• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 405
  • 139
  • 30
  • 7
  • 7
  • 7
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • Tagged with
  • 652
  • 400
  • 367
  • 163
  • 162
  • 153
  • 143
  • 121
  • 111
  • 105
  • 104
  • 85
  • 81
  • 76
  • 70
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Avaliação de cimentos resinosos experimentais contendo diferentes concentrações de um sal derivado do difeniliodônio / Evaluation of experimental resin cements containing different concentrations of a salt derived from diphenyliodonium

Gonçalves, Luciano de Souza 17 August 2018 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T12:43:43Z (GMT). No. of bitstreams: 1 Goncalves_LucianodeSouza_D.pdf: 1422797 bytes, checksum: d08f8aa4d184071d3c75843275b3cdea (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo foi avaliar a influência da incorporação de um sal de hexafluorofosfato de difeniliodônio (DFI) nas propriedades de um cimento resinoso experimental. Uma composição à base de monômeros Bis-GMA e TEGDMA, na proporção de 1:1 mol%, foi obtida e a ela adicionadas concentrações de 0 (controle), 0,25, 0,5, 1 ou 2 mol% de DFI, definindo 5 formulações de cimentos resinosos experimentais. O sistema fotoiniciador dos materiais foi composto por 1 mol% de canforoquinona e 2 mol% de metacrilato de dimetilaminoetil. Como inibidor foi usado 0,1 mol% de hidroxibutil tolueno e 60% em peso de partículas silanizadas de vidro de bário-alumínio-silicato foram incorporadas como carga inorgânica. Depois da preparação dos cimentos foram realizados os seguintes ensaios: 1) Cinética da polimerização em tempo real em espectroscopia infravermelha, indicando também o grau de conversão dos cimentos. 2) Resistência à flexão de três pontos e módulo de elasticidade, definido pelo monitoramento do ensaio com software específico. 3) Sorção e solubilidade em água destilada (21 dias). 4) Tensão da contração de polimerização mensurada em máquina de ensaios mecânicos associada a extensômetro. 5) Dureza Knoop avaliada na base e no topo de corpos-de-prova fotoativados diretamente ou através de discos de cerâmica com 3 espessuras diferentes. A análise estatística foi realizada com significância de 5%. Os resultados mostraram que a adição do DFI influenciou as propriedades em todos os ensaios realizados. As formulações de cimentos com DFI apresentaram aumento na cinética da reação, no grau de conversão e na dureza Knoop. Houve aumento significativo na resistência à flexão e no módulo de elasticidade e redução nos valores de sorção de água e perda de massa por solubilidade. Na maioria dos grupos contendo DFI, os valores de tensão da contração de polimerização foram similares ao grupo controle, exceto o grupo 4 com 1 mol% de DFI que apresentou aumento na tensão gerada pela polimerização. Com base nos resultados obtidos foi possível concluir que a adição do DFI influenciou positivamente as propriedades dos cimentos resinosos experimentais e a concentração de 0,5 mol% parece ser a mais conveniente para a formulação desses cimentos resinosos estudados. / Abstract: The aim of this study was to evaluate the effect an onium salt -diphenyliodonium hexafluorphosphate (DPI) - on selected properties of experimental resin cement. A model Bis-GMA/TEGDMA comonomer blend (1:1 molar ratio) was obtained and DPI added at concentrations of 0 (control), 0.25, 0.5, 1 or 2 mol%, resulting in five experimental resin cements. The photoinitiator system was composed by 1 mol% of camphorquinone and 2 mol% of dimethylaminoethil methacrylate. 0.1mol% of hydroxyl butyl toluene was used as a inhibitor and the cements were loaded with a 60% mass fraction of silanated Ba-AI-Si glass fillers. The following analyzes were carried out: 1) real-time polymerization kinetics using near-infrared spectroscopy, 2) flexural strength and flexural modulus using a three-point beinding test, 3) water sorption and solubility after immersion for 21 days, 4) polymerization stress on a mechanical testing machine, and 5) Knoop hardness on the top and bottom surfaces of cement discs light-activated through different ceramic thicknesses. Data were statistically analyzed (5%). The results showed the addition of DPI had influence on the resin cements for all analyses. DPI-containing materials showed improved polymerization kinetics and degree of conversion, as well as higher hardness. A significant increase in flexural strength and modulus, and decrease in water sorption/solubility was detected. Most of materials containing DPI showed polymerization stress values comparable to the control group, except for the material containing 1 mol% of DPI (G4), which yielded higher stress. Based on these results and within the limitations of the study, it was possible to conclude that the addition of DPI has positive influence on the properties of the experimental resin cement; the 0.5 mol% concentration seems to be the most appropriate and efficient for the formulation of these resin cements. / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
202

Influencia do modo de ativação, da ciclagem mecanica e da ceramica na resistencia a tração diametral de cimentos resinosos / Influence of activation modes, mechanical fatigue and ceramic on resin cements' diametral tensile strength

Paes, Paula Nunes Guimarães 02 May 2009 (has links)
Orientador: Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:34:04Z (GMT). No. of bitstreams: 1 Paes_PaulaNunesGuimaraes_M.pdf: 8634173 bytes, checksum: 841ceeadf71622e4274b862220cdb566 (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi avaliar o efeito dos métodos de ativação e da fadiga mecânica sobre a resistência à tração diametral de cimentos resinosos duais. Pastas base e ativadora do RelyX ARC, Enforce, Nexus 2 e RelyX UNICEM foram manipuladas e inseridas em matrizes cilíndricas de silicona de adição (4 x 2 mm) e distribuídas em grupos de acordo com a técnica de ativação em: 1- Sem fotoativação (ativação química); 2- Fotoativação direta (ativação Dual); 3- Fotoativação através da cerâmica. Após armazenamento por 24 horas em água destilada a 37ºC, metade das amostras de cada grupo (n=10) foram submetidos a 30.000 ciclos mecânicos, com freqüência de 1 Hz e carga de 12 N. As amostras não cicladas permaneceram armazenadas em água destilada em estufa a 37ºC por 32 h após a manipulação, para que fossem testadas com o mesmo intervalo de tempo que as amostras cicladas. Em seguida, todas as amostras foram submetidas ao ensaio de Resistência à Tração Diametral (RTD) em máquina universal de ensaios INSTRON, com velocidade de 0,5 mm/min. Os dados de RTD (MPa) para os modos de ativação química, dual indireta e dual direta foram submetidos à análise de Variância e ao teste de Tukey (5%) e mostraram que apenas os fatores modo de ativação e cimento apresentaram interação significativa. O fator ciclagem mecânica e a interação tripla não obtiveram interação significativa. Os valores da interação dos fatores cimento e modos de ativação química, dual indireta e dual direta respectivamente foram: RelyX ARC (49,68 ± 8,42; 63,43 ± 6,92 e 55,12 ± 5,16), Enforce (49,12 ± 3,89; 56,96 ± 6,45 e 56,42 ± 8,88), RelyX ARC (28,12 ± 11,21; 40,10 ± 4,39 e 37,44 ± 6,49) e Nexus 2 (61,89 ± 11,21; 62,56 ± 10,93 e 59,26 ± 9,47). A análise dos resultados após o teste de Tukey mostrou que o cimento Nexus 2 não apresentou aumento nos valores de RTD quando ativado pela luz em relação à polimerização química. Os demais cimentos apresentaram valores maiores quando fotoativados de forma direta ou indireta, em relação aos valores alcançados pelo modo de polimerização química, com exceção do cimento RelyX ARC que obteve os mesmos valores quando ativado de forma dual direta e polimerizado quimicamente. A interposição do disco de cerâmica durante a fotoativacão alterou os valores de resistência à tração diametral apenas para o cimento RelyX ARC. A ciclagem mecânica não afetou a resistência à tração diametral de nenhum cimento resinoso dual avaliado e a composição de cada cimento resinoso dual, assim como o seu modo de ativação, foram determinantes para a obtenção da resistência à tração diametral dos mesmos. / Abstract: The aim of this study was to evaluate the effect of the activation methods and the mechanical fatigue on diametral tensile strength of dual resin cements. Base and catalyst pastes of the cements RelyX ARC, Enforce, Nexus 2 and RelyX UNICEM were mixed and inserted into cylindrical silicon moulds (4 x 2 mm) and divided in groups according to their activation methods: 1) without photoactivation (chemical activation); 2) direct curing (dual ativation); 3) light activation through porcelain disk. After being stored for 24 hours in distillated water at 37ºC, half of the samples of each group (n=10) were subjected to 30,000 mechanical cycles at 1 Hz frequency and 12 N load. The samples not cycled remained in distillated water at 37ºC for 32 h after the mixing, so they were tested with the same time that the other fatigued samples did. Then, the samples were subjected to Diametral Tensile Strength (DTS) in Instron universal machine with 0,5 mm/min speed. The data of the Diametral Tensile Strength (MPa) obtained for each cement in chemical, indirect dual and direct dual modes of activation were submeted to three-way analysis of variance and Turkey's Student Range Test (5%) and showed that only the activation methods and the cement type presented significant difference. Mechanical fatigue and triple factors interation didn't present significant difference. The data of the cement factor with chemical activation, indirect curing and direct curing was respectively: RelyX ARC (49.68 ± 8.42; 63.43 ± 6.92 e 55.12 ± 5.16), Enforce (49.12 ± 3.89; 56.96 ± 6.45 and 56.42 ± 8.88), RelyX ARC (28.12 ± 11.21; 40.10 ± 4.39 and 37.44 ± 6.49) and Nexus 2 (61.89 ± 11.21; 62.56 ± 10.93 and 59.26 ± 9.47). After Turkey's test, the data showed that the cement Nexus 2 didn't present increase in the DTS values when it was light actived comparing to chemical curing. The others cement presented higher values when directly or indirectly photoactivated compared with the values obtained with chemical activation mode. The exception was the RelyX ARC cement that obtained the same data when it was direct cured and chemical activated. The interposition of porcelain disk during the photoactivation did alter the DTS values only for the RelyX ARC cement. However, the mechanical fatigue didn't alter the DTS values of any dual resin cement tested. Each dual cement composition, as their activation mode, was fundamental in order to obtain its DTS values. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
203

Efeito da viscosidade e modo de ativação na resistencia de união a dentina, grau de conversão e resistencia flexural biaxial de cimentos resinosos duais / Effect of viscosity and activation mode on the bond strength to dentin, conversion degree and biaxial flexure strength and modulus of dual resin cements

Di Francescantonio, Marina 13 August 2018 (has links)
Orientador: Marcelo Giannini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T02:04:38Z (GMT). No. of bitstreams: 1 DiFrancescantonio_Marina_M.pdf: 16720831 bytes, checksum: ce2d1ee161bca05d6b15b3e0a9eaeedd (MD5) Previous issue date: 2009 / Resumo: As propriedades mecânicas dos cimentos resinosos são influenciadas pelo tipo e composição da matriz resinosa, tipo e tamanho das partículas de carga, modo e grau de conversão dos monômeros em polímeros, e a viscosidade é uma propriedade que está intimamente ligada a esses fatores. Os objetivos deste estudo foram avaliar a influência da viscosidade (alta e baixa) e modo de polimerização (polimerização dual e autopolimerizado) de cimentos resinosos duais (Nexus 2/ Kerr, Corp e Variolink II/ Ivoclar-Vivadent): na resistência de união da restauração à dentina (RU), no grau de conversão (GC) e na resistência flexural biaxial (RFB). Para o teste de RU, substratos dentinários de cinqüenta e seis terceiros molares humanos foram utilizados para o ensaio de microtração através da cimentação de uma peça protética do material de resina composta indireta e estes foram foto-ativados ou não segundo cada grupo experimental. Após 24 horas, os dentes foram secionados para obter espécimes em forma de palitos (de área de secção transversal de 1.0 mm²), que foram testados em tração a uma velocidade de 0,5 mm/ mim (4411/Instron). Os resultados foram analisados por ANOVA 3 fatores e teste Tukey (p=0,05). Para a análise do GC, os cimentos foram aplicados na superfície da unidade de reflectância total atenuada acoplada ao espectrômetro infravermelho (Nicolet Instrument Corp, Madson, Wisconsin, EUA) sendo foto-ativados ou não. Espectros foram obtidos após 5 minutos e 24 horas. O cálculo do grau de conversão foi realizado através da análise da mudança na proporção entre as alturas dos picos das ligações duplas de carbono alifática e aromática. Os dados foram submetidos a ANOVA 3 fatores e teste de Tukey (p=0,05). Para o ensaio de RFB, noventa e seis discos de cimentos resinosos (0,5mm de espessura/ 6mm de diâmetro) foram preparados utilizando moldes de silicone de adição (n=12) e foram foto-ativados ou não segundo os grupos experimentais. Após 5 dias, os discos foram testados em dispositivos de ensaio de flexão biaxial em máquina de ensaio universal (1,27 mm/min, Instron 5844) e os dados analisados estatisticamente por ANOVA 3 fatores e teste Tukey(p=0,05). Para a RU, a polimerização dual (foto + autopolimerização) aumentou significantemente os valores médios para os cimentos resinosos em baixa viscosidade para ambos os cimentos resinosos duais utilizados no estudo. Em relação o GC, a foto-ativação e quando o GC foi mensurado após 24 horas, aumentaram significativamente o GC para ambos os cimentos resinosos. A versão em baixa viscosidade apresentou maior GC que os em alta viscosidade, para as duas formas de polimerização. No teste RFB, a foto-ativação aumentou significantemente a resistência e módulo de flexão. A versão em alta viscosidade quando foto-ativada mostrou maior resistência flexural que em baixa viscosidade, enquanto a viscosidade não alterou os valores médios de módulo flexural. Pode-se concluir que a foto-ativação é necessária durante a cimentação de restaurações indiretas, para garantir adequadas propriedades físico-químicas, e a utilização de cimentos resinosos em diferentes viscosidades pode modificar os valores médios de RFB, GC e RU à dentina. / Abstract: The mechanical properties of resin cements may be influenced by the type and monomer composition, type and filler size, mode, and degree of conversion, which are all associated with resin viscosities. The aim of this study was to evaluate the influence of resin cement viscosity (high and low) (Nexus 2/ Kerr, Corp and Variolink II/ Ivoclar-Vivadent) and the curing mode (dual and chemical activation) on the bond strength to dentin, on the degree of conversion and biaxial flexural strength. For microtensile bond strength test, two bonding agents and their respective resin cement, occlusal dentin surfaces of fifty-six human third molars were used for the testing and the resin cements were applied to pre-cured resin composite discs, which were fixed to dentin surfaces, simulating an indirect restoration. The restored teeth were either light-activated or allowed to self-cure, according to experimental groups. After 24 hs, the teeth were sectioned to obtain bonded beams specimens (1.0 mm²). Each specimen was tested in tension at a crosshead speed of 0.5 mm/min (4411/Instron). Data (MPa) was analyzed by 3- way ANOVA and Tukey's Tukey's test (p=0.05). To evaluate the degree of conversion, the resin cements were applied to surface of a horizontal attenuatedtotal- reflectance unit (Nicolet Instrument Corp, Madson, Wisconsin, EUA) and were polymerized using one of two conditions: self-cure (SC) or direct light exposure (600 mW/cm2, XL3000/3M ESPE) and infrared spectra were obtained after 5 minutes and 24 hours. The degree of conversion was calculated using standard techniques of observing changes in aliphatic-to-aromatic peak ratios pre- and postcuring. Data were analyzed by 3-way repeated measure ANOVA and Tukey's test (p=0.05). For the biaxial flexural strength, forty-eight resin cement discs of each product (0.5 mm thick and 6.0 mm in diameter) were created using silicon impression material molds (n=12) and were either light activated or not, according to experimental groups. After 5 days, the specimens were subjected to the biaxial flexure test in a universal testing machine (1.27 mm/min, Instron 5844) and the data ware statistically analyzed by 3-way ANOVA and Tukey's post-hoc test (p=0.05). For bond strength testing, the dual curing mode increased the bond strength for the low viscosity resin cements for both dual resin cement used in this study. For the degree of conversion, the light activation, after 24h, significantly increased the degree of conversion for both resin cements, and the low viscosity version from dual cure or self-cured groups exhibited higher degree of conversion than high viscosity version. Regarding biaxial flexural strength, the light-activation significantly increased flexural strength and modulus, and the high viscosity versions of dual cure groups exhibited higher flexural strength than their low viscosity versions, while the viscosity of resin cements did not influence the modulus. In conclusion, the light-activation of dual resin cements is required in indirect restorations, to provide proper mechanical and chemical properties, and the use of resin cements with different viscosities may change the bonding biomechanical characteristics of indirect restorations. / Mestrado / Dentística / Mestre em Clínica Odontológica
204

Estudo comparativo da adaptação marginal entre copings metalicos, In-Ceram alumina e e.max Press, antes e apos a cimentação / Comparative study of the adaptation between metallic copings, In-Cream alumina and e.max Press, before and after cementation

Silva, Ligia Luzia Buarque e 02 October 2010 (has links)
Orientador: Alexandre Brait Landulpho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T12:55:15Z (GMT). No. of bitstreams: 1 Silva_LigiaLuziaBuarquee_D.pdf: 1564989 bytes, checksum: 2ab1092a979d410002dd2a5d9a0cc0b8 (MD5) Previous issue date: 2010 / Resumo: Esse estudo avaliou a adaptação marginal entre copings metálicos, In-Ceram e e.max Press, antes e após cimentação em preparos sobre dentes bovinos, utilizando dois tipos de cimento resinosos. Noventa incisivos bovinos foram fixados em resina acrílica ativada quimicamente e as porções coronárias foram preparadas para coroa total, com expulsividade de 8o e término cervical em ombro. Trinta copings foram confeccionados para cada tipo de material, onde foram adaptados sobre os preparos com carga estática de 9 Kgf por 1 minuto e a discrepância marginal foi medida com microscópio de mensuração (STM). Em seguida, 15 amostras para cada tipo de coping foram cimentadas sobre os dentes com agente resinoso convencional, e mais 15 amostras para cada coping foram cimentadas com agente autoadesivo com uma carga estática de 9 Kgf por 7 minutos e novamente a discrepância marginal foi medida. Os resultados mostraram que antes da cimentação, houve diferenças significativas (p<0,05) no desajuste marginal entre os sistemas, sendo que o e.max Press apresentou maior desajuste. Após a cimentação os copings de metal e In-Ceram não apresentaram diferenças significativas (p>0,05) entre os cimentos. O sistema e.max Press apresentou um maior desajuste (p<0,05) quando cimentado com agente resinoso convencional. Quando os sistemas foram cimentados com agente resinoso convencional, o menor desajuste foi encontrado no metal (p<0,05), sendo que não houve diferenças significativas (p>0,05) entre os outros dois sistemas. Quando cimentados com o agente autoadesivo, não apresentaram diferenças significativas (p>0,05) / Abstract: This study evaluated the marginal adaptation of metal copings, In-Ceram and Press, before and after cementation in preparations on bovine teeth using two types of resin cement. Ninety bovine incisors were embedded in resin and the coronal portions of the teeth were prepared to receive complete crowns with 8o of tapering and right shoulder. Thirty crowns were fabricated for each coping. The crowns were then seated on the teeth with 9 Kgf static loads for 1 minute and the marginal discrepancy was mensured using a microscopic (STM). Afterwards, the copings were removed and fifteen samples of each coping were luted on the teeth with resin cement, and fifteen with self-adhesive resin cement applied 9 Kgf static loads for 7 minutes and the marginal discrepancy was mensured again. The results showed that before to cementation, there were significant differences (p <0.05) in the marginal fit between the systems, and the e. max Press show higher discrepancy. After cementing the metal copings and In-Ceram showed no significant differences (p>0.05) between the cements. The system e.max Press showed a significant discrepancy higher (p <0.05) when cemented with conventional resin. When the systems were cemented with resin conventional, the lowest discrepancy was found in the metal (p <0.05), with no significant differences (p> 0.05) between the other two systems. When cemented with the self agent adhesive, no significant differences (p> 0.05) / Doutorado / Protese Dental / Doutor em Clínica Odontológica
205

Resistência de união entre uma cerâmica e o esmalte de dente bovino, efetuada por diferentes sistemas adesivos e técnicas de cimentação / Bond strength between a ceramic and bovine tooth enamel, made by different adhesive systems and luting techniques

André Tomazini Gomes de Sá 11 October 2011 (has links)
O objetivo no presente trabalho foi avaliar a resistência da união adesiva de uma cerâmica vítrea (IPS e.max Press) fixada sobre o esmalte de dentes bovinos. Empregaram-se dois métodos de cimentação um, com a fotoativação prévia do adesivo; outro, com a fotoativação simultânea do adesivo e do cimento compósito após a fixação do disco cerâmico, que tinha 5mm de diâmetro e 2mm de espessura. Pela combinação de dois sistemas adesivos fotopolimerizáveis (Optibond FL e Single Bond 2), e de dois cimentos (Variolink II e RelyX ARC), um fotopolimerizável e outro de cura dupla associados às duas técnicas de cimentação formaram-se oito condições de cimentação. As amostras foram submetidas a ensaio de cisalhamento pela técnica do fio de aço. Com base nos valores encontrados nas condições estabelecidas, após o respectivo tratamento estatístico, foi possível concluir que: a) a técnica de cimentação com fotopolimerização simultânea do adesivo com o cimento produziu índices de resistência superiores aos obtidos pela técnica de fotopolimerização prévia do adesivo; b) A combinação do adesivo Single Bond 2 com o cimento Variolink II resultou em menores valores de resistência adesiva, diante das outra três combinações de cimentos e adesivos formadas. / The aim of this study was to evaluate the strength of adhesive bonding of a glass-ceramic (IPS e.max Press) fixed on the enamel of bovine teeth. There were used two methods of cementation one in which the adhesive was pre-cured, and another in which the photopolymerization of the adhesive and composite cement was performed simultaneously after the fixing of ceramic disc, which was 5mm in diameter and 2mm thick. Through a combination of two light cured adhesive systems (Single Bond and FL Optibond 2) and two resin cements (Variolink II and RelyX ARC), one light-cured and another dual-cured associated with the two luting techniques eight conditions of cementation were formed. The samples were subjected to shear test technique. Under the established conditions, after statistical treatment of results the following conclusions could be drawn: a) the cementation technique with simultaneous curing of the adhesive with cement produced resistance rates higher than those obtained by the technique of pre-curing the adhesive; b) the combination of adhesive Single Bond 2 with cement Variolink II resulted in lower bond strength, in comparison with the other three combinations of cements and adhesives formed.
206

Influência das soluções de limpeza dentinária na resistência de união de pinos de fibra de vidro / Influence of dentinary cleaning solutions in the resistance of glass fiber pin union

Macedo, Patrícia Almeida da Silva de 26 March 2018 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-10-03T19:48:30Z No. of bitstreams: 2 Patricia_Macedo2018.pdf: 792975 bytes, checksum: a12fcccb5877a843f32aabd7aa561149 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-10-03T19:48:30Z (GMT). No. of bitstreams: 2 Patricia_Macedo2018.pdf: 792975 bytes, checksum: a12fcccb5877a843f32aabd7aa561149 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-26 / The purpose of this study was to evaluate, in vitro, the effect of ozonated water as a cleaning solution on the bond strength of glass fiber pins. Ninety-eight bovine roots were used, divided randomly into 7 groups, according to the irrigation and dentin cleaning solution: HP/HP – 2,5% sodium hypochlorite, AD/AD - distilled water;; CHX/CHX - 2% chlorhexidine; AO/AO - ozonated water 4 ppm; HP / AD – 2,5% sodium hypochlorite and distilled water; HP / CHX - 2.5% sodium hypochlorite and 2% chlorhexidine and, HP / AO – 2,5% sodium hypochlorite and 4 ppm ozonated water. The root canals were prepared endodontically according to the irrigating solutions of each group and stored in distilled water. After 7 days, they were cleared and cleaned according to cleaning solutions. The fiberglass pins were cemented using self-adhesive cement. After 7 days of cementation, the roots were sectioned (6 discs each) and submitted to the push-out test. The analysis of the type of fracture was done with a stereoscopic magnifying glass of 4,5x. Data were analyzed statistically by ANOVA and Tukey tests with a significance level of 5%. The highest mean of push-out union strength in the cervical third was obtained in the AO (11,67), HP (11,21) and HP / AO (9,71) groups, maintaining this same tendency in the middle and apical thirds. The AO and HP were the most relevant solutions in the treatment of root dentin. / O propósito deste estudo foi avaliar, in vitro, o efeito da água ozonizada como solução de limpeza sobre a resistência de união de pinos de fibra de vidro. Foram utilizadas 98 raízes bovinas n = (14), divididas aleatoriamente em 7 grupos, de acordo com a solução irrigadora e de limpeza dentinária: HP/HP - hipoclorito de sódio 2,5%; AD/AD - água destilada; CHX/CHX - clorexidina 2%; AO/AO - água ozonizada 4 ppm; HP/AD - hipoclorito de sódio 2,5% e água destilada; HP/CHX - hipoclorito de sódio 2,5% e clorexidina 2%, e HP/AO - hipoclorito de sódio 2,5% e água ozonizada 4 ppm. Os canais radiculares foram preparados endodonticamente de acordo com as soluções irrigadoras de cada grupo e armazenados em água destilada. Após 7 dias, foram desobturados e limpos de acordo com as soluções de limpeza. Os pinos de fibra de vidro foram cimentados, utilizando cimento resinoso autoadesivo. Após 7 dias da cimentação, as raízes foram seccionadas (6 discos cada) e submetidas ao teste de push-out. A análise do tipo de fratura foi feita com uma lupa estereoscópica de 4,5x. Os dados obtidos foram analisados estatisticamente pelos testes ANOVA e Tukey com nível de significância 5%. A maior média de resistência de união push-out no terço cervical foi obtida nos grupos AO (11,67), HP (11,21) e HP/AO (9,71), mantendo esta mesma tendência nos terços médio e apical. A AO e HP foram as soluções mais relevantes no tratamento da dentina radicular.
207

Resistência de união à cerâmica de cimentos resinosos experimentais contendo um sal derivado do difeniliodônio / Microtensile bond strength to ceramic of experimental resin cements containing a diphenyliodonium derived salt

Palialol, Alan Rodrigo Muniz, 1984- 04 December 2013 (has links)
Orientador: Giselle Maria Marchi Baron / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T19:05:45Z (GMT). No. of bitstreams: 1 Palialol_AlanRodrigoMuniz_M.pdf: 12504444 bytes, checksum: a578af5941e733ad7dd18243b934355c (MD5) Previous issue date: 2013 / Resumo: O objetivo desse estudo foi avaliar a resistência de união de cimentos resinosos experimentais contendo diferentes concentrações do sal de hexafluorfosfato de difeniliodônio (DPIHFP) à cerâmica reforçada por dissilicato de lítio, com ou sem aplicação do adesivo após o uso do silano. Para isso, cinco diferentes formulações de cimento foram confeccionadas utilizando como base os monômeros Bis-GMA e TEGDMA (na proporção 1:1 em massa) e 60% em peso de partículas silanizadas de vidro de bárioalumínio- silicato. O sistema fotoiniciador foi composto por 1 mol% de canforoquinona (CQ), 2 mol% de metacrilato de dimetilaminoetil (DMAEMA) e diferentes concentrações de DPIHFP: 0; 0,25; 0,5; 1 e 2 mol%, definindo assim, cinco formulações de cimentos resinosos experimentais. Como inibidor foi acrescido à mistura uma quantidade de 0,1 mol% de hidroxitolueno butilado e 60% em peso de partículas silanizadas de vidro de bário-alumínio-silicato foram incorporadas como carga inorgânica. Diante disso, a cimentação foi realizada com ou sem a aplicação do adesivo (Adper Scotchbond Multi- Purpose - Bond) estabelecendo assim, 12 grupos (n=7), sendo avaliados os cinco cimentos experimentais formulados e um cimento comercial (RelyX ARC). Foram confeccionados 84 espécimes de cerâmica IPS e.max (10 mm de comprimento x 10 mm de largura x 3 mm de espessura) e divididos, aleatoriamente, entre os 12 grupos previamente estabelecidos. Para todos os grupos foi realizado o condicionamento ácido da cerâmica (ácido hidrofluorídrico a 10%, 20 s) e aplicação de silano (RelyX Ceramic Primer). Logo após, os espécimes foram cimentados a blocos de resina fotopolimerizável Filtek Z250 (10 mm de comprimento x 10 mm de largura x 5 mm de espessura), utilizando os diferentes cimentos de acordo com o respectivo grupo, sob carga estática de 500 g, por 1 minuto. Para os grupos com utilização de adesivo, este foi aplicado 1 minuto após a aplicação do silano, sendo fotoativado através da cerâmica com LED 3a geração (Bluephase G2) a 1200 mW/cm2 juntamente com o cimento resinoso por 60 segundos. Após armazenamento (sob umidade relativa) em estufa por 24 horas a 37oC, as amostras foram seccionadas perpendicularmente à interface de união, gerando palitos de 1 mm2 (30 palitos por bloco) que foram submetidos ao ensaio de microtração em máquina de ensaio universal EMIC com velocidade de 0,5 mm/min. Foi realizado análise do padrão de fratura em lupa estereoscópica (Leica MZ75) com aumento de 40x e uma imagem representativa de cada padrão foi realizada em microscopia eletrônica de varredura. Os dados foram analisados através de Análise de Variância a dois critérios e teste Tukey, a um nível de significância de 5%. O cimento resinoso dual RelyX ARC apresentou os maiores valores de união, para os grupos com ou sem aplicação de sistema adesivo. Nos grupos com aplicação do sistema adesivo, os cimentos experimentais não diferiram estatisticamente entre si quanto à resistência de união. Nos grupos sem aplicação de adesivo, o cimento contendo 2mol% de DPIHFP obteve os menores valores de união. A aplicação do adesivo propiciou maiores valores de união somente para os cimentos RelyX ARC e DPIHFP 2mol%. De acordo com os resultados, pode-se concluir que a adição do sal de DPIHFP não foi capaz de aumentar os valores de união dos cimentos experimentais. O sistema de dupla ativação apresentou resistência de união à cerâmica superior aos cimentos experimentais fotoativados e a aplicação do adesivo promoveu o aumento dos valores de união apenas para os cimentos RelyX ARC e DPIHFP 2mol% / Abstract: The aim of this study was to evaluate the bond strength of experimental resin cements (ERCs) containing different concentrations of Diphenyliodonium Hexafluorphosphate (DPIHFP) salt to a lithium disilicate ceramic with or without the adhesive application after silane treatment. For this purpose, five ERCs were prepared using a Bis-GMA/TEGDMA (1:1 molar ratio) base compound with a 60% mass fraction of silanated Barium-Aluminum-Silicate glass fillers. The photoinitiator system was composed by 1 mol% of camphorquinone (CQ) 2 mol% of dimethylaminoethil methacrylate (DMAEMA) and different DPIHFP concentrations of 0, 0.25, 0.5, 1 or 2 mol%, resulting in five ERCs. As an inhibitor, 0.1mol% of hydroxyl butyl toluene was used. Therefore, the fixing protocol was performed with or without the application of adhesive (Scotchbond Multi-Purpose Adper - Bond) thereby establishing, 12 groups (n = 7), evaluating the five experimental resin cements and a commercial cement (RelyX ARC). Eighty four IPS e.max Press ceramic specimens (10 mm lenght x 10 mm width x 3 mm thickness) were fabricated and randomly divided among the 12 groups previously established. All the groups were etched with 10% hydrofluoric acid for 20 seconds and silane couple agent applied on the bond surface. After that, the specimens were fixed to photoactivated composite resin Filtek Z250 blocks (10 mm lenght x 10 mm width x 5 mm thickness), using different cements according to the respective group under static load of 500 g per one minute. For groups with adhesive application, this was applied 1 minute after applying the silane being cured by a third generation LED (Bluephase G2) together with the resin cement for 60 seconds. After storage for 24 hours at 37oC, the samples were sectioned perpendicular to the bond interface to obtain 1 mm2 sectional area beams (30 beams per sample) and submitted to a microtensile bond strength test in a universal testing machine EMIC, at a crosshead speed of 0.5 mm/min. The failure mode was analyzed by a stereomicroscope (Leica MZ75) at 40x magnification and one example of each type of failure mode was analyzed in scanning electron microscopy. Data were analyzed using ANOVA two criteria (ANOVA two-way) and Tukey test at a significance level of 5%. The dual resin cement RelyX ARC showed the highest bond strength values using or not the adhesive system. In groups with adhesive system, the ERCs were not statistically different from each other on the bond strength values to ceramics. In groups without adhesive system, the 2mol% of DPIHFP resin cement obtained the lowest bond strength values. The adhesive application led to higher bond strength values only for RelyX ARC and 2mol % DPIHFP resin cements. According to results, it can be concluded that the addition of DPIHFP salt was not able to increase the bond strength values of the experimental cements. The dual activation system showed higher values of bond strength when compared to photoactivated ERCs and adhesive system protocol increased the bond strength values only for the RelyX ARC and 2mol% DPIHFP resin cements / Mestrado / Dentística / Mestre em Clínica Odontológica
208

Avaliação da discrepância marginal vertical de copings de zircônia, antes e após a cimentação / Evaluation of vertical marginal discrepancy of zirconia copings, before and after cementation

Lameira, Deborah Pacheco, 1982- 19 August 2018 (has links)
Orientador: Wilkens Aurelio Buarque e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T14:47:24Z (GMT). No. of bitstreams: 1 Lameira_DeborahPacheco_M.pdf: 1236385 bytes, checksum: d60f94ad13b9c4dba0926134be673c29 (MD5) Previous issue date: 2011 / Resumo: O objetivo deste trabalho foi avaliar a discrepância marginal vertical de copings zircônia, Zirkonzahn® CAD/CAM (Computer Aided Design/Computer Aided Manufacturing). Foram confeccionados 30 copings de zircônia tetragonal policristalina estabilizada por ítrio (Y-TZP) do sistema CAD/CAM e 30 copings metálicos (grupo controle). Os copings foram cimentados com dois tipos de cimento: fosfato de zinco (SS White®) e cimento resinoso (Rely X ARC®, 3M¿ ESPE¿), constituindo dois subgrupos de 15 unidades cada. O desajuste marginal foi mensurado antes e após a cimentação com auxílio de um microscópio comparador 3D computadorizado em aumento de 120 vezes. Os dados foram submetidos à análise de variância e ao teste t de Student com nível de significância de 5%. Os resultados mostram que antes da cimentação os copings de zircônia apresentaram média de desajuste marginal maior do que o grupo controle. Após a cimentação, a média de desajuste dos copings de zircônia (89,71 ?m) foi maior do que o a do grupo controle (40,04 ?m) quando cimentados com cimento de fosfato de zinco, porém não houve diferenças significativas entre os dois materiais quando cimentados com cimento resinoso (metal: 48,88 ?m e zircônia: 47,62 ?m). Quando comparados os cimentos estudados, não houve diferença significativa de desajuste entre os dois cimentos para o grupo controle (fosfato de zinco: 40,04 ?m e resinoso: 48,88 ?m), enquanto que para os copings de zircônia o desajuste marginal dos cimentados com cimento de fosfato de zinco (89,71 ?m) foi maior do que os cimentados com cimento resinoso (47,62 ?m). Os resultados sugerem que o cimento resinoso é mais indicado para cimentação dos copings de zircônia, pois apresentou menor desajuste vertical quando comparado com cimento de fosfato de zinco / Abstract: The aim of this study was to evaluate the marginal vertical discrepancy of zirconia copings, Zirkonzahn ® CAD / CAM (Computer Aided Design / Computer Aided Manufacturing).Thirty copings of (Y-TZP) yttrium tetragonal zirconia polycrystalline were fabricated by the CAD / CAM system and thirty metal copings served as control group. The copings were cemented with zinc phosphate (SS White ®) and resin cement (Rely X ARC ®, 3M ¿ ESPE ¿), and assigned four groups of 15 units each. The marginal misfit was measured before and after cementation with a computerized microscope at a magnification of 120 X. Data were submitted to ANOVA and Student's t-test at a significance level of 5%. Before the cementation, the marginal discrepancy found for zirconia copings was greater than that observed for the control. After the cementation with zinc phosphate the marginal gap of zirconia copings (89.71 ?m) was larger than that found for the control (40.04 ?m). No significant difference was found in marginal discrepancy between the systems after cementation with resin cement (metal: 48.88 ?m and zirconia: 47.62 ?m). When the two cements are compared, there was no difference in the marginal discrepancy for the control (zinc phosphate: 40.04 ?m and resin cement: 48.88 ?m). However, for the zirconia copings, the marginal discrepancy was greater when cemented with zinc phosphate (89.71 ?m) than when cemented with resin cement (47.62 ?m). The results suggest that the resin cement is more suitable for cementation of zirconia copings, as presented lower marginal vertical discrepancy than zinc phosphate cement / Mestrado / Protese Dental / Mestre em Clínica Odontológica
209

Avaliação in vitro de restaurações indiretas de composito em dentes deciduos : estudo do tratamento do substrato e agentes de fixação

Borges, Ana Flavia Sanches 21 February 2005 (has links)
Orientador: Regina Maria Puppin-Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:12:27Z (GMT). No. of bitstreams: 1 Borges_AnaFlaviaSanches_M.pdf: 3516462 bytes, checksum: a51b845dc96d230cbc181dac6262187f (MD5) Previous issue date: 2005 / Resumo: As restaurações indiretas de compósito são uma das alternativas na clínica odontopediátrica, pois, proporcionam a redução da duração da sessão clínica, além da possibilidade da diminuição da contração de polimerização inerente ao pequeno volume do agente de fixação resinoso. Em casos de dentes tratados endodonticamente, o desempenho das restaurações ¿adesivas¿ não se encontra bem estabelecido, e estas são de extrema importância uma vez que a falha nas restaurações das coroas de dentes submetidos à terapia pulpar pode significar a perda do tratamento endodôntico. Assim, os objetivos desta dissertação fundamentada em dois artigos foram: (1) avaliar a adaptação marginal inicial de restaurações tipo onlay de compósito em dentes decíduos previamente submetidos ou não à irrigação com hipoclorito de sódio 1% (NaOCl 1%) e cimentados com dois sistemas resinosos para fixação (EnForce e Rely X), (2) avaliar os efeitos do tratamento com NaOCl 1% e dois agentes resinosos de fixação na recuperação da força compressiva de dentes decíduos restaurados com onlays de compósito e analisar os padrões de fratura produzidos quanto ao grau de severidade. No estudo 1, a amostra foi constituída de quarenta molares decíduos hígidos, restaurados com restaurações indiretas tipo onlay de compósito resinoso, divididos em grupos conforme os dois fatores de variação estabelecidos para o estudo: irrigação com (NaOCl 1%) e agentes de fixação resinosos (EnForce e Rely X). Para a análise da adaptação marginal foi aplicada uma solução corante nas margens da restauração, e, as áreas coradas foram consideradas como presença de fendas marginais. O software Image Tool 3.0 foi utilizado para a mensuração linear do comprimento das fendas. No estudo 2, trabalhou-se com a mesma amostra do estudo 1, com o acréscimo do grupo controle composto de dentes hígidos, totalizando cinqüenta dentes. Todos os espécimes foram submetidos ao teste mecânico de compressão, os tipos de fratura foram classificados macroscopicamente quanto aos graus de severidade e os sítios de fratura foram analisados em microscopia eletrônica de varredura a título de ilustração. No estudo 1, não houve diferença estatisticamente significativa quanto à quantidade de fendas encontrada entre os grupos (p>0.05), porém, o risco relativo de ausência de fenda revelou que alguns grupos apresentaram maior chance de ausência de fenda que outros, sendo que o grupo com maior risco relativo foi o grupo tratado com hipoclorito e fixado com EnForce (RR=1.56). No estudo 2, não houve diferença quanto aos valores de força compressiva entre os grupos estudados (p>0.05), consequentemente, os grupos experimentais apresentaram recuperação da resistência à compressão, alcançando valores que não diferiram daqueles do grupo controle. Quanto ao grau de severidade das fraturas, os grupos experimentais mostraram os tipos mais severos de fratura, enquanto o grupo controle apresentou os tipos menos severos. Assim, a técnica restauradora indireta de compósitos resinosos em dentes decíduos com preparos cavitários complexos e submetidos à simulação do procedimento de irrigação endodôntica, apresentou adequada adaptação marginal inicial e foi capaz de recuperar a resistência à carga compressiva em relação aos dentes hígidos / Abstract: The indirect restorations are an interesting restoration procedure in the pediatric dentistry clinic, because this leads to a reduced chairside time, besides would decrease polymerization shrinkage due to the resin luting agent lower volume. To endodontically treated teeth, the performance of adhesive restorations has already not been established, and this is extremely important since if restorations upon crowns failures, the pulp therapy can be lost. Then, the objectives presented in the dissertation form based in two articles were: (1) to evaluate the earlier marginal adaptation of onlay composite restorations in primary teeth subjected or not to 1% sodium hypochlorite (1% NaOCl) irrigation and bonded with two types of resin luting agents (EnForce e Rely X); (2) to evaluate the compressive strength of experimental groups studied in the first research and compare them with the sound teeth, besides to evaluate the types of fractures regarding to severity degree. In the first study, the sample was accomplished by forty sound molars restored with indirect onlay composite restorations. The teeth were divided into groups according the two factors of variations established in this study: 1% NaOCl irrigation and resin luting agents (EnForce and Rely X). To analyze the marginal adaptation a dye solution was applied upon restorations margins, and the dyed margins were considered as marginal gaps presence. TheImage Tool 3.0 software was used to measure the linear length. In the second study, the same sample of the study 1 was used with the addition of the control group accomplished the sound teeth, with the total of 50 teeth. All specimens were subjected to compression mechanic test, and the fractures types were macroscopically classified related to the severity degree. In the first study, there were no statistically difference related quantity of gaps among the groups (p>0.05), however, some groups showed the relative risk tendency of no gap higher than others, and the group treated with NaOCl and fixed EnForce (RR=1.56) produced the higher relative risk tendency. In the second study, there were no statistically differences related to compressive force values among any studied groups (p>0.05), consequently, the experimental groups had similar values to sound teeth. Concerning the severity of fractures, the experimental groups showed the most severe types of fractures, while the control group showed the lower severe types. Then, the composite indirect restored technique showed acceptable earlier marginal adaptation and recovery of the compressive strength of teeth with complex prepares and submitted to endodontic irrigation procedure / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
210

Avaliação de diferentes cimentos endodonticos quanto ao escoamento, obturação e selamento marginal em canais laterais artificialmente produzidos em dentes humanos

Almeida, José Flávio Affonso de, 1979- 18 February 2005 (has links)
Orientador: Alexandre Augusto Zaia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:22:25Z (GMT). No. of bitstreams: 1 Almeida_JoseFlavioAffonsode_M.pdf: 1181131 bytes, checksum: 0782b1ca6fa876770da95f2cac650895 (MD5) Previous issue date: 2005 / Resumo: Este estudo teve como objetivo avaliar capacidade de escoamento, obturação e selamento marginal contra infiltração de corantes em canais laterais artificialmente produzidos em dentes humanos, utilizando seis diferentes cimentos empregados em Endodontia (Pulp Canal Sealer (EWT), Endométhasone, Target H&D, Sealapex, Sealer 26 e AH Plus). O escoamento dos cimentos foi testado seguindo as normas internacionais n.° 57 da American Dental Association (ADA) e 6876 da International Organization for Standardization (ISO). Com auxílio de brocas de 0,1mm de diâmetro, dois canais laterais foram confeccionados em 82 raízes dentais, sendo um no terço médio e outro no terço apical do canal radicular. As raízes foram obturadas com a técnica da condensação lateral e radiografadas digitalmente no sentido vestíbulo-lingual. Após 48h, as raízes foram imersas em tinta nanquim por 24h e diafanizadas. Os testes de escoamento dos cimentos demonstraram que os cimentos Pulp Canal Sealer (EWT), AH Plus e Target H&D foram capazes de cumprir com as recomendações 57 da ADA e 6876 da ISO. Os cimentos Sealapex e Sealer 26 cumpriram com a recomendação da ADA mas não cumpriram com a ISO. O Endométhasone não apresentou o escoamento mínimo exigido pelas duas recomendações. Os preenchimentos dos canais laterais analisados através de radiografia digital, diafanização e infiltração de corantes apresentaram índices estatisticamente semelhantes para todos os cimentos testados. A comparação estatística entre os índices de infiltração de corante dos cimentos demonstrou que os cimentos AH Plus e Sealapex permitiram menos infiltração do que o cimento Pulp Canal Sealer (EWT). A análise radiográfica não foi eficiente em demonstrar a obturação dos canais laterais artificiais em aproximadamente 20% dos casos. As taxas de escoamento requeridas pelas normas 57 da ADA e 6876 da ISO não demonstraram relação direta com a capacidade dos cimentos testados em obturar canais laterais artificiais de 0,1mm de diâmetro / Abstract: The aim of this study was to evaluate the flow rate, the filling and dye leakage in artificial lateral canals using 6 different sealers (Pulp Canal Sealer (EWT), Endométhasone, Target H&D, Sealapex, Sealer 26 e AH Plus). The flow rate was analyzed through 57 American Dental Association (ADA) and 6876 International Organization for Standardization (ISO) specifications. Two lateral canals were produced in the medium and apical third of 82 dental roots with 0,1mm drills. Lateral condensation and the sealers were used to fill the root canals and buccolingual digital radiographs were performed. After 48h the roots were immersed in Indian ink and cleared in methyl salicylate. Pulp Canal Sealer (EWT), AH Plus and Target H&D were able to accomplish with 57 ADA and 6876 ISO specifications. Sealapex and Sealer 26 accomplished with 57 ADA specification but not with 6876 ISO. Endométhasone were not able to accomplish with any specifications. Lateral canal fillings evaluated by radiograph, clearing technique and dye leakage were statistically similar for the 6 sealers tested. The dye leakage demonstrated that AH Plus and Sealapex permitted less leakage than Pulp Canal Sealer (EWT). This data were statistically significant. The radiograph was not able to demonstrate the filling of lateral canal in approximately 20%. There is no correlation of the flow rate required by the 57 ADA and 6876 ISO specifications and the sealers ability to fill 0.1mm artificial lateral canals / Mestrado / Endodontia / Mestre em Clínica Odontológica

Page generated in 0.1953 seconds