Spelling suggestions: "subject:"column"" "subject:"kolumn""
121 |
海洋環境における鋼管杭の圧縮強度の経年変化予測法NAKAMURA, Hideharu, NAGATA, Kazutoshi, NOGAMI, Ikuei, SUGIURA, Kunitomo, ITOH, Yoshito, WATANABE, Eiichi, HASHIMOTO, Kazuaki, FUJII, Katashi, 中村, 秀治, 永田, 和寿, 野上, 邦栄, 杉浦, 邦征, 伊藤, 義人, 渡邊, 英一, 橋本, 和朗, 藤井, 堅 19 March 2010 (has links)
No description available.
|
122 |
Behaviour of Steel Plate Shear Walls Fabricated with Partially Encased Composite ColumnsDeng, Xiaoyan Unknown Date
No description available.
|
123 |
Seismic Behaviour of Exterior Beam-Column Joints Reinforced with FRP Bars and StirrupsMady, Mohamed Hassan Abdelhamed 25 August 2011 (has links)
Reinforced concrete beam-column joints (BCJs) are commonly used in structures such as parking garages, multi-storey industrial buildings and road overpasses, which might be exposed to extreme weathering conditions and the application of de-icing salts. The use of the non-corrodible fiber-reinforced polymer (FRP) reinforcing bars in such structures is beneficial to overcome the steel-corrosion problems. However, FRP materials exhibit linear-elastic stress-strain characteristics up to failure, which raises concerns on their performance in BCJs where energy dissipation, through plastic behaviour, is required. The objective of this research project is to assess the seismic behaviour of concrete BCJs reinforced with FRP bars and stirrups.
An experimental program was conducted at the University of Manitoba to participate in achieving this objective. Eight full-scale exterior T-shaped BCJs prototypes were constructed and tested under simulated seismic load conditions. The longitudinal and transversal reinforcement types and ratios for the beam and the columns were the main investigated parameters. The experimental results showed that the GFRP reinforced joints can successfully sustain a 4.0% drift ratio without any significant residual deformation. This indicates the feasibility of using GFRP bars and stirrups as reinforcement in the BCJs subjected to seismic-type loading. It was also concluded that, increasing the beam reinforcement ratio, while satisfying the strong column-weak beam concept, can enhance the ability of the joint to dissipate seismic energy.
An analytical investigation was conducted through constructing a finite element model using ANSYS-software. The model was verified against the experimental results in this research. Then, a parametric study was performed on number of different parameters known to affect such joints including column axial load, concrete compressive strength, flexural strength ratio and joint transverse reinforcement. It was concluded that 70% of the column axial load capacity can be recommended as an upper limit to the applied axial loads on the column to avoid damage occurrence within the joint. It was also concluded that a minimum flexural strength ratio of 1.50 is recommended to ensure the strong-column weak-beam mechanism. In addition, a minimum joint transverse reinforcement ratio of 0.60% is recommended to insure that the failure will not occur in the joint zone.
|
124 |
Investigation into phosphorus removal by iron ochre for the potential treatment of aquatic phosphorus pollutionCarr, Stephen Thomas David January 2012 (has links)
Phosphorus (P) pollution of waterbodies is a global issue with detrimental environmental, social and economic impacts. Low-cost and sustainable P removal technologies are therefore required to tackle P pollution, whilst also offering a technique for reclaiming P. Ochre, a waste product from minewater treatment plants (MWTPs), has been proposed as a suitable material for the removal of P from enriched waters due to a high content of Fe, Al, Ca and Mg, which have high affinities for P removal. Whilst a range of studies have been conducted investigating ochre as a P adsorbent, most of these are large-scale field experiments and lack understanding of the underlying processes of P removal by ochre. There have also been very few detailed comparisons of different ochre types. The primary focus of this thesis is thus to provide a process-based understanding of P removal by various ochres, in order to investigate the optimal conditions for the use of ochres in the treatment of aquatic P pollution. Seven ochres from six MWTPs in the UK and Ireland were investigated, one of which was in a pelleted form. The ochres were largely comprised of Al, Ca, Fe and Mg (42-68 % by dry weight), had a high B.E.T. surface area, 56-243 m2 g-1, and contained mineral surfaces with a high affinity for P adsorption, such as goethite and calcite. A novel batch experiment methodology was utilised to calculate the adsorption characteristics of ochre at discrete pH conditions. The variation of these characteristics with pH indicates the importance and requirement for such a method to study adsorption by materials at the expected pH conditions of application. At the pH conditions of wastewater streams (~pH 7), the P adsorption capacities of the ochres, determined from fitting adsorption isotherms, was 11.8–43.1 mg P g-1. Results of P adsorption batch experiments were modelled in ORCHESTRA, wherein P removal by the ochres was described well by adsorption onto hydrous ferric oxides. Three of the ochres contain relatively high calcite contents and due to a poor fit of the model to the observed datasets at high pH conditions, with equilibrium P concentrations lower in the batch experiments than the modelled result, adsorption onto calcite is suggested as a P removal mechanism for these ochres at pH > 7. Environmental application of ochre filters will require P removal under flow-through transport conditions. Column experiments were therefore conducted using two ochres, coarse-grained Polkemmet ochre and Acomb pellets (column volume 1055 cm3, pore space 490-661 cm3, typical pore volumes of experiments: 220-400). P removal efficiency increased with contact time, and the presence of competing ions had only marginal effects on P removal. Resting the column substrate for 48 hours between P applications greatly increased the P removal efficiency of a packed column of Polkemmet ochre, resulting in 81 % of influent P removed over 1000 pore volumes of operation (7.68 mg P g-1). Acomb pellets had a lower P removal efficiency than Polkemmet ochre. It is suggested that the high calcium content of the pellets, as a result of the pelletisation process, has created a substrate where the dominant P removal mechanism at neutral pH conditions is adsorption to calcite, which has slower reaction kinetics than adsorption onto goethite. Therefore, this pelleted ochre requires a higher contact time for adsorption reactions to occur. It is suggested that ochre filters are most suitable for application in situations where flow rate is constant or can be controlled e.g. septic tank effluent. Ochres which dry to a coarse particle size are preferred for use as a substrate as pelletisation requires capital, expertise and can produce substrates with slower P sorption kinetics. Resting the filter substrate between P application regenerates surface sites for adsorption, and filters should be run in parallel to maximise P removal efficiency. Acomb pellets, which are a mix of iron hydroxides and alkaline materials, may have potential application as a permeable reactive barrier substrate to treat P enriched ground waters. Further research utilising fine-grained ochres as an additive to P rich fertilisers or for use in continuously stirred tank reactors is recommended.
|
125 |
Further experiments on the seismic performance of structural concrete beam-column joints designed in accordance with the principles of damage avoidanceLi, Luo man January 2006 (has links)
Recent research on jointed unbonded post-tensioned precast concrete frames has demonstrated their superior seismic resistance. Inelastic rotation generated during large earthquake motions is accommodated through gap opening and closing at the beam-to-column connections in the frame. By applying the principles of Damage Avoidance Design (DAD), a steel-steel armoured connection has been demonstrated to be effective in protecting the precast elements from damage. The re-centring ability of the unbonded prestressed post-tensioned system allows the building to return to its original undeformed position after the earthquake with negligible residual deformations. This research experimentally assesses the biaxial performance of the unbonded precast beam-to-column joint and simplifies the steel-steel armoured connection details in the joint. The experimental results of both quasi-static unidirectional lateral loading tests and biaxial lateral loading tests conducted on a 80% scaled unbonded jointed beam-to-column joint are presented. The performance of the proposed simplified steel-steel connection is assessed. A theoretical model is developed based primarily on rigid body kinematics and is validated using the test results. A formulation is also developed based on St Vennants' principle, to estimate the effective stiffness of the precast concrete beams under bidirectional rocking. Based on the experimental findings, improvements to the steel-steel armoured connection and joint details are proposed.
|
126 |
Seismic Assessment of Pre-1970s Reinforced Concrete StructureHertanto, Eric January 2005 (has links)
Reinforced concrete structures designed in pre-1970s are vulnerable under earthquakes due to lack of seismic detailing to provide adequate ductility. Typical deficiencies of pre-1970s reinforced concrete structures are (a) use of plain bars as longitudinal reinforcement, (b) inadequate anchorage of beam longitudinal reinforcement in the column (particularly exterior column), (c) lack of joint transverse reinforcement if any, (d) lapped splices located just above joint, and (e) low concrete strength. Furthermore, the use of infill walls is a controversial issue because it can help to provide additional stiffness to the structure on the positive side and on the negative side it can increase the possibility of soft-storey mechanisms if it is distributed irregularly. Experimental research to investigate the possible seismic behaviour of pre-1970s reinforced concrete structures have been carried out in the past. However, there is still an absence of experimental tests on the 3-D response of existing beam-column joints under bi-directional cyclic loading, such as corner joints. As part of the research work herein presented, a series of experimental tests on beam-column subassemblies with typical detailing of pre-1970s buildings has been carried out to investigate the behaviour of existing reinforced concrete structures. Six two-third scale plane frame exterior beam-column joint subassemblies were constructed and tested under quasi-static cyclic loading in the Structural Laboratory of the University of Canterbury. The reinforcement detailing and beam dimension were varied to investigate their effect on the seismic behaviour. Four specimens were conventional deep beam-column joint, with two of them using deformed longitudinal bars and beam bars bent in to the joint and the two others using plain round longitudinal bars and beam bars with end hooks. The other two specimens were shallow beam-column joint, one with deformed longitudinal bars and beam bars bent in to the joint, the other with plain round longitudinal bars and beam bars with end hooks. All units had one transverse reinforcement in the joint. The results of the experimental tests indicated that conventional exterior beam-column joint with typical detailing of pre-1970s building would experience serious diagonal tension cracking in the joint panel under earthquake. The use of plain round bars with end hooks for beam longitudinal reinforcement results in more severe damage in the joint core when compared to the use of deformed bars for beam longitudinal reinforcement bent in to the joint, due to the combination of bar slips and concrete crushing. One interesting outcome is that the use of shallow beam in the exterior beam-column joint could avoid the joint cracking due to the beam size although the strength provided lower when compared with the use of deep beam with equal moment capacity. Therefore, taking into account the low strength and stiffness, shallow beam can be reintroduced as an alternative solution in design process. In addition, the presence of single transverse reinforcement in the joint core can provide additional confinement after the first crack occurred, thus delaying the strength degradation of the structure. Three two-third scale space frame corner beam-column joint subassemblies were also constructed to investigate the biaxial loading effect. Two specimens were deep-deep beam-corner column joint specimens and the other one was deep-shallow beam-corner column joint specimen. One deep-deep beam-corner column joint specimen was not using any transverse reinforcement in the joint core while the two other specimens were using one transverse reinforcement in the joint core. Plain round longitudinal bars were used for all units with hook anchorage for the beam bars. Results from the tests confirmed the evidences from earthquake damage observations with the exterior 3-D (corner) beam-column joint subjected to biaxial loading would have less strength and suffer higher damage in the joint area under earthquake. Furthermore, the joint shear relation in the two directions is calibrated from the results to provide better analysis. An analytical model was used to simulate the seismic behaviour of the joints with the help of Ruaumoko software. Alternative strength degradation curves corresponding to different reinforcement detailing of beam-column joint unit were proposed based on the test results.
|
127 |
Retrofit strategy of non-seismically designed frame systems based on a metallic haunch systemChen, Te-Hsiu January 2006 (has links)
Due to the lack of capacity design principles as well as of appropriate structural details, most of the reinforced concrete building designed primarily for gravity loads as typical of pre- 1970s code provisions, are expected and has been demonstrate to suffer sever damage or total collapse under the earthquake excitation. Due to the use of plain round bar and inadequate reinforcing details, critical shear failure in the joint connection region could occur, leading to sever damage when not total collapse of the building. In this research project, a comprehensive experimental programme was carried to investigate the seismic performance of existing beam column joints prior and after retrofit intervention with a recently proposed low-invasive retrofit technique based on a metallic haunch system. The joint performance was evaluated in terms of the principal tensile stresses that caused the joint shear cracks in the joint panel zone. Quasi-static cyclic tests under uni-directional or bidirection loading regime were carried out to record the response of a series of under-designed beam column joints (with either a wide-beam or a deep-beam solution, deformed or plain round bars with end hooks). The experimental results were used to investigate the effect of structural detailing and loading regime on the seismic performance. To retrofit the potential deficiencies in the existing beam-column joints, the feasibility and efficiency of a low invasive retrofit solution based on a diagonal metallic haunch was investigated. The proposed haunch retrofit solution aims to provides an economic, ease of implementation alternative to protect the joint from the brittle shear failure by relocating the beam plastic hinge away form the joint panel zone. To achieve the desired capacity design (hierarchy of strength) and sequence of event, a simplified analytical formulation has been adopted to account for the joint shear strength in terms of principle tensile/compression stresses prior and after the retrofit intervention. A useful visualization tool based on a M-N (moment-axial load) performance domain can be adopted to evaluate the actual performance point and events, by comparing demand vs. capacity. Designed charts are proposed based on displacement compatibility conditions to evaluate the efficiency of the haunch solution. In addition, a complete step-by step design procedure to implement the retrofit strategy and intervention to achieve the desired hierarchy of strength, by using the proposed diagonal metallic haunch solution, is derived and presented. The effectiveness of the proposed haunch solution and reliability of the derived analytical design/assessment procedure, were validated through experimental tests of 2-D and 3-D subassemblies, shown in the first experimental part to have the most vulnerable behaviour in the joint panel zone. Conceptual issues related to the design of the retrofit intervention, when moving from a 2-D to a 3-D behaviour are discussed. The experimental results showed an excellent performance of the proposed intervention, able to protect the panel zone region (by limiting the principle tensile stress demand), while enforcing the formation of a plastic hinge in the beam, far away from the joint interface. As a result, a much more stable inelastic response could be developed, confirming the high potential of such a low-invasive, low-cost retrofit intervention on under-designed frame systems. In conclusion, a simple numerical model, based on a lumped plasticity approach, was developed and validated on the experimental results to capture the full response of the subassembly prior and after the retrofit intervention.
|
128 |
GFRP-reinforced concrete exterior beam-column joints subjected to seismic loadingHasaballa, Mohamed 29 October 2014 (has links)
Glass fibre-reinforced polymer (GFRP) reinforcement is used in reinforced concrete (RC) infrastructure to avoid steel corrosion problems. The behaviour of GFRP reinforcement under seismic loading in RC frame structures has not been widely investigated. The behaviour of beam-column joints significantly influences the response of the Seismic Force Resisting Systems. Therefore, both the design and detailing of the beam-column joints are critical to secure a satisfactory seismic performance of these structures. However, the current Canadian FRP design codes (CSA 2012, CSA 2006) have no considerable seismic provisions, if any, due to lack of data and research in this area. Such lack of information does not allow for adequate designs and subsequently limits the implementation of FRP reinforcement as a non-corrodible and sustainable reinforcement in new construction. Therefore, it deemed necessary to track areas of ambiguity and lack of knowledge to provide design provisions and detailing guidelines.
This study investigated the seismic behaviour of the GFRP-RC exterior beam-column joints. The study consisted of an experimental phase, in which ten full-scale T-shaped GFRP-RC specimens were constructed and tested to failure, and an analytical phase using finite element modelling (FEM). Specimens in the experimental phase were designed to investigate the anchorage detailing of beam longitudinal reinforcement inside the joint (using either bent bars or headed bars) and to evaluate the shear capacity of the joint.
In the analytical phase, a commercial FEM software (ATENA-3D) was used to run a parametric study that investigated the influence of the presence of lateral beams, axial load on the column, applied shear stresses in the joint, and the concrete strength.
Test results showed that the performance of the specimens reinforced with GFRP headed bars was comparable to their counterparts reinforced with bent bars up to 4.0% drift ratio. The difference in the reinforcement surface conditions had insignificant influence on the overall behaviour. Moreover, it was concluded that the shear capacity of GFRP-RC beam-column joints is 0.85 √f'c. Furthermore, an evaluation of the relevant seismic provisions in the CSA/S806-12 (CSA 2012) was carried out and some recommendations were proposed for consideration in the future updates of the CSA/S806-12.
|
129 |
Strengthening Slender S-Section Steel Columns Using CFRP Plates of Various ModuliRitchie, ALLISON 02 July 2014 (has links)
This thesis investigates strengthening slender steel columns with carbon fibre reinforced polymer (CFRP) plates of various moduli. Three different types of CFRP were used in the study: Ultra-high modulus (430GPa), High modulus (212GPa) and Normal modulus (168GPa). In this study, specimens were grouped according to measured initial out-of-straightness values. The first section examines the effect of adding CFRP plates to the column flanges when buckling about the weak axis. Twelve columns, with a slenderness ratio of 197, were tested, of which nine were strengthened with CFRP. The main parameters tested were the level of initial out-of-straightness (length (L)/8387 to L/1020), CFRP modulus (168 to 430 GPa), CFRP reinforcement ratio (13% to 34%) and the length of CFRP plate (33% to 95% of L). The gain in axial strength due to CFRP retrofitting ranged from 11% to 29%, depending on the various parameters. The gain generally increased as CFRP modulus, initial out-of-straightness, or CFRP reinforcement ratio increased. Global buckling consistently governed the maximum load. In the case of the 430 GPa CFRP, buckling was followed by CFRP crushing in compression, then rupture in tension.
The second section of the thesis examines the effect of CFRP plates added to the flanges and tested for buckling in the strong axis. Eight columns, with a slenderness ratio of 83, were tested of which five were strengthened with CFRP. The main parameters examined were the level of initial out-of-straightness (L/28889 to L/1635), CFRP modulus (168 to 430 GPa), CFRP reinforcement ratio (13% to 34%) and the axis of bending. The gain in axial strength due to CFRP retrofitting ranged from 0% to 25%, depending on the various parameters. The gain generally increased as initial out-of-straightness, or CFRP reinforcement ratio increased. The higher modulus did not perform as expected, showing no gain in strength, because the compressive strains were too large and the CFRP crushed before the specimen experienced any gain. Specimens compared with the weak axis, strengthened with normal modulus CFRP, had similar percentage gains in strength. / Thesis (Master, Civil Engineering) -- Queen's University, 2014-06-27 15:19:03.397
|
130 |
Seismic Behaviour of Exterior Beam-Column Joints Reinforced with FRP Bars and StirrupsMady, Mohamed Hassan Abdelhamed 25 August 2011 (has links)
Reinforced concrete beam-column joints (BCJs) are commonly used in structures such as parking garages, multi-storey industrial buildings and road overpasses, which might be exposed to extreme weathering conditions and the application of de-icing salts. The use of the non-corrodible fiber-reinforced polymer (FRP) reinforcing bars in such structures is beneficial to overcome the steel-corrosion problems. However, FRP materials exhibit linear-elastic stress-strain characteristics up to failure, which raises concerns on their performance in BCJs where energy dissipation, through plastic behaviour, is required. The objective of this research project is to assess the seismic behaviour of concrete BCJs reinforced with FRP bars and stirrups.
An experimental program was conducted at the University of Manitoba to participate in achieving this objective. Eight full-scale exterior T-shaped BCJs prototypes were constructed and tested under simulated seismic load conditions. The longitudinal and transversal reinforcement types and ratios for the beam and the columns were the main investigated parameters. The experimental results showed that the GFRP reinforced joints can successfully sustain a 4.0% drift ratio without any significant residual deformation. This indicates the feasibility of using GFRP bars and stirrups as reinforcement in the BCJs subjected to seismic-type loading. It was also concluded that, increasing the beam reinforcement ratio, while satisfying the strong column-weak beam concept, can enhance the ability of the joint to dissipate seismic energy.
An analytical investigation was conducted through constructing a finite element model using ANSYS-software. The model was verified against the experimental results in this research. Then, a parametric study was performed on number of different parameters known to affect such joints including column axial load, concrete compressive strength, flexural strength ratio and joint transverse reinforcement. It was concluded that 70% of the column axial load capacity can be recommended as an upper limit to the applied axial loads on the column to avoid damage occurrence within the joint. It was also concluded that a minimum flexural strength ratio of 1.50 is recommended to ensure the strong-column weak-beam mechanism. In addition, a minimum joint transverse reinforcement ratio of 0.60% is recommended to insure that the failure will not occur in the joint zone.
|
Page generated in 0.0577 seconds