• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • 1
  • Tagged with
  • 70
  • 70
  • 28
  • 23
  • 22
  • 18
  • 18
  • 17
  • 15
  • 14
  • 13
  • 12
  • 12
  • 12
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Terras raras: obtenção de padrões espectroquímicos, estudo dos carbonatos e síntese dos peroxicarbonatos - uma nova série de compostos

QUEIROZ, CARLOS A. da S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:26Z (GMT). No. of bitstreams: 1 12439.pdf: 2272012 bytes, checksum: 7613b3ca85070891c495da134eac2872 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Quimica, Universidade de Sao Paulo - IQ/USP
22

Determinacao de iridio em baixas concentracoes(sub ng gsup-1) em materiais geologicos por ativacao neutronica

MORCELLI, CLAUDIA P.R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:49Z (GMT). No. of bitstreams: 1 06633.pdf: 3576512 bytes, checksum: 5fb55fd14239cf9ae62a4825e5902dc6 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
23

Validação dos métodos de análise por ativação do Laboratório de Análise por Ativação Neutrônica do IPEN - CNEN/SP visando à produção de materiais de referência certificados / Validation of the Neutron Activation Analysis methods of the Neutron Activation Laboratory at IPEN-CNEN/SP aiming the production of certified reference materials

PETRONI, ROBSON 23 July 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-07-23T11:19:49Z No. of bitstreams: 0 / Made available in DSpace on 2015-07-23T11:19:49Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
24

Preparo, caracterização e uso de um material de referência para ensaios de proficiência para determinação de metais em tecido de peixe in natura / Preparation, characterization and use of a reference material to proficiency testing for determination of metals in fish tissue in natura

SANTANA, LUCIANA VIEIRA de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:35Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:14Z (GMT). No. of bitstreams: 0 / Os ensaios de proficiências são amplamente utilizados para avaliar a capacidade analítica de laboratórios e também como parte dos processos de acreditação. Por esta razão, são importantes ferramentas para o controle dos resultados analíticos obtidos nos laboratórios que atuam diretamente com as empresas exportadoras de pescado. No Brasil não há provedores de ensaios de proficiência para metais potencialmente tóxicos em pescado. Neste trabalho serão descritos todos os passos utilizados para a produção de materiais de referência a serem utilizados em um estudo piloto de ensaios de proficiência para As, Cd, Pb e Hg em tecido de peixe in natura, seguindo as recomendações do Guia ISO 35. O esquema de preparação consistiu na seleção de indivíduos, limpeza, trituração, homogeneização e fortificação com As, Cd e Pb em dois níveis de concentração. A preparação resultou em 164 sachês de 10 g cada. A fim de avaliar o efeito da irradiação gama na conservação das amostras 52 sachês foram irradiados com uma fonte gamacell de cobalto 60 (60Co) (10,00 ± 1,05 KGy) e 52 não irradiadas, ambos selecionados aleatóriamente foram separados para os estudos de homogeneidade e estabilidade. O restante 60 sachês foram utilizados no ensaio de proficiência. Os resultados demonstraram que ambos os materiais foram homogêneos e apresentaram boa estabilidade (durante um período de 45 dias). No entanto, o material irradiado, apresentou uma melhor integridade foi um passo era crucial para assegurar a preservação da integridade, para a degradação biológica, quando armazenado em temperatura ambiente. Por esta razão, eles foram usados para o programa piloto de ensaios de proficiência. Dez laboratórios participaram do estudo piloto de ensaios de proficiência e os resultados foram avaliados por meio dos seguintes testes: z-score, a confiança elipse e erro normalizado. Este trabalho demonstra a capacidade do laboratório para a produção de materiais de referência, bem como para organizar e realizar testes de proficiência. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
25

Implantação do novo protocolo de dosimetria da AIEA no LCI/IPEN/CNEN

SIQUEIRA, PATRICIA M. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:44Z (GMT). No. of bitstreams: 0 / A fim de implementar o novo código de prática da Agência Internacional de Energia Atômica (AIEA) no Brasil, o Laboratório de Calibração de Instrumentos (LCI/IPEN) está realizando calibrações em termos de kerma no ar e em termos de dose absorvida na água, em feixes de 60Co. As razões ND,w/NK obtidas são comparadas com valores da literatura, obtendo-se concordância satisfatória. As diferenças entre os valores das razões CK (ND,w/NK) obtidas no presente trabalho e os valores da literatura são devidas a vários fatores. Estes fatores podem ser as variações entre as câmaras, que devem ser objeto de diferenças nas incertezas estimadas pelos PSDLs, e as diferenças nos padrões utilizados por cada Instituto de Metrologia Nacional (NMI) ou Laboratório de Dosimetria. No entanto, se forem conhecidas as razões entre cada NMI e o BIPM, para os padrões de kerma no ar e de dose absorvida na água, é possível a normalização das razões CK medidas para as razões equivalentes ao BIPM. Todos os resultados de razões CK obtidos foram convertidos para as razões equivalentes ao BIPM para facilitar a comparação. Neste trabalho é discutida a utilização da razão CK como parâmetro de controle de qualidade na verificação de resultados das calibrações rotineiras. Para avaliação dos procedimentos de calibração adotados no LCI, foram realizados testes de estabilidade a longo prazo com as câmaras de ionização padrões. Além disso, foi criado um banco de dados para armazenamento dos dados de calibração, com o objetivo de melhorar a qualidade do procedimento de calibração. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
26

Desenvolvimento de um sistema de referencia e de uma metodologia para calibracao de aplicadores oftalmicos utilizados em braquiterapia

OLIVEIRA, MERCIA L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:14Z (GMT). No. of bitstreams: 1 10308.pdf: 5951521 bytes, checksum: c3f464af4f9a5b567dacd34287e1566f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP / FAPESP:01/00231-5
27

Preparação e caracterização de um material de referência de peixe / Preparation and characterization of the fish reference material

ULRICH, JOAO C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:58Z (GMT). No. of bitstreams: 0 / Os materiais de referência certificados (MRCs) desempenham importante papel na obtenção de resultados de medições rastreáveis ao Sistema Internacional de Unidades (SI), por meio de uma cadeia contínua de comparações. Dessa forma, a demanda por novos materiais de referência certificados (MRC) aumenta a cada dia em todas as áreas do conhecimento. A disponibilidade de materiais de referência, principalmente no Brasil, ainda é incipiente, face a demanda que excede em muito a variedade disponível desses materiais. Entre as diversas áreas carentes de materiais de referência, destaca-se a área de alimentos pela importância desses produtos na balança comercial do país. A certificação de produtos alimentícios, destinados tanto para exportação como para o consumo interno, requer metodologias de análise que ofereçam resultados precisos e exatos a fim de assegurar a qualidade do produto. Este trabalho descreve a produção e certificação de um material de referência na matriz peixe em mercúrio e metilmercúrio. O estudo reúne desde a etapa de seleção do material, preparação, desenvolvimento dos estudos de homogeneidade e estabilidade e a caracterização. A certificação foi realizada por meio de medições utilizando duas técnicas analíticas, a Espectrofotometria de Absorção Atômica (AAS) com sistema de injeção em fluxo e geração de vapor frio (FIA-CV-AAS) e a Diluição Isotópica aplicada a Espectrometria de Massas (IDMS), sendo este um método primário. Neste trabalho as normas da série ISO 30 (ABNT 3034) e ISO Guide 35 foram utilizadas como base para a preparação e caracterização do material. Para o cálculo de incertezas foi utilizado o GUM e o guia Eurachem. Como resultado, foi produzido e certificado um lote do material em relação ao teor de mercúrio (Hg = 0,271±0,057 μg g-1) e metilmercúrio (MeHg = 0,245±0,038 μg g-1), além de valores informativos de chumbo e arsênio. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
28

Projeto de um laboratorio integrado de calibracao de instrumentos no IPEN / Project of an integrated calibration laboratory of instruments at IPEN

BARROS, GUSTAVO A.S.J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:20Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:32Z (GMT). No. of bitstreams: 0 / O Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares oferece serviços de calibração de detectores de radiação utilizados em radioproteção, radiodiagnóstico e radioterapia, para o IPEN e também para instalações externas, públicas e particulares. Uma parte de suas instalações estão localizadas no prédio principal, junto com outros laboratórios e salas de estudo, e uma outra parte num prédio isolado, semienterrado (Bunker). Para a otimização, a modernização e principalmente a segurança, os laboratórios situados no prédio principal precisam ser transferidos para um local isolado. Neste trabalho foi desenvolvido um projeto de um laboratório integrado, que será uma expansão do atual Laboratório de Calibração de Instrumentos do IPEN. Para isto, foram feitos levantamentos radiométricos no local escolhido e levantadas todas as necesidades da equipe quanto a espaço e disposição das salas. No projeto, os laboratórios com equipamentos de radiação X, e fontes radioativas alfa e beta ficaram isolados numa parte do prédio, e as blindagens das paredes foram determinadas, dependendo do uso de cada laboratório. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
29

Estudo comparativo entre metodos de calibracao de aplicadores clinicos de radiacao beta / Comparative study among calibration methods of clinical applicators of beta radiation

ANTONIO, PATRICIA de L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:14Z (GMT). No. of bitstreams: 0 / Os aplicadores clínicos de 90Sr+90Y são instrumentos utilizados em procedimentos de braquiterapia e devem ser calibrados periodicamente, de acordo com normas e recomendações internacionais. Neste trabalho, foram estudados quatro métodos de calibração de aplicadores dermatológicos e oftálmicos, comparando-se os resultados com os fornecidos pelos certificados de calibração dos fabricantes dos aplicadores. Os métodos envolveram o aplicador clínico padrão do Laboratório de Calibração de Instrumentos (LCI), calibrado pelo laboratório padrão primário americano do National Institute of Standards and Technology, como referência; um aplicador da Amersham, também pertencente ao LCI, como referência; uma mini-câmara de extrapolação desenvolvida no IPEN como padrão absoluto; e dosimetria termoluminescente. A mini-câmara de extrapolação e uma câmara de extrapolação comercial PTW foram estudadas com relação ao seu desempenho por meio de testes de controle de qualidade, como corrente de fuga, repetitividade e reprodutibilidade. A distribuição de dose em profundidade na água, estudo de grande importância na dosimetria de aplicadores clínicos, foi determinada utilizando-se a mini-câmara de extrapolação e dosímetros termoluminescentes. Os resultados obtidos foram considerados satisfatórios para os dois casos, quando comparados com os dados fornecidos pela norma IAEA (2002). Além disso, foi desenvolvido um sistema postal dosimétrico para a calibração de aplicadores clínicos por meio da técnica da termoluminescência, para ser enviado para clínicas e hospitais, sem a necessidade do transporte das fontes ao LCI do IPEN para calibração. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
30

Aplicacao da analise por ativacao com neutrons ao estudo da composicao quimica de materiais metalicos

MOREIRA, EDSON G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:32Z (GMT). No. of bitstreams: 1 08345.pdf: 6709285 bytes, checksum: 139e88373a9e4e322f099682e2297931 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.094 seconds