• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 3
  • Tagged with
  • 11
  • 11
  • 11
  • 8
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Technologie výroby zadané součásti / On the production technology of a specific part

Kalina, Adam January 2015 (has links)
This document describes the design of new production technology specific part in an engineering company. The specific part is manufactured on a machining center by milling method. To create model was used SolidWorks software and to create CNC program was used SolidCAM program. There is production process created with new and old technologies. There is a comparison of both technologies in conclusion.
2

Estabilidade dimensional em prótese óculo-palpebral confeccionada por meio de modelo reverso obtido pelo sistema CAD/CAM / Dimensional stability in orbital prosthesis produced by means of reverse prototype generated by CAD/CAM system

Marafon, Priscila Galzo 09 May 2008 (has links)
A disponibilidade da tecnologia CAD/CAM na área biomédica suscitou o desenvolvimento deste trabalho, onde se avalia a estabilidade das dimensões faciais em prótese óculo-palpebral. Tomografias computadorizadas da face de 15 indivíduos voluntários, maiores de 25 anos de idade, não portadores de lesão congênita ou adquirida na região crânio-facial e de ambos os gêneros, foram reformatadas no sistema CAD, gerando imagens espelhadas de 30 modelos tridimensionais da região óculo-palpebral. Estes modelos foram processados no sistema CAM, empregando-se a sinterização seletiva a laser, dando origem a 30 protótipos de superfície. Paralelamente foram realizadas duas moldagens faciais em cada indivíduo, obtendo-se 15 pares de modelos em gesso da face, nos quais foram simuladas lesões óculo-palpebrais padronizadas nos lado direito e esquerdo. Os protótipos de superfície foram adaptados nos respectivos modelos em gesso, removidos e incluídos em mufla para obtenção da prótese óculo-palpebral em silicone. A definição de pontos antropométricos na área da prótese e na linha mediana da face possibilitou o estabelecimento de 31 medidas lineares empregadas para a avaliação da estabilidade das dimensões da prótese óculo-palpebral e de seu posicionamento na face. Fundamentando-se na análise comparativa das medidas observadas no lado da prótese e no lado contra-lateral íntegro que deu origem ao protótipo de superfície, conclui-se que a prótese óculo-palpebral não apresenta alteração de suas dimensões vertical, transversal e oblíqua. Não ocorre alteração na profundidade da prótese óculo-palpebral nos modelos da face, como também a prótese não sofre deslocamento espacial na face nos sentidos transversal e oblíquos. O conjunto das mensurações relativas ao lado da prótese óculo-palpebral não é estável em relação ao conjunto do lado contra-lateral que deu origem a esta prótese. A estabilidade dimensional da prótese óculo-palpebral e o seu posicionamento na face são compatíveis com a utilização em clínica do sistema CAD/CAM avaliado nesta pesquisa. / The CAD/CAM technology available in the biomedical area gave rise to the development of this study in order to evaluate the dimensional stability of orbital prosthesis. Face computerized tomography of 15 adults, men and women older than 25 years of age not bearing congenital or acquired craniofacial defect, were processed in CAD (computer-aided design) software to produce 30 reverse tridimensional models of the orbital region. These models were then processed in the CAM system (computer-aided manufacturing), by means of laser selective sintering, to generate surface prototypes of the orbital region. Two facial impressions of each subject provided 15 pairs of cast models and orbital defects were performed either in the right or left side of each stone model. The surface prototypes were adapted in the casts and then flasked to be processed in silicone. The demarcation of anthropometric landmarks within the prosthesis and in the face midline defined 31 linear measurements, used to evaluate the dimensional stability of the orbital prostheses and its location in the face. In conclusion, the comparative analyses of the measurements, observed in the prostheses and in the opposite sides that originated the surface prototypes, showed that silicone orbital prostheses presented similar vertical, transversal and oblique dimensions, as well as similar depth. There is no transverse or oblique displacement of the prostheses. Combined measurements in the prostheses\' side are not stable regarding the opposite side. The dimensional stability of orbital prostheses suggests that the CAD/CAM system evaluated herein may be used with clinical purposes.
3

Avaliação da posição do modelo auricular virtual gerado por imagem captada com escâner a laser e desenvolvimento de dispositivo posicionador 3D / Evaluation of the position of the virtual auricular model generated by image captured by laser scanning and development of 3D positioner device

Marafon, Priscila Galzo 13 March 2013 (has links)
Este trabalho fundamenta a aquisição de modelo digital auricular por meio do escâner de superfície e avalia o posicionamento tridimensional do modelo auricular digital, espelhado segundo medidas antropométricas faciais, com e sem referência anatômica do canal auditivo externo, bem como desenvolve um dispositivo posicionador tridimensional para prótese auricular. Os dados de dez indivíduos voluntários, adultos maiores de 25 anos de idade, não portadores de lesão congênita ou adquirida na região craniofacial e de ambos os gêneros foram submetidos ao Teste dos Postos Sinalizados de Wilcoxon (p0,05) e a medida angular C6 foi avaliada de forma porcentual. Os resultados demonstram que ocorre assimetria nas medidas lineares da posição dos modelos auriculares direitos e esquerdos espelhados nos respectivos lados contralaterais da face sem a referência do conduto auditivo externo, sendo duas vezes mais frequente no espelhamento do modelo auricular esquerdo no lado direito da face. Observa-se menor assimetria dos modelos auriculares direitos espelhados no lado esquerdo da face e simetria na posição dos modelos esquerdos espelhados no lado direito da face, com a referência do conduto auditivo externo. A medida angular C6 apresenta menor assimetria na posição dos modelos auriculares direitos do que nos esquerdos, espelhados nos respectivos lados contralaterais da face, com e sem a referência do conduto auditivo externo. Conclui-se que a utilização do conduto auditivo externo como referência anatômica proporciona melhor simetria linear e angular da posição dos modelos auriculares virtuais direitos e esquerdos, espelhados nos respectivos lados contralaterais da face. O dispositivo posicionador projetado possibilita o ajuste das assimetrias detectadas no espelhamento de modelos auriculares, promovendo a compensação das discrepâncias evidenciadas durante o planejamento virtual para posicionamento do modelo auricular. / This study substantiates the acquisition of auricular digital model, by means of surface scanner, and assesses the placement of three-dimensional auricular digital models, mirrored according to facial anthropometric measurements, with and without anatomical reference of the external auditory canal, as well as developing a prosthetic device for three-dimensional positioning of the mirrored auricular model. The digital data of ten volunteers, adults over 25 years old, not suffering from congenital or acquired lesions in the craniofacial region and of both genders underwent Wilcoxon Ranking Test (p0.05) and angular measurement C6 was assessed as percentage. The results show that occurs asymmetry regarding the linear measurements in the positioning of the right and left ear models when mirrored in their contra lateral side of the face without reference of the external auditory canal, being twice as common in mirroring the left auricular model on the right side of the face. It is observed less asymmetry in the right auricular models mirrored on the left side of the face and symmetry in the positioning of the left models mirrored on the right side of the face, with the reference of the external auditory canal. The angular measurement C6 shows less asymmetry in the positioning of the models right auricular model than in those of the left, mirrored in their contra lateral side of the face, with or without reference to the external auditory canal. The use of the external auditory canal as anatomical reference provides better linear and angular symmetry in positioning the virtual auricular right and left models, mirrored in their contra lateral side of the face The three-dimensional positioner device designed enables the adjustment of the asymmetries found in mirroring the digital auricular models, providing compensation for discrepancies evidenced during the virtual positioning of the auricular model.
4

Desadaptação marginal vertical de coroas confeccionadas com cerâmica no sistema computadorizado

Ademir Kiffer 08 August 2007 (has links)
O objetivo deste estudo foi avaliar in vitro a desadaptação cervical vertical de coroas confeccionadas com o sistema CEREC 3 utilizando dosi diferentes materiais para confecção de troquéis. Um modelo padrão em níquel-cromo foi confeccionado nas dimensões convencionais para o preparo de um canino superior. A partir da moldagem com silicone de adição do modelo mestre foram obtidos cinco troquéis com gesso Herostone (grupo 1) e conco com gesso CAM-base (grupo 2). Aos troquéis de gesso Herostone foi aplicado uma substância de contraste (CEREC powder). Os troquéis foram escaneados utilizando o sistema CEREC 3, por profissional calibrado, observando as orientações do fabricante. Dez coroas cerâmicas foram fresadas a partir das imagens obtidas no escaneamento. Com a utilização de um disco diamantado, foram marcados quatro pontos para medição da desadaptação marginal vertical no modelo padrão: vestibular, lingual, mesial e distal. As coroas forma fixadas no modelo padrão com adesivo à base de cianocrilato e posteriormente o conjunto modelo-padrão/coroa foram levados à observação no microscópio eletrônico de varredura sendo realizada quatro leituras em cada ponto, para obter a média, que foi considerado o valor da mensuração. Os resultados foram submetidos ao tratamento estatístico, aplicando-se os testes ANOVAOne Way e Tukey. Concluiu-se que as coroas confeccionadas com gesso CAM-base apresentaram menor desadaptação marginal vertical (69 um) em relação às produzidas com gesso Herestone mais aplicação CERC power (88 um). / The purpose of this study was to evaluate in vitro the inability to adapt marginal crown biult with the CERC 3 system use two unlike materials to making the die. A nickel-chromium pattern was made in conventional prportion an upper canine. A pattern model was impressing by adicion silicone and was made 5 dies with gypsum Herostone (group 1) and 5 dies with CAM-base gypsum (group 2). The dies were applied a contrast substance power CEREC. Those dies were scannied using a CEREC 3 system by qualified person, paying attention to the users guide. Ten ceramics crowns were passed a milling attending the images copied. Sing a diamond disk, were set four points to measure the marginal adapt into the pattern; bucal, lingual, mesial and distal. Those crowns were fixed into pattern with sticking made by cianocrilate and lately the pattern/crown were took get observation at the scanning electron microcopy, in prder to do the measures, were made four lectures in each point. The results were submitted to the statistics treatment, wich was applied the Anova one-way and Tuckey testis. Was achieved that the crowns made by gypsium CAM-base seemed less marginal desadaptation than respecting the does produced by gypsum Herostone plus the powder CEREC.
5

Avaliação da posição do modelo auricular virtual gerado por imagem captada com escâner a laser e desenvolvimento de dispositivo posicionador 3D / Evaluation of the position of the virtual auricular model generated by image captured by laser scanning and development of 3D positioner device

Priscila Galzo Marafon 13 March 2013 (has links)
Este trabalho fundamenta a aquisição de modelo digital auricular por meio do escâner de superfície e avalia o posicionamento tridimensional do modelo auricular digital, espelhado segundo medidas antropométricas faciais, com e sem referência anatômica do canal auditivo externo, bem como desenvolve um dispositivo posicionador tridimensional para prótese auricular. Os dados de dez indivíduos voluntários, adultos maiores de 25 anos de idade, não portadores de lesão congênita ou adquirida na região craniofacial e de ambos os gêneros foram submetidos ao Teste dos Postos Sinalizados de Wilcoxon (p0,05) e a medida angular C6 foi avaliada de forma porcentual. Os resultados demonstram que ocorre assimetria nas medidas lineares da posição dos modelos auriculares direitos e esquerdos espelhados nos respectivos lados contralaterais da face sem a referência do conduto auditivo externo, sendo duas vezes mais frequente no espelhamento do modelo auricular esquerdo no lado direito da face. Observa-se menor assimetria dos modelos auriculares direitos espelhados no lado esquerdo da face e simetria na posição dos modelos esquerdos espelhados no lado direito da face, com a referência do conduto auditivo externo. A medida angular C6 apresenta menor assimetria na posição dos modelos auriculares direitos do que nos esquerdos, espelhados nos respectivos lados contralaterais da face, com e sem a referência do conduto auditivo externo. Conclui-se que a utilização do conduto auditivo externo como referência anatômica proporciona melhor simetria linear e angular da posição dos modelos auriculares virtuais direitos e esquerdos, espelhados nos respectivos lados contralaterais da face. O dispositivo posicionador projetado possibilita o ajuste das assimetrias detectadas no espelhamento de modelos auriculares, promovendo a compensação das discrepâncias evidenciadas durante o planejamento virtual para posicionamento do modelo auricular. / This study substantiates the acquisition of auricular digital model, by means of surface scanner, and assesses the placement of three-dimensional auricular digital models, mirrored according to facial anthropometric measurements, with and without anatomical reference of the external auditory canal, as well as developing a prosthetic device for three-dimensional positioning of the mirrored auricular model. The digital data of ten volunteers, adults over 25 years old, not suffering from congenital or acquired lesions in the craniofacial region and of both genders underwent Wilcoxon Ranking Test (p0.05) and angular measurement C6 was assessed as percentage. The results show that occurs asymmetry regarding the linear measurements in the positioning of the right and left ear models when mirrored in their contra lateral side of the face without reference of the external auditory canal, being twice as common in mirroring the left auricular model on the right side of the face. It is observed less asymmetry in the right auricular models mirrored on the left side of the face and symmetry in the positioning of the left models mirrored on the right side of the face, with the reference of the external auditory canal. The angular measurement C6 shows less asymmetry in the positioning of the models right auricular model than in those of the left, mirrored in their contra lateral side of the face, with or without reference to the external auditory canal. The use of the external auditory canal as anatomical reference provides better linear and angular symmetry in positioning the virtual auricular right and left models, mirrored in their contra lateral side of the face The three-dimensional positioner device designed enables the adjustment of the asymmetries found in mirroring the digital auricular models, providing compensation for discrepancies evidenced during the virtual positioning of the auricular model.
6

Estabilidade dimensional em prótese óculo-palpebral confeccionada por meio de modelo reverso obtido pelo sistema CAD/CAM / Dimensional stability in orbital prosthesis produced by means of reverse prototype generated by CAD/CAM system

Priscila Galzo Marafon 09 May 2008 (has links)
A disponibilidade da tecnologia CAD/CAM na área biomédica suscitou o desenvolvimento deste trabalho, onde se avalia a estabilidade das dimensões faciais em prótese óculo-palpebral. Tomografias computadorizadas da face de 15 indivíduos voluntários, maiores de 25 anos de idade, não portadores de lesão congênita ou adquirida na região crânio-facial e de ambos os gêneros, foram reformatadas no sistema CAD, gerando imagens espelhadas de 30 modelos tridimensionais da região óculo-palpebral. Estes modelos foram processados no sistema CAM, empregando-se a sinterização seletiva a laser, dando origem a 30 protótipos de superfície. Paralelamente foram realizadas duas moldagens faciais em cada indivíduo, obtendo-se 15 pares de modelos em gesso da face, nos quais foram simuladas lesões óculo-palpebrais padronizadas nos lado direito e esquerdo. Os protótipos de superfície foram adaptados nos respectivos modelos em gesso, removidos e incluídos em mufla para obtenção da prótese óculo-palpebral em silicone. A definição de pontos antropométricos na área da prótese e na linha mediana da face possibilitou o estabelecimento de 31 medidas lineares empregadas para a avaliação da estabilidade das dimensões da prótese óculo-palpebral e de seu posicionamento na face. Fundamentando-se na análise comparativa das medidas observadas no lado da prótese e no lado contra-lateral íntegro que deu origem ao protótipo de superfície, conclui-se que a prótese óculo-palpebral não apresenta alteração de suas dimensões vertical, transversal e oblíqua. Não ocorre alteração na profundidade da prótese óculo-palpebral nos modelos da face, como também a prótese não sofre deslocamento espacial na face nos sentidos transversal e oblíquos. O conjunto das mensurações relativas ao lado da prótese óculo-palpebral não é estável em relação ao conjunto do lado contra-lateral que deu origem a esta prótese. A estabilidade dimensional da prótese óculo-palpebral e o seu posicionamento na face são compatíveis com a utilização em clínica do sistema CAD/CAM avaliado nesta pesquisa. / The CAD/CAM technology available in the biomedical area gave rise to the development of this study in order to evaluate the dimensional stability of orbital prosthesis. Face computerized tomography of 15 adults, men and women older than 25 years of age not bearing congenital or acquired craniofacial defect, were processed in CAD (computer-aided design) software to produce 30 reverse tridimensional models of the orbital region. These models were then processed in the CAM system (computer-aided manufacturing), by means of laser selective sintering, to generate surface prototypes of the orbital region. Two facial impressions of each subject provided 15 pairs of cast models and orbital defects were performed either in the right or left side of each stone model. The surface prototypes were adapted in the casts and then flasked to be processed in silicone. The demarcation of anthropometric landmarks within the prosthesis and in the face midline defined 31 linear measurements, used to evaluate the dimensional stability of the orbital prostheses and its location in the face. In conclusion, the comparative analyses of the measurements, observed in the prostheses and in the opposite sides that originated the surface prototypes, showed that silicone orbital prostheses presented similar vertical, transversal and oblique dimensions, as well as similar depth. There is no transverse or oblique displacement of the prostheses. Combined measurements in the prostheses\' side are not stable regarding the opposite side. The dimensional stability of orbital prostheses suggests that the CAD/CAM system evaluated herein may be used with clinical purposes.
7

Návrh a realizace CO2 Laseru s výkonem do 100W / Design and realization of CO2 laser with power up to 100W

Šrenk, Jakub January 2021 (has links)
This work is focused on the problematics of small CO2 lasers and their possible use for commercial production. The first part describes devices available on the market and evaluation of their parameters. The practical part specifies the parameters that arise from the potential use of technology. Based on these parameters, design of the machine and its complete mechanical design are elaborated. Furthermore, the experimental part deals with the design of structural components, control system, electrical systems and in general a complex technical-technological solution of the equipment, including economic evaluation of the design. Part of the work is also the construction of the machine itself, including activation, adjustment and debugging for the considered production. The constructed machine was subject to testing to ensure required quality of production.
8

Estudo comparativo de auxiliares de audição obtidos com sistema CAD/CAM e com método convencional de pré-moldagem

Marques, Janaína Benício 25 January 2017 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2017-07-26T14:12:57Z No. of bitstreams: 1 PDF - Janaína Benício Marques.pdf: 14648505 bytes, checksum: d012b9258828a4761e4dc0c746b9ce9a (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2017-08-29T15:31:07Z (GMT) No. of bitstreams: 1 PDF - Janaína Benício Marques.pdf: 14648505 bytes, checksum: d012b9258828a4761e4dc0c746b9ce9a (MD5) / Made available in DSpace on 2017-08-29T15:31:07Z (GMT). No. of bitstreams: 1 PDF - Janaína Benício Marques.pdf: 14648505 bytes, checksum: d012b9258828a4761e4dc0c746b9ce9a (MD5) Previous issue date: 2017-01-25 / OBJECTIVE: To compare earmolds obtained by the CAD / CAM system and the conventional pre-molding method. METHODS: Comfort sensations and anthropometric measures were analyzed in 30 ears of 15 volunteers randomly selected from a private clinic in a Brazilian Northeast Municipality, who underwent two procedures to obtain measurements, a CT scan composing the case group and preforming, constituting the control group. After the preparation of the silicone earmolds, the physical test of the devices was performed by the blind study method, in which the participants were not aware of the origin of each mold. RESULTS: The concepts Regular (53.3%), Good (20%) and Bad (20%), in the control group prevailed, based on the self-perception of the participants, while in the method proposed by the biomodel the concepts Good (73.3%) and Optimum (26.7%). As for the anthropometric linear measurements per ear in each of the evaluation forms: Conventional Preform, Conventional Silicone, Biomodel and Mold proposed significant differences (p <0.05) were found between the evaluation forms in the variables "Intertragic Incision - Top border of the Shell "," Length of the socket "" Depth of External Acoustic Meatus "," Thickness of EAM "and" Volume "in each ear. The coefficient of standard deviation being less than half of the corresponding mean values.CONCLUSION: In view of the above, it is possible to obtain atrial molds from tomographic images with favorable results. / OBJETIVO: Comparar auxiliares de audição obtidos pelo sistema CAD/CAM e pelo método convencional de pré-moldagem. METODOLOGIA: Foram analisadas as sensações de conforto e medidas antropométricas em 30 orelhas de 15 voluntários escolhidos aleatoriamente de uma clínica particular de um município do Nordeste brasileiro, os quais foram submetidos aos dois processos de obtenção de medidas, exame de tomografia computadorizada compondo o grupo caso e pré-moldagem constituindo o grupo controle. Após a confecção dos moldes de silicone, a prova física dos dispositivos foi realizada pelo método do estudo cego, onde os participantes não tinham conhecimento acerca da origem de cada molde. RESULTADOS: Com base na avaliação de autopercepção dos participantes quanto à técnica de obtenção dos moldes prevaleceram, no grupo controle, os conceitos Regular (53,3%), Bom (20%) e Ruim (20%), enquanto no método proposto pelo biomodelo prevaleceram os conceitos Bom (73,3%) e Ótimo (26,7%). Quanto às medidas lineares antropométricas por orelha em cada uma das formas de avaliação: Pré-molde convencional, Silicone convencional, Biomodelo e Molde proposto foram verificadas diferenças significativas (p < 0,05) entre as formas de avaliação nas variáveis ―Incisura Intertrágica – Bordo superior da Concha‖, ―Comprimento do encaixe‖ ―Profundidade de Meato Acústico Externo‖, ―Espessura do MAE‖ e do ―Volume‖ em cada uma das orelhas. Estando o coeficiente de desvio padrão inferior a metade dos valores das médias correspondentes. CONCLUSÃO: Diante do exposto, verifica-se que é possível obter moldes auriculares a partir de imagens tomográficas com resultados favoráveis.
9

Caracterização da vitrocerâmica de Li2Si2O5 em função do tratamento térmico e da análise da usinagem /

Simba, Bruno Galvão January 2019 (has links)
Orientador: Marcos Valério Ribeiro / Resumo: O dissilicato de lítio, Li2Si2O5, é um material vitrocerâmico muito utilizado na fabricação de próteses dentárias, possui grande destaque por ser biocompatível e devido suas propriedades estéticas, químicas e mecânicas, permite a confecção de próteses a partir da usinagem CAD/CAM (COMPUTER-AIDED DESIGN / COMPUTER-AIDED MANUFACTURING), com elevada precisão dimensional e a possibilidade de restauração imediata em pacientes. Os materiais comerciais são disponibilizados com estrutura Li2SiO3 (metassilicato de lítio) cujas características são: alta usinabilidade e baixa tenacidade à fratura. Após a usinagem das próteses, o material sofre tratamento térmico visando à conversão do Li2SiO3 em Li2Si2O5 (dissilicato de litio), fase de melhor tenacidade e excelente apelo estético. A compreensão desta transformação de fase, seus efeitos na usinabilidade e nas propriedades mecânicas é de interesse tecnológico e científico, pois o material será utilizado como prótese dentária após este processamento. Este trabalho visou à avaliação do Li2Si2O5 em relação as propriedades químicas, físicas e mecânicas quando submetido a diferentes tratamentos térmicos. Foram empregados métodos de caracterização por difração de raios X (DRX), microscopia eletrônica de varredura (MEV), massa específica aparente, além da determinação da dureza, tenacidade à fratura, constantes elásticas e resistência à flexão biaxial sob diferentes condições de tratamento térmico. Também foram analisados a distribuição de partí... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
10

Análise das propriedades estruturais, morfológicas e mecânicas de duas marcas comerciais diferentes de dissilicato de lítio para o sistema CAD/CAM

Tavares, Lucas do Nascimento 14 February 2017 (has links)
O objetivo deste presente estudo foi comparar duas marcas comerciais diferentes de Dissilicato de Lítio para o sistema CAD / CAM (IPS e.max CAD e Rosetta SM CAD / CAM), avaliando suas propriedades estruturais, morfológicas e mecânicas. Para avaliar as propriedades estruturais foram necessárias duas amostras de cada grupo, para serem analisadas por meio do DRX (difração de raios X). As propriedades morfológicas foram analisadas utilizando o MEV (Microscopia eletrônica de Varredura) antes e depois do tratamento térmico, e o teste de porosidade, realizado através de uma tomografia computadorizada em 3D (micro-CT). Para avaliar as propriedades mecânicas foi realizado o teste flexural de três pontos e o teste de microcisalhamento, e para isto foram selecionados dez espécimes de cada grupo para cada teste. Os valores médios de porosidade e da resistência flexural de três pontos foram analisados pelo teste t e a resistência de união obtida através do microcisalhamento foi analisada pelo teste Anova Two-way. Todos os testes usaram um nível de significância de α = 0,05. Os resultados obtidos pela análise estrutural realizada pelo DRX apresentaram picos no difractograma correspondentes ao Metassilicato de Lítio e o Dissilicato de Lítio, com intensidades semelhantes para ambos os grupos testados. Após realizar a microscopia eletrônica de varredura, não foi encontrado diferenças na morfologia dos cristais, em ambas as cerâmicas testadas, antes e depois do tratamento térmico. O teste de porosidade não mostrou diferença estatisticamente significativa entre o valor total de poros encontrados. Ambos os resultados dos testes mecânicos não apresentaram diferenças estatísticas significativas entre os grupos avaliados. Baseado nos resultados encontrados, não houve diferença entre as duas marcas comerciais testadas, em relação as suas propriedades estruturais, morfológicas e mecânicas. / The aim of the present study was to compare two different brands of lithium disilicate CAD/CAM blocks (IPS e.max CAD and Rosetta SM CAD/CAM), evaluated by structural, morphological and mechanical properties. Two specimens of each group were analyzed using x-ray diffraction (XRD) to evaluate the structures of the ceramic material. Morphologic properties were analyzed using the Scanning Electron Microscopy (SEM) before and after the heat treatment; and porosity test was performed using a 3D micro-computed tomography analyses (micro-CT). Ten specimens of each group were submitted to three-point flexure strength and microshear bond strength tests, to analyze the mechanical properties of both brands. Mean values of porosity test and three-axial flexural strength were analyzed by t Test, and the microshear bond strength was analyzed by Anova two-way. All tests used a significance level of α=0.05. The structure results performed by XDR, presented high peak positions corresponding to the standard lithium metasilicate and lithium disilicate, with similar intensities for both tested groups. The morphologic results demonstrated similar patterns of crystalline structure, before and after the heat treatment and the porosity test showed no difference between the number and size of the pores found. Both mechanical tests results did not present statistically significant differences between the samples. Based on the results, there was no difference in relation to their structural, morphological and mechanical properties, between the two commercial brands tested. / Dissertação (Mestrado)

Page generated in 0.5001 seconds