• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 874
  • 51
  • 51
  • 51
  • 50
  • 39
  • 8
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 2
  • 1
  • Tagged with
  • 889
  • 425
  • 367
  • 327
  • 266
  • 195
  • 182
  • 176
  • 169
  • 162
  • 146
  • 137
  • 129
  • 126
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Comparação da infiltração marginal de restaurações adesivas empregando instrumento rotativo ou um sistema químico-mecânico na remoção do tecido cariado /

Naressi, Suely Carvalho Mutti. January 1999 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Luis André Freire Pimenta / Banca: Silvio José Mauro / Banca: Newton José Giachetti / Banca: José Roberto Rodrigues / Resumo: Considerando a validade da proposta de remoção químico-mecânica face às vantagens e indicações que o produto Carisolv apresenta e visando a realização de restaurações duradouras, esta pesquisa teve como objetivo comparar o selamento de restaurações adesivas após a remoção químico-mecânica da cárie com Carisolv (Medi Team) e com o método convencional empregando instrumentos rotatórios. Para tanto, foram utilizados sessenta dentes molares humanos cariados que após a remoção da cárie pelas duas técnicas, receberam restaurações com os materiais adesivos Vitremer (3m), Dyract (Dentsply DeTrey) e TPH Spectrum (Dentsply DeTrey). Foi empregada a metodologia para mícroinfiltração com o corante Rodamina B a 0,2% em todos os corpos de prova, que posteriormente foram seccionados em cortadeira especial e avaliados em estereomicroscópio óptico, atribuindo-se escores conforme o grau de microinfiltração observado. A análise estatística constou dos testes não paramétricos de Kruskaii-Wallis e Mann-Whitney cujos resultados evidenciaram que a infiltração marginal ocorreu na maioria das amostras avaliadas; que a diferença entre os escores apresentados pelos materiais não foi significante com a técnica convencional, porém foi significante quando o Carisolv foi empregado; que o Vitremer apresentou os mais altos valores de microinfiltração em ambas as técnicas e que a remoção do tecido cariado pelo método convencional ou químico-mecânico com Carisolv, não influenciou o desempenho selador dos materiais adesivos empregados / Abstract: The chemo-mechanical removal of carious tissue using Carisolv (MediTeam) presents several advantages and indications, when lasting adhesive fillings are expected. This research proposes to compare the sealing conditions of adhesive restorations placed on teeth submitted either to the chemo-mechanical method using Carisolv or to the traditional bur method of caries removal. Sixty decayed human molars received, after the removal of the carious tissue, adhesive fillings of Vitremer (3M), Dyract (Dentsply DeTrey) e TPH Spectrum (Dentsply DeTrey). The microleakage was observed using the 0,2% Rodamine B dye method in all the samples. The samples were sectioned and examined under optical stereomicroscopy. The statistical analysis using the Kruskall-Wallis and Mann-Whitney non-parametrics tests showed the existence of marginal leakage in most samples; the differences observed in the materials tested were not significant when the traditional method was used but a statistically significant difference existed when Carisolv was employed; the highest levels of microinfiltration occured with Vitremer and the sealing properties of the various adhesive materials were not influenced by the caries removal method applied / Doutor
142

Citotoxicidade, genotoxicidade e expressão gênica em células da polpa dental humana sensibilizadas por cimentos endodônticos /

Rabelo, Sylvia Bicalho. January 2012 (has links)
Orientador: Carlos Henrique Ribeiro Camargo / Banca: Claudio Antonio Talge Carvalho / Banca: Ana Paula Martins Gomes / Banca: Marcia Sampaio Campos / Banca: Cácio de Moura Netto / Resumo: O sucesso dos tratamentos endodônticos está relacionado ao correto diagnóstico das alterações pulpares, à qualidade do preparo biomecânico e da obturação dos canais radiculares, bem como à compatibilidade entre os cimentos obturadores com os tecidos adjacentes ao canal. Atualmente a busca de bom comportamento biológico destes cimentos se faz de extrema importância. O presente estudo teve como objetivo analisar a citotoxicidade e a genotoxicidade dos extratos de três cimentos endodônticos e seus efeitos sobre a expressão dos genes BMP2, ALP, RUNX2, BGLAP, OPN e DMP1 em células da polpa dental humana. Foram utilizadas células primárias de tecidos pulpares de terceiro molar com rizogênese incompleta. Cimentos endodônticos foram depositados em placas de 24 poços e armazenados a 37°C por 6 h; cada espécime foi colocado em contato com 2,7 ml de meio de cultura (DMEM-F12) e as amostras foram incubadas por 24 h, a 37°C. Extratos originais (1:1) de cada material foram diluídos em série até 1:32 e analisados quanto a citotoxicidade pelo ensaio de MTT. Após a obtenção de uma diluição que não fosse extremamente tóxica e não interferisse demasiadamente na replicação celular (subdose), foi realizado o teste de micronúcleo para avaliação da genotoxicidade dos materiais. A expressão dos genes foi verificada por RT-PCR em tempo real, em 6, 12 e 24 h. O RNA total foi isolado e retrotranscrito. Os testes de citotoxicidade indicaram que a sobrevivência celular foi afetada pelos extratos na seguinte ordem: EndoREZ > AH Plus > RoekoSeal ≥ MTA. O EndoREZ propiciou o maior número de micronúleos no ensaio de genotoxicidade. A quantificação relativa indicou que em 24 h, o AH Plus e o EndoREZ agiram de modo similar, aumentando a expressão da OPN e reduzindo a ALP; o RoekoSeal gerou expressão da OPN... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The success of endodontic therapy is related to the correct pulp and periapical alterations diagnosis; to the good biomechanical instrumentation and to the root canal sealing quality; to the compatibility between the endodontic sealers and the root canal surrounding tissues as well. Nowadays, the seeking for a sealer with good biological behavior is extremely important. The aim of this study was to analyze the cytotoxicity and the genotoxicity of three endodontic sealers and their effects on the expression of the genes BMP-2, ALP, RUNX2, BGLAP, SPP1 and DMP1 in human dental pulp cells. Primary cells from the 5th passage obtained from pulp tissue of third molar with incomplete rizogenesis were used in this study. Endodontic sealers were placed in 24 well plates and stored at 37°C for 6 hours. After that, each specimen was covered with 2.7 ml of cell culture media (DMEM-F12) and incubated afterwards at 37°C for 24 h. Original extracts (1:1) of each material were serially diluted up to 1:32 and the citotoxicity was analyzed by MTT assay. After obtaining extracts subdose, non very toxic or non interfering on cell replication, genotoxicity was evaluated by micronucleus test. The gene expression was accessed by Real Time RT-PCR, after extracts exposure of 6, 12 and 24 h. Total RNA was isolate and retrotranscribed. The citotoxicity test has showed that cell survival was affected in the following order: EndoREZ > AH Plus > Roeko Seal ≥ MTA. EndoREZ has caused the highest score in micronucleus assay. Relative quantification indicated that at 24 h, AH Plus and EndoREZ increased OPN and reduced ALP; RoekoSeal has caused decreasing OPN... (Complete abstract click electronic access below) / Doutor
143

Análise da resistência de união à dentina humana submetida ao condicionamento total sob pressão pulpar simulada e armazenamento em etanol 75% /

Holleben, Priscila. January 2013 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Co-orientador: Maria Filomena Rocha Lima Huhtala / Banca: Linda Wang / Banca: César Rogério Pucci / Resumo: A degradação hidrolítica da interface adesiva é o fator mais crítico na longevidade dos procedimentos restauradores. O objetivo deste estudo, in vitro, foi avaliar, por meio do teste de microtração, a resistência de união do sistema adesivo Scotchbond Universal (SU, 3M ESPE) à dentina humana, submetida à simulação da pressão pulpar e ao armazenamento em água deionizada ou etanol 75% por 1 dia, 10 dias e 30 dias. O sistema adesivo foi aplicado de acordo com a técnica do condicionamento total e sob a simulação de 0 ou 15 cm de H2O de pressão pulpar (durante todo o procedimento restaurador). Foram utilizados 60 terceiros molares humanos divididos em 4 grupos: G1) SU aplicado sem simulação da pressão pulpar (0 cm H2O) e armazenado em água deionizada; G2) SU aplicado sem simulação da pressão pulpar (0 cm H2O) e armazenado em etanol 75%; G3) SU aplicado com simulação da pressão pulpar (15 cm H2O) e armazenado em água deionizada; G4) SU aplicado com simulação da pressão pulpar (15 cm H2O) e armazenado em etanol 75%. Os espécimes foram restaurados com a resina composta Filtek Z350 XT (3M ESPE). Após 48 h em água deionizada a 37ºC, os espécimes foram seccionados para a obtenção de palitos com área adesiva de aproximadamente 1 mm2, que foram submetidos ao teste de microtração após mais 1 dia, 10 dias ou 30 dias de armazenamento em água deionizada ou etanol 75%. A variação da resistência de união foi analisada pelos testes estatísticos ANOVA 3-fatores e Tukey (5% de significância). Todas as variáveis experimentais - pressão pulpar (p=0,0007), meio de armazenamento (p=0,0006) e tempo (p=0,0033) - tiveram influência estatisticamente significante sobre a resistência adesiva (p<0,05). O grupo restaurado sem pressão pulpar e armazenado em água por 1 dia apresentou a maior média (35,26  4,63 A), que diferiu estatisticamente dos grupos restaurado... / Abstract: The hydrolytic degradation of adhesive interface is the most critical factor affecting the longevity of restorative procedures. The aim of this in vitro study was to evaluate the microtensile bond strength of Scotchbond Universal Adhesive (SU, 3M ESPE) to human dentin, submitted to simulated pulpal pressure and stored in either deionized water or 75% ethanol for 1 day, 10 days and 30 days. The adhesive system was applied according to the total-etch technique and under the simulation of either 0 or 15 cm of H2O pressure (during all the restorative procedure). Sixty human third molars were used and divided into 4 groups: G1) SU applied without pulpal pressure (0 cm H2O) and stored into deionized water; G2) SU applied without pulpal pressure (0 cm H2O) and stored into 75% ethanol; G3) SU applied with pulpal pressure (15 cm H2O) and stored into deionized water; G4) SU applied with pulpal pressure (15 cm H2O) and stored into 75% ethanol. The specimens were restored with Filtek Z350 XT composite resin (3M ESPE). After 48 h in deionized water at 37ºC, the specimens were sectioned into dentin-resin beams with 1 mm2 of bonding area, which were submitted to the microtensile bond strength test after 1 day, 10 days or 30 days of storage in either deionized water or 75% ethanol. The variation of bond strength was determined by using 3-way ANOVA and Tukey's test (5% level of significance) analyses. All experimental variables - pulpal pressure (p=0.0007), storage media (p=0.0006) and time (p=0.0033) - had a statistically significant influence on the bond strength (p<0.05). The group restored without pulpal pressure and stored in water for 1 day showed the highest mean (35.26  4.63 A). This group was significantly different from groups restored with pulpal pressure and stored in water for 30 days (25.21  4.80 B) and ethanol for 10 days (24.63  3.18 B) and 30 days (23.31  6.25 B). Therefore, the .... / Mestre
144

Avaliação biológica de materiais protetores do complexo dentino-pulpar /

Duque, Cristiane. January 2005 (has links)
Orientador: Josimeri Hebling / Banca: Beatriz Costa / Banca: Carlos Estrela / Banca: Denise Madalena Palomari Spolidorio / Banca: Elisa Maria Aparecida Giro / Resumo: O objetivo deste estudo in vivo foi avaliar a resposta do complexo dentino-pulpar após a aplicação de um cimento de ionômero de vidro modificado por resina, um cimento de hidróxido de cálcio e um extrato de proteínas extraídas da matriz dentinária solúvel em EDTA (ESDP - EDTA-soluble dentin proteins) em cavidades profundas preparadas em dentes de macacos. Dezoito cavidades de classe V profundas foram confeccionadas em pré-molares de quatro macacos-pregos. Nos grupos 1 e 2, as paredes axiais das cavidades foram forradas com ESDP e cimento de ionômero de vidro modificado por resina (Vitrebond - 3M ESPE), respectivamente. No grupo 3 (controle), foi aplicado um cimento de hidróxido de cálcio (Dycal - Dentsply). Em seguida, as cavidades foram restauradas com amálgama. Após seis meses, os animais foram sacrificados e os dentes foram preparados para avaliação microscópica. Cortes seriados de seis micrometros foram corados utilizando as técnicas de H/E, tricrômico de Masson e Brown & Brenn. Nenhuma resposta inflamatória foi observada para os grupos controle ou de materiais experimentais. Entretanto, em relação à deposição de dentina reacional, houve diferença entre os grupos, considerando a seguinte seqüência: ESDP (Grupo 1) > Hidróxido de cálcio (Grupo 3) > Cimento de ionômero de vidro (Grupo 2). Todos os materiais foram biocompatíveis quando aplicados em cavidades profundas. ESDP estimulou maior deposição de matriz de dentina reacional que os cimentos Vitrebond e Dycal. / Doutor
145

Avaliação in vitro da resistência adesiva ao cisalhamento entre a dentina bovina, cimentos resinosos e materiais restauradores indiretos, tratados ou não com jato de óxido de alumínio, ácido fluorídrico e silano /

Pagani, Clóvis. January 2001 (has links)
Banca: Maria Amélia Maximo de Araujo / Banca: José Eduardo Junho de Araujo / Banca: Michel Nicolau Youssef / Banca: Sizenando de Toledo Porto Neto / Banca: Maria Salete Machado Cândido / Resumo: Neste trabalho avaliamos in vitro a resistência adesiva aos testes de cisalhamento na dentina bovina, com as seguintes variáveis: cimentos resinosos Enforce e Panavia F; materiais restauradores Art Glass, IPS Empress 2 e Targis e o tratamento das superfícies destes materiais com jato de óxido de alumínio, ácido fluorídrico e silano, nos períodos de 24h e 30 dias. Foram utilizados 288 dentes bovinos hígidos de animais com três anos de idade, com os quais foram confeccionados os corpos-de-prova, em caixas de resina poliéster. Os testes foram executados em máquina de ensaios mecânicos lnstron, modelo 430, com célula de 500kg de carga e com velocidade da ponta de 0,5 mm/min. Os resultados obtidos em kgf foram transformados em MPa e analisados estatisticamente pelo ANOVA, teste de Tukey e Box-Whisker Plot. O material IPS Empress 2 tratado com jato de óxido de alumínio, ácido fluorídrico e silano, cimentado com Panavia F e estocado em água destilada a 37°C, durante trinta dias, quando submetido aos testes de resistência ao cisalhamento, mostrou os melhores resultados / Abstract: The purpose of this study was to evaluate in vitro the shear bond strenght to bovine dentin, during 24h and 30 days with the following variables: resin cements Enforce and Panavia F; aesthetics restorative materials Art Glass, IPS Empress 2 and Targis, with surface treatment with microetching with aluminium oxide, fluoridric acid and silane. Two hundred eighty eight sound bovine teeth from 3 years old animals constituted the samples after inclusion on polyester resin box. lnstron model 430 Universal Testing Machine, a crosshead speed 0,5 mm/min and load cells of 500 Kg, was used for shear bond strenght testing (MPa). The results were statistically analysed by ANOVA The best result was obtained with /PS Empress 2, microetched with aluminium oxide, fluoridric acid and silane, cemented with Panavia F and stored in distilled water, 3f'C during 30 days
146

Resistência a extrusão de retentores intra-radiculares de fibra de vidro avaliando : técnica de confecção e cimento resinoso /

Clavijo, Victor Grover Rene. January 2011 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: José Roberto Cury Saad / Banca: Fabio Luiz Camargo Villela Berbert / Banca: Hugo Henriques Alvim / Banca: Victor Humberto Orbegoso Flores / Resumo: Neste estudo avaliou-se a resistência ao cisalhamento por extrusão de pinos de fibra de vidro, reembasados ou não com compósito, cimentados com dois tipos de cimentos resinosos em dentina intra-radicular, avaliando os segmentos cervical, médio e apical. Selecionaram-se 40 incisivos bovinos com dimensões semelhantes, removendo a porção coronária, padronizando o comprimento das raízes em 14 mm. Após, incluiu-se as raízes em resina acrílica, realizando tratamento endodôntico e, então o preparo dos espaços para os pinos, dividindo- as, em seguida, aleatoriamente em quatro grupos com dez amostras cada. Os elementos do grupo 1 receberam retentores de fibra de vidro cimentados com cimento resinoso RelyX ARC, grupo 2 retentores de fibra de vidro cimentados com cimento resinoso RelyX U100, grupo 3 retentores de fibra de vidro reembasados com resina composta e cimentados com cimento resinoso RelyX ARC e grupo 4 retentores de fibra de vidro reembasados com resina composta e cimentados com cimento resinoso RelyX U100. Ao término dos procedimentos de cimentação, realizou-se a secção dos segmentos radiculares, submetendo, então, os corpos-de-prova ao teste push-out em máquina de ensaios universal, através de ponta ativa cilíndrica com 1 mm de diâmetro, à velocidade de 0,5 mm/min, até extrusão do retentor. Obteve-se os seguintes valores médios de resistência de união, em MPa: grupo 1, terços cervical = 6,22 ± 2,64(a), médio = 4,25 ± 2,01(a) e apical = 4,45± 2,81(a); grupo 2, terços cervical = 5,04 ± 2,34(a), médio = 3,06 ± 2,12(a) e apical = 3,26 ± 2,38(a). grupo 3, terços cervical = 11,85 ± 1,67(b), médio = 11,83 ± 3,84(b) e apical = 10,39 ± 2,44(b). grupo 4, terços cervical = 12,05 ± 1,14(b), médio = 11,98 ± 3,23(b) e apical = 10,96 ± 2,14(b). Submeteram-se os valores à análise de variância e ao teste de Tukey com nível de significância de 5% indicadas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the bond strength of fiber posts, relined or not with composite resin, luted with resinous cement to radicular dentin, evaluating cervical, median and apical root segments. Fourty bovine incisors, with similar dimensions, were selected and cut 16 mm from the apical limit. The roots were embedded in acrylic resin and the radicular canals were root treated and post space prepared with a depth of 9 mm. Samples were randomly assigned to two groups of ten roots each. Group 1 received glass fiber posts luted with dual-cure resin cement RelyX ARC in association with a bonding system. In Group 2 the same type of posts were relined with composite for further cementation with resin cement RelyX U100. In Group 3, glass fiber post were relined with composite and cemented with resin cement RelyX ARC and in Group 4 glass fiber posts were relined ith composite and cemented with resin cement RelyX U100. After cementation procedures roots were sectioned transversally and three sections, from cervical, medium and apical thirds were obtained. Push-out test was performed in a universal testing machine with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion. Collected data was statistically analyzed by two- way ANOVA and Tukey HSD test (p<0,05). The measured retention strengths for cervical, medium and apical thirds were: Group 1, cervical thirds = 6,22 ± 2,64(a), medium = 4,25 ± 2,01(a) e apical = 4,45± 2,81(a); group 2, cervical thirds = 5,04 ± 2,34(a), medium = 3,06 ± 2,12(a) and apical = 3,26 ± 2,38(a). Group 3, cervical thirds = 11,85 ± 1,67(b), medium = 11,83 ± 3,84(b) and apical = 10,39 ± 2,44(b). Group 4, cervical thirds = 12,05 ± 1,14(b), medium = 11,98 ± 3,23(b) and apical = 10,96 ± 2,14(b). Glass fiber composite relined posts presented statistically higher retention values in cervical, medium and apical thirds when compared... (Complete abstract click electronic access below) / Doutor
147

Tratamentos de superfície e aplicação de excitação ultrassônica em reparos de restauração de cimento de ionômero de vidro /

Azevedo, Elcilaine Rizzato. January 2012 (has links)
Orientador: Angela Cristina Cilense Zuanon / Banca: Karina Antunes Neves / Banca: Raphael Freitas de Souza / Banca: Cyneu Aguiar Pansani / Banca: Rita de Cassia Loiola Cordeiro / Resumo: Este estudo teve como objetivo investigar a resistência máxima à tração de reparos de restaurações de CIV, após diferentes protocolos de tratamento de superfície e aplicação US. Foram confeccionados 15 corpos de prova para cada grupo experimental, os quais passaram por termociclagem (500 ciclos, de 5ºC e 55ºC ± 2ºC) e tratamento de superfície previamente a confecção do reparo, conforme segue: G1 - sem tratamento; G2 - tratamento de superfície com fresa diamantada; G3 - abrasão à ar; G4 - ácido fosfórico à 35%; G5 - ácido poliacrílico à 11,5%; G6 - fresa diamantada e ácido fosfórico à 35%; G7 - fresa diamantada e ácido poliacrílico à 11,5%; G8 - abrasão à ar e ácido fosfórico à 35%; G9 - abrasão à ar e ácido poliacrílico à 11,5%. O reparo foi confeccionado com CIV pigmentado com rodamina, para facilitar sua distinção. A excitação ultrassônica foi aplicada durante 0, 15 ou 30s para cada grupo. Após 24h de armazenamento, os corpos de prova foram seccionados em espécimes em forma de palito, com 0,9 mm2 de área de união e submetidos ao ensaio mecânico de microtração. As superfícies fraturadas foram avaliadas em lupa estereoscópica e classificadas em coesiva, adesiva ou mista. Foi considerada como variável dependente a resistência máxima a tração, e independentes o tratamento de superfície e a aplicação de US. As condições de homogeneidade de variâncias e de normalidade dos erros experimentais foram comprovadas, respectivamente pelos testes de Levene e de Shapiro-Wilk, complementada por comparações múltiplas pelo teste de Tukey. Adotou-se o nível de significância de 5% para a tomada de decisões. Os maiores valores de resistência de união dos reparos de cimentos de ionômero de vidro foram obtidos com o tratamento de fresa diamantada e ácido fosfórico. A aplicação do US (30 s) favoreceu a resistência de união... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The study aimed to evaluate the effect of different surface treatment protocols and the ultrasonic excitation on the microtensile bond stregth of the glass ionomer restoration repaired. A total of 135 specimens was made using an increment technique and it was thermocycled (500 cycles between 5ºC and 55ºC ± 2ºC). The specimens were separated into 9 groups of 15, and each group then received a different surface treatment before the repair prepare: G1 control, without treatment; G2 diamond bur; G3 air abrasion; G4 35% fosforic acid; G5 11,5% poliacrilic acid; G6 diamond bur and 35% fosforic acid; G7 diamond bur and 11,5% poliacrilic acid; G8 air abrasion and 35% fosforic acid; G9 air abrasion and 11,5% poliacrilic acid. The repair was prepared with glass ionomer cement (Ketac Molar Easymix) colored with saturated rhodamine B (Fluka, Buchs, Switzerland) for its distinction. The samples were submitted to the ultrasonic excitation during 0, 15 and 30 seconds and, then stored in 37°C ±2°C water during 24 h. Rectangular bar specimens with a cross-sectional area of 0.9 mm² were prepared and then submitted to the microtensile test. The fracture surfaces were evaluated under stereomicroscope and classified as cohesive, adhesive or mixed. Microtensile strength values are shown in MPa. The dependent and independent variables were considered, respectively, ultimate tensile strength and the surface treatments and ultrasonic excitation. The effects of each surface treatment and ultrasonic excitation on the microtensile strength (MPa) were determined by ANOVA and Tukey tests. The highest values of bond strength of repair of glass ionomer cement were obtained with the treatment of diamond cutter and phosphoric acid. The application of the U.S. (30 s) enhanced the bond strength of repair of ionomer after the combination of mechanical treatment with polyacrylic... (Complete abstract click electronic access below) / Doutor
148

Avaliação "in vitro" da resistência de união de dois sistemas adesivos dentinários à dentina bovina antes e após a termociclagem: teste de cisalhamento e análise estereomicroscópia /

Amendola, Alessandra Buhler. January 1999 (has links)
Orientador: José Roberto Rodrigues / Banca: José Claudio Martins Segalla / Banca: Clovis Pagani / Resumo: O objetivo do presente estudo foi o de avaliar e comparar a efetividade da união de dois sistemas adesivos: Scotchbond Multi-Uso Plus (3M) e Etch & Prime 3.0 (Degussa) à dentina bovina antes e após a termociclagem, bem como o de avaliar o tipo de fratura ocorrido na interface dentina/material. Empregaram-se dentes bovinos, que tiveram a superfície vestibular desgastada com lixas de papel de granulação crescente para a exposição da dentina. Os espécimes foram divididos em dois grupos, nos quais aplicou-se os sistemas adesivos e, posteriormente, a resina composta Z100 (3M) por meio de uma matriz de teflon com 4mm de diâmetro. Estes grupos foram subdivididos em dois subgrupos (A e B). O subgrupo A foi submetido ao ensaio mecânico de cisalhamento após 24h e o subgrupo B recebeu a ciclagem térmica, que consistiu de quinhentos ciclos entre 5°C e 55°C, com duração de 30s em cada temperatura, para depois ser submetido ao teste de cisalhamento. O ensaio mecânico foi realizado em máquina lnstron Universal à velocidade de 0,5mm/min. As superfícies fraturadas foram analisadas em estereomicroscópio (Karl Zeiss). A aplicação do teste estatístico ANOVA, ao nível de significância de 0,05, revelou que os valores de resistência de união dos dois sistemas adesivos avaliados não apresentaram diferença estatisticamente significativa e que a utilização da termociclagem não influenciou a resistência adesiva dos materiais testados. O Scotchbond Multi-Uso Plus apresentou predominância de falhas adesivas e o Etch & Prime 3.0 apresentou maior quantidade de fraturas mistas, seguidas pelas fraturas adesivas / Abstract: The aim of fhe present study was to investigate the shear bond strength of two adhesive systems, Scotchbond Multi-Purpose Plus (3M) and Etch & Prime 3.0 (Degussa), to bovine dentin, before and after thermal cycling. Bovine incisors were embedded in self-cured resin and labial dentin surfaces were ground with sequential abrasive sandpapers. The specimens were separated into two groups to receive the adhesive systems. A composite resin cylinder (Z100-3M) was bonded to the dentinal surface. The two groups were divided into two more groups (A and B). The subgroup A was shear tested after 24h and the subgroup B was subjected to 500 thermal cycles, between 5ºC and 55ºC, with a dwell time of 30 seconds and, then, shear tested. The bond strength was performed on a Universal lnstron machine 4301, with a load cell of 500 Kg and a speed of 0,5mm/min. The mode of failure were classified. The analysis of variance (ANOVA), at 5% significant level, revealed that there were no significant differences among the bond strength of the two adhesive systems, and that the thermal cycling did not significantly influence strength of the two materials tested. The Scotchbond Multi-Purpose Plus showed a considerable number of adhesive failures and the Etch & Prime 3.0 showed predominantly mixed fractures, followed by adhesive fractures / Mestre
149

Discrepâncias de assentamento ocorrido em coroas totais metálicas, com e sem alívio interno, variando-se os términos cervicais e os agentes cimentantes /

Figueiredo, Aldari Raimundo January 1997 (has links)
Orientador: Marco Antonio Bottino / Banca: Pedro Tortamano Neto / Banca: Orlando Magalhães Filho / Banca: José Eduardo Junho de Araujo / Banca: Ruy Fonseca Brunetti / Resumo: Foi feita uma análise das discrepâncias de assentamento ocorridas na cimentação de coroas totais metálicas aliviadas ou não, internamente, sobre preparos com término cervical em chanfro; linha zero ou lâmina de faca; plano inclinado em 135°; ombro reto ou degrau em 90° e ombro reto ou degrau em 90°, associado a um bisel em 45°. Empregaram-se quatro tipos de cimentos, sendo três classificados como temporários à base de óxido de zinco e eugenol (Temp Bond e Provy) e outro sem eugenol (Temp Bond NE); e um quarto indicado para cimentações definitivas, cimento de Fosfato de Zinco. Idealizou-se modelos-padrão usinados em aço inoxidável, com características de um preparo para coroa total metálica em um primeiro molar inferior variando-se os términos cervicais conforme estabelecido. Foram obtidas cápsulas metálicas usinadas em aço inoxidável e perfeitamente adaptadas aos modelos-padrão com os términos cervicais correspondentes, nas condições de estarem aliviadas internamente ou não. Empregou-se uma técnica de cimentação padronizada para assentamento destas cápsulas metálicas nos modelos-padrão respectivos. Através de metodologia original promoveu-se a mensuração da discrepância de assentamento nos corpos-de-prova, com o aparelho Metroscópio Horizontal. Concluiu-se que: a) o alívio executado nas superfícies internas das coroas diminui de forma estatisticamente significante a discrepância marginal após a cimentação, independentemente do tipo de cimento empregado e da forma do término cervical adotada; b) o término cervical do preparo no modelo-padrão tipo Lâmina de Faca foi o que apresentou menor discrepância, independente do cimento empregado, seguido pelo Plano Inclinado, Chanfro, Ombro Biselado e Ombro Reto; c) os términos cervicais em Chanfro, Plano Inclinado e Lâmina de Faca, quando analisadas as amostras dos corpos-de-prova com alívio, .... / Abstract: Seating discrepancies during cementation of complete metal crowns internally relieved or not with various finishing lines and cementing agents. This study evaluated the discrepancies during cementation of complete metal crowns either relieved or not on preparation with various margin designs: chamfer, knife edge, 135 degree shoulder, 90 degree shoulder, 90 degree shoulder with 45 degree bevel. Four types of cements, three temporary and one definitive were used: 1- zinc oxide and eugenol temporary cement (Temp Bond); 2- zinc oxide and eugenol temporary cement (Provy); 3- no eugenol temporary cement (Temp Bond NE) and 4- zinc phosphate cement (S.S.White). Machined stainless dies were fabricated to resemble complete crown preparations for a lower first molar with various finishing lines. Machined stainless steel copings, either internally relieved or not were also fabricated to fit the metal dies. A controlled technique was developed to assess seating discrepancies under the horizontal metroscope. Results showed: a) the internally relieved crowns showed after cementation statistically significant reduction of marginal discrepancies regardless of cement type or margin desing; b) knife edge finishing lines showed least dicrepancies regardless of cement type followed by the 135 degree shoulder, chamfer, bevelled 90 degree shoulder and 90 degree shoulder; c) internally relieved copings with chamfer, 135 degree shoulder and knife edge finishing lines showed no statiscally significant marginal discrepancies. This indicates that any of them yields favorable results; d) regarding cements, the least marginal discrepancies were found with Temp Bond NE followed by Temp Bond, Provy and finally by the Zinc Phosphate Cement (S.S.White) / Doutor
150

Propriedades físicas e mecânicas de um cimento de ionômero de vidro após a incorporação de nanopartículas de dióxido de titânio /

Cunha, Juliana Maria Albano. January 2014 (has links)
Orientador: Ângela Cristina Cilense Zuanon / Banca: Alessandra Nara de Souza Rastelli / Banca: Maria Cristina Borsatto / Resumo: A adição de nanopartículas aos materiais odontológicos busca melhorar principalmente suas propriedades antibacterianas sem, contudo, alterar suas propriedades mecânicas e físicas. O objetivo deste estudo foi avaliar a influência da incorporação de nanopartículas de dióxido de titânio (TiO2) a um CIV convencional (Ketac Molar EasyMix) sobre suas propriedades mecânicas (dureza Vickers e resistência a compressão axial) e físicas (rugosidade e porosidade). Para todos os testes foram adotados quatro grupos (n=10): controle (sem adição de nanopartículas), 1, 2 e 5% em peso de TiO2. A dureza Vickers foi avaliada por meio do microdurômetro digital (Micromet 2100), a compressão axial por máquina de testes universais (EMIC-DL 2000), a rugosidade por rugosímetro (Mitutoyo SJ-400) e a porosidade por imagens de microscopia eletrônica de varredura (SM-300), analisadas pelo software Image J. Os dados foram analisados pela Análise de variância (ANOVA) a um critério fixo seguida do pós-teste de Tukey, com nível de significância de 5%. Houve diferença estatisticamente significativa para os experimentos dureza Vickers (p ≤ 0.001) e rugosidade (p = 0.010). Observamos que o CIV contendo 1% ou 2% de nanopartículas apresentou valores mais baixos para dureza. A rugosidade de superfície mostrou-se menor ao adicionar 2% e 5% de nanopartículas. Imagens em MEV mostraram não haver mudanças significativas na morfologia da porosidade na superfície do CIV. A adição de 5% de nanopartículas de TiO2 ao CIV convencional proporcionou resultados promissores, uma vez que não comprometeu suas propriedades mecânicas e físicas, e melhorou a rugosidade de superfície. Assim, a adição da nanopartícula de TiO2 a 5% ao Ketac Molar EasyMix sugere sua indicação clínica. / Abstract: The addition of nanoparticles to dental materials mainly searches to improve the antibacterial properties without changing their mechanical and physical properties. The aim of this study was to evaluate the influence of the incorporation of titanium dioxide (TiO2) nanoparticles to conventional glass ionomer cement (GIC) (Ketac Molar EasyMix) on mechanical (Vickers hardness and compressive strength) and physical (roughness and porosity) properties. For all experiments four groups (n=10) were used: control (without addition of nanoparticles), 1%, 2%, 5% (w/w) of TiO2. The Vickers hardness was measured using a digital hardness (Micromet 2100), compressive strength using a universal testing machine (EMIC-DL 2000), the roughness using a profilometer (Mitutoyo SJ-400) and for porosity, images were made using scanning electron microscopy (SM-300) and analyzed by Image J-software. The data were analyzed by one-way ANOVA and Tukey's post hoc test, with the level of significance set at 5%. There were statistically significant differences for the experiments of Vickers hardness (p ≤ 0.001) and roughness (p = 0.010). We observed that the GIC containing 1% or 2% of nanoparticles had lower values for hardness and the surface roughness was lower by adding 2% and 5% of nanoparticles. SEM images showed no significant changes in surface morphology of the GIC. The addition of 5% (w/w) TiO2 nanoparticles to conventional GIC provides promising results, since it does not compromise the physical and mechanical properties and improves surface roughness. The addition of TiO2 nanoparticle to Ketac Molar EasyMix suggests clinical indication. / Mestre

Page generated in 0.0701 seconds