24 h em água destilada a 37 °C. Ao término deste período os espécimes foram cortados longitudinalmente nas direções “x” e “y” para conseguir palitos com seção transversal de 0,8 mm2. Os espécimes foram testados sob tração (0,5 mm/min) no tempo imediato [IM] ou após 6 meses de armazenamento em água [6M]. Dois espécimes de cada dente nos respectivos períodos de armazenamento foram imersos por 24 h em uma solução 50% por peso, revelados (8 h) e analisados em microscopia eletrônica de varredura. A quantidade de penetração de nitrato de prata na interface adesiva foi medida no software ImageTool 3.0. Os dados de cada adesivo provenientes de cada teste foram submetidos a uma análise de variância de dois fatores (Forma de Aplicação vs. Tempo) e teste de Tukey (α=0,05) para contraste das médias. Maiores valores de resistência de união e menor deposição de nitrato de prata foram observados no tempo imediato e nos grupos de aplicação vibratória para os adesivos OC e CS. FB apresentou baixos valores de resistência de união independente do tipo de aplicação. Pode-se concluir que a aplicação vibratória pode aumentar os valores de resistência de união dos adesivos One Coat 7.0 e Clearfil S3 Bond retardando o processo de degradação destas interfaces.
|
Page generated in 0.1057 seconds