  • Source
  • Publication year
  • to
  • Language
  • 26
  • Tagged with
  • 26
  • 26
  • 23
  • 22
  • 12
  • 12
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Alterações das dimensões dos arcos dentários e das inclinações dos incisivos produzidas pelo Sistema Damon / Arch width and incisor torque changes produced by the Damon System

Bezerra, Valeria Matos 19 December 2012 (has links)
PROPOSIÇÃO: O objetivo deste trabalho foi descrever as alterações das dimensões dos arcos dentários e das inclinações dos incisivos produzidas pelo Sistema Damon, durante a fase de alinhamento e nivelamento. Outro objetivo foi verificar a correlação destas alterações com o padrão de crescimento dos indivíduos. MATERIAL E MÉTODOS: modelos de estudo, telerradiografias convencionais e telerradiografias reconstruídas a partir de tomografias computadorizadas cone-beam de 22 casos tratados com o bráquetes Damon 3MXTM foram avaliados durante a fase de alinhamento e nivelamento. Os modelos de estudo foram obtidos ao início do tratamento (T0), após a primeira troca de fio (T1) e na inserção do fio de aço 0,019 x 0,025 (T2). Foram verificados os comprimentos de arco e as dimensões transversais nas regiões de caninos, primeiros e segundos pré-molares e primeiros molares mensuradas a partir das pontas de cúspides e margens gengivais linguais dos dentes, a cada etapa. Nas telerradiografias foram verificadas as alterações das inclinações dos incisivos inferiores e superiores, bem como o padrão de crescimento dos indivíduos. RESULTADOS: os comprimentos dos arcos e todas as distâncias transversais apresentaram aumentos significantes, com exceção da distância intercervical dos caninos superiores; houve aumento significante das inclinações vestibulares dos incisivos superiores e inferiores; o padrão de crescimento dos pacientes apresentou correlação significante com os aumentos transversais na região de pré-molares inferiores. CONCLUSÕES: o alinhamento e nivelamento de casos tratados sem extrações com o uso do Sistema Damon resultou no aumento significante das dimensões dos arcos dentários e das inclinações dos incisivos para vestibular. / OBJECTIVE: This study aimed to evaluate the dental arch widths and incisor torque changes produced by the Damon System during leveling and alignment. Other objective was to verify the correlation between these changes and the growth pattern. MATHERIAL AND METHODS: study casts and lateral radiographs derived from cone-beam computed tomographies of 22 subjects treated with Damon 3MXTM brackets were evaluated. The study casts were obtained at the start of treatment (T0), the first archwire change (T1), and the placement of the final 0,019 x 0,025-in archwire (T2). Arch depth and widths (intercanine, interpremolar and intermolar) were assessed at each stage. The incisor torques changes and the growth pattern were measured on the cephalometric records at T0 and T2. RESULTS: There was significant increase of the arch depths and lateral expansion of the arches for all measures, except for the intercervical of maxillary canines. The maxillary and mandibular incisors were significantly tipped labially; the growth pattern showed significant correlation with the lateral increases in lower premolars region. CONCLUSIONS: nonextraction cases treated with Damon System show significant increases in arch dimensions and incisors proclination.
12

Efeito da adição de nanotubos de carbono a dois adesivos ortodônticos utilizados para colagem indireta de bráquetes: estudo in vitro / Effect of micro-additions of carbon nanotubes to two orthodontic adhesives used for indirect bracket bonding: an in vitro study

Marchi, Paulo Guilherme Bittencourt 08 March 2016 (has links)
Made available in DSpace on 2017-07-10T14:57:31Z (GMT). No. of bitstreams: 1 paulo_ guilherme.pdf: 1519251 bytes, checksum: 15d6c712ac248d997ddd8dbce7c01880 (MD5) Previous issue date: 2016-03-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The adhesion evolution in dentistry, currently, has suggested the nanoparticles addition to the composites in order to improve their mechanical properties. The aim of this study was to compare direct and indirect bracket bonding and to evaluate possible changes due to carbon nanotubes (CN) addition to two adhesives used in indirect bonding by examining the following variables: shear bond strength (SBS), bond failure location and microleakage in the enamel/composite interface. One hundred and eighty bovine incisors underwent 37% phosphoric acid etching and were randomly divided into 9 groups (n=20): (1) direct bonding with Transbond XT adhesive; (2) indirect bonding with Sondhi adhesive; (3), (4) and (5) indirect bonding with Sondhi to which CN at 0.5%, 0.25% and 0.05% concentrations were included; (6) indirect bonding with Concise adhesive; (7), (8) and (9) indirect bonding with Concise to which CN at 0.5%, 0.25% and 0.05% concentrations were included. Transbond XT resin was used in all groups. Maximum SBS was measured with a mechanical testing machine, the location of bond failure was evaluated using the Adhesive Remnant Index (ARI) and the microleakage was measured utilizing scores. One-way analysis of variance followed by the Tukey test (P<.05) was used to compare the SBS among groups, and the differences in ARI and microleakage scores were evaluated using the Kruskal-Wallis test (P<.05). The SBS in group 1 was statistically higher than groups 2 to 6 (P<.05). ARI analysis did not reveal statistically significant differences among the groups (P>.05). In CN groups, there was no statistical difference (P>.05) in SBS or ARI. About the microleakage in the enamel/composite interface, there was a statistically significant difference in group 1 compared to groups 2 and 6, and in group 4 compared to groups 3 and 5 (P<.05). The direct technique was superior to the indirect technique in SBS and microleakage. CN addition to Concise and Sondhi, at the concentrations used, did not significantly increase SBS, ARI or microleakage. / A evolução na área da adesão em Odontologia tem, atualmente, sugerido o acréscimo de nanopartículas ao material adesivo com o propósito de melhorar as suas propriedades mecânicas. Diversos tipos de partículas de carga podem ser adicionados, e entre eles, estão os nanotubos de carbono. A técnica de colagem indireta de bráquetes ortodônticos, na qual os acessórios são posicionados no modelo de gesso da arcada dentária do paciente e, através de uma moldeira, são transferidos aos dentes, parece ser bastante vantajosa, porém, a adesão ainda gera dúvidas com relação à resistência e ao índice de falhas. O objetivo deste trabalho foi comparar as técnicas direta e indireta de colagem de bráquetes, além de avaliar possíveis alterações causadas pela adição de nanotubos de carbono a dois tipos de sistemas adesivos na colagem indireta de bráquetes com relação às seguintes variáveis: resistência de união por microcisalhamento, quantidade de compósito remanescente sobre o esmalte dentário, através do Índice de Remanescente Adesivo (IRA), e microinfiltração ocorrida sob os bráquetes. Para tanto, foram utilizados 180 incisivos bovinos divididos aleatoriamente nos seguintes grupos: G1 (Transbond Controle): colagem direta com adesivo Transbond XT (3M Unitek - Monrovia - EUA); G2 (Sondhi Controle): colagem indireta com adesivo Sondhi Rapid Set (3M Unitek, Monrovia, USA); G3, G4, G5: colagem indireta utilizando o adesivo Sondhi Rapid Set (3M Unitek, Monrovia, USA), com sua porção base acrescida de nanotubos de carbono nas concentrações, respectivamente de 1%, 0,5% e 0,1%; G6: (Concise Controle): colagem indireta com adesivo Concise (3M Unitek - Monrovia - EUA); G7, G8 e G9: colagem indireta utilizando o adesivo Concise (3M Unitek - Monrovia - EUA), com sua porção base acrescida de nanotubos de carbono nas concentrações, respectivamente de 1%, 0,5% e 0,1%. Para a colagem, em todos os grupos foi utilizada a resina composta 10 Transbond (3M Unitek - Monrovia - EUA). Os dados obtidos foram submetidos à análise estatística específica para cada uma das variáveis. Com relação à resistência ao microcisalhamento, observou-se diferença estatisticamente significante do grupo 1 em relação aos grupos 2 e 6 (p<0,05). No que diz respeito ao IRA, não houve diferença estatisticamente significante entre os grupos (p>0,05). Já com relação à microinfiltração ocorrida sob os bráquetes, houve diferença estatisticamente significante do grupo 1 em relação aos grupos 2 e 6, e do grupo 4 em relação aos grupos 3 e 5 (p<0.05). Com base nos resultados obtidos, concluiu-se que a técnica direta mostrou-se superior em relação à técnica indireta nos quesitos de resistência ao microcisalhamento e microinfiltração. Além disto, a adição de nanotubos de carbono aos sistemas adesivos Concise (3M Unitek - Monrovia - EUA) e Sondhi Rapid Set (3M Unitek, Monrovia, USA), não se mostrou vantajosa, nas concentrações avaliadas, no que diz respeito ao aumento da resistência ao microcisalhamento dos bráquetes, na quantidade de compósito remanescente sobre o esmalte dentário e na prevenção da ocorrência de microinfiltração sob os mesmos.
13

Detecção de microrganismos em bráquetes metálicos in vivo, com ou sem utilização de agente antimicrobiano, pela técnica Checkerboard DNA-DNA Hybridization

Soato, Marcela Cristina Damião Andrucioli [UNESP] 23 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-23Bitstream added on 2014-06-13T18:09:52Z : No. of bitstreams: 1 soato_mcda_me_arafo.pdf: 555873 bytes, checksum: b22c5adac5213b0dde7055e54baa52f5 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A presente Dissertação foi composta de dois estudos. O objetivo do primeiro estudo foi avaliar in vivo, por meio da técnica Checkerboard DNA-DNA Hybridization, a contaminação de bráquetes metálicos por 40 espécies diferentes de microrganismos pertencentes aos complexos amarelo, verde, laranja e vermelho, grupo dos Actinomyces e bactérias cariogênicas. Participaram do estudo 18 pacientes (11 a 29 anos), em tratamento ortodôntico, nos quais foram colados 2 bráquetes metálicos novos, em pré-molares diferentes. Decorridos 30 dias, os bráquetes foram removidos e processados pela técnica Checkerboard DNA-DNA Hybridization. Os resultados foram analisados por meio do teste não-paramétrico de Kruskal-Wallis e pós-teste de Dunn (α=5%). De acordo com os resultados obtidos, a maioria dos microrganismos estava presente em 100% dos indivíduos. Dentre os microrganismos cariogênicos, S. mutans e S. sobrinus foram encontrados em maiores quantidades que L. acidophillus e L. casei (p<0,001). As bactérias periodontopatogênicas pertencentes ao complexo laranja foram evidenciadas em maiores quantidades do que as pertencentes ao complexo vermelho (p<0,0001). Dentre os demais microrganismos não associados com patologias específicas, a espécie observada em maior quantidade foi V. parvula (p<0,0001), pertencente ao complexo roxo. A quantidade dos microrganismos dos complexos amarelo, verde e do grupo dos Actinomyces foram semelhantes (p>0,05). O objetivo do segundo estudo foi avaliar, in vivo, por meio da técnica Checkerboard DNA-DNA Hybridization, a contaminação de bráquetes metálicos por 17 espécies de microrganismos periodontopatogênicos dos complexos vermelho e laranja e a eficácia do gluconato de clorexidina a 0,12% (Periogard®), sob a forma de bochechos. Participaram do estudo 39 pacientes (11 a 33 anos), em tratamento ortodôntico, nos quais foram colados 2 bráquetes... / The present Master’s degree thesis was composed of two studies. The purpose of the first study was to evaluate in vivo by the Checkerboard DNA-DNA Hybridization technique the contamination of metallic orthodontic brackets by 40 microbial species of the yellow, green, orange and red complexes, Actinomyces group and cariogenic bacteria. Eighteen patients aged 11 to 29 years under orthodontic treatment were enrolled in this study and all subjects had 2 new metallic brackets bonded to different premolars in a randomized manner. After 30 days, the brackets were removed and processed for analysis by Checkerboard DNA-DNA Hybridization. The data were analyzed statistically by the non-parametric Kruskal-Wallis and Dunn’s post tests (α=5%). According to the obtained results, most evaluated microorganisms were present in 100% of the individuals. Among the cariogenic microorganisms, S. mutans and S. sobrinus were found in larger numbers than L. acidophillus and L. casei. (p<0.001). The periodontopathogenic bacteria of the orange complex were detected in larger numbers than the red complex bacteria (p<0.0001). Among the other microorganisms not associated with specific pathologies, V. parvula, belonging to the purple complex, was the most frequently detected specie (p<0.0001). The number of yellow and green complex bacteria and Actinomyces group microorganisms was similar (p>0.05). The purpose of the second study was to evaluate in vivo by the Checkerboard DNA-DNA Hybridization technique the contamination of metallic orthodontic brackets by 17 periodontopathogenic microorganisms of the red and orange complexes, and the efficacy of 0.12% chlorhexidine gluconate (Periogard®) mouthwashes against these microbial strains. Thirty-nine patients aged 11 to 33 years under orthodontic treatment were enrolled in this study and all subjects had 2 new metallic brackets... (Complete abstract click electronic access below)
14

Resistência ao cisalhamento de bráquetes ortodônticos após envelhecimento artificial acelerado / Shear bond strength of orthodontic brackets after accelerated artificial aging

Brahim Drubi Filho 09 December 2011 (has links)
O propósito deste estudo foi comparar a resistência ao cisalhamento (RC) e o índice de remanescente adesivo (IRA) após Envelhecimento Artificial Acelerado (EAA) de bráquetes ortodônticos metálicos fixados com compósitos autopolimerizável (Concise Ortodôntico - CS, 3M Unitek) e fotoativado (Transbond Plus Color Change - TPCC, 3M Unitek) com diferentes tratamentos de superfície do esmalte. Foram selecionados 60 pré-molares humanos recém extraídos, que tiveram suas raízes embutidas em resina acrílica ativada quimicamente de forma que a face vestibular ficasse perpendicular ao plano horizontal. Estas foram limpas com pedra pomes e água por 10 segundos, lavadas e secas. Os dentes foram separados aleatoriamente em 5 grupos (n=12), segundo o tipo de tratamento de superfície do esmalte, e do compósito utilizado para fixação dos bráquetes: Grupo I - ácido fosfórico a 37% (Dental Gel, Dentsply) e CS; Grupo II - ácido fosfórico a 37% + Primer e CS; Grupo III - ácido fosfórico a 37% e TPCC; Grupo IV - ácido fosfórico a 37% + XT Primer (3M Unitek) e TPCC; e Grupo V Transbond Plus Self Etching Primer - SEP (3M Unitek) e TPCC. Após 24h da colagem dos bráquetes, metade das amostras de cada grupo (n=6) foi submetida ao EAA por 960 horas. Todas as amostras foram submetidas ao ensaio de resistência ao cisalhamento com cinzel em máquina universal de ensaios (DL 200, EMIC) na velocidade de 0,5 mm/min. Após a descolagem dos bráquetes, causada pelo teste de resistência ao cisalhamento, o IRA foi avaliado em lupa (10X) e quantificado a partir de escore (0-3). Os dados foram analisados estatisticamente (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que não houve diferença estatisticamente significante entre os Grupos em função do EAA (p>0,05). Quando comparados os sistemas adesivos utilizados, verificou-se que o Grupo II sem EAA, apresentou a maior média de RC, resultado estatisticamente significante (p<0,05) em relação aos grupos III e V, que apresentou a menor média de RC. Quanto ao IRA, todos os grupos sem EAA apresentaram maior frequência do índice 3. Com EAA, houve aumento de frequência dos índices 1 e 2. Concluiu-se que o EAA não influenciou a RC de bráquetes ao dente, mas diminuiu a área de remanescente adesivo sobre o dente. / The purpose of this study was to compare the shear bond strength (SBS) and the adhesive remnant index (ARI) after Accelerated Artificial Aging (AAA) of metal orthodontic brackets bonded with self-polymerizing (Concise Ortodôntico - CS, 3M Unitek) and light activated (Transbond Plus Color Change - TPCC, 3M Unitek) composites, to enamel with different surface treatments. Sixty recently-extracted human premolars were selected. Their roots were embedded in chemically activated acrylic resin so that the vestibular face was perpendicular to the horizontal plane. They were cleaned with pumice stone and water for 10 seconds, washed and dried. The teeth were randomly separated into 5 groups (n=12), according to the type of enamel surface treatment, and composite used for bracket bonding: Group I - 37% phosphoric acid (Dental Gel, Dentsply) and CS; Group II - 37% phosphoric acid + Primer and CS; Group III - 37% phosphoric acid and TPCC; Group IV - 37% phosphoric acid + XT Primer (3M Unitek) and TPCC; and Group V Transbond Plus Self Etching Primer - SEP (3M Unitek) and TPCC. Twenty-four hours after bracket bonding, half the samples from each group (n=6) were submitted to AAA for 960 hours. All the samples were submitted to shear bond strength testing with a chisel, in a Universal Test Machine (DL 200, EMIC) at a speed of 0.5 mm/min. After bracket debonding caused by the shear bond strength test, the ARI was evaluated under a loupe (10X) and quantified according to a score (0-3). Data were statistically analyzed (2-way ANOVA, Bonferroni, p<0.05) and it was verified that there was no statistically significant difference among Groups as a function of AAA (p>0.05). When comparing the adhesive systems used, it was verified that Group II without AAA showed the highest mean SBS, a statistically significant result (p<0.05) in comparison with Groups III and V, which showed the lowest mean SBS. As regards ARI, all the groups without AAA showed higher frequency of Index 3. With AAA, there was increased frequency of indexes 1 and 2. It was concluded that AAA did not influence SBS of brackets to the tooth, but diminished the area of adhesive remnant on the tooth.
15

Exposição dos bráquetes ao meio bucal durante o tratamento ortodôntico e seu impacto no atrito / Intra-oral aging of orthodontic brackets and its impact on friction

Sérgio Elias Neves Cury 09 April 2018 (has links)
O objetivo desse trabalho foi avaliar as alterações nas ranhuras dos bráquetes após uso clínico e o seu impacto na alteração da força de atrito. Para isso foi realizada uma revisão sistemática da literatura, e um estudo prospectivo comparando os níveis de atrito antes e depois do uso clínico dos bráquetes, assim como comparando dois diferentes materiais para jateamento profilático. A revisão sistemática avaliou 7 artigos que cumpriram os devidos critérios de inclusão, a partir de busca eletrônica realizada em diversas bases de dados, sem limitações quanto a data e o idioma. Foram avaliados quanto a qualidade metodológica, e ao risco de viés de acordo com uma versão modificada do checklist de Donws and Black. 6 dos 7 artigos apresentaram resultados com aumento significativo da força de atrito após o bráquete ser submetido ao uso clínico. O segundo estudo do presente trabalho se trata de um estudo prospectivo in-vivo, ao qual 16 pacientes, submetidos a tratamento ortodôntico com bráquetes metálicos convencionais, compuseram 3 grupos de acordo com o protocolo de controle profilático realizado nos bráquetes de 2ºs pré-molares (Grupo 1 - pacientes submetidos à profilaxia com jateamento à base de bicarbonato de sódio; Grupo 2 pacientes submetidos à profilaxia com jateamento à base de glicina; Grupo 3 pacientes não foram submetidos à profilaxia profissional) Os bráquetes foram posteriormente removidos da cavidade oral e submetidos a ensaios de força de atrito, além de análise qualitativo da rugosidade superficial por microscopia eletrônica de varredura. O grupo controle (GC) para comparação foi constituído por bráquetes novos não submetidos à exposição em cavidade bucal. O teste de ANOVA seguido pelo teste Tukey foram utilizados para avaliar as diferenças entre os 4 grupos (GC, G1, G2 e G3). Os grupos de bráquetes usados apresentaram aumento da força de atrito, porém apenas o grupo que não foi realizado jateamento profilático a cada consulta (G3), apresentou diferença estatisticamente significante em relação ao Grupo Controle. Não houve diferença estatisticamente significante também quando comparados os dois diferentes materiais utilizados para o jateamento profilático. / The aim of this study was to evaluate the changes in bracket slots after clinical use and their impact on friction force. It is composed by a systematic review of the literature and a prospective study comparing the friction levels before and after the clinical use, as well as comparing two different materials for prophylactic blasting. The systematic review evaluated 7 articles that satisfied the inclusion criteria, based on electronic searches conducted in several databases, without limitations regarding publication year or language. The methodological quality and risk of bias were assessed according to a modified version of the Donws and Black checklist. 6 of the 7 articles presented significant increase in the friction force on retrieved brackets, after clinical use. The second study of the present study is a prospective in-vivo study which 16 patients were submitted to orthodontic treatment, divided in 3 groups according to the protocol of prophylactic control performed in brackets (Group 1 - patients submitted prophylaxis with sodium bicarbonate blasting, Group 2 - patients submitted to prophylaxis with glycine-based blasting, Group 3 - patients were not submitted to professional prophylaxis) Brackets were later removed from the oral cavity and subjected to friction force tests, in addition to qualitative analysis of surface roughness by scanning electron microscopy. The control group (CG) for comparison consisted of as received brackets (brand new brackets). The ANOVA test followed by the Tukey test were used to evaluate the differences between the 4 groups (GC, G1, G2 and G3). The retrieved groups presented an increase on friction force, but only the group that did not perform prophylactic blasting every appointment (G3) presented a statistically significant difference in comparison to the Control Group. There was no statistically significant difference also when comparing the two different materials used for prophylactic blasting.
16

Avaliação espectrofotométrica das alterações cromáticas de bráquetes estéticos armazenados em soluções potencialmente corantes

Fabre, Aubrey Fernando [UNESP] 17 December 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-12-17Bitstream added on 2014-06-13T20:57:10Z : No. of bitstreams: 1 fabre_af_me_araca.pdf: 1176776 bytes, checksum: 82e65eb62f8fff32b44bf512beef8e61 (MD5) / Objetivos. O presente estudo avaliou o comportamento cromático de bráquetes estéticos de diferentes materiais armazenados em soluções potencialmente corantes (água destilada, refrigerante, café e enxaguatório contendo álcool). Métodos. As amostras foram divididas em quatro grupos de acordo com a marca comercial e armazenadas em quatro tipos de soluções (água destilada, refrigerante, café e enxaguatório contendo álcool) a 37°C durante 14 dias. As possíveis alterações de cor foram mensuradas por meio de um espectrofotômetro de reflectância em cinco intervalos de tempo após o armazenamento. As alterações de cor foram registradas de acordo com o sistema CIE L*a*b* e a análise estatística foi conduzida empregando-se ANOVA a 1%, aplicação dos testes de Tukey e decomposição das interações com nível de significância a 5%. Resultados. As alterações de cor foram dependentes da solução, tempo de armazenamento e marca dos bráquetes. As maiores alterações de cor foram observadas nos bráquetes Invu™, seguido pelo Silkon Plus™, Composite® e Transcend™, com diferenças estatisticamente significantes. Significância. As soluções potencialmente corantes podem interferir na aparência dos bráquetes estéticos. Portanto, quando estes acessórios são utilizados, os pacientes devem ser informados sobre a possibilidade das alterações de cor ao longo do tempo e da necessidade de redução do consumo de produtos com potencial corante. / Objectives. The aim of this study was evaluated the chromatic behavior of the esthetic brackets of different materials exposure at the immersion in potentially staining solutions (distilled water, soda, coffe and mouthrinse with alcohol). Methods. The sample were divided in four groups of agreement with the commercial brand and stored in four types of the solutions (distilled water, soda to the base of cola, cofee and mouthrinse containing alcohol) at 37°C for 14 days. Color changes were measured by a reflection spectrophotometer in five time intervals after storage. The color changes were recorded according to the CIE L*a*b* system and the statistical analysis were carried out using ANOVA to 1%, application of the tests of Tukey and the decomposition of interactions with a significance level of 5%. Results.The color changes were dependent on the solution, storage time and the brand of brackets. The largest color changes were observed in the Invu™, followed by Silkon Plus™, Composite® and Transcend™ brackets, with statistic significance. Significance. The potentially staining solutions can interfere in the desirable appearance of esthetic brackets. Thus, when these attachments are used, the patient should be informed about possible color changes in the long-therm, and should reduce the consumption of potentially staining produtos.
17

Propriedades físico-químicas de bráquetes e fios ortodônticos utilizados em diferentes tempos de tratamento

Ramos, Aretha Aliny dos Santos 18 February 2014 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-03-16T12:14:26Z No. of bitstreams: 1 arquivototal.pdf: 1679756 bytes, checksum: 5065ecafba4b6ac4c0113ddd5cc81002 (MD5) / Made available in DSpace on 2017-03-16T12:14:26Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1679756 bytes, checksum: 5065ecafba4b6ac4c0113ddd5cc81002 (MD5) Previous issue date: 2014-02-18 / OBJECTIVE: The focus of this study was to test the hypothesis that treatment time and oral pH had an influence on the physical chemical properties of orthodontic brackets and arch wires. METHODS: 120 metal brackets were evaluated. They were divided into 4 groups (n=30): Group C (Control) and Groups T12, T24 and T36 (brackets recovered after 12, 24, and 36 months of treatment, respectively), rectangular stainless steel arch wires that remained in the oral cavity for 12 to 24 months were also analyzed. Dimensional stability, surface morphology and composition of brackets, resistance to sliding of the bracket/wire set and surface roughness of wires were analyzed by optical microscopy by measurement, scanning electron microscopy and energy dispersive x-ray, universal test machine and atomic force microscopy assays, respectively. Oral pH was evaluated by means of pH indicator strips by the colorimetric method. One-way analysis of variance ANOVA, followed by Tukey multiple comparisons test were used for statistical analysis (p<0.05). RESULTS: There was gradual influence of time from the 12th to 36th month for biofilm and food debris accumulation on bracket surfaces, presence of deformations on winglets and points of corrosion. Occlusal and cervical heights of brackets increased significantly after clinical use for 36 months, compared with new bracket heights (p<0.05). Carbon and Oxygen were shown to be elements that increased expressively and in direct proportion to time, and there was a progressive increase in the coefficient of friction and roughness of wires as a function of time of clinical use after 36 months. Oral pH showed significant difference only between group T36 and its control (p<0.05). CONCLUSIONS: The hypothesis was partially accepted, brackets and orthodontic wires suffered significant physical-chemical changes due to clinical use. However, the treatment time and biofilm and debris accumulation in bracket slots were shown to have more influence on the degradation process and frictional force of these devices than oral pH. / OBJETIVO: Este estudo teve como foco atestar a hipótese de que o tempo de tratamento e o pH bucal possuem influência sobre as propriedades físico-químicas de fios e bráquetes ortodônticos. MÉTODOS: Cento e vinte bráquetes metálicos foram avaliados, divididos em 4 grupos (n=30 por grupo): grupo C (Controle, como recebido do fabricante) e os grupos T12, T24 e T36 (bráquetes recuperados após 12, 24, e 36 meses de tratamento, respectivamente), fios de aço inoxidável retangulares que permaneceram na cavidade oral por 12 a 24 meses também foram analisados. Estabilidade dimensional, morfologia da superfície e composição dos bráquetes, resistência ao deslizamento do conjunto bráquete/fio e rugosidade superficial dos fios foram analisados por microscopia óptica de medição, microscopia eletrônica de varredura e por energia dispersiva de Raios X, máquina universal de ensaios e microscopia de força atômica, respectivamente. O pH bucal foi avaliado nos diferentes tempos de tratamento a partir de tiras indicadoras de pH pelo método colorimétrico. RESULTADOS: O tempo influenciou gradativamente do 12° ao 36° mês para o acúmulo de biofilme e detritos alimentares sobre a superfície dos bráquetes, presença de deformações nas aletas, além do aparecimento de pontos de corrosão. Alturas oclusal e cervical dos bráquetes aumentaram significativamente após o uso clínico de 36 meses comparado as alturas dos bráquetes novos (p<0.05). Carbono e Oxigênio demonstraram ser elementos com aumentos expressivos e diretamente proporcional ao tempo, assim como, houve um aumento progressivo do coeficiente de atrito e rugosidade dos fios em função do tempo de uso clínico com maior aumento após 36 meses. O pH bucal demonstrou diferença significativa apenas entre o grupo T36 com seu controle (p<0.05). CONCLUSÕES: A hipótese foi parcialmente aceita, bráquetes e fios ortodônticos apresentaram alterações físico-químicas significativas devido ao uso clínico. No entanto, o tempo de tratamento e o acúmulo de biofilme/detritos nos slots dos bráquetes demonstraram ser mais influentes sobre o processo de degradação e força de atrito destes dispositivos do que o pH bucal.
18

Análise in vitro do esmalte dentário, após diferentes métodos de remoção de resina composta residual utilizada para a colagem de bráquetes ortodônticos, em microscopia eletrônica de varredura / Analysis of dental enamel in vitro after different methods of residual resin removal using for bonding orthodontic brackets in scanning electron microscopy

Oliveira, Mileide de 23 August 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-04T15:39:10Z No. of bitstreams: 1 mileidedeoliveira.pdf: 2044599 bytes, checksum: cf2ec66abb87f42a989dc30fefcd5872 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-07T15:34:33Z (GMT) No. of bitstreams: 1 mileidedeoliveira.pdf: 2044599 bytes, checksum: cf2ec66abb87f42a989dc30fefcd5872 (MD5) / Made available in DSpace on 2016-06-07T15:34:33Z (GMT). No. of bitstreams: 1 mileidedeoliveira.pdf: 2044599 bytes, checksum: cf2ec66abb87f42a989dc30fefcd5872 (MD5) Previous issue date: 2011-08-23 / O presente estudo teve como objetivo analisar, in vitro, a superfície do esmalte dentário após diferentes métodos de remoção de resina residual após a descolagem de bráquetes ortodônticos metálicos. Foram utilizados 25 pré-molares humanos, hígidos, extraídos por indicação ortodôntica, os quais tiveram suas porções radiculares incluídas em resina acrílica, em matriz rígida de PVC. Em todos os espécimes foram colados bráquetes ortodônticos metálicos (Edgewise – Morelli) com a resina ortodôntica quimicamente ativada Super Bond (Ortho Source), de acordo com as orientações do fabricante. Os espécimes ficaram imersos em saliva artificial por 24 horas e em seguida foram removidos os bráquetes. Os espécimes foram divididos aleatoriamente em cinco grupos, de acordo com o método de remoção da resina remanescente. No grupo 1 a resina foi removida com aparelho de ultrasson (Altsonic), no grupo 2 com broca multilaminada 30 lâminas (JET) , no grupo 3 com ponta de óxido de alumínio (pedra Arkansas branca tipo pêra), no grupo 4 com alicate removedor de resina e no grupo 5 com discos de lixa (TDV) em ordem decrescente de granulação. Após a remoção da resina residual os espécimes tiveram suas coroas seccionadas com disco de carborundum no sentido transversal e longitudinal, deixando apenas a superfície vestibular da coroa para ser analisada em microscopia eletrônica de varredura. Os resultados foram submetidos à análise estatística, pelos testes de Anova e Tukey, com índice de significância de 5%. A broca multilaminada 30 lâminas e a ponta de óxido de alumínio foram os métodos que menos danificaram a superfície do esmalte, apresentando resultados estatisticamente significantes em relação aos outros métodos e deixando a superfície do esmalte satisfatória após a remoção da resina residual. / This study aimed to evaluate, in vitro, the enamel surface after different methods of removing residual resin after debonding of orthodontic brackets of metal. We used 25 human premolar, extracted for orthodontic indication, which had their root portions embedded in acrylic resin in rigid PVC matrix. In all specimens were bonded metallic orthodontic brackets (Edgewise - Morelli) with chemically cured orthodontic resin Super Bond (Ortho Source), according to the manufacturer's guidelines. The specimens were immersed in artificial saliva for 24 hours and then the brackets were removed. The specimens were randomly divided into five groups according to the method of removing residual resin. In group 1 the resin was removed with ultrasoun equipment (Altsonic) in group 2 with tungsten carbide bur (JET) in group 3 with aluminum oxide blaster (white Arkansas stone pear type) in group 4 with plier remover resin and in group 5 with sanding discs (TDV) in descending order of grain. After removing the residual resin specimens had their crowns sectioned with a carborundum disk in transverse and longitudinal, leaving only the buccal surface of the crown to be analyzed in scanning electron microscopy. The results were statistically analyzed by ANOVA and Tukey tests with significance level of 5%. The tungsten carbide bur and aluminum oxide blaster methods were less damaged enamel surfaces, with statistically significant results compared to other methods, leaving the enamel surface satisfactory after residual resin removal.
19

Avaliação da resistência ao cisalhamento de quatro combinações de sistemas adesivos e resinas compostas para fixação de bráquetes ortodônticos

Toledo Júnior, Evane Gonçalves de 21 December 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-09-09T18:00:28Z No. of bitstreams: 1 evanegoncalvesdetoledojunior.pdf: 1164428 bytes, checksum: 27c476e8596eb60a8efd9e8c6bfbc052 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-09-13T13:49:48Z (GMT) No. of bitstreams: 1 evanegoncalvesdetoledojunior.pdf: 1164428 bytes, checksum: 27c476e8596eb60a8efd9e8c6bfbc052 (MD5) / Made available in DSpace on 2016-09-13T13:49:48Z (GMT). No. of bitstreams: 1 evanegoncalvesdetoledojunior.pdf: 1164428 bytes, checksum: 27c476e8596eb60a8efd9e8c6bfbc052 (MD5) Previous issue date: 2011-12-21 / Avaliou-se a resistência ao cisalhamento de quatro diferentes combinações de materiais para fixação de bráquetes ortodônticos ao esmalte dental. Utilizou-se 80 incisivos inferiores bovinos divididos em 08 grupos (n=10). Nos grupos G1 e G5 empregou-se um sistema adesivo de três passos + resina composta híbrida; no G2 e no G6 o sistema adesivo de três passos + resina composta híbrida com liberação de flúor; no G3 e no G7 um sistema adesivo autocondicionante + resina composta híbrida; e no G4 e no G8 um sistema adesivo autocondicionante + resina composta híbrida com liberação de flúor, sendo que os grupos G5, G6, G7 e G8 foram submetidos à termociclagem de 1000 ciclos com temperatura variando de 5ºC ±1ºC a 55ºC ±1ºC, com 30s de imersão a cada banho. Em todos os grupos empregou-se bráquetes ortodônticos metálicos Roth Kirium. A seguir realizou-se o teste de cisalhamento em uma máquina de ensaios mecânicos universal a uma velocidade de 1mm/min.. Após esta etapa, o local de fratura foi avaliado ao Microscópio Eletrônico de Varredura (MEV), e as fraturas classificadas em adesiva, coesiva ou mista. Todos os corpos de prova apresentaram fratura do tipo coesiva. Concluiu-se que a superfície do esmalte foi preservada após o teste de cisalhamento e que todas as combinações de materiais testadas apresentaram valores adequados de resistência ao cisalhamento para uso clínico. / This study evaluated the shear bond strength of four different combinations of materials for bonding orthodontic brackets to enamel. Eighty bovine mandibular incisors were used and divided into 08 groups (n = 10). The materials studied were distributed as follows: groups G1 and G5 - three steps primer + hybrid composite; groups G2 and G6 - three steps primer + hybrid composite with fluoride release ; groups G3 and G7- self etching primer + hybrid composite, groups G4 and G8 – self etching primer + hybrid composite with fluoride release. Groups G5, G6, G7 and G8 were thermal cycled for 1000 cycles at temperatures ranging from 5°C ± 1°C to 55ºC ± 1°C, and 30s dip each bath. All groups tested received a metal bracket. The shear test was performed in a universal mechanical testing machine at a speed of 1mm/min and the fracture was assessed by Scanning Electron Microscopy (SEM). Fractures were classified as adhesive, cohesive or mixed. All specimens showed a cohesive fracture type, which preserved the enamel surface after bracket debonding in the shear test. All tested materials presented the shear strength within the clinical limits. After debonding enamel integrity was preserved.
20

Estudo microscópico da prevenção da desmineralização do esmalte dentário durante tratamento ortodôntico utilizando selante de fóssulas e fissuras

Campos, Maria Inês da Cruz 16 June 2009 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-03-24T19:41:16Z No. of bitstreams: 1 mariainesdacruzcampos.pdf: 3772933 bytes, checksum: d920efddd81a4b47ed532cc9a500b5d3 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-27T17:56:19Z (GMT) No. of bitstreams: 1 mariainesdacruzcampos.pdf: 3772933 bytes, checksum: d920efddd81a4b47ed532cc9a500b5d3 (MD5) / Made available in DSpace on 2017-03-27T17:56:19Z (GMT). No. of bitstreams: 1 mariainesdacruzcampos.pdf: 3772933 bytes, checksum: d920efddd81a4b47ed532cc9a500b5d3 (MD5) Previous issue date: 2009-06-16 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A desmineralização do esmalte dentário durante o tratamento ortodôntico é, ainda, um problema significante na Ortodontia. A presença de um aparato metálico retentivo sobre uma superfície dentária plana permite um sítio ideal para retenção de bactérias e restos alimentares, dificultando a higienização. O presente trabalho teve como objetivo avaliar através da lupa estereoscópica e da microscopia eletrônica de varredura, o efeito de um adesivo ortodôntico e um selante de fóssulas e fissuras na prevenção da desmineralização do esmalte ao redor dos bráquetes ortodônticos após exposição dos dentes à solução desmineralizadora. Foram utilizados 90 incisivos bovinos separados em três grupos de 30 dentes cada: grupo adesivo (G1), grupo selante de fóssulas (G2) e grupo controle (G3). Após a colagem dos bráquetes, os dentes foram submetidos a uma solução desmineralizadora durante 14 dias com monitoramento do pH através de um peagômetro. A análise por lupa estereoscópica e microscopia eletrônica de varredura mostrou que em todos os 90 dentes foram observados a ocorrência de desmineralização ao redor do bráquete ortodôntico. Entretanto, as áreas de perda de esmalte foram diferentes nos três grupos (ANOVA, p < 0,001). O grupo G2 apresentou uma redução significativa na incidência de desmineralização do esmalte (71,9%), enquanto esta redução no grupo G1 foi de 38%, quando comparados com grupo G3 (Tukey, p < 0,001). À microscopia eletrônica de varredura pode-se verificar a presença de crateras, poros e perda da camada aprismática do esmalte nos três grupos. O uso de selantes de fóssulas e fissuras para proteção da superfície vestibular dos dentes reduziu significativamente a desmineralização do esmalte in vitro. / The demineralization of dental enamel during orthodontic treatment is still a significant problem in Orthodontics. The presence of a retentive metallic apparatus on a dental flat surface allows an ideal site for retention of bacteria and food debris, making the cleaning difficult. This study aimed to evaluate through the stereoscopic microscope and scanning electron microscopy, the effect of an orthodontic adhesive and pit and fissure sealant preventing demineralization of enamel around orthodontic brackets after exposure of the teeth to demineralized solution. Ninety bovine incisors were used in three separate groups of 30 teeth each: adhesive group (G1), sealant of fossulae group (G2) and control group (G3). After bonding of brackets, the teeth were demineralized in a solution during 14 days with pH monitoring by a pH Meter. The analysis by stereoscopic microscope and scanning electron microscopy showed that in all 90 teeth was observed the occurrence of demineralization around orthodontic brackets. However, the areas of loss of enamel were different in the three groups (ANOVA, p < 0,001). The G2 group showed a significant reduction in the incidence of demineralization of enamel (71,9%), while the reduction in G1 was 38% when compared with group G3 (Tukey, p < 0,001). Scanning electron microscopy verified the presence of craters, pores and loss of the enamel aprismatic layer in the three groups. The use of pit and fissure sealant for protecting the labial surface of the teeth resulted in a significantly reduction of enamel demineralization in vitro.

Page generated in 0.0894 seconds