• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 112
  • 37
  • 15
  • 9
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 245
  • 43
  • 41
  • 23
  • 22
  • 22
  • 21
  • 21
  • 19
  • 19
  • 19
  • 17
  • 16
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Sobre a modelagem numérica da difusão de cloretos no concreto: uma abordagem pelo método dos elementos de contorno com aplicação de modelos de confiabilidade e otimização / On the numerical modeling of diffusion of chlorides in concrete: an approach by the boundary element method with the application of reliability and optimization models

Pellizzer, Giovanni Pais 18 April 2019 (has links)
O principal mecanismo de transporte de íons cloreto pelos microporos do concreto é a difusão. Em um dado instante do processo difusivo, quando a concentração de cloretos na interface concreto/armadura atinge um valor limite, ocorre a despassivação das armaduras. É neste instante que se encerra a etapa de iniciação e onde se inicia a etapa de propagação da corrosão. Considerando-se que após o início da etapa de propagação a segurança estrutural decai rapidamente, devido aos diversos mecanismos deletérios ocasionados pela corrosão, é fundamental prever adequadamente quando se dará o seu início. Existem disponíveis na literatura diversos métodos para a análise da etapa de iniciação. Contudo, poucos utilizam o método dos elementos de contorno (MEC) para este fim. Além disso, devido à elevada aleatoriedade presente neste fenômeno, uma abordagem sob um ponto de vista probabilístico apresenta grande potencial para um tratamento adequado do problema. Por fim, objetivando encontrar configurações de projeto propícias a manutenção de um dado nível de segurança mínimo durante toda a vida útil estrutural, podem ser empregados modelos de otimização sob incertezas. Assim, o presente trabalho tem por objetivo apresentar uma formulação baseada no MEC que torne possível a análise determinística, probabilística e de otimização da etapa de iniciação para problemas de difusão no concreto em regime transiente. É descrita a formulação do problema e o esquema de resolução do mesmo, implementados computacionalmente. Exemplos de aplicação são apresentados validando e mostrando a eficiência das formulações adotadas. Destacam-se as limitações de soluções analíticas, as potencialidades da solução numérica e a grande influência que as condições de contorno exercem sobre o fenômeno. / Diffusion is the main transport mechanism of chloride ions through the micropores of concrete. At a given moment of the diffusive process, when the chloride concentration at the concrete/reinforcement interface reaches a threshold level, reinforcement depassivation occurs. At this point, the initiation stage ends and the corrosion propagation stage begins. Considering that after the start of the propagation stage the structural safety decays rapidly, due to the various deleterious mechanisms caused by corrosion, it is essential to adequately predict when it will start. Several methods for the analysis of the initiation stage are available in the literature. However, few of then use the boundary element method (BEM) for this purpose. Moreover, due to the high randomness present in this phenomenon, a probabilistic approach presents great potential for an adequate treatment of the problem. Finally, in order to find project configurations propitious to maintaining a given minimum level of safety during the entire useful structural life, optimization models under uncertainties can be used. Thus, the present work aims to present a formulation based on the BEM that makes possible the deterministic, probabilistic and optimization analysis of the initiation stage for unsteady state diffusion problems in concrete. The problem formulation and the implementation resolution scheme are described. Application examples are presented validating and showing the efficiency of the formulations adopted. The limitations of analytical solutions, the potentialities of the numerical solution and the great influence that the boundary conditions weigh on the phenomenon are highlighted.
202

Modelos numéricos aplicados à modelagem probabilística da degradação mecânica do concreto e corrosão de armaduras / Numerical models applied to the probabilistic modelling of the mechanical degradation of concrete and reinforcement corrosion

Coelho, Karolinne Oliveira 06 April 2017 (has links)
A corrosão de armaduras é uma das causas mais comuns de degradação mecânica em estruturas em concreto armado. Esse processo leva à redução da vida útil e, consequentemente, a prejuízos econômicos. Desse modo, o presente trabalho visa contribuir com a análise dos fenômenos associados à degradação mecânica do concreto armado sujeito a processos corrosivos devido à carbonatação e à ação de cloretos. Para tal finalidade, modelos analíticos baseados na segunda lei de Fick são usados para quantificar a difusão de CO2 e de íons cloreto no concreto, os quais permitem determinar o tempo de início da corrosão. A degradação mecânica de estruturas em concreto armado é considerada por meio de um modelo em dano concentrado que contempla perda da rigidez, redução da área de aço e da tensão de escoamento de armaduras devido ao processo corrosivo. A formulação de dano concentrado foi modificada de forma a incluir uma variável de estado de corrosão e uma lei de evolução da corrosão, baseada em equações semi-empíricas disponíveis na literatura. Essas equações determinam a redução no diâmetro das armaduras e a perda da capacidade resistente do aço. O problema da corrosão é formulado como um processo estocástico sendo resolvido por meio do método de simulação de Monte Carlo para dois exemplos: uma viga isostática e um pórtico plano com grau de hiperestaticidade igual a três. A formulação da equação de estado limite é baseada em um valor de dano aceitável. Curvas de probabilidade de início da corrosão e de probabilidade de falha da estrutura são obtidas ao longo de 50 anos. No caso da estrutura hiperestática, o caminho mais provável de falha, também chamado de caminho crítico, é determinado. Observa-se que o processo corrosivo provoca mudanças no caminho crítico, e portanto, deve ser considerado nas análises de reparo estrutural. Mapas de dano e de probabilidade de falha foram desenvolvidos para mostrar as mudanças no comportamento estrutural devido à corrosão. / The reinforcement\'s corrosion is one of the most common causes of mechanical degradation in reinforced concrete structures. This process leads to the reduction of the service life and, consequently, economic loss. Thereby, this study aims to contribute with the analysis of the phenomena associated to the mechanical degradation of reinforced concrete, due to the carbonation and the chloride ions. For this purpose, analytical models based on second Fick\'s law are used to quantify CO2 and chloride ions diffusion, which enables to determine the corrosion time initiation. The mechanical degradation of reinforced concrete structures is modeles by the lumped damage model which accounts for stiffness loss, reinforcement mass loss and yield stress reduction due to the corrosive process. The lumped damage formulation was modified to include the state corrosion variable and the corrosion evolution law based on semi-empirical equations available in the literature. These equations determine the reinforcement\'s diameter reduction and the loss of resistant capacity of the reinforcement\'s bar. The corrosion problem is formulated as a stochastic process and solved by the Monte Carlo simulation for two examples: an isostatic beam and a hyperstatic frame. The limit state functions are based on the acceptable damage value. Curves of probability of corrosion initiation and probability of failure are obtained over a range of 50 years. In the hyperstatic case, the most probable failure path, also named the critical path, is determined. It is observed that the corrosive process causes changes on the critical path and, therefore, it must be accounted on structural repair analysis. Damage and probability of failure maps were developed to show the changes on the structural behavior due to the corrosion.
203

Estudo dos parâmetros: teor de NaCl e acabamento superficial, na resistência à corrosão localizada e generalizada em tubos de cobre / Study of the parameters: NaCl concentration and surface finish on the pitting corrosion resistance of copper tubes

Jesus, Antonio Carlos Neto de 17 March 2008 (has links)
Tubos de cobre fabricados com o material ASTM C12200 (99,9%Cu-0,015-0,040%P) são utilizados mundialmente no transporte de água potável. A maior causa de vazamentos nestas tubulações é a corrosão por pite, que usualmente estão relacionadas com a qualidade da água. Estudos recentes mostraram que vazamentos em tubos de cobre usados para transporte de água de rede pública ocorreram em decorrência da corrosão por pite, o que se deu em virtude da presença do íon cloreto originado do tratamento para a desinfecção da água. Outro parâmetro que pode influenciar a corrosão por pite é a condição de acabamento interno dos tubos. Os óleos lubrificantes usados no processo de fabricação de tubos de cobre contêm carbono e este forma um filme deletério após o recozimento destes tubos. Este filme cria condições na superfície interna para a formação de pilhas de ação local. O objetivo deste trabalho é investigar se o teor de cloreto de sódio no meio aquoso, e o acabamento superficial da superfície interna de tubos de cobre utilizados comercialmente para transporte de água (ABNT/NBR-13206), têm influência na resistência à corrosão destes tubos. A resistência à corrosão foi investigada por meio de ensaios eletroquímicos em soluções naturalmente aeradas com várias concentrações de cloreto de sódio, a 25 oC. A superfície interna dos tubos foi observada, antes e após os ensaios eletroquímicos, por microscopia eletrônica de varredura (MEV). Os tipos de acabamentos superficiais estudados foram: desengraxamento, jateamento e acabamento do processo final de fabricação (sem tratamento). Foi também construído um circuito fechado para estudar o efeito do acabamento superficial na resistência à corrosão sob condições mais próximas das encontradas na prática. O efeito do tratamento de recozimento do tubo em atmosfera inerte, que causa a recristalização da microestrutura e eliminação dos resíduos de óleo lubrificante, também foi avaliado. Os resultados indicaram que o mecanismo de corrosão em soluções com teores de cloreto entre 0,06 mol L-1 e 0,12 mol L-1 correspondeu ao de ataque localizado, enquanto que para a concentração de 0,6 mol L-1 prevaleceu o ataque generalizado. Os resultados do estudo do efeito do acabamento superficial indicaram que os tratamentos que reduzem o teor de carbono na superfície são benéficos à resistência à corrosão, mas este não é o único fator que afeta a resistência à corrosão. Outras características superficiais resultantes do tratamento da superfície também devem ser consideradas. Por exemplo, embora o jateamento cause a diminuição do teor de carbono na superfície dos tubos, o aumento de rugosidade produzido por este acabamento pode resultar em uma menor resistência à corrosão. Os tratamentos superficiais que produziram superfície com maiores resistências à corrosão foram aqueles que também produziram superfícies com menores teores de carbono, a saber, desengraxe e recozimento. / Copper tubes manufactured with C12200 ASTM (99.9% Cu-0015-0040% P) are used worldwide for potable water transport. The largest number of leakages in these tubes is due to pitting, usually related to the water quality, associated to the presence of chloride ions originated from water disinfecting treatment. The literature on the effect of chloride on the corrosion of copper pipelines is controversial. The finishing of the copper tubes inner might also influence pitting corrosion. The lubricating oils used in the manufacture of copper tubes contain carbon and a deleterious film might form during annealing. The objective of this study is to investigate the effect of sodium chloride content and the inner surface finishing of copper tubes used for water transport (ABNT/NBR-13206) on their corrosion resistance. The study was carried out by electrochemical tests in naturally aerated sodium chloride solutions at various concentrations, at 25 °C. The tubes inner surface was observed previous to and after the electrochemical tests by scanning electron microscopy (SEM). The effects of the following surface finishing were investigated: degrease, sand blasting, annealing and the surface without treatment. A loop was built to simulate the operational conditions of the tubes. Results indicated that the corrosion mechanism in chloride solutions with concentrations between 0.06 mol L-1 and 0.12 mol L-1 was localized attack, whereas in the 0.6 mol L-1 solution, generalized attack was the predominant mechanism. The results the surface finishing investigation indicated that the treatments that leads to carbon content reduction are beneficial to corrosion resistance. However, other features must also be considered. For instance, although sand blasting reduces the carbon content on the tubes surface, the increase in roughness due to this treatment decreases the corrosion resistance. The surface treatments that resulted in increased corrosion resistance were those that also resulted in lower carbon levels at the surface, namely degreasing and annealing.
204

Estudo dos parâmetros: teor de NaCl e acabamento superficial, na resistência à corrosão localizada e generalizada em tubos de cobre / Study of the parameters: NaCl concentration and surface finish on the pitting corrosion resistance of copper tubes

Antonio Carlos Neto de Jesus 17 March 2008 (has links)
Tubos de cobre fabricados com o material ASTM C12200 (99,9%Cu-0,015-0,040%P) são utilizados mundialmente no transporte de água potável. A maior causa de vazamentos nestas tubulações é a corrosão por pite, que usualmente estão relacionadas com a qualidade da água. Estudos recentes mostraram que vazamentos em tubos de cobre usados para transporte de água de rede pública ocorreram em decorrência da corrosão por pite, o que se deu em virtude da presença do íon cloreto originado do tratamento para a desinfecção da água. Outro parâmetro que pode influenciar a corrosão por pite é a condição de acabamento interno dos tubos. Os óleos lubrificantes usados no processo de fabricação de tubos de cobre contêm carbono e este forma um filme deletério após o recozimento destes tubos. Este filme cria condições na superfície interna para a formação de pilhas de ação local. O objetivo deste trabalho é investigar se o teor de cloreto de sódio no meio aquoso, e o acabamento superficial da superfície interna de tubos de cobre utilizados comercialmente para transporte de água (ABNT/NBR-13206), têm influência na resistência à corrosão destes tubos. A resistência à corrosão foi investigada por meio de ensaios eletroquímicos em soluções naturalmente aeradas com várias concentrações de cloreto de sódio, a 25 oC. A superfície interna dos tubos foi observada, antes e após os ensaios eletroquímicos, por microscopia eletrônica de varredura (MEV). Os tipos de acabamentos superficiais estudados foram: desengraxamento, jateamento e acabamento do processo final de fabricação (sem tratamento). Foi também construído um circuito fechado para estudar o efeito do acabamento superficial na resistência à corrosão sob condições mais próximas das encontradas na prática. O efeito do tratamento de recozimento do tubo em atmosfera inerte, que causa a recristalização da microestrutura e eliminação dos resíduos de óleo lubrificante, também foi avaliado. Os resultados indicaram que o mecanismo de corrosão em soluções com teores de cloreto entre 0,06 mol L-1 e 0,12 mol L-1 correspondeu ao de ataque localizado, enquanto que para a concentração de 0,6 mol L-1 prevaleceu o ataque generalizado. Os resultados do estudo do efeito do acabamento superficial indicaram que os tratamentos que reduzem o teor de carbono na superfície são benéficos à resistência à corrosão, mas este não é o único fator que afeta a resistência à corrosão. Outras características superficiais resultantes do tratamento da superfície também devem ser consideradas. Por exemplo, embora o jateamento cause a diminuição do teor de carbono na superfície dos tubos, o aumento de rugosidade produzido por este acabamento pode resultar em uma menor resistência à corrosão. Os tratamentos superficiais que produziram superfície com maiores resistências à corrosão foram aqueles que também produziram superfícies com menores teores de carbono, a saber, desengraxe e recozimento. / Copper tubes manufactured with C12200 ASTM (99.9% Cu-0015-0040% P) are used worldwide for potable water transport. The largest number of leakages in these tubes is due to pitting, usually related to the water quality, associated to the presence of chloride ions originated from water disinfecting treatment. The literature on the effect of chloride on the corrosion of copper pipelines is controversial. The finishing of the copper tubes inner might also influence pitting corrosion. The lubricating oils used in the manufacture of copper tubes contain carbon and a deleterious film might form during annealing. The objective of this study is to investigate the effect of sodium chloride content and the inner surface finishing of copper tubes used for water transport (ABNT/NBR-13206) on their corrosion resistance. The study was carried out by electrochemical tests in naturally aerated sodium chloride solutions at various concentrations, at 25 °C. The tubes inner surface was observed previous to and after the electrochemical tests by scanning electron microscopy (SEM). The effects of the following surface finishing were investigated: degrease, sand blasting, annealing and the surface without treatment. A loop was built to simulate the operational conditions of the tubes. Results indicated that the corrosion mechanism in chloride solutions with concentrations between 0.06 mol L-1 and 0.12 mol L-1 was localized attack, whereas in the 0.6 mol L-1 solution, generalized attack was the predominant mechanism. The results the surface finishing investigation indicated that the treatments that leads to carbon content reduction are beneficial to corrosion resistance. However, other features must also be considered. For instance, although sand blasting reduces the carbon content on the tubes surface, the increase in roughness due to this treatment decreases the corrosion resistance. The surface treatments that resulted in increased corrosion resistance were those that also resulted in lower carbon levels at the surface, namely degreasing and annealing.
205

Development and Application of Chlorine Solid-State Nuclear Magnetic Resonance and Quantum Chemical Calculations to the Study of Organic and Inorganic Systems

Chapman, Rebecca 12 January 2012 (has links)
Chlorine solid-state nuclear magnetic resonance (SSNMR) is an ideal site specific probe of chloride-containing solids as SSNMR tensor properties are sensitive to the local chlorine environment. In this thesis, the development and use of chlorine SSNMR as a method to characterize a wide variety of chemical environments was explored. Ultrahigh field, and multi-field studies were essential to overcome the difficulties associated with the collection of chlorine SSNMR spectra. Benchmark chemical shift (CS) and electric field gradient (EFG) tensor data were collected for organic chloride systems, including several amino acid hydrochlorides. These experiments demonstrated the sensitivity of chlorine SSNMR to slight changes in chemical environment. Quantum chemical calculations were used to complement experimental data, with the gauge-including projector augmented wave DFT (GIPAW-DFT) method shown to yield better agreement than B3LYP or RHF methods. The GIPAW-DFT method was found to slightly, but systematically, overestimate the chlorine quadrupolar coupling constant and the CS tensor span. Other organic chlorides examined by chlorine SSMR included a known ion receptor, meso-octamethylcalix[4]pyrrole. This compound was found to have a very small quadrupole interaction (QI), but significant chemical shift anisotropy (CSA). GIPAW-DFT calculations were also utilized and, in combination with the experimental results, used to identify the solvate structure of the material analyzed by NMR. Chlorine SSNMR was further used to study different solvate structures and polymorphism. The technique was an effective means to distinguish different room temperature polymorphs of benzidine hydrochloride, despite the similarities of the chloride environments. In the case of magnesium chloride, chlorine SSNMR was sensitive to the level of hydration and through the use of GIPAW-DFT calculations, the identity of an unknown hydrate was determined. An analysis of several group thirteen chlorides demonstrated that chlorine SSNMR was also capable of characterizing the chlorine environment in cases where the QI is large, despite the resulting broad line widths. In these systems GIPAW-DFT calculations also yielded excellent agreement with experimental values. Throughout this research, chlorine SSNMR has been shown to be a useful and effective means to study both organic and inorganic chlorides, with computational methods proving to be an important complement to experimental data.
206

Development and Application of Chlorine Solid-State Nuclear Magnetic Resonance and Quantum Chemical Calculations to the Study of Organic and Inorganic Systems

Chapman, Rebecca 12 January 2012 (has links)
Chlorine solid-state nuclear magnetic resonance (SSNMR) is an ideal site specific probe of chloride-containing solids as SSNMR tensor properties are sensitive to the local chlorine environment. In this thesis, the development and use of chlorine SSNMR as a method to characterize a wide variety of chemical environments was explored. Ultrahigh field, and multi-field studies were essential to overcome the difficulties associated with the collection of chlorine SSNMR spectra. Benchmark chemical shift (CS) and electric field gradient (EFG) tensor data were collected for organic chloride systems, including several amino acid hydrochlorides. These experiments demonstrated the sensitivity of chlorine SSNMR to slight changes in chemical environment. Quantum chemical calculations were used to complement experimental data, with the gauge-including projector augmented wave DFT (GIPAW-DFT) method shown to yield better agreement than B3LYP or RHF methods. The GIPAW-DFT method was found to slightly, but systematically, overestimate the chlorine quadrupolar coupling constant and the CS tensor span. Other organic chlorides examined by chlorine SSMR included a known ion receptor, meso-octamethylcalix[4]pyrrole. This compound was found to have a very small quadrupole interaction (QI), but significant chemical shift anisotropy (CSA). GIPAW-DFT calculations were also utilized and, in combination with the experimental results, used to identify the solvate structure of the material analyzed by NMR. Chlorine SSNMR was further used to study different solvate structures and polymorphism. The technique was an effective means to distinguish different room temperature polymorphs of benzidine hydrochloride, despite the similarities of the chloride environments. In the case of magnesium chloride, chlorine SSNMR was sensitive to the level of hydration and through the use of GIPAW-DFT calculations, the identity of an unknown hydrate was determined. An analysis of several group thirteen chlorides demonstrated that chlorine SSNMR was also capable of characterizing the chlorine environment in cases where the QI is large, despite the resulting broad line widths. In these systems GIPAW-DFT calculations also yielded excellent agreement with experimental values. Throughout this research, chlorine SSNMR has been shown to be a useful and effective means to study both organic and inorganic chlorides, with computational methods proving to be an important complement to experimental data.
207

Development and Application of Chlorine Solid-State Nuclear Magnetic Resonance and Quantum Chemical Calculations to the Study of Organic and Inorganic Systems

Chapman, Rebecca 12 January 2012 (has links)
Chlorine solid-state nuclear magnetic resonance (SSNMR) is an ideal site specific probe of chloride-containing solids as SSNMR tensor properties are sensitive to the local chlorine environment. In this thesis, the development and use of chlorine SSNMR as a method to characterize a wide variety of chemical environments was explored. Ultrahigh field, and multi-field studies were essential to overcome the difficulties associated with the collection of chlorine SSNMR spectra. Benchmark chemical shift (CS) and electric field gradient (EFG) tensor data were collected for organic chloride systems, including several amino acid hydrochlorides. These experiments demonstrated the sensitivity of chlorine SSNMR to slight changes in chemical environment. Quantum chemical calculations were used to complement experimental data, with the gauge-including projector augmented wave DFT (GIPAW-DFT) method shown to yield better agreement than B3LYP or RHF methods. The GIPAW-DFT method was found to slightly, but systematically, overestimate the chlorine quadrupolar coupling constant and the CS tensor span. Other organic chlorides examined by chlorine SSMR included a known ion receptor, meso-octamethylcalix[4]pyrrole. This compound was found to have a very small quadrupole interaction (QI), but significant chemical shift anisotropy (CSA). GIPAW-DFT calculations were also utilized and, in combination with the experimental results, used to identify the solvate structure of the material analyzed by NMR. Chlorine SSNMR was further used to study different solvate structures and polymorphism. The technique was an effective means to distinguish different room temperature polymorphs of benzidine hydrochloride, despite the similarities of the chloride environments. In the case of magnesium chloride, chlorine SSNMR was sensitive to the level of hydration and through the use of GIPAW-DFT calculations, the identity of an unknown hydrate was determined. An analysis of several group thirteen chlorides demonstrated that chlorine SSNMR was also capable of characterizing the chlorine environment in cases where the QI is large, despite the resulting broad line widths. In these systems GIPAW-DFT calculations also yielded excellent agreement with experimental values. Throughout this research, chlorine SSNMR has been shown to be a useful and effective means to study both organic and inorganic chlorides, with computational methods proving to be an important complement to experimental data.
208

Solvation!

Ivana Adamovic January 2004 (has links)
19 Dec 2004. / Published through the Information Bridge: DOE Scientific and Technical Information. "IS-T 2009" Ivana Adamovic. 12/19/2004. Report is also available in paper and microfiche from NTIS.
209

Retração total e penetração de cloretos em concretos com cimento Portland branco e escória de alto forno / Total shrinkage and chloride penetration in concretes with white Portland cement and blast furnace slag

Dellinghausen, Luciano de Medeiros 25 June 2009 (has links)
Drying Shrinkage is a phenomenon that occurs in concrete, subjected or not to a load, due to water loss, once exposed to environment and allowed to dry. It is responsible for almost the entire total shrinkage strain in concrete. A concrete element with restrained shrinkage deformation may develop tensions that cause cracks, allowing the ingress of aggressive agents that may cause some damage to the reinforcement, reducing, consequently, its strength and durability. The most common aggressive agent into concrete is the chloride ion, which is considered the great responsible for the early reinforcement corrosion of concrete structures, affecting its stability and durability. Corrosion of reinforcement bars due to the ingress of salts from sea water into concrete is recognized to be the most influent factor in the destructive mechanisms for marine structures. The use of mineral admixtures such as blast furnace slag, the increase of curing duration and the water/binder ratio reduction are measures that may reduce the chloride ion penetration. The aim of this study was to investigate the influence of the cement replacement content by slag, as well as the duration of curing on drying shrinkage, chloride ion penetration and compressive strength of concretes made with high early age strength cement and white Portland cement. Water-binder ratios of 0.30, 0.42 and 0.55, curing duration of 3 and 7 days, besides the cement replacement contents of 0%, 50% and 70% were investigated. In order to analyze the influence of the alkali activation on the properties investigated, a concrete made with 50% white Portland cement replacement content by slag and activated by sodium sulfate (4% in mass of binder) was used. The compressive strength was evaluated in the ages of 3, 7, 28 and 91 days; the drying shrinkage in the ages of 7, 14, 21, 28, 35, 56, 91 and 182 days, and the chloride ion penetration (immersion test in chloride solution) in the ages of 7, 14, 28, 56 and 91 days. Before being immersed in the chloride solution, the specimens were subjected to a drying period of 91 days. The results obtained revealed that an increase in the slag content decreased the compressive strength and the drying shrinkage values, besides the smaller depths of chloride penetration with both cements used. Reducing the curing duration resulted greater drying shrinkage and depth of chloride penetration for both cements, independently the slag content. / A retração hidráulica é um fenômeno que ocorre no concreto, submetido ou não a carregamento, devido à perda de umidade, uma vez exposto ao meio ambiente e permitida sua secagem. Ela é responsável por praticamente toda a deformação total por retração no concreto. Um elemento de concreto com restrição de deformação por retração pode desenvolver tensões que levam à formação de fissuras, através das quais agentes agressivos podem penetrar e causar algum dano à armadura, reduzindo sua resistência e durabilidade. O agente agressivo mais comum é o íon cloreto, o qual é considerado como a maior causa de corrosão prematura das barras de armaduras das estruturas de concreto, afetando sua estabilidade e vida útil. A corrosão de armaduras devido ao ingresso de íons cloretos da água do mar no concreto é universalmente conhecida como o fator de maior influência nos mecanismos destrutivos de estruturas marinhas. A utilização de adições minerais como a escória de alto forno, o aumento no prazo de cura e a redução na relação água/aglomerante são medidas que podem diminuir a penetração desses íons no concreto. Este trabalho teve por objetivo investigar a influência do teor de escória e do período de cura na retração hidráulica, na penetração de íons cloretos e na resistência à compressão axial de concretos compostos de cimento Portland de alta resistência inicial e cimento Portland branco estrutural. Foram adotadas relações água/aglomerante de 0.30, 0.42 e 0.55, teores de escória, em substituição ao cimento Portland, de 0%, 50% e 70%, além de períodos de cura de 3 e 7 dias. Foi empregada uma mistura composta de 50% de escória em substituição ao cimento Portland branco, ativada quimicamente por sulfato de sódio (4% da massa de aglomerante) para analisar a influência do ativador nas propriedades investigadas. As idades avaliadas para o ensaio de resistência à compressão foram de 3, 7, 28 e 91 dias; para retração hidráulica idades de 7, 14, 21, 28, 35, 56, 91 e 182 dias e, para penetração de íons cloretos (imersão em solução salina) as idades de 7, 14, 28, 56 e 91 dias. Antes de serem imersos em solução salina os corpos-de-prova foram submetidos a um período de secagem de 91 dias. Dos resultados obtidos, constatou-se que o aumento do teor de escória resultou em decréscimo nos valores de resistência à compressão, de retração e de penetração de cloretos para os dois cimentos investigados. A diminuição no período de cura resultou em maiores valores de retração e de penetração de cloretos, tanto no concreto branco quanto no cinza, independentemente do teor de escória utilizado.
210

Disseminação de íons cloreto na orla marítima do bairro de Boa Viagem, Recife-PE / Dissemination of chloride íons in marine edge of Boa Viagem quarter, Recife-PE

Ronaldo Bezerra Pontes 30 March 2006 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Diante da exposição à névoa salina, as estruturas em concreto podem sofrer ataques por cloretos, provocando corrosão das armaduras. As peças com faces voltadas aos ventos dominantes estão mais suscetíveis, especialmente aquelas que possuem grande superfície em relação ao volume, como são os casos de pilares e vigas. Este trabalho tem como objetivo avaliar os níveis de agressividade marinha, na orla marítima do Bairro de Boa Viagem, Recife-PE, em função de sua distância em relação ao mar, medindo a taxa de deposição de cloretos, pelo método da vela úmida, tendo como apoio o monitoramento do ambiente. Os resultados indicam que os íons cloreto chegam à superfície das estruturas a distintos níveis de concentração, dependendo da distância em relação à sua fonte geradora, no caso, o mar. Conclui-se que a deposição de cloretos decresce, numa relação do tipo exponencial, à medida que há um aumento do distanciamento em relação ao mar, e que a agressividade é significativa até 400 m da orla marítima / Exposing concrete structures to the saline mist, they can suffer chlorides attacks and could cause reinforcement corrosion. The structures parts with faces directed to dominant winds are more susceptible, especially those with great surface in relation to the volume, such as pillars and beams. This work objective is to evaluate the level of marine aggressiveness, in marine edge of Boa Viagem quarter, Recife-PE, in function of the distance to the sea, measuring the value of chloride deposition, using the wet candle method, with the support of the environment management. The results indicate that chloride ions reach surface structure in different levels of concentration, depending on the distance from its origin, in this case, the sea. The conclusion is that chloride deposition decreases, in an exponential relation, when there is an increase of the distance to the sea, and that aggressiveness is significantly as far as 400 m from the marine edge

Page generated in 0.027 seconds