• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 1
  • Tagged with
  • 12
  • 12
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Prédicteurs de la dégénérescence échocardiographique des greffons valvulaires suite à une procédure chirurgicale de Ross dans le traitement des maladies valvulaire aortiques

Simard, Louis 12 September 2019 (has links)
Les maladies valvulaires aortiques représentent la troisième affection cardiovasculaire la plus prévalente et la seconde indication la plus commune de chirurgie à coeur ouvert. Malgré des avancées médicales majeures, la seule option thérapeutique démontrée efficace pour réduire la mortalité demeure l’implantation d’une prothèse valvulaire. Deux grandes familles de prothèses existent, chacune d’elles présentant leurs propres avantages et inconvénients. Les valves mécaniques, en raison de leur structure en alliage métallique, comportent un haut risque thrombogénique et nécessitent l’instauration d’une anticoagulation permanente. Malheureusement, en plus d’être difficile à contrôler adéquatement, ce traitement pharmacologique augmente le risque de souffrir de saignements. Les prothèses mécaniques ont cependant démontré une excellente longévité, dépassant généralement les 25 ans. Les bioprothèses, quant à elles, ne nécessitent pas d’anticoagulation, mais sont connues pour dégénérer progressivement au fil des années et doivent typiquement être remplacées après 15 à 20 années. Conséquemment, les valves mécaniques demeurent préférables chez les patients présentant une longue espérance de vie, alors que les bioprothèses sont préférées chez les patients plus âgés (>65 ans). Néanmoins, aucune option parfaite n’existe et une controverse demeure quant au choix de la prothèse optimale pour les jeunes adultes (<60 ans). Dans le but d’éviter les désavantages significatifs des prothèses classiques, une troisième option chirurgicale a été proposée : la procédure de Ross. Elle consiste en un remplacement de la valve aortique dégénérée par la translocation de la valve pulmonaire native du patient en position aortique. Le chirurgien insère enfin une homogreffe en position pulmonaire pour compléter la procédure. Cette technique offre les meilleurs résultats hémodynamiques et permet d’éviter la médication anticoagulante. Cependant, elle augmente les risques de complications en nécessitant une double greffe et affecte un organe sain et fonctionnel, soit la valve pulmonaire. L’hypothèse principale à l’origine de ce projet de maîtrise était que la dégénérescence de l’autogreffe et de l’homogreffe est liée à des facteurs cliniques et les risques peuvent être prédits. Par conséquent, les objectifs principaux de cette étude étaient, dans un premier temps, d’évaluer l’intégrité des greffons valvulaires issus de la procédure de Ross lorsqu’effectuée chez une population de jeunes adultes atteints de maladies valvulaires aortiques sévères et, dans un second temps, d’identifier les déterminants et prédicteurs de mauvaise évolution postopératoire de l’autogreffe et de l’homogreffe pulmonaire. / Aortic valve diseases represent the third most prevalent cardiovascular disease and the second most common indication for open-heart surgery. Despite major breakthroughs in modern medicine and technologies, the only therapeutic option proved efficient in reducing mortality and morbidity remains the implantation of a valvular prosthesis. There are two major classes of prostheses, each presenting their own advantages and disadvantages. Mechanical valves, due to their alloy-based structure, hold a high thrombogenic risk profile and thus patients require a lifetime anticoagulating therapy. Unfortunately, beyond being a well-known clinical challenge to adequately control, this treatment significantly increases the risks of suffering from major bleeding events. However, mechanical valves have shown prolonged lifeexpectancy generally exceeding 25 years. As for bioprostheses, they do not require any anticoagulation but are widely known to degenerate progressively throughout the years and must typically be replaced after 15 to 20 years. Consequently, mechanical valves are currently preferred in patients with long estimated life-expectancy and bioprostheses are preferes in older patients (>65 years). Nonetheless, there are no perfect option and a strong controversy remains regarding the optimal prosthesis in young adults patients (<60 years). In order to overcome the significant drawbacks of the traditional prostheses, a third surgical option was proposed: the Ross procedure. It consists in replacing the degenerated aortic valve by translocating the native pulmonary valve in aortic position. The surgeon then uses a homograft in pulmonary position to complete the procedure. This technique offers the best hemodynamic profiles of all prostheses and allows a bypass of the anticoagulation therapy. On the downside, though, it increases complications risks and surgically affects a fully healthy and functional organ being the pulmonary valve. The main hypothesis at the root of this Master degree project was that the deterioration of autografts and homografts are linked to clinical factors and the risks can therefore be predicted. Therefore, the main objectives of this study were, first of all, to evaluate the integrity of Ross procedure grafts when performed in a young adult population suffering from severe aortic valve diseases and, secondly, to identify determinants and predictors of poor post-operative evolution of both the pulmonay autograft and homograft.
2

Étude des mécanismes métaboliques et athérosclérotiques impliqués dans la dégénérescence des bioprothèses valvulaires

Mahjoub, Haïfa 20 April 2018 (has links)
280 000 prothèses valvulaires sont implantées chaque année à travers le monde pour traiter des valvulopathies. Le remplacement valvulaire a amélioré le pronostic des patients atteints de valvulopathies. La tendance ces dix dernières années est en faveur de l’implantation des prothèses biologiques ou bioprothèses par rapport aux prothèses mécaniques et actuellement, près de 80% des valves implantées sont des bioprothèses (BPs). Les BPs sont moins thrombogènes que les prothèses mécaniques et ne nécessitent généralement pas de traitement anticoagulant mais leur principal inconvénient est leur durée de vie limitée. La dégénérescence structurelle de la bioprothèse (DSB) est la cause principale de sa dysfonction, elle consiste en une calcification des feuillets qui entraîne une sténose progressive de la BP et/ou une déchirure de feuillet responsable d’une régurgitation. On estime que 20 à 30% des BPs présenteraient un certain degré de dysfonction 10 ans après l’implantation. La DSB est donc la principale limitation à l’utilisation des BPs et aucun moyen efficace de traitement de la bioprothèse avant l’implantation n’a pu être établi pour stopper ou éviter la progression de la DSB. Cependant, des études récentes suggèrent que la DSB serait un processus complexe incluant plusieurs mécanismes : une inflammation liée à la présence de lipides qui ressemblerait au phénomène d’athérosclérose, un dépôt de calcium lié à un métabolisme phospho-calcique dysfonctionnel et une réponse immune. Ainsi de nouvelles perspectives de recherche pourraient aboutir au développement d’approches thérapeutiques que ce soit dans le choix de la prothèse ou le traitement à instituer au moment de la chirurgie afin de prévenir la DSB. Néanmoins, pour développer de nouvelles stratégies efficaces afin d’éviter la DSB, il est d’abord nécessaire de comprendre les mécanismes qui aboutissent à la DSB et d’identifier les facteurs liés à la prothèse ainsi que les facteurs cliniques et métaboliques liés au patient qui sont impliqués dans ces processus et en particulier ceux qui sont modifiables. L’objectif général du projet est d’élucider les mécanismes impliqués dans la pathogénèse de la dégénérescence structurelle des bioprothèses aortiques et d’identifier les facteurs cliniques et métaboliques qui déterminent de façon indépendante ce processus pathologique. / Worldwide it is estimated that 280 000 valve substitutes are implanted each year to replace diseased heart valves. Hence, valve replacement has improved the outcome of patients with valvular heart diseases. The trend over the last decade is towards the use of biological valves or bioprotheses instead of mechanical valves and at the present time, nearly 80% of the implanted valve substitutes are bioprostheses (BPVs). BPVs have a low thrombogenicity, which generally obviates the need for anticoagulation. However, the use of BPVs is still plagued by their limited durability. Structural valve deterioration (SVD) is the major cause of bioprosthetic valve failure expressed clinically by a progressive prosthetic stenosis due to leaflet calcification and/or by regurgitation due to leaflet tear. It is estimated that 20-30% of implanted BPVs will have some degree of dysfunction at 10 years. Thus, SVD is a major hurdle to the widespread utilization of BPVs. Unfortunately, there are currently no effective means by which progression of SVD may be reduced or stopped by the treatment of valve tissues before implantation. However, recent studies suggest that SVD is a complex process probably modulated by several mechanisms including an atherosclerotic-like lipid-mediated inflammation, a calcium deposit induced by a dysfunctional phospho- calcic metabolism and an immune response. Therefore, new directions of research could lead to the development of treatment approaches for the prevention of SVD such as the choice of a specific type of BPV or the initiation of a treatment at the time of valve replacement. Nonetheless, to develop new efficient treatments to avoid BPV failure, it is first required to understand the mechanisms leading to BPV SVD and to identify the factors related to the BPV itself and to the patient clinical and metabolic factors, especially the modifiable ones, that are involved in these processes. The general objective of the study is thus to elucidate the mechanisms implicated in the pathogenesis of structural valve deterioration of aortic bioprostheses and to identify the clinical and metabolic factors that independently determine this pathologic process.
3

Incidence, predictors and outcomes of myocardial injury following transcatheter aortic valve replacement

Ribeiro, Henrique B. 23 April 2018 (has links)
Tableau d’honneur de la Faculté des études supérieures et postdoctorales, 2015-2016 / L’implantation de valve aortique par cathéter (TAVI) a été développée comme une alternative thérapeutique pour les patients avec une sténose aortique sévère et ayant un risque opératoire élevé ou extrême en cas de chirurgie de remplacement valvulaire standard. Par rapport à la chirurgie à cœur ouvert classique, les procédures de TAVI sont moins invasives, parce qu'elles ne sont pas associées au clampage aortique et à la cardioplégie. Toutefois, la procédure implique un certain degré de dommage myocardique dû à la compression du tissu par le ballonnet et la prothèse transcathéter, ainsi que plusieurs courts épisodes d'hypotension extrême et d’ischémie myocardique globale, au cours de la stimulation ventriculaire rapide et du déploiement de la prothèse. De plus, l'approche transapicale, qui est réalisée lorsque l'approche transfémorale n’est pas possible, comprend la ponction de l'apex du ventricule gauche et l'introduction de larges cathéters ce qui augmente vraisemblablement encore les dommages myocardiques. En conséquence, presque tous les patients subissant un TAVI présentent un certain degré de dommage myocardique, défini par une augmentation des enzymes cardiaques, telles que la créatine kinase-MB (CK-MB), la troponine ou le peptide natriurétique de type B (BNP). Néanmoins, les données sur l'incidence exacte des dommages myocardiques, leur étendue, leurs prédicteurs, ainsi que les résultats échocardiographiques et cliniques associés, en fonction des différentes approches et prothèses sont limitées. Les objectifs généraux de mon projet de doctorat sont d'évaluer l'incidence, les facteurs prédictifs et les résultats des dommages myocardiques après TAVI pour le traitement des patients symptomatiques avec sténose aortique sévère ou bioprothèse dysfonctionnelle et à haut risque chirurgical. / Transcatheter aortic valve replacement (TAVR) has emerged as a less invasive therapeutic alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis at very high-risk or prohibitive perioperative risk. Compared to conventional open-heart surgery, TAVR procedures are less invasive, because they are not associated with aortic cross-clamping and cardioplegia. Even so, the procedure involves some degree of myocardial injury due to tissue compression, caused by the balloon and valve prosthesis, as well as several short episodes of extreme hypotension and global ischemia, during rapid ventricular pacing and valve deployment. Also, the transapical approach, which is an alternative to the transfemoral approach, involves the puncture of the ventricular apex and the introduction of large catheters through it. Accordingly, nearly all patients undergoing TAVR present some degree of myocardial injury, as defined by any increase in cardiac biomarkers, including creatine kinase-MB (CK-MB), troponin or B-type natriuretic peptides (BNP). Nonetheless, data on the exact incidence of myocardial injury, extent, predictors, as well as the associated echocardiographic and clinical outcomes, according to the different type of TAVR procedures and transcatheter valves, have been limited. The general objectives of my PhD project are to evaluate the incidence, predictors and outcomes of myocardial injury following TAVR for the treatment of high-risk patients with severe symptomatic AS or dysfunctional aortic bioprosthesis.
4

Développement de techniques de construction de valves aortiques par génie tissulaire

Tremblay, Catherine 23 April 2018 (has links)
Les maladies et malformations des valves cardiaques entraînent, chaque année, près de 300 000 opérations de remplacements, principalement réalisées sur les valves aortiques. Des valves de remplacement mécaniques ou biosynthétiques sont habituellement employées, mais leur utilisation implique plusieurs inconvénients, surtout chez les jeunes patients, puisque ces substituts inertes sont incapables de se remodeler en fonction des modifications apportées à l’environnement physiologique. Le génie tissulaire, c’est-à-dire la création de nouveaux tissus biologiques à partir de cellules vivantes, pourrait permettre d’enrayer les problèmes rencontrés avec les substituts traditionnels. Plusieurs techniques de construction de valves par génie tissulaire sont actuellement étudiées, notamment l’utilisation de matrices de polymère poreuses ou de valves décellularisées. Cette thèse présente le développement d’une toute nouvelle technique de construction de valves biologiques qui utilise la méthode d’auto-assemblage. Cette nouvelle technique permet de recréer la structure tridimensionnelle des valves en utilisant un matériau de base créé à partir de fibroblastes dermiques humains. Toutes les étapes ayant mené au développement de cette technique de construction jamais réalisée auparavant sont détaillées dans cette thèse. La méthode de fabrication du tissu de base est tout d’abord expliquée, puis le processus évolutif ayant mené à la construction de quatre prototypes est ensuite détaillé. Une méthode de construction utilisant différents gabarits a permis la mise en forme de valves possédant une structure similaire à celle des valves natives. Le comportement des nouveaux substituts a aussi été évalué à l’aide d’essais dynamiques en bioréacteur. Il a été démontré que les valves produites par auto-assemblage présentent un comportement normal sous une grande variété de conditions de débit et de pression et que les tissus ne sont pas endommagés par ces conditions de stimulation. Parallèlement, une étude de faisabilité sur la décellularisation de valves porcines réalisée avec la trypsine/EDTA a aussi été effectuée afin d’en évaluer le potentiel. Finalement, la caractérisation mécanique des tissus plans utilisés pour la fabrication des valves est aussi présentée. Cette étude permet de juger de la capacité des tissus à être utilisés pour remplacer les valves cardiaques et elle situe ce nouveau matériau par rapport à d’autres matériaux plans couramment employés. / Heart valves diseases lead annually to nearly 300 000 replacement surgeries, mostly performed on aortic valves. Mechanical or tissue valves are largely used to replace dysfunctional heart valves but they present serious drawbacks, mainly for young patients, since these non-living substitutes are unable to remodel according to physiological environment changes. Tissue engineering aims at the development of new biological organ substitutes created with living cells. Tissue engineered heart valves may be able to fully integrate their physiological environment and hence eliminate the problems encountered with mechanical and tissue valves. Porous polymer scaffolds or decellularized heart valves are current tissue engineering techniques that are being studied in order to develop new biological substitutes. This thesis, however, presents the development of an entirely new construction technique based on the self-assembly method that can recreate the aortic valve structure by using only human dermal fibroblasts cell sheets. The many steps achieved toward the development of this new construction technique are detailed in this thesis. The plane thick tissue fabrication method is first explained, along with the incremental evolutive process that led to the construction of four heart valve prototypes. The construction technique uses several templates to assist the three-dimensional shaping of the substitutes, which resemble the natural shape of the native aortic valve. Dynamic stimulations were also performed in a custom-made bioreactor and the valve exhibited a normal behavior under various flow and pressure waveforms. No damage was noted on the plane thick tissue after the mechanical stimulation. Besides, a feasibility study on the decellularization of porcine heart valves was conducted using Trypsin/EDTA in order to assess the potential of such a construction technique. Finally, the mechanical characterization of the plane tissue used for the construction of the valves is also presented. The results of this study confirm the ability of the tissues to act as a heart valve substitute. The new material is also compared to other commonly used materials in heart valve replacement or repair.
5

Fabrication de substituts de valves cardiaques par génie tissulaire avec la méthode par auto-assemblage sur gabarits tridimensionnels usinés

Lepage, Marc-Antoine 24 April 2018 (has links)
Alors que 1 % des patients pédiatriques souffrent de malformations cardiaques, les substituts valvulaires présentement disponibles sur le marché leur sont imparfaits : taille inadéquate, absence de croissance, etc. L’hypothèse est qu’il est possible de fabriquer par génie tissulaire, via la méthode par auto-assemblage, des substituts valvulaires adaptés aux besoins pédiatriques spécifiques. Ce projet de maîtrise, visant à améliorer la méthode de fabrication, s’inscrit à la suite de travaux précédents de notre groupe de recherche, qui avaient conduit à la mise au point de deux techniques de production. L’approche préconisée consiste à ensemencer directement des fibroblastes dermiques sur la surface de gabarits de polycarbonate, traités au plasma pour favoriser leur adhésion, suivi d’une maturation dans un milieu de culture sans sérum, puis d’une phase de contraction jusqu’aux dimensions prédéterminées, permettant aux rebords des feuillets une bonne coaptation. Pour ce faire, quatre expériences préliminaires ont d’abord été conduites afin de jeter les bases de la culture sur gabarits 3D usinés. Ces dernières ont permis d’obtenir des feuillets cellulaires manipulables sur des gabarits à géométrie simplifiée, d’améliorer leurs propriétés mécaniques selon le fini de la surface usinée et avec un milieu de culture sans sérum, de réduire leur pourcentage de contraction et d’optimiser le traitement plasma. Les essais de fabrication des substituts valvulaires ont par la suite permis de faire progresser la technique, mais n’ont pas produit les résultats escomptés. Ainsi, des optimisations restent à apporter afin que la méthode soit un succès. En effet, l’hypothèse principale quant à ces insuccès est liée à une surface d’échanges gazeux insuffisante entraînant potentiellement une hypoxie cellulaire et une acidification du milieu de culture secondairement au dioxyde de carbone. En regard des expériences préliminaires prometteuses, de futurs essais tenant compte des recommandations présentées dans ce mémoire pourraient toutefois mener à la fabrication de substituts valvulaires adaptées aux patients pédiatriques / While 1% of children are born with a cardiac defect, valve prostheses actually available on the market do not meet their needs: oversized, non-growing, etc. The hypothesis is that it is possible to fabricate a tissue-engineered heart valve prosthesis (TEHV) with the self-assembly method adapted to the paediatric specific needs. This master level project, with the objective of improving the fabrication method, follows the work of our research group, which led to two different valve prosthesis fabrication techniques. The chosen approach consists in seeding dermal fibroblasts directly on the surface of plasma treated polycarbonate templates to ensure cell adherence, followed by maturation in a serum-free cell culture media (SFM) and a contraction phase to predetermined dimensions, allowing for a good coaptation of the leaflets. To reach this goal, four preliminary experiments were first conducted to set the ground for cell culture on 3D machined templates. They led to manipulable cell sheets on templates with a simple geometry, to increased mechanical properties due to the machined surface characteristics and the SFM, to a reduced contraction percentage and to the optimization of the plasma treatment. Subsequently, valve prosthesis fabrication assays allowed the method to progress further but did not end with the expected results. Therefore, optimizations are still required to make the method succeed. Indeed, the main hypothesis for this failure is a too small gas exchange area potentially leading to cell hypoxia and culture medium acidification secondary to carbon dioxide. Following the promising preliminary experiments, future trials considering the recommendations made in this thesis could lead to the successful fabrication of TEHV adapted to the paediatric patients.
6

Caractérisation des cellules interstitielles des quatre différentes valves cardiaques chez le porc

Bouchard Martel, Joanie 13 April 2018 (has links)
La sténose aortique (SA) est la maladie valvulaire la plus importante des pays industrialisés et la troisième en importance au niveau des maladies cardiovasculaires. Cette maladie dégénérative entraîne un épaississement des feuillets valvulaires menant, dans certains cas, à la calcification de ceux-ci. Malheureusement, dans les débuts de la maladie, les effets néfastes de ces modifications sur la valve sont asymptomatiques et lorsque le diagnostic est posé, en raison des symptômes, il ne reste souvent qu'un traitement possible : le remplacement valvulaire. Plusieurs études sont aujourd'hui centrées sur la pathogénèse de la SA, mais très peu d'entre elles se sont intéressées à investiguer pourquoi la valve aortique (VA), parmi les quatre valves cardiaques, est celle qui se calcifié le plus rapidement. Cette étude cherche donc à identifier des différences entre la VA normale et les trois aux autres valves, pouvant expliquer sa propension à calcifier
7

Valves cardiaques par génie tissulaire : simplification des essais et concept tubulaire

Picard-Deland, Maxime 24 April 2018 (has links)
Les substituts valvulaires disponibles actuellement comportent encore plusieurs lacunes. La disponibilité restreinte des allogreffes, les risques de coagulation associés aux valves mécaniques et la durabilité limitée des bioprothèses en tissu animal sont toutes des problématiques que le génie tissulaire a le potentiel de surmonter. Avec la méthode d'auto-assemblage, le seul support des cellules consiste en leur propre matrice extracellulaire, permettant la fabrication d'un tissu entièrement libre de matériau exogène. Ce projet a été précédé par ceux des doctorantes Catherine Tremblay et Véronique Laterreur, ayant respectivement développé une méthode de fabrication de valves moulées par auto-assemblage et une nouvelle version de bioréacteur. Au cours de cette maîtrise, le nouveau bioréacteur a été adapté à une utilisation stérile avec des tissus vivants et la méthode de fabrication de valves moulées a été modifiée puis éprouvée avec la production de 4 prototypes. Ces derniers n'ont pas permis d'obtenir des performances satisfaisantes en bioréacteur, motivant la conception d'une nouvelle méthode. Plutôt que de tenter de répliquer la forme native des valves cardiaques, des études récentes ont suggéré une géométrie tubulaire. Cela permettrait une fabrication simplifiée, une implantation rapide, et un encombrement minimal en vue d'opérations percutanées. Cette approche minimaliste s'accorde bien avec la méthode d'auto-assemblage, qui a déjà été utilisée pour la production de vaisseaux de petits diamètres. Un total de 11 tubes ont été produits par l'enroulement de feuillets fibroblastiques auto-assemblés, puis ont été transférés sur des mandrins de diamètre inférieur, leur permettant de se contracter librement. La caractérisation de deux tubes contrôles a démontré que cette phase de précontraction était bénéfique pour les propriétés du tissu en plus de prévenir la contraction en bioréacteur. Les prototypes finaux pouvaient supporter un écoulement physiologique pulmonaire. Cette nouvelle méthode montre que le procédé d'auto-assemblage a le potentiel d'être utilisé pour fabriquer des valves cardiaques tubulaires. / High hopes are placed on tissue engineered heart valves to circumvent the restricted availability of allografts, the coagulation risks caused by mechanical valves and the limited durability of pericardial bioprostheses. With the self-assembly method, the only support for the cells is the extracellular matrix they themselves produce, allowing the tissue to be completely free from exogenous materials during its entire fabrication cycle. The project was preceded by those of the doctorate students Catherine Tremblay and Véronique Laterreur, who developed a new method to produce auto-assembled molded valves and a new version of the bioreactor used by our group, respectively. During this master, the new bioreactor has been adapted to a sterile use with living tissues and the molded valves method has been modified and tested with the production of 4 prototypes, which didn't provide satisfying results during their bioreactor trials. A new fabrication method was thus developed. Recently, the tubular shape has been suggested as a simple and effective geometry for tissue engineered heart valves, allowing easy fabrication, fast implantation, and minimal crimped footprint from a transcatheter delivery perspective. This minimalistic design is also well-suited for the self-assembly method, which has already proven its potential for small diameter vascular grafts. A total of 11 tubular constructs were produced by rolling self-assembled human fibroblastic sheets on solid mandrels. After maturation, the tissues were transferred onto smaller diameter mandrels to allow their free contraction. The characterization of two control tubes revealed that while preventing further contraction in the bioreactor, this precontraction phase was also beneficial for the tissue properties. The final prototypes could withstand a physiological pulmonary flow. This new method shows that the self-assembly process could be used to achieve functional tubular heart valves.
8

Traitement chirurgical des valvulopathies mitrales : impacts hemodynamique, fonctionnel et clinique

Magne, Julien 13 April 2018 (has links)
Les pathologies de la valve mitrale sont les valvulopathies les plus fréquentes dans le monde occidental. Elles touchent plus de 6% de la population de plus de 65 ans et ont un impact important sur la survie. L'insuffisance mitrale (IM) ischémique est une complication de la maladie coronarienne, fréquente à la suite d'un IDM. Son pronostic est sombre et le type de traitement chirurgical à appliquer demeure controversé. L'approche la plus commune pour répondre à 1TM ischémique est l'annuloplastie restrictive de la valve mitrale (ARVM) combinée au pontage aorto-coronarien. Cependant, la littérature rapporte des taux élevés de persistance d'IM à la suite de l'ARVM et la présence d'IM postopératoire est associée à un mauvais pronostic. Il est donc indispensable d'identifier les patients à haut risque de persistance d'IM après l'ARVM. Nous avons montré que la mesure des paramètres de la géométrie mitrale préopératoire permettait de prédire avec précision la persistance d'IM et le devenir des patients. L'ARVM consiste à implanter un anneau prothétique de petite taille afin de restaurer la coaptation des feuillets. Cependant, cette procédure peut limiter la mobilité des feuillets et causer une obstruction du flot mitral. Nos travaux ont montré que l'ARVM cause chez une proprotion importante de patients, une sténose mitrale fonctionnelle (SMF) associée à une augmentation de la pression artérielle pulmonaire et à une réduction de la capacité fonctionnelle. Nos travaux soulignent que l'ARVM est associée à un taux élevé de persistance/récurrence d'IM et/ou de SMF. Il est donc important d'identifier les patients à haut risque d'échec de l'ARVM et de développer de nouvelles techniques visant à mieux corriger PIM, sans induire de SMF. Lorsque la valve mitrale n'est pas réparable, le remplacement valvulaire mitral (RVM) est la seule solution. Une de nos étude a démontré que la présence de disproportion patientprothèse (DPP) après un RVM a un impact hémodynamique délétère et est associée à un taux de survie à long terme diminué. Ces travaux soulignent que lorsque le RVM est inévitable, il est important d'appliquer une stratégie afin d'éviter ou, tout du moins, de diminuer la sévérité de la DPP.
9

Contrôle adaptatif d'un bioréacteur cardiaque par algorithme génétique

Gosselin, Jérôme 24 April 2018 (has links)
Un bon fonctionnement du coeur humain est primordial pour maintenir une bonne qualité de vie. Cependant, lorsque le coeur est défaillant, certaines interventions chirurgicales s’avèrent nécessaires pour prolonger l’espérance de vie. Dans le cadre d’un projet multidisciplinaire reliant le génie mécanique avec le domaine biomédical, notre équipe travaille sur la fabrication de valves cardiaques conçues entièrement par génie tissulaire. Pour y parvenir, il est important d’obtenir des propriétés mécaniques optimales pour les tissus biologiques. Afin d’obtenir ces propriétés mécaniques, un outil important a été fabriqué lors d’une étude antérieure : le bioréacteur cardiaque. Le bioréacteur cardiaque permet de reproduire l’environnement physiologique du coeur, notamment les conditions de débit et de pression. Il est crucial de bien contrôler ces conditions, car celles-ci jouent un rôle important lors du conditionnement des substituts valvulaires. Toutefois, il est complexe de contrôler simultanément ces deux conditions de manière efficace. C’est pourquoi notre équipe s’est concentrée sur le développement d’une nouvelle stratégie de contrôle afin que le bioréacteur puisse reproduire le plus fidèlement possible l’environnement physiologique. Plusieurs techniques de contrôle ont été essayés jusqu’à maintenant. Par contre, leur précision était généralement limitée. Une nouvelle approche a donc été envisagée et est présentée dans ce mémoire. Cette nouvelle approche pour le contrôle du bioréacteur est basée sur un type d’algorithme bien connu mais encore très peu utilisé en contrôle : les algorithmes génétiques. Cette approche prometteuse nous a permis de produire des résultats dépassant tous ceux obtenus jusqu’à maintenant pour l’une des deux conditions, soit le débit physiologique. / A proper functioning of the human heart is essential for maintaining a good quality of life. However, when the heart fails, some surgical procedures are necessary to prolong life expectancy. As part of a multidisciplinary project linking mechanical engineering to biomedical science, our team is working on the manufacture of heart valves entirely designed by tissue engineering. To achieve this, obtaining optimum mechanical properties is an important aspect for the biological tissues. To obtain these mechanical properties, an important tool was designed in a previous study : the cardiac bioreactor. Cardiac bioreactors allow the reproduction of the physiological environment of the heart, including flow and pressure conditions. It is crucial to properly control these conditions, as they play an important role in valvular substitutes conditioning. However, it is complex to simultaneously control both conditions effectively. This is why our team has focused on developing a new control strategy so that the bioreactor can reproduce as faithfully as possible the physiological environment. Several control techniques have been experimented so far. However, accuracy was generally limited. So, a new approach has been considered and is presented here. This new approach is based on a well-known optimisation technique that is still quite unusual for control: genetic algorithms. This promising approach has allowed us to produce unprecedented results for one of the two conditions, the physiological flow.
10

Impact de l'obésité sévère en postopératoire de chirurgie coronarienne et valvulaire

Chassé, Michael 17 April 2018 (has links)
Au cours des dernières années, on a vu une augmentation radicale de la proportion de gens avec un indice de masse corporelle (IMC) dit extrême. Au Canada, de 1978 à 2004, la proportion de patients avec une obésité sévère de classe II (IMC > [ou égal à] 35 kg/m²) a plus de doublée (2,3% à 5,1%) et celle de classe III (IMC > [ou égal à] 40 kg/m²) triplée (0,9% à 2,7%). Ces patients à haut risque de maladies cardiovasculaire sont de plus en plus représentés en chirurgie cardiaque. En 2008, la "Society of Thoracic Surgeons" rapportait qu'environ 14% des patients opérés en chirurgie cardiaque avaient un IMC supérieur à 35 kg/m². Le présent projet traite du risque de complications associées l'obésité sévère en postopératoire de chirurgie coronarienne isolée et de remplacement valvulaire isolé. Il a pour but primaire de préciser si l'obésité sévère a un impact en ce qui a trait à la morbidité et mortalité postopératoire de ces chirurgies. Il a par également comme objectif de préciser la relation entre le tour de taille et le risque de complications dans ces deux populations chirurgicales. Nous avons montré que le risque de mortalité postopératoire en chirurgie coronarienne et valvulaire isolée n'est pas augmenté chez une population de patient avec une obésité sévère en comparaison avec des patients avec un IMC normal. Par contre, les patients en chirurgie coronarienne sont plus à risque de développer de la fibrillation auriculaire, de se faire réintuber, de présenter des embolies pulmonaires, de présenter des complications rénales, de développer des infections de plaies, une médiastinite et une septicémie. Les patients en chirurgie valvulaire isolée présentent quant à eux un risque accru d'insuffisance rénale nécessitant une thérapie de remplacement rénal, un taux plus élevé de médiastinite, de septicémie et d'infection de cathéter. Enfin, le tour de taille ne semble pas être un meilleur prédicteur de complications en chirurgie coronarienne ou valvulaire isolée. Par contre, en chirurgie coronarienne, le tour de taille pourrait sélectionner un groupe à plus faible risque de mortalité et de saignement postopératoire.

Page generated in 0.0494 seconds