• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 874
  • 51
  • 51
  • 51
  • 50
  • 39
  • 8
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 2
  • 1
  • Tagged with
  • 889
  • 425
  • 367
  • 327
  • 266
  • 195
  • 182
  • 176
  • 169
  • 162
  • 146
  • 137
  • 129
  • 126
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Influência da limpeza pós-condicionamento e do método de secagem do silano sobre a união resina-cerâmica

Siedschlag, Gustavo January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-03-04T18:55:09Z (GMT). No. of bitstreams: 1 304974.pdf: 373000829 bytes, checksum: a030a66c698daa104aecb8ec6bb46db5 (MD5) / Objetivos: avaliar a influência da limpeza pós-condicionamento e do método de secagem do silano sobre a resistência de união à microtração (µTBS) entre cimento resinoso e cerâmica reforçada por di-silicato de lítio. Métodos: Pastilhas cerâmicas (IPS e.max CAD) foram tratadas com ácido hidrofluorídrico (HF) por 20 s e em seguida distribuídas em 06 grupos, de acordo com os protocolos de limpeza póscondicionamento e de secagem do silano (n = 30): 1) sem limpeza (SL) (água corrente 20 s) + silano não aquecido/23ºC (SNA) (SL/SNA - controle 1); 2) SL + silano aquecido/ar quente 100±5ºC, 1 min (SA) (SL/SA - controle 2); 3) spray ar-água 30 s (SAA) + SNA (SAA/SNA); 4) SAA + SA (SAA/SA); 5) SAA + ácido fosfórico 37% por 1 min/lavagem em água corrente 30 s (AF) + SNA (SAA/AF/SNA); 6) SAA + AF + SA (SAA/AF/SA). Após a cimentação com cimento resinoso, os espécimes foram armazenados (24 h, 37ºC) e preparados para o teste de microtração. Foram realizadas análise em MEV e EDX para determinação do modo de falha e caracterização da superfície cerâmica. Os dados foram analisados pelos testes ANOVA e Tukey HSD (a = 1%). Resultados: Houve influência significativa dos protocolos de limpeza pós-condicionamento, aquecimento do silano bem como a interação entre os dois na µTBS (p < 0.001). Os valores em MPa foram SL/SNA (0.0, D), SL/SA (11.3, C), SAA/SNA (32.3, A), SAA/SA (28.6, AB), SAA/AF/SNA (25.2, B), SAA/AF/SA (30.1, AB). O modo de falha foi predominantemente do tipo adesivo para os grupos sem limpeza, e misto para os grupos limpos com spray ar-água somente ou associado ao ácido fosfórico. A utilização adicional do AF após o SAA não melhorou a µTBS, comparado ao grupo limpo apenas com SAA, independentemente do método de secagem do silano. A análise em MEV revelou uma redução nas microretenções e porosidades superficiais nos grupos limpos com AF bem como a presença de novos resíduos salinos, caracterizados pela análise EDX. Conclusões: Os diferentes resíduos formados pela aplicação de ambos os ácidos (HF e AF) reduziram a µTBS para a cerâmica de di-silicato de lítio (IPS e.max CAD). O spray ar-água foi o método de limpeza pós-condicionamento mais efetivo na remoção dos resíduos e gerou as maiores médias de resistência de união. O aquecimento do silano não demonstrou ser um passo relevante na cimentação adesiva quando a cerâmica foi devidamente limpa. / Objectives: To evaluate the influence of post-etching cleaning and silane air-drying on the microtensile bond strength (µTBS) between resin cement and lithium di-silicate ceramic. Methods: Ceramic pallets (IPS e.max CAD) were treated with hydrofluoric acid (HF, 20s) and divided into 06 groups, according to the post-etching cleaning and silane air drying protocols (n=30): 1) no cleaning/tap water, 20s (NC) + silane not heat dried/23ºC (SNH) (NC/SNH - control 1); 2) NC + silane heat dried/warm air 100±5°C, 1 min (SH) ( NC/SH - control 2), 3) air-water spray 30 s (AWS) + SNH (AWS/SNH), 4) AWS + SH (AWS/SH), 5) AWS + 37% phosphoric acid brushed for 1 min (PA) + SNH (AWS/PA/SNH), 6) AWS + PA + SH (AWS/PA/SH). After cementation with resin cement, the blocs were stored (24 h, 37 ° C) and prepared for the microtensile test. SEM and EDX analysis was additionally performed to determine the failure mode and characterize the ceramic surface. Data were analyzed by ANOVA and Tukey HSD (a = 1%). Results: There was significant influence of the post-etching cleaning and silane drying protocols and the interaction between this two factors on the µTBS (p <0.001). The values (MPa) were NC/SNH (0.0, D), NC/SH (11.3, C), AWS/SNH (32.3, A), AWS/SH (28.6, B), AWS/PA/SNH (25.2, B ), AWS/PA/SH (30.1, AB). The failure mode was predominantly adhesive for groups NC/SNH and NC/SH and mixed for the others. The additional use of PA after AWS did not improve the µTBS compared to the group cleaned only with AWS, regardless of the silane air-drying protocol. SEM analysis revealed a reduction in microretentions and porosities at the groups cleaned with PA and the presence of new salt residues, characterized by EDX analysis. Conclusions: The different residues formed by the application of both acids (HF and PA) reduced the µTBS for the lithium di-silicate ceramic. The air-water spray post-etching cleaning protocol was more effective in removing the residues and generated the best mean bond strength. Silane heat drying shown not to be an important step for the adhesive cementation when the ceramic surface was properly cleaned.
102

Análise da interface adesiva de materiais obturadores à dentina do canal radicular

Tedesco, Maybell January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T05:06:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2016Bitstream added on 2017-04-04T04:10:03Z : No. of bitstreams: 1 340360.pdf: 2069422 bytes, checksum: 236ac1415e494885dedbc502f10fe93e (MD5) / A adesão em endodontia é um processo complexo que depende de fatores químicos e mecânicos relativos à interação dos cimentos endodônticos à dentina das paredes do canal radicular. O material obturador firmemente aderido à dentina contribui para o preenchimento tridimensional do canal e longevidade da obturação. Estudos comparativos com diferentes materiais e métodos observacionais são essenciais para a avaliação e desenvolvimento de novos produtos. Sendo assim, os objetivos do presente estudo, ex vivo e in vitro, foram: 1º- Comparar a acurácia da microscopia eletrônica de varredura (MEV) com a microscopia de varredura a laser confocal (Confocal) na análise da interface adesiva e penetração intratubular de dois cimentos endodônticos, AH Plus e Endofill; 2º- Avaliar a existência de correlação entre resistência de união à dentina e penetração intratubular de três cimentos endodônticos: Endofill, AH Plus e MTA Fillapex por meio dos testes de push-out e análise com Confocal; 3º- Avaliar a influência da adição do corante fluorescente, rodamina B, nas propriedades físicas-químicas de dois cimentos endodônticos, AH Plus e MTA Fillapex. Embora os objetivos sejam correlacionados, os experimentos tiveram metodologias e amostras distintas, o que fez com que os resultados do presente estudo fossem apresentados em três artigos. Cada artigo foi detalhado de acordo com os objetivos propostos, recebeu análise estatística dos resultados obtidos e discussão embasada na literatura vigente.<br> / Abstract : The adhesion in endodontics is a complex process witch depends on physical and mechanical factors related to the interaction between endodontic sealer to dentine canal walls. The filling material firmly attached to dentin contribute to the tridimensional filling and longevity of treatment. Comparative studies with different materials and observational methods are essential to evaluate and development of new products. Therefore, the objectives of the present study, ex vivo e in vitro were: 1º- Compare the acuracy of the scanning electronic microscopy evaluation (SEM) with confocal laser scanning microscopy (Confocal) on the adhesive interface and intratubular penetration evaluation of two endodontic sealers, AH Plus and Endofill; 2º- Evaluate the existence of a correlation between bond strength (BS) and intratubular penetration of three endodontic sealers: Endofill, AH Plus and MTA Fillapex, through push-out and Confocal evaluation; 3º- Evaluate the influence of the addition of a fluorescent dye, rhodamine B, in the physical-chemical properties of two endodontic sealers, AH Plus e MTA Fillapex. Although the objectives are correlated, the experiments had different methodology and samples; that makes the results of the present study be presented in three individual articles. Each article was detailed according to the goals proposed and have received statistical analysis of the data and discussion based on the current literature.
103

Avaliação da efetividade de diferentes técnicas de remoção do excesso de cimento resinoso e sua influência na microinfiltração marginal de restaurações indiretas

Ferreira, Isana Álvares January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T17:46:38Z (GMT). No. of bitstreams: 1 202859.pdf: 1428126 bytes, checksum: 3d3305744e59b748873306bacf4b4ec6 (MD5) / Este estudo, in vitro, teve como objetivo avaliar a efetividade de diferentes técnicas de remoção do excesso de cimento resinoso e sua relação na microinfiltração marginal de restaurações indiretas de resina composta. Em quarenta pré-molares hígidos foram confeccionadas duas cavidades ocluso-proximais e restauradas com inlays de resina composta. Durante a cimentação, as peças foram posicionadas no dente e pressionadas para que o cimento escoasse em toda margem para posterior remoçao com: fio dental (grupo 1); sonda exploradora (grupo 2), sistema EVA (grupo 3) e ultra-som (grupo 4). Concluiu-se que o fio dental é mais efetivo estatisticamente ao sistema EVA e ao ultra-som e que a efetividade da sonda exploradora na remoção do excesso de cimento resinoso é superior ao ultra-som, embora similar estatisticamente ao fio dental e ao sistema EVA.
104

Determinação da resistência flexural de cimentos resinosos comerciais, com variação do sistema de ativação e tempo de armazenamento pós-ativação

Ferreira, Ana Paula Ribeiro Bonilauri 19 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T21:26:39Z (GMT). No. of bitstreams: 1 185447.pdf: 1185471 bytes, checksum: a9ac4351115382acbe72344a530a546a (MD5) / Este estudo investigou a resistência flexural de amostras confeccionadas com os cimentos resinosos duais Enforce, RelyX CRA e Variolink II submetidas à dupla ativação ou apenas à ativação química, aos trinta minutos e vinte e quatro horas após o início da polimerização. O cimento Enforce apresentou os valores mais altos de resistência flexural, independentemente do tipo de ativação e do tempo de armazenamento. No período de 30 minutos de armazenamento, não foram observadas significâncias estatísticas entre os materiais e a dupla ativação. Já, na polimerização química, o Enforce foi superior aos outros materiais testados neste mesmo tipo de polimerização. No período de 24 horas de armazenamento, não houve significâncias estatísticas na interação materiais x tipos de ativação.
105

Influência do tamanho de partículas nas propriedades físico-químicas do cimento endodôntico CER

Zagato, Erick Fazanha [UNESP] 13 January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-01-13Bitstream added on 2014-06-13T19:12:24Z : No. of bitstreams: 1 zagato_ef_me_ilha.pdf: 261736 bytes, checksum: d0251ba5867a2a4a3e37c5f78ca9c4ee (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Desde 1993, o mineral trioxide aggregate tem sido amplamente investigado e os resultados confirmam que ele possui excelentes propriedades físicas, químicas e biológicas. Apesar do sucesso e uso deste cimento, duas dificuldades têm sido apontadas pelos profissionais: o difícil manuseio e tempo de presa muito longo. Recentemente, um novo cimento endodôntico, intitulado CER, foi desenvolvido no laboratório do grupo Vidros e Cerâmicas. A inclusão de uma emulsão em sua composição deu ao cimento uma extraordinária consistência de trabalho e uma acentuada redução no tempo de presa. O primeiro estudo com o material mostrou que o CER tem a mesma habilidade de liberar íons que o mineral trioxide aggregate. Como continuidade na caracterização do CER, este trabalho apresenta resultados obtidos com o estudo do efeito do tamanho de partículas do pó de cimento no tempo de presa e na expansão térmica, e um estudo comparativo de infiltração marginal entre o CER e o MTA-Angelus. / Since 1993, the mineral trioxide aggregate has been widely investigated and the results confirm that it has excellent physical, chemical, and biologic properties. In spite of this, one of the difficulties reported by clinicians when using MTA is its poor handling characteristic and lengthy setting time. Recently, a novel endodontic cements, entitled CER, it was developed in the laboratory of the Glasses and Ceramic group. The inclusion of an emulsion in its composition gave to it an extraordinary handling and one accentuated reduction in the setting time as compared to MTA. The first study with the material showed that CER has the same ability to release ions than the mineral trioxide aggregate. This work presents results obtained from study of effects of particle size of the CER cement powder on setting time and thermal expansion, and from a comparative study of sealing ability between CER and MTA-Angelus.
106

Avaliação da microdureza de quatro cimentos resinosos duais fotopolimerizados através da interposição de diferentes materiais: estudo in vitro

Umetsubo, Luzia Sakaguti [UNESP] 16 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-16Bitstream added on 2014-06-13T21:02:26Z : No. of bitstreams: 1 umetsubo_ls_dr_sjc.pdf: 496272 bytes, checksum: a357a92f3b43c76cc064965c3de92548 (MD5) / Este estudo avaliou por testes de microdureza o grau de polimerização de quatro cimentos resinosos duais: Bistite II, Enforce, RelyX ARC e Variolink II, fotopolimerizados através da interposição de barreiras confeccionadas com materiais utilizados em retaurações estéticas indiretas. Foram confeccionados 72 espécimes para cada marca de cimento, divididos em 6 grupos, segundo o tipo de barreira utilizada na interposição, durante a sua fotopolimerização: G1: sem barreira; G2: Resina composta Cesead; G3: Inceram alumina/Allceram; G4: IPS Empress; G5: Inceram zirconia/Allceram; G6: fragmento dental. A fotopolimerização foi realizada com luz halógena Optilux 401 (Demetron) com 650 mW/cm2 de potência e os ensaios foram realizados em três períodos: imediata, 24h e 7dias, em um Microhardness Tester FM 700, sob cargas de 50gf durante 15s, cujos valores de microdureza foram obtidos em HV. As médias dos valores em HV foram submetidos à ANOVA e teste de Tukey. As condições de G3 e G5 resultaram em polimerização deficiente do cimento, que não permitiram a realização dos ensaios. O cimento Bistite teve a maior dureza no grupo controle e o menor com a interposição de resina composta. O RelyX ARC teve os valores de microdureza mais estáveis nas condições analisadas em todos os períodos de avaliação. O Enforce e o Variolink foram intermediários e semelhantes entre si. A interposição de materiais durante a fotopolimerização de cimentos resinosos duais, interfere na microdureza dos mesmos. Quando da utilização de alumina ou zirconia, outro modo de polimerização ou tipo de cimento deve ser utilizado. / This study evaluated by microhardness tests the curing degree of four dual cured cements: Bistite II, Enforce, RelyX ARC and Variolink II, lightcured through the interference of barriers made with materials used in indirect aesthetic restorations. 72 specimens were made for each cement that was divided into 6 groups, according to the barrier type used in the interference, during the light activation G1: without barrier; G2: Cesead, a composed resin; G3: Inceram alumina/Allceram; G4: IPS Empress; G5: Inceram zirconia/Allceram; G6: dental fragment. The lightcuring was accomplished with a conventional halogen unit, Optilux 401 (Demetron) with 650 mW/cm2 and the measurements were accomplished in three periods: immediate, 24hours and 7days, in a Microhardness Tester FM 700, under loads of 50gf during 15seconds. Microhardness values were obtained in HV. The averages of the HV values were submitted to ANOVA and Tukey test. The G3 and G5 groups resulted in deficient polymerization of the cement, that they didn't allow the accomplishment of the rehearsals. The Bistite cement had the largest hardness in the control group and the smallest with the interference of Cesead. RelyX ARC had the stableer values of microhardness in the analyzed conditions in all of the evaluation periods. Enforce and Variolink were intermediate and similar amongst them. The interference of barriers during the lightcuring of dual resinous cements interferes in the microhardness of the same ones. When a restoration of alumina or zirconia is used, other polymerization way or cement type should be used.
107

Resistência a extrusão de retentores intra-radiculares de fibra de vidro avaliando: técnica de confecção e cimento resinoso

Clavijo, Victor Grover Rene [UNESP] 24 January 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-01-24Bitstream added on 2014-06-13T18:42:03Z : No. of bitstreams: 1 clavijo_vgr_dr_arafo.pdf: 969958 bytes, checksum: 57064b07ad94167d21ebb9ba66873da2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste estudo avaliou-se a resistência ao cisalhamento por extrusão de pinos de fibra de vidro, reembasados ou não com compósito, cimentados com dois tipos de cimentos resinosos em dentina intra-radicular, avaliando os segmentos cervical, médio e apical. Selecionaram-se 40 incisivos bovinos com dimensões semelhantes, removendo a porção coronária, padronizando o comprimento das raízes em 14 mm. Após, incluiu-se as raízes em resina acrílica, realizando tratamento endodôntico e, então o preparo dos espaços para os pinos, dividindo- as, em seguida, aleatoriamente em quatro grupos com dez amostras cada. Os elementos do grupo 1 receberam retentores de fibra de vidro cimentados com cimento resinoso RelyX ARC, grupo 2 retentores de fibra de vidro cimentados com cimento resinoso RelyX U100, grupo 3 retentores de fibra de vidro reembasados com resina composta e cimentados com cimento resinoso RelyX ARC e grupo 4 retentores de fibra de vidro reembasados com resina composta e cimentados com cimento resinoso RelyX U100. Ao término dos procedimentos de cimentação, realizou-se a secção dos segmentos radiculares, submetendo, então, os corpos-de-prova ao teste push-out em máquina de ensaios universal, através de ponta ativa cilíndrica com 1 mm de diâmetro, à velocidade de 0,5 mm/min, até extrusão do retentor. Obteve-se os seguintes valores médios de resistência de união, em MPa: grupo 1, terços cervical = 6,22 ± 2,64(a), médio = 4,25 ± 2,01(a) e apical = 4,45± 2,81(a); grupo 2, terços cervical = 5,04 ± 2,34(a), médio = 3,06 ± 2,12(a) e apical = 3,26 ± 2,38(a). grupo 3, terços cervical = 11,85 ± 1,67(b), médio = 11,83 ± 3,84(b) e apical = 10,39 ± 2,44(b). grupo 4, terços cervical = 12,05 ± 1,14(b), médio = 11,98 ± 3,23(b) e apical = 10,96 ± 2,14(b). Submeteram-se os valores à análise de variância e ao teste de Tukey com nível de significância de 5% indicadas... / This study evaluated the bond strength of fiber posts, relined or not with composite resin, luted with resinous cement to radicular dentin, evaluating cervical, median and apical root segments. Fourty bovine incisors, with similar dimensions, were selected and cut 16 mm from the apical limit. The roots were embedded in acrylic resin and the radicular canals were root treated and post space prepared with a depth of 9 mm. Samples were randomly assigned to two groups of ten roots each. Group 1 received glass fiber posts luted with dual-cure resin cement RelyX ARC in association with a bonding system. In Group 2 the same type of posts were relined with composite for further cementation with resin cement RelyX U100. In Group 3, glass fiber post were relined with composite and cemented with resin cement RelyX ARC and in Group 4 glass fiber posts were relined ith composite and cemented with resin cement RelyX U100. After cementation procedures roots were sectioned transversally and three sections, from cervical, medium and apical thirds were obtained. Push-out test was performed in a universal testing machine with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion. Collected data was statistically analyzed by two- way ANOVA and Tukey HSD test (p<0,05). The measured retention strengths for cervical, medium and apical thirds were: Group 1, cervical thirds = 6,22 ± 2,64(a), medium = 4,25 ± 2,01(a) e apical = 4,45± 2,81(a); group 2, cervical thirds = 5,04 ± 2,34(a), medium = 3,06 ± 2,12(a) and apical = 3,26 ± 2,38(a). Group 3, cervical thirds = 11,85 ± 1,67(b), medium = 11,83 ± 3,84(b) and apical = 10,39 ± 2,44(b). Group 4, cervical thirds = 12,05 ± 1,14(b), medium = 11,98 ± 3,23(b) and apical = 10,96 ± 2,14(b). Glass fiber composite relined posts presented statistically higher retention values in cervical, medium and apical thirds when compared... (Complete abstract click electronic access below)
108

Citotoxicidade, genotoxicidade e expressão gênica em células da polpa dental humana sensibilizadas por cimentos endodônticos

Rabelo, Sylvia Bicalho [UNESP] 14 September 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-09-14Bitstream added on 2014-06-13T19:41:51Z : No. of bitstreams: 1 rabelo_sb_dr_sjc.pdf: 891440 bytes, checksum: ccb82a07266cfe393903fec2e52c87af (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O sucesso dos tratamentos endodônticos está relacionado ao correto diagnóstico das alterações pulpares, à qualidade do preparo biomecânico e da obturação dos canais radiculares, bem como à compatibilidade entre os cimentos obturadores com os tecidos adjacentes ao canal. Atualmente a busca de bom comportamento biológico destes cimentos se faz de extrema importância. O presente estudo teve como objetivo analisar a citotoxicidade e a genotoxicidade dos extratos de três cimentos endodônticos e seus efeitos sobre a expressão dos genes BMP2, ALP, RUNX2, BGLAP, OPN e DMP1 em células da polpa dental humana. Foram utilizadas células primárias de tecidos pulpares de terceiro molar com rizogênese incompleta. Cimentos endodônticos foram depositados em placas de 24 poços e armazenados a 37°C por 6 h; cada espécime foi colocado em contato com 2,7 ml de meio de cultura (DMEM-F12) e as amostras foram incubadas por 24 h, a 37°C. Extratos originais (1:1) de cada material foram diluídos em série até 1:32 e analisados quanto a citotoxicidade pelo ensaio de MTT. Após a obtenção de uma diluição que não fosse extremamente tóxica e não interferisse demasiadamente na replicação celular (subdose), foi realizado o teste de micronúcleo para avaliação da genotoxicidade dos materiais. A expressão dos genes foi verificada por RT-PCR em tempo real, em 6, 12 e 24 h. O RNA total foi isolado e retrotranscrito. Os testes de citotoxicidade indicaram que a sobrevivência celular foi afetada pelos extratos na seguinte ordem: EndoREZ > AH Plus > RoekoSeal ≥ MTA. O EndoREZ propiciou o maior número de micronúleos no ensaio de genotoxicidade. A quantificação relativa indicou que em 24 h, o AH Plus e o EndoREZ agiram de modo similar, aumentando a expressão da OPN e reduzindo a ALP; o RoekoSeal gerou expressão da OPN... / The success of endodontic therapy is related to the correct pulp and periapical alterations diagnosis; to the good biomechanical instrumentation and to the root canal sealing quality; to the compatibility between the endodontic sealers and the root canal surrounding tissues as well. Nowadays, the seeking for a sealer with good biological behavior is extremely important. The aim of this study was to analyze the cytotoxicity and the genotoxicity of three endodontic sealers and their effects on the expression of the genes BMP-2, ALP, RUNX2, BGLAP, SPP1 and DMP1 in human dental pulp cells. Primary cells from the 5th passage obtained from pulp tissue of third molar with incomplete rizogenesis were used in this study. Endodontic sealers were placed in 24 well plates and stored at 37°C for 6 hours. After that, each specimen was covered with 2.7 ml of cell culture media (DMEM-F12) and incubated afterwards at 37°C for 24 h. Original extracts (1:1) of each material were serially diluted up to 1:32 and the citotoxicity was analyzed by MTT assay. After obtaining extracts subdose, non very toxic or non interfering on cell replication, genotoxicity was evaluated by micronucleus test. The gene expression was accessed by Real Time RT-PCR, after extracts exposure of 6, 12 and 24 h. Total RNA was isolate and retrotranscribed. The citotoxicity test has showed that cell survival was affected in the following order: EndoREZ > AH Plus > Roeko Seal ≥ MTA. EndoREZ has caused the highest score in micronucleus assay. Relative quantification indicated that at 24 h, AH Plus and EndoREZ increased OPN and reduced ALP; RoekoSeal has caused decreasing OPN... (Complete abstract click electronic access below)
109

Tratamentos de superfície e aplicação de excitação ultrassônica em reparos de restauração de cimento de ionômero de vidro

Azevedo, Elcilaine Rizzato [UNESP] 30 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-30Bitstream added on 2014-06-13T19:03:56Z : No. of bitstreams: 1 azevedo_er_dr_arafo.pdf: 805855 bytes, checksum: c22c2ebf2198c2ca16681b4b692c7d27 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve como objetivo investigar a resistência máxima à tração de reparos de restaurações de CIV, após diferentes protocolos de tratamento de superfície e aplicação US. Foram confeccionados 15 corpos de prova para cada grupo experimental, os quais passaram por termociclagem (500 ciclos, de 5ºC e 55ºC ± 2ºC) e tratamento de superfície previamente a confecção do reparo, conforme segue: G1 – sem tratamento; G2 – tratamento de superfície com fresa diamantada; G3 – abrasão à ar; G4 – ácido fosfórico à 35%; G5 – ácido poliacrílico à 11,5%; G6 – fresa diamantada e ácido fosfórico à 35%; G7 - fresa diamantada e ácido poliacrílico à 11,5%; G8 - abrasão à ar e ácido fosfórico à 35%; G9 - abrasão à ar e ácido poliacrílico à 11,5%. O reparo foi confeccionado com CIV pigmentado com rodamina, para facilitar sua distinção. A excitação ultrassônica foi aplicada durante 0, 15 ou 30s para cada grupo. Após 24h de armazenamento, os corpos de prova foram seccionados em espécimes em forma de palito, com 0,9 mm2 de área de união e submetidos ao ensaio mecânico de microtração. As superfícies fraturadas foram avaliadas em lupa estereoscópica e classificadas em coesiva, adesiva ou mista. Foi considerada como variável dependente a resistência máxima a tração, e independentes o tratamento de superfície e a aplicação de US. As condições de homogeneidade de variâncias e de normalidade dos erros experimentais foram comprovadas, respectivamente pelos testes de Levene e de Shapiro-Wilk, complementada por comparações múltiplas pelo teste de Tukey. Adotou-se o nível de significância de 5% para a tomada de decisões. Os maiores valores de resistência de união dos reparos de cimentos de ionômero de vidro foram obtidos com o tratamento de fresa diamantada e ácido fosfórico. A aplicação do US (30 s) favoreceu a resistência de união... / The study aimed to evaluate the effect of different surface treatment protocols and the ultrasonic excitation on the microtensile bond stregth of the glass ionomer restoration repaired. A total of 135 specimens was made using an increment technique and it was thermocycled (500 cycles between 5ºC and 55ºC ± 2ºC). The specimens were separated into 9 groups of 15, and each group then received a different surface treatment before the repair prepare: G1 control, without treatment; G2 diamond bur; G3 air abrasion; G4 35% fosforic acid; G5 11,5% poliacrilic acid; G6 diamond bur and 35% fosforic acid; G7 diamond bur and 11,5% poliacrilic acid; G8 air abrasion and 35% fosforic acid; G9 air abrasion and 11,5% poliacrilic acid. The repair was prepared with glass ionomer cement (Ketac Molar Easymix) colored with saturated rhodamine B (Fluka, Buchs, Switzerland) for its distinction. The samples were submitted to the ultrasonic excitation during 0, 15 and 30 seconds and, then stored in 37°C ±2°C water during 24 h. Rectangular bar specimens with a cross-sectional area of 0.9 mm² were prepared and then submitted to the microtensile test. The fracture surfaces were evaluated under stereomicroscope and classified as cohesive, adhesive or mixed. Microtensile strength values are shown in MPa. The dependent and independent variables were considered, respectively, ultimate tensile strength and the surface treatments and ultrasonic excitation. The effects of each surface treatment and ultrasonic excitation on the microtensile strength (MPa) were determined by ANOVA and Tukey tests. The highest values of bond strength of repair of glass ionomer cement were obtained with the treatment of diamond cutter and phosphoric acid. The application of the U.S. (30 s) enhanced the bond strength of repair of ionomer after the combination of mechanical treatment with polyacrylic... (Complete abstract click electronic access below)
110

Eficácia do clareamento dentário em superfícies submetidas á colagem ortodôntica de brackets sob diferentes protocolos

Ambrosio, Aldrieli Regina [UNESP] 05 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-05Bitstream added on 2014-06-13T20:05:07Z : No. of bitstreams: 1 000735865.pdf: 1350791 bytes, checksum: 8b676e8bc19c2ecb2b9d0adcd4f56416 (MD5) / Objetivo: Avaliamos in vitro as variações da sensação de cor (ΔE) e suas correlações após o clareamento de dentes submetidos à colagem e remoção de brackets ortodônticos, considerando: 1) o tempo de condicionamento ácido (15, 30 e 60 segundos); 2) os sistemas adesivos (TransbondTMXT, Opal Seal/Bond e TransbondTM Plus SEP) e 3) o momento em que o clareamento foi realizado em relação à presença de brackets (antes, durante ou depois), bem como o índice de adesivo remanescente (IAR) após descolagem dos brackets. Materiais e Métodos: Este trabalho foi subdividido em três artigos para abordar cada um dos objetivos propostos. A amostra foi composta de 270 pré-molares humanos, distribuídos aleatoriamente em 9 grupos: controle negativo (reprodutibilidade); controle positivo (apenas clareamento dentário); e 7 grupos experimentais. A determinação da cor dentária foi obtida pelo sistema CIELab, a partir de dados do espectrofotômetro, em avaliações da cor prévia ao clareamento e em 1, 15 e 30 dias após. Para verificar se existia diferença entre os grupos foi aplicada ANOVA a um fator, uma vez que o tamanho da amostra de cada grupo foi de n=30 (p < 0,05). E quando ANOVA indicou diferença, para identificar quais grupos diferiam entre si, foi aplicado o teste de comparações múltiplas de Tukey para variâncias homogêneas, identificadas pelo teste de Levene (p < 0,05). Resultados: O ΔE desde o pré-clareamento até 15 e 30 dias após foi estatisticamente diferente entre: o controle e o grupo com condicionamento ácido durando 15 segundos (p<0,05); o controle e os grupos colados com sistema adesivo TransbondTM XT e TransbondTM Plus SEP; assim como entre o grupo colado com Opal Seal/Bond e TransbondTM Plus SEP. Quanto ao momento em o clareamento foi realizado, apenas a variável IAR apresentou diferença estatisticamente significante nos valores médios, entre os três grupos experimentais... / Objective: To evaluate in vitro the degree of color changes (ΔE) and their correlations after bleaching tooth surfaces subjected to orthodontic brackets bonding and debonding, regarding: 1) the etching time (15, 30 and 60 seconds); 2) the adhesive system (TransbondTM XT, Opal Seal/Bond and TransbondTM Plus SEP); 3) the time point in which bleaching was performed (before, during and after bonding of brackets) and the adhesive remnant index (IAR) after bracket debonbing. Materials and Methods: This study was divided in three articles to address each of the proposed objectives. The sample consisted of 270 extracted premolars randomly divided in 9 groups: negative control (reproducibility); positive control (tooth bleaching only); and 7 experimental groups. The tooth color was determined by the CIELab system using the spectrophotometer data, in evaluations prior to bleaching and 1, 15 and 30 days after bleaching. To test whether there was difference between the groups one-way ANOVA was used, since the sample size of each group was n=30 (p<0,05). When ANOVA indicated a difference, in order to identify which groups differed from each other, we applied the multiple comparison test of Tukey for homogeneity of variances, identified by the Levene test (p < 0,05). Results: The ΔE from pre-bleaching up to 15 and 30 days after bleaching was statistically different between: control and etching time group of 15 seconds (p < 0,05); control and groups bonded withTransbondTM XT and TransbondTM Plus SEP bonding systems; as well as the group bonded with Opal Seal/Bond and TransbondTM Plus SEP. Regarding the time when the bleaching was performed, only the variable IAR presented statistically significant difference in the mean values among the three groups (p < 0,05). As for correlations, the color variation observed 1 day after bleaching was strongly correlated with 15 days after bleaching, as well as 15 to 30 days...

Page generated in 0.1129 seconds