• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Freeze-thaw performance of prestressed concrete railroad ties

Albahttiti, Mohammed T. January 1900 (has links)
Doctor of Philosophy / Civil Engineering / Kyle Riding / Air voids are purposefully entrained in concrete to provide freeze-thaw durability of prestressed concrete railroad ties. Durability assurance requires consistent provision of an air void system comprised of small, well-distributed bubbles in sufficient quantity for durability and a quality control method for testing tie freeze-thaw durability. Manufacturing processes at three concrete manufacturing plants were investigated in order to determine the effects of process variability on resulting concrete air void system variability. Variation in the concrete air void system and other rheological properties occurred as results of the manufacturing process and vibration. Freezing and thawing durability testing of prestressed concrete ties is currently performed by applying ASTM C666 on 3 x 4 x 11 to 16 in. specimens cut from the shoulders of concrete ties. However, excising these specimens from prestressed concrete could lead to stress changes in the sample and cracking, potentially causing false interpretations of results. Therefore, testing was undertaken to understand the effects of prestressing and sample extraction on freeze-thaw durability measured by ASTM C666. In order to assess the effects of sampling and testing procedures on freeze-thaw quality control testing results of prestressed concrete railroad ties, full ties, half ties, and 3 x 4 x 11 in. excised samples were tested. Freeze-thaw testing included determination of the optimal method to measure freeze-thaw deterioration in large sections, the effects of saw-cutting, and the presence of reinforcement. Results indicated that the Ultrasonic Pulse Velocity accurately represented deterioration in large sections. The presence of reinforcement in excised samples led to faster deterioration compared to cast ASTM C666 samples, while saw-cutting without reinforcement did not significantly affect freeze-thaw durability.

Page generated in 0.0855 seconds