• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Freeze-thaw performance of prestressed concrete railroad ties

Albahttiti, Mohammed T. January 1900 (has links)
Doctor of Philosophy / Civil Engineering / Kyle Riding / Air voids are purposefully entrained in concrete to provide freeze-thaw durability of prestressed concrete railroad ties. Durability assurance requires consistent provision of an air void system comprised of small, well-distributed bubbles in sufficient quantity for durability and a quality control method for testing tie freeze-thaw durability. Manufacturing processes at three concrete manufacturing plants were investigated in order to determine the effects of process variability on resulting concrete air void system variability. Variation in the concrete air void system and other rheological properties occurred as results of the manufacturing process and vibration. Freezing and thawing durability testing of prestressed concrete ties is currently performed by applying ASTM C666 on 3 x 4 x 11 to 16 in. specimens cut from the shoulders of concrete ties. However, excising these specimens from prestressed concrete could lead to stress changes in the sample and cracking, potentially causing false interpretations of results. Therefore, testing was undertaken to understand the effects of prestressing and sample extraction on freeze-thaw durability measured by ASTM C666. In order to assess the effects of sampling and testing procedures on freeze-thaw quality control testing results of prestressed concrete railroad ties, full ties, half ties, and 3 x 4 x 11 in. excised samples were tested. Freeze-thaw testing included determination of the optimal method to measure freeze-thaw deterioration in large sections, the effects of saw-cutting, and the presence of reinforcement. Results indicated that the Ultrasonic Pulse Velocity accurately represented deterioration in large sections. The presence of reinforcement in excised samples led to faster deterioration compared to cast ASTM C666 samples, while saw-cutting without reinforcement did not significantly affect freeze-thaw durability.
2

Concreto de alto desempenho aplicado a sistemas de processamento e armazenagem de alimentos em baixas temperaturas / High performance concrete applied to storage and processing system buildings at low temperatures

Lima, Sandra Maria de 20 October 2008 (has links)
O desenvolvimento de um concreto de alto desempenho aplicado a sistemas de processamento e armazenagem de alimentos em baixas temperaturas teve por objetivo atender às indústrias de alimentos no Brasil que se utilizam da tecnologia do frio em seu processo industrial. A hegemonia mundial do mercado de carnes é brasileira, sendo que nossas indústrias são responsáveis por 33% desse mercado. A ausência de estudos para aprimorar e tornar as plantas industriais mais duráveis e condizentes com a importância do setor foi determinante na delineação do tema desta tese. Desenvolveu-se um concreto de alto desempenho frente às possíveis situações em uma planta industrial: baixas temperaturas em ambientes secos e baixas temperaturas em ambientes sujeitos à umidade. A temperatura mínima a qual foram submetidos os concretos analisados foi de 35°C. O método de dosagem e as diretrizes calcadas no reforço da matriz da pasta de cimento e refinamento de poros mostraram-se como uma alternativa para vencer as agressividades causadas pelas baixas temperaturas ao concreto. Até então, estudos sugeriam um sistema de ar cujos vazios teriam diâmetros em torno de 250 µm espaçados com esta mesma distância entre eles e com conteúdo de 6±1% para a proteção de concretos expostos a baixas temperaturas. A produção de um concreto coeso, com teor de ar de 3,5%, poros com diâmetro médio de 0,02 µm e com área específica de 2,84m²/g, provaram ser duráveis quando expostos ao congelamento e a ciclos de gelo e degelo. O fator de durabilidade para esses concretos foi de 97%. Além da durabilidade, o projeto de dosagem contemplou o aspecto econômico, produzindo 1MPa com 7,8 kg de cimento por metro cúbico de concreto. Os resultados foram obtidos por meio de ensaios dinâmicos, microscopia eletrônica de varredura, porosimetria por intrusão de mercúrio, absorção de água por imersão, além dos ensaios mecânicos de resistência à compressão, à tração na flexão e módulo de elasticidade. / Brazil has rapidly emerged as one of the world\'s leading meat exporters, being responsible by 33% of this market. In face of that, a high performance concrete (HPC), that can be applied to storage and processing system buildings at low temperatures, has been developed with the aim of answering the needs of brazilian food manufacturers that use cooling technology during industrial process. The lack of studies to improve industrial plants and make them more durable was determinant to delineate this thesis subject. A high performance concrete was designed to resist to low temperatures at dry environments as well as at moist ones. Concrete was exposed to a target temperature of -35°C. The dosage method and the guidelines based on the strengthening of bulk cement and the porous refinement showed to be an alternative to overcome the aggressiveness caused by low temperatures to concrete. To this day, studies have suggested air voids systems to protect concrete from low temperature effects. According to them, the air voids should have about 250 µm of diameter, spaced from each other this same distance and with an air content of 6±1%. However, making a cohesive concrete, with 3,5% of air content and an average diameter porous of 0,02 µm with an specific surface of 2,84m²/g, resulted in a durable concrete, even when exposed to frost / thawing cycles. The durability factor of these concretes achieved 97%. Besides durability, the dosage design brought economical advantages, producing 1 MPa with 7,8 kg of cement per cubic meter of concrete. The results were obtained through dynamic tests, scanning electron microscopy, mercury intrusion porosimetry and water absorption by immersion. In addition, tests of compression, tension strength and elastic modulus were carried out.
3

Concreto de alto desempenho aplicado a sistemas de processamento e armazenagem de alimentos em baixas temperaturas / High performance concrete applied to storage and processing system buildings at low temperatures

Sandra Maria de Lima 20 October 2008 (has links)
O desenvolvimento de um concreto de alto desempenho aplicado a sistemas de processamento e armazenagem de alimentos em baixas temperaturas teve por objetivo atender às indústrias de alimentos no Brasil que se utilizam da tecnologia do frio em seu processo industrial. A hegemonia mundial do mercado de carnes é brasileira, sendo que nossas indústrias são responsáveis por 33% desse mercado. A ausência de estudos para aprimorar e tornar as plantas industriais mais duráveis e condizentes com a importância do setor foi determinante na delineação do tema desta tese. Desenvolveu-se um concreto de alto desempenho frente às possíveis situações em uma planta industrial: baixas temperaturas em ambientes secos e baixas temperaturas em ambientes sujeitos à umidade. A temperatura mínima a qual foram submetidos os concretos analisados foi de 35°C. O método de dosagem e as diretrizes calcadas no reforço da matriz da pasta de cimento e refinamento de poros mostraram-se como uma alternativa para vencer as agressividades causadas pelas baixas temperaturas ao concreto. Até então, estudos sugeriam um sistema de ar cujos vazios teriam diâmetros em torno de 250 µm espaçados com esta mesma distância entre eles e com conteúdo de 6±1% para a proteção de concretos expostos a baixas temperaturas. A produção de um concreto coeso, com teor de ar de 3,5%, poros com diâmetro médio de 0,02 µm e com área específica de 2,84m²/g, provaram ser duráveis quando expostos ao congelamento e a ciclos de gelo e degelo. O fator de durabilidade para esses concretos foi de 97%. Além da durabilidade, o projeto de dosagem contemplou o aspecto econômico, produzindo 1MPa com 7,8 kg de cimento por metro cúbico de concreto. Os resultados foram obtidos por meio de ensaios dinâmicos, microscopia eletrônica de varredura, porosimetria por intrusão de mercúrio, absorção de água por imersão, além dos ensaios mecânicos de resistência à compressão, à tração na flexão e módulo de elasticidade. / Brazil has rapidly emerged as one of the world\'s leading meat exporters, being responsible by 33% of this market. In face of that, a high performance concrete (HPC), that can be applied to storage and processing system buildings at low temperatures, has been developed with the aim of answering the needs of brazilian food manufacturers that use cooling technology during industrial process. The lack of studies to improve industrial plants and make them more durable was determinant to delineate this thesis subject. A high performance concrete was designed to resist to low temperatures at dry environments as well as at moist ones. Concrete was exposed to a target temperature of -35°C. The dosage method and the guidelines based on the strengthening of bulk cement and the porous refinement showed to be an alternative to overcome the aggressiveness caused by low temperatures to concrete. To this day, studies have suggested air voids systems to protect concrete from low temperature effects. According to them, the air voids should have about 250 µm of diameter, spaced from each other this same distance and with an air content of 6±1%. However, making a cohesive concrete, with 3,5% of air content and an average diameter porous of 0,02 µm with an specific surface of 2,84m²/g, resulted in a durable concrete, even when exposed to frost / thawing cycles. The durability factor of these concretes achieved 97%. Besides durability, the dosage design brought economical advantages, producing 1 MPa with 7,8 kg of cement per cubic meter of concrete. The results were obtained through dynamic tests, scanning electron microscopy, mercury intrusion porosimetry and water absorption by immersion. In addition, tests of compression, tension strength and elastic modulus were carried out.

Page generated in 0.0711 seconds