• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 7
  • 7
  • 7
  • 7
  • 6
  • 1
  • 1
  • 1
  • Tagged with
  • 40
  • 23
  • 20
  • 19
  • 14
  • 13
  • 11
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Análise da eficácia clareadora e dos efeitos adversos provocados pelo uso da luz violeta no clareamento dental /

Gallinari, Marjorie Oliveira January 2019 (has links)
Orientador: André Luiz Fraga Briso / Resumo: Pesquisadores tem proposto um clareamento dentário apenas com a irradiação da Luz violeta (VIO), sem a necessidade do gel clareador. Portanto foi o objetivo deste trabalho avaliar in vitro e in vivo este novo tratamento associado com diferentes concentrações de peróxido de hidrogênio (PH) quanto a sua eficácia clareadora e os possíveis efeitos adversos. Para o estudo in vitro, foram selecionados 567 (n=67) dentes e distribuídos em 9 grupos: Sem Gel(SG)-Sem Luz(SL), PH17,5%-SL, PH35%-SL, SG-LED/Laser(LED), PH17,5%-LED, PH35%-LED, SG-VIO, PH17,5%-VIO e PH35%-VIO. A aplicação dos géis seguiu as recomendações do fabricante. O LED foi irradiada 3 vezes de 3 minutos, a VIO foi irradiada 3 vezes de 7 minutos. Após os procedimentos clareadores, foram realizadas as análises de alteração cromática superficial e intensidade de fluorescência (n=10), considerando 5 tempos de análise (T0-inicial, T1-1º sessão, T2-2º sessão, T3-3º sessão, T4-14 dias após), alteração de cor em profundidade (n=15), condutância hidráulica (n=10), difusão do PH (n=10), viabilidade celular (n=8) e a variação da temperatura intrapulpar (n=10). Os dados foram submetidos à testes estatísticos adequados para cada tipo de análise. A VIO quando utilizado isoladamente proporcionou alterações cromáticas superficiais e em profundidade, mas seu efeito foi estatisticamente menor do que o proporcionado pelo gel clareador. Na fluorescência, o T1 e T3 do PH35%-SL foram diferentes. A difusão do PH e a permeabilidade dentária, ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Researchers have proposed tooth whitening only with the irradiation of violet light (VIO), without the need for whitening gel. Therefore, the objective of this study was to evaluate in vitro and in vivo this new treatment associated with different concentrations of hydrogen peroxide (PH) for its bleaching efficacy and possible adverse effects. For the in vitro study, 567 (n = 67) teeth were selected and divided into 9 groups: No Gel (SG) -Without Light (SL), PH17.5% -SL, PH35% -SL, SG-LED / Laser (LED), PH17.5% -LED, PH35% -LED, SG-VIO, PH17.5% -VIO, and PH35% -VIO. The application of the gels followed the manufacturer's recommendations. The LED was applied3 times 3 minutes, the VIO was applied3 times 7 minutes. After the bleaching procedures, superficial chromatic alteration and fluorescence intensity analyzes were performed (n = 10), considering 5 analysis times (initial T0, T1-1st session, T2-2nd session, T3-3th session, T4-14 days later), depth color change (n = 15), hydraulic conductance (n = 10), PH diffusion (n = 10), cell viability (n = 8) and intrapulp temperature variation (n = 10) ). Data were submitted to appropriate statistical tests for each type of analysis. VIO when used alone provided superficial and deep color changes, but its effect was statistically smaller than that provided by the whitening gel. In fluorescence, the T1 and T3 of PH35% -SL were different. PH diffusion and dental permeability, the PH35% groups presented the highest values, being potentiate... (Complete abstract click electronic access below) / Doutor
22

Avaliação clínica do efeito de dentifrícios clareadores na cor e rugosidade do esmalte dental e compósitos odontológicos / Clinical evaluation of color and surface roughness of dental enamel and dental composites submitted to brushing with whitening toothpaste

Roselino, Lourenço de Moraes Rego 11 August 2015 (has links)
Os objetivos deste estudo foram avaliar clinicamente a alteração de cor e de rugosidade de superfície do esmalte dental e de compósitos odontológicos, submetidos à escovação com dentifrícios clareadores e a ação deles sobre a degradação das pontas das cerdas da escova dental. Foram obtidos 30 corpos-de-prova (6mm de diâmetro X 2mm de espessura) de cada compósito (Z250 e Z350, 3M ESPE e Tetric N-Ceram, Ivoclar Vivadent). Em seguida, estes foram aleatoriamente fixados na face vestibular dos primeiros molares superiores (direito e esquerdo) e de um segundo molar superior (direito ou esquerdo) de 30 participantes selecionados para o estudo, de acordo com os critérios de inclusão determinados. Após a fixação dos espécimes, os participantes receberam escovas de dentes (Oral B Classic, Procter & Gamble) e dentifrício convencional (Sorriso Dentes Brancos, Colgate-Palmolive) e foram orientados a utilizar esses produtos durante 7 dias (período pré-experimental) após o qual foram realizadas as leituras iniciais de cor (Easyshade, VITA) e de rugosidade de superfície (Rugosímetro Surfcorder SE 1700, Kosakalab) das amostras e também do esmalte dental de um dos incisivos centrais superiores dos participantes. Para as leituras de rugosidade foi realizada moldagem (Express, 3M ESPE) do incisivo central superior e dos corpos-de-prova fixados para posterior obtenção de modelos com resina de poliuretano (Axon F16, Abcol) para confecção de réplicas, sobre as quais foram realizadas as leituras. Após as leituras iniciais, os participantes foram separados em 3 grupos (n=10), conforme o dentifrício clareador utilizado: Grupo 1) Dentifrício controle (Sorriso Dentes Brancos); Grupo 2) Dentifrício clareador (Colgate Luminous White, Colgate-Palmolive); e Grupo 3) Dentifrício clareador de ação rápida (Close up White Now, Unilever). As cerdas das escovas dentais utilizadas pelos participantes foram analisadas por MEV (Microscópio XL30 Field Emission Gun, Philips), em duas regiões da escova: periférica e central. Os períodos de análise da ação dos dentifrícios clareadores foram, 7, 30 e 90 dias. Os valores das medições (antes e após os períodos de testes) foram analisados estatisticamente (3-way-ANOVA, medidas repetidas, Tukey, p<0,05) e os resultados demonstraram que não houve alteração de cor significativa dos substratos analisados independentemente do tipo de dentifrício utilizado, mas o tempo de utilização de um dentifrício sobre os compósitos foi significante para a alteração de cor. Não houve alteração de rugosidade de superfície do esmalte dental, independente do dentifrício utilizado. A alteração de rugosidade de superfície dos compósitos é material dependente, mas o tempo de escovação com esses dentifrícios não interfere nessa propriedade. Quanto maior o tempo de escovação, maior o desgaste da ponta das cerdas da escova, independente do dentifrício utilizado e da região a que ela pertence. Conclui-se que a alteração de cor e de rugosidade de superfície dos compósitos é material-dependente e tempo-dependente para a alteração de cor e para degradação das cerdas da escova. / The aims of this study were to clinically evaluated the color change and the surface roughness of enamel and dental composites submitted to brushing with whitening toothpaste and the their action over the degradation of the tips of the bristles of the toothbrush. 30 specimens were obtained (6 mm diameter X 2mm thick) of each composite (Z250 and Z350, 3M ESPE and Tetric N-Ceram, Ivoclar Vivadent). Then, the specimens were randomly bonded on the maxillary first molars buccal surfaces (right and left sides) and the one maxillary second molar (right or left sides) of 30 participants, which were selected for the study according to inclusion criteria. After specimens bonding, participants received toothbrush (Oral B Classic, Procter & Gamble) and non whitening toothpaste (Sorriso Dentes Brancos, Colgate-Palmolive) and also they were instructed to use these products for 7 days (pre-trial). After that, were realized the initial color (Easyshade, VITA) and surface roughness (Roughness Surfcorder SE 1700, KosakaLab) readings of specimens and of the enamel of the maxillary central incisors of the participants. For surface roughness readings was performed molding (Express, 3M ESPE) of the maxillary central incisor and of the specimens fixed to be retrieved later of the models with polyurethane resin (Axon F16, Abcol). Then in these replicas were made surface roughness readings. After baseline measurements, participants were divided into 3 groups (n=10), according to the whitening toothpaste used: Group 1) Control toothpaste (Sorriso Dentes Brancos); Group 2) Whitening toothpaste (Colgate Luminous White, Colgate-Palmolive); and Group 3) Whitening toothpaste with fast action (Close up White Now, Unilever). The bristles of toothbrushes used by the participants were analyzed by SEM (Field Emission Gun Microscope XL30, Philips) in two regions of the brush: peripheral and central. The periods of action analysis of whitening toothpaste were 7, 30 and 90 days. The measured values (before and after the testing periods) were statistically analyzed (3-way ANOVA, repeated measures, Tukey, p <0.05) and the results showed no significant color change of the substrates analyzed independently of the type toothpaste used, but the time of use of a dentifrice over the composites was significant for the color change. There was no surface roughness change enamel independently of the toothpaste used. The surface roughness change of composites is dependent on material, but the time of brushing with these toothpaste does not interfere in this property. The longer the time of brushing, the greater the degradation in the tips of the bristles of the toothbrush independently of the toothpaste used and the region to which it belongs. It is conclude that the color change and surface roughness of the composites is material-dependent and time-dependent to color change and to degradation of the brush bristles.
23

Avaliação clínica do efeito de dentifrícios clareadores na cor e rugosidade do esmalte dental e compósitos odontológicos / Clinical evaluation of color and surface roughness of dental enamel and dental composites submitted to brushing with whitening toothpaste

Lourenço de Moraes Rego Roselino 11 August 2015 (has links)
Os objetivos deste estudo foram avaliar clinicamente a alteração de cor e de rugosidade de superfície do esmalte dental e de compósitos odontológicos, submetidos à escovação com dentifrícios clareadores e a ação deles sobre a degradação das pontas das cerdas da escova dental. Foram obtidos 30 corpos-de-prova (6mm de diâmetro X 2mm de espessura) de cada compósito (Z250 e Z350, 3M ESPE e Tetric N-Ceram, Ivoclar Vivadent). Em seguida, estes foram aleatoriamente fixados na face vestibular dos primeiros molares superiores (direito e esquerdo) e de um segundo molar superior (direito ou esquerdo) de 30 participantes selecionados para o estudo, de acordo com os critérios de inclusão determinados. Após a fixação dos espécimes, os participantes receberam escovas de dentes (Oral B Classic, Procter & Gamble) e dentifrício convencional (Sorriso Dentes Brancos, Colgate-Palmolive) e foram orientados a utilizar esses produtos durante 7 dias (período pré-experimental) após o qual foram realizadas as leituras iniciais de cor (Easyshade, VITA) e de rugosidade de superfície (Rugosímetro Surfcorder SE 1700, Kosakalab) das amostras e também do esmalte dental de um dos incisivos centrais superiores dos participantes. Para as leituras de rugosidade foi realizada moldagem (Express, 3M ESPE) do incisivo central superior e dos corpos-de-prova fixados para posterior obtenção de modelos com resina de poliuretano (Axon F16, Abcol) para confecção de réplicas, sobre as quais foram realizadas as leituras. Após as leituras iniciais, os participantes foram separados em 3 grupos (n=10), conforme o dentifrício clareador utilizado: Grupo 1) Dentifrício controle (Sorriso Dentes Brancos); Grupo 2) Dentifrício clareador (Colgate Luminous White, Colgate-Palmolive); e Grupo 3) Dentifrício clareador de ação rápida (Close up White Now, Unilever). As cerdas das escovas dentais utilizadas pelos participantes foram analisadas por MEV (Microscópio XL30 Field Emission Gun, Philips), em duas regiões da escova: periférica e central. Os períodos de análise da ação dos dentifrícios clareadores foram, 7, 30 e 90 dias. Os valores das medições (antes e após os períodos de testes) foram analisados estatisticamente (3-way-ANOVA, medidas repetidas, Tukey, p<0,05) e os resultados demonstraram que não houve alteração de cor significativa dos substratos analisados independentemente do tipo de dentifrício utilizado, mas o tempo de utilização de um dentifrício sobre os compósitos foi significante para a alteração de cor. Não houve alteração de rugosidade de superfície do esmalte dental, independente do dentifrício utilizado. A alteração de rugosidade de superfície dos compósitos é material dependente, mas o tempo de escovação com esses dentifrícios não interfere nessa propriedade. Quanto maior o tempo de escovação, maior o desgaste da ponta das cerdas da escova, independente do dentifrício utilizado e da região a que ela pertence. Conclui-se que a alteração de cor e de rugosidade de superfície dos compósitos é material-dependente e tempo-dependente para a alteração de cor e para degradação das cerdas da escova. / The aims of this study were to clinically evaluated the color change and the surface roughness of enamel and dental composites submitted to brushing with whitening toothpaste and the their action over the degradation of the tips of the bristles of the toothbrush. 30 specimens were obtained (6 mm diameter X 2mm thick) of each composite (Z250 and Z350, 3M ESPE and Tetric N-Ceram, Ivoclar Vivadent). Then, the specimens were randomly bonded on the maxillary first molars buccal surfaces (right and left sides) and the one maxillary second molar (right or left sides) of 30 participants, which were selected for the study according to inclusion criteria. After specimens bonding, participants received toothbrush (Oral B Classic, Procter & Gamble) and non whitening toothpaste (Sorriso Dentes Brancos, Colgate-Palmolive) and also they were instructed to use these products for 7 days (pre-trial). After that, were realized the initial color (Easyshade, VITA) and surface roughness (Roughness Surfcorder SE 1700, KosakaLab) readings of specimens and of the enamel of the maxillary central incisors of the participants. For surface roughness readings was performed molding (Express, 3M ESPE) of the maxillary central incisor and of the specimens fixed to be retrieved later of the models with polyurethane resin (Axon F16, Abcol). Then in these replicas were made surface roughness readings. After baseline measurements, participants were divided into 3 groups (n=10), according to the whitening toothpaste used: Group 1) Control toothpaste (Sorriso Dentes Brancos); Group 2) Whitening toothpaste (Colgate Luminous White, Colgate-Palmolive); and Group 3) Whitening toothpaste with fast action (Close up White Now, Unilever). The bristles of toothbrushes used by the participants were analyzed by SEM (Field Emission Gun Microscope XL30, Philips) in two regions of the brush: peripheral and central. The periods of action analysis of whitening toothpaste were 7, 30 and 90 days. The measured values (before and after the testing periods) were statistically analyzed (3-way ANOVA, repeated measures, Tukey, p <0.05) and the results showed no significant color change of the substrates analyzed independently of the type toothpaste used, but the time of use of a dentifrice over the composites was significant for the color change. There was no surface roughness change enamel independently of the toothpaste used. The surface roughness change of composites is dependent on material, but the time of brushing with these toothpaste does not interfere in this property. The longer the time of brushing, the greater the degradation in the tips of the bristles of the toothbrush independently of the toothpaste used and the region to which it belongs. It is conclude that the color change and surface roughness of the composites is material-dependent and time-dependent to color change and to degradation of the brush bristles.
24

Avaliação de agentes remineralizadores e dessensibilizantes no tratamento de clareamento dental: estudo in vitro / Evaluating remineralizing and desensitizing agents in dental bleaching treatment: in vitro study

Pintado Palomino, Karen 15 August 2013 (has links)
O objetivo deste estudo foi avaliar comparativamente, in vitro, o efeito de agentes remineralizadores e dessensibilizantes na rugosidade superficial e microdureza do esmalte e dentina bovina exposta a peróxido de carbamida a 16% (T1) ou peróxido de hidrogênio a 35% (T2). Os agentes clareadores T1 e T2 conjuntamente com os agentes remineralizadores/ dessensibilizantes - dentifrício Sensodyne® (D1); dentifrício experimental com 7,5% de micro-partículas de Biosilicato® (D2); dentifrício Odontis RX® (D3); dentifrício Sorriso® (D4); pasta experimental com micropartículas de Biosilicato® (D5); Desensebilize Nano P® (D6); pasta experimental com micropartículas de Bioglass® tipo 45S5 (D7); água destilada (GC) - foram usados considerando os grupos experimentais: T1/D1; T1/D2; T1/D3; T1/D4; T1/D5; T1/D6; T1/D7; T1/GC e T2/D1; T2/D2; T2/D3; T2/D4; T2/D5; T2/D6; T2/D7; T2/GC. Análise de rugosidade superficial (Ra), microdureza e imagens em microscopia eletrônica de varredura (MEV) foram realizadas antes (t0) e após (t1) o tratamento com os géis clareadores (T1= 14 dias/ 4h por dia; T2= sessão única) e os produtos remineralizadores/dessensibilizantes. Os dados colhidos foram analisados intra e intergrupos, estatisticamente por meio de Análise de Variância e Teste de Tukey. Os resultados mostraram que na rugosidade superficial não houve diferença significante (p>0.05) entre a rugosidade inicial (t0) e final (t1) tanto no esmalte quanto na dentina. A microdureza diminuiu nas amostras de dentina para o grupo T1/D6 (t0=40,99/ t1=29,11) e foi aumentada nas amostras de esmalte do grupo T1/D1 (t0=255,0/ t1=318,1). Conclui-se que o tratamento com peróxido de carbamida a 16% ou peróxido de hidrogênio a 35% associado aos agentes dessensibilizante/remineralizantes avaliados neste estudo não alteraram a rugosidade superficial do esmalte e dentina bovina, no entanto a microdureza pode ser alterada quando o peróxido de carbamida a 16% é usado. / This study aimed to evaluate in vitro the effect of remineralizing and desensitizing agents on microhardness (MH) and roughness (RG) enamel and dentin bovine samples exposed to 16% carbamide peroxide (T1) or 35% hydrogen peroxide (T2). Dental bleaching agents - T1 and T2 - together with desensitizing/ remineralizing agents - Sensodyne® dentifrice (D1); experimental dentifrice containing 7,5% micron-sized particles of Biosilicate® (D2); Odontis RX® dentifrice (D3); Sorriso® dentifrice (D4); microsized particles of Biosilicate® paste (D5); Dessensebilize Nano P® (D6); Bioglass® type 45S5 paste (D7); distilled water (CG) were used according to the experimental groups: T1/D1; T1/D2; T1/D3; T1/D4; T1/D5; T1/D6; T1/D7; T1/GC and T2/D1; T2/D2; T2/D3; T2/D4; T2/D5; T2/D6; T2/D7; T2/CG. MH, RG measurements, and images using scanning electron microscopy (SEM) were made on the samples before (t0) and after (t1) the treatment with the bleaching gels (T1= 14 days/ 04 hours/day; T2=single session) and the desensitizing/remineralizing agents. Data was analyzed statistically with One way-ANOVA and posterior Tukey Test. RG evaluation revealed no significant difference (p>0.05) between baseline (t0) and final (t1) RG for all experimental groups. MH decreased in dentine samples for T1/D6 (t0=40,99/ t1=29,11) and increased in enamel samples for T1/D1 (t0=255,0/ t1=318,1). It was concluded that the treatment with carbamide peroxide at 16% or hydrogen peroxide at 35% in combination with desensitizing/ remineralizing agents didnt alter enamel and dentin surface roughness; however microhardness could be affected when peroxide carbamide at 16 % is used.
25

Efeito do protocolo clareador na degradação, alteração de pH, eficácia e segurança do gel de peróxido de hidrogênio /

Abreu, Fabrícia Stabile de Abreu. January 2019 (has links)
Orientador: Alessandra Bühler Borges / Coorientadora: Rayssa Ferreira Zanatta / Banca: Cesar Rogério Pucci / Banca: Daniele Mara da Silva Ávila Nogueira / Resumo: O objetivo deste estudo foi avaliar a degradação do peróxido de hidrogênio em altas concentrações (35-40%), durante uma simulação de sessão de clareamento de consultório, utilizando produtos comercialmente disponíveis com dois protocolos de aplicação. Foram medidas também a eficácia clareadora dos géis, a alteração de pH dos mesmos, bem como o potencial de alteração da microdureza e rugosidade superficial do esmalte. Para tal, espécimes de dentes bovinos em forma de disco com 4 mm de diâmetro e 2 mm de espessura (1 mm de esmalte e 1 mm de dentina) foram preparados para tal 105 espécimes, embutidos em resina acrílica, polidos e divididos nos seguintes grupos, de acordo com o tipo de gel clareador: Pola Office Plus (POP - SDI PH-37,5%), Opalescence Boost (OPB - Ultradent PH-40%) e Whiteness HP (WHP - FGM PH-35%). Cada grupo foi dividido em dois subgrupos conforme o protocolo de aplicação (n = 15): com e sem troca do gel clareador durante a sessão de clareamento. A alteração de cor das amostras foi medida por espectrofotometria de acordo com o sistema CIE L*a*b*, antes e após a sessão de clareamento. A superfície do esmalte foi analisada com microdurômetro e perfilômetro, para mensuração da microdureza Knoop (KHN) e rugosidade superficial (Ra). Outros 30 espécimes adicionais em dentes bovinos foram confeccionados para mensuração da concentração do peróxido de hidrogênio e pH. A concentração e pH dos géis foram medidos por meio da titulação com permanganato de potássio (KMnO4) e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the degradation of hydrogen peroxide at high concentrations (35-40%) during a clinic whitening session simulation using commercially available products with two application protocols. The bleaching efficiency of the gels, pH change, as well as the alteration potential of the enamel microhardness and surface roughness (Ra) were measured. For this, disc-shaped bovine tooth specimens of 4 mm diameter and 2 mm thickness (1 mm enamel and 1 mm dentin) were prepared 105 specimens, embedded in acrylic resin, polished, and divided into the following groups according to the type of bleaching gel: Pola Office Plus (POP - SDI PH-37,5%), Opalescence Boost (OPB - Ultradent PH-40%), and Whiteness HP (WHP - FGM PH-35%). Each group was divided into two subgroups, according to the application protocol (n = 15): with and without exchange of the gel during the whitening session. The specimens' color change was measured by spectrophotometry according to the CIE system L*a*b*, before and after the bleaching session. The enamel surface was analyzed with a microhardner and profilometer, to measure the Knoop microhardness and surface roughness (Ra). Another 30 specimens in bovine teeth were made to measure the hydrogen peroxide concentration and pH. The concentration and pH of the gels were measured by titration with potassium permanganate (KMnO4) and by a pH meter and specific electrode, respectively, before and after said application times thereof. The degradation of the gels was calculated as a function of the initial concentration. The results were submitted to the ANOVA test and Tukey's multiple comparison test (5%). All gels presented similar bleaching efficacy (ΔE and ΔE00) comparing SA and MA. There were no significant differences between KHN and Ra means comparing SA and MA for the same gel. Although peroxide degradation significantly increased with time, the final gels concen.. / Mestre
26

Clareamento caseiro utilizando moldeiras padronizadas pré-carregadas comparado com moldeiras personalizadas : estudo clínico randomizado /

Mailart, Mariane Cintra. January 2017 (has links)
Orientador: Alessandra Bühler Borges / Banca: Carlos Rocha Gomes Torres / Banca: Roberta Tarkany Basting Höfling / Resumo: O objetivo deste estudo clínico randomizado foi avaliar a eficácia do clareamento caseiro com moldeira padronizada pré-carregada (MC) comparado à moldeira personalizada (MP), quanto à alteração de cor; condição gengival; sensibilidade dental; desmineralização do esmalte e satisfação do paciente. Foram testados géis clareadores à base de peróxido de hidrogênio (PH) a 10% e peróxido de carbamida (PC) a 10%. Quarenta e cinco voluntários foram recrutados e divididos aleatoriamente em três grupos de tratamento: OGO (Opalescence Go - PH a 10% na MC); OPF (Opalescence PF - PC a 10% na MP) e WTC (White Class - PH a 10% na MP). O clareamento foi realizado 1x/dia por 14 dias durante 2 h para o PC e 30 min para o PH. A cor dos dentes foi avaliada visualmente com as escalas Vitapan Classical (VC) e Vita Bleachedguide 3D-MASTER (VB) e com espectrofotômetro. A sensibilidade dental foi avaliada com escala numérica associada à escala visual análoga; a condição gengival pelo índice de Löe; o grau de mineralização do esmalte dental pela irradiação com laser fluorescente e a satisfação do paciente por um questionário. As avaliações foram realizadas em diferentes momentos do tratamento. Os dados de cor foram submetidos ao teste ANOVA de medidas repetidas e teste de comparações múltiplas de Tukey (5%). Tanto para sensibilidade (SD), quanto para a inflamação gengival (IG), o risco absoluto foi calculado com o teste exato de Fisher e para comparação da intensidade entre os grupos, ANOVA medidas rep... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this randomized clinical trial is to evaluate the performance of at-home bleaching with universal prefilled whitening trays (PT) compared with customized trays (CT) regarding tooth bleaching, gingival condition, tooth sensitivity, enamel demineralization and volunteer satisfaction. 10% Hydrogen peroxide (HP) and 10% carbamide peroxide (CP) peroxide-based gels were tested. Forty five volunteers were recruited and randomly divided into three treatment groups: OGO (Opalescence Go - 10% HP in PT); OPF (Opalescence PF - 10%CP in CT) and WTC (White Class - 10% HP in CT). The bleaching treatment were accomplished 1x/day for 14 days, during 2 h for CP and 30 min for HP. The teeth shades were evaluated visually using the shade guides Vitapan Classical (VC) and Vita Bleachedguide 3D-MASTER (VB), and spectrophotometrically. The tooth sensitivity were evaluated using a numeric scale associated with a visual analogue scale; the gingival condition with the Löe's index; the enamel demineralization with a fluorescent laser irradiation and volunteer satisfaction with a questionnaire. The evaluations were performed in different moments of the treatment. Data of tooth bleaching were submitted to ANOVA repeated measures and Tukey's multiple comparison test (5%). For both tooth sensitivity (TS) and gingival inflammation (GI), the absolute risk was calculated using Fisher's exact test and for intensity comparison among the groups, ANOVA repeated measures for TS and Kruskal-Wallis for GI... (Complete abstract click electronic access below) / Mestre
27

Avaliação do efeito de diferentes agentes clareadores na rugosidade superficial e estabilidade de cor de dois compósitos / In vitro evaluation of different bleaching agents on the roughness and color stability of two dental composites

Anna Paula Kalix França Mendes 13 February 2009 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar, in vitro, o efeito de dois clareadores a base de peróxido de hidrogênio a 10% e a 35%, Rembrandt Whitening Pen/Oral B e Whiteness HP Maxx/FGM na estabilidade de cor e rugosidade superficial de dois compósitos, sendo um nanohíbrido TPH3/ Dentsply e outro nanoparticulado Filtek Z350/3M ESPE. Foram confeccionados 40 corpos de prova a partir de uma matriz de aço inox com dimensões de 21,0 mm de diâmetro e 2,00 mm de profundidade e divididos em dois grupos conforme o compósito a ser avaliado e submetidos aos seguintes experimentos: Exp. I Ação dos agentes clareadores na estabilidade de cor dos compósitos; Exp. II - Ação dos agentes clareadores na rugosidade superficial dos compósitos; Exp. III - Ação do polimento de superfície na rugosidade superficial e retomada de cor dos compósitos. Tanto a rugosidade como a estabilidade de cor foi avaliada em rugosímetro Mitutoyo SJ 201P e Espectofotômetro de Reflectância Perkin Elmer Lambda 35 UV/VIS respectivamente durante as seguintes etapas do experimento: T0 - após a confecção dos corpos de prova, T1 - após envelhecimento acelerado das amostras por 24 horas por luz ultravioleta, T2 - após submetidas a dois corantes: café e açaí por 7 dias, T3 - após submetidas aos agentes clareadores e T4- após polimento das mesmas. Durante todo o experimento os corpos de prova foram mantidos em saliva artificial e estufa calibrada a 37oC. Os resultados foram tratados estatisticamente por ANOVA e testes de Tukey, comparações múltiplas de Bonferroni e SNK com 5% de significância. Não foram observadas diferenças estatisticamente significantes entre os corantes, o mesmo acontecendo quando os clareadores foram comparados por Teste-t de Student com 5% de significância. Baseado nos resultados obtidos pôde-se concluir que o compósito TPH3 foi mais afetado pelos corantes que o compósito Z350. Os agentes clareadores não foram capazes de promover clareamento dos compósitos nos tempos testados, porém o polimento possibilitou retorno à condição de cor inicial (envelhecida) para o compósito TPH3 o mesmo não acontecendo para o Z350. O polimento não determinou retorno à condição original de rugosidade para qualquer dos compósitos. / The objective of this study was to evaluate, in vitro, the effects of two commercially available bleaching agents containing hydrogen peroxide, Rembrandt Whitening Pen/Oral B and Whiteness HP Maxx/FGM, on the surface roughness and on color change of two composites (TPH3/Dentsply and Filtek Z350/3M ESPE). Twenty specimens of each material were constructed by using a stainless matrix, measuring 21.0 mm diameter and 2.00 mm depth and divided in three groups according the experiments. Group I- effect of the bleaching agents on the composites color change; Group II- effect of the bleaching agents on surface roughness; Group III- effect of polishing procedures on the surface roughness and on color change of the composites. The color measurements were done using a reflectance spectrophotometer Perkin Elmer Lambda 35 UV/VIS according to the CIE L*a*b* color scale and the roughness measurements were obtained using a digital Mitutoyo rugosimeter SJ 201P. The measurements were made in five times: T0: after the specimen preparation; T1: after accelerated aging for 24 hours UV light; T2: after immersed for 07 days at 37o C in either coffee or açaí (a typical fruit of North of Brazil); T3: after bleaching procedures and T4: after finishing and polishing. The results were statistical treated by ANOVA and the differences treated by Tukey, Bonferroni`s test and SNK with 5% of significance. According t-Test with 5% of significance, there were no differences between the staining (coffee and açaí) and neither between the bleaching agents tested. The composite TPH3 showed higher values of discoloration when compared with Filtek Z350, The bleaching agents were not able to improve any kind of whitening on the composites surface. The polishing procedures after bleaching were effective on return the TPH3 to its original color, but they were not capable to return the original roughness of both of the composites.
28

Ação de enxaguatórios clareadores e sua associação ao clareamento caseiro com peróxido de carbamida / Efficacy of whitening mouthrinses and association to home bleaching with carbamide peroxide

Oliveira, Juliana Boa Sorte de [UNESP] 13 January 2016 (has links)
Submitted by JULIANA BOA SORTE DE OLIVEIRA null (grc@unesp.br) on 2016-03-16T06:46:22Z No. of bitstreams: 1 Dissertação - Juliana Boa Sorte.pdf: 1304673 bytes, checksum: dde4b206040aaf2ec3e5e04e1bf030eb (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-03-18T12:55:01Z (GMT) No. of bitstreams: 1 oliveira_jbs_me_sjc.pdf: 1304673 bytes, checksum: dde4b206040aaf2ec3e5e04e1bf030eb (MD5) / Made available in DSpace on 2016-03-18T12:55:01Z (GMT). No. of bitstreams: 1 oliveira_jbs_me_sjc.pdf: 1304673 bytes, checksum: dde4b206040aaf2ec3e5e04e1bf030eb (MD5) Previous issue date: 2016-01-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivos: o objetivo deste estudo foi comparar a efetividade de enxaguatórios clareadores sobre dentes, clareados previamente ou não, expostos a corantes alimentícios. Material e Método: Cento e vinte espécimes de esmalte e dentina de 3 mm de diâmetro foram obtidos a partir de incisivos bovinos. Os espécimes foram manchados por 14 dias em caldo de manchamento. Após o manchamento, a leitura inicial da cor foi realizada, por meio do espectrofotômetro CM-2600d (Konica Minolta, Osaka, Japão). Sessenta espécimes (Subgrupos PC) foram submetidos ao clareamento com Peróxido de Carbamida a 10% por 14 dias. Após, foram subdividos em 4 subgrupos, com ciclos de manchamento (5 min) e enxaguatório (2 min) por 12 semanas, sendo PC-LI: Listerine Whitening Pré-escovação; PC-PL: Plax Whitening; PC-BP: Bromelina + Papaína; PC-AG: água deionizada. Os subgrupos LI, PL, BP e AG foram submetidos aos mesmos ciclos citados, porém não foram submetidos ao clareamento prévio. A leitura de cor dos espécimes foi feita após 4, 8 e 12 semanas de tratamento com os enxaguatórios. Os dados foram coletados e submetidos à Análise de variância (ANOVA) de medidas repetidas. A comparação entre os subgrupos para a avaliação das diferenças estatísticas foi realizada pelo Teste de Tukey. Todos os testes empregados admitiram 5% como nível de significância estatística. Os resultados mostraram que os valores de ΔL*, Δa*, Δb* e ΔE* confirmaram o clareamento para os subgrupos PC-LI, PC-PL, PC-BP e PC-AG, após o tratamento com peróxido de carbamida, e para os subgrupos PC-LI, PC-PL, LI e PL, após os ciclos manchamento-enxaguatório. Os subgrupos PC-BP e BP assemelharam-se aos subgrupos controle PC-AG e AG. Conclui-se, desse modo, que o enxaguatório bucal Listerine Whitening apresentou maior efeito clareador, seguido do enxaguatório Plax Whitening. Porém, nenhum desses enxaguatórios foi capaz de produzir clareamento semelhante ao evidenciado pelo Peróxido de Carbamida. O enxaguatório contendo Bromelina e Papaína em sua composição não evidenciou efeito clareador, assemelhando-se aos subgrupos controle. / Objectives: The aim of this study was to compare the effectiveness of whitening mouthrinses on teeth previously whitened or not, exposed to food dyes. Material and Methods: One hundred and twenty specimens of enamel and dentin of 3 mm in diameter were obtained from bovine incisors. The specimens were stained for 14 days in broth staining. After staining, the initial color reading was performed by a spectrophotometer CM-2600d (Konica Minolta, Osaka, Japan). Sixty specimens (Subgroups CP) were submitted to whitening (Carbamide Peroxide 10%) for 14 days. Then they were subdivided into 3 subgroups, and were submitted to cycles of staining (5 min) and mouthrinse (2 min) for 12 weeks, with CP-LI: Listerine Whitening Pré-Escovação; CP-PL: Plax Whitening; CP-BP: Bromelain + Papain; CP-DW: deionized water. LI, LP, BP and DW subgroups were submitted to the same cited cycles, but without bleaching before. The color measurements were performed after 4, 8 and 12 weeks of treatment with mouthrinses. Data were collected and subjected to analysis of variance (ANOVA) for repeated measures. The comparison between the subgroups for the evaluation of statistical differences was performed by Tukey test. All tests admitted statistical significance level of 5%. The results showed that the values ΔL*, Δa*, Δb* and ΔE* confirmed bleaching to PC-LI, PC-PL, PC-BP and PC-DW subgroups, after treatment with carbamide peroxide and to CP-LI, CP-PL, LI and PL subgroups, after the staining-mouthrinse cycles. CP-BP and BP subgroups were similar to CP-DW and DW. We conclude, therefore, that the mouthrinse Listerine Whitening presented the highest bleaching effect, followed by mouthrinse Plax Whitening. Both of them were able to maintain the bleaching effect of CP after 12 weeks of dye-rinse cycles. However, none of these rinses was able to produce whitening similar to that evidenced by the Carbamide Peroxide. The mouthrinse containing Bromelain and Papain in its composition did not show bleaching effect, resembling the control subgroups.
29

INFLUÊNCIA DE AGENTES CLAREADORES NA COR DE RESINAS COMPOSTAS DE DIFERENTES OPACIDADES ARMAZENADAS EM MEIOS DISTINTOS / EFFECT OF BLEACHING AGENTS ON COLOR OF COMPOSITE RESINS WITH DISTINCT OPACITYS STORED IN DIFERENT MEDIAS

Lago, Maristela 26 March 2012 (has links)
The aim of this study was to evaluate the influence of two bleaching agents on color of one composite resin (Filtek Z350 XT - 3M ESPE) in the opacities of enamel and dentin, previously subjected to the action of deionized water or red wine. Sixty specimens (sp) were made for each composite resin using a metal matrix with 8 mm diameter and 2 mm thickness. Immediately after polymerization with LED (Emitter Schuster / Santa Maria Rio Grande do Sul, Brasil) for 40 s, the sp were polished with Diamond Pro discs (FGM / Joinvile SC, Brasil), and felt discs with diamond paste (Diamond Excel FGM / Joinvile SC, Brasil), then sp were washed in water and dried. The sp were divided into two groups for each opacity: immersed in red wine or deionized water for 14 days and then divided into three subgroups: one group subjected to bleaching with hydrogen peroxide 35% (Mix One Lot: 043 - Dental Villevie Brasil Ltda), one group submitted to bleaching with carbamide peroxide 16% (Mix Night - Lot: 007 - Dental Villevie Brasil Ltda) and one group not subjected to bleaching. Successive measurements were conducted 24 hours after polishing procedures, after 14 days of immersion on their respective immersion media, and after the action of the bleaching agents, using a spectrophotometer (SP60 EX-Rite / Grand Rapid Michigan, USA), with CIE L* a* b* system. Data were analyzed with t-test, one-way ANOVA, and Tukey (5%). Red wine caused significant color change in the composites in relation to water, and the enamel resin presented greater color change than the dentin resin. Bleaching agents partially removed the pigmentation of the sp which were immersed in wine, and the carbamide peroxide showed more significant results. The bleaching agents did not determine significant results when the sp were immersed in water. Red wine had great influence on the color change of composite resins and water caused no significant color change. The bleaching agents were capable of partial removal of the pigmentation produced by red wine. / Este trabalho teve por objetivo avaliar a influência de dois agentes clareadores sobre a cor de uma resina composta (Filtek Z350 XT 3M ESPE) nas opacidades de esmalte e dentina, previamente submetidas à ação de água deionizada ou vinho tinto suave. Foram confeccionados 60 corpos-de-prova (cps) para cada resina composta utilizando uma matriz metálica com 8 mm de diâmetro e 2 mm de espessura. Imediatamente após a fotoativação com um LED (Emitter Schuster / Santa Maria Rio Grande do Sul, Brasil) por 40s, os cps foram polidos com discos Diamond Pro (FGM / Joinvile SC, Brasil) e disco de feltro com pasta diamantada (Diamond Excel FGM / Joinvile SC, Brasil), lavados em água e secos. Os cps foram divididos em 2 grupos para cada opacidade: imersos em vinho tinto suave ou em água deionizada, por 14 dias e subdivididos em 3 subgrupos: um grupo submetido ao clareamento com peróxido de hidrogênio 35% (Mix One Lot: 043 - Dental Villevie Brasil Ltda), um grupo submetido ao clareamento com peróxido de carbamida 16% (Mix Night - Lot: 007 - Dental Villevie Brasil Ltda) e um grupo não submetido ao clareamento. Sucessivas leituras foram realizadas após 24 horas da confecção dos corpos-de-prova (inicial), após 14 dias de imersão nos respectivos meios; e após a ação de agentes clareadores utilizando um espectrofotômetro (SP60 EX-Rite / Grand Rapid Michigan, USA), com o sistema CIE L* a* b*. Os dados foram submetidos ao Teste t, análise de variância uma via e Tukey (5%). O vinho tinto suave causou significativa alteração de cor nas resinas compostas em relação à água, sendo que, a resina composta de esmalte sofreu maior alteração de cor que a de resina composta de dentina. Os agentes clareadores removeram parcialmente o pigmento dos cps que foram imersos em vinho, sendo que o peróxido de carbamida apresentou resultados mais significativos. Já quando os cps foram imersos em água os agentes clareadores não determinaram resultados relevantes. O vinho tinto suave teve grande influência na alteração de cor das resinas compostas e a água não causou alteração de cor significativa. Os géis clareadores foram capazes de fazer a remoção parcial da pigmentação produzida pelo vinho tinto.
30

Avaliação da citotoxicidade de agentes clareadores para uso caseiro e profissional

Cardoso, Paula Elaine [UNESP] 26 August 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-08-26Bitstream added on 2014-06-13T20:22:21Z : No. of bitstreams: 1 cardoso_pe_dr_sjc.pdf: 421203 bytes, checksum: 78d99972a840d87b24c7feb43f8fd9db (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A proposta deste estudo foi avaliar a citotoxicidade dos peróxidos de hidrogênio (PH) e carbamida (PC), para uso caseiro e profissional, sobre cultura de fibroblastos de mucosa de tecido gengival humano (FMM1). As células utilizadas foram cultivadas em DMEM e após 24 horas foi colocado meio de cultivo condicionado com os agentes clareadores: G1- PC 35% sem fotoativação (SF); G2- PC 35% ativado por luz halógena; G3- PC 35% ativado por diodo emissor de luz (LED); G4- PC 37% SF; G5- PC 37% ativado por luz halógena; G6- PC 37% ativado por LED; G7- PH 3% SF; G8- PH 7,5% SF; G9- PH 9,5% SF; G10- PC 10% SF; G11- PC 15% SF e G12- PC 20% SF. Uma curva padrão de viabilidade celular foi obtida a partir de células que não receberam tratamento (controle). O ensaio com MTT foi realizado após 24 e 48 horas, para avaliar a viabilidade celular. Paralelamente, foi medido colorimetricamente a quantidade de PH liberado nas condições experimentais. Os dados da viabilidade celular obtidos foram analisados estatisticamente através dos testes ANOVA e Tukey, (p<0,05). Todos os grupos apresentaram diferença significativa em relação ao controle. Dentre os agentes clareadores para uso profissional o PC 37% apresentou maior citotoxicidade e quantidade de peróxido de hidrogênio liberada que o PC 35%. A ativação por luz halógena ocasinou maior citotoxicidade e maior quantidade de PH liberado. Dentre os agentes clareadores para uso caseiro a base de peróxido de hidrogênio houve uma maior taxa de sobrevivência celular na concentração mais baixa de peróxido de hidrogênio (PH 3%); nos clareadores a base de peróxido de carbamida houve uma maior taxa de sobrevivência celular na concentração mais baixa de peróxido de carbamida (PC 10%). A taxa de sobrevivência celular foi significantemente menor após 48 horas. Concluiu-se que a citotoxicidade foi proporcional à concentração... / The purpose of this study was to evaluate the citotoxicity of hydrogen peroxide (HP) and carbamide peroxide (CP) on fibroblasts from mucosa of human gingival tissue (FMM1). The cells were cultivated in DMEM and was placed in contact with conditioned medium with bleaching agents: G1- 35% CP without curing, G2-35% CP activated by halogen light; G3- 35% CP activated by light emission diode (LED); G4- 37% CP without curing; G5- 37% CP activated by halogen lamp; G6- 37% CP activated by LED; G7- 3% HP without curing; G8- 7.5% HP without curing; G9 - 9.5% HP without curing; G10- 10% CP without curing, G11-15% CP without curing, and G12- 20% CP without curing. A standard curve of cell growth and viability was obtained from cells that received no treatment (control). The MTT test was performed after 24 and 48 hours to assess the viability and cell growth. In parallel, was measured the amount of PH released under the experimental conditions. The data of cell viability were statistically analyzed by ANOVA and Tukey’s tests (p <0.05). All groups showed significant differences in relation to the control group. Among the bleaching agents for office application, the 37% CP showed higher cytotoxicity and the 35% CP released the higher quantity of hydrogen peroxide. The activation by halogen light promoted the higher cytotoxicity and higher HP released. Among the home bleaching agents based on hydrogen peroxide there was a higher rate of cell survival in low concentration of hydrogen peroxide (3% HP); the bleaching based on carbamide peroxide had a higher cell survival rate in low concentration of carbamide peroxide (CP 10%). The cell viability was significantly lower after 48 hours. It was concluded that the cytotoxicity was related to the concentration of bleaching agent and the curing with halogen light increased the hydrogen peroxide release.

Page generated in 0.0401 seconds