• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 41
  • 21
  • 10
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Capacidade desativadora de espécies reativas de oxigênio e de nitrogênio por carotenoides e extrato de maná-cubiu = Scavenging capacity of carotenoids and extract from mana-cubiu against reactive oxygen and nitrogen species / Scavenging capacity of carotenoids and extract from mana-cubiu against reactive oxygen and nitrogen species

Rodrigues, Eliseu, 1983- 20 August 2018 (has links)
Orientador: Adriana Zerlotti Mercadante / Texto em português e Inglês / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-20T20:11:20Z (GMT). No. of bitstreams: 1 Rodrigues_Eliseu_D.pdf: 6784010 bytes, checksum: 5c87585adb4a85d2dd85217c8fee7430 (MD5) Previous issue date: 2012 / Resumo: Neste trabalho foi avaliada a capacidade antioxidante de carotenoides em sistema homogêneo e em lipossomas, de carotenoides microencapsulados e de extratos de maná-cubiu (Solanum sessiflorum) frente às espécies reativas de oxigênio (ROS) e espécies reativas de nitrogênio (RNS) de importância biológica. Devido à insolubilidade de carotenoides em solução tampão, utilizada como meio de reação no conhecido método oxygen radical absorbance capacity (ORAC), foi desenvolvido também um novo método para determinar a capacidade de carotenoides de desativarem o radical peroxila (ROO). Em geral, as microcápsulas de goma arábica e de maltodextrina (20 DE) contendo compostos antioxidantes (trolox, -tocoferol, ß-caroteno, apo-8¿-carotenal e apo-12¿-carotenal) foram capazes de desativar as ROS e RNS, sendo a eficiência de desativação influenciada pelo material de parede, pela espécie reativa (ROO, peróxido de hidrogênio (H2O2), radical hidroxila (HO), ácido hipocloroso (HOCl) e ânion peroxinitrito (ONOO-) e pela estrutura do composto antioxidante. Interessantemente, as microcápsulas vazias também foram capazes de desativar as ROS e RNS, sendo as de goma arábica mais eficazes que as de maltodextrina. A incorporação de apo-8¿-carotenal promoveu o maior aumento na capacidade das microcápsulas de desativarem ROS e RNS, variando de 50% a 132% e de 39% a 85% para goma arábica e maltodextrina, respectivamente. Este fato sugere que o apo-8¿-carotenal apresenta o melhor balanço entre a sua localização no interior das microcápsulas e a reatividade frente às espécies reativas. A localização também foi um fator importante na eficiência dos carotenoides desativarem ROS e RNS em lipossomas. Neste sistema, os carotenoides com grupos hidroxila foram geralmente mais potentes na desativação do ROO, HO e HOCl que carotenos, com destaque para a astaxantina, enquanto o ß-caroteno foi mais eficiente na desativação do ONOO-. Para o estudo dos carotenoides em sistema homogêneo foi desenvolvido e validado com sucesso um novo método para avaliação da capacidade de carotenoides de desativarem o ROO, o qual é baseado na perda de fluorescência da sonda ácido 4,4-difluoro-5-(4-fenil-1,3-butadienil)-4-bora-3a,4a-diazo-s-indaceno-3-undecanoico (C11-BODIPY581/591) devido à oxidação pelo ROO, que é gerado pela termodecomposição do azobisisobutironitrila (AIBN). A aplicação deste novo método permitiu o estudo da relação entre a estrutura química de diferentes carotenoides e a capacidade de desativar o ROO. Foi demonstrado que neste sistema os carotenoides são potentes desativadores desta espécie reativa, sendo a eficiência influenciada principalmente pela abertura do anel -ionona e pela extensão do cromóforo. O licopeno foi o mais potente desativador de ROO (8,67 0,74), porém não tão eficiente quanto os carotenoides do maná-cubiu (9,80 0,80). Os compostos bioativos de maná-cubiu foram determinados por cromatografia líquida de alta eficiência acoplada aos detectores de arranjo de diodos e espectrômetro de massas (HPLC-DAD-MS/MS). Esta fruta apresentou -caroteno (7,15 g/g) e luteína (2,41 g/g) como carotenoides majoritários. Por fim, o extrato fenólico de maná-cubiu, contendo o ácido 5-cafeoilquínico (1298 g/g) como composto fenólico principal, apresentou grande eficiência em desativar o H2O2 (IC50 = 305 17 g/mL) e o HOCl (IC50 = 13 0,8 g/mL). Os resultados do presente estudo mostram que os carotenoides foram capazes de desativar todas as ROS e RNS de relevância biológica avaliadas neste trabalho, sendo a eficiência de desativação influenciada pela concentração e estrutura química do carotenoide, pelo nível de organização do sistema (homogêneo ou multifásico) e pelo tipo de espécie reativa / Abstract: In the present study, the antioxidant capacity of carotenoids in homogeneous system and in liposomes, of microencapsulated carotenoids and of extracts from mana-cubiu (Solanum sessiflorum) were evaluated against reactive oxygen (ROS) and reactive nitrogen (RNS) species of biological relevance. Due to the insolubility of carotenoids in aqueous buffers, which is used as reaction medium in the well known oxygen radical absorbance capacity method (ORAC), a novel method was also developed to determine the peroxyl radicals (ROO) scavenging capacity of carotenoids. In general, the gum arabic and maltodextrin (20 DE) microcapsules containing antioxidant compounds (trolox, -tocopherol, ß-carotene, apo-8¿-carotenal and apo-12¿-carotenal) were capable to scavenge ROS and RNS. The scavenging efficiency of the microcapsules was influenced by the wall material, the reactive species (ROO, hydrogen peroxide (H2O2), hydroxyl radical (HO), hypochlorous acid (HOCl) and peroxynitrite anion (ONOO-) and the structure of the antioxidant compound. Interestingly, the empty microcapsules were also able to scavenge the ROS and RNS, being the gum arabic microcapsules more efficient than the maltodextrin ones. The incorporation of apo-8¿-carotenal resulted in the largest increase in the microcapsules scavenging capacity, varying from 50% to 132% and from 39% to 85% in the gum Arabic and maltodextrin microcapsules, respectively. These findings suggest that the apo-8¿-carotenal presented the best balance between its location in the microcapsules interior and the reactivity against the reactive species. The location was also an important factor influencing the efficiency of carotenoids to scavenge ROS and RNS in liposomes. In this system, the carotenoids with hydroxyl groups were usually more potent ROO, HO and HOCl scavengers than the carotenes, especially astaxanthin, whilst ß-carotene was the most efficient ONOO- scavenger. To study the carotenoids in homogeneous system, a new ROO scavenging assay, based on the loss of fluorescence of the probe 4,4-difluoro-5-(4-phenyl-1,3-butadienyl)-4-bora-3a,4a-diaza-s-indacene-3-undecanoic acid (C11-BODIPY581/591) due to its oxidation induced by ROO generated by the thermo decomposition of azobisisobutyronitrile (AIBN), was successfully developed and validated. This new method allowed the establishment of the relationship between the structure of different carotenoids and their ROO scavenging capacity. In this system, carotenoids showed to be potent scavengers of this reactive species, and their scavenging capacity was influenced mainly by the opening of the -ionone ring and by the chromophore extension. Lycopene was the most potent ROO scavenger (8.67 0.74); however, it was not so efficient as the carotenoids from mana-cubiu (9.80 0.80). The bioactive compounds of mana-cubiu were determined by high performance liquid chromatography coupled to diode array and mass spectrometry detectors (HPLC-DAD-MS/MS). The major carotenoids of this fruit were -carotene (7.15 g/g) and lutein (2.41 g/g). Finally, the main phenolic compound found in the phenolic extract from mana-cubiu was 5-caffeoylquinic acid (1298 g/g), which showed to be a good H2O2 (IC50 = 305 17 g/mL) and HOCl (IC50 = 13 0.8 g/mL) scavenger. The results of this thesis showed that the carotenoids are able to scavenge all the evaluated ROS and RNS of biological relevance and that their efficiency depends on the carotenoid structure and concentration, level of organization of the reaction medium (homogeneous or multiphase) and type of reactive species / Doutorado / Ciência de Alimentos / Doutor em Ciência de Alimentos
22

Uma metodologia de ensino do uso do hífen para alunos de ensino médio na modalidade educação de jovens e adultos

Motta, Katia Maria Ribeiro 15 February 2017 (has links)
Submitted by Josimara Dias Brumatti (bcgdigital@ndc.uff.br) on 2017-02-15T13:08:47Z No. of bitstreams: 1 Uma metodologia.pdf: 1412283 bytes, checksum: 9a4fe74670e47650eb81f9b516ebadb0 (MD5) / Made available in DSpace on 2017-02-15T13:08:47Z (GMT). No. of bitstreams: 1 Uma metodologia.pdf: 1412283 bytes, checksum: 9a4fe74670e47650eb81f9b516ebadb0 (MD5) / A presente tese apresenta uma proposta de ensino de língua portuguesa para alunos do Programa Nacional de Integração da Educação Básica com a Educação Profissional na Modalidade de Educação de Jovens e Adultos (PROEJA), baseada na metodologia Molar de abordagem de textos gramaticais do Prof. Dr. Maurício da Silva. A metodologia foi aplicada ao estudo das regras de emprego do hífen explicitadas no texto das Bases XV e XVI do Acordo Ortográfico da Língua Portuguesa de 1990, tendo em vista a grande importância do assunto em razão da entrada em vigor do Acordo em 2016 e a grande dificuldade de apreensão das referidas regras, bem como das convenções ortográficas em geral, manifestada pelos discentes da referida modalidade de ensino. A proposta criada e descrita nesta tese apoiou-se, também, na utilização da teoria de Gêneros Textuais como forma de mediar a transposição didática dos pressupostos teóricos. Assim sendo, apresenta-se aqui a criação de um material didático em que se corporificou essa transposição para textos dos gêneros bula, propaganda e cápsulas hifênicas. / This thesis presents a proposal on Portuguese language teaching to students of the National Elementary Education Integration Program with Vocational Education in the Youth and Adult Education Mode (PROEJA) based on the Molar methodology approach to grammatical texts by Dr. Mauricio da Silva. The methodology was applied to the study of the rules on the use of the hyphen explained in the Bases XV and XVI of the 1990 Portuguese Language Orthographic Agreement, due to the great importance of the subject, which will come into effect in 2016, and the great difficulties in apprehension of those rules, as well as spelling conventions in general, shown by students of the aforementioned mode of education. The proposal created and described in this thesis was supported by the Genre theory as a way to mediate the didactic transposition of the theoretical assumptions. Therefore, this paper presents the creation of pedagogical material that embodied this transposition to texts of CMI (Consumer Medicine Information) leaflets, advertising and hyphenic capsules.
23

Módulo fotônico para terapia fotodinâmica (PDT) em cápsulas endoscópicas / Photonic module for photodynamic therapy (PDT) in endoscopic capsules

Gounella, Rodrigo Henrique 28 June 2018 (has links)
A cápsula endoscópica é um instrumento revolucionário, que permite a realização de um exame livre de desconfortos para o paciente e possibilitou a técnica de endoscopia chegar a partes do sistema gastrointestinal que antes não era possível, como grande parte do intestino delgado. Este trabalho apresenta um módulo fotônico para realizar Terapia Fotodinâmica (PDT, Photodynamic Therapy) em cápsulas endoscópicas. A PDT é uma forma de tratamento para lesões que envolve a administração prévia de um medicamento fotossensível (PS, Photosensitizer) e posterior ativação com irradiação de luz em um comprimento de onda (λ) específico. Geralmente para a ativação do PS utiliza-se λ na região vermelha do espectro visível, pois a penetração nos tecidos é elevada. Células de adenocarcinoma gástrico humano (AGS, Adenocarcinoma Gastric of Stomach) foram preparadas com ácido 5-aminolevulínico (5-ALA) que é um Pró-fármaco precursor do agente fotossensível Protoporfirina IX (PpIX) com máximo de absorção nos 635 nm. Para realizar a irradiação com luz vermelha nas células, 16 LEDs do modelo LRQ396-P1Q2-1 da Osram Opto Semiconductors com dimensões muito reduzidas foram selecionados, caracterizados, montados em uma PCB (Printed Circuit Board) e alimentados por um Arduino Mega 2560. Este sistema de iluminação foi eficaz em seu propósito e causou morte celular nas células submetidas ao tratamento com o ALA em uma concentração de 2 milimol por litro e dose de luz em 5 Joules por centímetro quadrado que resulta em uma exposição de 49 minutos. Com o objetivo de se construir um módulo para controle de iluminação em cápsulas endoscópicas, foi desenvolvido em tecnologia CMOS 0.7 μm da ON Semiconductor um dispositivo capaz de controlar a intensidade dos LEDs utilizando PWM (Pulse Width Modulation). Unindo este componente com os LEDs selecionados é perfeitamente possível construir o módulo e inseri-lo CEs para realizar PDT em locais do trato gastrointestinal (GI) não acessíveis pela endoscopia convencional. / The endoscopic capsule is a revolutionary instrument that gives a free examination of discomforts for patient and allows the endoscopic technique to reach parts of the gastrointestinal system that were previously not possible, such as a large part of the small intestine. This work presents a photonic module to perform Photodynamic Therapy (PDT) in endoscopic capsules. PDT is a form of treatment for injuries involving prior administration of a photosensitive drug (PS, Photosensitizer) and subsequent activation with light irradiation at a specific wavelength (λ). Usually for PS activation, λ is used in the red region of the visible spectrum, because the tissue penetration is high. Human gastric adenocarcinoma cells (AGS) were prepared with 5-aminolevulinic Acid (5-ALA) which is a Pro-drug precursor of the photosensitive agent Protoporphyrin IX (PpIX) with maximum absorption at 635 nm. To perform red light irradiation on the cells, 16 LEDs, model LRQ396-P1Q2-1 of the Osram Opto Semiconductors with very small dimensions were selected, characterized, mounted on a PCB (Printed Circuit Board) and powered by an Arduino Mega 2560. This system was effective in its purpose and caused cell death in cells treated with ALA at a concentration of 2 mMol/L and dose of light at 5 J/cm² resulting in a 49 minutes exposure. With the objective of build a module for control of lighting in endoscopic capsules, a device able to controlling the intensity of the LEDs using PWM (Pulse Width Modulation) was developed in CMOS technology 0.7 μm of the ON Semiconductor. Combining this component with the selected LEDs, it is perfectly possible to construct the module and insert in CEs to perform PDT at sites of the gastrointestinal tract (GI) not accessible by conventional endoscopy.
24

Contaminação microbiana em medicamentos fitoterápicos sob a forma sólida / Microbial quality control of phytomedicines oral solid dosage forms

Fischer, Dominique Corinne Hermine 02 April 1992 (has links)
Foram analisados 84 lotes de especialidades fitoterápicas de uso oral, na forma de cápsula, comprimido e pó, contendo 17 drogas vegetais, produzidas por 20 fabricantes e comercializadas em farmácias, drogarias, lojas de produtos naturais e supermercados da cidade de são Paulo. O confronto da apresentação comercial das mesmas em relação à legislação nacional, indicou que a minoria (15/84) atendeu a tais exigências, além de ter demonstrado total falta de padronização de qualidade pelos produtores, inclusive com ausência de definição e conceituação, enquadrando-as indistintamente como medicamentos alopáticos, homeopáticos, produtos dietéticos ou alimentos. Efetuou-se a quantificação de bactérias aeróbias mesófilas (forma vegetativa e esporulada) e de fungos (bolores e leveduras), através da técnica de tubos múltiplos, bem como a pesquisa de Escherichia coli e Salmonella sp. pela metodologia oficial internacional. A contaminação fúngica, predominantemente de bolores, foi inferior em relação à bacteriana aeróbia mesófila, pois o máximo detectado para aquela foi de 4,6 X 105, enquanto que para esta 5,1 X 109/g. A incidência fúngica com carga maior ou igual a 102/g foi de 34,5%, contra 53,6% da carga bacteriana vegetativa com 104/g ou mais e 45,2% da bacteriana esporulada, com o mesmo nível. A determinação do Número Mais Provável de Escherichia coli indicou incidência de 6,0% com a carga maior igual a 1,5 X 102/g. Houve estreita relação entre a carga bacteriana vegetativa total e o número de esporos, assim como a presença de patogênicos específicos em produtos altamente contaminados. Amostras sob a forma de pó foram as mais afetadas, seguidas de cápsulas e comprimidos. Pelo confronto dos dados encontrados, com os diversos padrões microbianos aplicados para medicamentos não estéreis de uso oral, para insumos e produtos fitoterápicos, o índice de aprovação variou de 29,8 a 94,0%. Mesmo frente ao padrão da FIP, a rejeição especialidades fitoterápicas analisadas foi da ordem de 59,5%. Em vista da qualidade sanitária de muitos destes produtos ser imprópria para o consumo, e após análise crítica dos vários padrões microbianos, discutiu-se a necessidade de implantação de especificações nacionais, ainda que a caráter provisório, sugerindo-se limites de tolerância para medicamentos fitoterápicos de uso oral. / 84 samples of phytotherapic products of oral solid dosage forms (capsules, tablets and powders) containing 17 different crude drugs and produced by 20 laboratories, marketed in drugstores, herborist\'s and supermarkets at são Paulo-Brazil were analysed with regard to legal marketing requirements, only 15 samples were in accordance. A complete lack of quality standard was attributed to the manufacturers, including indefinition as to the classification of products among allopathic or homeopathic pharmaceuticals or foods or dietetics. The total aerobic bacterial (vegetative and sporulated forms) and fungal (moulds and yeasts) contents were determined by multiple tube technique; moreover tests were carried out for Escherichia coli and Salmonella sp. by official international methods. The fungal contamination was predominantly of moulds and lower than the aerobic bacterial one. The maximum counts were 4,6 X 105 and 5,1 X 109/g, respectively, for fungi and bacteria. The frequency of samples with or more than 102/g fungi/g was 34,5% that for vegetative and sporulated bacterial counts with or more than 104/g was respectively, 53,6 and 45,2%. The incidence of Escherichia coli was about 6,0% with the highest level at 1,5 X 102/g. There was a tight relation between the vegetative and sporulated bacterial counts as well as the presence of specific pathogenic microorganisms in highly contaminated samples. The highest contamination occured in powders followed by capsules and tablets. Comparing our experimental data with the corresponding microbial standards for oral non sterile pharmaceuticals, crude drugs and phytotherapic products, the index of approval varied between 29,8 and 94,0%. Even by FIP\'s standards 59,5% of the phytotherapic specialties analysed had to be rejected. As many of these products showed innadequate sanitary quality for consumption, coupled to a critical analysis of the different microbial standards, the discution was raised about the necessity of establishing national specifications, even if provisional. Suggestions are made as to the contamination limits of oral phytotherapic pharmaceuticals.
25

Abordagem metodológica envolvendo tensiometria e determinação da curva de retenção de água num solo de textura média / Methodological approach involving tensiometry and determination of the water retention curve in a medium texture soil

Franco, Helio Henrique Soares 02 March 2015 (has links)
A agricultura demanda grande quantidade de água para a produção de alimentos e fibras. Técnicas que determinem e monitorem a dinâmica da água no solo são importantes para promover o uso correto e consciente desse recurso natural. Diante do exposto, a tensiometria é uma ferramenta eficiente na determinação da dinâmica da água em solos agrícolas, podendo ser utilizada em conjunto com sensores de capacitância para a caracterização da curva de retenção de água no solo. Contudo, apesar de práticos, erros associados à instalação e às características das cápsulas podem comprometer a precisão dos tensiômetros. Esse trabalho teve como objetivo testar a influência do uso de lama de solo no momento da instalação, bem como o formato e condutância hidráulica de cápsulas de tensiômetros de punção sobre o potencial matricial da água no solo, tendo-se como referência tensiômetros com manômetro de mercúrio. Também, se objetivou determinar a curva de retenção de água no solo com base nos dados obtidos por tensiometria e de um sensor de capacitância. Os resultados mostram que o formato das cápsulas de cerâmica e a lama de solo influenciaram as determinações do potencial matricial, ao contrário da condutância hidráulica das cápsulas. A lama de solo é indicada na instalação de tensiômetros com manômetro de mercúrio e de punção. As curvas de retenção diferiram quanto aos sistemas de aquisição (manômetro de mercúrio ou tensímetro); no entanto, o modelo ajustado não foi sensível em distinguir diferenças entre os tratamentos quanto ao formato das cápsulas ou uso de lama de solo. De modo geral, ocorreu uma subestimativa dos ajustes das curvas de retenção para os tensiômetros de punção, o que pode levar a interpretações errôneas das curvas de retenção de água no solo quando determinadas por meio desses instrumentos. / The agriculture demand large amounts of water for food and fiber production. The techniques used to determine and monitor the water dynamics in the soil are important to promote the correct and conscious use of this natural resource. Given the above, the tensiometry is an efficient tool for the determination the water dynamics in soils, which can be used in conjunction with capacitance sensors to characterize the water retention curve in the soil. However, although practical, errors associated with the installation and the characteristics of the capsules may compromise the accuracy of tensiometers. This study aimed to test the influence of the use of soil slurry during the tensiometer installation, the format and hydraulic conductance of the capsules from puncture tensiometers on the matric potential of soil water, taking as reference tensiometers equipped with mercury manometers. In addition, aimed to determine the soil-water retention curve based on data obtained by tensiometry and a capacitance sensor. The results shows that the format of the ceramic capsules and the use of the slurry influenced the measurements of matric potential, as opposed to hydraulic conductance of the capsules. The soil slurry is recommended for tensiometers equiped with mercury manometer and puncture tensiometers. The retention curves differed among the acquisition systems (mercury manometer or tensimeter); however, the fitted model was not sensitive enough to distinguish differences between treatments for the format of the capsules or the use of soil slurry. In general, there was an underestimation of the retention curve for puncture tensiometers, which can lead to erroneous interpretations of the soil-water retention curve when determined by these instruments.
26

Desenvolvimento e avaliação \"in vitro\" de cápsulas de teofilina de liberação modificada em escala magistral / \"In vitro\" development and evaluation of magnetically-modified modified release theophylline capsules

Pinheiro, Vanessa Alves 27 September 2005 (has links)
Os médicos têm solicitado grande número de formulações diferenciadas, sob a forma de cápsulas de liberação lenta ou prolongada, aos farmacêuticos magistrais, com o objetivo de atender as necessidades específicas dos pacientes. Considerando que, praticamente, não há estudos sobre a liberação de fármacos a partir de formas magistrais de liberação prolongada, neste estudo, cápsulas de liberação modificada com 100 mg de teofilina foram preparadas com diferentes polímeros como os derivados celulósicos (Methocel® K100MPRCR, K15MPRCR e E4MCR) em diferentes concentrações, 15-35%. As cápsulas foram manipuladas, empregando o método volumétrico de enchimento de cápsulas. A lactose, de natureza hidrofílica, foi utilizada como diluente, quando necessário. Para o controle de qualidade das cápsulas, determinações de peso médio e teor de fármaco foram realizados nas 17 formulações desenvolvidas. A avaliação da dissolução das cápsulas foi feita de acordo com a Farmacopéia Americana 26 ed., para cápsulas de liberação prolongada (Teste 8), empregando aparato 1 (cesta), rotação de 100 rpm e temperatura mantida a 37ºC ± 0,5 em 900 mL de meio fluido intestinal sem enzimas (pH 7,5). Os perfis de dissolução foram comparados ao de duas especialidades farmacêuticas, sob a forma de cápsulas liberação prolongada. A formulação obtida com 35% da capacidade em volume de Methocel® E4MCR para cápsulas de tamanho 01 e lactose como diluente, evidenciou perfil de liberação de acordo com as especificações estabelecidas, sendo possível obter resultados reprodutíveis com 10 lotes da mesma formulação, através da padronização dos procedimentos adotados durante a manipulação dos mesmos. Por outro lado, as formulações comerciais de cápsulas de liberação prolongada contendo 100 mg de teofilina sob a forma de microgrânulos, quando submetidas ao mesmo ensaio de dissolução, apresentaram rápida liberação do fármaco, indicando que nestas formulações a liberação do fármaco não é fator limitante para a absorção. Para a avaliação da cinética de liberação do fármaco foram aplicados os modelos matemáticos de ordem zero, primeira ordem e Higuchi. Concluiu-se que as matrizes obtidas com os polímeros foram capazes de modular a liberação de teofilina envolvendo os mecanismos de difusão e erosão, prevalecendo o modelo de ordem um. / Pharmacists are called upon by physicians to compound a wide range of different products, including extended-release and slow-release capsules, when patients require specific individualized therapy. Considering that, practically, there aren\'t studies about compounded extended-release dosage forms, in this study, extended-release capsules of theophylline (100 mg) were prepared with different polymers as cellulose (Methocel® K100MPRCR, K15MPRCR e E4MCR) at different concentrations (15-35%). A hand filling relative volume process was used to prepare the matrix capsules. Lactose was used as hydrophilic diluent. For the quality control of capsules, average weight and assay were performed in 17 formulations. Dissolution rate of these capsules were evaluated according to United States Pharmacopeia 26 ed., dissolution method for theophylline extended-release capsules (Test 8). Determinations were performed with apparatus 1 (basket), agitation at 100 rpm and 900 mL of intestinal medium without enzimes (pH 7,5) were kept at 37ºC ± 0,5ºC. Dissolution profiles were compared to two other commercial extended-release capsules. The batch of capsules compounded with 35% volume capacity to capsules size number 1 of Methocel® E4MCR and with lactose as excipient showed dissolution profile according to the especifications and it was possible to reproduce the same results with more ten batches, through the standardized compounding procedure. On the other hand, commercial extended-release capsules containing theophylline pellets (100 mg) showed quick drug release, indicating that the drug release is not a limitant factor to the absorption. Mathematical models like zero¬-order, first-order and Higuchi were applied in kinetic studies of theophylline release from the capsules. The evaluation indicated that the polymers were efficient to control the release of theophylline in capsules and the involved mechanisms were diffusion and erosion and first-order was the model that better fitted for theophylline matrix capsules.
27

Avaliação comparativa do epitélio do esôfago de Barrett atráves da cápsula endoscópica do esôfago e endoscopia digestiva alta associada a cromoscopia com azul de metileno / Comparative evaluation of the epithelium of Barrett\'s esophagus through the esophageal capsule endoscopy and methylene blue chromoendoscopy

Domingos, Thiago Alonso 29 March 2011 (has links)
INTRODUÇÃO: O esôfago de Barrett (EB) é uma patologia que aumenta substancialmente o risco de adenocarcinoma esofágico. Os pacientes portadores de EB devem ser seguidos ao longo de toda a vida na tentativa da detecção de neoplasia em estágio precoce. A endoscopia digestiva alta (EDA) é, atualmente, o método de eleição. OBJETIVO: Avaliar a eficácia da cápsula endoscópica do esôfago (CEE) comparada à EDA com cromoscopia com azul de metileno para detecção de lesões suspeitas de neoplasia esofágica, avaliação da extensão e padrão do EB, e identificação da presença de hérnia de hiato; além de comparar a segurança e grau de desconforto dos dois métodos. MÉTODOS: Estudo de casos transversal, realizado em 22 pacientes sabidamente portadores de EB que foram submetidos à fundoplicatura à Nissen há mais de 5 anos. Os pacientes realizaram os exames de CEE e EDA com cromoscopia esofágica por médicos diferentes e desconhecedores dos achados do outro exame. Após a realização dos exames, foi aplicado um questionário onde foi anotado o grau de desconforto do paciente em cada exame e eventuais complicações. Foi avaliado o índice de concordância (kappa) entre os dois métodos para pesquisa de lesões suspeitas de neoplasia esofágica, características do EB e detecção de hérnia hiatal. RESULTADOS: Dezenove pacientes completaram o estudo. A CEE apresentou sensibilidade e valor preditivo negativo de 100% e acurácia de 79% para detecção de lesão suspeita de neoplasia esofágica e concordância razoável com EDA (kappa = 0,27). A acurácia da CEE para avaliação da extensão do EB foi de 89% e concordância moderada (kappa = 0,60) com EDA. A acurácia da CEE para avaliação de EB digitiforme, circunferencial e misto foram, respectivamente, 74%, 79% e 74% com concordância moderada nos casos de EB circunferencial e misto e não significante no EB digitiforme. Quanto à detecção de hérnia de hiato a CEE apresentou sensibilidade de 43% e acurácia de 74%, com concordância razoável (kappa = 0,38) com EDA. Não houve diferença estatística de desconforto entre os exames e não houve complicação em ambos os métodos endoscópicos. CONCLUSÕES: A CEE mostrou-se um bom método de detecção de lesões suspeitas de neoplasia esofágica. Quanto a avaliação da extensão e padrão do EB, a CEE apresentou resultados razoáveis, quando comparada à EDA com cromoscopia esofágica. A CEE apresentou resultados insatisfatórios quanto à detecção de hérnia hiatal. Não houve diferença significativa de desconforto entre CEE e EDA. Os dois métodos mostraram-se seguros / INTRODUCTION: Barrett\'s esophagus (BE) is a condition that substantially increases the risk of esophageal adenocarcinoma. Patients with BE should be followed throughout life in an attempt to detect cancer at an early stage. Upper gastrointestinal endoscopy (GIE) is currently the method of choice. OBJECTIVE: To evaluate the efficacy of esophageal capsule endoscopy (ECE) compared to methylene blue (MB) chromoendoscopy for detection of suspicious lesions of esophageal cancer, evaluation of extent and pattern of BE, and identifying the presence of hiatal hernia, in addition to compare the safety and patients discomfort of the two methods. METHODS: Transverse study, conducted on 22 Barretts patients submitted to Nissen fundoplication with more than five years follow-up. Patients underwent examinations of ECE and MB chromoendoscopy by different physicians blinds to each procedures. After the exams, patients discomfort and possible complications that occurred in each method were recorded. It was evaluated the concordance index between the two methods for detection of suspicious lesions of esophageal cancer, extent and pattern of BE and hiatal hernia detection. RESULTS: Nineteen patients completed the study. The ECE sensitivity, negative predictive value and accuracy were, respectively, 100%, 100% and 79% for detecting suspicious lesion of esophageal cancer and had reasonable agreement with MB chromoendoscopy (kappa = 0.27). The ECE accuracy for assessing the extent of BE was 89% and had moderate agreement (kappa = 0.60) with MB chromoendoscopy. The accuracy of the ECE for evaluation of finger-like, circumferential, and mixed BE were respectively 74%, 79% and 74%, and moderate agreement in cases of circumferencial and mixed BE and not significant agreement for finger-like BE. ECE sensitivity and accuracy for detecting hiatal hernia were, respectively, 43 % and 74%, and fair agreement (kappa = 0.38) with MB chromoendoscopy. There was no statistical difference between the discomfort of examinations and there was no complication in both endoscopic methods. CONCLUSIONS: The ECE has proved to be a good method for detecting suspicious lesions of esophageal cancer. As the evaluation of the extent and pattern of BE, the ECE had reasonable results, when compared to MB chromoendoscopy. The ECE had unsatisfactory results regarding the detection of hiatal hernia. There was no significant difference in discomfort between the ECE and GIE. Both methods proved to be safe
28

Desenvolvimento e avaliação \"in vitro\" de cápsulas de teofilina de liberação modificada em escala magistral / \"In vitro\" development and evaluation of magnetically-modified modified release theophylline capsules

Vanessa Alves Pinheiro 27 September 2005 (has links)
Os médicos têm solicitado grande número de formulações diferenciadas, sob a forma de cápsulas de liberação lenta ou prolongada, aos farmacêuticos magistrais, com o objetivo de atender as necessidades específicas dos pacientes. Considerando que, praticamente, não há estudos sobre a liberação de fármacos a partir de formas magistrais de liberação prolongada, neste estudo, cápsulas de liberação modificada com 100 mg de teofilina foram preparadas com diferentes polímeros como os derivados celulósicos (Methocel® K100MPRCR, K15MPRCR e E4MCR) em diferentes concentrações, 15-35%. As cápsulas foram manipuladas, empregando o método volumétrico de enchimento de cápsulas. A lactose, de natureza hidrofílica, foi utilizada como diluente, quando necessário. Para o controle de qualidade das cápsulas, determinações de peso médio e teor de fármaco foram realizados nas 17 formulações desenvolvidas. A avaliação da dissolução das cápsulas foi feita de acordo com a Farmacopéia Americana 26 ed., para cápsulas de liberação prolongada (Teste 8), empregando aparato 1 (cesta), rotação de 100 rpm e temperatura mantida a 37ºC ± 0,5 em 900 mL de meio fluido intestinal sem enzimas (pH 7,5). Os perfis de dissolução foram comparados ao de duas especialidades farmacêuticas, sob a forma de cápsulas liberação prolongada. A formulação obtida com 35% da capacidade em volume de Methocel® E4MCR para cápsulas de tamanho 01 e lactose como diluente, evidenciou perfil de liberação de acordo com as especificações estabelecidas, sendo possível obter resultados reprodutíveis com 10 lotes da mesma formulação, através da padronização dos procedimentos adotados durante a manipulação dos mesmos. Por outro lado, as formulações comerciais de cápsulas de liberação prolongada contendo 100 mg de teofilina sob a forma de microgrânulos, quando submetidas ao mesmo ensaio de dissolução, apresentaram rápida liberação do fármaco, indicando que nestas formulações a liberação do fármaco não é fator limitante para a absorção. Para a avaliação da cinética de liberação do fármaco foram aplicados os modelos matemáticos de ordem zero, primeira ordem e Higuchi. Concluiu-se que as matrizes obtidas com os polímeros foram capazes de modular a liberação de teofilina envolvendo os mecanismos de difusão e erosão, prevalecendo o modelo de ordem um. / Pharmacists are called upon by physicians to compound a wide range of different products, including extended-release and slow-release capsules, when patients require specific individualized therapy. Considering that, practically, there aren\'t studies about compounded extended-release dosage forms, in this study, extended-release capsules of theophylline (100 mg) were prepared with different polymers as cellulose (Methocel® K100MPRCR, K15MPRCR e E4MCR) at different concentrations (15-35%). A hand filling relative volume process was used to prepare the matrix capsules. Lactose was used as hydrophilic diluent. For the quality control of capsules, average weight and assay were performed in 17 formulations. Dissolution rate of these capsules were evaluated according to United States Pharmacopeia 26 ed., dissolution method for theophylline extended-release capsules (Test 8). Determinations were performed with apparatus 1 (basket), agitation at 100 rpm and 900 mL of intestinal medium without enzimes (pH 7,5) were kept at 37ºC ± 0,5ºC. Dissolution profiles were compared to two other commercial extended-release capsules. The batch of capsules compounded with 35% volume capacity to capsules size number 1 of Methocel® E4MCR and with lactose as excipient showed dissolution profile according to the especifications and it was possible to reproduce the same results with more ten batches, through the standardized compounding procedure. On the other hand, commercial extended-release capsules containing theophylline pellets (100 mg) showed quick drug release, indicating that the drug release is not a limitant factor to the absorption. Mathematical models like zero¬-order, first-order and Higuchi were applied in kinetic studies of theophylline release from the capsules. The evaluation indicated that the polymers were efficient to control the release of theophylline in capsules and the involved mechanisms were diffusion and erosion and first-order was the model that better fitted for theophylline matrix capsules.
29

Contaminação microbiana em medicamentos fitoterápicos sob a forma sólida / Microbial quality control of phytomedicines oral solid dosage forms

Dominique Corinne Hermine Fischer 02 April 1992 (has links)
Foram analisados 84 lotes de especialidades fitoterápicas de uso oral, na forma de cápsula, comprimido e pó, contendo 17 drogas vegetais, produzidas por 20 fabricantes e comercializadas em farmácias, drogarias, lojas de produtos naturais e supermercados da cidade de são Paulo. O confronto da apresentação comercial das mesmas em relação à legislação nacional, indicou que a minoria (15/84) atendeu a tais exigências, além de ter demonstrado total falta de padronização de qualidade pelos produtores, inclusive com ausência de definição e conceituação, enquadrando-as indistintamente como medicamentos alopáticos, homeopáticos, produtos dietéticos ou alimentos. Efetuou-se a quantificação de bactérias aeróbias mesófilas (forma vegetativa e esporulada) e de fungos (bolores e leveduras), através da técnica de tubos múltiplos, bem como a pesquisa de Escherichia coli e Salmonella sp. pela metodologia oficial internacional. A contaminação fúngica, predominantemente de bolores, foi inferior em relação à bacteriana aeróbia mesófila, pois o máximo detectado para aquela foi de 4,6 X 105, enquanto que para esta 5,1 X 109/g. A incidência fúngica com carga maior ou igual a 102/g foi de 34,5%, contra 53,6% da carga bacteriana vegetativa com 104/g ou mais e 45,2% da bacteriana esporulada, com o mesmo nível. A determinação do Número Mais Provável de Escherichia coli indicou incidência de 6,0% com a carga maior igual a 1,5 X 102/g. Houve estreita relação entre a carga bacteriana vegetativa total e o número de esporos, assim como a presença de patogênicos específicos em produtos altamente contaminados. Amostras sob a forma de pó foram as mais afetadas, seguidas de cápsulas e comprimidos. Pelo confronto dos dados encontrados, com os diversos padrões microbianos aplicados para medicamentos não estéreis de uso oral, para insumos e produtos fitoterápicos, o índice de aprovação variou de 29,8 a 94,0%. Mesmo frente ao padrão da FIP, a rejeição especialidades fitoterápicas analisadas foi da ordem de 59,5%. Em vista da qualidade sanitária de muitos destes produtos ser imprópria para o consumo, e após análise crítica dos vários padrões microbianos, discutiu-se a necessidade de implantação de especificações nacionais, ainda que a caráter provisório, sugerindo-se limites de tolerância para medicamentos fitoterápicos de uso oral. / 84 samples of phytotherapic products of oral solid dosage forms (capsules, tablets and powders) containing 17 different crude drugs and produced by 20 laboratories, marketed in drugstores, herborist\'s and supermarkets at são Paulo-Brazil were analysed with regard to legal marketing requirements, only 15 samples were in accordance. A complete lack of quality standard was attributed to the manufacturers, including indefinition as to the classification of products among allopathic or homeopathic pharmaceuticals or foods or dietetics. The total aerobic bacterial (vegetative and sporulated forms) and fungal (moulds and yeasts) contents were determined by multiple tube technique; moreover tests were carried out for Escherichia coli and Salmonella sp. by official international methods. The fungal contamination was predominantly of moulds and lower than the aerobic bacterial one. The maximum counts were 4,6 X 105 and 5,1 X 109/g, respectively, for fungi and bacteria. The frequency of samples with or more than 102/g fungi/g was 34,5% that for vegetative and sporulated bacterial counts with or more than 104/g was respectively, 53,6 and 45,2%. The incidence of Escherichia coli was about 6,0% with the highest level at 1,5 X 102/g. There was a tight relation between the vegetative and sporulated bacterial counts as well as the presence of specific pathogenic microorganisms in highly contaminated samples. The highest contamination occured in powders followed by capsules and tablets. Comparing our experimental data with the corresponding microbial standards for oral non sterile pharmaceuticals, crude drugs and phytotherapic products, the index of approval varied between 29,8 and 94,0%. Even by FIP\'s standards 59,5% of the phytotherapic specialties analysed had to be rejected. As many of these products showed innadequate sanitary quality for consumption, coupled to a critical analysis of the different microbial standards, the discution was raised about the necessity of establishing national specifications, even if provisional. Suggestions are made as to the contamination limits of oral phytotherapic pharmaceuticals.
30

Módulo fotônico para terapia fotodinâmica (PDT) em cápsulas endoscópicas / Photonic module for photodynamic therapy (PDT) in endoscopic capsules

Rodrigo Henrique Gounella 28 June 2018 (has links)
A cápsula endoscópica é um instrumento revolucionário, que permite a realização de um exame livre de desconfortos para o paciente e possibilitou a técnica de endoscopia chegar a partes do sistema gastrointestinal que antes não era possível, como grande parte do intestino delgado. Este trabalho apresenta um módulo fotônico para realizar Terapia Fotodinâmica (PDT, Photodynamic Therapy) em cápsulas endoscópicas. A PDT é uma forma de tratamento para lesões que envolve a administração prévia de um medicamento fotossensível (PS, Photosensitizer) e posterior ativação com irradiação de luz em um comprimento de onda (λ) específico. Geralmente para a ativação do PS utiliza-se λ na região vermelha do espectro visível, pois a penetração nos tecidos é elevada. Células de adenocarcinoma gástrico humano (AGS, Adenocarcinoma Gastric of Stomach) foram preparadas com ácido 5-aminolevulínico (5-ALA) que é um Pró-fármaco precursor do agente fotossensível Protoporfirina IX (PpIX) com máximo de absorção nos 635 nm. Para realizar a irradiação com luz vermelha nas células, 16 LEDs do modelo LRQ396-P1Q2-1 da Osram Opto Semiconductors com dimensões muito reduzidas foram selecionados, caracterizados, montados em uma PCB (Printed Circuit Board) e alimentados por um Arduino Mega 2560. Este sistema de iluminação foi eficaz em seu propósito e causou morte celular nas células submetidas ao tratamento com o ALA em uma concentração de 2 milimol por litro e dose de luz em 5 Joules por centímetro quadrado que resulta em uma exposição de 49 minutos. Com o objetivo de se construir um módulo para controle de iluminação em cápsulas endoscópicas, foi desenvolvido em tecnologia CMOS 0.7 μm da ON Semiconductor um dispositivo capaz de controlar a intensidade dos LEDs utilizando PWM (Pulse Width Modulation). Unindo este componente com os LEDs selecionados é perfeitamente possível construir o módulo e inseri-lo CEs para realizar PDT em locais do trato gastrointestinal (GI) não acessíveis pela endoscopia convencional. / The endoscopic capsule is a revolutionary instrument that gives a free examination of discomforts for patient and allows the endoscopic technique to reach parts of the gastrointestinal system that were previously not possible, such as a large part of the small intestine. This work presents a photonic module to perform Photodynamic Therapy (PDT) in endoscopic capsules. PDT is a form of treatment for injuries involving prior administration of a photosensitive drug (PS, Photosensitizer) and subsequent activation with light irradiation at a specific wavelength (λ). Usually for PS activation, λ is used in the red region of the visible spectrum, because the tissue penetration is high. Human gastric adenocarcinoma cells (AGS) were prepared with 5-aminolevulinic Acid (5-ALA) which is a Pro-drug precursor of the photosensitive agent Protoporphyrin IX (PpIX) with maximum absorption at 635 nm. To perform red light irradiation on the cells, 16 LEDs, model LRQ396-P1Q2-1 of the Osram Opto Semiconductors with very small dimensions were selected, characterized, mounted on a PCB (Printed Circuit Board) and powered by an Arduino Mega 2560. This system was effective in its purpose and caused cell death in cells treated with ALA at a concentration of 2 mMol/L and dose of light at 5 J/cm² resulting in a 49 minutes exposure. With the objective of build a module for control of lighting in endoscopic capsules, a device able to controlling the intensity of the LEDs using PWM (Pulse Width Modulation) was developed in CMOS technology 0.7 μm of the ON Semiconductor. Combining this component with the selected LEDs, it is perfectly possible to construct the module and insert in CEs to perform PDT at sites of the gastrointestinal tract (GI) not accessible by conventional endoscopy.

Page generated in 0.0467 seconds