1

Avaliação in vitro da resistência de união do cerômero ao sistema de cimentação adesiva, através do teste de micro-tração. Efeito de diferentes tratamentos de superfície

Faria, Ricardo Pinheiro de [UNESP] 26 November 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-11-26Bitstream added on 2014-06-13T20:12:02Z : No. of bitstreams: 1 faria_rp_me_arafo.pdf: 2571722 bytes, checksum: 03eaaed6baf6d35de160ebd73d353c6a (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A proposta deste estudo foi avaliar in vitro a resistência de união do Cerômero Artglass (Heraeus/Kulzer) ao cimento resiniso RelyX (3M), através do teste de Micro-Tração. Os seguintes tratamentos de superfície foram investigados: microjateamento com óxido de alumínio (AO), Artglass Liquid (AL), Silano (S), ácido fluorídrico (HF) e ácido fosfórico (AF). Cinco espécimes cada qual consistindo de um par de cilindro (10x10 mm) foram confeccionados. As superfícies de união foram regularizadas através de desgaste com lixas abrasivas de granulação sequencial sob refrigeração. Os espécimes foram nomeados ao acaso e submetidos aos seguintes tratamentos antes da cimentação: grupo 1 (AO/AGL), grupo 2(AO/AF), grupo 3 (AO/AF/S), grupo 4 (AO/HF) e grupo 5 (AO/HF/S). Os espécimes aos pares foram cimentados com um sistema adesivo dual e cimento resinoso dual, de acordo com as recomendações do fabricante. Espécimes foram fotopolimerizados, armazenados por 48 horas a 37ºC e, posteriormente, termociclados. Com auxílio de um disco de diamente perpendicular a superfície de união, palitos com 1 mm2 de área de seção foram obtidos. Os valores de resistência de união (MPa) foram obtidos com auxílio de uma máquina de teste universal (MTS800). Resultados foram: grupo 1(29,39+-5,13), grupo 2 (27,49 +- 5,32), grupo 3(29,49 +- 4,94), grupo 4(24,41 +- 2,67), e grupo 5 (22,19 +- 2,33). ANOVA e o Teste de Tukey foram aplicados com p<0,05. Não houve diferenças estatisticamente significante entre os grupo 1,2 e 3; 4 e 5; e 2 e 4. As forças de união foram significantemente maiores nos grupos 1 e 3 do que nos grupos 4 e 5; e no grupo 2 do que o grupo 5. Conclusões: Microjateamento com óxido de alumínio e Artglass Liquid foi um pré-tratamento de superfície efetivo; a sinalização pode melhorar a força de união promovida pelo microjateamento e condicionamento... . / The purpose of this study was to investigate the effect of surface treatments on microtensile interfacial bond strength of a composite Artglass (Kulzer) to resin cement RelyX (3M). Methods of surfaces roughening or preparation included microetching with aluminum oxide (AO), Artglass Liquid (AGL), Silane (S), hydrofluoric acid (HF), and fosforic acid (AF). Five specimens, each consisting of a pair of cylinders (10x10 mm) were fabricated. The bonding surfaces were finished with 600-grit silicon carbide paper. Specimen pairs were randomly assigned to one of five surface treatment groups: group 1 (AO/AGL), group 2 (AO/AF), group 3 (AO/AF/S), group 4 (AO/HF), and group 5 (AO/HF/S). Specimen pairs were cemented with a dual resin bonding and a dual cure resin cement, in accordance with the manufacturer's instructions. Specimens were light-cured, then thermocycled 500 times at between 5º C and 55º C. Using a diamond disk perpendicular to the bonding interface, sticks with 1.0 mm2 cross-sectional area were obtained. Microtensile bond strengths were determined using a MTS 800 Materials Testing Machine at a crosshead speed of 0.5 mm/min. Results: Means (n=20) and standard deviations of bond strengths (MPa) were: group 1 (29.39 +- 5.13), group 2(27.49 +- 5.32), group 3(29.49 +- 4.94), group 4 (24.41 +- 2.67), and group 5 (22.19 +- 2.33). Data were analyzed with ANOVA and Tukey Test at p<0.05. There were no significant statistical differences among the groups 1,2, and group 3; groups 4 and 5; and groups 2 and 4. Microtensile bond strengths were significantly higher in groups 1 and 3 than in groups 4 and 5; and in group 2 than in group 5. Conclusions: AO and AGL was an effective surface pretreatment; silanation may improve the bond provided by AO and etching with AF; and etching with HF is not recommended, as it decreases bond strength.
2

Avaliação pelo método dos elementos finitos de cargas axiais aplicadas sobre implantes e componentes protéticos com diversas inclinações /

Ferreira, Luciano Pedrin Carvalho. January 2007 (has links)
Resumo: O stress causado pela mastigação sobre implantes que se encontram muito inclinados, pode levar a tensões indesejáveis, causando até o fracasso da restauração. Este trabalho teve como objetivo apresentar através de simulações computacionais, as concentrações de tensões no implante e osso de suporte quando sua inclinação for maior que 30°. Para avaliação comportamental das tensões no implante/osso circundante, foi desenvolvido um modelo representando o primeiro pré-molar inferior. Foi utilizado o método dos elementos finitos bidimensional. Um modelo simulando um implante hexágono externo (4 mm x 15 mm) foi confeccionado, sofrendo inclinações de 30°, 35° e 40°, com uma carga de 100 N e 350 N, incidindo no sentido vertical. Através do enceramento de um componente ucla, a inclinação da coroa protética foi restabelecida. Os materiais de cobertura selecionados foram: porcelana, cerômero e o metal. No implante sem inclinação (controle), a tensão máxima ficou concentrada no local de aplicação da carga. Para os implantes angulados, as tensões se concentraram no local de aplicação da carga, no osso cortical e no terço cervical e médio do implante, no lado da inclinação, independentemente do material de cobertura utilizado. Com a limitação deste estudo, as cargas verticais são bem aceitas pelos implantes sem inclinação, mas quando angulados, a concentração de stress é muito maior no lado em que ocorre a inclinação. / Abstract: Tensions caused by mastication on very inclined implants can result in undesirable stresses as well as restoration failures. By means of computational simulations, present the concentrations of stresses on the implant and supporting bone when the inclination is greater than 30°. A model representing the first mandibular premolar was developed to evaluate stress behavior in the surrounding implant/bone, using the bidimensional finite element method. A model simulating an external hexagon implant (4 mm x 15 mm) was made, with 0°, 30°, 35° and 40°, a load of 100 N and 350 N, occurring in the vertical direction. The correct prosthetic crown inclination was reestablished by means of a UCLA component. The selected covering materials were: porcelain, ceromer and metal. In an implant without inclination (control), maximum stress was concentrated in the place of load application and on the middle third of the implant. For angled implants, the stress was concentrated on the side of the inclination, on the cortical bone and on the cervical and medium third of the implant. The covering material had similar behauvior. Within the limitations of this study, the vertical loads were well accepted by the implants without inclination, but when implants were angled, the stress concentration was much greater on the side inclination. The finite element method used to investigate inclined implants in the posterior area of the jaw, indicated that there was higher stress concentration where the inclination was. However, clinical studies are important to evaluate the amount of load necessary for bone reabsorption. / Orientador: José Cláudio Martins Segalla / Coorientador: Osvaldo Manzoli Filho / Banca: João Neudenir Arioli Filho / Banca: José Carlos Rabello Ribeiro / Mestre
3

Avaliação "in vitro" da resistência de união do cerômero ao sistema de cimentação adesiva, através do teste de micro-tração. Efeito de diferentes tratamentos de superfície /

Faria, Ricardo Pinheiro de. January 2001 (has links)
Orientador: Celso Luiz de Angelis Porto / Banca: José Roberto Cury Saad / Banca: João Carlos Gomes / Resumo: A proposta deste estudo foi avaliar "in vitro" a resistência de união do Cerômero Artglass (Heraeus/Kulzer) ao cimento resiniso RelyX (3M), através do teste de Micro-Tração. Os seguintes tratamentos de superfície foram investigados: microjateamento com óxido de alumínio (AO), Artglass Liquid (AL), Silano (S), ácido fluorídrico (HF) e ácido fosfórico (AF). Cinco espécimes cada qual consistindo de um par de cilindro (10x10 mm) foram confeccionados. As superfícies de união foram regularizadas através de desgaste com lixas abrasivas de granulação sequencial sob refrigeração. Os espécimes foram nomeados ao acaso e submetidos aos seguintes tratamentos antes da cimentação: grupo 1 (AO/AGL), grupo 2(AO/AF), grupo 3 (AO/AF/S), grupo 4 (AO/HF) e grupo 5 (AO/HF/S). Os espécimes aos pares foram cimentados com um sistema adesivo dual e cimento resinoso dual, de acordo com as recomendações do fabricante. Espécimes foram fotopolimerizados, armazenados por 48 horas a 37ºC e, posteriormente, termociclados. Com auxílio de um disco de diamente perpendicular a superfície de união, "palitos" com 1 mm2 de área de seção foram obtidos. Os valores de resistência de união (MPa) foram obtidos com auxílio de uma máquina de teste universal (MTS800). Resultados foram: grupo 1(29,39+-5,13), grupo 2 (27,49 +- 5,32), grupo 3(29,49 +- 4,94), grupo 4(24,41 +- 2,67), e grupo 5 (22,19 +- 2,33). ANOVA e o Teste de Tukey foram aplicados com p<0,05. Não houve diferenças estatisticamente significante entre os grupo 1,2 e 3; 4 e 5; e 2 e 4. As forças de união foram significantemente maiores nos grupos 1 e 3 do que nos grupos 4 e 5; e no grupo 2 do que o grupo 5. Conclusões: Microjateamento com óxido de alumínio e Artglass Liquid foi um pré-tratamento de superfície efetivo; a sinalização pode melhorar a força de união promovida pelo microjateamento e condicionamento... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The purpose of this study was to investigate the effect of surface treatments on microtensile interfacial bond strength of a composite Artglass (Kulzer) to resin cement RelyX (3M). Methods of surfaces roughening or preparation included microetching with aluminum oxide (AO), Artglass Liquid (AGL), Silane (S), hydrofluoric acid (HF), and fosforic acid (AF). Five specimens, each consisting of a pair of cylinders (10x10 mm) were fabricated. The bonding surfaces were finished with 600-grit silicon carbide paper. Specimen pairs were randomly assigned to one of five surface treatment groups: group 1 (AO/AGL), group 2 (AO/AF), group 3 (AO/AF/S), group 4 (AO/HF), and group 5 (AO/HF/S). Specimen pairs were cemented with a dual resin bonding and a dual cure resin cement, in accordance with the manufacturer's instructions. Specimens were light-cured, then thermocycled 500 times at between 5º C and 55º C. Using a diamond disk perpendicular to the bonding interface, "sticks" with 1.0 mm2 cross-sectional area were obtained. Microtensile bond strengths were determined using a MTS 800 Materials Testing Machine at a crosshead speed of 0.5 mm/min. Results: Means (n=20) and standard deviations of bond strengths (MPa) were: group 1 (29.39 +- 5.13), group 2(27.49 +- 5.32), group 3(29.49 +- 4.94), group 4 (24.41 +- 2.67), and group 5 (22.19 +- 2.33). Data were analyzed with ANOVA and Tukey Test at p<0.05. There were no significant statistical differences among the groups 1,2, and group 3; groups 4 and 5; and groups 2 and 4. Microtensile bond strengths were significantly higher in groups 1 and 3 than in groups 4 and 5; and in group 2 than in group 5. Conclusions: AO and AGL was an effective surface pretreatment; silanation may improve the bond provided by AO and etching with AF; and etching with HF is not recommended, as it decreases bond strength. / Mestre
4

Resistencia a flexão do sistema Targis/Vectris

Valcanaia, Dante del Vale 12 July 2000 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T11:53:38Z (GMT). No. of bitstreams: 1 Valcanaia_DantedelVale_M.pdf: 1768978 bytes, checksum: 067efd4d3b799f0bde3851b623815553 (MD5) Previous issue date: 2000 / Resumo: O efeito de reforços de fibra de vidro tem sido pesquisado, com o objetivo de melhorar as propriedades ffsicas de compostos resinosos. A elaboração de compostos fotopolimerizáveis à base de Bis-GMA, com grandes porcentagens de partículas inorgânicas deu origem aos Cerômeros. Estes materiais podem ser utilizados em restaurações indiretas posteriores, devido às propriedades de resistência à abrasão, assim como, em restaurações estéticas devido à translucidez. Da união destas duas tecnologias surgiram sistemas que aliam as propriedades dos Cerômeros, à alta resistência à flexão dos compósitos reforçados por fibras. Estes novos materiais são utilizados para confeccionar coroas e prótese parciais fixas anteriores e posteriores. O objetivo deste estudo foi verificar a resistência à flexão do sistema TargisNectris (lvoclar, Schaan, FL). Corpos de prova foram construidos em forma de barras híbridas, contendo subestrutura de compósito reforçado por fibras Vectris, e revestimento de composto particulado (Cerômero) Targis, com as seguintes dimensões: 6x5x30mm. Um ensaio de três pontos foi conduzido em uma máquina EMIC DL 500 MF e uma carga compressiva foi aplicada no centro das amostras,com espaço de 20mm entre os pontos de apoio. Um computador foi utilizado para calibrar as medições, programado para interromper o carregamento mecânico, quando ocorrer a fratura inicial (colapso de 10%). Após o ensaio, os corpos-de-prova foram cortados, metalizados e examinados com microscopia eletrônica de varredura. Os valores médios obtidos para os resultados das medidas de força de fratura foram de 963N e para medida de força por área de 197 MPa. A microscopia eletrônica de varredura revelou a existência de espaços vazios no interior do compósito reforçado por fibras (Vectris) e do Cerômero (Targis). Fraturas estavam presentes em ambos os compostos / Abstract: The effect of reinforcements of glass fiber has been researched, with the objective of improving the physical properties of composed resinous. The elaboration of light-cured compositions to the base of Bis-GMA, with great percentages of inorganic particles, originates the ceromer. These materials can be used for posterior indirect restorations, due to the resistance properties to the abrasion, as well as for aesthetic restorations due to the translucence. By the union of these two technologies systems that ally the properties of the ceromer to the high flexure strength of the fibers reinforced composites. These new materials are used to make crowns and anterior and posterior fixed bridges. The objective of this study went verify to flexure strength of the system TargisNectris (Ivoclar, Schaan, FL). Samples were built in form of hybrid bars, contends sub-structure of fibers reinforced composites Vectris and coating of particulate composite (ceromer) Targis, with the following dimensions: 6x5x30mm. A three-point test was driving by a machine EMIC and a compressive load it was applied in the center of the samples, with span length of 20mm. A computer was used to gauge the mensurations, programmed to interrupt the compression loading, when it happens the initial fracture (collapse of 10%). After the rehearsal, it body-of-proves them they were. cut, prepared metallographically and examined with scanning electronic microscopy. The mean values obtained for the results of the measures of fracture force were of 963 N and for measure of force for area of 197 MPa. The scanning electronic microscopy revealed the existence of void spaces inside the composite reinforced by fibers (Vectris) and of the ceromer (Targis). Unes of fractures were present in both composites / Mestrado / Mestre em Materiais Dentários
5

Comparación in vitro de la microdureza y rugosidad del cerómero antes y después de su exposición a una bebida energizante

Hidalgo Acuña, Nataly Celia 29 January 2020 (has links)
Objetivo: Comparar in vitro la microdureza y rugosidad superficial del cerómero antes y después de su exposición a una bebida energizante. Materiales y métodos: Este estudio fue de tipo experimental in vitro. Se evaluaron 20 discos tipo cilíndricos (6 mm de altura y 4 mm de ancho) del cerómero SR Adoro® divididos en dos grupos para evaluar la microdureza superficial y rugosidad superficial. El desafío erosivo se realizó por 30 minutos/1 vez/ 5 días con la bebida Red Bull®. El análisis estadístico que se utilizó para evaluar la microdureza superficial fue la prueba de Wilcoxon. Sin embargo, para evaluar la rugosidad superficial se utilizó la prueba de T Student. Resultados: Se encontraron diferencias estadísticamente significativas al evaluar la microdureza superficial. Sin embargo, no se encontraron diferencias significativas al evaluar la rugosidad superficial del cerómero. La media y desviación estándar de la microdureza superficial del cerómero SR Adoro® antes del desafío erosivo fue de 55.45 + 6.42 MPa y después del desafío erosivo fue de 38.24 + 6.09 MPa. La diferencia de microdureza superficial inicial y final fue de 17.21+ 0.33 MPa. La media y desviación estándar de la rugosidad del cerómero SR Adoro® antes del desafío erosivo fue de 1.66 + 0.30 y después fue de 1.703 + 0.43 µm. La diferencia de rugosidad inicial y final del cerómero SR Adoro® expuesta a la bebida (Red Bull®) fue de 0.04+ 0.33 µm. Conclusiones: Existen diferencias estadísticamente significativas al evaluar la microdureza superficial. Sin embargo, no se encontraron diferencias estadísticamente significativas al evaluar la rugosidad del cerómero SR Adoro® (p<0.05; p=0.808) al ser expuesta a una bebida energizante Red Bull®. / Objective: To compare in vitro the superficial microhardness and roughness of the ceromer before and after being exposed to an energizing drink. Materials and methods: This study was of experimental type in vitro. Twenty cylindrical discs (6 mm high and 4 mm wide) of the SR Adoro® ceromer were divided into two groups to evaluate the surface microhardness and surface roughness. The erosive challenge was performed for 30 minutes / 1 time / 5 days with the Red Bull® drink. The statistical analysis that was used to evaluate the surface microhardness was the Wilcoxon test. However, the Student's T test was used to evaluate the surface roughness. Results: Statistically significant differences were found when evaluating surface microhardness. However, no significant differences were found when evaluating the roughness of the ceromer. The mean and standard deviation of the surface microhardness of the SR Adoro® ceromer before the erosive challenge was 55.45 + 6.42 MPa and after the erosive challenge was 38.24 + 6.09 MPa. The difference of initial and final surface microhardness was 17.21 + 0.33 µm. The mean and standard deviation of the rugosity of the SR Adoro® ceromer before the erosive challenge was 1.66 + 0.30 µm and then was 1.703 + 0.43 µm. The initial and final roughness difference of the SR Adoro® ceromer exposed to the beverage (Red Bull®) was 0.04 + 0.33 µm. Conclusions: There are statistically significant differences when evaluating surface microhardness. However, no statistically significant differences were found when assessing the rugosity of the SR Adoro® ceromer (p<0.05, p = 0.808) when exposed to a Red Bull® energy drink. / Tesis
6

Avaliação pelo método dos elementos finitos de cargas axiais aplicadas sobre implantes e componentes protéticos com diversas inclinações

Ferreira, Luciano Pedrin Carvalho [UNESP] 24 April 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-04-24Bitstream added on 2014-06-13T20:37:51Z : No. of bitstreams: 1 ferreira_lpc_me_arafo.pdf: 814817 bytes, checksum: a1d0c7e92cf1ea3e5ea3d8dc8b1d5863 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O stress causado pela mastigação sobre implantes que se encontram muito inclinados, pode levar a tensões indesejáveis, causando até o fracasso da restauração. Este trabalho teve como objetivo apresentar através de simulações computacionais, as concentrações de tensões no implante e osso de suporte quando sua inclinação for maior que 30°. Para avaliação comportamental das tensões no implante/osso circundante, foi desenvolvido um modelo representando o primeiro pré-molar inferior. Foi utilizado o método dos elementos finitos bidimensional. Um modelo simulando um implante hexágono externo (4 mm x 15 mm) foi confeccionado, sofrendo inclinações de 30°, 35° e 40°, com uma carga de 100 N e 350 N, incidindo no sentido vertical. Através do enceramento de um componente ucla, a inclinação da coroa protética foi restabelecida. Os materiais de cobertura selecionados foram: porcelana, cerômero e o metal. No implante sem inclinação (controle), a tensão máxima ficou concentrada no local de aplicação da carga. Para os implantes angulados, as tensões se concentraram no local de aplicação da carga, no osso cortical e no terço cervical e médio do implante, no lado da inclinação, independentemente do material de cobertura utilizado. Com a limitação deste estudo, as cargas verticais são bem aceitas pelos implantes sem inclinação, mas quando angulados, a concentração de stress é muito maior no lado em que ocorre a inclinação. / Tensions caused by mastication on very inclined implants can result in undesirable stresses as well as restoration failures. By means of computational simulations, present the concentrations of stresses on the implant and supporting bone when the inclination is greater than 30°. A model representing the first mandibular premolar was developed to evaluate stress behavior in the surrounding implant/bone, using the bidimensional finite element method. A model simulating an external hexagon implant (4 mm x 15 mm) was made, with 0°, 30°, 35° and 40°, a load of 100 N and 350 N, occurring in the vertical direction. The correct prosthetic crown inclination was reestablished by means of a UCLA component. The selected covering materials were: porcelain, ceromer and metal. In an implant without inclination (control), maximum stress was concentrated in the place of load application and on the middle third of the implant. For angled implants, the stress was concentrated on the side of the inclination, on the cortical bone and on the cervical and medium third of the implant. The covering material had similar behauvior. Within the limitations of this study, the vertical loads were well accepted by the implants without inclination, but when implants were angled, the stress concentration was much greater on the side inclination. The finite element method used to investigate inclined implants in the posterior area of the jaw, indicated that there was higher stress concentration where the inclination was. However, clinical studies are important to evaluate the amount of load necessary for bone reabsorption.

Page generated in 0.0489 seconds