• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 147
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 154
  • 154
  • 100
  • 95
  • 65
  • 65
  • 47
  • 36
  • 34
  • 32
  • 30
  • 29
  • 28
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Análise da qualidade de polimerização, por meio de testes de microdureza, de um cimento resinoso utilizado na cimentação de coroas totais em preparos com diferentes substratos / Analysis of quality of polymerization of a resin cement used to cement ceramic crowns in differents preparation substrates through microhardness tests

Luana Menezes de Mendonça 27 May 2011 (has links)
O objetivo deste estudo foi avaliar a microdureza do cimento resinoso Variolink II ( Ivoclar Vivadent, Schaan, Liechtenstein) empregado na cimentação de coroas totais de cerâmica (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) em preparos com 3 substratos (dentina, metal e resina composta). Foram utilizados 30 molares distribuídos em 3 grupos de acordo com o tipo de substrato. No grupo com substrato em dentina (D), as coroas foram cimentadas em dentes preparados em dentina. Nos grupos com substrato em metal (M) e resina (R), as coroas foram seccionadas no nível da junção cemento-esmalte e restauradas com núcleos metálicos e de preenchimento em resina composta, respectivamente. Cada um dos grupos foi subdividido em subgrupos para avaliação após 7 dias e 3 meses de armazenamento em água deionizada. Os espécimes foram seccionados no centro das coroas, no sentido vestíbulo-lingual e as superfícies foram polidas para a realização dos testes de microdureza ao longo da linha de cimento. Os valores de microdureza foram obtidos nos terços cervical, médio, oclusal das faces vestibular e lingual e na face oclusal. Os resultados foram submetidos a uma análise estatística prévia ANOVA a 3 critérios (substratos/ armazenamento/ terços e face oclusal), a qual não mostrou diferenças significativas entre os terços e face oclusal nos 2 períodos de armazenamento. Em seguida foi realizada a ANOVA a 2 critérios (substrato e armazenamento) e o teste de Tukey que mostraram os resultados do substrato em resina estatisticamente inferiores aos de dentina e metal, após o período de armazenamento de 7 dias. Conclui-se que a microdureza do cimento resinoso não variou nos diferentes terços e face e que a influência do substrato em resina no cimento foi tempo-dependente. / The aim of this study was to evaluate the microhardness of resin cement Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein) used to cement full ceramic crowns (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) in three preparations substrates (dentin, metal and composite resin). Thirty molars were divided into three groups, according to the type of the substrate. In the dentin substrate group (D), the crowns were prepared in dentin; the metal (M) and resin (R) substrates groups, the crowns were sectioned at cement enamel junction level and restored with metal cast post and composite resin filler, respectively. Each group was subdivided into subgroups to evaluation after 7 days and 3 months of storage in deionized water. After cementing the specimens were sectioned buccolingually at the center of the crowns, and the surfaces were polished to microhardness test along the cement line. The microhardness values were obtained in the cervical, medium and occlusion thirds of the buccal and lingual surfaces and in the occlusal surface. The results were submitted to a three-way ANOVA (substrates / storage / thirds and occlusal surface) to a prior statistical analysis and did not show significant differences between the occlusal surface and thirds in the two storage periods. Then two-way ANOVA (substrate and storage) and the Tukey test were performed. The results in the resin group were statistically lower than those of dentin and metal, after 7 days of storage. Therefore, the microhardness of resin cement did not change in the different thirds and face and that the influence of the resin substrate was time-dependent.
72

Avaliação de tratamentos de superfície na união de cimento resinoso ao titânio comercialmente puro

Almeida Junior, Antonio Alves de [UNESP] 26 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-26Bitstream added on 2014-06-13T20:18:31Z : No. of bitstreams: 1 almeidajunior_aa_me_arafo.pdf: 459545 bytes, checksum: df0008777c6ad28ca07cacdc0ed332ac (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este estudo avaliou a resistência ao cisalhamento da união entre o titânio comercialmente puro fundido e o cimento resinoso não-adesivo (RelyX ARC – 3M ESPE) após diferentes tratamentos na superfície metálica. Noventa discos de titânio comercialmente puro foram divididos aleatoriamente em nove grupos, os quais receberam um dos seguintes tratamentos, antes da aplicação do RelyX ARC: (n=10): 01) Al2O3 (50 μm); 02) Al2O3 (50 μm) + adesivo; 03) Al2O3 (50 μm) + silano; 04) Cojet Sand (30 μm); 05) Cojet Sand + adesivo; 06) Cojet Sand + silano; 07) Al2O3 (50 μm) + Rocatec (110 μm); 08) Al2O3 (50 μm) + Rocatec + adesivo; 09) Al2O3 (50 μm) + Rocatec + silano. Os espécimes foram termociclados (5.000 ciclos - 5 – 55 oC - 30 segundos de imersão) e então submetidos ao ensaio de cisalhamento As médias de resistência ao cisalhamento da união dos grupos de 1 a 9 foram respectivamente: 4,10 ± 0,79CD; 6,14 ± 0,99B; 4,34 ± 0,71CD; 2,58 ± 0,37EF; 2,31 ± 0,23 F; 5,70 ± 0,93B; 3,65 ± 0,70DE; 5,25 ± 1,08BC e 8,36 ± 1,63A. O teste t de Student apontou igualdade estatística entre os grupos jateados com partículas de Al2O3 e com partículas revestidas por sílica (P=0,630). A análise de 22 variância (ANOVA) a dois critérios seguida pelo teste de Tukey indicaram que: 1) o Rocatec apresentou resistência significativamente maior que o Cojet Sand (P<0,05); 2) o jateamento com partículas de óxido de alumínio apresentou resistência significativamente maior quando associado ao adesivo (P<0,001) enquanto o silano foi o melhor tratamento pós jateamento para as partículas revestidas por sílica (P<0,001) e 3) O jateamento com Rocatec seguido da aplicação do silano proporcionou a maior resistência ao cisalhamento de união entre o titânio comercialmente puro e o RelyX ARC. Todos os grupos apresentaram falha 100% adesiva. / This study evaluated the shear bond strength of a conventional resin cement (RelyX ARC – 3M ESPE) to cast commercially pure titanium (cp Ti) after different treatments on metal surface. Ninety cp Ti disks were randomly divided into 9 groups which received one of the following treatments before the application of RelyX ARC: (n=10): 01) Al2O3 (50 μm); 02) Al2O3 (50 μm) + adhesive; 03) Al2O3 (50 μm) + silane; 04) Cojet Sand (30 μm); 05) Cojet Sand + adhesive; 06) Cojet Sand + silane; 07) Al2O3 (50 μm) + Rocatec (110 μm); 08) Al2O3 (50 μm) + Rocatec + adhesive; 09) Al2O3 (50 μm) + Rocatec + silane. All specimens were thermal cycled (5000 cycles, 5 - 55 oC – 30-second dwell time) before tested in shear mode. The mean bond strength values (Mpa) for all groups were, respectively: 4,10 ± 0,79CD; 6,14 ± 0,99B; 4,34 ± 0,71CD; 2,58 ± 0,37EF; 2,31 ± 0,23 F; 5,70 ± 0,93B; 3,65 ± 0,70DE; 5,25 ± 1,08BC e 8,36 ± 1,63A. The Student t test showed that there was no significant difference between Al2O3 particles and silica-modified Al2O3 particles (P=0.630). Two-way ANOVA and post hoc Tukey test (=.05) showed that: 1) Rocatec demonstrated significantly higher shear bond strength than Cojet Sand (P<0.05); 2) airborne-particle abrasion with Al2O3 particles exhibited the highest shear bond strength with adhesive (P<0.001) while silica-modified Al2O3 particles exhibited the best behavior when associated with silane (P<0.001); 3) Rocatec plus silane provided the highest shear bond strength between cp Ti and RelyX ARC. All groups showed 100% adhesive failure.
73

Anatomização de pinos de fibra de vidro: estudo de propriedades mecânicas na interface restauradora adesiva

Godas, André Gustavo de Lima [UNESP] 30 May 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-05-30Bitstream added on 2015-03-03T12:07:02Z : No. of bitstreams: 1 000795316.pdf: 2072279 bytes, checksum: 794bef0f7ff2ce86e28236f7c09f8722 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar as propriedades mecânicas (módulo de elasticidade e dureza Martens) do cimento resinoso e dentina subjacente à interface adesiva quando da cimentação de pinos anatomizados e avaliar a resistência de união entre pinos de fibra de vidro anatomizados aos diferentes terços da dentina intraradicular antes e após a ciclagem mecânica, através do teste push-out. Quarenta pré-molares unirradiculares foram submetidos ao tratamento endodôntico e divididos em quatro grupos (n=10) de acordo com o tipo de retentor intra-radicular utilizado (pinos de fibra de vidro anatomizados com resina composta e pinos de fibra de vidro sem anatomização) e envelhecimento (com ou sem ciclagem mecânica, em equipamento eletromecânico de ensaios de fadiga, totalizando 1.200.000 ciclos). As amostras foram seccionadas em cortadeira de precisão, obtendo uma fatia de aproximadamente 1,3mm de cada terço a ser analisado (cervical, médio e apical), sendo então submetidas às mensurações de dureza Martens, módulo de elasticidade e ao teste de resistência de união nos diferentes terços da raiz. Após o teste de resistência de união, as amostras foram avaliadas em microscopia eletrônica de varredura. Os dados de resistência de união (MPa) e propriedades mecânicas (GPa) foram submetidos à ANOVA dois fatores para análises repetidas, sendo considerados como fatores de estudo os grupos experimentais e as regiões analisadas. As médias foram comparadas com o teste de Tukey (p = 0.05). Baseado nos resultados obtidos e nas limitações do estudo, a anatomização dos pinos de fibra de vidro com resina composta pouco influenciou nas propriedades mecânicas do cimento resinoso e da dentina adjacente, e não contribuiu para melhoria da resistência de união, independente da ciclagem mecânica realizada. A anatomização... / The aim of this study was to evaluate the mechanical properties (elastic modulus and Martens hardness) of the resin cements and underlying dentin after the bonding of customized fiberglass posts to different thirds of intraroot dentin, as well as to measure the push-out bond strength before and after mechanical cycling. Single root pre-molars were subjected to endodontic treatments, and the samples were divided into four groups (n=10) according to the type of intraroot retainer used (customized and non-customized fiberglass posts) and aging (submitted or or not submitted to mechanical cycling, totaling 1.200.000 cycles). The roots were sectioned in slices of approximately 1.3mm (cervical, middle and apical regions) and submitted to the measurements of Martens hardness, elastic modulus and push-out bond strength test in different intrarradicular regions. After bonding strength test, the specimens were evaluate by scanning electron microscopy to characterize the dentin structure. Data of bond strength (MPa) and mechanical properties (GPa) were subjected to two-factor repeated measures ANOVA, considering the experimental groups and the regions analyzed as the factors of the study. Means were compared by Tukey's test (p = 0.05). Based on the results and limitations of the study, the customization of fiberglass posts with composite resin had few influence on the mechanical properties of resin cement and underlying dentin, and not contribute for the increase of push-out bond strength, independent of mechanical cycling procedure. The customization with composite resin would not be an essential clinical procedure to lute fiberglass posts to intrarradicular dentin. / FAPESP: 12/07212-0 / FAPESP: 12/09721-0
74

Estudo comparativo in vitro do efeito da ciclagem térmica sobre a resistência à tração de copings metálicos cimentados sobre dentes naturais, utilizando se de dois agentes cimentantes /

Silva, Eduardo Galera da. January 1997 (has links)
Orientador: João Vieira de Moraes / Banca: Celso -Ite Tanaka / Banca: Maria Amélia Maximo de Araújo / Resumo: O estudo avaliou a resistência ao teste de arrancamento de coroas totais metálicas (NiCrBe), cimentadas em dentes humanos naturais extraídos (terceiros molares), com preparos padronizados realizado num aparelho especialmente idealizado para tal, baseado no princípio do funcionamento do torno mecânico. As coroas foram cimentadas com cimento de fosfato de zinco e cimento adesivo de resina. O total da amostra foi de sessenta dentes e as respectivas coroas, divididas em trinta para o grupo controle e trinta para o grupo experimental. Para o grupo controle, imediatamente após as cimentações, os corpos de prova foram armazenados em água a 37ºC por 48h antes de serem submetidos ao teste de tração. Para o grupo experimental, anteriormente ao teste de arrancamento, os trinta corpos de prova foram submetidos à ciclagem térmica com variações de 6, 61 e 37ºC, num total de 8 mil ciclos. Os resultados mostraram para o grupo controle, coroas cimentadas com cimento de fosfato de zinco, uma resistência média de 32,33Kgf. Nas amostras cimentadas com Panavía 21 os dentes não resistiram à remoção das coroas dos respectivos preparos, ocorrendo fratura em 100% dos dentes. Para o grupo experimental, a resistência média oferecida ao teste de arrancamento pelas coroas cimentadas com cimento de fosfato de zinco foi de 27,63Kgf e para as cimentadas com Panavia Ex de 35,00Kgf. Em geral, os resultados mostraram uma diminuição da resistência à tração oferecida pelos agentes cimentantes, quando os corpos de prova foram submetidos previamente à cíclagem térmica. Surpreendentemente, houve uma grande variação em relação aos dados encontrados nos testes de tração, tanto para o cimento de fosfato de zinco como para o cimento de resina, sob as duas condições analisadas, sem e com ciclagem térmica / Abstract: This study evaluated the tensile bond strenght of complete metal crowns (Ni Cr Be) bonded to sound natural extracted teeth on which standardized preparations were carried out with a special designed device based on the lathe principie. Crowns were luted with zinc phosphate cement and a resin adhesive cement (Panavia 21 ). 60 extracted third molars were separated in two groups of 30, the first was used as a control group and the second as a test group. For the control group, after luting the crowns to the prepared teeth the specimens were immersed in water at 37ºC and stored for 48h before being submitted to the tensile bond strenght test. For the test group, after luting the crowns to the prepared teeth, specimens were thermocycled with temperatura changes of 6, 61 and 37ºC to 8.000 cycles. Results for the control groups showed that crowns luted with ZPC presented a mean tensile strenght of 32,33kgf. Teeth with crowns luted with the resin adhesive cement showed fractures for all the specimens. Results for the test groups showed that specimens luted with ZPC presented a mean tensile strenght of 27,63kgf and those with Panavia Ex, 35,00kgf. Overall results showed reduced strenght when specimens were thermocycled prior to the tests. Unexpected results were found for both cements under thermocycling or not. Several teeth fractures ocurred during the tests, for both groups luted with both cements / Mestre
75

Nanotubos de nitreto de boro como carga para resinas adesivas

Degrazia, Felipe Weidenbach January 2017 (has links)
O objetivo do presente estudo foi desenvolver e avaliar a incorporação de nanotubos de Nitreto de Boro (BNNT) como carga em uma resina adesiva. Foi formulada uma resina adesiva utilizando-se os seguintes reagentes: 2- hidróxietil metacrilato (HEMA), Bisfenol A glicol dimetacrilato (BisGMA), canforoquinona (CQ) e Etil 4-dimetilaminobenzoato (EDAB). Os BNNTs foram caracterizados por Microscopia Eletrônica de Varredura (MEV) e Microscopia Eletrônica de Transmissão (MET). O adesivo experimental com diferentes concentrações de BNNT (0, 0,05, 0,075, 0,1 e 0,15%) foi caracterizado quanto ao ângulo de contato e energia livre de superfície (ELS), dureza e amolecimento em solvente (solução de etanol) em microdurômetro, deposição mineral até 14 dias e grau de conversão por espectroscopia Raman e resistência coesiva. O adesivo experimental com diferentes concentrações de BNNT após imersão por 3 h em 65% HNO3 e 48 h em H2O2 foi caracterizado por grau de conversão e cinética de polimerização por Espectroscopia de infravermelho por transformada de Fourier (FTIR), ângulo de contato em dentina por tensiômetro, citotoxicidade por sulforodamina B (SRB) e resistência de união imediata e longitudinal Os resultados da análise de microscopia eletrônica de varredura e de transmissão demonstraram nanotubos de nitreto de boro com diâmetros de 5 a 10 nanometros com término fechado. Nenhuma modificação no grau de conversão ocorreu após a incorporação de BNNTs até 0,15%. Os ângulos de contato de água e α-bromonaftaleno aumentaram (p < 0,05) e consequentemente a ELS diminuiu após a incorporação de BNNTs ao adesivo. Houve aumento da microdureza e da resistência ao amolecimento em solvente após incorporação de 0,075, 0,1 e 0,15% de BNNTs. Não houve diferença significativa na resistência coesiva entre os diferentes grupos. Foi encontrada deposição mineral nos espécimes com BNNT após sete dias de imersão em SBF (fluido corporal simulado). Após o tratamento dos BNNTs com HNO3 e H2O2 e incorporação ao adesivo, houve aumento do grau de conversão e da taxa de polimerização máxima após incorporação de 0,075 e 0,1% de BNNT. O ângulo de contato à dentina aumentou após a incorporação de 0,15% BNNT. Não houve diferença significativa na resistência de união entre os grupos após 24 h (p >0,05). Após 6 meses a resistência de união diminuiu significativamente para o grupo 0% e 0,15% BNNT. Entretanto, os grupos que tiveram incorporação de BNNT obtiveram maiores valores que 0% (p <0,05). Não houve diferença no crescimento celular (p >0,05) entre os grupos em comparação ao grupo controle positivo (100% de crescimento). A incorporação de BNNT até 0,15% melhorou as propriedades físico-químicas do adesivo dentário, promoveu deposição mineral e aumentou a estabilidade longitudinal sem apresentar citotoxicidade a fibroblastos, fornecendo benefícios consideráveis frente aos materiais disponíveis no mercado. / The aim of this study was to develop and evaluate the incorporation of boron nitride nanotubes (BNNTs) into an adhesive resin. An adhesive resin was developed using the following reagents: 2-hydroxyethyl methacrylate (HEMA), bisphenol-A glycidyl dimethacrylate (BisGMA), camphorquinone (CQ) e ethyl 4- dimethylaminobenzoate (EDAB). BNNTs were characterized by Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). The experimental adhesive with different concentrations of BNNT (0, 0.05, 0.075, 0.1 e 0.15%) was characterized by contact angle and surface free energy (SFE), hardness and softening in solvent (ethanol solution) by microdurometer, mineral deposition up to 14 days and degree of conversion by Raman spectroscopy and ultimate tensile strength test. The experimental adhesive with different concentrations of BNNT after immersion for 3 h in 65% HNO3 and 48 h in H2O2 was characterized by degree of conversion and polymerization kinetics by Fourier Transform Infrared Spectroscopy (FTIR), contact angle in dentin by tensiometer, sulforhodamine B (SRB) cytotoxicity and immediate and longitudinal bond strength. The results of scanning and transmission electron microscopy showed boron nitride nanotubes with diameters of 5 to 10 nanometers with closed end tips No change in degree of conversion occurred after the incorporation of BNNTs up to 0.15%. The contact angles of water and α-bromonaphthalene increased (p <0.05) and consequently SFE decreased after the incorporation of BNNTs to adhesive. After incorporation of 0.075, 0.1 and 0.15% BNNTs an increase was shown in microhardness and resistance to softening in solvent. No significant difference in ultimate tensile strength was found among groups. Mineral deposition was found on BNNT specimens after seven days of immersion in SBF (simulated body fluid). After BNNTs´ treatment with HNO3 and H2O2 and incorporation into the adhesive, there was an increase in the degree of conversion and the maximum polymerization rate after incorporation of 0.075 and 0.1% of BNNT. Contact angle in dentin increased after incorporation of 0.15% BNNT. There was no significant difference in microtensile bond strength among groups after 24 h (p> 0.05). After 6 months the bond strength decreased significantly for 0% group and 0.15% BNNT. However, the groups that had BNNT incorporation obtained higher values than 0% (p <0.05). There was no difference in cell growth (p> 0.05) among groups compared to the positive control group (100% growth). The incorporation of BNNT up to 0.15% improved the physicochemical properties of dental adhesive, promoted mineral deposition and increased longitudinal stability with no cytotoxicity to fibroblasts, providing considerable benefits against dental materials available in the market.
76

Estudo comparativo in vitro do efeito da ciclagem térmica sobre a resistência à tração de copings metálicos cimentados sobre dentes naturais, utilizando se de dois agentes cimentantes

Silva, Eduardo Galera da [UNESP] 04 July 1997 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:56Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-07-04. Added 1 bitstream(s) on 2015-12-10T14:29:10Z : No. of bitstreams: 1 000036232.pdf: 5393745 bytes, checksum: 5800df9fc12d98721c44be829a24048b (MD5) / O estudo avaliou a resistência ao teste de arrancamento de coroas totais metálicas (NiCrBe), cimentadas em dentes humanos naturais extraídos (terceiros molares), com preparos padronizados realizado num aparelho especialmente idealizado para tal, baseado no princípio do funcionamento do torno mecânico. As coroas foram cimentadas com cimento de fosfato de zinco e cimento adesivo de resina. O total da amostra foi de sessenta dentes e as respectivas coroas, divididas em trinta para o grupo controle e trinta para o grupo experimental. Para o grupo controle, imediatamente após as cimentações, os corpos de prova foram armazenados em água a 37ºC por 48h antes de serem submetidos ao teste de tração. Para o grupo experimental, anteriormente ao teste de arrancamento, os trinta corpos de prova foram submetidos à ciclagem térmica com variações de 6, 61 e 37ºC, num total de 8 mil ciclos. Os resultados mostraram para o grupo controle, coroas cimentadas com cimento de fosfato de zinco, uma resistência média de 32,33Kgf. Nas amostras cimentadas com Panavía 21 os dentes não resistiram à remoção das coroas dos respectivos preparos, ocorrendo fratura em 100% dos dentes. Para o grupo experimental, a resistência média oferecida ao teste de arrancamento pelas coroas cimentadas com cimento de fosfato de zinco foi de 27,63Kgf e para as cimentadas com Panavia Ex de 35,00Kgf. Em geral, os resultados mostraram uma diminuição da resistência à tração oferecida pelos agentes cimentantes, quando os corpos de prova foram submetidos previamente à cíclagem térmica. Surpreendentemente, houve uma grande variação em relação aos dados encontrados nos testes de tração, tanto para o cimento de fosfato de zinco como para o cimento de resina, sob as duas condições analisadas, sem e com ciclagem térmica / This study evaluated the tensile bond strenght of complete metal crowns (Ni Cr Be) bonded to sound natural extracted teeth on which standardized preparations were carried out with a special designed device based on the lathe principie. Crowns were luted with zinc phosphate cement and a resin adhesive cement (Panavia 21 ). 60 extracted third molars were separated in two groups of 30, the first was used as a control group and the second as a test group. For the control group, after luting the crowns to the prepared teeth the specimens were immersed in water at 37ºC and stored for 48h before being submitted to the tensile bond strenght test. For the test group, after luting the crowns to the prepared teeth, specimens were thermocycled with temperatura changes of 6, 61 and 37ºC to 8.000 cycles. Results for the control groups showed that crowns luted with ZPC presented a mean tensile strenght of 32,33kgf. Teeth with crowns luted with the resin adhesive cement showed fractures for all the specimens. Results for the test groups showed that specimens luted with ZPC presented a mean tensile strenght of 27,63kgf and those with Panavia Ex, 35,00kgf. Overall results showed reduced strenght when specimens were thermocycled prior to the tests. Unexpected results were found for both cements under thermocycling or not. Several teeth fractures ocurred during the tests, for both groups luted with both cements
77

Análise do comportamento da cor de restaurações cerâmicas sem metal avaliadas por diferentes métodos: estudo clínico prospectivo

Martini, Ana Paula [UNESP] 08 September 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-09-08. Added 1 bitstream(s) on 2016-02-05T18:34:24Z : No. of bitstreams: 1 000857916.pdf: 3361545 bytes, checksum: 05e359e822d36e17b2cdd2f6036cc13f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: O processo de interpretação da cor em restaurações cerâmicas delgadas pré e pós-tratamento é um desafio. Os métodos de avaliação dos resultados são diversos e a literatura não é clara em apontar o mais eficaz e eficiente. A questão é ainda mais relevante diante da variação do cimento resinoso utilizado. Proposição: Após variar o tipo de cimento resinoso utilizado, o objetivo deste estudo foi avaliar o comportamento da cor de restaurações cerâmicas em dentes com demanda estética, ao longo de 1 ano após o tratamento, com o auxílio de diferentes métodos de acompanhamento (espectrofotômetro, fotografias, vídeos e avaliação clínica) em um estudo clínico longitudinal e prospectivo. Materiais e Métodos: Foram selecionados 28 pacientes, perfazendo um total de 204 dentes restaurados (89 facetas laminadas, 57 coroas totais ou parciais e 58 lentes de contato). 76 restaurações foram cimentadas com Rely X veneer, 71 com Variolink veneer e 57 com Rely X U200. Foram realizadas mensurações de cor com espectrofotômetro, fotografias digitais e vídeos gravados no decorrer do tratamento e em controles periódicos (inicial, 30 dias, 180 dias e 1 ano após a cimentação). Grupos formados por observadores externos (pacientes, alunos de 1º e último ano de graduação, pós-graduandos e especialistas) avaliaram, aleatoriamente, as imagens obtidas inicialmente e ao final do tratamento, segundo perguntas sobre a satisfação ou não com o resultado estético do caso. Resultados: Os dados obtidos com o espectrofotômetro foram submetidos a testes estatísticos que revelaram diferença significativa apenas entre os tempos avaliados, contudo, para todos os tipos de restauração foi observada estabilidade de cor após, no máximo, 180 dias da cimentação. Não houve diferença estatística entre a satisfação dos diferentes grupos... / Introduction: The process of interpretation of color in thin ceramic restorations pre- and post-treatment is challenging. The evaluation methods of the results are diverse and literature is not clear in pointing out the most effective method. The question is even more relevant given the variation of the resin cement used. Purpose: After changing the type of resin cement used, the aim of this study was to evaluate the color behavior of ceramic restorations in teeth with aesthetic demand, over 1 year after treatment, with the help of different monitoring methods (spectrophotometer, photographs, videos and clinical assessment) in a longitudinal and prospective study. Materials and Methods: 28 patients were selected, for a total of 204 restored teeth (89 veneers, 57 crowns and 58 contact lenses). 76 restorations were cemented with Rely X veneer, 71 with Variolink veneer and 57 with Rely X U200. Color measurements were made with a spectrophotometer, digital photos and videos taken during treatment and periodic controls (initial, 30 days, 180 days and 1 year after cementation). Groups formed by outside observers (patients, students of 1st and last year of undergraduate, graduate students, and experts) evaluated, randomly, images obtained initially and after treatment, according to questions on satisfaction or not with the aesthetic outcome of the case. Results: The data obtained with the spectrophotometer were subjected to statistical tests which showed a significant difference only between the time periods; however, for all types of restoration, color stability was observed after a maximum of 180 days after cementation. There was no statistical difference between the satisfaction of different groups of outsiders observers with the aesthetic result of the cases for both the photos and for videos, although they videos have obtained the highest... / FAPESP: 12/14574-6
78

Análise da interface adesiva entre pinos de fibra de vidro e dentina intrarradicular submetida à irrigação com diferentes agentes condicionantes

Suzuki, Thaís Yumi Umeda [UNESP] 02 September 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-09-02. Added 1 bitstream(s) on 2016-02-05T18:34:25Z : No. of bitstreams: 1 000858044.pdf: 2235290 bytes, checksum: 51b5ad1697c21ed4ef39b0820eb09e2b (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito deste estudo foi avaliar a interação das soluções irrigantes e tipos de cimentos resinosos na cimentação de pinos de fibra de vidro nos diferentes terços da dentina intrarradicular, através do teste de resistência de união, avaliação das propriedades mecânicas e capacidade de selamento da interface adesiva. Noventa dentes pré-molares humanos unirradiculares foram utilizados neste estudo. Após obturação endodôntica e preparo mecânico dos condutos radiculares, os dentes foram divididos em 5 grupos de acordo com os agentes condicionantes (água destilada, hipoclorito de sódio 5,25%, ácido poliacrílico 25%, clorexidina 2%, dispersão de nanopartículas de prata à 23 ppm) e subdivididos em 3 grupos experimentais (n=6), de acordo com a técnica adesiva adotada para cimentação de pinos de fibra de vidro: Grupo SBU: adesivo autocondicionante ScotchbondTM Universal + cimento resinoso convencional RelyX ARC; Grupo U200: cimento resinoso autoadesivo RelyX U200; Grupo MCE: cimento resinoso autoadesivo Maxcem Elite. As propriedades mecânicas de dureza e módulo de elasticidade das estruturas da interface adesiva (cimento resinoso e dentina subjacente) foram mensuradas em ultramicrodurômetro digital DUH-211 (Shimadzu), sob carga de 5mN nos diferentes terços da dentina intrarradicular (cervical, médio e apical). A resistência de união foi mensurada pelo teste de push-out em máquina de ensaio universal (Emic DL 3000). A capacidade de selamento foi quantificada através de um sistema de infiltração de fluido (Flodec) durante 5 minutos. Os dados de resistência de união, propriedades mecânicas e capacidade de selamento foram submetidos a testes estatísticos de normalidade e analisados pela ANOVA para medidas repetidas e teste de Fisher (α = 0,05). Os resultados mostraram que as propriedades mecânicas de dureza... / The purpose of this study was to evaluate the interaction of conditioning agents and resin cements in the luting procedure of glass fiber posts in different thirds of intra-root dentin, through the bond strength test, mechanical properties and sealing ability of the adhesive interface. Ninety single-rooted premolares human teeth were used in this study. After endodontic filling and mechanical preparation of root canal, teeth were divided into five groups according to the conditioning agents (distilled water, 5.25% sodium hypochlorite, 25% polyacrylic acid, 2% chlorhexidine and 23 ppm silver nanoparticles dispersion). Three adhesive cementation technique were adopted: Group 1: ScotchbondTM Universal self-etching adhesive + RelyX ARC resin cement, Group 2: RelyX U200 self-adhesive resin cement, Group 3: Maxcem Elite self-adhesive resin cement. The mechanical properties (Martens hardness and elastic modulus) of the adhesive interface structures (resin cement and underlying dentin) were measured in a DUH-211 digital ultra-microhardness tester (Shimadzu), under load of 5mN in different areas of intra-root dentin (cervical, middle and apical). Push-out bond strength was measured in a universal testing machine (Emic DL 3000). Sealing ability was quantified with a fluid-filtration system (Flodec) during 5 min was immediately measured. The data of bond strength and mechanical properties were subjected to statistical tests of normality and analyzed by ANOVA for repeated measures and Fisher's test (α=0.05). The results showed that the mechanical properties of Martens hardness and elastic modulus of resin cements and the underlying dentine can be influenced by conditioning agents, as well as the depth of intraradicular dentin. The same phenomenon was observed in the push-out bond strength test. The 23ppm silver nanoparticle dispersion... / FAPESP: 12/12771-9
79

Resistência de união de cimentos resinosos, convencional e autoadesivo, em substratos dentinários normal e hipermineralizado artificalmente / Bond strength of resin, conventional and self-adhesive cements, under normal dentin substrates and sclerotic artificially

Tavares, Maria Tereza Gomes [UNESP] 21 March 2016 (has links)
Submitted by MARIA TEREZA GOMES TAVARES null (mariatereza_t@hotmail.com) on 2016-04-04T12:44:42Z No. of bitstreams: 1 Dissertação Maria Tereza.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-04-05T18:59:26Z (GMT) No. of bitstreams: 1 tavares_mtg_me_arafo.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) / Made available in DSpace on 2016-04-05T18:59:27Z (GMT). No. of bitstreams: 1 tavares_mtg_me_arafo.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) Previous issue date: 2016-03-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a resistência de união de cimentos resinosos, convencional e autoadesivo, em um substrato dentinário normal e hipermineralizado artificialmente. Sessenta e seis (N=67) molares humanos hígidos, doados pelo Banco de Dentes da Faculdade de Odontologia de Araraquara, foram selecionados e divididos aleatoriamente, de acordo com o tipo de substrato dentinário: normal (n= 33) e hipermineralizado artificialmente (n=34). Em seguida o grupo de substrato dentinário normal foi subdividido em N-ARC, N-U200 e N-AC+U200 de acordo com o tipo de protocolo de cimentação: RelyX™ ARC, RelyX™ U200 e condicionamento adicional com ácido fosfórico 37% por 15” + RelyX™ U200; e o de substrato hipermineralizado artificialmente foi subdividido em H-ARC, H-U200 e H-AC+U200 seguindo o mesmo protocolo de cimentação. Um (n=1) espécime de cada grupo foi submetido a análise de microscopia eletrônica de varredura (MEV). As cimentações dos cilindros foram realizadas com a ajuda de uma matriz bipartida de teflon. Após período de armazenagem em ambiente úmido por 24 horas a 37°C, os espécimes foram adaptados a um dispositivo para o teste de resistência de união ao microcisalhamento. A análise estatística utilizada foi Two-way ANOVA/Tukey. Não foram encontradas diferença estatística entre os substratos dentinários e os protocolos de cimentação. O cimento resinoso RelyX ARC apresentou maiores valores de resistência de união (N-ARC=77,60 e H-ARC=68,40), independente do substrato. O padrão de fratura predominante foi do tipo adesiva. As imagens de microscopia mostraram que os cimento autoadesivo RelyX U200 é incapaz de formar camada híbrida. Conclui-se que o cimento autoadesivo apresenta resistência de união ao microcisalhamento semelhante ao cimento convencional, independente do substrato dentinário ser normal ou hipermineralizado artificialmente. / The objective of this study was to evaluate the bond strength of resin, conventional and self-adhesive cements, in a normal dentin and sclerotic artificially. Sixty-six (N = 66) human molars, donated by Teeth Bank of Araraquara Dental School, were selected and randomly divided according to the type of dentin: normal (n = 33) and sclerotic artificially (n = 33). Then normal dentin group was subdivided into N ARC, N-U200 and N-AC + U200 in accordance with the type of cementing protocol: RelyX ™ ARC RelyX ™ U200 and additional conditioning with phosphoric acid 37% by 15 "+ RelyX ™ U200; and the sclerotic substrate was artificially subdivided into M-ARC M-H U200 and U200 AC + following the same protocol cementing. A (n = 1) specimen from each group was subjected to analysis of scanning electron microscopy (SEM). The cementing was carried out with the aid of a metallic mold Teflon. After the storage period in a humid environment for 24 hours at 37 ° C, the specimens were adapted to a device for testing the bond strength of the microshear. The statistical analysis used was Two-way ANOVA / Tukey. There were no statistical difference between the dentinal substrates and cementation protocols. The resin cement RelyX ARC showed higher bond strength values (N = 77.60 ARC and ARC-H = 68.40), regardless of the substrate. The pattern of prevalent fracture was of adhesive type of cement and dentin. The microscopy images showed that the selfadhesive cement RelyX U200 is unable to form hybrid layer. It follows that the selfadhesive cement bond strength has to microshear similar to conventional cement, independent of the substrate normal or sclerotic dentin be artificially.
80

Avaliação da dureza superficial de cimentos resinosos após cimentação de pinos de fibra de vidro: efeito de profundidade de polimerização e sistemas adesivos

Jardim, Patrícia dos Santos [UNESP] 06 April 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-04-06Bitstream added on 2014-06-13T19:01:42Z : No. of bitstreams: 1 jardim_ps_dr_arafo.pdf: 1044832 bytes, checksum: e4dd0c96ad60802f6b6357bc3b691056 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os pinos pré-fabricados de fibra de vidro têm sido o sistema de escolha para reconstrução de dentes anteriores tratados endodonticamente e o sucesso da cimentação dos pinos de fibra de vidro está associado à cimentação do tipo adesiva, sendo que o agente cimente normalmente utilizado é um cimento resinoso de dupla polimerização, entretanto questiona-se a eficácia dos cimentos de dupla polimerização, principalmente nas regiões muito distantes da fonte de luz, bem como sua compatibilidade química com sistemas adesivos simplificados. O presente trabalho teve como objetivo avaliar a dureza superficial de cimentos resinosos, um quimicamente ativado (Bistite II DC) e um de dupla polimerização (Rely X) em função de diferentes profundidades de polimerização e sistemas adesivos; bem como, formação de camada híbrida quando da cimentação de pino de fibra de vidro no canal radicular de dentes bovinos. Foram utilizados 40 raízes bovinas, as quais foram tratadas endodonticamente e divididas aleatoriamente em 4 grupos de 10 raízes cada de acordo com o cimento resinoso e sistema adesivo utilizado para cimentação do pino de fibra de fivro: (GI) Bistite II DC; (GII) Rely X associado ao Scotchbond Multi-Uso Plus; (GIII) Rely X associado ao Single Bond; (GIV) Rely X associado ao One-Up Bond F. Após 24 horas da cimentação, as raízes foram seccionadas no sentido transversal em três discos radiculares, representando os terços cervical, médio e radicular, com profundidades respectivas de 3,0mm; 6,0mm e 9,0mm. Para realização das medidas de dureza, cada secção radicular foi dividida em quadrantes, nos quais foram realizadas três medidas: (M1) próximo à dentina radicular; (M2) região intermediária; (M3), próximo ao pino de fibra de vidro, cujos resultados foram submetidos à Análise de Variância e Teste de Tukey. Após o Ensaio de Dureza, as amostras foram... . / Fiber posts have been the system of choice for endodontically-treated anterior teeth reconstruction, and the cementation luting success is associated to adhesive-type cementation, being the dual-cure resin cements the most utilized cement. However, the dual-cured cements efficacy is questioned, mainly in the regions distant from the light-cure source, as well as the chemical compatibility to simplified adhesive systems. The aim of the present study was evaluate superficial roughness of resin cements, being one of them chemically activated (Bistite II DC) and the other dual-cured resin cement (Rely X) under different light-cure depths and bond systems; as well as hybrid layer formation in cases of glass fiber post in bovine radicular canal. Forty bovine roots samples were used. These roots were endodontically treated and randomly separated in four groups of 10 roots each according to the resin cement and adhesive system used for glass fiber post cementation.: The groups were divided as follows: (GI) Bistite II DC; (GII) Rely X associated to Scotchbond Multi-Purpose Plus; (GIII) Rely X associated to Single Bond; (GIV) Rely X associated to One-Up Bond F. After 24 hours passed from cementation, roots were sectioned in transversal orientation in three radicular discs, representing the cervical, medium and radicular thirds, with respective depths of 3,0mm; 6,0mm e 9,0mm. For hardness measuring, each radicular section was divided in quadrants. These quadrants were measured three times: (M1) near radicular dentin; (M2) intermediary region; (M3), near glass fiber post. These results were submitted to ANOVA and Tukey Test. After hardness assay samples were submitted to hybrid layer evaluation in Scanning Electron Microscopy and subsequent photomicrography descriptive analysis. From the methodology and... (Complete abstract, click electronic address below).

Page generated in 0.4855 seconds