Spelling suggestions: "subject:"complexantes orgânica"" "subject:"complexante orgânica""
1 |
Desenvolvimento e validação de métodos voltamétricos sequenciais para a determinação de elementos em matrizes complexas / Development and validation of voltammetric sequential methods for the determination of elements in complex matricesMuratt, Diana Tomazi 07 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Toxic elements are in continuous accumulation in the environment mainly due to anthropogenic activities. In this work, a voltammetric method of sequential analysis for application in matrices of complex characteristics was developed. Using an organic mixture complexing, SVRS (alizarin violet) DMG (dimethylglyoxime), 8-hydroxyquinoline (oxine), CA (chloranilic acid) and DTPA (diethylenetriaminepentaacetic acid) 13 elements could be determined at two different methods. According to the formation constants with their respective ligands, in method 1, step were determined Al3+, Fe3+, Mo6+ SVRS in the presence of AdSV (Adsorptive Stripping Voltammetry). In step 2 were determined Zn2+, Cd2+, Pb2+ and Cu2+ by ASV. In step 3, were determined Ni2+ and Co2+ in the presence of DMG and oxine. In method 2, V5+ and U6+ were determined by AdSV in the presence of CA (chloranilic acid), Cr(total) was analyzed in sequence by the presence of DTPA by AdSV and finally Tl+ was determined by ASV. The data for the figures of merit showed that the proposed method is suitable for samples of complex matrices studied (certified materials and commercial plant compounds). High concentrations for some elements were found in commercial samples. It indicates that the species translocates through the environment in which they are insert, being susceptible to contact with humans. / Elementos tóxicos estão em contínuo acúmulo no ambiente principalmente devido a atividades antropogênicas. Neste trabalho, foi desenvolvido um método voltamétrico de análise sequencial para aplicação em matrizes de natureza complexa. Utilizando uma mistura de complexantes orgânicos, SVRS (violeta de solocromo), DMG (dimetilglioxima), 8-Hidroxiquinolina (oxina), CA (ácido cloranílico) e DTPA (ácido dietilenotriamino pentaacético) foi possível determinar 13 elementos em dois diferentes métodos. De acordo com as constantes de formação com os respectivos ligantes foi determinado no método 1, etapa 1 Al3+, Fe3+, Mo6+ na presença de SVRS por AdSV (Adsorptive Stripping Voltammetry). Na etapa 2 determinou-se Zn2+, Cd2+, Pb2+, Cu2+ por ASV. Na etapa 3, foram determinados Ni2+ e Co2+, na presença de DMG e oxina. No método 2, U6+ e V5+ foram determinados por AdSV na presença de CA (ácido cloranílico), Cr(total) foi determinado na sequência na presença de DTPA por AdSV e por fim, Tl+ foi determinado por ASV. Os dados obtidos para as figuras de mérito mostraram que o método proposto é adequado para as amostras de matrizes complexas estudadas (materiais certificados e compostos vegetais comerciais). Concentrações altas para alguns elementos foram encontradas nas amostras comerciais. Este dado indica que as espécies translocam-se através do meio em que estão inseridos estando suscetíveis a entrar em contato com o ser humano.
|
2 |
Tratamento de efluente de indústria têxtil utilizando processos químicos avançados via reações de fenton modificadas / Treating effluent from the textile industry processes using advanced chemical reactions via Fenton modifiedAlmeida, Alcione Aparecida de 15 February 2013 (has links)
Made available in DSpace on 2017-07-10T18:07:56Z (GMT). No. of bitstreams: 1
Alcione Aparecida de Almeida.pdf: 1918947 bytes, checksum: d5a1da74fcba2bfdd180c1594dcd456b (MD5)
Previous issue date: 2013-02-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study was to evaluate the modified Fenton reactions (RFM), through the addition of six complexing organic separately in each reaction, these being: ascorbic acid (AA), citric acid (CA), ethylenediaminetetraacetic acid (EDTA), gluconic acid (AG), oxalic acid (OA) and tartaric acid (TA), the degradation of textile effluent under varying molar ratios between the total organic carbon, [Fe2+], complexing and [H2O2]. In RFM and Fenton reactions (RF) reactor was used consisting of a borosilicate beaker with a maximum volume of 250 mL, in batch, open, without stirring under room temperature in the optimization phase of time aliquots were removed in the effluent times: 0, 3, 6, 9, 12, 15, 18, 21 and 24 h. The procedure consisted of addition of 250 mL of textile effluent to the reactor for RF and RFM, followed by the oxidant and a catalyst for the RF and oxidizing catalyst and complexing to RFM. RF best results in reduction of TOC was obtained in 12 h treatment under initial pH value of 3.0 and a molar ratio [1:0,9:27,5]. Concerning the [COT:Fe2+:H2O2] where noted a reduction of 91.06% of TOC, COD 94.51%, 99.88% and 99.02% of the turbidity of discoloration. The RFM showed the best results with the use of complexing GA at 15 h of treatment under molar ratio [1:1,31:1,12:27,94], its [COT:Fe2+:AG:H2O2] which promoted reduction of 82.30% of TOC, COD 90.53%, 99.27% and 99.19% of the turbidity of discoloration, TA had similar results in reduction of parameters when the effluent subjected to 12 h of treatment in a molar ratio [1:0,76:0,94:32,13]. Concerning the [COT:Fe2+:AT:H2O2] under these conditions was possible to reduce 75.05% TOC, 94.89% COD, 97.84% turbidity and discoloration of 96.75%. However, RF are effective in the treatment of textile effluents, though the RFM presented as a new possibility of the treatment without the necessity of adjusting the initial pH value. / Este estudo teve por objetivo avaliar as reações de Fenton modificadas (RFM), através da adição de seis complexantes orgânicos isoladamente em cada reação, sendo estes: ácido ascórbico (AA), ácido cítrico (AC), ácido etilenodiaminotetracético (EDTA), ácido glucônico (AG), ácido oxálico (AO) e ácido tartárico (AT), na degradação de efluente têxtil, sob variadas relações molares entre o carbono orgânico total, [Fe2+], complexante e o [H2O2]. Nas RFM e reações de Fenton (RF) foi utilizado reator constituído por um béquer de borossilicato com volume máximo de 250 mL, em sistema descontínuo, aberto, sem agitação, sob temperatura ambiente, na fase de otimização do tempo alíquotas do efluente eram retiradas nos tempos: 0, 3, 6, 9, 12, 15, 18, 21 e 24 h. O procedimento consistiu na adição de 250 mL do efluente têxtil ao reator para as RF e RFM, seguido do oxidante e catalisador para as RF e oxidante, catalisador e complexante para as RFM. Nas RF os melhores resultados de redução do COT foi obtido em 12 h de tratamento, sob valor de pH inicial 3,0 e relação molar [1:0,9:27,5] referente ao [COT:Fe2+:H2O2] aonde constatou-se redução de 91,06% do COT, 94,51 da DQO, 99,88 da turbidez e 99,02% de descoloração. As RFM apresentaram os melhores resultados com a utilização do complexante AG em 15 h de tratamento sob relação molar [1:1,31:1,12:27,94], respectivo [COT:Fe2+:AG:H2O2] a qual promoveu a redução de 82,30% do COT, 90,53% da DQO, 99,27% da turbidez e 99,19% de descoloração, o AT apresentou resultados similares de redução dos parâmetros avaliados, quando submetido o efluente a 12 h de tratamento sob relação molar [1:0,76:0,94:32,13] referente ao [COT:Fe2+:AT:H2O2], nestas condições foi possível a redução de 75,05% do COT, 94,89% da DQO, 97,84% da turbidez e descoloração de 96,75%. Contudo, as RF são eficazes no tratamento de efluentes têxteis, entretanto as RFM apresentam-se como uma nova possibilidade de tratamento sem a necessidade de ajuste do valor do pH inicial.
|
Page generated in 0.0868 seconds