• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mise en évidence des corrélations à longue portée dans des systèmes chimiques hors d'équilibre par simulation microscopique

Dupont, Geneviève January 1988 (has links)
Doctorat en Sciences / info:eu-repo/semantics/nonPublished
2

Études théoriques des réactions monomoléculaires en phase gazeuse

St-Laurent, Pierre 30 January 2019 (has links)
La version quantique de la théorie de Marcus et Rice fut appliquée au calcul de la constante de vitesse de deuxième ordre et de 1'énergie critique des décompositions monomoléculaires à basse pression du chlorure de méthyle, du peroxyde d'hydrogène et du chlorure de nitrosyle; nous l'avons également appliquée au calcul de l'énergie d'activation de la décomposition de l'azomé- thane à basse pression. Le choix des degrés de liberté actifs, i.e. des degrés de liberté qui participent au transfert d'énergie intramoléculaire, a été basé sur des arguments raisonnés, ce qui nous a conduit à considérer toutes les vibrations et les rotations internes comme actives. Lorsque la molécule est du genre toupie symétrique, il faut également considérer une rotation externe comme active. Dans ce dernier cas, nous avons étudié l'effet de la conservation du moment angulaire total et un facteur de correction approprié a été incorporé dans la constante de vitesse calculée. La constante de vitesse théorique a également été corrigée pour tenir compte de 1'anharmonicité des vibrations moléculaires. Nous avons comparé les méthodes de Haarhoff et des polynômes généralisés de Bernoulli pour le calcul de la densité des niveaux énergétiques. Pour les trois molécules, CH^Cl, HgCL et N0C1, les résultats obtenus sont en bon accord avec les résultats expérimentaux et l'effet de 1'anharmonicité a été trouvée minime. Reste à vérifier expérimentalement la valeur obtenue pour 1'énergie d'activation de la décomposition de 1'azométhane à basse pression. / Montréal Trigonix inc. 2018
3

Impact of physicochemical properties of filtration membranes on peptide migration and selectivity during electrodialysis with filtration membranes : development of predictive statistical models and understanding of mechanisms involved

Kadel, Sabita 19 January 2021 (has links)
Au cours du procédé d'électrodialyse avec membrane de filtration (EDMF), les peptides chargés migrent sélectivement à travers des membranes de filtration (MFs) dans les compartiments respectifs de récupération des peptides anioniques (ARC) ou cationiques (C+ RC). Par conséquent, le type d'interaction entre les peptides et l'interface de la MF, en raison de ses propriétés physicochimiques, doit avoir un impact significatif sur la performance globale de l’EDMF (migration et sélectivité des peptides). Donc, l'objectif principal de cette thèse de doctorat était d'étudier les propriétés physicochimiques principales des MFs qui contribuent aux interactions interfaciales peptide-membrane facilitant ou entravant la migration globale et la séparation sélective des peptides pendant l’EDMF, et de comprendre les mécanismes impliqués dans ces interactions. Ainsi, dans cette étude, 16 MFs, caractérisées en termes de propriétés physicochimiques (potentiel zêta, conductivité, nature hydrophile/hydrophobe de la surface et des pores, épaisseur, rugosité, porosité et pourcentage de distribution des macropores dans la couche filtrante), ont été testées lors de l'EDMF pour séparer simultanément les peptides anioniques et cationiques d'un hydrolysat de protéines de lactosérum complexe et bien caractérisé. Dans la première étude, 6 MFs, différentes en termes de matériau, ont été testées incluant une membrane d’ultrafiltration (polyéthersulfone (PES)) comme contrôle et cinq membranes de microfiltration (fluorure de polyvinylidène (PVDF) et chlorure de polyvinyle (PVC-silice, fonctionnalisée (sulfopropyle ou amine quaternaire) ou non)). Les analyses de redondance (RDA) et de régression multivariées ont démontré qu’au moins deux des quatre propriétés suivantes des MF avaient un impact significatif sur la migration de tout peptide chargé ; le potentiel zêta, l’hydrophilie de surface/des pores, la porosité et la rugosité. De plus, l'effet important de la taille des pores sur la sélectivité des peptides a également été rapportée dans cette étude. Enfin, des modèles statistiques prédictifs qui relient la migration des peptides avec les propriétés de MF significatives ont été proposés. Dans la deuxième étude, réalisée sur des membranes de PES avec une large gamme de seuils de coupure (MWCO) de (5 à 300 kDa), une relation linéaire a été observée entre le MWCO et la migration globale des peptides (MGP) pour les deux compartiments de récupération. iii Cependant, la migration sélective des peptides vers ARC ou C+ RC s'est révélée être influencée par le MWCO des MFs ainsi que par les propriétés physicochimiques (charge et poids moléculaire (PM)) des peptides ; la migration d'un peptide ayant un faible PM et une faible charge (positive ou négative) était favorisée lorsqu’une MF ayant un petit MWCO était utilisée, tandis que l’inverse se produisait pour un peptide ayant un PM élevé et une charge élevée. Dans la troisième étude, l'effet de la combinaison du matériau de la membrane (polyacrylonitrile (PAN), PES et PVDF) /MWCO (30 et 50 kDa) sur la migration et la sélectivité des peptides, a tout d’abord été étudié. Les effets simples du matériau membranaire et du MWCO sur la MGP vers C+ RC, de même que l'effet combiné des matériaux membranaires/MWCO sur la MGP vers ARC et la migration sélective des peptides vers les deux compartiments de récupération ont été observés. Deuxièmement, une RDA réalisée sur l’ensemble des données obtenues pour les MFs sélectives testées dans cette recherche doctorale, a démontré l'impact significatif du potentiel zêta, de la conductivité, de la rugosité et du pourcentage de distribution des macropores dans la couche filtrante des MFs sur la MGP. Concernant la migration sélective des peptides, en plus des propriétés des MFs susmentionnées, l'impact significatif de l'angle de contact a été démontré pour au moins la migration d’un peptide anionique et/ou cationique vers leurs compartiments de récupération respectifs. Ces propriétés significatives ont favorisé différentes interactions telles qu’électrostatique, exclusion de taille et hydrophile/hydrophobe entre l’interface de la MF et le peptide, ce qui a eu pour effet de, soit faciliter, soit inhiber la migration de ce peptide. Enfin, des modèles statistiques prédictifs globaux ont été développés pour la MGP et pour la migration de chaque peptide individuel vers ARC et/ou C+ RC en fonction des propriétés importantes de la MF utilisée. Ces modèles permettent ainsi l'estimation du comportement de migration de ces peptides lorsque les MFs, sur une large gamme de propriétés physicochimiques, sont utilisées en EDMF. Les résultats obtenus dans cette thèse ont démontré, pour la première fois, la corrélation significative entre les propriétés physicochimiques des MFs, et la migration et la sélectivité des peptides pendant l'EDMF. Cependant, les modèles prédictifs développés dans cette étude iv peuvent être utilisés pour la gamme de peptides et les propriétés physicochimiques des MFs testées. Par contre, les mécanismes et explications proposés dans cette étude, concernant les interactions MF/peptide, peuvent être généralisés afin de comprendre tous les types d'interactions peptide/membrane. Comme perspectives à ce travail, l’étude de différentes sources d'hydrolysats, d’autres MFs et d’un hydrolysat produit par d’autres enzymes permettra la validation de ces modèles statistiques et leur généralisation. / During electrodialysis with filtration membranes (EDFM), charged peptides selectively migrate through filtration membranes (FMs) to their respective anionic (ARC) or cationic (C + RC) peptide recovery compartments. Consequently, the type of interactions occurring between FM and peptide at the interface, due to their physicochemical properties, must have significant impact on overall EDFM performances (peptide migration and selectivity). Therefore, the main objective of this doctoral thesis was to investigate the major FM properties that contribute to peptide-membrane interactions at the interface, which either facilitates or hinders global migration and selective separation of peptides during EDFM, and to understand the mechanisms involved behind those interactions. Thus, in this study, 16 FMs, characterized in terms of their physicochemical properties (zeta potential, conductivity, hydrophilic/hydrophobic nature of the surface and pores, thickness, roughness, porosity and percentage of macropores distribution in filtrating layer) were tested during EDFM to simultaneously separate anionic and cationic peptides from a well-characterized complex whey protein hydrolysate. In the first study, 6 FMs were tested, differing in terms of membrane materials, including one ultrafiltration (polyethersulfone (PES)) as a control and 5 microfiltration ( one polyvinylidene fluoride (PVDF) and four polyvinyl chloride (PVC)-silica: two functionalized (sulfonyl or amino) or two non-functionalized). Redundancy analysis (RDA) and multivariate regression analysis demonstrated that at least two FM properties among zeta potential, pore/surface hydrophilicity, porosity and roughness significantly impacted the migration of any charged peptide. In addition, the important effect of pore size on peptide selectivity was also reported. Finally, predictive statistical models that link each peptide migration with significant FM properties were proposed. In the second study, which was carried out on PES membranes with a wide range of molecular weight cut-offs (MWCOs) (5 kDa to 300 kDa), a linear relation was noticed between MWCO and global peptide migration (GPM) to both recovery compartments. However, the selective peptide migration to A - RC or C + RC was found to be influenced by the vi MWCO of FMs as well as physicochemical properties (charge and molecular weight (MW)) of peptides. For instance, the migration of a peptide having low MW and low charge (positive or negative) was favored when a FM with small MWCO was used, while the opposite was observed for a peptide having high MW and high charge. In the third study, the effect of combination of membrane material (PAN, PES and PVDF)/MWCO (30 and 50 kDa) on peptide migration and selectivity was first studied. The simple effect of membrane material and MWCO on GPM to C+ RC was observed, while the combined effect of membrane materials/MWCO on GPM to A - RC and selective peptide migration to both recovery compartments was observed. Secondly, a RDA was performed on the data obtained for all the selective FMs tested in this doctoral research, which demonstrated the significant impact of zeta potential, conductivity, roughness and percentage of macropores distribution in the filtrating layer of FMs on GPM. Concerning selective peptide migration, in addition to the aforementioned FM properties, the significant impact of contact angle was noticed for at least one anionic and/or cationic peptide migration to their respective recovery compartments. These significant FM properties were found to trigger different interactions such as electrostatic, size exclusion and hydrophilic/hydrophobic between FM and peptide at the interface resulting in either facilitation or inhibition of peptide migration. Finally, global predictive statistical models were developed for GPM and each individual peptide migration to ARC and/or C+ RC based on these significant FM properties, which allow the estimation of their migration behavior when FMs having a wide range of physicochemical properties are used during EDFM. The results obtained in this Ph.D. thesis demonstrated, for the first time, the significant correlation between physicochemical properties of FMs, and peptide migration and selectivity during EDFM. The predictive models developed in this study can be used for the range of peptides and FMs tested. Moreover, the types of interactions occurring between FMs and peptide at the interface, and mechanisms and explanations proposed in this study can be applied to understand all types of peptide/membrane interactions. Validation of such models vii by using different sources of hydrolysates or different FMs or a hydrolysate produced by other enzymes will be the main perspectives of this research work.
4

Fingering of chemical fronts

De Wit, Anne 20 February 2004 (has links)
The present work aims at studying the coupling between hydrodynamic fingering instabilities and chemical reactions at the interface between two miscible solutions. Hydrodynamic deformations of interfaces between two reactive fluids as well as flows induced by chemical reactions at the front between two initially steady fluids are encountered frequently in combustion, petroleum, chemical and pharmaceutical engineering. Most of the time, concrete applications imply a very large number of variables so that an understanding of the fundamental processes of chemo-hydrodynamic coupling is out of reach. Our goal is here to analyze a much simpler model system in which only one mechanism of hydrodynamic instability is at play and for which the chemical reactions can be modeled by a one or two-variable model. <p><p>Buoyantly unstable, autocatalytic chemical fronts, are one such model system, which can be used as prototype to study the effects of the coupling between chemical reactions and hydrodynamic fingering instabilities. Fingering processes occur whenever a fluid of high mobility displaces a less mobile one in a porous medium. The initially planar interface looses then stability and a cellular fingering deformation of the interface is observed. Such an instability has been observed, for instance, in the iodate-arsenous acid and chlorite-tetrathionate reactions, autocatalytic redox reactions known to produce a change of density across a traveling front. Fingering happens there when the heavier solution lies on top of the lighter one in the gravity field. <p> <p>Our theoretical contribution to the analysis of fingering of chemical fronts focuses on different points which we detail in this thesis along the following outline. In chapter 2, we introduce fingering phenomena occurring in porous media and distinguish the situation of viscous and density fingering of pure non reactive fluids. Chapter 3 reviews the literature on coupling between fingering and chemical reactions before studying the linear stability conditions as well as nonlinear dynamics of density fingering of isothermal iodate-arsenous acid fronts. This prototype nonlinear redox reaction is the first one on which experimental results on fingering in spatially extended set-ups have been obtained. We next analyze in chapter 4 the density fingering of another front producing autocatalytic system i.e. the chlorite-tetrathionate reaction in order to address the influence of the chemical kinetics on the dynamics observed. The influence of the exothermicity of the reaction is then presented in chapter 5. Eventually, chapter 6 analyzes what happens if the kinetics is now bistable and further compares the situation of both viscous and density fingering of bistable fronts. We then conclude and present suggestions for future work in this subject at the frontier between nonlinear chemistry, hydrodynamics and engineering. <p> / Agrégation de l'enseignement supérieur, Orientation sciences / info:eu-repo/semantics/nonPublished

Page generated in 0.1123 seconds