• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 4
  • 1
  • 1
  • Tagged with
  • 17
  • 10
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

REGULATION OF dsRNA-INDUCED TRANSCRIPTION BY NFêB AND IRF-3 THROUGH TLR3 AND RIG-I

Elco, Christopher 25 June 2007 (has links)
No description available.
2

Inversão conjunta 1D de dados de SEV e TDEM: aplicações em hidrogeologia / VES and TEM Soundings Joint Inversion: Applications in Hydrogeology

Cassiano Antonio Bortolozo 25 March 2011 (has links)
As sondagens elétricas verticais (SEV) e as sondagens eletromagnéticas no domínio do tempo (TDEM) são muito usadas em estudos ambientais, hidrogeológicos e em exploração mineral. A interpretação desses dados feita individualmente com modelos unidimensionais normalmente acarreta em resultados ambíguos. Isso acontece devido ao fato de que cada metodologia enxerga a subsuperfície de uma forma diferente. No caso da SEV as estruturas resistivas são bem detectadas, já no caso da sondagem TDEM as estruturas condutivas é que são detectadas com melhor precisão. Outra diferença é a capacidade da SEV conseguir identificar melhor as estruturas rasas, por outro lado, as sondagens TDEM permitem investigar as estruturas mais profundas. Nesta pesquisa foram exploradas as potencialidades das SEVs e das sondagens TDEM, visando obter uma interpretação dos dados mais consistentes. Neste sentido foi desenvolvido um programa em Matlab para a inversão conjunta 1D de dados de SEV e TDEM, na qual explora \"o melhor\" de ambos os métodos. O algoritmo desenvolvido foi testado inicialmente com dados sintéticos e posteriormente foi empregado em dados reais adquiridos na bacia sedimentar do Paraná, na região de Bebedouro no Estado de São Paulo. O resultado final da inversão conjunta de dados de SEV/TDEM permitiu obter um modelo geoelétrico que mais se assemelha às condições geológicas reais, e cujas ambigüidades, que são inerentes ao processo de interpretação, foram minimizadas. Os resultados tanto com dados sintéticos quanto com dados reais foram são bastante promissores, mostram uma melhor recuperação dos meios modelados e um grande potencial de aplicações em estudos geocientíficos, em particular em estudos hidrogeológicos. / Electrical (DC) and transient electromagnetic (TEM) soundings have been used in a great number of environmental, hydrological and mining exploration studies. The data interpretation usually is done individually by 1D models resulting in ambiguous results. This fact can be explained by how the two different methodologies observe the medium below the surface. The vertical electrical sounding (VES) is good at marking very resistive structures, while the transient electromagnetic sounding (TEM) is very sensitive to map conductive structures. Another difference is that the VES detects better shallow structures, while the TEM soundings can reach deeper ones. In this research we explore the potentials of the both VES and TEM soundings, in order to obtain a more consistent interpretation of the data. In this way, a Matlab program for the joint inversion for DC and TEM soundings was developed aiming explore the best of the both methods. Initially, the algorithm was tested with synthetic data and after were used real data from Paraná Sedimentary Basin in Bebedouro region, São Paulo State. The geoelectrical model obtained from joint inversion of DC and TEM data are more similar to the real geological condition and the ambiguities were minimized. The results with synthetic and real data shows that the joint inversion of DC/TEM is better for recovering the simulated models and shows a great potential in geological studies, particularly in hidrogeological studies.
3

Inversão conjunta 1D de dados de SEV e TDEM: aplicações em hidrogeologia / VES and TEM Soundings Joint Inversion: Applications in Hydrogeology

Bortolozo, Cassiano Antonio 25 March 2011 (has links)
As sondagens elétricas verticais (SEV) e as sondagens eletromagnéticas no domínio do tempo (TDEM) são muito usadas em estudos ambientais, hidrogeológicos e em exploração mineral. A interpretação desses dados feita individualmente com modelos unidimensionais normalmente acarreta em resultados ambíguos. Isso acontece devido ao fato de que cada metodologia enxerga a subsuperfície de uma forma diferente. No caso da SEV as estruturas resistivas são bem detectadas, já no caso da sondagem TDEM as estruturas condutivas é que são detectadas com melhor precisão. Outra diferença é a capacidade da SEV conseguir identificar melhor as estruturas rasas, por outro lado, as sondagens TDEM permitem investigar as estruturas mais profundas. Nesta pesquisa foram exploradas as potencialidades das SEVs e das sondagens TDEM, visando obter uma interpretação dos dados mais consistentes. Neste sentido foi desenvolvido um programa em Matlab para a inversão conjunta 1D de dados de SEV e TDEM, na qual explora \"o melhor\" de ambos os métodos. O algoritmo desenvolvido foi testado inicialmente com dados sintéticos e posteriormente foi empregado em dados reais adquiridos na bacia sedimentar do Paraná, na região de Bebedouro no Estado de São Paulo. O resultado final da inversão conjunta de dados de SEV/TDEM permitiu obter um modelo geoelétrico que mais se assemelha às condições geológicas reais, e cujas ambigüidades, que são inerentes ao processo de interpretação, foram minimizadas. Os resultados tanto com dados sintéticos quanto com dados reais foram são bastante promissores, mostram uma melhor recuperação dos meios modelados e um grande potencial de aplicações em estudos geocientíficos, em particular em estudos hidrogeológicos. / Electrical (DC) and transient electromagnetic (TEM) soundings have been used in a great number of environmental, hydrological and mining exploration studies. The data interpretation usually is done individually by 1D models resulting in ambiguous results. This fact can be explained by how the two different methodologies observe the medium below the surface. The vertical electrical sounding (VES) is good at marking very resistive structures, while the transient electromagnetic sounding (TEM) is very sensitive to map conductive structures. Another difference is that the VES detects better shallow structures, while the TEM soundings can reach deeper ones. In this research we explore the potentials of the both VES and TEM soundings, in order to obtain a more consistent interpretation of the data. In this way, a Matlab program for the joint inversion for DC and TEM soundings was developed aiming explore the best of the both methods. Initially, the algorithm was tested with synthetic data and after were used real data from Paraná Sedimentary Basin in Bebedouro region, São Paulo State. The geoelectrical model obtained from joint inversion of DC and TEM data are more similar to the real geological condition and the ambiguities were minimized. The results with synthetic and real data shows that the joint inversion of DC/TEM is better for recovering the simulated models and shows a great potential in geological studies, particularly in hidrogeological studies.
4

Étude climatologique, hydrogéologique et géophysique du Sahel Côtier des Doukkala (Maroc). Apport de l'analyse statistique et de l'inversion des données géoélectriques à l'étude du biseau salé de la lagune de Sidi Moussa

Oulaaross, Zhor 16 December 2009 (has links)
Ce travail concerne l’étude de la salinisation des eaux souterraines de la région côtière du Sahel- Doukkala. Afin de compléter la compréhension du comportement global de ce système aquifère, une approche pluridisciplinaire a été choisie. Dans un premier temps, une étude statistique des paramètres climatiques de la région a montré une hausse significative de la température et des fluctuations des précipitations annuelles dans la région du Sahel-Doukkala au cours des dernières années. L’étude statistique des sondages électriques verticaux réalisés en 1992 dans la région du Sahel Doukkala (analyse en composantes principales et classification hiérarchique ascendante), nous a permis de bien mettre en évidence la cartographie géoélectrique de la région d’étude (la distribution spatiale des différentes résistivités apparentes de ces sondages électriques verticaux) par ailleurs elle a permis de mettre en évidence une évolution des valeurs de résistivités apparentes par rapport à l’éloignement de ces sondages électriques à la mer. A l’issue de cette étude on a proposé d’inverser des données de sondages électriques de la ligne W18 au moyen d’une méthode d’optimisation fondée sur des algorithmes globaux tels que les essaims particulaires (PSO) ; ceci a permis d’estimer, le long d’un profil représentatif perpendiculaire à la côte, la position du biseau d’eau salée. Cette méthode d’optimisation permet d'avoir une distribution statistique des paramètres des modèles électriques (distributions des épaisseurs et des résistivités réelles des terrains) conditionnellement aux données des SEV. L’analyse des paramètres physico-chimiques mesurés et enregistrés dans la région du Sahel- Doukkala, a permis de caractériser la salinité des eaux souterraines et, une description détaillée du fonctionnement de l’aquifère côtier est proposée à partir de la comparaison de l’évolution de la conductivité, de la température et de la hauteur de l’eau par rapport à la marée dans quelque puits ; ces paramètres ont été enregistrés dans un puits localisé à proximité de la ligne 18W (domaine particulier sur lequel l’étude a été concentrée). En conclusion, ce travail apporte un point de vue nouveau sur la salinisation des eaux souterraines de la région du Sahel-Doukkala et a permis de proposer un modèle d’étude qui aide à la caractérisation de la salinité des eaux dans un aquifère côtier. / Abstract
5

Caracterização de áreas favoráveis à extração de blocos graníticos de grade porte com o uso da eletrorresistividade, Cabo de Santo Agostinho, PE / not available

Silva, Diego Daniel 24 October 2014 (has links)
Os métodos geoelétricos, principalmente a eletrorresistividade, estão sendo cada vez mais requisitados na área da mineração, indicando espessura de capeamento de solo, zonas fraturadas e heterogeneidades do material, viabilizando economicamente, ou não, um projeto minerário. Este trabalho, realizado no município do Cabo de Santo Agostinho -PE, apresenta e discute resultados de aplicações do método geofísico, da eletrorresistividade, como instrumento de auxílio na abertura de uma nova frente de lavra para extração de blocos graníticos de grande porte. Foi investigada a espessura do capeamento de solo, bem como as principais zonas locais de falhas e fraturas. Para isso foram realizadas 32 SEVs (03 SEVs por perfil, à exceção da Linha 11, com 02) com arranjo Schlumberger de AB/2 máximo de 60metros, e 11 caminhamentos elétricos com arranjo dipolo-dipolo de AB=MN=20 metros,com aproximadamente 1000m de extensão cada perfil. As SEVs foram dispostas nas linhas de modo a cobrir adequadamente a área do terreno, possibilitando a confecção de um mapa de contorno da profundidade do topo rochoso e a caracterização do perfil de alteração pedológico. Os caminhamentos elétricos foram dispostos paralelamente entre si e espaçados de 60 metros, podendo ser observadas as possíveis configurações do topo rochoso, como rocha não fraturada e zonas fraturadas. A partir dos dados dos caminhamentos elétricos foram elaboradas simulações 3D de resistividade e para a estimativa de volume de rocha não fraturada na área de estudo (com base nas resistividades mais elevadas).Os resultados obtidos mostraram a eficiência da eletrorresistividade na determinação do topo da rocha sã e detecção das zonas fraturadas no maciço granítico. / The geoeletric methods, especially electroresistivity, are being progressively more required on mining, for identifying soil thickness, fractured zones and geological heterogeneities, to check economical viability of mining projects. This work, held in Cabo de Santo Agostinho-PE city, presents and discusses geophysics application results of electroresistivity as a tool for helping the opening of a new granitic blocks exploitation front. The soil thickness was investigated, as well as the main local fault zones and fractures. A total of 32 VESs (03 VESs per section, exception made to line 11, with 02 VESs) using Schlumberger array with AB/2 maximum of 60 m, and 11 geoelectrical profilings using dipole-dipole array (AB=MN=20 m), with section lengths close to 1000 m. The VESs lines were organized in order to cover the studied area properly, allowing mapping the top of the rock massif and characterizing the soil profile. The geoelectrical profilings were disposed parallel with 60 m gap among each other, enabling the observation of the massif top configurations, such as fractured and non fractured zones. 3D resistivity simulations were performed using the geoelectrical profilings data in order to estimate the total volume of non fractured rock in the studied area (based on the highest resistivities). The obtained data showed the efficiency of electroresistivity for fractured zones detection and for mapping the top of the fresh rock massif.
6

Aplicação do método da eletrorresistividade na investigação e mapeamento da contaminação por cemitérios: o exemplo do cemitério da Vila Rezende, Piracicaba/SP

Silva, Robson Willians da Costa [UNESP] 10 April 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-04-10Bitstream added on 2014-06-13T21:00:57Z : No. of bitstreams: 1 silva_rwc_me_rcla.pdf: 3105248 bytes, checksum: 06caa8b8af7e5537292829c720639348 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho investigou e mapeou a contaminação por necrochorume da água subterrânea no aqüífero freático do cemitério de Vila Rezende, situado na zona norte do município de Piracicaba – São Paulo, Brasil. Para tanto, foi aplicado o método da eletrorresistividade, por meio das técnicas de sondagem elétrica vertical (SEV) e imageameanto elétrico (2D), arranjos schlumberger e dipolo-dipolo respectivamente, sendo a primeira com objetivo de estudar a distribuição do parâmetro resistividade elétrica verticalmente (1D) e a outra verticalmente e horizontalmente (2D e 3D). Os resultados da SEV indicam uma profundidade do nível freático entre 3,1 e 5,1 m na época de estiagem, com dois sentidos de fluxo subterrâneo, sendo um sentido a SW e o outro a SE. A subsuperfície do cemitério apresenta uma camada pouco espessa de aterro com sedimentos de textura arenosa, predominando logo abaixo sedimentos argilosos da Formação Corumbataí e diabásio das Intrusivas Básicas respectivamente. O cemitério apresenta condições fisico-químicas dos materiais em subsuperfície desfavoráveis para percolação do necrochorume, mas facilita o fenômeno de saponificação dos cadáveres. Os resultados obtidos das linhas de imageamento elétrico (2D) indicam duas prováveis plumas de contaminante em zona não-saturada, uma na direção SW e outra a SE, ambas seguindo a direção do fluxo subterrâneo. Mas em zona saturada predomina uma pluma a SE sob as quadras Q – 08, 04 e 01, e também fora dos limites do cemitério. As áreas com baixa resistividade (anomalia condutiva), apresentadas nas seções geoelétricas e nos mapas de resistividade elétrica, demonstram que a contaminação tem ligação com a profundidade do nível freático e com o tempo de sepultamento. Por meio dos resultados obtidos, como localização e expansão das prováveis plumas, foram locados seis poços de monitoramento. / This work investigated and mapped the contamination for necrochorume of the groundwater in the freatic aquifer of Vila Rezende's cemetery, located in the north area from Piracicaba - São Paulo, Brazil. For that, electrical resistivity method was applied using vertical electric sounding (VES) and 2D electrical imaging techniques, schlumberger and dipole-dipole arrays respectively, being the first with the objective to investigate the electric resistivity vertically (1D) and the other vertically and horizontally (2D and 3D). The results of VES indicate a depth of water table among 3,1 and 5,1 m in drought, with two flow directions, being a the SW and another the SE. Cemetery underground presents a fine layer of embankment with sediments of sandy texture, prevailing soon lowers clayey sediments of the Corumbataí Formation and diabase of the Basic Intrusive respectively. The cemetery presents physicalchemistry geological conditions unfavorable for percolation of the necrochorume, but facilitates the phenomenon of human corpse saponification. The obtained results of the lines of electrical imaging (2D) indicate two probable contamination plume in unsaturated zone, a in SW and another to SE direction, both following the groundwater flow. But in saturated zone prevails a plume at SE under the blocks Q - 08, 04 and 01, and also out of the cemetery of the limits. The areas with low resistivity (conductive anomaly), presented in the geoelectrical sections and in the electrical resistivity maps, demonstrate that the contamination has connection with the depth of the water table and time of burial. Through the obtained results, as location and expansion of the probable plumes, were suggested six monitoring wells. The applied methods in this work demonstrated as an important indirect instrument for evaluation of the environmental quality in cemeteries.
7

Caracterização de áreas favoráveis à extração de blocos graníticos de grade porte com o uso da eletrorresistividade, Cabo de Santo Agostinho, PE / not available

Diego Daniel Silva 24 October 2014 (has links)
Os métodos geoelétricos, principalmente a eletrorresistividade, estão sendo cada vez mais requisitados na área da mineração, indicando espessura de capeamento de solo, zonas fraturadas e heterogeneidades do material, viabilizando economicamente, ou não, um projeto minerário. Este trabalho, realizado no município do Cabo de Santo Agostinho -PE, apresenta e discute resultados de aplicações do método geofísico, da eletrorresistividade, como instrumento de auxílio na abertura de uma nova frente de lavra para extração de blocos graníticos de grande porte. Foi investigada a espessura do capeamento de solo, bem como as principais zonas locais de falhas e fraturas. Para isso foram realizadas 32 SEVs (03 SEVs por perfil, à exceção da Linha 11, com 02) com arranjo Schlumberger de AB/2 máximo de 60metros, e 11 caminhamentos elétricos com arranjo dipolo-dipolo de AB=MN=20 metros,com aproximadamente 1000m de extensão cada perfil. As SEVs foram dispostas nas linhas de modo a cobrir adequadamente a área do terreno, possibilitando a confecção de um mapa de contorno da profundidade do topo rochoso e a caracterização do perfil de alteração pedológico. Os caminhamentos elétricos foram dispostos paralelamente entre si e espaçados de 60 metros, podendo ser observadas as possíveis configurações do topo rochoso, como rocha não fraturada e zonas fraturadas. A partir dos dados dos caminhamentos elétricos foram elaboradas simulações 3D de resistividade e para a estimativa de volume de rocha não fraturada na área de estudo (com base nas resistividades mais elevadas).Os resultados obtidos mostraram a eficiência da eletrorresistividade na determinação do topo da rocha sã e detecção das zonas fraturadas no maciço granítico. / The geoeletric methods, especially electroresistivity, are being progressively more required on mining, for identifying soil thickness, fractured zones and geological heterogeneities, to check economical viability of mining projects. This work, held in Cabo de Santo Agostinho-PE city, presents and discusses geophysics application results of electroresistivity as a tool for helping the opening of a new granitic blocks exploitation front. The soil thickness was investigated, as well as the main local fault zones and fractures. A total of 32 VESs (03 VESs per section, exception made to line 11, with 02 VESs) using Schlumberger array with AB/2 maximum of 60 m, and 11 geoelectrical profilings using dipole-dipole array (AB=MN=20 m), with section lengths close to 1000 m. The VESs lines were organized in order to cover the studied area properly, allowing mapping the top of the rock massif and characterizing the soil profile. The geoelectrical profilings were disposed parallel with 60 m gap among each other, enabling the observation of the massif top configurations, such as fractured and non fractured zones. 3D resistivity simulations were performed using the geoelectrical profilings data in order to estimate the total volume of non fractured rock in the studied area (based on the highest resistivities). The obtained data showed the efficiency of electroresistivity for fractured zones detection and for mapping the top of the fresh rock massif.
8

The Viability of Using Trusted Execution Environments to Protect Data in Node-RED : A study on using AMD-SEV and Intel SGX to protect sensitive data when Node-RED is deployed on the cloud. / Möjligheten att använda Trusted Execution Environments för att skydda data i Node-RED : En studie om användandet av AMD-SEV och Intel SGX för att skydda känslig data när Node-RED körs på molnet.

Leijonberg, Carl January 2021 (has links)
The Internet of Things (IoT) consists of a network of physical devices that are connected over the internet for the purpose of exchanging data with other devices and systems. IoT platforms, such as Node-RED, have been introduced in recent times to facilitate communication between different IoT devices. Hosting Node-RED on a cloud service provider might result in the confidentiality of sensitive data on Node-RED being violated by malicious attackers, since users are forced to entrust their sensitive data with the cloud service providers. Using trusted execution environments, such as AMD-SEV and Intel SGX, can mitigate several potential attacks from exposing sensitive information in Node-RED. This thesis investigates if AMD-SEV and Intel SGX are viable options to protect sensitive data in Node-RED when hosted on a cloud service provider. The work in this thesis investigates difficulties encountered when deploying Node-RED on AMD-SEV and Intel SGX, from a usability perspective. Usability is measured by running Node-RED in AMDSEV and Intel SGX, and then recording the complexity of the process. Several performance tests are conducted to measure the performance overhead of Node-RED caused by AMD-SEV. A literature review is also conducted to investigate potential vulnerabilities in AMD-SEV and Intel SGX that could undermine the security of user’s data in Node-RED. The results from this thesis finds that AMD-SEV is a viable option to protect sensitive data in Node-RED when hosted on a cloud service provider. Deploying Node-RED on AMD-SEV is found to be a relatively simple process from a usability perspective. There are some noticeable performance overhead with regards to CPU utilization and TCP throughput, but all other metrics show marginal performance overhead. The potential vulnerabilities in AMD-SEV are not found to be significant enough to make AMD-SEV unviable. The thesis finds Intel SGX to be an unviable solution primarily due to usability. The process of running Node-RED in an Intel SGX enclave is extremely complex and the results show that for most users of Node-RED, this is not viable. The security vulnerabilities found from the literature review, are not significant enough to make Intel SGX an unviable option to protect sensitive user data inNode-RED. / Internet of Things (IoT) är en nätverk av fysiska enheter som är sammankopplade via internet för att kunna skicka data till andra fysiska enheter eller system. IoTplattformar, som Node-RED, har utvecklats för att förenkla kommunikationen mellan olika IoT- enheter. Att köra Node-RED på en molntjänst kan leda till att sekretessen av känslig data på Node-RED blir kränkt av en attack mot molntjänsten. Det är på grund av att användarna av Node-RED är tvungna att tillförlita deras känsliga data till molntjänsten, som deras data kan bli kränkt. Detta problem kan förminskas genom att användarna utnyttjar trusted execution environments som AMD-SEV och Intel SGX för att skydda sin känsliga data på molntjänsten. I denna avhandling, undersöks det om AMDSEV och Intel SGX kan användas för att skydda data i Node-RED när den körs på en molntjänst. Användarvänligheten av att köra Node-RED med AMD-SEV och Intel SGX undersöks genom att uppskatta hur komplicerad denna process är. Flera tester genomförs också för att mäta vilken påverkan AMD-SEV har på prestandan av Node-RED. En litteraturöversikt genomförs också för att undersöka potentiella sårbarheter i AMD-SEV och Intel SGX som skulle kunna utnyttjas för att komma åt känslig data i Node-RED. Resultaten från avhandlingen visar att AMD-SEV kan vara användbart för att skydda känslig data i Node-RED när den körs på en molntjänst. AMDSEV är väldigt användarvänlig när Node-RED ska köras. AMD-SEV har en märkbar påverkan på prestandan av processorn och TCP- genomströmning, men för de andra faktorerna som mäts har AMD-SEV ingen större påverkan. Litteraturöversikten finner inga sårbarheter som är tillräckligt farliga för att göra AMD-SEV oanvändbar för att skydda känslig data iNode-RED. Resultaten från avhandlingen visar dock att Intel SGX inte är särskilt användbar för att skydda känslig data i Node-RED när den körs på en molntjänst. Detta är främst för att det är väldigt komplicerat att köra Node-RED i en Intel SGX enklav från en användarvänlighet synpunkt. De flesta av Node-REDs användare skulle finna det för komplicerat att använda Intel SGX för att skydda sin känsliga data. Litteraturöversikten finner inga sårbarheter allvarliga nog för att göra Intel SGX oanvändbar.
9

Mapeamento Geoelétrico TDEM por meio da técnica Tx-Fixo e Rx-Móvel Aplicado em Estudos Hidrogeológicos na região central da Bacia de Taubaté-SP / TDEM Geoelectrical mapping by Tx fixed and Rx mobile technique applied in hydrogeological studies in central region of Taubaté basin-SP.

Hamada, Luiz Rodrigo 13 April 2018 (has links)
Nesta pesquisa foram analisados dados utilizando os métodos geofísicos Eletromagnético no Domínio do Tempo (TDEM) e Eletrorresistividade (ER) adquiridos na região central da Bacia sedimentar de Taubaté-SP com a finalidade de contribuir com estudos hidrogeológicos e realizar uma caracterização geoelétrica da área. Os dados TDEM foram obtidos por meio da técnica de caminhamento TDEM (CTDEM) usando um loop transmissor (Tx) fixo e uma bobina receptora (Rx) - 3D móvel, também conhecida como técnica fixed-loop. Os dados de ER foram coletados utilizando a técnica de Sondagem Elétrica Vertical (SEV) e perfis de Caminhamento Elétrico (CE). A interpretação das camadas geoelétricas da subsuperfície foram realizadas por meio de inversões individuais TDEM, inversões conjunta 1D de SEV/TDEM coincidentes e de pseudoseções CTDEM geradas através da interpolação dos resultados das inversões individuais TDEM, permitindo, desta forma, gerar um modelo geoelétrico para a região específica dentro do loop transmissor. A área de estudos localiza-se numa área rural da cidade de Taubaté, SP, de maneira que os resultados dos perfis de CTDEM integrados com as inversões conjuntas SEV/TDEM e informações litológicas de poços permitiram mapear o contato entre os sedimentos Quaternários e Terciários (Grupo Taubaté e Formação Pindamonhangaba). O topo do embasamento da bacia na área de estudos foi inferido com base nas informações litológicas de poços catalogados e disponibilizados pelo Sistema de Informações de Águas Subterrâneas e pelo Serviço Geológico Brasileiro (SIAGAS-CPRM). Os resultados apresentam-se de acordo com as informações geológicas e contribuem com as pesquisas hidrogeofísicas no Estado de São Paulo. / In this research the geophysics data were analyzed through the Time Domain Electromagnetic Method (TDEM) and Electrical Method (DC), which one were acquired in central region of sedimentary Taubaté basin, SP, for the purpose to contribute to hydrogeological studies and perform a geoelectrical characterization of this area. TDEM data were obtained by 3D mobile receiver coil (Rx) and transmitter fixed-loop techniques. The DC data were collected using Vertical Electric Sounding (VES) and Electrical Resistivity Tomography (ERT) techniques. The geoelectrical layers interpretation of subsurface were performed by TDEM individual invertions and 1D joint inversions VES/TDEM and the TDEM profiles were generated through interpolation of TDEM individual inversions, allowing to generate a geoelectrical model to the specific region inside the loop transmitter. The study area is located around Taubaté city, SP, in a rural area, so that TDEM profile results associated with joint inversions VES/TDEM and wells lithological informations allows mapping the contact between Quaternary and Tertiary (Taubaté Group and Pindamonhangaba Formation) sediments. The top of the basement in the studies area was inferred through of wells informations available in Groundwater Information System and Brazilian Geological Service (SIAGAS-CPRM). The results are consistent with geological informations, contributing with hydrogeophysical studies at São Paulo state.
10

Mapeamento Geoelétrico TDEM por meio da técnica Tx-Fixo e Rx-Móvel Aplicado em Estudos Hidrogeológicos na região central da Bacia de Taubaté-SP / TDEM Geoelectrical mapping by Tx fixed and Rx mobile technique applied in hydrogeological studies in central region of Taubaté basin-SP.

Luiz Rodrigo Hamada 13 April 2018 (has links)
Nesta pesquisa foram analisados dados utilizando os métodos geofísicos Eletromagnético no Domínio do Tempo (TDEM) e Eletrorresistividade (ER) adquiridos na região central da Bacia sedimentar de Taubaté-SP com a finalidade de contribuir com estudos hidrogeológicos e realizar uma caracterização geoelétrica da área. Os dados TDEM foram obtidos por meio da técnica de caminhamento TDEM (CTDEM) usando um loop transmissor (Tx) fixo e uma bobina receptora (Rx) - 3D móvel, também conhecida como técnica fixed-loop. Os dados de ER foram coletados utilizando a técnica de Sondagem Elétrica Vertical (SEV) e perfis de Caminhamento Elétrico (CE). A interpretação das camadas geoelétricas da subsuperfície foram realizadas por meio de inversões individuais TDEM, inversões conjunta 1D de SEV/TDEM coincidentes e de pseudoseções CTDEM geradas através da interpolação dos resultados das inversões individuais TDEM, permitindo, desta forma, gerar um modelo geoelétrico para a região específica dentro do loop transmissor. A área de estudos localiza-se numa área rural da cidade de Taubaté, SP, de maneira que os resultados dos perfis de CTDEM integrados com as inversões conjuntas SEV/TDEM e informações litológicas de poços permitiram mapear o contato entre os sedimentos Quaternários e Terciários (Grupo Taubaté e Formação Pindamonhangaba). O topo do embasamento da bacia na área de estudos foi inferido com base nas informações litológicas de poços catalogados e disponibilizados pelo Sistema de Informações de Águas Subterrâneas e pelo Serviço Geológico Brasileiro (SIAGAS-CPRM). Os resultados apresentam-se de acordo com as informações geológicas e contribuem com as pesquisas hidrogeofísicas no Estado de São Paulo. / In this research the geophysics data were analyzed through the Time Domain Electromagnetic Method (TDEM) and Electrical Method (DC), which one were acquired in central region of sedimentary Taubaté basin, SP, for the purpose to contribute to hydrogeological studies and perform a geoelectrical characterization of this area. TDEM data were obtained by 3D mobile receiver coil (Rx) and transmitter fixed-loop techniques. The DC data were collected using Vertical Electric Sounding (VES) and Electrical Resistivity Tomography (ERT) techniques. The geoelectrical layers interpretation of subsurface were performed by TDEM individual invertions and 1D joint inversions VES/TDEM and the TDEM profiles were generated through interpolation of TDEM individual inversions, allowing to generate a geoelectrical model to the specific region inside the loop transmitter. The study area is located around Taubaté city, SP, in a rural area, so that TDEM profile results associated with joint inversions VES/TDEM and wells lithological informations allows mapping the contact between Quaternary and Tertiary (Taubaté Group and Pindamonhangaba Formation) sediments. The top of the basement in the studies area was inferred through of wells informations available in Groundwater Information System and Brazilian Geological Service (SIAGAS-CPRM). The results are consistent with geological informations, contributing with hydrogeophysical studies at São Paulo state.

Page generated in 0.0228 seconds