• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 2
  • Tagged with
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Acquisition de la maladie du légionnaire suite à une exposition domestique

Duchesne, Annie January 2004 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
2

Optimisation du cycle de fonctionnement d'un chauffe-eau thermodynamique résidentiel / Air Source Heat Pump Water Heaters, modeling, simulation and multi-criteria based optimization

Deutz, Kevin Ruben 26 January 2018 (has links)
Le chauffe-eau thermodynamique (CET), dont le principe repose sur une pompe à chaleur (PAC), est l’une des principales solutions pour répondre à l’enjeu de réduction des consommations énergétiques des bâtiments liées à l’eau chaude sanitaire. Le CET le plus courant sur le marché français est composé d’une PAC sur air extérieur, au R134a, dont le condenseur est de type manteau, entourant le ballon de stockage. Bien que le système arrive à maturité, les performances annuelles semblent encore loin des performances théoriques. Cette thèse a donc pour objectif l’optimisation des performances énergétiques des CET, en partant du CET standard français, selon un principe de compromis technico-économique. Pour cela, un modèle détaillé du CET standard est élaboré. La PAC est modélisée sous Dymola à l’aide de la bibliothèque TIL. Le ballon de stockage est modélisé par une combinaison d’une approche zonale et d’un modèle 1D. Ce modèle détaillé est calibré et validé expérimentalement grâce à des essais d’un CET standard réalisé en enceintes climatiques. Ce modèle est ensuite utilisé pour identifier les principaux gisements d’économie d’énergie. Une première analyse permet d’identifier les paramètres les plus influents sur les performances du CET. Cette sélection conduit ensuite à l’élaboration d’un modèle simplifié, plus apte à étudier des périodes longues de fonctionnement en intégrant des critères de coût et de confort. Une étude spécifique, à l’aide d’un algorithme génétique, permet d’évaluer le potentiel d’optimisation lié au pilotage du CET. Une étude multi-paramétrique montre ensuite que le design des échangeurs joue également un rôle important. Les résultats de ces deux voies prometteuses d’optimisation du CET étant inter-dépendants, une dernière partie consiste en une étude multi-critère. Les résultats montrent qu’avec la nouvelle configuration proposée sont obtenus, un meilleur confort thermique sur une plus large gamme de scénario, une augmentation de COP moyenne annuelle de 37 % et une réduction moyenne de facture électrique de 30 %. / Heat Pump Water Heaters (HPWH) are efficient and fast-developing sanitary hot water production systems relying on a heat pump thermodynamic cycle for heat generation, consequently offering a considerable energy saving potential in the buildings sector. The most forthcoming HPWH on the French market are Air-Source Heat Pump Water Heaters (ASHPWH) composed of an exterior air source R134a heat pump and using a wrap-around type condenser, surrounding the thermal storage tank (TST). However, it is found that although these ASHPWH have reached an important level of maturity, it seems that there is still room for improvement of their energy performance. Consequently, the main objective of this PhD thesis is to search for optimization pathways, starting of from the reference ASHPWH on the French market, leading a better technical and economical compromise in terms of ASHPWH design. To reach this objective, a detailed model is first developed using Dymola (Modelica langage). This model comprises of a zonal model and a 1D model for the TST associated to an air source heat pump modeled with the TIL thermal component modeling library. After model calibration, the model is validated thanks to a large set of experimental tests carried out on a standard ASHPWH in climatic cells. The validated model is then used to identify optimization pathways by carrying out annual simulations and identifying energy performance improvement potentials. It is found out that both thermodynamic cycle performance and improved ASHPWH control logics are major contributors to the final energy performance. Both being highly interdependent and impacting energy performances, but also comfort and ASHPWH cost, the last part of the study consists of a multi-criteria optimization. Finally, a new ASHPWH design is proposed achieving better thermal comfort upon a large variety of user draw-off profiles, achieving a 37 % average annual energy saving and a 30 % reduction of the electrical bill.
3

Optimisation des installations solaires collectives d'eau chaude sanitaire : application des techniques « des faibles débits » et « du stockage divisé »

Johannes, Kévyn 10 November 2005 (has links) (PDF)
Les installations de production d'eau chaude solaire collective ayant peu évolué ces vingt dernières années, il paraissait important de rechercher des innovations afin de les améliorer d'un point de vue technico-économique.<br />Nous avons ainsi conçu un ballon de stockage à stratification, fonctionnant aussi bien dans les installations individuelles que dans les installations collectives.<br />La simulation du comportement d'un ballon domestique puis collectif grâce au code CFD Fluent a permis de mettre en évidence l'influence positive de la présence d'injecteurs à plaques sur les entrées solaires ainsi que sur l'entrée d'eau froide.<br />Les résultats expérimentaux, obtenus grâce à la mise en place d'un banc expérimental, ont permis de valider le modèle CFD ainsi que l'utilisation des injecteurs à plaques vis-à-vis de la stratification thermique. Une étude par injection de colorant a également permis d'étudier qualitativement la stratification au sein du ballon.<br />L'objectif du travail étant d'optimiser les installations solaires d'eau chaude collective, nous avons élaboré un modèle avec le logiciel TRNSYS. Il permet de simuler l'ensemble des composants intervenant dans la production solaire d'eau chaude sanitaire de telles installations. La validation du modèle de référence développé a été réalisée grâce à des données expérimentales. En effet, l'installation solaire de la maison de retraite « Les Berges de l'Hyères » située à Chambéry (73) a été instrumentée de façon à obtenir notamment le bilan énergétique aux bornes de chaque composant. La comparaison des résultats expérimentaux et numériques indique la cohérence du modèle, bien que des différences, néanmoins explicables, persistent.<br />Ce modèle a ensuite servi de base de comparaison dans la proposition d'installations innovantes plus performantes sur le plan énergétique. La comparaison des différentes solutions est basée sur le taux de couverture solaire corrigé. Contrairement au taux de couverture défini dans la Garantie de Résultats Solaires (GRS), le taux de couverture solaire corrigé considère l'énergie d'appoint ainsi que l'énergie nécessaire au fonctionnement des auxiliaires. Les conclusions à l'issue de ces simulations sont très satisfaisantes. En effet, les installations solaires collectives décentralisées atteignent des taux de couverture solaire corrigés de 30% et réduisent ainsi sensiblement les rejets de CO2. Nous avons également mis en évidence l'intérêt de faire fonctionner l'installation en débit variable. L'alimentation des pompes grâce à des cellules photovoltaïques est également très prometteuse.<br />Enfin, l'analyse économique montre que les installations à production solaire centralisée et à appoint individualisé, ainsi que les installations décentralisées, permettent d'effectuer des économies non négligeables sur la fourniture de l'énergie d'appoint. Cependant, l'investissement initial est fonction du nombre de ballons mis en place, et par conséquent, les temps de retour sont plus ou moins intéressants.
4

Contribution au pilotage de la charge pour accroître la flexibilité du système électrique. / The contribution of load control in increasing electric system flexibility

Saker, Nathalie 30 January 2013 (has links)
Les défis environnementaux et l’augmentation de la population viennent en preuve de l’importance de réfléchir à d’autres moyens de production tout en maintenant la sécurité et la fiabilité du système électrique. La sûreté du système électrique exige à tout moment que la production soit égale à la demande des consommateurs, pour ça, différentes solutions sont déjà mises en place, ces solutions consistent à mettre en marche des moyens de pointes couteux et polluants pendant les périodes de pointes, mais comme les moyens de production son insuffisants et vue la difficulté d’exploitation de nouveaux moyens de production, une nouvelle réflexion sur la gestion de la demande est apparue; celle-ci se base sur la possibilité à gérer la demande du consommateur final au lieu de la satisfaire.L’objectif de la thèse est d’étudier la possibilité à rendre des services au système électrique en appliquant des actions de contrôle dites de DR (Demand Response), sur différents types de charges électriques. Ces actions de DR représentent des interruptions partielles appliquées sur les charges électriques de type thermique. Notre choix s’est basé sur ces types de charges parce que celles-ci emmagasinent de la chaleur respectivement dans l’air et dans l’eau; qui peut être restituée pendant la période de contrôle ou d’interruption. Néanmoins, il existe un effet négatif qui suit le contrôle de ces charges car l’énergie effacée de ces charges est reportée à l’instant de reconnexion de celles-ci; ce report prend la forme d’un pic de consommation nommé CLPU (Cold Load Pick-Up) et qui apparait au moment de la reconnexion. Le CLPU représente un problème qui doit être géré, et sa magnitude dépend des types d’actions de contrôle qu’on veut implanter et aussi des conditions du système électrique (contingence, défaillance d’une unité de production ou besoin de réserve de puissance). Pendant la thèse, le CLPU est contrôlé et optimisé ainsi que la puissance effacée. Un cas d’étude est présenté sur la contribution des actions de gestion de la demande à l‘ajustement entre la demande et la production et l’effet généré sur le réglage secondaire de fréquence. / Environmental challenges and the increasing in electric demand show the importance of considering other form of production while maintaining the safety and reliability of the electrical system. The electrical power systems stability lays on a fundamental constraint: supply and demand must be equal at each instant, so, different solutions are already in place, these solutions include controlling generators’ production during peak periods. But, power units (mainly nuclear, thermal, hydro) capacities are not always sufficient and flexible to follow the demand variations during these periods; an alternative solution to this insufficiency is to make the demand following the electrical power generation by providing bulks of electrical power to the power system by curtailing consumer’s electric load consumption. Such a solution that represents a new organization in the power system industry can be done by Demand Side Management (DSM) actions. The aim of the thesis is to study the possibility to offer services to the electrical system by applying control actions called DR (Demand Response) on different types of electric loads. These DR actions represent partial interruptions of electrical loads’ consumption and especially thermal loads’ consumption.Our choice was based on the thermal electric loads because they store heat respectively in air and water, which can be restored during the control period or interruption. However, there is a negative effect that follows the control of these type of loads because the reduced energy during curtailment period is deferred at the time of reconnection, this deferred power takes the form of a power peak named CLPU (Cold Load Pick-Up), which appears at the time of reconnection. The CLPU is a problem that must be managed, and its magnitude depends on the type of control actions and on the electric system conditions (ie: contingency or failure of a generating unit). In the thesis, the CLPU is controlled and optimized as well as the load reduction during curtailment period. The contribution of control actions in balancing mechanisms and the effect produced on the secondary control of frequency are analyzed.
5

Modélisation et contrôle des ballons d'eau chaude sanitaire à effet Joule : du ballon individuel au parc / Modeling and control of electric hot water tanks : from the single unit to the group

Beeker-Adda, Nathanaël 13 July 2016 (has links)
Cette thèse s'intéresse au développement de stratégies de décalage de charge pouvant être appliquées à un parc de chauffe-eau Joule (CEJ).On propose une modélisation entrée-sortie du système que constitue le CEJ. L'idée est de concevoir un modèle précis et peu coûteux numériquement, qui pourrait être intégré dans un CEJ intelligent. On présente notamment un modèle phénoménologique multi-période d'évolution du profil de température dans le CEJ ainsi qu'un modèle de la demande en eau chaude. On étudie des stratégies d'optimisation pour un parc de CEJ dont la résistance peut être pilotée par un gestionnaire central. Trois cas de figures sont étudiés. Le premier concerne un petit nombre de ballons intelligents et présente une méthode de résolution d'un problème d'optimisation en temps discret. Puis, on s'intéresse à un parc de taille moyenne. Une heuristique gardant indivisibles les périodes de chauffe (pour minimiser les aléas thermo-hydrauliques) est présentée. Enfin, un modèle de comportement d'un nombre infini de ballon est présenté sous la forme d'une équation de Fokker-Planck. / This thesis focuses on the development of advanced strategies for load shifting of large groups of electric hot water tanks (EHWT).The first part of this thesis is dedicated to representing an EHWT as an input-output system. The idea is to design a simple, tractable and relatively accurate model that can be implemented inside a low-power computing unit embedded in a smart EHWT, for practical applications of optimization strategies. It includes in particular a phenomenological multi-period model of the temperature profile in the tank and a realistic domestic hot water consumption model.The second part focuses on the design of optimal control strategies for a group of tanks. Three use-cases are studied. The first one deals with a small number of smart and controllable EHWT for which we propose a discrete-time optimal resolution method. The second use-case adresses a medium-scale group of controllable tanks and proposes a heuristic which keeps the heating period undivided to minimize thermo-hydraulic hazards. Finally, we present the modelling of the behavior of a infinite population of tanks under the form of a Fokker-Planck equation.
6

Solar hot water production and thermal energy storage using phase change materials (PCMs) for solar air-conditioning applications in Morocco / Production de l’eau chaude solaire et stockage latent par matériaux à changement de phase (MCPs) pour les applications de rafraîchissement solaire au Maroc

Bouhal, Tarik 02 May 2019 (has links)
Cette thèse présente les résultats de recherche, de modélisation et de simulation d'un système de rafraîchissement solaire au Maroc dans le cadre du projet PRSM (Procédés de Rafraîchissement Solaire au Maroc) financé par l'IRESEN (Institut de Recherche en Energie Solaire et Energies Nouvelles). L'objectif est d'étudier les facteurs concernant l'optimisation d'une machine à absorption solaire (LiBr-H2O) sous les conditions marocaines. De plus, un certain nombre de critères de conception, qui peuvent être utilisés par les concepteurs de systèmes de climatisation et de chauffage solaires, ont été établis en tenant compte de considérations énergétiques et économiques. En conséquence, cette thèse couvre quatre aspects. Le premier aspect présente un aperçu de recherche bibliographique sur les technologies solaires, en mettant l'accent sur les systèmes du froid solaire, les processus pertinents existants, l'état du marché, les développements récents des technologies les plus prometteuses et les principaux indicateurs de performance qui figurent dans la littérature. De plus, l'aspect expérimental de l'installation de climatisation solaire adopté dans le projet PRSM a été décrit pour identifier les caractéristiques techniques importantes de l'installation et les difficultés rencontrées lors de la réalisation du prototype. La deuxième dimension concerne la faisabilité technique d'un système de climatisation solaire en se basant sur des indicateurs énergétiques et économiques et prenant en compte les effets combinés des climats, des catégories de bâtiments et des besoins en climatisation dans les conditions marocaines. Le troisième aspect présente le stockage latent de l'énergie thermique utilisant les matériaux à changement de phase (MCPs). Il porte sur l'étude des méthodes numériques utilisées dans la modélisation des phénomènes de changement de phase et se concentre également sur l'ajout des MCPs dans le système de climatisation solaire intégré à l'intérieur du ballon solaire connecté au générateur de la machine à absorption pour évaluer l'amélioration possible du rendement du système. Le quatrième volet de cette thèse présente l'analyse technico-économique et de sensibilité appliquée au développement d'un procédé solaire combiné d'eau chaude sanitaire, chauffage et climatisation au Maroc. L'analyse globale via une généralisation des résultats au niveau national a été réalisée en complément d'une analyse de sensibilité liée à l'investissement dans ces systèmes afin d'évaluer le potentiel de remplacement des technologies traditionnelles par les systèmes solaires et les gains éventuels liés à leur implantation au Maroc. / This thesis reports the results of research into the modeling and simulation of a solar air-conditioning system for Morocco in the framework of the project SCPM (Solar Cooling Process in Morocco) funded by IRESEN (Research Institute for Solar Energy and New Energies). The aim is to investigate the factors concerning the optimization of a LiBr-H2O solar absorption chiller under Moroccan conditions. Further, a number of design criteria, which can be used by designers of solar cooling and heating systems, have been established using energy and economic considerations. Accordingly, this thesis covers four aspects. The first overviews the literature survey on solar technologies with a focus on solar cooling systems which reports the relevant processes, summarizes the market status, presents the recent developments of the most promising technologies and describes the main performance indicators figuring in the literature. Moreover, the experimental aspect of the solar air-conditioning installation adopted in the SCPM project was described to identify the important technical characteristics of the installation and the difficulties encountered during the realization of the prototype. The second dimension concerns the technical feasibility of solar air-conditioning system using energy and economic indicators taking into account the combined effects of climates, building categories and cooling demands under Moroccan conditions. The third aspect presents the latent thermal energy storage using Phase Change Materials (PCMs). It concerns the investigation of numerical methods used in the modeling of phase change phenomena and also focuses on PCMs addition in the solar cooling process integrated inside solar storage tank connected to the generator of the absorption chiller to evaluate the possible enhancement in the system efficiency. The fourth aspect of this thesis outlines the technico-economic and sensitivity analysis applied to the development of a combined processes of solar DHW, heating and air-conditioning in Morocco. The overall analysis via a generalization of the results to the national level was carried out in addition to a sensitivity analysis related to the investment in these systems in order to assess the potential of replacing traditional technologies with the solar systems and the possible earnings related to their implementation in Morocco.

Page generated in 0.0584 seconds