• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 7
  • 7
  • 7
  • 7
  • 6
  • 1
  • 1
  • 1
  • Tagged with
  • 21
  • 21
  • 14
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Citotoxicidade, produção de espécies reativas de oxigênio, expressão de marcadores celulares e produção de TNFα em macrófagos após exposição a agentes clareadores /

Fernandes, Aletéia Massula de Melo. January 2013 (has links)
Orientador: Marcia Carneiro Valera / Co-orientador: Samira Esteves Afonso Camargo / Banca: Ana Paula Martins Gomes / Banca: Bruno das Neves Cavalcanti / Banca: Renato de Toledo Leonardo / Banca: Renato Miotto Palo / Resumo: O objetivo deste estudo foi avaliar a citotoxicidade, produção de espécies reativas de oxigênio, análise de marcadores celulares e presença de TNFα em macrófagos após exposição a agentes clareadores. Foram utilizadas culturas celulares de macrófagos RAW 264.7 expostas a dois géis clareadores: Peróxido de hidrogênio 40% e Peróxido de Carbamida 20% e ao Peróxido de Hidrogênio puro (10%) que atuou como controle positivo, em diversos períodos de avaliação. Esses clareadores foram utilizados sozinhos e aditivados à NAC e ao BSO. A viabilidade celular foi determinada pelo ensaio MTT, assim como a sobrevivência celular foi avaliada pelo ensaio cristal violeta. A liberação de espécies reativas de oxigênio foi mensurada utilizando uma sonda fluorescente sensível a oxidação-H2DCF-D. Para a verificação da presença dos marcadores celulares CD14, CD40 e CD54, envolvidos no processo inflamatório e na resposta imune, foi utilizada a citometria de fluxo, enquanto que a produção de TNFα foi quantificada por ELISA. A análise estatística foi realizada através do teste Mann-Whitney com nivel de significancia a 5%. Os resultados obtidos permitiram concluir que: todos os peróxidos diminuiram a viabilidade e a sobrevivência celular, sendo a toxicidade desses clareadores porporcional às suas concentrações; todos os peróxidos estimularam a produção de ROS, sendo que a NAC apresentou tendência a diminuir essa produção, enquanto que o BSO apresentou efeito oposto; a expressão dos marcadores celulares foram aumentadas pelo uso do LPS, sendo o marcador mais expresso o CD54, seguido pelo CD40 e CD14; a estimulação por LPS aumentou a produção de TNFα e os peróxidos tiveram a tendência a aumentar essa produção / Abstract: The aim of this study was to evaluate the cytotoxicity, production of reactive oxygen species, analysis of cellular markers and the presence of TNFa in macrophages after exposure to bleaching agents. Cultures of RAW 264.7 macrophages were exposed to two bleaching gels: 40% Hydrogen Peroxide 20% Carbamide Peroxide; 10% pure Hydrogen Peroxide served as positive control, in different periods. These bleaching agents were used alone and associated with NAC and BSO. Cell viability was determined by MTT assay, and cell survival was assessed by crystal violet assay. The release of reactive oxygen species was measured using a fluorescent probe sensitive to oxidation-H2DCF-D. To verify the presence of the surface markers CD14, CD40, and CD54, involved in the inflammatory and immune response, it was used a flow cytometry, while the production of TNFa was measured by ELISA. Statistical analysis was performed using the Mann-Whitney test with a significance level of 5%. Results conclued that: all peroxides decreased the viability and cell survival, and toxicity of these bleaching was in proportion to their concentrations; all peroxides stimulated ROS production, and NAC showed a tendency to reduce this production while the BSO showed the opposite effect; the expression of surface markers were increased by the use of LPS, and the more expressed surface markers was the CD54, followed by CD40 and CD14; LPS stimulation increased the production of TNFα and peroxides had the tendency to increase this production, with the exception of higher concentrations, where most of the cells were dead / Doutor
2

Avaliação in vitro do efeito da escovação com dentifrícios clareadores sobre a superfície dentinária / In vitro evaluation of the toothbrushing effect with whitening toothpaste abrasion on root dentine

Vieira, Gustavo Henrique Apolinario January 2012 (has links)
VIEIRA, Gustavo Henrique Apolinário. Avaliação in vitro do efeito da escovação com dentifrícios clareadores sobre a superfície dentinária. 2012. 43 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia, e Enfermagem, Fortaleza, 2012. / Submitted by denise santos (denise.santos@ufc.br) on 2013-10-25T11:49:03Z No. of bitstreams: 1 2012_dis_ghavieira.pdf: 1153944 bytes, checksum: a5ce1178a6b7b8b1ae191774cca63540 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2013-10-25T11:50:10Z (GMT) No. of bitstreams: 1 2012_dis_ghavieira.pdf: 1153944 bytes, checksum: a5ce1178a6b7b8b1ae191774cca63540 (MD5) / Made available in DSpace on 2013-10-25T11:50:10Z (GMT). No. of bitstreams: 1 2012_dis_ghavieira.pdf: 1153944 bytes, checksum: a5ce1178a6b7b8b1ae191774cca63540 (MD5) Previous issue date: 2012 / Toothbrushing abrasion has an important role in the etiology of dentine hypersensitivity. The abrasion may be related to the abrasivity of the toothpaste. The aim of this study was to compare by mechanical profilometry the effect of toothbrushing abrasion with whitening and regular toothpastes on root dentine. Ninety dentine specimens (4x4x2 mm) were randomly divided into five experimental groups (n=18) according to the toothpaste: three whitening (W1, W2 and W3) and two regular toothpastes (C1 and C2), produced by two different manufacturers. Using a brushing machine, each specimen was brushed with constant load of 300g for 2500 cycles (4.5 cycles/second). The toothpastes were diluted at a ratio of 1:3 w/w (dentifrice/distilled water). The brush diamond tip of the profilometer moved at a constant speed of 0.05 mm/s with a force of 0.7 mN. The average reading value of brushing abrasion (μm; mean ± standard deviation) was obtained from five consecutive measurements of each specimen: W1 = 8.86 ± 1.58, W2 = 8.27 ± 2.39, W3 = 7.59 ± 1.04, R1 = 2.94 ± 1.29 and R2 = 2.89 ± 1.05. There was a significant difference between groups (ANOVA - p<0.0001). Post-hoc Tukey test for multiple comparison showed differences between all the whitening toothpastes and the regular ones, but not among the whitening or the regular against each other. Whitening toothpastes can cause more dentine abrasion than the regular ones. / A escovação tem um papel importante na etiologia da hipersensibilidade dentinária. Abrasão pode estar relacionada a abrasivos contidos nos dentifrícios. O objetivo deste estudo foi comparar por perfilometria mecânica o efeito da abrasão da escovação com dentifrícios clareadores e convencionais na dentina radicular. Noventa espécimes de dentina (4 x 4 x 2mm) foram aleatoriamente divididos em cinco grupos experimentais (n=18) de acordo com os dentifrícios: três clareadores (W1, W2, e W3) e dois convencionais (C1 e C2), produzidos por dois fabricantes distintos. Utilizando uma máquina de escovação, cada espécime foi escovado com carga constante de 300g por 2500 ciclos (4,5 ciclos por segundo). Os dentifrícios foram diluídos na proporção de 1:3 em peso (dentifrício/saliva artificial). A ponta diamantada do perfilômetro moveu-se em velocidade constante de 0,05mm/s com forca de 0,7mN. O valor médio das leituras da abrasão da escovação (μm; média ± desvio padrão) foi obtido de cinco leituras consecutivas em cada espécime: W1 = 8,86 ± 1,58, W2 = 8,27 ± 2,39, W3 = 7,59 ± 1,04, C1 = 2,94 ± 1,29 C2 = 2,89 ± 1,05. Houve diferença estatisticamente significante entre os grupos (ANOVA - p<0.0001). O teste de Tukey para múltiplas comparações mostrou diferenças entre todos os dentífricios clareadores e os convencionais, mas não entre os clareadores e os convencionais entre si. Dentifrícios clareadores podem causar mais abrasão na dentina do que os convencionais.
3

Citotoxicidade, produção de espécies reativas de oxigênio, expressão de marcadores celulares e produção de TNFα em macrófagos após exposição a agentes clareadores

Fernandes, Aletéia Massula de Melo [UNESP] 02 August 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-08-02Bitstream added on 2014-06-13T19:20:39Z : No. of bitstreams: 1 000757615.pdf: 3673125 bytes, checksum: f1ded8f52188174a05103c769c5b2cce (MD5) / O objetivo deste estudo foi avaliar a citotoxicidade, produção de espécies reativas de oxigênio, análise de marcadores celulares e presença de TNFα em macrófagos após exposição a agentes clareadores. Foram utilizadas culturas celulares de macrófagos RAW 264.7 expostas a dois géis clareadores: Peróxido de hidrogênio 40% e Peróxido de Carbamida 20% e ao Peróxido de Hidrogênio puro (10%) que atuou como controle positivo, em diversos períodos de avaliação. Esses clareadores foram utilizados sozinhos e aditivados à NAC e ao BSO. A viabilidade celular foi determinada pelo ensaio MTT, assim como a sobrevivência celular foi avaliada pelo ensaio cristal violeta. A liberação de espécies reativas de oxigênio foi mensurada utilizando uma sonda fluorescente sensível a oxidação-H2DCF-D. Para a verificação da presença dos marcadores celulares CD14, CD40 e CD54, envolvidos no processo inflamatório e na resposta imune, foi utilizada a citometria de fluxo, enquanto que a produção de TNFα foi quantificada por ELISA. A análise estatística foi realizada através do teste Mann–Whitney com nivel de significancia a 5%. Os resultados obtidos permitiram concluir que: todos os peróxidos diminuiram a viabilidade e a sobrevivência celular, sendo a toxicidade desses clareadores porporcional às suas concentrações; todos os peróxidos estimularam a produção de ROS, sendo que a NAC apresentou tendência a diminuir essa produção, enquanto que o BSO apresentou efeito oposto; a expressão dos marcadores celulares foram aumentadas pelo uso do LPS, sendo o marcador mais expresso o CD54, seguido pelo CD40 e CD14; a estimulação por LPS aumentou a produção de TNFα e os peróxidos tiveram a tendência a aumentar essa produção / The aim of this study was to evaluate the cytotoxicity, production of reactive oxygen species, analysis of cellular markers and the presence of TNFa in macrophages after exposure to bleaching agents. Cultures of RAW 264.7 macrophages were exposed to two bleaching gels: 40% Hydrogen Peroxide 20% Carbamide Peroxide; 10% pure Hydrogen Peroxide served as positive control, in different periods. These bleaching agents were used alone and associated with NAC and BSO. Cell viability was determined by MTT assay, and cell survival was assessed by crystal violet assay. The release of reactive oxygen species was measured using a fluorescent probe sensitive to oxidation-H2DCF-D. To verify the presence of the surface markers CD14, CD40, and CD54, involved in the inflammatory and immune response, it was used a flow cytometry, while the production of TNFa was measured by ELISA. Statistical analysis was performed using the Mann-Whitney test with a significance level of 5%. Results conclued that: all peroxides decreased the viability and cell survival, and toxicity of these bleaching was in proportion to their concentrations; all peroxides stimulated ROS production, and NAC showed a tendency to reduce this production while the BSO showed the opposite effect; the expression of surface markers were increased by the use of LPS, and the more expressed surface markers was the CD54, followed by CD40 and CD14; LPS stimulation increased the production of TNFα and peroxides had the tendency to increase this production, with the exception of higher concentrations, where most of the cells were dead
4

Ação de enxaguatórios clareadores e sua associação ao clareamento caseiro com peróxido de carbamida /

Oliveira, Juliana Boa Sorte de. January 2016 (has links)
Orientador: Caneppele, Taciana Marco Ferraz / Banca: Eduardo Bresciani / Banca: Carlos Martins Agra / Resumo: Objetivos: o objetivo deste estudo foi comparar a efetividade de enxaguatórios clareadores sobre dentes, clareados previamente ou não, expostos a corantes alimentícios. Material e Método: Cento e vinte espécimes de esmalte e dentina de 3 mm de diâmetro foram obtidos a partir de incisivos bovinos. Os espécimes foram manchados por 14 dias em caldo de manchamento. Após o manchamento, a leitura inicial da cor foi realizada, por meio do espectrofotômetro CM-2600d (Konica Minolta, Osaka, Japão). Sessenta espécimes (Subgrupos PC) foram submetidos ao clareamento com Peróxido de Carbamida a 10% por 14 dias. Após, foram subdividos em 4 subgrupos, com ciclos de manchamento (5 min) e enxaguatório (2 min) por 12 semanas, sendo PC-LI: Listerine Whitening Pré- escovação; PC-PL: Plax Whitening; PC-BP: Bromelina + Papaína; PC-AG: água deionizada. Os subgrupos LI, PL, BP e AG foram submetidos aos mesmos ciclos citados, porém não foram submetidos ao clareamento prévio. A leitura de cor dos espécimes foi feita após 4, 8 e 12 semanas de tratamento com os enxaguatórios. Os dados foram coletados e submetidos à Análise de variância (ANOVA) de medidas repetidas. A comparação entre os subgrupos para a avaliação das diferenças estatísticas foi realizada pelo Teste de Tukey. Todos os testes empregados admitiram 5% como nível de significância estatística. Os resultados mostraram que os valores de ΔL*, Δa*, Δb* e ΔE* confirmaram o clareamento para os subgrupos PC-LI, PC-PL, PC-BP e PC-AG, após o tratamento com peróxido de carbamida, e para os subgrupos PC-LI, PC-PL, LI e PL, após os ciclos manchamento-enxaguatório. Os subgrupos PC-BP e BP assemelharam-se aos subgrupos controle PC-AG e AG. Conclui-se, desse modo, que o enxaguatório bucal Listerine Whitening apresentou maior efeito clareador, seguido do enxaguatório Plax Whitening. Porém, nenhum desses enxaguatórios foi capaz de produzir clareamento semelhante ao evidenciado pelo.. / Abstract: Objectives: The aim of this study was to compare the effectiveness of whitening mouthrinses on teeth previously whitened or not, exposed to food dyes. Material and Methods: One hundred and twenty specimens of enamel and dentin of 3 mm in diameter were obtained from bovine incisors. The specimens were stained for 14 days in broth staining. After staining, the initial color reading was performed by a spectrophotometer CM-2600d (Konica Minolta, Osaka, Japan). Sixty specimens (Subgroups CP) were submitted to whitening (Carbamide Peroxide 10%) for 14 days. Then they were subdivided into 3 subgroups, and were submitted to cycles of staining (5 min) and mouthrinse (2 min) for 12 weeks, with CP-LI: Listerine Whitening Pré- Escovação; CP-PL: Plax Whitening; CP-BP: Bromelain + Papain; CP-DW: deionized water. LI, LP, BP and DW subgroups were submitted to the same cited cycles, but without bleaching before. The color measurements were performed after 4, 8 and 12 weeks of treatment with mouthrinses. Data were collected and subjected to analysis of variance (ANOVA) for repeated measures. The comparison between the subgroups for the evaluation of statistical differences was performed by Tukey test. All tests admitted statistical significance level of 5%. The results showed that the values ΔL*, Δa*, Δb* and ΔE* confirmed bleaching to PC-LI, PC-PL, PC-BP and PC-DW subgroups, after treatment with carbamide peroxide and to CP-LI, CP-PL, LI and PL subgroups, after the staining-mouthrinse cycles. CP-BP and BP subgroups were similar to CP-DW and DW. We conclude, therefore, that the mouthrinse Listerine Whitening presented the highest bleaching effect, followed by mouthrinse Plax Whitening. Both of them were able to maintain the bleaching effect of CP after 12 weeks of dye-rinse cycles. However, none of these rinses was able to produce whitening similar to that evidenced by the Carbamide Peroxide. The mouthrinse containing... / Mestre
5

Avaliação clínica dos efeitos da associação do peróxido de hidrogênio a 38% com o peróxido de carbamida a 10% /

Machado, Lucas Silveira. January 2013 (has links)
Orientador: Renato Herman Sundfeld / Banca: André Luiz Fraga Briso / Banca: Paulo Henrique dos Santos / Banca: Marcelo Giannini / Banca: Márcio Grama Hoeppner / Resumo: O objetivo deste estudo clínico foi avaliar os efeitos da associação de técnicas clareadoras com peróxido de hidrogênio (clareamento de consultório) e de carbamida (clareamento caseiro), na alteração de cor, sensibilidade dental, na morfologia e rugosidade superficial do esmalte dental. Fizeram parte dessa pesquisa clínica 21 voluntários, com faixa etária de 18-25 anos. Foram utilizados, de acordo com as especificações do fabricante, o produto clareador a base de peróxido de hidrogênio a 38% Opalescence Boost PF (Ultradent Products Inc., UT, EUA) e o a base de peróxido de carbamida a 10% Opalescence (Ultradent Products Inc., UT, EUA). O fator em estudo foi a "técnica clareadora" em 2 níveis: Técnica 1 (clareamento de consultório associado com clareamento caseiro) e Técnica 2 (apenas clareamento caseiro). Inicialmente, os voluntários tiveram suas hemi-arcadas superiores direita ou esquerda submetidas ao clareamento de consultório com 3 aplicações de 15 minutos cada de peróxido de hidrogênio a 38% ou placebo (Fase 1), respectivamente, caracterizando assim, um delineamento tipo split-mouth ou de boca dividida. Durante os 7 dias seguintes à Fase 1, os voluntários realizaram o clareamento caseiro utilizando o peróxido de carbamida a 10%, por 4 horas diárias (Fase 2) em ambos os lados; a Fase 1 e 2 foram repetidas por mais uma vez na semana seguinte. A mensuração da variável alteração de cor foi realizada nos incisivos e caninos superiores, pelo método visual (Vita Classical, Vita Zahnfabrik, Germany) e digital (Vita Easyshade, Vita Zahnfabrik, Germany), antes e após a Fase 1 e ao final do experimento; a variável sensibilidade foi analisada pelo método analógico visual; enquanto que as alterações da superfície de esmalte e... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this clinical study was to evaluate the association between two dental bleaching techniques - hydrogen peroxide bleaching (in-office bleaching) and carbamide peroxide (home bleaching) - and color change, dental sensitivity, morphology, and superficial roughness of dental enamel. Were performed two applications according to the manufacturer's specifications, one per week, of the in-office bleachingwith38% hydrogen peroxide. We applied the home bleaching technique for two weeks with 10% carbamide peroxide in a custom-made tray. The factor studied was the "bleaching technique" on 2 levels: Technique 1 (in-office bleaching associated with home bleaching) and Technique 2 (home bleaching only).The response variables were color change, dental sensitivity, morphology, and superficial roughness. According to a random draw, the volunteers had their maxillary right and left hemi arches submitted to in-office placebo treatment and to in-office bleaching, respectively (Phase 1), and at home bleaching (Phase 2) treatment for both hemi-arches, characterizing a split-mouth type of design. The color change was performed in the incisor and canine teeth by visual and digital evaluation before and after phase 1 and after the conclusion of each session of attendance. The dental sensitivity was assessed using the visual analogical method whereas the enamel surface changes and roughness were analyzed by electron microscopy (SEM) and by optical interferometry (IFM), through replicas clinically obtained based on central incisors before and after bleaching procedures. No differences were observed between the bleaching techniques for both the visual and digital analysis. There was a significant difference in the dental sensitivity... (Complete abstract click electronic access below) / Doutor
6

Avaliação in vitro da rugosidade e do desgaste dentinário após escovação com dentifrícios clareadores / In vitro evaluation of roughness and dentin wear after brushing with whitening toothpastes

Tahim, Catarina Martins January 2014 (has links)
TAHIM, Catarina Martins. Avaliação in vitro da rugosidade e do desgaste dentinário após escovação com dentifrícios clareadores. 2014. 45 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by denise santos (denise.santos@ufc.br) on 2015-05-20T12:31:12Z No. of bitstreams: 1 2014_dis_cmtahim.pdf: 1106236 bytes, checksum: 5f65ad6712fad90cdbf20ba395d4f426 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2015-05-20T12:37:54Z (GMT) No. of bitstreams: 1 2014_dis_cmtahim.pdf: 1106236 bytes, checksum: 5f65ad6712fad90cdbf20ba395d4f426 (MD5) / Made available in DSpace on 2015-05-20T12:37:55Z (GMT). No. of bitstreams: 1 2014_dis_cmtahim.pdf: 1106236 bytes, checksum: 5f65ad6712fad90cdbf20ba395d4f426 (MD5) Previous issue date: 2014 / The aim of this study was to compare the mechanical profilometry the abrasive effect of toothbrushing on root dentin with bleanching and conventional toothpastes. Ninety -six blocks of bovine root dentin (10x4x2 mm) were randomly divided into six experimental groups (n= 16) according to the dentifrices: four bleaching (W1, W2, W3 and W4) and two not bleaching (C1 and C2), produced by two different manufacturers. Using a brushing machine, each block was brushed with a constant load of 300 g for 2500 cycles (4.5 movements per second). The dentifrices were diluted in a 1:3 ratio by weight (Dentifrice/ remineralizing solution). The samples were evaluated by mechanical profilometry. The diamond tip of the profilometer moved at a constant speed of 0.05 mm/s with a force of 0.7 mN. The average readings of the wear and resulting surface roughness was obtained brushing five consecutive readings in each specimen. To wear in micrometers (μm): W1= 3,91±1,55; W2= 2,19±1,04; W3= 2,80±1,63; W4=1,41±0,69 ; C1= 1,42±0,71; C2= 0,86±0,33 and for roughness in micrometers (μm): W1= 0,70±0,46; W2= 0,32±0,21; W3= 0,49±0,26; W4= 0,23±0,11; C1= 0,20±0,08; C2= 0,13±0,04. There were significant differences between groups for both wear and surface roughness (ANOVA - P < 0.0001). Among the groups, it was observed that the W1 group showed higher roughness and wear, which was statistically different from all others. The W1 toothpaste along with toothpaste W3 showed differences from conventional toothpastes and W4. Among these differences were not observed. On the other hand, the whitening dentifrice W2 showed intermediate values being different from W1 and C2. A whitening toothpaste showed greater harmful potential with respect to wear and roughness of the others. Whitening dentifrices resulted in greater wear and a greater surface roughness than conventional dentifrices. / O objetivo do presente estudo foi comparar através de perfilometria mecânica o efeito abrasivo da escovação dental na dentina radicular com dentifrícios clareadores e convencionais. Noventa e seis blocos de dentina radicular bovina (10x4x2 mm) foram aleatoriamente distribuídos em seis grupos experimentais (n=16) de acordo com os dentifrícios: quatro clareadores (W1, W2, W3 e W4) e dois convencionais (C1 e C2), produzidos por dois fabricantes distintos. Utilizando uma máquina de escovação, cada bloco foi escovado com carga constante de 300g por 2500 ciclos (4,5 movimentos por segundo). Os dentifrícios foram diluídos na proporção de 1:3 em peso (dentifrício/solução remineralizante). As amostras foram avaliadas através de perfilometria mecânica. A ponta diamantada do perfilômetro se moveu a uma velocidade constante de 0,05 mm/s com uma força de 0,7mN. O valor médio das leituras do desgaste e rugosidade decorrentes da escovação foi obtido de cinco leituras consecutivas em cada espécime. Para Desgaste em micrômetros (μm): W1= 3,91±1,55; W2= 2,19±1,04; W3= 2,80±1,63; W4=1,41±0,69 ; C1= 1,42±0,71; C2= 0,86±0,33 e para rugosidade em micrômetros (μm): W1= 0,70±0,46; W2= 0,32±0,21; W3= 0,49±0,26; W4= 0,23±0,11; C1= 0,20±0,08; C2= 0,13±0,04. Houve diferenças significantes entre os grupos tanto para desgaste como para rugosidade (ANOVA - p<0.0001). Dentre os grupos, observou-se que o grupo W1 apresentou maior valor de rugosidade e desgaste, sendo estatisticamente diferentes de todos os demais. O dentifrício W1 juntamente com o dentifrício W3 apresentaram diferenças em relação ao dentifrício W4 e aos convencionais. Dentre estes não foram observadas diferenças. Por outro lado, o dentifrício clareador W2, apresentou valores intermediários sendo diferente de W1 e C2. Um dentifrício clareador apresentou maior potencial deletério em relação ao desgaste e à rugosidade dos que os demais. Dentifrícios clareadores resultaram em maior desgaste e em maior rugosidade de superfície do que os dentifrícios convencionais.
7

Avaliação clínica dos efeitos da associação do peróxido de hidrogênio a 38% com o peróxido de carbamida a 10%

Machado, Lucas Silveira [UNESP] 03 May 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-05-03Bitstream added on 2014-06-13T19:01:39Z : No. of bitstreams: 1 machado_ls_dr_araca.pdf: 4244386 bytes, checksum: 44f19a1237c274ea1f5b5a1532dd4547 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo clínico foi avaliar os efeitos da associação de técnicas clareadoras com peróxido de hidrogênio (clareamento de consultório) e de carbamida (clareamento caseiro), na alteração de cor, sensibilidade dental, na morfologia e rugosidade superficial do esmalte dental. Fizeram parte dessa pesquisa clínica 21 voluntários, com faixa etária de 18-25 anos. Foram utilizados, de acordo com as especificações do fabricante, o produto clareador a base de peróxido de hidrogênio a 38% Opalescence Boost PF (Ultradent Products Inc., UT, EUA) e o a base de peróxido de carbamida a 10% Opalescence (Ultradent Products Inc., UT, EUA). O fator em estudo foi a “técnica clareadora” em 2 níveis: Técnica 1 (clareamento de consultório associado com clareamento caseiro) e Técnica 2 (apenas clareamento caseiro). Inicialmente, os voluntários tiveram suas hemi-arcadas superiores direita ou esquerda submetidas ao clareamento de consultório com 3 aplicações de 15 minutos cada de peróxido de hidrogênio a 38% ou placebo (Fase 1), respectivamente, caracterizando assim, um delineamento tipo split-mouth ou de boca dividida. Durante os 7 dias seguintes à Fase 1, os voluntários realizaram o clareamento caseiro utilizando o peróxido de carbamida a 10%, por 4 horas diárias (Fase 2) em ambos os lados; a Fase 1 e 2 foram repetidas por mais uma vez na semana seguinte. A mensuração da variável alteração de cor foi realizada nos incisivos e caninos superiores, pelo método visual (Vita Classical, Vita Zahnfabrik, Germany) e digital (Vita Easyshade, Vita Zahnfabrik, Germany), antes e após a Fase 1 e ao final do experimento; a variável sensibilidade foi analisada pelo método analógico visual; enquanto que as alterações da superfície de esmalte e... / The objective of this clinical study was to evaluate the association between two dental bleaching techniques — hydrogen peroxide bleaching (in-office bleaching) and carbamide peroxide (home bleaching) – and color change, dental sensitivity, morphology, and superficial roughness of dental enamel. Were performed two applications according to the manufacturer's specifications, one per week, of the in-office bleachingwith38% hydrogen peroxide. We applied the home bleaching technique for two weeks with 10% carbamide peroxide in a custom-made tray. The factor studied was the bleaching technique on 2 levels: Technique 1 (in-office bleaching associated with home bleaching) and Technique 2 (home bleaching only).The response variables were color change, dental sensitivity, morphology, and superficial roughness. According to a random draw, the volunteers had their maxillary right and left hemi arches submitted to in-office placebo treatment and to in-office bleaching, respectively (Phase 1), and at home bleaching (Phase 2) treatment for both hemi-arches, characterizing a split-mouth type of design. The color change was performed in the incisor and canine teeth by visual and digital evaluation before and after phase 1 and after the conclusion of each session of attendance. The dental sensitivity was assessed using the visual analogical method whereas the enamel surface changes and roughness were analyzed by electron microscopy (SEM) and by optical interferometry (IFM), through replicas clinically obtained based on central incisors before and after bleaching procedures. No differences were observed between the bleaching techniques for both the visual and digital analysis. There was a significant difference in the dental sensitivity... (Complete abstract click electronic access below)
8

Efeito da escovação utilizando dentifrícios com diferentes graus de abrasividade no desgaste do esmalte após o uso de agentes clareadores com e sem cálcio, em diferentes intervalos de tempo

Santos, Luciana Floriani Thives Freitas [UNESP] 16 December 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:33:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-16. Added 1 bitstream(s) on 2015-06-18T12:48:09Z : No. of bitstreams: 1 000828037.pdf: 381697 bytes, checksum: eac0b0271a911a66df24071eb1f73ae3 (MD5) / O objetivo deste estudo foi avaliar os efeitos da escovação, utilizando dentifrícios com diferentes graus de abrasividade após a exposição ao agente clareador peróxido de hidrogênio (PH) 7,5% com ou sem a adição de gluconato de cálcio em diferentes intervalos de tempo (imediatamente e após 1 h). Foi analisada a alteração no tecido dental decorrente destas interações no desgaste de superfície do esmalte. Neste estudo foram utilizados 144 espécimes de esmalte bovino, os quais foram distribuídos em 12 grupos (n = 12) de acordo com o gel clareador utilizado (com e sem cálcio), o grau de abrasividade (alto ou baixo) e o intervalo de tempo decorrido após a utilização do gel clareador (imediatamente e após 1 h). Para o controle, 4 grupos não foram expostos ao gel clareador, apenas passaram pelos ciclos de abrasão, de acordo com o tipo de abrasivo e o intervalo de tempo. O gel clareador foi aplicado por 1 h e após este período, os grupos que foram escovados imediatamente, passaram para o ciclo de abrasão e os do intervalo de 1 h permaneceram na saliva artificial antes da realização dos ciclos abrasivos. Os espécimes foram submetidos a 45 ciclos de escovação, correspondentes a 3x ao dia (135 ciclos por dia - 1 min e 30 s). Estes procedimentos foram repetidos por 7 dias, totalizando 945 ciclos ao final do estudo. O desgaste da superfície do esmalte foi medido (μm) por perfilometria. Para verificação dos resultados foi aplicado o teste ANOVA três fatores e o teste de Tukey. O nível de significância foi de 5%. Foram observadas diferenças estatisticamente significantes (p=0,0001) para os três fatores testados. Os valores de média (± DP) e os resultados do teste de Tukey para o fator clareamento foram: SC- 0,45(± 0,01)a, PH+Ca- 0,51(± 0,03)b, PH- 0,82(± 0,01)c. Para o fator abrasivo, foram: Baixo- 0,44(± 0,01)a e Alto- 0,74(± 0,05)b e para o intervalo de tem... / The objective of this study was to evaluate the effects of brushing, using toothpastes with different degrees of abrasiveness after exposure to bleaching agent hydrogen peroxide (HP) 7.5% with or without the addition of calcium gluconate in different time intervals (immediately and after 1 h). The alteration in dental tissue resulting from these interactions on enamel surface wear was analyzed. In this study 144 bovine enamel specimens were divided into 12 groups (n = 12) according to the whitening gel used (with and without calcium), the grade of abrasive (high or low) and the time interval elapsed after use of the bleaching gel (immediately and after 1h). For the control, four groups were not exposed to the bleaching gel and were just submitted to abrasion cycles according to the type of abrasive and the time interval. The bleaching gel was applied for 1 h and after this period, the groups that were brushed immediately were submitted to abrasion cycle, and the ones tested after 1h, remained in artificial saliva before the performance of abrasive cycles. The specimens were subjected to 45 cycles of brushing, corresponding to 3x a day (135 cycles per day - 1 min 30 s). These procedures were repeated for 7 days, totaling 945 cycles at the end of the study. The enamel wear was measured (μm) by profilometry. To check the results, three-way ANOVA and Tukey's test was applied. The significance level was 5%. Statistically significant differences (p =0.0001) for the three tested factors were observed. Mean values (± SD) and results of Tukey test for whitening factor were: NB- 0.45(± 0.01)a, HP+Ca- 0.51(± 0.03)b, HP - 0.82(± 0.01)c. For the abrasive factor were: Low- 0.44(± 0.01)a and High- 0.74(± 0.05)b and for the time interval, were: 1h- 0.41(± 0.01)a, immediately- 0.77(± 0.05) b. It can be concluded that: a) HP 7.5% bleaching increased the enamel susceptibility to abrasion, b) the...
9

Influência da concentração de peróxido de hidrogênio nos agentes clareadores na cor e penetração através da estrutura dental

Godoy, Monique Martins Maia [UNESP] 04 August 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-08-04. Added 1 bitstream(s) on 2015-06-18T12:46:57Z : No. of bitstreams: 1 000828156.pdf: 392333 bytes, checksum: b79ac68a7ba3e049bf4d2f1d3915fbc4 (MD5) / O objetivo deste estudo foi avaliar os efeitos da concentração dos agentes clareadores na cor e penetração do peróxido de hidrogênio através da estrutura dental. Para tal foram preparadas 100 amostras cilíndricas de esmalte/dentina, com 6 mm de diâmetro e 2 mm de espessura (n = 20), obtidas a partir de dentes incisivos bovinos. Os espécimes foram divididos em cinco grupos, de acordo com a concentração de peróxido de hidrogênio contida nos géis clareadores empregados: 20%; 25%; 30%; 35% e 40%. Os espécimes foram posicionados sobre câmaras pulpares artificiais previamente preenchidas com uma solução tampão de acetato, e o clareamento foi realizado durante 30 minutos. Uma amostra de solução foi recolhida do interior da câmara pulpar artificial e a concentração de peróxido de hidrogênio mensurada em espectrofotômetro de absorbânica. Para a análise do efeito clareador, as coordenadas cromáticas L*a*b* foram mensuradas antes do procedimento e uma semana após o clareamento. Os dados foram analisados por meio de análise de variância (ANOVA) e teste de Tukey, ao nível de significância de 5%. A ANOVA mostrou diferenças significativas para penetração e cor (p<0,05). Os valores de média (±dp) e os resultados do teste de Tukey para penetração foram para cada concentração 20%:4,32 (±1,93) a, 25%: 4,33(±1,75) b, 30%: 6,42 (±2,64) c, 35%: 8,44 (± 3,03) d; 40%: 8,64 (±3,09) e. Com relação à cor, os resultados foram para ΔL: 20%: 2,47 (± 1,32) a, 25%: 2,55 (± 0,64)b, 30%: 2,78 (± 0,90)c, 35%: 3,30 (± 0,96)d, e 40%: 3,33 (± 1,56)e. Para Δa: 20%: -0,60 (± 0,66) a, 25%: -0,71 (± 0,37) b, 30%: -0,87 (±0,42) c, 35% -0,96 (± 0,55) d, e 40%: -1.09 (± 0,61) e. Para Δb: 20% -3,18 (± 1,57) a, 25%: - 3,44 (± 1,17) b, 30%: -3,77 (± 1,39) c, 35%: -5,28 (± 1,42) d e 40%: -5,35 (± 1,38) e. Para ΔE: 20%: -3,18 (± 1,57) a, 25%: -3,44 (± 1,17) b, 30%: -3,77... / The aim of this study was to evaluate the effects of bleaching agents on colour and the penetration of the hydrogen peroxide throughout the dental structure. One hundred cylindrical samples of enamel/dentin, obtained from bovine incisors, were prepared with 6mm of diameter and 2mm of thickness (n=20). The samples were divided into five groups, according to the concentration of hydrogen peroxide contained in bleaching gels eemployed: 20%; 25%; 30%; 35%; 40%. The samples were positioned over the artificial pulpar chambers containing an acetate buffer solution and the bleaching was performed for 30 minutes. A sample of the solution was collected and the concentration of the peroxide was measured by a spectrophotometer. To analyse the bleaching effectiveness, the chromatic coordinates Lab were measured, beforehand and one week later the bleaching procedure. The data were analysed by using the analysis of variance (ANOVA) and Tukey's test at a significance level of 5% (0.05). The mean value (+-dp) and the results of Tukey's test to hydrogen peroxide penetration were: 20%: 4.32 (±1.93) a, 25%: 4.33(±1.75) b, 30%: 6.42 (±2.64) c, 35%: 8.44 (± 3.03) d, 40%: 8.64 (±3.09) e. The results for color change were for ΔL: 20%: 2.47 (± 1.32) a, 25%: 2.55 (± 0.64)b, 30%: 2.78 (± 0.90)c, 35%: 3.30 (± 0.96)d, e 40%: 3.33 (± 1.56)e. for Δa: 20%: -0.60 (± 0.66) a, 25%: -0.71 (± 0.37) b, 30%: -0.87 (±0.42) c, 35% -0.96 (± 0.55) d, 40%: -1.09 (± 0.61) e. For Δb: 20% -3.18 (± 1.57) a, 25%: - 3.44 (± 1.17) b, 30%: -3.77 (± 1.39) c, 35%: -5.28 (± 1.42) d and 40%: -5.35 (± 1.38) e. For ΔE: 20%: -3.18 (± 1.57) a, 25%: -3.44 (± 1.17) b, 30%: -3.77 (± 1.39) c, 35%: - 5.28 (± 1.42) d, and 40% -5.35 (± 1.38) e. The groups followed by the same letter do not present significant differences. It was concluded that the increasing of peroxide concentration enhanced bleaching effect, but also increased the penetration through the tooh structure
10

Efetividade e sensibilidade com uso de géis clareadores experimental e comercial à base de peróxido de carbamida

Santana, Rosemary Soares de [UNESP] 24 November 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-11-24. Added 1 bitstream(s) on 2015-09-17T15:47:37Z : No. of bitstreams: 1 000843725.pdf: 2672521 bytes, checksum: ef18b307626f61cbba5deea1437f2396 (MD5) / Este estudo clínico avaliou a sensibilidade dentária (SD) e a efetividade do clareamento caseiro, bem como a reincidência de cor após uso de géis, à base de peróxido de carbamida (CP) comerciais contendo nitrato de potássio e fluoreto (PF) e experimentais (EX) contendo também tripolifosfato de sódio (STP). Cem pacientes foram submetidos ao tratamento de clareamento dental, sendo divididos aleatoriamente em 5 grupos (n = 20 / grupo): 1) Peróxido de carbamida PF Mint gel experimental 10% (EX10); 2) Peróxido de carbamida PF Mint gel experimental 20% (EX20); 3) Peróxido de carbamida comercial 10% (Opalescence PF 10% Mint) (OP10); 4) Peróxido de carbamida comercial 20% (Opalescence PF 20% Mint) (OP20); 5) Gel placebo de peróxido de carbamida (PL). Realizou-se clareamento em uma única arcada de cada paciente, por 2 horas/dia, durante 14 dias. Para análise da cor utilizou-se análise por espectrofotômetro, análise fotográfica e pela escala Vita Bleachedguide 3D Master nos períodos: inicial, 7 e 14 dias após o início do tratamento e 30 dias após o término para verificar a estabilidade da cor. A SD foi avaliada diariamente qualificando a intensidade da dor em: ausência, discreta, moderada, considerável e severa. Os resultados foram analisados pelos testes ANOVA (medidas repetidas) para mensuração por espectrofotômetro, teste Kruskal-Wallis para sensibilidade e Dunn para escala visual, significância 5%. A análise de cor visual apresentou p < 0.05, e a sensibilidade 0.0482 < 0.05. O gel de clareamento OP10 promoveu melhores resultados de cor e menor sensibilidade comparado ao EX10. O grupo EX20 apresentou maior ação clareadora com mesmo nível de sensibilidade que o grupo OP20. Concluiu-se que os grupos OP10 e EX20 promoveram os melhores resultados quanto ao clareamento com menor índice de sensibilidade quando comparados com os grupos de mesmas concentrações e que o STP influenciou na efetividade do clareamento / This clinical study assessed tooth sensitivity (SD) and the effectiveness of home bleaching as well as the color relapse after the use of based on commercial carbamide peroxide gels (CP) containing potassium nitrate and fluoride (PF) and experimental gels (EX) also containing sodium tripolyphosphate (STP). A hundred patients, who underwent tooth whitening treatment, were divided randomly into 5 groups (n = 20/groups): 1) 10% carbamide peroxide experimental gel PF Mint (EX10); 2) 20% carbamide peroxide experimental gel PF Mint (EX20); 3) 10% commercial carbamide peroxide gel (Opalescence 10% Mint PF) (OP10); 4) 20% commercial carbamide peroxide (Opalescence 20% Mint PF) (OP20); 5) placebo 0% carbamide peroxide gel PF mint (PL). Bleaching was performed on a single arch of each patient for 2 hours during 14 days. In order to evaluate the color, it was used spectrophotometer, photographic analysis, and Vita 3D Master Bleachedguide in the periods: initial, 7 and 14 days after the start of the treatment and 30 days after the end to verify the color stability. The SD was daily evaluated, according in the following grades: absence, mild, moderate, substantial and severe. The results were analyzed by ANOVA (repeated measures) for measurement by spectrophotometer, Kruskal-Wallis and Dunn tests, 5% of significance to sensitivity to visual scale. Comparisons of shade guide the color analysis showed p < 0.05, and sensitivity to 0.0482 < 0.05. The whitening gel OP10 promoted better color results and minor sensitivity compared to the EX10. And the EX20 group showed greater lightening action with same level of sensitivity as the OP20 group. It was concluded that the groups OP10 and EX20 promoted the best results regarding the whitening with the smallest rate of sensibility when compared to the groups with the same concentrations and there was STP influence on the whithening effectiveness

Page generated in 0.4862 seconds