• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desnitrificação autotrófica de efluente avícola em reator de leito fixo de calcário dolomítico e enxofre elementar / Autotrophic denitrification of poultry effluent in fixed bed reactor of dolomitic limestone and elemental sulfur

Model, Adriana Neres de Lima 16 February 2016 (has links)
Made available in DSpace on 2017-07-10T19:24:07Z (GMT). No. of bitstreams: 1 Adriana_ Neres de Lima Model.pdf: 1114285 bytes, checksum: 5ac5451e63a53706eccc865aabd911c5 (MD5) Previous issue date: 2016-02-16 / Nitrification associated to autotrophic denitrification, up from an elemental sulfur as an electron donor, can be an adequate option during the post-treatment of anaerobic effluent, which contains ammoniacal nitrogen that should be nitrified, and whose low carbon concentrations (C/N<5) make heterotrophic denitrification difficult. Due to the alkalinity consumption in both processes, lime materials can be applied as alkalizing to ensure the nitrogen removal efficiencies. Therefore, based on this finding, this research has proposed nitrification application followed by autotrophic denitrification in a single reactor containing elemental sulfur and dolomitic limestone to remove nitrogen from an anaerobic effluent from a cold storage from poultry industry. Thus, this study was divided into three steps due to some gaps in literature on the application of autotrophic denitrification up from elemental sulfur in real effluents. In the first step, the performance of autotrophic denitrification was evaluated in four anoxic fixed-bed reactors of elemental sulfur and dolomitic lime at 4:0, 3:1, 1:1 and 1:3 ratios. The reactors were submitted to constant nitrogen feed load (0.114 kg N m³ -1 d-1) under five initial alkalinity conditions (1,000, 800, 600, 400 and 200 mg CaCO3 L-1). The reactors showed similar behavior under those five evaluated experimental conditions. The greatest denitrification efficiencies (from 84.8 to 94.9%) were observed in the first three conditions, whose denitrification rate was 0.102 ± 0.002 kg NOx m³ -1 d-1 and apparent consumption of alkalinity superior to 244.8 mg CaCO3 L-1. Denitrification efficiencies tended to decrease due to the decrease in the initial concentration of alkalinity up from the third experimental condition (600 mg CaCO3 L-1) due to an excessive consumption and inadequate increase of alkalinity (< 180 mg CaCO3 L-1) from dolomitic limestone. During the second step, the anoxic reactor with bed composition (1: 3 ratio), whose initial alkalinity condition was 600 mg CaCO3 L-1, operated at 14, 10 and 6 h HRT. The reactor showed denitrification efficiencies of 94.4 ± 2.0; 94.9 ± 2; 71.1 ± 7.8% as well as denitrification rates of 0.115 ± 0.007; 0.164 ± 0.007 and 0.217 ± 0.025 kg NOx m³ -1 d-1 for HDT of 14, 10 and 6 hours, respectively. At the sixth hour-HRT, the applied overload and limited mass transfer may have contributed to performance decrease into the reactor due to the accumulation of gases in the bed. The third step approached about feeding strategies with mixing ammonified as well as nitrified one in different rates 1:3 (E1), 1:1 (E2) and 3:1 (E3) in anoxic-aerobic reactor of fixed bed with elemental sulfur: dolomitic limestone 1: 3, under 1,000 mg CaCO3 L-1 initial condition of alkalinity. The reactor presented some efficiencies of ammoniacal and total nitrogen removal of 67.3 ± 6.4 and 64.2 ± 6.3% for E1 condition, 63.4 ± 6.4 and 53.1 ± 7.1% for E2 and 14.2 ± 4.4 and 33.8 ± 1.7% for E3. The generation of hydrogen sulfide mainly from sulfur imbalance effect in anoxic compartment may have contributed to a partial inhibition of nitrifying bacteria. The difficulty in keeping the nitrification process was characterized as a limiting factor during nitrogen removal. Low total nitrogen removal efficiencies have implied that nitrification followed by autotrophic denitrification from elemental sulfur in a single reactor was inadequate to remove nitrogenous compounds of anaerobic effluent from a cold storage from poultry industry / A nitrificação acoplada à desnitrificação autotrófica, a partir do enxofre elementar como doador de elétrons, pode ser uma opção adequada no pós-tratamento de efluentes anaeróbios, os quais contêm nitrogênio amoniacal que deve ser nitrificado, cujas baixas concentrações de carbono (C/N<5) dificultam a desnitrificação heterotrófica. Devido ao consumo de alcalinidade nos dois processos, materiais calcários podem ser utilizados como alcalinizantes para garantir as eficiências de remoção do nitrogênio. Com base nessa constatação, esta pesquisa propôs a aplicação da nitrificação seguida da desnitrificação autotrófica em único reator contendo enxofre elementar e calcário dolomítico na remoção de nitrogênio de efluente anaeróbio proveniente de frigorífico avícola. Devido às lacunas presentes na literatura sobre a aplicação da desnitrificação autotrófica a partir do enxofre elementar em efluentes reais, esse estudo foi dividido em três etapas. Na primeira etapa, avaliou-se o desempenho da desnitrificação autotrófica em quatro reatores anóxicos de leito fixo de enxofre elementar e calcário dolomítico nas proporções de 4:0, 3:1, 1:1 e 1:3. Os reatores foram submetidos à alimentação de carga nitrogenada constante de 0,114 kg N m³ -1 d-1 em cinco condições de alcalinidade inicial (1000, 800, 600, 400 e 200 mg CaCO3 L-1). Os reatores apresentaram comportamento semelhante nas cinco condições experimentais avaliadas. As maiores eficiências de desnitrificação (entre 84,8 e 94,9%) foram observadas nas três primeiras condições, com taxa de desnitrificação de 0,102±0,002 kg NOx m³ -1 d-1 e consumo aparente de alcalinidade superior a 244,8 mg CaCO3 L-1. As eficiências de desnitrificação tenderam a diminuir em função do decréscimo da alcalinidade inicial a partir da terceira condição experimental (600 mg CaCO3 L-1) devido ao consumo excessivo e ao incremento insuficiente de alcalinidade (<180 mg CaCO3 L-1) a partir do calcário dolomítico. Na segunda etapa, o reator anóxico com composição de leito na relação de 1:3, em condição inicial de alcalinidade de 600 mg CaCO3 L-1, foi operado em TDH de 14, 10 e 6 horas. O reator apresentou eficiências de desnitrificação de 94,4±2,0 e 94,9±2 e 71,1±7,8% e taxas de desnitrificação de 0,115±0,007, 0,164±0,007 e 0,217±0,025 kg NOx m³ -1 d-1 para os TDH de 14, 10 e 6 horas, respectivamente. No TDH de 6 horas, a sobrecarga aplicada e a limitada transferência de massa, devido ao acúmulo de gases no leito, podem ter contribuído para diminuição do desempenho do reator. A terceira etapa abordou estratégias de alimentação com mistura de efluentes amonificado e nitrificado em diferentes proporções de 1:3 (E1), 1:1 (E2) e 3:1 (E3) em reator anóxico-aeróbio de leito fixo de enxofre elementar: calcário dolomítico de 1:3 em condição inicial de alcalinidade de 1000mg CaCO3L-1. O reator apresentou eficiências de remoção de nitrogênio amoniacal e total de 67,3±6,4 e 64,2±6,3% para a condição E1, 63,4±6,4 e 53,1±7,1% para E2 e 14,2±4 e 33,8±1,7% para E3. A geração de sulfeto de hidrogênio a partir, principalmente, do efeito de desproporção do enxofre no compartimento anóxico, pode ter contribuído para a inibição parcial das bactérias nitrificantes. A dificuldade em manter o processo de nitrificação foi caraterizada como fator limitante na remoção de nitrogênio. As baixas eficiências de remoção de nitrogênio total indicaram que a nitrificação seguida da desnitrificação autotrófica, a partir do enxofre elementar em único reator, não foi adequada para remover compostos nitrogenados de efluente anaeróbio de frigorífico avícola
2

Desnitrificação autotrófica de efluente avícola em reator de leito fixo de calcário dolomítico e enxofre elementar / Autotrophic denitrification of poultry effluent in fixed bed reactor of dolomitic limestone and elemental sulfur

Model, Adriana Neres de Lima 16 February 2016 (has links)
Made available in DSpace on 2017-05-12T14:47:24Z (GMT). No. of bitstreams: 1 Adriana_ Neres de Lima Model.pdf: 1114285 bytes, checksum: 5ac5451e63a53706eccc865aabd911c5 (MD5) Previous issue date: 2016-02-16 / Nitrification associated to autotrophic denitrification, up from an elemental sulfur as an electron donor, can be an adequate option during the post-treatment of anaerobic effluent, which contains ammoniacal nitrogen that should be nitrified, and whose low carbon concentrations (C/N<5) make heterotrophic denitrification difficult. Due to the alkalinity consumption in both processes, lime materials can be applied as alkalizing to ensure the nitrogen removal efficiencies. Therefore, based on this finding, this research has proposed nitrification application followed by autotrophic denitrification in a single reactor containing elemental sulfur and dolomitic limestone to remove nitrogen from an anaerobic effluent from a cold storage from poultry industry. Thus, this study was divided into three steps due to some gaps in literature on the application of autotrophic denitrification up from elemental sulfur in real effluents. In the first step, the performance of autotrophic denitrification was evaluated in four anoxic fixed-bed reactors of elemental sulfur and dolomitic lime at 4:0, 3:1, 1:1 and 1:3 ratios. The reactors were submitted to constant nitrogen feed load (0.114 kg N m³ -1 d-1) under five initial alkalinity conditions (1,000, 800, 600, 400 and 200 mg CaCO3 L-1). The reactors showed similar behavior under those five evaluated experimental conditions. The greatest denitrification efficiencies (from 84.8 to 94.9%) were observed in the first three conditions, whose denitrification rate was 0.102 ± 0.002 kg NOx m³ -1 d-1 and apparent consumption of alkalinity superior to 244.8 mg CaCO3 L-1. Denitrification efficiencies tended to decrease due to the decrease in the initial concentration of alkalinity up from the third experimental condition (600 mg CaCO3 L-1) due to an excessive consumption and inadequate increase of alkalinity (< 180 mg CaCO3 L-1) from dolomitic limestone. During the second step, the anoxic reactor with bed composition (1: 3 ratio), whose initial alkalinity condition was 600 mg CaCO3 L-1, operated at 14, 10 and 6 h HRT. The reactor showed denitrification efficiencies of 94.4 ± 2.0; 94.9 ± 2; 71.1 ± 7.8% as well as denitrification rates of 0.115 ± 0.007; 0.164 ± 0.007 and 0.217 ± 0.025 kg NOx m³ -1 d-1 for HDT of 14, 10 and 6 hours, respectively. At the sixth hour-HRT, the applied overload and limited mass transfer may have contributed to performance decrease into the reactor due to the accumulation of gases in the bed. The third step approached about feeding strategies with mixing ammonified as well as nitrified one in different rates 1:3 (E1), 1:1 (E2) and 3:1 (E3) in anoxic-aerobic reactor of fixed bed with elemental sulfur: dolomitic limestone 1: 3, under 1,000 mg CaCO3 L-1 initial condition of alkalinity. The reactor presented some efficiencies of ammoniacal and total nitrogen removal of 67.3 ± 6.4 and 64.2 ± 6.3% for E1 condition, 63.4 ± 6.4 and 53.1 ± 7.1% for E2 and 14.2 ± 4.4 and 33.8 ± 1.7% for E3. The generation of hydrogen sulfide mainly from sulfur imbalance effect in anoxic compartment may have contributed to a partial inhibition of nitrifying bacteria. The difficulty in keeping the nitrification process was characterized as a limiting factor during nitrogen removal. Low total nitrogen removal efficiencies have implied that nitrification followed by autotrophic denitrification from elemental sulfur in a single reactor was inadequate to remove nitrogenous compounds of anaerobic effluent from a cold storage from poultry industry / A nitrificação acoplada à desnitrificação autotrófica, a partir do enxofre elementar como doador de elétrons, pode ser uma opção adequada no pós-tratamento de efluentes anaeróbios, os quais contêm nitrogênio amoniacal que deve ser nitrificado, cujas baixas concentrações de carbono (C/N<5) dificultam a desnitrificação heterotrófica. Devido ao consumo de alcalinidade nos dois processos, materiais calcários podem ser utilizados como alcalinizantes para garantir as eficiências de remoção do nitrogênio. Com base nessa constatação, esta pesquisa propôs a aplicação da nitrificação seguida da desnitrificação autotrófica em único reator contendo enxofre elementar e calcário dolomítico na remoção de nitrogênio de efluente anaeróbio proveniente de frigorífico avícola. Devido às lacunas presentes na literatura sobre a aplicação da desnitrificação autotrófica a partir do enxofre elementar em efluentes reais, esse estudo foi dividido em três etapas. Na primeira etapa, avaliou-se o desempenho da desnitrificação autotrófica em quatro reatores anóxicos de leito fixo de enxofre elementar e calcário dolomítico nas proporções de 4:0, 3:1, 1:1 e 1:3. Os reatores foram submetidos à alimentação de carga nitrogenada constante de 0,114 kg N m³ -1 d-1 em cinco condições de alcalinidade inicial (1000, 800, 600, 400 e 200 mg CaCO3 L-1). Os reatores apresentaram comportamento semelhante nas cinco condições experimentais avaliadas. As maiores eficiências de desnitrificação (entre 84,8 e 94,9%) foram observadas nas três primeiras condições, com taxa de desnitrificação de 0,102±0,002 kg NOx m³ -1 d-1 e consumo aparente de alcalinidade superior a 244,8 mg CaCO3 L-1. As eficiências de desnitrificação tenderam a diminuir em função do decréscimo da alcalinidade inicial a partir da terceira condição experimental (600 mg CaCO3 L-1) devido ao consumo excessivo e ao incremento insuficiente de alcalinidade (<180 mg CaCO3 L-1) a partir do calcário dolomítico. Na segunda etapa, o reator anóxico com composição de leito na relação de 1:3, em condição inicial de alcalinidade de 600 mg CaCO3 L-1, foi operado em TDH de 14, 10 e 6 horas. O reator apresentou eficiências de desnitrificação de 94,4±2,0 e 94,9±2 e 71,1±7,8% e taxas de desnitrificação de 0,115±0,007, 0,164±0,007 e 0,217±0,025 kg NOx m³ -1 d-1 para os TDH de 14, 10 e 6 horas, respectivamente. No TDH de 6 horas, a sobrecarga aplicada e a limitada transferência de massa, devido ao acúmulo de gases no leito, podem ter contribuído para diminuição do desempenho do reator. A terceira etapa abordou estratégias de alimentação com mistura de efluentes amonificado e nitrificado em diferentes proporções de 1:3 (E1), 1:1 (E2) e 3:1 (E3) em reator anóxico-aeróbio de leito fixo de enxofre elementar: calcário dolomítico de 1:3 em condição inicial de alcalinidade de 1000mg CaCO3L-1. O reator apresentou eficiências de remoção de nitrogênio amoniacal e total de 67,3±6,4 e 64,2±6,3% para a condição E1, 63,4±6,4 e 53,1±7,1% para E2 e 14,2±4 e 33,8±1,7% para E3. A geração de sulfeto de hidrogênio a partir, principalmente, do efeito de desproporção do enxofre no compartimento anóxico, pode ter contribuído para a inibição parcial das bactérias nitrificantes. A dificuldade em manter o processo de nitrificação foi caraterizada como fator limitante na remoção de nitrogênio. As baixas eficiências de remoção de nitrogênio total indicaram que a nitrificação seguida da desnitrificação autotrófica, a partir do enxofre elementar em único reator, não foi adequada para remover compostos nitrogenados de efluente anaeróbio de frigorífico avícola
3

NITRIFICAÇÃO E REMOÇÃO DE MATÉRIA ORGÂNICA CARBONÁCEA E SÓLIDOS DE EFLUENTE DOMÉSTICO EM WETLAND CONSTRUÍDO DE FLUXO VERTICAL / NITRIFICATION AND REMOVAL OF ORGANICS AND SOLIDS IN VERTICAL FLOW CONSTRUCTED WETLAND TREATING DOMESTIC WASTEWATER

Decezaro, Samara Terezinha 07 April 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The vertical flow constructed wetlands (VFCW) are attractive systems in the context of on site wastewater treatment, enabling removal of organics and solids and nitrification. However, the satisfactory performance of these reactors depends, in addition to factors such as organic rates and applied hydraulic rates, of hydrodynamic characteristics. Therefore, performance studies and influence hydrodynamic characteristics of VFCW in wastewater treatment are important. The aim of this study was to evaluate the performance of a domestic wastewater treatment system in full scale with a septic tank followed by a VFCW planted with Heliconia psittacorum in nitrification and removal of organics and solids. The septic tank (V = 3.39 m3) was used in primary treatment, and the VFCW (24.5 m2 of surface area) was used in secondary treatment of domestic wastewater. Two operational phases had been evaluated: Phase I Hydraulic load (HL) applied in VFCW was 52.38 mm/d, fragmenting in 4 pulses per day (375 L each pulse); Phase II HL was 54.54 mm/d, with 8 pulses per day (187.5 L each pulse). Besides the variation of influent flow also occurred variation in inflow concentrations, which was higher in phase I. Hydrodynamic tests were performed during the plant development and in different operating conditions using as tracer rhodamine WT. In addition, physical-chemical and biological analyses of wastewater treatment were carried out by means of grab samples. The result of 5 months of operation showed: (i) The operating conditions made possible the micro-organisms adaptation of system (septic tank + VFCW) in domestic wastewater treatment; (ii) With respect to hydrodynamic characteristics of VFCW, it was identified trend of the flow to complete mixing. The average hydraulic retention time (ṫ) was 20 min before planting macrophytes (at the beginning of operation), 17 min after 93 days of plantation and 22 min after 120 days of plantation. When comparing different volumes of pulses, it was found that the application of lower volume pulses (fragmenting daily HL in 8 pulses) provided greater ṫ (26 min); (iii) With respect to performance of the system, the septic tank showed average removal efficiencies of 29%, 46% and 31% for COD, BOD and SS, respectively in phase I and 44%, 45% and 65% for COD , BOD and SS, respectively, during phase II; The VFCW, during phase I, subject to loading of 30.58 g COD/m2.d, 14.54 g BOD/m2.d, 13.11 g SS/m2.d and 3.93 g NH4+-N/m2.d showed an average removal efficiency of 40%, 40%, 32% and 44% for COD, BOD, SS and NH4+-N respectively. In the phase II, the fragmenting of HL in 8 pulses improved the VFCW performance, subjected to loads of 16.87 g COD/m2.d, 8.18 g BOD/m2.d, 4.21 g SS/m2.d and 2.75 g NH4+-N/m2.d, the VFCW had average removal efficiencies of 55%, 61%, 38% and 51% for COD, BOD, SS and NH4+-N, respectively, and, at the end of phase II averaged 58% NH4+-N influent was converted to NO3--N in VFCW. / Os wetlands construídos de fluxo vertical (WCFV) são atrativos no âmbito do tratamento descentralizado de esgotos, possibilitando remoção de matéria orgânica carbonácea e sólidos e a nitrificação. Contudo, o desempenho satisfatório desses reatores depende, além de fatores como cargas orgânicas e taxas hidráulicas aplicadas, das características hidrodinâmicas. Por essa razão, estudos de desempenho e da influência das características hidrodinâmicas de WCFV no tratamento de efluentes são importantes. O objetivo deste estudo foi avaliar o desempenho de um sistema de tratamento de esgoto doméstico em escala real composto por tanque séptico seguido de WCFV, plantado com a macrófita Heliconia psittacorum, na nitrificação e remoção de matéria orgânica carbonácea e sólidos. O tanque séptico (V = 3,39 m3) foi empregado no tratamento primário, e o WCFV (24,5 m2 de área superficial) foi utilizado no tratamento secundário dos esgotos. Foram avaliadas duas fases operacionais: Fase I com taxa de aplicação hidráulica (TAH) no WCFV de 52,38 mm/d, distribuída em 4 pulsos por dia (média de 375 L cada pulso); Fase II com TAH de 54,54 mm/d, sendo 8 pulsos por dia (média de 187,5 L cada pulso). Além da variação da vazão afluente, ocorreu também variação das concentrações afluentes, as quais foram mais elevadas na fase I. Foram realizados testes hidrodinâmicos no decorrer do desenvolvimento das macrófitas e em diferentes condições operacionais, utilizando como traçador a rodamina WT. Além disso, foram realizadas análises físico-químicas e bacteriológicas do efluente, por meio de amostragens pontuais. Com base nos resultados dos 5 primeiros meses de operação, conclui-se que: (i) As condições operacionais possibilitaram a adaptação dos micro-organismos do sistema (tanque séptico + WCFV) ao tratamento de esgoto doméstico; (ii) Quanto às características hidrodinâmicas do WCFV, foi identificado tendência do escoamento ao regime de mistura completa. O tempo médio de detenção hidráulica (ṫ) foi de 20 min antes do transplantio das macrófitas (no início de operação), de 17 min decorridos 93 dias do transplantio e, de 22 min, decorridos 121 dias do transplantio. Ao comparar volumes de pulsos diferentes, foi constatado que a aplicação de pulsos de menor volume (fracionamento da TAH diária em 8 pulsos) proporcionam maior ṫ (26 min); (iii) Quanto ao desempenho do sistema, o tanque séptico apresentou eficiências de remoção médias de 29%, 46% e 31% para DQO, DBO e SS, respectivamente na fase I e de 44%, 45% e 65% para DQO, DBO e SS, respectivamente, durante a fase II. O WCFV, durante a fase I, submetido a carregamentos de 30,58 g DQO/m2.d, 14,54 g DBO/m2.d, 13,11 g SS/m2.d e 3,93 g N-NH4+/m2.d, apresentou eficiências de remoção médias de 40%, 40%, 32% e 44%, para DQO, DBO, SS e N-NH4+, respectivamente. Já na fase II, o fracionamento da TAH diária de projeto em 8 pulsos possibilitou melhoria no desempenho do WCFV, sendo que, submetido a cargas de 16,87 g DQO/m2.d, 8,18 g DBO/m2.d, 4,21 g SS/m2.d e 2,75 g N-NH4+/m2.d, o WCFV apresentou eficiências médias de remoção de 55%, 61%, 38% e 51% para DQO, DBO, SS e N-NH4+, respectivamente, sendo que, no final da fase II em média 58% do N-NH4+ afluente foi convertido em N-NO3- no WCFV.
4

Comportamento de reator anaeróbio-aeróbio no tratamento de efluente bovino / Behavior of an anaerobic-aerobic reactor in cattle slaughterhouse wastewater treatment

Kreutz, Cristiane 13 February 2012 (has links)
Made available in DSpace on 2017-07-10T19:25:20Z (GMT). No. of bitstreams: 1 Cristiane.pdf: 2244710 bytes, checksum: 7f1fb544f09e13f94b271e1202243132 (MD5) Previous issue date: 2012-02-13 / In this study, it was evaluated the operational conditions, the organic matter, nitrogen and phosphorus removal efficiency and the hydrodynamic behavior of a continuously up-flow combined anaerobic-aerobic fixed bed reactor (RAALF), operated in bench-scale, filled with expanded clay and polyurethane foam cubic arrays as means of biomass immobilization support, in the treatment of raw effluent from a cattle slaughterhouse. Three different operational conditions were tested: Step I, characterized by the operation of RAALF in anaerobic condition; Step II, in combined condition (anaerobic-aerobic), and Step III, in combined condition with recirculation. In each operational step three different hydraulic retention times (14, 11 and 8 h) were tested. The hydrodynamics assays were determined using stimulus-response type pulse, with Eosina Y as a tracer to obtain the curves of residence time distribution (RTD). The results from the RAALF in the Step I, under anaerobic condition, indicated that operational conditions ensured the process of anaerobic digestion, with keeping of the pH and the RAALF s buffering, promoting a biochemical balance between acidogenic/acetogenic and methanogenic archaea. In this operational step, the HRT of 11 h showed better result, with removal efficiency of raw COD, filtered COD, TS, TSS and N-amon of 59, 60, 56, 76 and 16%, respectively. In Step II, the HRT of 14 h showed better results in terms of organic matter and solids removal efficiency, with 58, 66, 66 and 84% for raw COD, filtered COD, TS and TSS, respectively. The overall efficiency of nitrogen removal achieved in this study was 0, 17 and 7% at Step I; 37, 22 and 22% in Step II for the HRT 14, 11 and 8 h, respectively, and 50 and 29% for the HDT of 11 and 8 h in Step III. Therefore, there was an evolution in the overall nitrogen removal efficiency in Steps II and III when compared to Step I, due to the partial nitrification and denitrification. Denitrification has been compromised by factors such as liquid temperature, pH, and DQO/N-NO3- ratio. The efficiency of phosphorus removal was 0, 0 and 15% in Step I and 46, 0 and 0% in Step II for HRT 14, 11 and 8 h, respectively, and 10 and 0 % removal HRT to 11 and 8 h, respectively, in Step III. The ANOVA and Tukey tests indicated that the operational stages I, II and III were statistically different for all physical-chemical parameters evaluated, except for phosphorus, for which it can be stated that the efficiency of organic matter and nitrogen removal was affected by the operating condition. The hydrodynamic study conducted at RAALF indicated behavior tending to a complete mixing and deviations from ideality were found, such as dead zones, recirculation and long tail effect. The dispersion degrees were probably influenced by insertion of the aerobic phase, which improved the liquid mixture inside the reactor. The RAALF presented similar kinetic behavior in the operational steps I, II and III, represented by the first order model, with increase of k and vr parameters along the height of the anaerobic phase and decrease of the kinetic constant and degradation rate in the aerobic phase / Neste trabalho foram avaliadas as condições operacionais, a eficiência de remoção de matéria orgânica, nitrogênio e fósforo e o comportamento hidrodinâmico de um reator anaeróbio aeróbio de leito fixo (RAALF) e fluxo ascendente, vertical, operado de modo contínuo, em escala de bancada, preenchido com argila expandida e matrizes cúbicas de espuma de poliuretano como meio suporte para imobilização da biomassa, no tratamento de efluente bruto proveniente de um matadouro bovino. Foram testadas três condições operacionais distintas, sendo a Etapa I caracterizada pela operação do RAALF em condição anaeróbia, a Etapa II em condição combinada (anaeróbia-aeróbia) e a Etapa III em condição combinada com recirculação. Em cada etapa operacional foram testados três tempos de detenção hidráulicos diferentes (14, 11 e 8 h). O comportamento hidrodinâmico foi avaliado utilizando ensaios de estímulo-resposta, tipo pulso, com o uso de Eosina Y como traçador para obtenção das curvas de distribuição do tempo de residência (DTR). Os resultados da avaliação do RAALF na Etapa I, sob condição anaeróbia, indicaram que as condições operacionais garantiram o processo de digestão anaeróbia, com a manutenção do pH e tamponamento do sistema, promovendo um equilíbrio bioquímico entre microrganismos acidogênicos/acetogênicos e arqueas metanogênicas. Nesta etapa operacional, o TDH de 11 h apresentou melhores rendimentos, com eficiência de remoção de DQO bruta, DQO filtrada, ST, SST e N-amon de 59, 60, 56, 76 e 16%, respectivamente. Na Etapa II, o TDH de 14 horas apresentou melhores resultados em termos de eficiência de remoção de matéria orgânica e sólidos, com valores de 58, 66, 66 e 84% para DQO bruta, DQO filtrada, ST e SST, respectivamente. A eficiência global de remoção de nitrogênio alcançada neste estudo foi de 0, 17 e 7% na Etapa I, 37, 22 e 22% na Etapa II, para o TDH de 14, 11 e 8 h, respectivamente, e de 50 e 29% para o TDH de 11 e 8 h na Etapa III; portanto, verifica-se evolução da eficiência global na remoção de nitrogênio das Etapas II e III se comparada à Etapa I, decorrente do processo de nitrificação e desnitrificação parcial. A desnitrificação foi comprometida por fatores como temperatura do líquido, pH e relação DQO/N-NO3-. As eficiências de remoção de fósforo total foram de 0, 0 e 15% na Etapa I e de 46, 0 e 0% na Etapa II para os TDHs de 14, 11 e 8 h, respectivamente, e de 10 e 0% de remoção para o THD de 11 e 8 h, respectivamente, na Etapa III. O teste ANOVA e o teste Tukey indicaram que as etapas operacionais I, II e III foram estatisticamente diferentes entre si, para todos os parâmetros físico-químicos avaliados, com exceção do fósforo, podendo-se afirmar que a eficiência de remoção de matéria orgânica e nitrogenada foi afetada pela condição operacional. O estudo hidrodinâmico realizado no RAALF indicou comportamento tendendo ao de mistura completa e foram constatados desvios de idealidade, como zonas mortas, recirculações e efeito de cauda longa. Os graus de dispersão foram possivelmente influenciados pela inserção da fase aeróbia, que promoveu uma melhor mistura do líquido no interior do reator. O RAALF apresentou comportamento cinético similar nas etapas operacionais I, II e III, representado pelo modelo de primeira ordem, com aumento dos parâmetros k e vr ao longo da altura da fase anaeróbia, e diminuição da constante cinética e da velocidade de degradação na fase aeróbia
5

Comportamento de reator anaeróbio-aeróbio no tratamento de efluente bovino / Behavior of an anaerobic-aerobic reactor in cattle slaughterhouse wastewater treatment

Kreutz, Cristiane 13 February 2012 (has links)
Made available in DSpace on 2017-05-12T14:48:43Z (GMT). No. of bitstreams: 1 Cristiane.pdf: 2244710 bytes, checksum: 7f1fb544f09e13f94b271e1202243132 (MD5) Previous issue date: 2012-02-13 / In this study, it was evaluated the operational conditions, the organic matter, nitrogen and phosphorus removal efficiency and the hydrodynamic behavior of a continuously up-flow combined anaerobic-aerobic fixed bed reactor (RAALF), operated in bench-scale, filled with expanded clay and polyurethane foam cubic arrays as means of biomass immobilization support, in the treatment of raw effluent from a cattle slaughterhouse. Three different operational conditions were tested: Step I, characterized by the operation of RAALF in anaerobic condition; Step II, in combined condition (anaerobic-aerobic), and Step III, in combined condition with recirculation. In each operational step three different hydraulic retention times (14, 11 and 8 h) were tested. The hydrodynamics assays were determined using stimulus-response type pulse, with Eosina Y as a tracer to obtain the curves of residence time distribution (RTD). The results from the RAALF in the Step I, under anaerobic condition, indicated that operational conditions ensured the process of anaerobic digestion, with keeping of the pH and the RAALF s buffering, promoting a biochemical balance between acidogenic/acetogenic and methanogenic archaea. In this operational step, the HRT of 11 h showed better result, with removal efficiency of raw COD, filtered COD, TS, TSS and N-amon of 59, 60, 56, 76 and 16%, respectively. In Step II, the HRT of 14 h showed better results in terms of organic matter and solids removal efficiency, with 58, 66, 66 and 84% for raw COD, filtered COD, TS and TSS, respectively. The overall efficiency of nitrogen removal achieved in this study was 0, 17 and 7% at Step I; 37, 22 and 22% in Step II for the HRT 14, 11 and 8 h, respectively, and 50 and 29% for the HDT of 11 and 8 h in Step III. Therefore, there was an evolution in the overall nitrogen removal efficiency in Steps II and III when compared to Step I, due to the partial nitrification and denitrification. Denitrification has been compromised by factors such as liquid temperature, pH, and DQO/N-NO3- ratio. The efficiency of phosphorus removal was 0, 0 and 15% in Step I and 46, 0 and 0% in Step II for HRT 14, 11 and 8 h, respectively, and 10 and 0 % removal HRT to 11 and 8 h, respectively, in Step III. The ANOVA and Tukey tests indicated that the operational stages I, II and III were statistically different for all physical-chemical parameters evaluated, except for phosphorus, for which it can be stated that the efficiency of organic matter and nitrogen removal was affected by the operating condition. The hydrodynamic study conducted at RAALF indicated behavior tending to a complete mixing and deviations from ideality were found, such as dead zones, recirculation and long tail effect. The dispersion degrees were probably influenced by insertion of the aerobic phase, which improved the liquid mixture inside the reactor. The RAALF presented similar kinetic behavior in the operational steps I, II and III, represented by the first order model, with increase of k and vr parameters along the height of the anaerobic phase and decrease of the kinetic constant and degradation rate in the aerobic phase / Neste trabalho foram avaliadas as condições operacionais, a eficiência de remoção de matéria orgânica, nitrogênio e fósforo e o comportamento hidrodinâmico de um reator anaeróbio aeróbio de leito fixo (RAALF) e fluxo ascendente, vertical, operado de modo contínuo, em escala de bancada, preenchido com argila expandida e matrizes cúbicas de espuma de poliuretano como meio suporte para imobilização da biomassa, no tratamento de efluente bruto proveniente de um matadouro bovino. Foram testadas três condições operacionais distintas, sendo a Etapa I caracterizada pela operação do RAALF em condição anaeróbia, a Etapa II em condição combinada (anaeróbia-aeróbia) e a Etapa III em condição combinada com recirculação. Em cada etapa operacional foram testados três tempos de detenção hidráulicos diferentes (14, 11 e 8 h). O comportamento hidrodinâmico foi avaliado utilizando ensaios de estímulo-resposta, tipo pulso, com o uso de Eosina Y como traçador para obtenção das curvas de distribuição do tempo de residência (DTR). Os resultados da avaliação do RAALF na Etapa I, sob condição anaeróbia, indicaram que as condições operacionais garantiram o processo de digestão anaeróbia, com a manutenção do pH e tamponamento do sistema, promovendo um equilíbrio bioquímico entre microrganismos acidogênicos/acetogênicos e arqueas metanogênicas. Nesta etapa operacional, o TDH de 11 h apresentou melhores rendimentos, com eficiência de remoção de DQO bruta, DQO filtrada, ST, SST e N-amon de 59, 60, 56, 76 e 16%, respectivamente. Na Etapa II, o TDH de 14 horas apresentou melhores resultados em termos de eficiência de remoção de matéria orgânica e sólidos, com valores de 58, 66, 66 e 84% para DQO bruta, DQO filtrada, ST e SST, respectivamente. A eficiência global de remoção de nitrogênio alcançada neste estudo foi de 0, 17 e 7% na Etapa I, 37, 22 e 22% na Etapa II, para o TDH de 14, 11 e 8 h, respectivamente, e de 50 e 29% para o TDH de 11 e 8 h na Etapa III; portanto, verifica-se evolução da eficiência global na remoção de nitrogênio das Etapas II e III se comparada à Etapa I, decorrente do processo de nitrificação e desnitrificação parcial. A desnitrificação foi comprometida por fatores como temperatura do líquido, pH e relação DQO/N-NO3-. As eficiências de remoção de fósforo total foram de 0, 0 e 15% na Etapa I e de 46, 0 e 0% na Etapa II para os TDHs de 14, 11 e 8 h, respectivamente, e de 10 e 0% de remoção para o THD de 11 e 8 h, respectivamente, na Etapa III. O teste ANOVA e o teste Tukey indicaram que as etapas operacionais I, II e III foram estatisticamente diferentes entre si, para todos os parâmetros físico-químicos avaliados, com exceção do fósforo, podendo-se afirmar que a eficiência de remoção de matéria orgânica e nitrogenada foi afetada pela condição operacional. O estudo hidrodinâmico realizado no RAALF indicou comportamento tendendo ao de mistura completa e foram constatados desvios de idealidade, como zonas mortas, recirculações e efeito de cauda longa. Os graus de dispersão foram possivelmente influenciados pela inserção da fase aeróbia, que promoveu uma melhor mistura do líquido no interior do reator. O RAALF apresentou comportamento cinético similar nas etapas operacionais I, II e III, representado pelo modelo de primeira ordem, com aumento dos parâmetros k e vr ao longo da altura da fase anaeróbia, e diminuição da constante cinética e da velocidade de degradação na fase aeróbia

Page generated in 0.0941 seconds