• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 7
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização geofísica de alvos rasos com aplicações no planejamento urbano e meio ambiente: estudo sobre o sítio controlado do IAG/USP / Geophysics characterization of shallow targets with applications in the urban planning and environmental: Study on the Shallow Geophysical Test Site of IAG/USP.

Borges, Welitom Rodrigues 29 June 2007 (has links)
A implantação do Sítio Controlado de Geofísica Rasa (SCGR), do Instituto de Astronomia, Geofísica e Ciências Atmosféricas (IAG), da Universidade de São Paulo (USP), é um marco na história da geofísica nacional. Trata-se do primeiro local de estudos controlados de geofísica rasa, instalado no Brasil. O SCGR está localizado próximo ao Instituto de Física, em frente ao IAG/USP, compreendendo uma área de 1500 m2 (50 m x 30 m). Nesta área, foram instalados diferentes alvos, com dimensões variadas e em diferentes profundidades, dispostos em sete linhas de 30 metros. Os alvos escolhidos tiveram como finalidade reproduzir uma pequena amostra dos principais objetos que são encontrados em ambiente urbano. O objetivo do estudo foi o de caracterizar os alvos instalados no SCGR, por meio da utilização de diferentes métodos geofísicos, com ênfase no método Ground Penetrating Radar (GPR), seguido dos métodos de eletrorresistividade e eletromagnético indutivo (EM-38). Esta caracterização consistiu em avaliar o desempenho e a confiabilidade dos métodos geofísicos, quando aplicados sobre alvos com propriedades físicas conhecidas. A coleta de dados foi realizada antes e depois da instalação do sítio controlado, permitindo, assim, a caracterização geofísica do meio (background) e dos alvos. Os resultados geofísicos foram apresentados na forma de perfis 2D e de cortes em profundidade em blocos volumétricos, Quase-3D. Os dados geofísicos do background evidenciam uma camada de aterro, com espessura de até 2,8 metros, repousando sobre sedimentos argilosos da planície de inundação do rio Pinheiros. O EM-38 possibilitou o mapeamento de todos os objetos metálicos enterrados até a profundidade máxima de 1,5 metro. A identificação de alguns alvos metálicos, enterrados na profundidade de 0,5 metro, também foi possível com os resultados de cargabilidade. Os dados de resistividade elétrica permitiram a identificação de um tubo metálico guia, enterrado no centro da área, a 0,5 metro de profundidade, e de alvos representativos de materiais geológicos. Os resultados de GPR permitiram o imageamento da maioria dos alvos implantados na área do SCGR, com melhor resolução aqueles que mostram maior contraste dielétrico. A pesquisa contribui para o refinamento dos métodos de campo aplicados aos problemas reais do cotidiano, principalmente, em estudos de geotecnia, planejamento urbano, arqueologia e meio ambiente. / The implantation of the Shallow Geophysical Test Site (SCGR) of the Astronomy, Geophysics and Atmospheric Sciences Institute (IAG), from University of Sao Paulo (USP), is a mark in national geophysical history. It is the first site Shallow geophysical study site installed in Brazil. This Test Site is located next to Physics Institute in front of IAG/USP, comprehending an area of 1500 m2 (50 m x 30 m). In this area, different targets were installed, with varied dimensions and different depths, buried in seven lines of 30 meters. Targets were chosen aiming at reproducing a small sample of main objects found in urban environment. The goal of the study was characterizing targets installed in SCGR by using different geophysical methods with emphasis in Ground Penetrating Radar (GPR), electric and inductive electromagnetic (EM-38) methods. This characterization consisted in evaluating the performance and reliability of geophysical methods, when applied in targets whose physical properties are well-known. Measurements were carried out before the targets installation in subsurface, in order to obtain data from land background or geologic horizons before disturbances. In a second stage, geophysical data were obtained after target installation. Geophysical results were shown in 2D profiles, and depth slices in volumetric blocks, Quasi-3D. Geophysical data from land background showed an earthwork layer, with thickness up to 2.8 meters, above loamy sediments of Pinheiros River. EM-38 enabled the mapping of all metallic targets buried until 1.5 meter of maxim depth. The identification of some metallic targets also buried in the depth of 0.5 meter was possible with chargeability results. Electric resistivity data allowed the identification of a metallic tube buried at the centre of the area, to 0.5 meter of depth, and of representative geological materials targets. GPR results identified of the majority of targets buried in SCGR with better resolution than those ones shown highest dielectric contrast. This research contributes for geophysical method refinement applied to everyday problems mostly in geotechnical, urban planning, archaeological and environmental studies.
2

Avaliação de aspectos geológicos e geotécnicos na implantação do aterro sanitário de São Carlos - SP, com o auxílio da geofísica / Evaluation of geological and geotechnical aspects in the implementation of the landfill of São Carlos-SP, with the help of geophysics

Schettini, Lucas 08 August 2016 (has links)
A caracterização geológica e geotécnica dos locais de implantação de aterros sanitários é fundamental, tanto para fornecer subsídios adequados ao projeto de instalação das células de deposição dos resíduos sólidos urbanos (RSU), quanto para que se conheçam as características da área antes de ser modificada pela obra. Neste sentido, o presente trabalho visou mostrar a contribuição que a geofísica, com o uso da técnica da eletrorresistividade e do potencial espontâneo, associado a informações de investigação geotécnica direta pode dar para o estabelecimento de um background da área de instalação do aterro sanitário da cidade de São Carlos-SP. Foram realizados 7 caminhamentos elétricos (CE) com o arranjo dipolo-dipolo com eletrodos espaçados de 10 metros e três sondagens elétricas verticais (SEV), utilizando o arranjo Schlumberger, com profundidade de investigação de até 100 metros. Para processamento dos modelos bidimensionais dos CE utilizou-se o programa RES2DINV, e enquanto que para as SEV foi utilizado o modelo unidimensional. A interpretação dos modelos geoelétricos foi aperfeiçoada pela confrontação com informações geológico-geotécnicas prévias da área, obtidas nos estudos de impacto ambiental (EIA/RIMA) e resultados de sondagens de simples reconhecimento (SPT), realizadas na fase de estudo para implantação do aterro sanitário. Com isso foi possível definir com clareza a profundidade do topo rochoso e das zonas de maior umidade nos CE e SEV. O conjunto de seções de CE foi georeferenciada com o auxílio de GPS de precisão, o que permitiu o tratamento espacial das informações e o estabelecimento dos mapas da superfície do topo rochoso, das zonas de fluxo de água subterrânea e da espessura dos materiais inconsolidados. O conjunto de informações obtido permitiu identificar locais possíveis para a instalação futura de poços de monitoramento, assim como os dados geoelétricos das várias camadas servirá como padrão para identificar eventuais contaminações do solo ou da água subterrânea no futuro. A identificação da presença do topo rochoso em pequena profundidade, em algumas áreas do aterro, permite o melhor planejamento das escavações para instalação das células de deposição do RSU. / The geological and geotechnical characterization of landfill implantation areas is crucial; even to provide appropriate subsidies of urban solid residues (USR) installation project of deposition cells and for knowing the characteristics of the area before being modified by the work. In this sense, the present work aimed to show the contribution that the geophysics, with the use of electrical resistivity technique and the spontaneous potential, associated with direct geotechnical investigation information can give to the establishment of a background of landfill installation area from São Carlos-SP city. Were performed 7 electrical imaging (EI) with the dipole-dipole array with electrodes spaced by 10 meters and three vertical electrical sounding (VES), using the Schlumberger array with depth research up to 100 meters. For processing of two-dimensional models of the EI was used the RES2DINV program and while for the vertical electrical sounding (VES)-was used one-dimensional model. Interpretation of geoelectric models was enhanced by the confrontation with geological and geotechnical information of prior area, obtained in the environmental impact assessment (EIA) and results of a simple reconnaissance probes, performed in the study phase for the landfill implementation. It was possible to clearly define the depth of the bedrock and the higher humidity areas in the EI and VES. The set of sections electrical Imaging (EI) was georeferenced with the aid of GPS accuracy that allowed the spatial treatment of Information and the setting maps of the bedrock surface, the groundwater flow zones and the thickness of the unconsolidated materials. The obtained set of information enabling identification of possible locations for the wells future monitoring installation, as well as the geoelectrical data from several layers will be use as a standard to identify possible contamination of the soil or groundwater in the future. The identification of bedrock presence in small depth, in some areas of landfill, allows better planning of excavation for installation of MSW deposition cells.
3

Caracterização geofísica de alvos rasos com aplicações no planejamento urbano e meio ambiente: estudo sobre o sítio controlado do IAG/USP / Geophysics characterization of shallow targets with applications in the urban planning and environmental: Study on the Shallow Geophysical Test Site of IAG/USP.

Welitom Rodrigues Borges 29 June 2007 (has links)
A implantação do Sítio Controlado de Geofísica Rasa (SCGR), do Instituto de Astronomia, Geofísica e Ciências Atmosféricas (IAG), da Universidade de São Paulo (USP), é um marco na história da geofísica nacional. Trata-se do primeiro local de estudos controlados de geofísica rasa, instalado no Brasil. O SCGR está localizado próximo ao Instituto de Física, em frente ao IAG/USP, compreendendo uma área de 1500 m2 (50 m x 30 m). Nesta área, foram instalados diferentes alvos, com dimensões variadas e em diferentes profundidades, dispostos em sete linhas de 30 metros. Os alvos escolhidos tiveram como finalidade reproduzir uma pequena amostra dos principais objetos que são encontrados em ambiente urbano. O objetivo do estudo foi o de caracterizar os alvos instalados no SCGR, por meio da utilização de diferentes métodos geofísicos, com ênfase no método Ground Penetrating Radar (GPR), seguido dos métodos de eletrorresistividade e eletromagnético indutivo (EM-38). Esta caracterização consistiu em avaliar o desempenho e a confiabilidade dos métodos geofísicos, quando aplicados sobre alvos com propriedades físicas conhecidas. A coleta de dados foi realizada antes e depois da instalação do sítio controlado, permitindo, assim, a caracterização geofísica do meio (background) e dos alvos. Os resultados geofísicos foram apresentados na forma de perfis 2D e de cortes em profundidade em blocos volumétricos, Quase-3D. Os dados geofísicos do background evidenciam uma camada de aterro, com espessura de até 2,8 metros, repousando sobre sedimentos argilosos da planície de inundação do rio Pinheiros. O EM-38 possibilitou o mapeamento de todos os objetos metálicos enterrados até a profundidade máxima de 1,5 metro. A identificação de alguns alvos metálicos, enterrados na profundidade de 0,5 metro, também foi possível com os resultados de cargabilidade. Os dados de resistividade elétrica permitiram a identificação de um tubo metálico guia, enterrado no centro da área, a 0,5 metro de profundidade, e de alvos representativos de materiais geológicos. Os resultados de GPR permitiram o imageamento da maioria dos alvos implantados na área do SCGR, com melhor resolução aqueles que mostram maior contraste dielétrico. A pesquisa contribui para o refinamento dos métodos de campo aplicados aos problemas reais do cotidiano, principalmente, em estudos de geotecnia, planejamento urbano, arqueologia e meio ambiente. / The implantation of the Shallow Geophysical Test Site (SCGR) of the Astronomy, Geophysics and Atmospheric Sciences Institute (IAG), from University of Sao Paulo (USP), is a mark in national geophysical history. It is the first site Shallow geophysical study site installed in Brazil. This Test Site is located next to Physics Institute in front of IAG/USP, comprehending an area of 1500 m2 (50 m x 30 m). In this area, different targets were installed, with varied dimensions and different depths, buried in seven lines of 30 meters. Targets were chosen aiming at reproducing a small sample of main objects found in urban environment. The goal of the study was characterizing targets installed in SCGR by using different geophysical methods with emphasis in Ground Penetrating Radar (GPR), electric and inductive electromagnetic (EM-38) methods. This characterization consisted in evaluating the performance and reliability of geophysical methods, when applied in targets whose physical properties are well-known. Measurements were carried out before the targets installation in subsurface, in order to obtain data from land background or geologic horizons before disturbances. In a second stage, geophysical data were obtained after target installation. Geophysical results were shown in 2D profiles, and depth slices in volumetric blocks, Quasi-3D. Geophysical data from land background showed an earthwork layer, with thickness up to 2.8 meters, above loamy sediments of Pinheiros River. EM-38 enabled the mapping of all metallic targets buried until 1.5 meter of maxim depth. The identification of some metallic targets also buried in the depth of 0.5 meter was possible with chargeability results. Electric resistivity data allowed the identification of a metallic tube buried at the centre of the area, to 0.5 meter of depth, and of representative geological materials targets. GPR results identified of the majority of targets buried in SCGR with better resolution than those ones shown highest dielectric contrast. This research contributes for geophysical method refinement applied to everyday problems mostly in geotechnical, urban planning, archaeological and environmental studies.
4

Avaliação de aspectos geológicos e geotécnicos na implantação do aterro sanitário de São Carlos - SP, com o auxílio da geofísica / Evaluation of geological and geotechnical aspects in the implementation of the landfill of São Carlos-SP, with the help of geophysics

Lucas Schettini 08 August 2016 (has links)
A caracterização geológica e geotécnica dos locais de implantação de aterros sanitários é fundamental, tanto para fornecer subsídios adequados ao projeto de instalação das células de deposição dos resíduos sólidos urbanos (RSU), quanto para que se conheçam as características da área antes de ser modificada pela obra. Neste sentido, o presente trabalho visou mostrar a contribuição que a geofísica, com o uso da técnica da eletrorresistividade e do potencial espontâneo, associado a informações de investigação geotécnica direta pode dar para o estabelecimento de um background da área de instalação do aterro sanitário da cidade de São Carlos-SP. Foram realizados 7 caminhamentos elétricos (CE) com o arranjo dipolo-dipolo com eletrodos espaçados de 10 metros e três sondagens elétricas verticais (SEV), utilizando o arranjo Schlumberger, com profundidade de investigação de até 100 metros. Para processamento dos modelos bidimensionais dos CE utilizou-se o programa RES2DINV, e enquanto que para as SEV foi utilizado o modelo unidimensional. A interpretação dos modelos geoelétricos foi aperfeiçoada pela confrontação com informações geológico-geotécnicas prévias da área, obtidas nos estudos de impacto ambiental (EIA/RIMA) e resultados de sondagens de simples reconhecimento (SPT), realizadas na fase de estudo para implantação do aterro sanitário. Com isso foi possível definir com clareza a profundidade do topo rochoso e das zonas de maior umidade nos CE e SEV. O conjunto de seções de CE foi georeferenciada com o auxílio de GPS de precisão, o que permitiu o tratamento espacial das informações e o estabelecimento dos mapas da superfície do topo rochoso, das zonas de fluxo de água subterrânea e da espessura dos materiais inconsolidados. O conjunto de informações obtido permitiu identificar locais possíveis para a instalação futura de poços de monitoramento, assim como os dados geoelétricos das várias camadas servirá como padrão para identificar eventuais contaminações do solo ou da água subterrânea no futuro. A identificação da presença do topo rochoso em pequena profundidade, em algumas áreas do aterro, permite o melhor planejamento das escavações para instalação das células de deposição do RSU. / The geological and geotechnical characterization of landfill implantation areas is crucial; even to provide appropriate subsidies of urban solid residues (USR) installation project of deposition cells and for knowing the characteristics of the area before being modified by the work. In this sense, the present work aimed to show the contribution that the geophysics, with the use of electrical resistivity technique and the spontaneous potential, associated with direct geotechnical investigation information can give to the establishment of a background of landfill installation area from São Carlos-SP city. Were performed 7 electrical imaging (EI) with the dipole-dipole array with electrodes spaced by 10 meters and three vertical electrical sounding (VES), using the Schlumberger array with depth research up to 100 meters. For processing of two-dimensional models of the EI was used the RES2DINV program and while for the vertical electrical sounding (VES)-was used one-dimensional model. Interpretation of geoelectric models was enhanced by the confrontation with geological and geotechnical information of prior area, obtained in the environmental impact assessment (EIA) and results of a simple reconnaissance probes, performed in the study phase for the landfill implementation. It was possible to clearly define the depth of the bedrock and the higher humidity areas in the EI and VES. The set of sections electrical Imaging (EI) was georeferenced with the aid of GPS accuracy that allowed the spatial treatment of Information and the setting maps of the bedrock surface, the groundwater flow zones and the thickness of the unconsolidated materials. The obtained set of information enabling identification of possible locations for the wells future monitoring installation, as well as the geoelectrical data from several layers will be use as a standard to identify possible contamination of the soil or groundwater in the future. The identification of bedrock presence in small depth, in some areas of landfill, allows better planning of excavation for installation of MSW deposition cells.
5

Metodologia para correlacionar a umidade, compactação e a condutividade elétrica aparente do solo / Methodology to correlate the humidity, compaction and soil apparent electrical conductivity

Silva Filho, Antônio Marcelino da 19 December 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-11-30T09:09:36Z No. of bitstreams: 2 Dissertação - Antônio Marcelino da Silva Filho - 2015.pdf: 2204549 bytes, checksum: 2f0941c7970eff84c86b64f4fd261cb6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-11-30T09:11:40Z (GMT) No. of bitstreams: 2 Dissertação - Antônio Marcelino da Silva Filho - 2015.pdf: 2204549 bytes, checksum: 2f0941c7970eff84c86b64f4fd261cb6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-11-30T09:11:40Z (GMT). No. of bitstreams: 2 Dissertação - Antônio Marcelino da Silva Filho - 2015.pdf: 2204549 bytes, checksum: 2f0941c7970eff84c86b64f4fd261cb6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-12-19 / This work presents the study of the relationship between soil apparent electrical resistivity ρa and the moisture content, clay content and soil compaction, for use of the ρa as a mapping tool of spatial soil variability. The values of apparent electrical resistivity are obtained by geoelectrical prospecting methods that detect the effects produced by the flow of electrical current in the soil. It is used the Wenner array and the technique of Lateral Profiling for data collection. It was held measures of ρa in different soil types, varying moisture content gradually while maintaining a constant compaction, and then varying the compaction and relating it to a constant humidity. To the study of spatial variability, it was chose two areas that would enable the change of moisture and compaction content, in order to verify the measurement capacity of ρa as methodology of identification of change in soil dynamics. The results obtained are presented and discussed. / Este trabalho apresenta o estudo das rela¸c˜oes entre a resistividade el´etrica aparente do solo ρa e o teor de umidade, teor de argila e compacta¸c˜ao do solo, para utiliza¸c˜ao de ρa como ferramenta de mapeamento da variabilidade espacial do solo. Os valores da resistividade el´etrica aparente s˜ao obtidos atrav´es de m´etodos de prospec¸c˜ao geoel´etricos que detectam os efeitos produzidos pelo fluxo de corrente el´etrica no solo. Utilizam-se o arranjo de Wenner e a t´ecnica do Caminhamento El´etrico para coleta dos dados. Realizaram-se medidas de ρa em diferentes tipos de solo, variando-se gradualmente o teor de umidade, mantendo-se constante a compacta¸c˜ao, e posteriormente variando a compacta¸c˜ao em fun¸c˜ao de valor constante de umidade. Para o estudo da variabilidade espacial, escolheram-se duas ´areas que possibilitassem a altera¸c˜ao dos teores de umidade e compacta¸c˜ao, a fim de verificar a capacidade da medi¸c˜ao de ρa como metodologia de identifica¸c˜ao de altera¸c˜oes na dinˆamica do solo. Os resultados obtidos s˜ao apresentados e discutidos.
6

Contribuição ao conhecimento do meio físico da região do lixão de São Carlos - SP, através de estudos geológicos, geofísicos, topográficos e químicos / Contribution to environment\'s knowledge of the Sao Carlos - SP waste dump area - by geological, geophysical, topographical and chemical studies

Álvares, Cyro Martins Bicudo 13 June 2000 (has links)
O lixão da cidade de São Carlos foi colocado, aproximadamente por dezessete anos, em uma boçoroca formada em região sedimentar, sobre os arenitos da Formação Botucatu, sem nenhuma espécie de controle prévio, quanto a possibilidade de contaminação do meio físico e, especialmente da água subterrânea. Dada essa possibilidade de contaminação do aqüífero profundo, uma série de estudos são feitos no local, desde a década de 80. Este trabalho vem somar-se aos diversos outros na tentativa de aprofundar o conhecimento das condições em que se encontra o meio físico na região do lixão. Fazendo parte de um projeto maior este trabalho procurou, utilizando as ciências de geologia, geofísica, topografia e química, dar novos elementos e interpretações a esse conhecimento. Geologicamente, detectamos e avaliamos a presença de camadas penetrativas, hidraulicamente menos condutivas, como areias siltosas e, muito provavelmente, arenito silicificado ou diabásio em profundidade, o que poderia fazer que a contaminação não atingisse o aqüífero profundo. Para isso utilizamos o mapeamento geológico e a geofísica em três de suas técnicas: caminhamento elétrico, sondagens elétricas verticais e perfilagem de poços. Quimicamente, avaliamos a contaminação das águas subterrâneas em relação ao sentido do fluxo. / For seventeen years, Sao Carlos\' solid wastes were placed in a gully formed in a sedimentary area, on the Botucatu Formation (friable sandstone and sands), without any form of control to prevent the contamination of the environment and, especially, of the ground water. Thanks to the possibility of contamination of the deep water source, a series of studies have been made in the area since the eighties. These studies were just another attempt, along with severaI others, to increase the knowledge of the environmental conditions surrounding the waste dump area. Being part of a greater project, different sciences were used such as geology, geophysics, topography and chemistry, in order to obtain new elements and a more acurate interpretation to the existing knowledge. Geologicaly, we detected a less hydraulicaly conductive silty sand layers and, probably, silicificated sandstone layers or diabase sill which could protect the deep water sources from being contaminated. Geologic mapping and geophysical techniques such as electric surveys and well logs were performed during the process. Chemically, we evaluated the ground water contamination in relation to the flow\'s direction.
7

Inversão Conjunta 2D de Dados de Caminhamento Elétrico e Caminhamento TDEM Aplicados a Estudos Hidrogeológicos em Taubaté/SP / 2D Joint Inversion of Electrical Resistivity Tomography (ERT) and Time Domain Electromagnetic (TDEM) Data Applied to a Hydrogeological Study of the Taubaté Basin, São Paulo State, Brazil.

Rodrigo Corrêa Rangel 23 March 2018 (has links)
Nesta Pesquisa foi empregada a metodologia de Inversão Conjunta 2D de dados de caminhamento elétrico (CE) e caminhamento eletromagnético no domínio do tempo (CTDEM) num estudo hidrogeológico da Bacia de Taubaté. A área de estudo localiza-se na cidade de Taubaté/SP, onde o Aquífero Taubaté é uma importante fonte alternativa de água frente à recente crise hídrica. O Grupo Taubaté é o principal pacote sedimentar da bacia, sendo formado principalmente por folhelhos, que formam aquicludes, e arenitos, que formam o aquífero. Foram identificados 40 poços de exploração de água subterrânea na cidade, cadastrados no banco de dados do SIAGAS-CPRM, os quais forneceram informações importantes para a interpretação dos resultados. O objetivo principal da pesquisa é caracterizar a estratigrafia geoelétrica da subsuperfície para localizar o contato entre os sedimentos Quaternários e Terciários e mapear o aquífero. Os dados de CE permitem o reconhecimento das camadas mais rasas, da ordem de dezenas de metros, e os dados de CTDEM investigam as camadas mais profundas, numa ordem de centenas de metros, portanto, fornecem informações complementares. Os resultados das inversões conjuntas de CE/CTDEM permitiram mapear as camadas sedimentares mais rasas resistivas até aproximadamente 30 m de profundidade, uma camada sedimentar condutiva intermediária entre 30 m e 50 m de profundidade, e uma camada condutiva referente ao Grupo Taubaté entre 50 m e 300 m de profundidade. O topo do embasamento da bacia foi inferido em ~300 m de profundidade com base nas informações de poços e de geologia da bacia, por outro lado, também é possível que essa interface represente uma variação faciológica do Grupo Taubaté, portanto, mais estudos são necessários. / In this research, a 2D Joint Inversion of electrical resistivity tomography (ERT) and time domain electromagnetic (TDEM) data was applied to a hydrogeological study of the Taubaté basin. The study area is in Taubaté city, São Paulo State, Brazil, where the Taubaté aquifer is an important alternative water source due to the recent water crisis. The Taubaté Group is the main sedimentary package of the basin, which is formed mainly by shales, that form aquicludes, and sandstones that form the aquifer. 40 groundwater exploration wells were identified in the city, registered in SIAGAS-CPRM database, which provided important information for the results interpretation. The main objective of this research is to characterize the geoelectrical stratigraphy of the subsurface to locate the contact between the Quaternary and Tertiary sediments and to map the aquifer. The ERT is used for shallow investigations (tens of meters) and the TDEM can reach a great investigation depth (hundreds of meters), therefore, they provide complementary information. The 2D ERT/TDEM joint inversion results permitted to map the shallower resistive layers down to 30 m depth, an intermediate conductive layer between 30 m and 50 m depth, and the Taubate Group between 50 m and 300 m depth, which is very conductive. The top of the basement was inferred at ~300 m depth based on the well information and the basin geology, on the other hand, it is also possible that this interface represents a faciological variation of the Taubaté Group, therefore, more studies are needed.
8

Inversão Conjunta 2D de Dados de Caminhamento Elétrico e Caminhamento TDEM Aplicados a Estudos Hidrogeológicos em Taubaté/SP / 2D Joint Inversion of Electrical Resistivity Tomography (ERT) and Time Domain Electromagnetic (TDEM) Data Applied to a Hydrogeological Study of the Taubaté Basin, São Paulo State, Brazil.

Rangel, Rodrigo Corrêa 23 March 2018 (has links)
Nesta Pesquisa foi empregada a metodologia de Inversão Conjunta 2D de dados de caminhamento elétrico (CE) e caminhamento eletromagnético no domínio do tempo (CTDEM) num estudo hidrogeológico da Bacia de Taubaté. A área de estudo localiza-se na cidade de Taubaté/SP, onde o Aquífero Taubaté é uma importante fonte alternativa de água frente à recente crise hídrica. O Grupo Taubaté é o principal pacote sedimentar da bacia, sendo formado principalmente por folhelhos, que formam aquicludes, e arenitos, que formam o aquífero. Foram identificados 40 poços de exploração de água subterrânea na cidade, cadastrados no banco de dados do SIAGAS-CPRM, os quais forneceram informações importantes para a interpretação dos resultados. O objetivo principal da pesquisa é caracterizar a estratigrafia geoelétrica da subsuperfície para localizar o contato entre os sedimentos Quaternários e Terciários e mapear o aquífero. Os dados de CE permitem o reconhecimento das camadas mais rasas, da ordem de dezenas de metros, e os dados de CTDEM investigam as camadas mais profundas, numa ordem de centenas de metros, portanto, fornecem informações complementares. Os resultados das inversões conjuntas de CE/CTDEM permitiram mapear as camadas sedimentares mais rasas resistivas até aproximadamente 30 m de profundidade, uma camada sedimentar condutiva intermediária entre 30 m e 50 m de profundidade, e uma camada condutiva referente ao Grupo Taubaté entre 50 m e 300 m de profundidade. O topo do embasamento da bacia foi inferido em ~300 m de profundidade com base nas informações de poços e de geologia da bacia, por outro lado, também é possível que essa interface represente uma variação faciológica do Grupo Taubaté, portanto, mais estudos são necessários. / In this research, a 2D Joint Inversion of electrical resistivity tomography (ERT) and time domain electromagnetic (TDEM) data was applied to a hydrogeological study of the Taubaté basin. The study area is in Taubaté city, São Paulo State, Brazil, where the Taubaté aquifer is an important alternative water source due to the recent water crisis. The Taubaté Group is the main sedimentary package of the basin, which is formed mainly by shales, that form aquicludes, and sandstones that form the aquifer. 40 groundwater exploration wells were identified in the city, registered in SIAGAS-CPRM database, which provided important information for the results interpretation. The main objective of this research is to characterize the geoelectrical stratigraphy of the subsurface to locate the contact between the Quaternary and Tertiary sediments and to map the aquifer. The ERT is used for shallow investigations (tens of meters) and the TDEM can reach a great investigation depth (hundreds of meters), therefore, they provide complementary information. The 2D ERT/TDEM joint inversion results permitted to map the shallower resistive layers down to 30 m depth, an intermediate conductive layer between 30 m and 50 m depth, and the Taubate Group between 50 m and 300 m depth, which is very conductive. The top of the basement was inferred at ~300 m depth based on the well information and the basin geology, on the other hand, it is also possible that this interface represents a faciological variation of the Taubaté Group, therefore, more studies are needed.
9

Contribuição ao conhecimento do meio físico da região do lixão de São Carlos - SP, através de estudos geológicos, geofísicos, topográficos e químicos / Contribution to environment\'s knowledge of the Sao Carlos - SP waste dump area - by geological, geophysical, topographical and chemical studies

Cyro Martins Bicudo Álvares 13 June 2000 (has links)
O lixão da cidade de São Carlos foi colocado, aproximadamente por dezessete anos, em uma boçoroca formada em região sedimentar, sobre os arenitos da Formação Botucatu, sem nenhuma espécie de controle prévio, quanto a possibilidade de contaminação do meio físico e, especialmente da água subterrânea. Dada essa possibilidade de contaminação do aqüífero profundo, uma série de estudos são feitos no local, desde a década de 80. Este trabalho vem somar-se aos diversos outros na tentativa de aprofundar o conhecimento das condições em que se encontra o meio físico na região do lixão. Fazendo parte de um projeto maior este trabalho procurou, utilizando as ciências de geologia, geofísica, topografia e química, dar novos elementos e interpretações a esse conhecimento. Geologicamente, detectamos e avaliamos a presença de camadas penetrativas, hidraulicamente menos condutivas, como areias siltosas e, muito provavelmente, arenito silicificado ou diabásio em profundidade, o que poderia fazer que a contaminação não atingisse o aqüífero profundo. Para isso utilizamos o mapeamento geológico e a geofísica em três de suas técnicas: caminhamento elétrico, sondagens elétricas verticais e perfilagem de poços. Quimicamente, avaliamos a contaminação das águas subterrâneas em relação ao sentido do fluxo. / For seventeen years, Sao Carlos\' solid wastes were placed in a gully formed in a sedimentary area, on the Botucatu Formation (friable sandstone and sands), without any form of control to prevent the contamination of the environment and, especially, of the ground water. Thanks to the possibility of contamination of the deep water source, a series of studies have been made in the area since the eighties. These studies were just another attempt, along with severaI others, to increase the knowledge of the environmental conditions surrounding the waste dump area. Being part of a greater project, different sciences were used such as geology, geophysics, topography and chemistry, in order to obtain new elements and a more acurate interpretation to the existing knowledge. Geologicaly, we detected a less hydraulicaly conductive silty sand layers and, probably, silicificated sandstone layers or diabase sill which could protect the deep water sources from being contaminated. Geologic mapping and geophysical techniques such as electric surveys and well logs were performed during the process. Chemically, we evaluated the ground water contamination in relation to the flow\'s direction.

Page generated in 0.0944 seconds