• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação de glifosato e ácido aminometilfosfônico em amostras ambientais por cromatografia a líquido em fase reversa controlada por injeção sequencial / Determination of glyphosate and aminomethylphosphonic acid in environmental samples by reversed-phase liquid chromatography controlled by sequential injection

Pereira, Erico Aparecido Oliveira 18 July 2018 (has links)
Introduzido na década de 1970, o glifosato figura entre os herbicidas mais consumidos em todo mundo. Devido a características como baixa toxicidade aguda a organismos não-alvo e alta eficiência na eliminação de plantas daninhas, o herbicida se tornou um sucesso de vendas, com um substancial incremento em sua utilização após o desenvolvimento de culturas geneticamente modificadas para tolerar o ingrediente ativo. O elevado consumo do glifosato vem se tornando uma preocupação para diferentes agências ambientais e de saúde. Consequentemente, métodos eficientes para a determinação e quantificação do herbicida se fazem necessários. Na presente dissertação, aprimorou-se um método que utiliza um sistema de análise de injeção sequencial por cromatografia líquida (SIC) com detecção por fluorescência para a determinação de glifosato e seu principal produto de degradação, o ácido aminometilfosfônico (AMPA), em amostras ambientais. Os limites de detecção (LD) e quantificação (LQ) para o glifosato foram 0,10 e 0,33 ԁmol L-1, respectivamente. Já para o AMPA, LD foi de 0,07 µmol L-1 e LQ de 0,22 µmol L-1. O método foi empregado na determinação das espécies em amostras de água fortificadas e gerou valores de recuperação entre 97,2 a 151,5% para o AMPA e 74,6 a 140,5% para o glifosato. Quando empregado em um estudo de adsorção-dessorção, o método foi capaz de produzir valores dos parâmetros de Freundlich e Langmuir comparáveis aos encontrados na literatura. Com qmax = 2,1 ± 0,1 µmol g-1 e KF = 0,53 ± 0,07 µmol1-1/n L1/n g-1, o Latossolo B se mostrou como o solo com maior capacidade de adsorver o glifosato. Em termos de dessorção, o percentual dessorvido ficou abaixo de 55% da quantidade inicialmente adsorvida para as concentrações trabalhadas. / Introduced in the 1970, glyphosate figures among the most used herbicides in the world. Due to characteristics such as low acute toxicity to non-target organisms and high efficiency regarding the elimination of weeds, the herbicide has experienced a huge success in terms of safes. Since genetically modified crops that tolerate the active ingredient have been developed, these safes have continued to increase. Glyphosate\'s high consumption has become a concern to different environmental and health agencies. As a result, efficient methods for the determination of glyphosate and its main metabolite, aminomethylphosphonic acid (AMPA), are necessary. This dissertation describes improvements in a sequential injection chromatography method for the determination of glyphosate and aminomethylphosphonic acid in environmental samples. The limits of detection (LOD) and quantification (LOQ) for glyphosate is 0.10 e 0.33 µmol L-1, respectively. LOD of 0.07 µmol L-1 and LOQ of 0,22 µmol L-1 is registered for AMPA. The method was employed for the determination of both species in spiked water samples and recovery values between 97.2 a 151.5% was obtained for AMPA and between 74.6 a 140.5% for glyphosate. When used in an adsorption-desorption study, the method was capable of generating values for the Freundlich and Langmuir parameters that are similar to those found in the scientific literature. With a qm\" of 2.1 ± 0.1 µmol g-1 and KF = 0.53 ± 0.07 µmol1-1/n L1/n g-1, Latossolo B was the soil sample with the largest glyphosate adsorption capacity. Regarding desorption, the percentages desorbed were beiow 55% of the initial mass of glyphosate adsorbed for the concentrations used.
2

Determinação de glifosato e ácido aminometilfosfônico em amostras ambientais por cromatografia a líquido em fase reversa controlada por injeção sequencial / Determination of glyphosate and aminomethylphosphonic acid in environmental samples by reversed-phase liquid chromatography controlled by sequential injection

Erico Aparecido Oliveira Pereira 18 July 2018 (has links)
Introduzido na década de 1970, o glifosato figura entre os herbicidas mais consumidos em todo mundo. Devido a características como baixa toxicidade aguda a organismos não-alvo e alta eficiência na eliminação de plantas daninhas, o herbicida se tornou um sucesso de vendas, com um substancial incremento em sua utilização após o desenvolvimento de culturas geneticamente modificadas para tolerar o ingrediente ativo. O elevado consumo do glifosato vem se tornando uma preocupação para diferentes agências ambientais e de saúde. Consequentemente, métodos eficientes para a determinação e quantificação do herbicida se fazem necessários. Na presente dissertação, aprimorou-se um método que utiliza um sistema de análise de injeção sequencial por cromatografia líquida (SIC) com detecção por fluorescência para a determinação de glifosato e seu principal produto de degradação, o ácido aminometilfosfônico (AMPA), em amostras ambientais. Os limites de detecção (LD) e quantificação (LQ) para o glifosato foram 0,10 e 0,33 ԁmol L-1, respectivamente. Já para o AMPA, LD foi de 0,07 µmol L-1 e LQ de 0,22 µmol L-1. O método foi empregado na determinação das espécies em amostras de água fortificadas e gerou valores de recuperação entre 97,2 a 151,5% para o AMPA e 74,6 a 140,5% para o glifosato. Quando empregado em um estudo de adsorção-dessorção, o método foi capaz de produzir valores dos parâmetros de Freundlich e Langmuir comparáveis aos encontrados na literatura. Com qmax = 2,1 ± 0,1 µmol g-1 e KF = 0,53 ± 0,07 µmol1-1/n L1/n g-1, o Latossolo B se mostrou como o solo com maior capacidade de adsorver o glifosato. Em termos de dessorção, o percentual dessorvido ficou abaixo de 55% da quantidade inicialmente adsorvida para as concentrações trabalhadas. / Introduced in the 1970, glyphosate figures among the most used herbicides in the world. Due to characteristics such as low acute toxicity to non-target organisms and high efficiency regarding the elimination of weeds, the herbicide has experienced a huge success in terms of safes. Since genetically modified crops that tolerate the active ingredient have been developed, these safes have continued to increase. Glyphosate\'s high consumption has become a concern to different environmental and health agencies. As a result, efficient methods for the determination of glyphosate and its main metabolite, aminomethylphosphonic acid (AMPA), are necessary. This dissertation describes improvements in a sequential injection chromatography method for the determination of glyphosate and aminomethylphosphonic acid in environmental samples. The limits of detection (LOD) and quantification (LOQ) for glyphosate is 0.10 e 0.33 µmol L-1, respectively. LOD of 0.07 µmol L-1 and LOQ of 0,22 µmol L-1 is registered for AMPA. The method was employed for the determination of both species in spiked water samples and recovery values between 97.2 a 151.5% was obtained for AMPA and between 74.6 a 140.5% for glyphosate. When used in an adsorption-desorption study, the method was capable of generating values for the Freundlich and Langmuir parameters that are similar to those found in the scientific literature. With a qm\" of 2.1 ± 0.1 µmol g-1 and KF = 0.53 ± 0.07 µmol1-1/n L1/n g-1, Latossolo B was the soil sample with the largest glyphosate adsorption capacity. Regarding desorption, the percentages desorbed were beiow 55% of the initial mass of glyphosate adsorbed for the concentrations used.
3

“Preparação de fases estacionárias monolíticas em capilares revestidos com poliacrilato para aplicação em eletrocromatografia capilar”

Vaz, Fernando Antonio Simas 03 April 2007 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-02-10T12:06:30Z No. of bitstreams: 1 fernandoantoniosimasvaz.pdf: 2762822 bytes, checksum: cc0ea5c3232ea493d5b831119c79a7f3 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-02-10T13:37:05Z (GMT) No. of bitstreams: 1 fernandoantoniosimasvaz.pdf: 2762822 bytes, checksum: cc0ea5c3232ea493d5b831119c79a7f3 (MD5) / Made available in DSpace on 2017-02-10T13:37:05Z (GMT). No. of bitstreams: 1 fernandoantoniosimasvaz.pdf: 2762822 bytes, checksum: cc0ea5c3232ea493d5b831119c79a7f3 (MD5) Previous issue date: 2007-04-03 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Nesta dissertação é descrita a polimerização fotoiniciada de fases estacionárias monolíticas (FEM) em capilares de sílica fundida revestidos com poliacrilato através do método sol-gel. O objetivo deste estudo foi contribuir para a implementação da Eletrocromatografia Capilar (ECC) na Universidade Federal de Juiz de Fora (UFJF). O Capítulo 1 descreve brevemente a CEC, relacionando-a com a Eletroforese Capilar (EC) e a Cromatografia Líquida de Alta Eficiência (CLAE). Características gerais das fases estacionárias, incluindo as colunas monolíticas, são discutidas. O Capítulo 2 apresenta os reagentes, soluções, ateriais, equipamentos e métodos envolvidos na preparação, avaliação e aplicação das colunas monolíticas. Uma breve discussão sobre o processo sol-gel é realizada. Alguns parâmetros relacionados ao preparo e timização das colunas monolíticas são discutidos no Capítulo 3. Em geral, as etapas de preparação de uma coluna são simples. O revestimento de poliacrilato, em contraste com o de poliimida, é transparente à radiação usada, tornando possível a polimerização fotoiniciada sem a retirada do revestimento. Além do mais, esta característica facilita a visualização durante o processo de preenchimento, bem como a observação da FEM obtida. O Capítulo 4 mostra os resultados obtidos para a avaliação da qualidade da FEM no que diz respeito à permeabilidade, resistência mecânica e propriedades eletrocromatográficas. A quantidade de solvente usada na preparação do sol está relacionada com a permeabilidade da FEM obtida. O comportamento eletrocromatográfico foi testado mediante a separação da mistura padrão contendo propilbenzeno, fenatreno e pireno em colunas de 125 µm de diâmetro interno. O Capítulo 5 descreve a construção de uma câmara de luz UV-Vis equipada com lâmpadas fluorescentes negras e brancas para aplicação na polimerização fotoiniciada. Algumas vantagens deste reator fotoquímico são: baixo custo (em torno de R$ 300,00), sendo que todas as peças podem ser adquiridas em comércio local; simples adaptações podem ser implementadas de acordo com a conveniência e propósitos do sistema; possui um apoio móvel, permitindo que a amostra possa ser posicionada em diferentes alturas da fonte de emissão. A construção da câmara mostrada neste trabalho é uma grande alternativa para grupos interessados neste tipo de instrumento que não possuam muitos recursos financeiros. No capítulo 6 são discutidos aspectos e conclusões obtidos na execução do projeto. O Apêndice A mostra alguns resultados experimentais obtidos na preparação de FEM por polimerização térmica. / This dissertation describes monolithic stationary phase (MSP) photo-initiated polymerization in polyacrylate-coated fused silica capillaries using a sol-gel approach. The objective of this study was to contribute for implementation of Capillary Electrochromatography (CEC) at Juiz de Fora Federal University (UFJF). Chapter 1 briefly describes CEC, relating it with Capillary Electrophoresis (CE) and High Performance Liquid Chromatography (HPLC). General features about stationary phases, including monolithic columns, are discussed. Chapter 2 presents reagents, solutions, materials, equipments and methods used for the preparation, evaluation and application of the monolithic columns, as well a brief discussion about the sol-gel approach. Some parameters related with preparation and optimization of the monolithic columns are discussed in Chapter 3. In general, MSP preparation steps are simple. The polyacrylate coating, unlike the polyimide one, is transparent to the applied radiation, making the photo-initiated polymerization approach possible, without coating removal. Moreover, this feature makes the visualization during filling process as well observation of the obtained MSP easy. Chapter 4 shows results obtained for quality evaluation of the MSP taking into account permeability, mechanical resistance and electrochromatographic properties. The solvent quantity used for sol preparation is related with the permeability of the MSP obtained. The electrochromatographic behavior was tested by means of separation of a standard mixture containing propylbenzene, phenanthrene and pyrene in monolithic columns with a 125 µm internal diameter. Chapter 5 describes the UV-Vis chamber assembly equipped with black and white fluorescent lamps used for the photo-initiated polymerization. Some advantages of this homemade photochemical reactor are the following: low-cost (about US$ 150.00), taking into account that all parts can be easily purchased in the local market; simple adaptations can be done in accordance with convenience and the purposes of the system; the bottom part is mobile, so the sample can be placed at different heights from the emission sources. The chamber assembly showed in this work is a great alternative for groups interested in this kind of instrument which do not have many financial resources. In Chapter 6, the aspects and conclusions obtained during project execution are discussed. Appendix A shows some experimental results obtained for the preparation of MSP by thermal polymerization.
4

Metodologia analítica para determinação de triclosan e clorofenois por cromatografia a líquido de alta eficiência (HPLC) e cromatografia por injeção seqüencial (SIC) com uso de coluna monolítica e empacotada / Methodologies for the determination of triclosan and chlorophenols by high performance liquid chromatography (HPLC) and sequential injection chromatography (SIC) using packed and monolithic columns

Garcia, Ausberta Jesús Cabezas 06 December 2011 (has links)
Foram desenvolvidas metodologias de cromatografia a líquido de fase reversa baseadas em injeção sequencial (SIC) e em cromatografia a líquido de alta eficiência (HPLC) para determinação de triclosan em amostras de produtos de higiene pessoal e em estudos de adsorção em argilominerais naturais e modificados, visando determinar parâmetros de adsorção de triclosan frente a alguns de seus metabólitos. A determinação de triclosan em enxaguadores bucais foi realizada por SIC com eluição isocrática usando fase móvel constituída por acetonitrila: tampão fosfato de trietilamina 70 mM pH 3,5 na proporção 70:30 (v v-1), obtendo-se limites de detecção e de quantificação de 0,22 e 0,72 mg L-1, respectivamente. Taxas de recuperação entre 96 e 98% foram obtidas da aplicação a amostras reais, sendo que os resultados obtidos pelo método proposto não apresentaram evidências de diferenças estatisticamente significativas em comparação a uma metodologia de referência baseada em HPLC com coluna empacotada. A separação de triclosan (TCS), 2-clorofenol (2-CP), 2,4-diclorofenol (2,4-DCP), 2,4,6-triclorofenol (2,4,6-TCP), 2,3,4-triclorofenol (2,3,4-TCP) e metiltriclosan (MTCS) foi estudada por SIC, obtendo-se a separação de TCS, 2-CP, 2,4-DCP e 2,4,6-TCP com duas etapas de eluição isocrática, a primeira delas com fase móvel 60:40 (v v-1) metanol: tampão acetato de amônio 20 mM (pH 5,5) seguida de eluição com fase móvel 70:30 (v v-1) metanol : tampão acetato de amônio 20 mM (pH 5,5). Nesse caso, os isômeros 2,4,6-TCP e 2,3,4-TCP coeluem. Metiltriclosan, o menos polar desses compostos, pode ser separado de TCS com etapas subseqüentes de eluição. Os métodos foram aplicados para estudar a adsorção de triclosan e seus metabólitos 2,4-DCP, 2,4,6-TCP e metiltriclosan em montmorilonita homoiônica (K+) e modificada com sal de hexadeciltrimetilamônio (HDTMA), observando-se forte adsorção de triclosan e metiltriclosan em comparação a 2-CP, 2,4-DCP e 2,4,6-TCP. A incorporação de HDTMA no argilomineral causou significativo aumento da capacidade de adsorção desses metabólitos, determinada a partir do ajuste dos dados experimentais à equação linearizada de Langmuir, observando-se que a ordem de adsorção é 2,4,6-TCP > 2,4-DCP > 2-CP / Reversed-phase liquid chromatography methodologies based on sequential injection (SIC) and high performance liquid chromatography (HPLC) have been developed for determination of triclosan in samples of personal hygiene products and in studies of adsorption on natural and modified clay minerals aiming to determine kinetic and thermodynamic parameters of adsorption of triclosan in comparison with some of its metabolites. The determination of triclosan in oral rinses with SIC was performed by isocratic elution using a mobile phase of acetonitrile : 70 mM triethylamine phosphate buffer pH 3.5 at the ratio 70:30 (v v-1), obtaining limits of detection and quantification of 0.22 and 0.72 mg L-1, respectively. Recovery rates between 96 and 98 % were obtained from the application to commercial samples, and the results obtained by the proposed method showed no evidence of statistically significant differences compared to the reference methodology based on HPLC with packed column. The separation of triclosan (TCS), 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4 trichlorophenol (2,3,4-TCP) and methyltriclosan (MTCS) was studied by SIC, resulting in the separation of TCS, 2-CP, 2,4-DCP and 2,4,6-TCP with two isocratic elution steps, the first of them with a mobile phase 60:40 (v v-1) methanol: 20 mM ammonium acetate buffer (pH 5.5) followed by elution with 70:30 (v v-1) mobile phase of methanol : 20 mM ammonium acetate buffer (pH 5.5). In this case, the isomers 2,4,6-TCP and 2,3,4-TCP coeluted. Methyltriclosan, the less polar of these compounds, can be separated from TCS with subsequent elution steps. The methods were applied to study the adsorption of triclosan and its metabolites 2-CP, 2,4-DCP, 2,4,6-TCP and methyltriclosan on homoionic montmorillonite (K+) as well as in hexadecyltrimethylammonium salt (HDTMA) modified montmorillonite, noticing a stronger adsorption of triclosan and methyltriclosan compared with 2-CP, 2,4-DCP and 2,4,6-TCP. Incorporation of HDTMA in the clay mineral caused significant increase in adsorption capacity of these metabolites. This capacity was determined by fitting the experimental data to the linearized Langmuir equation. The adsorption order was 2,4,6-TCP > 2,4-DCP > 2-CP.
5

Estratégias para aumento de sensibilidade e seletividade de separações cromatográficas em sistemas de análises em fluxo / Strategies to improve sensitivity and selectivity of chromatographic separations in flow analysis systems

Batista, Alex Domingues 10 December 2014 (has links)
A introdução de separações cromatográficas expandiu a aplicabilidade de sistemas de análises em fluxo. No entanto, a seletividade e sensibilidade de procedimentos são restritos devido à escassa disponibilidade de fases estacionárias que operam a baixas pressões. Sendo assim, foram desenvolvidos quatro procedimentos analíticos visando a melhoria destes aspectos. A primeira proposta explorou pioneiramente colunas de núcleo fundido em sistemas de análises por injeção em fluxo. A separação de metil, etil e propil parabenos foi selecionada com aplicação. As eficiências cromatográficas de quatro colunas (C18, RPamida, F5 e fenil-hexil) foram avaliadas criticamente. Acetonitrila e uma solução de ácido fosfórico pH 2,5 foram utilizadas como fase móvel. A fase RP-amida apresentou melhor desempenho com a separação dos três analitos em 8,0 min, com resoluções > 1,72, simetrias de pico < 1,66, LOD entre 0,12 e 0,39 mg L-1, resposta linear até 5,0 mg L-1 (r > 0,996) e CV para altura dos picos < 3,5 % (n=10). O procedimento foi aplicado à determinação de parabenos em produtos de cuidados pessoais e os resultados concordaram com o procedimento de referência a 95% de confiança. Um procedimento envolvendo o acoplamento de extração em fase sólida (SPE) a um sistema de cromatografia por injeção sequencial (SIC) foi proposto para pré-concentração e separação de oito sulfonamidas. A fase estacionária pentafluorofenilpropil foi selecionada após comparação crítica da eficiência apresentada por três colunas de núcleo fundido e duas colunas de fases monolíticas. Acetonitrila e tampão fosfato (pH 5,0) foram utilizados como fase. Fatores de enriquecimento de até 39,2 foram alcançados com volume de amostra de 500 ?L. O procedimento apresentou tempo de análise < 10,5 min, resoluções > 1,83 com simetrias de pico <= 1,52, LOD entre 4,9 e 27 ?g L-1, faixa de resposta linear entre 30,0 e 1000,0 ?g L-1 (r > 0,997) e CV da altura dos picos, 2,9% (n=6). Um procedimento empregando fase estacionária micelar foi desenvolvido para determinação de melamina em leite. A fase móvel foi composta por uma solução aquosa de dodecil sulfato de sódio (SDS) e 1-propanol (92,5:7,5 v/v). O procedimento de preparo de amostra foi implementado em linha pela diluição da amostra com SDS. Resposta linear foi observada entre 2,0 e 6,0 mg L-1 de melamina com LOD estimado em 0,6 mg L-1 e CV da altura dos picos de 2,9% (n=6). Os resultados para diferentes amostras de leite foram concordantes com aqueles obtidos pelo procedimento cromatográfico de referência em um nível de 95% de confiança. Uma estratégia envolvendo pré-concentração on-column de parabenos em um sistema SIC foi proposta. Resposta linear foi observada entre 0,25 e 1,00 ?g mL-1 (r >= 0,999) e LODs estimados entre 40 e 60 ng mL-1. Tempos de retenção e altura dos picos apresentaram CV < 2,1%. Fatores de enriquecimento entre 30,0 e 34,8 foram alcançados. As estratégias propostas são viáveis para melhoria de seletividade e sensibilidade de separações cromatográficas em sistemas de análises em fluxo, além de apresentarem vantagens frente a procedimentos análogos na literatura / The introduction of chromatographic separations expanded the applicability of flow systems. However, selectivity and sensitivity of the procedures are limited due the poor options of stationary phases available for low-pressure. Therefore, four procedures were developed aiming the improvement of these aspects. The first proposal exploited pioneered fused-core columns in a flow injection analysis system. The separation of methyl, ethyl and propel parabens was selected as an application. The chromatographic efficiency of four columns (C18, RP-amide, F5 and fenyl-hexyl) were crítically evaluated. Acetonitrile and a phosphoric acid solution at pH 2.5 were used as mobile phase at different proportions for each column. The RP-amide phase presented the best performance by separating the analytes in 8.0 min with resolution > 1.72, peak symmetry < 1.66, LOD between 0.12-0.39 mg L-1, linear response range up to 5.0 mg L-1 (r > 0.996) and coefficients of variation of peak heights < 3.5% (n=10). The procedure was applied to parabens determination in personal care products and the results agreed with the HPLC reference procedure at the 95% confidence level. A procedure coupling solid phase extraction (SPE) to a sequential injection chromatography (SIC) was proposed for preconcentration and separation of eight sulfonamides. The pentafluorophenylpropyl (F5) phase was selected after a critical comparison of the performance achieved by three fused-core columns and two monolithic columns. Acetonitrile and acetate buffer pH 5.0 were used as mobile phase. Enrichment factors up to 39.2 were achieved with a 500 ?L sample volume. The developed procedure showed analysis time < 10.5 min, resolutions > 1.83 with peak symmetry <= 1.52, LODs between 4.9 and 27 ?g L-1, linear response ranges from 30.0 to 1000.0 ?g L-1 (r > 0.997) and CV of peak heights < 2.9% (n=6). Micelar chromatography was for the first time exploited in SIC and the performance was demonstrated by determination of melamine in milk. Mobile phase was composed by a sodium dodecyl sulfate (SDS) solution and propanol (92.5:7.5). The sample pretreatment procedure was on-line implemented by dilution of the sample with SDS. A linear response was observed within 2.0 and 6.0 mg L-1 of melamine with a LOD estimated at 0.6 mg L-1 and coefficients of variation at 2.9% (n=6). Results for different milk samples agreed with those obtained by high performance liquid chromatography at the 95% confidence level. A procedure involved on-column preconcentration of parabens in a SIC system was based on the injection of relatively high volume of an aqueous sample in a reversed-phase column. After preconcentration, a suitable mobile phase was inserted to perform chromatographic separation (acetonitrile/phosphoric acid pH 2.5 (75:25, v/v)). A linear response was achieved from 0.25 to 1.00 ?g mL-1 (r > 0.999) and LOD estimated within 40 and 80 ng mL-1. Coefficients of variation for retention time and peak heights were below 2.1%. Enrichment factors within 30.0 and 34.8 were achieved. The proposed strategies are feasible for improving selectivity and sensitivity of chromatographic separations in flow analysis systems, besides having advantages compared to similar procedures in the literature
6

Metodologia analítica para determinação de triclosan e clorofenois por cromatografia a líquido de alta eficiência (HPLC) e cromatografia por injeção seqüencial (SIC) com uso de coluna monolítica e empacotada / Methodologies for the determination of triclosan and chlorophenols by high performance liquid chromatography (HPLC) and sequential injection chromatography (SIC) using packed and monolithic columns

Ausberta Jesús Cabezas Garcia 06 December 2011 (has links)
Foram desenvolvidas metodologias de cromatografia a líquido de fase reversa baseadas em injeção sequencial (SIC) e em cromatografia a líquido de alta eficiência (HPLC) para determinação de triclosan em amostras de produtos de higiene pessoal e em estudos de adsorção em argilominerais naturais e modificados, visando determinar parâmetros de adsorção de triclosan frente a alguns de seus metabólitos. A determinação de triclosan em enxaguadores bucais foi realizada por SIC com eluição isocrática usando fase móvel constituída por acetonitrila: tampão fosfato de trietilamina 70 mM pH 3,5 na proporção 70:30 (v v-1), obtendo-se limites de detecção e de quantificação de 0,22 e 0,72 mg L-1, respectivamente. Taxas de recuperação entre 96 e 98% foram obtidas da aplicação a amostras reais, sendo que os resultados obtidos pelo método proposto não apresentaram evidências de diferenças estatisticamente significativas em comparação a uma metodologia de referência baseada em HPLC com coluna empacotada. A separação de triclosan (TCS), 2-clorofenol (2-CP), 2,4-diclorofenol (2,4-DCP), 2,4,6-triclorofenol (2,4,6-TCP), 2,3,4-triclorofenol (2,3,4-TCP) e metiltriclosan (MTCS) foi estudada por SIC, obtendo-se a separação de TCS, 2-CP, 2,4-DCP e 2,4,6-TCP com duas etapas de eluição isocrática, a primeira delas com fase móvel 60:40 (v v-1) metanol: tampão acetato de amônio 20 mM (pH 5,5) seguida de eluição com fase móvel 70:30 (v v-1) metanol : tampão acetato de amônio 20 mM (pH 5,5). Nesse caso, os isômeros 2,4,6-TCP e 2,3,4-TCP coeluem. Metiltriclosan, o menos polar desses compostos, pode ser separado de TCS com etapas subseqüentes de eluição. Os métodos foram aplicados para estudar a adsorção de triclosan e seus metabólitos 2,4-DCP, 2,4,6-TCP e metiltriclosan em montmorilonita homoiônica (K+) e modificada com sal de hexadeciltrimetilamônio (HDTMA), observando-se forte adsorção de triclosan e metiltriclosan em comparação a 2-CP, 2,4-DCP e 2,4,6-TCP. A incorporação de HDTMA no argilomineral causou significativo aumento da capacidade de adsorção desses metabólitos, determinada a partir do ajuste dos dados experimentais à equação linearizada de Langmuir, observando-se que a ordem de adsorção é 2,4,6-TCP > 2,4-DCP > 2-CP / Reversed-phase liquid chromatography methodologies based on sequential injection (SIC) and high performance liquid chromatography (HPLC) have been developed for determination of triclosan in samples of personal hygiene products and in studies of adsorption on natural and modified clay minerals aiming to determine kinetic and thermodynamic parameters of adsorption of triclosan in comparison with some of its metabolites. The determination of triclosan in oral rinses with SIC was performed by isocratic elution using a mobile phase of acetonitrile : 70 mM triethylamine phosphate buffer pH 3.5 at the ratio 70:30 (v v-1), obtaining limits of detection and quantification of 0.22 and 0.72 mg L-1, respectively. Recovery rates between 96 and 98 % were obtained from the application to commercial samples, and the results obtained by the proposed method showed no evidence of statistically significant differences compared to the reference methodology based on HPLC with packed column. The separation of triclosan (TCS), 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4 trichlorophenol (2,3,4-TCP) and methyltriclosan (MTCS) was studied by SIC, resulting in the separation of TCS, 2-CP, 2,4-DCP and 2,4,6-TCP with two isocratic elution steps, the first of them with a mobile phase 60:40 (v v-1) methanol: 20 mM ammonium acetate buffer (pH 5.5) followed by elution with 70:30 (v v-1) mobile phase of methanol : 20 mM ammonium acetate buffer (pH 5.5). In this case, the isomers 2,4,6-TCP and 2,3,4-TCP coeluted. Methyltriclosan, the less polar of these compounds, can be separated from TCS with subsequent elution steps. The methods were applied to study the adsorption of triclosan and its metabolites 2-CP, 2,4-DCP, 2,4,6-TCP and methyltriclosan on homoionic montmorillonite (K+) as well as in hexadecyltrimethylammonium salt (HDTMA) modified montmorillonite, noticing a stronger adsorption of triclosan and methyltriclosan compared with 2-CP, 2,4-DCP and 2,4,6-TCP. Incorporation of HDTMA in the clay mineral caused significant increase in adsorption capacity of these metabolites. This capacity was determined by fitting the experimental data to the linearized Langmuir equation. The adsorption order was 2,4,6-TCP > 2,4-DCP > 2-CP.
7

Estratégias para aumento de sensibilidade e seletividade de separações cromatográficas em sistemas de análises em fluxo / Strategies to improve sensitivity and selectivity of chromatographic separations in flow analysis systems

Alex Domingues Batista 10 December 2014 (has links)
A introdução de separações cromatográficas expandiu a aplicabilidade de sistemas de análises em fluxo. No entanto, a seletividade e sensibilidade de procedimentos são restritos devido à escassa disponibilidade de fases estacionárias que operam a baixas pressões. Sendo assim, foram desenvolvidos quatro procedimentos analíticos visando a melhoria destes aspectos. A primeira proposta explorou pioneiramente colunas de núcleo fundido em sistemas de análises por injeção em fluxo. A separação de metil, etil e propil parabenos foi selecionada com aplicação. As eficiências cromatográficas de quatro colunas (C18, RPamida, F5 e fenil-hexil) foram avaliadas criticamente. Acetonitrila e uma solução de ácido fosfórico pH 2,5 foram utilizadas como fase móvel. A fase RP-amida apresentou melhor desempenho com a separação dos três analitos em 8,0 min, com resoluções > 1,72, simetrias de pico < 1,66, LOD entre 0,12 e 0,39 mg L-1, resposta linear até 5,0 mg L-1 (r > 0,996) e CV para altura dos picos < 3,5 % (n=10). O procedimento foi aplicado à determinação de parabenos em produtos de cuidados pessoais e os resultados concordaram com o procedimento de referência a 95% de confiança. Um procedimento envolvendo o acoplamento de extração em fase sólida (SPE) a um sistema de cromatografia por injeção sequencial (SIC) foi proposto para pré-concentração e separação de oito sulfonamidas. A fase estacionária pentafluorofenilpropil foi selecionada após comparação crítica da eficiência apresentada por três colunas de núcleo fundido e duas colunas de fases monolíticas. Acetonitrila e tampão fosfato (pH 5,0) foram utilizados como fase. Fatores de enriquecimento de até 39,2 foram alcançados com volume de amostra de 500 ?L. O procedimento apresentou tempo de análise < 10,5 min, resoluções > 1,83 com simetrias de pico <= 1,52, LOD entre 4,9 e 27 ?g L-1, faixa de resposta linear entre 30,0 e 1000,0 ?g L-1 (r > 0,997) e CV da altura dos picos, 2,9% (n=6). Um procedimento empregando fase estacionária micelar foi desenvolvido para determinação de melamina em leite. A fase móvel foi composta por uma solução aquosa de dodecil sulfato de sódio (SDS) e 1-propanol (92,5:7,5 v/v). O procedimento de preparo de amostra foi implementado em linha pela diluição da amostra com SDS. Resposta linear foi observada entre 2,0 e 6,0 mg L-1 de melamina com LOD estimado em 0,6 mg L-1 e CV da altura dos picos de 2,9% (n=6). Os resultados para diferentes amostras de leite foram concordantes com aqueles obtidos pelo procedimento cromatográfico de referência em um nível de 95% de confiança. Uma estratégia envolvendo pré-concentração on-column de parabenos em um sistema SIC foi proposta. Resposta linear foi observada entre 0,25 e 1,00 ?g mL-1 (r >= 0,999) e LODs estimados entre 40 e 60 ng mL-1. Tempos de retenção e altura dos picos apresentaram CV < 2,1%. Fatores de enriquecimento entre 30,0 e 34,8 foram alcançados. As estratégias propostas são viáveis para melhoria de seletividade e sensibilidade de separações cromatográficas em sistemas de análises em fluxo, além de apresentarem vantagens frente a procedimentos análogos na literatura / The introduction of chromatographic separations expanded the applicability of flow systems. However, selectivity and sensitivity of the procedures are limited due the poor options of stationary phases available for low-pressure. Therefore, four procedures were developed aiming the improvement of these aspects. The first proposal exploited pioneered fused-core columns in a flow injection analysis system. The separation of methyl, ethyl and propel parabens was selected as an application. The chromatographic efficiency of four columns (C18, RP-amide, F5 and fenyl-hexyl) were crítically evaluated. Acetonitrile and a phosphoric acid solution at pH 2.5 were used as mobile phase at different proportions for each column. The RP-amide phase presented the best performance by separating the analytes in 8.0 min with resolution > 1.72, peak symmetry < 1.66, LOD between 0.12-0.39 mg L-1, linear response range up to 5.0 mg L-1 (r > 0.996) and coefficients of variation of peak heights < 3.5% (n=10). The procedure was applied to parabens determination in personal care products and the results agreed with the HPLC reference procedure at the 95% confidence level. A procedure coupling solid phase extraction (SPE) to a sequential injection chromatography (SIC) was proposed for preconcentration and separation of eight sulfonamides. The pentafluorophenylpropyl (F5) phase was selected after a critical comparison of the performance achieved by three fused-core columns and two monolithic columns. Acetonitrile and acetate buffer pH 5.0 were used as mobile phase. Enrichment factors up to 39.2 were achieved with a 500 ?L sample volume. The developed procedure showed analysis time < 10.5 min, resolutions > 1.83 with peak symmetry <= 1.52, LODs between 4.9 and 27 ?g L-1, linear response ranges from 30.0 to 1000.0 ?g L-1 (r > 0.997) and CV of peak heights < 2.9% (n=6). Micelar chromatography was for the first time exploited in SIC and the performance was demonstrated by determination of melamine in milk. Mobile phase was composed by a sodium dodecyl sulfate (SDS) solution and propanol (92.5:7.5). The sample pretreatment procedure was on-line implemented by dilution of the sample with SDS. A linear response was observed within 2.0 and 6.0 mg L-1 of melamine with a LOD estimated at 0.6 mg L-1 and coefficients of variation at 2.9% (n=6). Results for different milk samples agreed with those obtained by high performance liquid chromatography at the 95% confidence level. A procedure involved on-column preconcentration of parabens in a SIC system was based on the injection of relatively high volume of an aqueous sample in a reversed-phase column. After preconcentration, a suitable mobile phase was inserted to perform chromatographic separation (acetonitrile/phosphoric acid pH 2.5 (75:25, v/v)). A linear response was achieved from 0.25 to 1.00 ?g mL-1 (r > 0.999) and LOD estimated within 40 and 80 ng mL-1. Coefficients of variation for retention time and peak heights were below 2.1%. Enrichment factors within 30.0 and 34.8 were achieved. The proposed strategies are feasible for improving selectivity and sensitivity of chromatographic separations in flow analysis systems, besides having advantages compared to similar procedures in the literature

Page generated in 0.0789 seconds