• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do processo de descontaminação de brocas odontológicas e seu impacto no controle de infecção

ANDERS, Patrícia Staciarini 31 March 2006 (has links)
Made available in DSpace on 2014-07-29T15:30:41Z (GMT). No. of bitstreams: 1 PatriciaAnders.pdf: 267735 bytes, checksum: ff715ff919969dde5ad2d1bb88ee588b (MD5) Previous issue date: 2006-03-31 / Objective: to describe the process of decontamination of burs to assess the microbial contamination of burs after-processing that were available to the use to isolate and to identify the possible microorganisms Methods: This study was conducted in 110 private dental offices of the central area of Goiânia-Goiás during the period of March/2004 to August/2005 using a check-list measure of dry heat sterilizer temperature and microbial burs tests The burs were seeded in brain heart infusion broth incubated at 37ºC for 20 days and subcultured on specific agar to isolate microorganisms The isolates were identified by micro/macroscopic characteristics subcultured on specific agar biochemical/enzymatic test and automation technique (MicroScan ®) Results:A total of 110 burs were evaluated and 35 (31.8%) were contaminated Fungi were detected in 13 (30.2%) burs [Aspergillus sp (27.9%) and Micelia (2.3%)]; Gram-positive cocci (staphylococci) represented 13 (30.2%) isolates [2.3% Staphylococcus aureus and 27.9% (12) coagulase negative staphylococci] nine (20.9%) isolates were Gram-positive bacilli and eight (18,6%) fastidioso microorganisms Considering the obtained results some factors detected could be interfered in the burs sterilization ineficiency: enzymatic detergent inadequate use abrasive products use inadequate dry heat sterilization time and temperature multiple use burs kits and interruption the asseptical chain after sterilization Conclusion: The frequency of contaminated burs was high (31.8%) and it was detected failures in operational steps of burs processing and/or after sterilization / Objetivos: descrever o processo de descontaminação das brocas odontológicas; avaliar a esterilidade das brocas pós-processamento que estavam disponíveis ao uso; isolar e identificar os possíveis microrganismos contaminantes Métodos: Os dados foram coletados em 110 consultórios odontológicos particulares do Distrito Central de Goiânia (GO) no período de março/2004 a agosto/2005 por aplicação de um check-list aferição da temperatura quando da utilização de estufa e realização do teste de esterilidade da broca As brocas foram inoculadas em caldo infusão de cérebro e coração com técnica asséptica Os caldos de cultura foram incubados a 37ºC por até 20 dias e ao apresentarem turvação foram repicados em meios específicos para isolamento dos microrganismos Estes foram identificados de acordo com características micro/macroscópicas desenvolvimento em meios de cultura seletivos provas bioquímicas e técnicas automatizadas (MicroScan®) Resultados: De um total de 110 brocas analisadas 35 (31,8%) estavam contaminadas Os fungos filamentosos foram identificados em 13 (30,2%) brocas [Aspergillus sp (27,9%) e Micelia sp (2,3%)]; cocos Grampositivos (Staphylococcus sp) representaram 13 (30,2%) isolados [Staphylococcus aureus (2,3%) e estafilococos coagulase negativos ECN (27,9%)] nove (20,9%) foram bacilos Gram-positivos e oito (18,6%) microrganismos fastidiosos Considerando os resultados obtidos alguns fatores podem ter interferido na qualidade da esterilização das brocas: a não utilização ou inadequações no uso de detergentes enzimáticos; uso de produtos abrasivos; inadequação no tempo de exposição/temperatura das estufas; kits não individualizados para atendimento havendo manuseio excessivo dos artigos; rompimento da cadeia asséptica pós-esterilização Conclusões: A freqüência de brocas contaminadas foi elevada (31,8%) Nos consultórios onde detectou-se brocas contaminadas ocorreram falhas nas etapas operacionais do processamento e/ou pós-esterilização
2

Determinação da vida de brocas utilizadas em implantodontia e influência das condições de corte / Life Twist Drills Used in Implantodology and Influence of the Cutting Conditions

Carneiro, Marcelo Bertolete 25 September 2009 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The aim of this work is to determine the life of twist drills used for dental implantology when drilling bovine tibia bones and to study the influence of the cutting conditions. The inputs variables considered were the cutting tool material, the feed velocity and the spindle speed. The outputs variables monitored were the number of drilled holes, the workpiece temperature, the thrust force and the tool wear. The tests were carried out in a CNC machine center and the cutting parameters were varied following a 23 experimental design. Three types of uncoated tool materials were used, a martensitic stainless steel (M340/Böhler), an austenitic stainless steel (AISI 316L) and a ceramic (zircon stabilized with Y2O3). The tool lives were expressed by the number of drilled holes considering a limit of the workpiece temperature of 47ºC, used as the end of tool life criterion. The temperatures were monitored by using three thermocouples of the type T (cupper-constantan) inserted in the work material samples, positioned very close to the drill wall. The thrust force was measured with a Kistler rotating dynamometer. A data acquisition board and a computer were used for automation of the measurement system. A mixture of 20% of car radiator fluid and water was applied as coolant (irrigation) with a flow rate of 160 ml/min. The results showed that the martensitic stainless steel outperformed the austenitic stainless steel and the ceramic material. The lowest temperatures and a conformity state at the clinic standard for thrust force values were obtained with the highest cutting parameters (45 mm/min and 2500 rpm). It was observed that the higher feed velocity promoted a temperature drop, while the higher spindle speed decreased the thrust force. / O objetivo deste trabalho é determinar a vida de brocas para implantodontia através de furação em tíbia bovina e estudar a influência das condições de corte utilizadas. As variáveis de entrada do trabalho foram o material de ferramenta, a velocidade de avanço e a rotação. E as variáveis de saída monitoradas foram o número de furos realizados, a temperatura próxima à parede óssea, a força de avanço e o desgaste das ferramentas. Os testes foram executados em um Centro de Usinagem variando os parâmetros de corte seguindo um planejamento experimental 23. Três tipos de materiais de ferramenta não revestidos foram utilizados, um aço inoxidável martensítico (M340/Böhler), um aço inoxidável austenítico (AISI 316L) e um cerâmico (zircônia estabilizada com Y2O3). A vida da ferramenta foi expressa pelo número de furos realizados considerando como critério de fim de vida a temperatura na peça igual a 47ºC. As temperaturas foram monitoradas pelo uso de três termopares do tipo T (cobre-constantan) inseridos no corpo-de-prova e posicionados próximo à parede do furo. A força de avanço foi medida com um dinamômetro rotativo Kistler. Uma placa de aquisição de dados e um computador foram utilizados para a automação do sistema de medição. Uma mistura de 20% de líquido de arrefecimento automotivo foi utilizada como refrigerante (irrigação) a uma vazão de 160 ml/min. Os resultados mostraram que o aço inoxidável martensítico superou o aço inoxidável austenítico e o material cerâmico. Menores temperaturas e um estado de conformidade aos padrões clínicos para valores de força de avanço foram obtidos com os maiores parâmetros de corte (45 mm/min e 2500 rpm). Observou-se que velocidade de avanço alta promove principalmente a queda da temperatura, enquanto a rotação elevada à queda na força de avanço. / Mestre em Engenharia Mecânica

Page generated in 0.2307 seconds