• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2148
  • 1953
  • 282
  • 269
  • 105
  • 103
  • 86
  • 75
  • 50
  • 28
  • 28
  • 28
  • 28
  • 28
  • 28
  • Tagged with
  • 5998
  • 1162
  • 851
  • 575
  • 537
  • 503
  • 444
  • 408
  • 394
  • 388
  • 386
  • 375
  • 371
  • 323
  • 297
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Electron Dose Distribution Near Tissue-Bone Interfaces

Bialobzyski, Philip 02 1900 (has links)
Recent advances in immunological technology have made it feasible to investigate the diagnosis and treatment of cancer with radiolabelled anti-tumor antibodies. The red bone marrow and endosteal cells of bone are likely to be the dose limiting tissues for systemic applications. Therefore, it is of clinical importance to quantitate their dose. Due to the small size of the marrow cavities in trabecular bone, it is experimentally difficult to measure the electron dose distribution. A computer simulation of electron transport is used to determine the dose distribution inside the marrow cavity. Electrons are backscattered more from bone than soft tissue, thereby increasing the dose to the radiosensitive endosteum and red bone marrow. A point source of beta activity (204Tl and 147pm) sandwiched between planar slabs of bone and red bone marrow equivalent plastics and 7LiF thermoluminescent dosimeters (TLD's) were used to determine the dose increase at various distances from the interface. Experimental results were compared with calculations using the Monte Carlo codes EGS (Electron Gamma Shower, SLAC) and CYLTRAN (Oak Ridge National Laboratory). The planar geometry was used as a benchmark geometry to compare the computer codes with experiment. After checking the accuracy of the codes for low energy electron transport, ACCEPT, a version of CYLTRAN, was used to investigate the radiation dose increase due to a point source of beta activity inside a polystyrene sphere bounded by aluminum. Spheres with radii of 200 and 500 microns were used. / Thesis / Master of Science (MS)
92

The significance of bone marrow examination in certain diseases of the bovine and canine

Griffing, William James January 2011 (has links)
Digitized by Kansas State University Libraries
93

Osteogenesis in porous biomaterials for bone regeneration

Midha, Swati January 2012 (has links)
This thesis focuses on evaluating the osteogenic potential of two synthetic bone graft materials either in vitro and/or in established rodent bone defect models.
94

Role of type 2 cannabinoid receptor in bone metabolism

Sophocleous, Antonia January 2009 (has links)
Cannabinoid receptors play an important role in regulating bone mass and bone turnover. Studies in our laboratories have shown that young mice lacking type 1 cannabinoid receptor (CNR1-/-) had increased bone mass and were resistant to ovariectomy-induced bone loss. Other workers have reported that type 2 cannabinoid receptor knockout mice (CNR2-/-) develop age-related osteoporosis. The aim of this PhD thesis was to further investigate the role of CNR2 in bone metabolism in vitro and in vivo, using genetic and pharmacological approaches. This study showed that CNR2-/- mice had normal bone mass and bone turnover at 3 months of age, but following ovariectomy, CNR2-/- mice were partially protected from bone loss, because of a mild defect in osteoclast formation and bone resorption. In keeping with this, studies in vitro showed that RANKL-stimulated bone marrow cultures from CNR2-/- mice had fewer osteoclasts than cultures from wild type littermates. The CNR2-selective antagonist/inverse agonist AM630, inhibited osteoclast formation in wild type bone marrow cultures in vitro and prevented ovariectomy-induced bone loss in wild type mice in vivo. In contrast, osteoclast cultures from CNR2-/- mice were resistant to the inhibitory effects of AM630 at low concentrations and CNR2-/- ovariectomised mice did not respond to its protective effects at low doses, consistent with a CNR2- mediated effect. These results indicate that CNR2 regulates bone loss under conditions of increased bone turnover, such as ovariectomy, by affecting osteoclast differentiation and function. CNR2-deficient mice developed accelerated age-related osteoporosis and by 12 months of age they had a significant reduction in osteoblast numbers and bone formation, whereas osteoclast numbers remained comparable to wild type littermates. In agreement with this, osteoblasts derived from bone marrow of CNR2-/- mice had reduced PTHstimulated alkaline phosphatase activity and ability to form bone nodules, when compared with wild type cultures. The CNR2-selective agonist, HU308, stimulated bone nodule formation in wild type calvarial osteoblast cultures in vitro and reversed ovariectomy-induced bone loss in wild type mice in vivo. HU308 had blunted effects on bone nodule formation in cultures from CNR2-/- mice and no significant effects on ovariectomy-induced bone loss in CNR2-/- mice, indicating a CNR2-mediated effect. These studies demonstrate that CNR2 protects against age-related bone loss by mainly enhancing osteoblast differentiation and bone formation. In conclusion, type 2 cannabinoid receptors protect from bone loss by maintaining bone remodelling at balance. In addition, type 2 cannabinoid receptor agonists show evidence of anabolic activity, whereas antagonists/inverse agonists show evidence of antiosteoclastic activity in vitro and in vivo.
95

Digging into bone : investigative studies into silicate-substituted hydroxyapatite, collagen molecules and bone properties

Harden, Fiona J. January 2014 (has links)
Investigations into silicate-substituted hydroxyapatite (Si-HA) were performed. The aqueous precipitation method produced phase pure Si-HA with modi cations to the method causing impurities in the material. A novel study using Raman spectroscopy followed the behaviour of the silicate ions and provided a new interpretation regarding silicate substitution. The silicate ions created interactions with hydroxyl ions, initially, which reduced upon sintering of the material. As the silicate ions do not behave inde- pendently in the HA structure initially, suggests that these interactions may contribute to the bioactivity of Si-HA. Also industrial aspects of Si-HA were investigated regarding the silicate reagent (TEOS). A small di erence of 1% in the percentage concentration of TEOS was not negligible and caused a decrease in the amount of silicate substituted into HA. Di erent brands and grades of TEOS did produce Si-HA with similar structural properties. Therefore, a variety of brands and grades of TEOS can be used and thus the most cost e ective choice can be made. The rst analytical investigations into the molecular arrangement of fully mineralised osteoarthritic (OA) and osteoporotic (OP) bone were performed through small angle neutron scattering (SANS) studies. This study provided a description for the molecular arrangement of collagen molecules, along the lateral plane, regarding the molecular di- ameter and the packing of these molecules into the bril by the development of a model based on SANS theory. The collagen molecules behave like a 2-dimensional liquid-like system. Through the development of the model, the rst written solution for the struc- ture factor for a system of hard-disks was stated. This study provided an understanding into how collagen molecules are arranged in OA and OP bone. Also, compositional studies iterated possible di erences between the organic content of OA and OP bone. Thus the organic content of bone may play a role in the bone disorders.
96

Bioactive scaffolds for potential bone regenerative medical applications

Sharp, Duncan McNeill Craig January 2011 (has links)
Fracture non-unions and bone defects represent a recalcitrant problem in the field of orthopaedic surgery. Although the current gold-standard treatment, autologous bone grafting, has a relatively high success rate, the technique is not without serious problems. The emerging field of regenerative medicine may have the potential to provide an alternative treatment. One promising strategy involves the delivery of both cells and multiple growth factors with different release profiles. A range of scaffolds was developed from Poly( -caprolactone) (PCL), Poly(lactideco- glycolide) (PLGA), and two blends of PCL (Mn 42,500) and PLGA. The scaffolds were manufactured utilising a novel modified fused deposition modelling system, using polymer/dichloromethane solutions. The scaffolds were found to have pore sizes suitable for bone regenerative medical applications (373±9.5 μm in the Ydirection and 460±13 μm in the X-direction). However, the scaffolds were found to be only 52±3 μm in height. This means that the two-layer scaffolds were relatively flat. This was undesirable, as direct control of the complete 3D geometry was the favoured strategy, though it may not be a necessary requirement. Five scaffold coatings were also developed from alginate, chitosan (crosslinked using sodium hydroxide or tripolyphosphate), Type-I collagen and Type-A gelatin. The scaffold coatings were screened in vitro for their cell-compatibility with human marrow stromal cells (hMSCs), human osteoblasts and MG63 cells. This was assessed using an assay for cell death, and assessing total cell counts. From these studies, Type-I collagen was found to be the optimum coating. For hMSCs, their death rates were found to be 19.1±6.3% for alginate, 5.3±3.6% and 2.9±1.4% for chitosan crosslinked with tripolyphosphate and sodium hydroxide respectively, compared to 0.11±0.07% for Type-I collagen, and 0.15±0.13% and 0.16±0.12% for 0.1% and 0.2% gelatin respectively. Type-I collagen was found to be the most cellcompatible coating, as it was consistently associated with higher cell counts than Type-A gelatin. Similarly, PCL scaffolds vacuum dried for 1 hr were found to be cell-compatible. No detectable clinically significant difference was found in either total cell counts, or the proportion of cell death in; hMSCs exposed to PCL scaffolds processed with dichloromethane, hMSCs either exposed to scaffolds known to be biocompatible, or hMSCs cultured in the absence of scaffolds. When cell morphology was compared, scaffolds vacuum dried for 1 hr or more were found to have a similar morphology to the cells cultured in the absence of scaffolds. It was therefore concluded that a vacuum drying time of 1 hr was sufficient for cell-compatibility. The scaffold materials were screened both for their encapsulation efficiencies and release characteristics using the model drug, methylene blue. The encapsulation efficiency was found to be both relatively high and consistent for both Mn 42,500 and 80,000 PCL as well as PCL:PLGA 66:33, at 71±6%, 71±5%, and 78±10% respectively, relative to the low efficiencies recorded for both PCL:PLGA 66:33 and PLGA: 57±5% and 38±10% respectively. The release rate of methylene blue from PCL (Mn 42,500), was found to be relatively slow, controlled, and consistent between batches (between 21±2% and 20±3% released in the first 24 hr). Despite the release rate being consistent for PCL (Mn 80,000), the release rate was thought to be too high, since between 29±3% and 39±5% of the test compound was released in the first 24 hr period. The release rate of methylene blue from the PCL/PLGA blends (between 17±2% – 30±7% and 18±4% – 31±6% in the first 24 hr) and PLGA (between 7.1±3.4% – 9.3±2.9% in the first 24 hr) were found to be inconsistent, and low in the case of PLGA, even taking the different loading efficiencies into account. Therefore, PCL (Mn 42,500) was selected as the favoured candidate scaffold material. The loading content and release profiles from methylene blue loaded collagen scaffold coatings were also evaluated. The drug loading capacity was found to be suitable for use as a drug delivery system (65±5 μg/g of methylene blue per unit scaffold mass). The release of methylene blue was observed to be rapid (between 54±10% – 70±17% in the first 24 hr), which was thought to be desirable for the coating delivery system. Recombinant human bone morphogenetic protein-7 (rhBMP-7) was used as a representative growth factor of interest for bone regenerative medical applications. It was loaded in collagen scaffold coatings (CoatBMP 1.25) and encapsulated within PCL (Mn 42,500) scaffolds (ScaffBMP 1.25). Control coatings and scaffolds were designated CoatPBS and ScaffPBS respectively. Both delivery systems were found to release detectable quantities of rhBMP-7 (releasing 2.8±0.2 μg/g and 87±7 ng/g respectively in the first 24 hr), even after 14 days. The release rate of the growth factor from the scaffold coating was higher than that from the encapsulating scaffolds. However, the cumulative release profiles were found to deviate from the desired ideal release profiles, and burst release was observed from both delivery systems. Although differences were observed for the two delivery systems, this difference may not be of clinical significance. Nevertheless, scaffolds with less than ideal delivery properties may still be of potential clinical use. The bioactivity of the rhBMP-7 released from the test scaffolds was therefore assessed by quantifying the area of normalised ALP staining of hMSCs. The release of rhBMP-7 from the collagen coating of the PCL (Mn 42,500) scaffolds (CoatBMP 1.25ScaffPBS) was capable of statistically significantly increasing hMSC normalised ALP expression, although the actual differences were often relatively small. Therefore, at least a proportion of the growth factor released is likely to have been bioactive. The release from scaffolds encapsulating rhBMP-7 (CoatPBSScaffBMP 1.25) did not have this effect on the hMSCs, indicating that either the concentration released was too low, or the growth factor released was no longer bioactive. However, when the cells were seeded directly onto the scaffolds, the activity of ALP, normalised by a DNA assay, was statistically significantly increased for the CoatPBSScaffBMP 1.25 scaffolds, in hMSCs from all three test patient donors (by 35±10% on the control). ALP activity was also significantly increased in hMSCs from two of the three patients seeded onto CoatBMP 1.25ScaffBMP 1.25 scaffolds (by 39±10% on the control). ALP activity was only statistically significantly increased for one of the hMSC patients when seeded onto CoatBMP 1.25ScaffPBS scaffolds (by 35±14% on the control). The functional osteoinductive capacity of Type-I collagen coated PCL (Mn 42,500) scaffolds loaded with rhBMP-7 was assessed using C2C12 cells seeded onto the scaffolds, and quantified using qRT-PCR. The genes of interest were; Type-I collagen (Col1), osteopontin (OP), ALP, osteocalcin (OC) and runt related transcription factor 2 (Runx2). The CoatBMP 1.25ScaffPBS scaffolds had an early osteoinductive effect on the C2C12 cells, as ALP, OC and Runx2 were elevated during the first 2 days only, compared to the control (e.g. by 44±12%, 128±42%, 60±25% and 46±25% respectively at the 24 hr mark). The CoatPBSScaffBMP 1.25 scaffolds also had an osteoinductive effect on the cells, which was more sustained than that observed for the CoatBMP 1.25ScaffPBS group. While OP, ALP and Runx2 were up-regulated in the first 24 hr compared to the control (by 38±10%, 208±82% and 72±31% respectively), statistically significant up-regulation of the late marker OC was delayed until the 48 hr mark (by 73±49%). The effect was found to be sustained until day 7, when OC and Runx2 were both statistically significantly up-regulated compared to the control (by 151±91% and 93±27% respectively). The CoatBMP 1.25ScaffBMP 1.25 scaffolds were found to combine the early effect of the CoatBMP 1.25ScaffPBS scaffolds, with the more sustained effect of the CoatPBSScaffBMP 1.25 scaffolds. ALP, OC and Runx2 were all up-regulated at the 24 hr mark (by 312±56%, 329±39% and 96±25% respectively). This osteoinductive effect was sustained until day 7 when Col1, ALP and Runx2 were still up-regulated compared to the control (by 174±78%, 72±24% and 178±78% respectively). These data suggest that the scaffolds containing rhBMP-7 have a weak osteoinductive effect on the cells seeded onto them. The different delivery systems were found to affect the cells differently. The clinical significance of this was not assessed in these studies. 1,25-dihydroxyvitamin D3 (1,25(OH)2D3) was used as a model drug to assess the feasibility of releasing lipid-soluble active factors from the scaffolds. This was assessed by quantifying the area of normalised ALP staining of hMSCs. The release of 1,25(OH)2D3 from the loaded collagen scaffold coatings and the encapsulating scaffolds significantly increased ALP expression compared to the control scaffold groups (by 115±28% and 69±25% respectively). Furthermore, ALP expression was significantly increased when the two delivery systems were used together, when compared to either delivery system on its own. These data suggest that the delivery of lipid-soluble active factors is feasible from collagen coated PCL scaffolds, and that the coating and encapsulating delivery systems are mutually compatible.
97

Metabolism of chloramphenicol succinate in human bone marrow and othertissue

Ambekar, Chhaya Sudhir. January 2000 (has links)
published_or_final_version / Medicine / Doctoral / Doctor of Philosophy
98

Telomere length variation and lineage chimerism in bone marrow transplantation

李玉嫻, Li, Yuk-han. January 2002 (has links)
published_or_final_version / Pathology / Master / Master of Philosophy
99

The expression of tissue inhibitor of metalloproteinase during the early stages of bone graft healing

Twitty, Anne. January 2000 (has links)
published_or_final_version / Dentistry / Doctoral / Doctor of Philosophy
100

Fatigue behaviour of hydrostatically extruded HAPEX

McGregor, William John January 2001 (has links)
No description available.

Page generated in 0.0515 seconds