• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Bending of circular-section bonded rubber blocks.

Horton, J.M., Tupholme, Geoffrey E., Gover, Michael J.C. January 2002 (has links)
No / Convenient exact closed-form expressions are derived for calculating the bending stiffness of and stresses within loaded cylindrical bonded rubber blocks of circular cross-section. The particular solutions for simple bending, cantilever loading and apparent shear situations are deduced and studied in detail. The shapes of the deformed profiles are discussed and confirmation is provided that the previously adopted assumption of parabolic profiles of the deformed lateral curved surface is only valid for blocks of very small aspect ratio. In simple bending a relationship which is more realistic than those hitherto suggested is derived for the couple required to maintain a specified rotation of the loaded end of the block. In apparent shear an exact expression for the ratio of the true to the apparent shear modulus is derived, and compared with the experimental data. An improved approximate relation is deduced.
2

Análise teórico-experimental de pilares mistos preenchidos de seção circular / Theoretical and experimental analysis of circular concrete-filled steel tubular columns

Oliveira, Walter Luiz Andrade de 06 June 2008 (has links)
Os pilares mistos preenchidos são elementos estruturais constituídos por um tubo de aço preenchido com concreto de qualidade estrutural. O objetivo principal do trabalho foi estudar o comportamento dos pilares mistos preenchidos de seção circular. Para isso, foi avaliada a influência da resistência à compressão do concreto (fc), da esbeltez do pilar (L/D), da espessura do tubo de aço (t) e da forma de introdução do carregamento, se no núcleo de concreto ou na seção mista do pilar. Foram feitos ensaios experimentais de 64 pilares mistos preenchidos, submetidos à força de compressão centrada. Os resultados de capacidade resistente obtidos foram avaliados e comparados com os resultados de previsão segundo os procedimentos normativos estrangeiros do EUROCODE 4:2004, ANSI/AISC:2005 e CAN/CSA:2001 e do Projeto de Revisão da Norma Brasileira (PR-NBR 8800, draft 2008). Os resultados previstos foram maiores que os experimentais para os procedimentos do ANSI/AISC e da NBR e menores para os procedimentos do EC4 e do CAN/CSA. A partir da comparação dos valores de capacidade resistente experimentais e normativos, foi desenvolvido um estudo de confiabilidade dos valores de força resistente obtidos segundo as equações de dimensionamento dessas normas, por meio da estimativa do erro de modelo inerente a cada uma. Os resultados mostraram que o EC4 apresenta os índices de confiabilidade mais uniformes. Além disso, foi feita uma modelagem numérica dos pilares mistos preenchidos com relação L/D = 10, buscando obter o valor da capacidade resistente desses pilares e compará-los com os resultados experimentais. Embora o modelo numérico tenha representado adequadamente o comportamento dos pilares preenchidos esbeltos, os valores de força última foram inferiores aos experimentais. / Concrete-filled steel tubular columns are structural elements made of a steel tube filled with structural concrete. The main objective of this work was study the global behavior of concrete-filled steel tubular columns. For this, some variables were evaluated: concrete compressive strength (fc), length-to-diameter ratio (L/D), diameter-to-thickness ratio (D/t) and the type of load application (on concrete core or on composite cross section). Tests of 64 concrete filled columns were performed. The columns were subjected to axial load. The results of experimental compressive strength were compared to results from three different international codes (EUROCODE 4:2004, ANSI/AISC:2005 e CAN/CSA:2001) and the national NBR 8800, draft 2008. The results showed, in general, a conservative behavior of values predicted by NBR and ANSI/AISC e non-conservative values by EC4 and CAN/CSA. Based on comparisons between experimental values and codes predictions, an error model variable was estimated to each code and a reliability analysis was performed. The results indicate that the EC4 is the best code with less tendentious behavior of its design equation. A numerical analysis of columns with slenderness (L/D) equal to 10 was carried out to try to predict the peak load of columns and compare the results with those from experimental analysis. Althougth the results of the numerical analysis had a good match to the experimental ones, the values, in average, were conservatives.
3

Análise teórico-experimental de pilares mistos preenchidos de seção circular / Theoretical and experimental analysis of circular concrete-filled steel tubular columns

Walter Luiz Andrade de Oliveira 06 June 2008 (has links)
Os pilares mistos preenchidos são elementos estruturais constituídos por um tubo de aço preenchido com concreto de qualidade estrutural. O objetivo principal do trabalho foi estudar o comportamento dos pilares mistos preenchidos de seção circular. Para isso, foi avaliada a influência da resistência à compressão do concreto (fc), da esbeltez do pilar (L/D), da espessura do tubo de aço (t) e da forma de introdução do carregamento, se no núcleo de concreto ou na seção mista do pilar. Foram feitos ensaios experimentais de 64 pilares mistos preenchidos, submetidos à força de compressão centrada. Os resultados de capacidade resistente obtidos foram avaliados e comparados com os resultados de previsão segundo os procedimentos normativos estrangeiros do EUROCODE 4:2004, ANSI/AISC:2005 e CAN/CSA:2001 e do Projeto de Revisão da Norma Brasileira (PR-NBR 8800, draft 2008). Os resultados previstos foram maiores que os experimentais para os procedimentos do ANSI/AISC e da NBR e menores para os procedimentos do EC4 e do CAN/CSA. A partir da comparação dos valores de capacidade resistente experimentais e normativos, foi desenvolvido um estudo de confiabilidade dos valores de força resistente obtidos segundo as equações de dimensionamento dessas normas, por meio da estimativa do erro de modelo inerente a cada uma. Os resultados mostraram que o EC4 apresenta os índices de confiabilidade mais uniformes. Além disso, foi feita uma modelagem numérica dos pilares mistos preenchidos com relação L/D = 10, buscando obter o valor da capacidade resistente desses pilares e compará-los com os resultados experimentais. Embora o modelo numérico tenha representado adequadamente o comportamento dos pilares preenchidos esbeltos, os valores de força última foram inferiores aos experimentais. / Concrete-filled steel tubular columns are structural elements made of a steel tube filled with structural concrete. The main objective of this work was study the global behavior of concrete-filled steel tubular columns. For this, some variables were evaluated: concrete compressive strength (fc), length-to-diameter ratio (L/D), diameter-to-thickness ratio (D/t) and the type of load application (on concrete core or on composite cross section). Tests of 64 concrete filled columns were performed. The columns were subjected to axial load. The results of experimental compressive strength were compared to results from three different international codes (EUROCODE 4:2004, ANSI/AISC:2005 e CAN/CSA:2001) and the national NBR 8800, draft 2008. The results showed, in general, a conservative behavior of values predicted by NBR and ANSI/AISC e non-conservative values by EC4 and CAN/CSA. Based on comparisons between experimental values and codes predictions, an error model variable was estimated to each code and a reliability analysis was performed. The results indicate that the EC4 is the best code with less tendentious behavior of its design equation. A numerical analysis of columns with slenderness (L/D) equal to 10 was carried out to try to predict the peak load of columns and compare the results with those from experimental analysis. Althougth the results of the numerical analysis had a good match to the experimental ones, the values, in average, were conservatives.

Page generated in 0.0695 seconds