• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 6
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação de manganês em amostras de cimento e clínquer por voltametria de redissolução catódica empregando eletrodos de ouro / Manganese determination in cement and clinker samples by cathodic stripping voltammetry using gold electrodes

Joca, Jhonny Frank Sousa 22 June 2011 (has links)
Este trabalho apresenta o desenvolvimento e a aplicação de um método alternativo para determinação de manganês em amostras de cimento e clínquer por voltametria de redissolução catódica por onda quadrada empregando eletrodos de ouro. Após estudos exploratórios acerca do comportamento eletroquímico do manganês no eletrólito suporte H3BO3 0,20 mol L-1 / KCl 0,10 mol L-1 com pH 6,5 e a otimização dos parâmetros operacionais para a voltametria de onda quadrada, foram obtidos excelentes resultados na determinação de manganês nas amostras analisadas. Destacam-se a ótima linearidade, verificada em duas faixas distintas de concentração, e os baixos limites de detecção e quantificação obtidos (3,1 x 10-8 mol L-1 e 9,8 x 10-8 mol L-1, respectivamente), além da concordância entre os resultados obtidos pela técnica eletroanalítica quando comparados aos resultados fornecidos pela espectrometria de absorção atômica de chama (FAAS). Para o tratamento das amostras foi avaliada a eficiência da extração ácida assistida por ultrassom. Foram avaliados ácidos minerais individualmente (HCl, H2SO4 e HClO4 em diferentes concentrações), em mistura ou ainda associados a H2O2. Os melhores resultados foram obtidos utilizando uma solução de HCl 3 mol L-1, que extraiu quantitativamente o manganês nas amostras analisadas. Os resultados obtidos foram concordantes com a metodologia padrão utilizada para a abertura da amostra e posterior análise por espectrometria de absorção atômica de chama, que emprega o aquecimento em chapa e a mesma solução extratora. / This work describes the development and application of a new alternative method for determination of manganese in cement and clinker samples by square wave cathodic stripping voltammetry using gold electrodes. After exploratory studies on the electrochemical behavior of manganese in H3BO3 0.20 mol L-1 / KCl 0.10 mol L-1 supporting electrolyte at pH 6.5 and the optimization of operating parameters for the square wave voltammetry, excellent results were obtained for determination of manganese in the samples analyzed. Most notable are the excellent linearity, verified in two distinct concentration bands and the low limits of detection and quantification obtained (3,1 x 10-8 mol L-1 e 9,8 x 10-8 mol L-1, respectively), in addiction to the concordance between the obtained results by the electroanalytical technique when compared to the provided by the flame atomic absorption spectrometry. For samples treatment were tested the efficiency of the ultrasound-assisted extraction. Were evaluated individually mineral acids (HCl, H2SO4 and HClO4 at different concentrations) in a mixture or associated with H2O2. the best results were obtained using a 3 mol L-1 HCl solution, which extracted manganese quantitatively from the analysed samples, in comparison to the standard method for extraction, targeting a later atomic absorption flame spectrometry analysis, which uses the plate heating and the same extracting solution. The obtained results for the analysed samples agrees with the cement and clinker samples of the used literature
2

Duloxetina : desenvolvimento e validação de métodos analíticos e estudos da estabilidade / Duloxetine : development and validation of analytical methods and stability studies

Gomes, Patricia January 2009 (has links)
A duloxetina (DLX) é um duplo inibidor seletivo balanceado da recaptação de serotonina e norepinefrina empregado para o tratamento do transtorno depressivo maior e para o manejo da dor neuropática diabética periférica. O objetivo deste estudo foi desenvolver e validar métodos analíticos para determinação de DLX em cápsulas e realizar estudos da estabilidade do fármaco. A substância usada como padrão de referência nas análises foi caracterizada por espectroscopia no infravermelho, ressonância magnética nuclear (RMN), calorimetria diferencial de varredura e espectrometria de massas. As análises qualitativas foram realizadas por cromatografia em camada delgada (CCD), espectrofotometria na região do ultravioleta (UV) e cromatografia líquida de alta eficiência (CLAE) permitindo a identificação do fármaco no produto farmacêutico. A espectrofotometria UV, CLAE e voltametria de redissolução catódica (CSV) foram validadas para determinação quantitativa de DLX em cápsulas. Estes métodos propostos foram específicos, robustos, lineares, precisos e exatos para determinação de DLX em microgrânulos de revestimento entérico. Estudos preliminares da estabilidade da DLX durante o desenvolvimento do método indicativo de estabilidade por CLAE demonstraram que o fármaco foi rapidamente degradado em meio ácido, na presença de peróxido de hidrogênio e de radiação a luz UVC, enquanto que este foi mais estável em meio alcalino. A cinética de degradação descreveu as mudanças na concentração da DLX em condição ácida e sob fotodegradação. A degradação ácida da DLX, em solução de HCl 0,1 M, mostrou cinética aparente de zero ordem e a fotodegradação demonstrou uma cinética aparente de primeira ordem. O produto de degradação principal observado na hidrólise ácida (PDA-14) foi analisado e isolado por CCD preparativa. Espectros de RMN-1H, RMN-13C e COSY foram avaliados e a estrutura do PDA-14 foi confirmada como 1-naftol. Esta substância produz efeitos citotóxicos e consequentemente o produto farmacêutico é uma cápsula de gelatina contendo microgrânulos com revestimento entérico para evitar a degradação ácida da DLX no estômago. / The duloxetine (DLX) is a double balanced selective serotonin and norepinephrinereuptake inhibitor employed for the treatment of major depressive disorder and for the management of diabetic peripheral neuropathic pain. The aim of this study was to develop and validate analytical methods to the determination of DLX in capsules and accomplish studies of this drug stability. The substance used as reference standard in the analysis was characterized by infrared spectroscopy, nuclear magnetic resonance (NMR), differential scanning calorimetry, and mass spectrometry. The qualitative analyses were performed by thin layer chromatography (TLC), ultraviolet spectrophotometry (UV), and high performance liquid chromatography (HPLC) allowing the identification of the drug in pharmaceutical dosage form. The UV spectrophotometry, HPLC, and cathodic stripping voltammetry (CSV) were validated for quantitative determination of the DLX in capsules. These proposed methods were specific, robust, linear, precise, and accurate to the determination of DLX in entericcoated pellets. Preliminary studies of DLX stability during the development of stability-indicating HPLC method demonstrated that the drug was rapidly degraded in acid medium, in the presence of hydrogen peroxide and light UVC radiation, while it was more stable in alkali medium. The kinetics of degradation described the concentration changes of DLX in acid condition and on photodegradation. The acid degradation of DLX in 0.1M HCl solution showed apparent zero-order kinetics and the photodegradation demonstrated apparent first-order kinetics. The main degradation product observed in acid hydrolysis (DP-14) was analyzed and isolated by TLC preparative. 1H NMR, 13C NMR and COSY spectra were evaluated and the structure of DP-14 was confirmed as 1-naphthol. This substance produces cytotoxic effects and consequently the finished pharmaceutical dosage form is a gelatin capsule containing enteric-coated pellets to avoid the acid degradation of DLX in the stomach.
3

Duloxetina : desenvolvimento e validação de métodos analíticos e estudos da estabilidade / Duloxetine : development and validation of analytical methods and stability studies

Gomes, Patricia January 2009 (has links)
A duloxetina (DLX) é um duplo inibidor seletivo balanceado da recaptação de serotonina e norepinefrina empregado para o tratamento do transtorno depressivo maior e para o manejo da dor neuropática diabética periférica. O objetivo deste estudo foi desenvolver e validar métodos analíticos para determinação de DLX em cápsulas e realizar estudos da estabilidade do fármaco. A substância usada como padrão de referência nas análises foi caracterizada por espectroscopia no infravermelho, ressonância magnética nuclear (RMN), calorimetria diferencial de varredura e espectrometria de massas. As análises qualitativas foram realizadas por cromatografia em camada delgada (CCD), espectrofotometria na região do ultravioleta (UV) e cromatografia líquida de alta eficiência (CLAE) permitindo a identificação do fármaco no produto farmacêutico. A espectrofotometria UV, CLAE e voltametria de redissolução catódica (CSV) foram validadas para determinação quantitativa de DLX em cápsulas. Estes métodos propostos foram específicos, robustos, lineares, precisos e exatos para determinação de DLX em microgrânulos de revestimento entérico. Estudos preliminares da estabilidade da DLX durante o desenvolvimento do método indicativo de estabilidade por CLAE demonstraram que o fármaco foi rapidamente degradado em meio ácido, na presença de peróxido de hidrogênio e de radiação a luz UVC, enquanto que este foi mais estável em meio alcalino. A cinética de degradação descreveu as mudanças na concentração da DLX em condição ácida e sob fotodegradação. A degradação ácida da DLX, em solução de HCl 0,1 M, mostrou cinética aparente de zero ordem e a fotodegradação demonstrou uma cinética aparente de primeira ordem. O produto de degradação principal observado na hidrólise ácida (PDA-14) foi analisado e isolado por CCD preparativa. Espectros de RMN-1H, RMN-13C e COSY foram avaliados e a estrutura do PDA-14 foi confirmada como 1-naftol. Esta substância produz efeitos citotóxicos e consequentemente o produto farmacêutico é uma cápsula de gelatina contendo microgrânulos com revestimento entérico para evitar a degradação ácida da DLX no estômago. / The duloxetine (DLX) is a double balanced selective serotonin and norepinephrinereuptake inhibitor employed for the treatment of major depressive disorder and for the management of diabetic peripheral neuropathic pain. The aim of this study was to develop and validate analytical methods to the determination of DLX in capsules and accomplish studies of this drug stability. The substance used as reference standard in the analysis was characterized by infrared spectroscopy, nuclear magnetic resonance (NMR), differential scanning calorimetry, and mass spectrometry. The qualitative analyses were performed by thin layer chromatography (TLC), ultraviolet spectrophotometry (UV), and high performance liquid chromatography (HPLC) allowing the identification of the drug in pharmaceutical dosage form. The UV spectrophotometry, HPLC, and cathodic stripping voltammetry (CSV) were validated for quantitative determination of the DLX in capsules. These proposed methods were specific, robust, linear, precise, and accurate to the determination of DLX in entericcoated pellets. Preliminary studies of DLX stability during the development of stability-indicating HPLC method demonstrated that the drug was rapidly degraded in acid medium, in the presence of hydrogen peroxide and light UVC radiation, while it was more stable in alkali medium. The kinetics of degradation described the concentration changes of DLX in acid condition and on photodegradation. The acid degradation of DLX in 0.1M HCl solution showed apparent zero-order kinetics and the photodegradation demonstrated apparent first-order kinetics. The main degradation product observed in acid hydrolysis (DP-14) was analyzed and isolated by TLC preparative. 1H NMR, 13C NMR and COSY spectra were evaluated and the structure of DP-14 was confirmed as 1-naphthol. This substance produces cytotoxic effects and consequently the finished pharmaceutical dosage form is a gelatin capsule containing enteric-coated pellets to avoid the acid degradation of DLX in the stomach.
4

Duloxetina : desenvolvimento e validação de métodos analíticos e estudos da estabilidade / Duloxetine : development and validation of analytical methods and stability studies

Gomes, Patricia January 2009 (has links)
A duloxetina (DLX) é um duplo inibidor seletivo balanceado da recaptação de serotonina e norepinefrina empregado para o tratamento do transtorno depressivo maior e para o manejo da dor neuropática diabética periférica. O objetivo deste estudo foi desenvolver e validar métodos analíticos para determinação de DLX em cápsulas e realizar estudos da estabilidade do fármaco. A substância usada como padrão de referência nas análises foi caracterizada por espectroscopia no infravermelho, ressonância magnética nuclear (RMN), calorimetria diferencial de varredura e espectrometria de massas. As análises qualitativas foram realizadas por cromatografia em camada delgada (CCD), espectrofotometria na região do ultravioleta (UV) e cromatografia líquida de alta eficiência (CLAE) permitindo a identificação do fármaco no produto farmacêutico. A espectrofotometria UV, CLAE e voltametria de redissolução catódica (CSV) foram validadas para determinação quantitativa de DLX em cápsulas. Estes métodos propostos foram específicos, robustos, lineares, precisos e exatos para determinação de DLX em microgrânulos de revestimento entérico. Estudos preliminares da estabilidade da DLX durante o desenvolvimento do método indicativo de estabilidade por CLAE demonstraram que o fármaco foi rapidamente degradado em meio ácido, na presença de peróxido de hidrogênio e de radiação a luz UVC, enquanto que este foi mais estável em meio alcalino. A cinética de degradação descreveu as mudanças na concentração da DLX em condição ácida e sob fotodegradação. A degradação ácida da DLX, em solução de HCl 0,1 M, mostrou cinética aparente de zero ordem e a fotodegradação demonstrou uma cinética aparente de primeira ordem. O produto de degradação principal observado na hidrólise ácida (PDA-14) foi analisado e isolado por CCD preparativa. Espectros de RMN-1H, RMN-13C e COSY foram avaliados e a estrutura do PDA-14 foi confirmada como 1-naftol. Esta substância produz efeitos citotóxicos e consequentemente o produto farmacêutico é uma cápsula de gelatina contendo microgrânulos com revestimento entérico para evitar a degradação ácida da DLX no estômago. / The duloxetine (DLX) is a double balanced selective serotonin and norepinephrinereuptake inhibitor employed for the treatment of major depressive disorder and for the management of diabetic peripheral neuropathic pain. The aim of this study was to develop and validate analytical methods to the determination of DLX in capsules and accomplish studies of this drug stability. The substance used as reference standard in the analysis was characterized by infrared spectroscopy, nuclear magnetic resonance (NMR), differential scanning calorimetry, and mass spectrometry. The qualitative analyses were performed by thin layer chromatography (TLC), ultraviolet spectrophotometry (UV), and high performance liquid chromatography (HPLC) allowing the identification of the drug in pharmaceutical dosage form. The UV spectrophotometry, HPLC, and cathodic stripping voltammetry (CSV) were validated for quantitative determination of the DLX in capsules. These proposed methods were specific, robust, linear, precise, and accurate to the determination of DLX in entericcoated pellets. Preliminary studies of DLX stability during the development of stability-indicating HPLC method demonstrated that the drug was rapidly degraded in acid medium, in the presence of hydrogen peroxide and light UVC radiation, while it was more stable in alkali medium. The kinetics of degradation described the concentration changes of DLX in acid condition and on photodegradation. The acid degradation of DLX in 0.1M HCl solution showed apparent zero-order kinetics and the photodegradation demonstrated apparent first-order kinetics. The main degradation product observed in acid hydrolysis (DP-14) was analyzed and isolated by TLC preparative. 1H NMR, 13C NMR and COSY spectra were evaluated and the structure of DP-14 was confirmed as 1-naphthol. This substance produces cytotoxic effects and consequently the finished pharmaceutical dosage form is a gelatin capsule containing enteric-coated pellets to avoid the acid degradation of DLX in the stomach.
5

Determinação de manganês em amostras de cimento e clínquer por voltametria de redissolução catódica empregando eletrodos de ouro / Manganese determination in cement and clinker samples by cathodic stripping voltammetry using gold electrodes

Jhonny Frank Sousa Joca 22 June 2011 (has links)
Este trabalho apresenta o desenvolvimento e a aplicação de um método alternativo para determinação de manganês em amostras de cimento e clínquer por voltametria de redissolução catódica por onda quadrada empregando eletrodos de ouro. Após estudos exploratórios acerca do comportamento eletroquímico do manganês no eletrólito suporte H3BO3 0,20 mol L-1 / KCl 0,10 mol L-1 com pH 6,5 e a otimização dos parâmetros operacionais para a voltametria de onda quadrada, foram obtidos excelentes resultados na determinação de manganês nas amostras analisadas. Destacam-se a ótima linearidade, verificada em duas faixas distintas de concentração, e os baixos limites de detecção e quantificação obtidos (3,1 x 10-8 mol L-1 e 9,8 x 10-8 mol L-1, respectivamente), além da concordância entre os resultados obtidos pela técnica eletroanalítica quando comparados aos resultados fornecidos pela espectrometria de absorção atômica de chama (FAAS). Para o tratamento das amostras foi avaliada a eficiência da extração ácida assistida por ultrassom. Foram avaliados ácidos minerais individualmente (HCl, H2SO4 e HClO4 em diferentes concentrações), em mistura ou ainda associados a H2O2. Os melhores resultados foram obtidos utilizando uma solução de HCl 3 mol L-1, que extraiu quantitativamente o manganês nas amostras analisadas. Os resultados obtidos foram concordantes com a metodologia padrão utilizada para a abertura da amostra e posterior análise por espectrometria de absorção atômica de chama, que emprega o aquecimento em chapa e a mesma solução extratora. / This work describes the development and application of a new alternative method for determination of manganese in cement and clinker samples by square wave cathodic stripping voltammetry using gold electrodes. After exploratory studies on the electrochemical behavior of manganese in H3BO3 0.20 mol L-1 / KCl 0.10 mol L-1 supporting electrolyte at pH 6.5 and the optimization of operating parameters for the square wave voltammetry, excellent results were obtained for determination of manganese in the samples analyzed. Most notable are the excellent linearity, verified in two distinct concentration bands and the low limits of detection and quantification obtained (3,1 x 10-8 mol L-1 e 9,8 x 10-8 mol L-1, respectively), in addiction to the concordance between the obtained results by the electroanalytical technique when compared to the provided by the flame atomic absorption spectrometry. For samples treatment were tested the efficiency of the ultrasound-assisted extraction. Were evaluated individually mineral acids (HCl, H2SO4 and HClO4 at different concentrations) in a mixture or associated with H2O2. the best results were obtained using a 3 mol L-1 HCl solution, which extracted manganese quantitatively from the analysed samples, in comparison to the standard method for extraction, targeting a later atomic absorption flame spectrometry analysis, which uses the plate heating and the same extracting solution. The obtained results for the analysed samples agrees with the cement and clinker samples of the used literature
6

Point-of-care Sensors for Determination of Manganese in Clinical Applications

Kang, Wenjing 13 September 2016 (has links)
No description available.

Page generated in 0.0635 seconds