  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

The MouthPad - a Tongue Interface for Hands-Free Computer Control

Draghici, Ovidiu January 2014 (has links)
Tongue-computer interfaces allow people with upper limb disability to control a computer with their tongue. A number of assistive devices, that make use of this technology, have been developed in the last two decades: some employ contact impedance, membrane switches, or miniature joysticks, while others use magnetic or piezoelectric sensors. This thesis proposes a new tongue-computer interface, which was designed to enable users to manipulate a computer pointer by moving the tip of their tongue over an intraoral electrode array. The system maps the contact between the tongue and the electrodes, detects the movements of the tongue, and translates it into pointer movements. Compared to similar devices, the MouthPad does not require any head gear or sensors, and does not employ heavy signal processing. The hardware is simplified by using a small number of electrodes and only one output channel, multiplexed over the electrode array. A low power footprint allows the potential miniaturization of the system, so that it could fit on palatal retainer, and allow for permanent unobtrusive usage. The performance of the device was evaluated by measuring the throughput and the accuracy as defined in ISO 9241-9 standard. Two extra measures proposed in the literature, target re-entry and movement offset, were used for the evaluation of the accuracy. The measured throughput values were situated between 78% and 88% of the throughput rates of regular computer joysticks.
62

Bayesian Approach to Dynamically Controlling Data Collection in P300 Spellers

Throckmorton, Chandra S., Colwell, Kenneth A., Ryan, David B., Sellers, Eric W., Collins, Leslie M. 22 May 2013 (has links)
P300 spellers provide a noninvasive method of communication for people who may not be able to use other communication aids due to severe neuromuscular disabilities. However, P300 spellers rely on event-related potentials (ERPs) which often have low signal-to-noise ratios (SNRs). In order to improve detection of the ERPs, P300 spellers typically collect multiple measurements of the electroencephalography (EEG) response for each character. The amount of collected data can affect both the accuracy and the communication rate of the speller system. The goal of the present study was to develop an algorithm that would automatically determine the necessary amount of data to collect during operation. Dynamic data collection was controlled by a threshold on the probabilities that each possible character was the target character, and these probabilities were continually updated with each additional measurement. This Bayesian technique differs from other dynamic data collection techniques by relying on a participant-independent, probability-based metric as the stopping criterion. The accuracy and communication rate for dynamic and static data collection in P300 spellers were compared for 26 users. Dynamic data collection resulted in a significant increase in accuracy and communication rate.
63

Whether Generic Model Works for Rapid ERP-based BCI Calibration

Jin, Jing, Sellers, Eric W., Zhang, Yu, Daly, Ian, Wang, Xingyu, Cichocki, Andrzej 01 January 2013 (has links)
Event-related potential (ERP)-based brain-computer interfacing (BCI) is an effective method of basic communication. However, collecting calibration data, and classifier training, detracts from the amount of time allocated for online communication. Decreasing calibration time can reduce preparation time thereby allowing for additional online use, potentially lower fatigue, and improved performance. Previous studies, using generic online training models which avoid offline calibration, afford more time for online spelling. Such studies have not examined the direct effects of the model on individual performance, and the training sequence exceeded the time reported here.The first goal of this work is to survey whether one generic model works for all subjects and the second goal is to show the performance of a generic model using an online training strategy when participants could use the generic model. The generic model was derived from 10 participant's data. An additional 11 participants were recruited for the current study. Seven of the participants were able to use the generic model during online training. Moreover, the generic model performed as well as models obtained from participant specific offline data with a mean training time of less than 2. min. However, four of the participants could not use this generic model, which shows that one generic mode is not generic for all subjects. More research on ERPs of subjects with different characteristics should be done, which would be helpful to build generic models for subject groups. This result shows a potential valuable direction for improving the BCI system.
64

Bayesian Approach to Dynamically Controlling Data Collection in P300 Spellers

Throckmorton, Chandra S., Colwell, Kenneth A., Ryan, David B., Sellers, Eric W., Collins, Leslie M. 22 May 2013 (has links)
P300 spellers provide a noninvasive method of communication for people who may not be able to use other communication aids due to severe neuromuscular disabilities. However, P300 spellers rely on event-related potentials (ERPs) which often have low signal-to-noise ratios (SNRs). In order to improve detection of the ERPs, P300 spellers typically collect multiple measurements of the electroencephalography (EEG) response for each character. The amount of collected data can affect both the accuracy and the communication rate of the speller system. The goal of the present study was to develop an algorithm that would automatically determine the necessary amount of data to collect during operation. Dynamic data collection was controlled by a threshold on the probabilities that each possible character was the target character, and these probabilities were continually updated with each additional measurement. This Bayesian technique differs from other dynamic data collection techniques by relying on a participant-independent, probability-based metric as the stopping criterion. The accuracy and communication rate for dynamic and static data collection in P300 spellers were compared for 26 users. Dynamic data collection resulted in a significant increase in accuracy and communication rate.
65

Whether Generic Model Works for Rapid ERP-based BCI Calibration

Jin, Jing, Sellers, Eric W., Zhang, Yu, Daly, Ian, Wang, Xingyu, Cichocki, Andrzej 01 January 2013 (has links)
Event-related potential (ERP)-based brain-computer interfacing (BCI) is an effective method of basic communication. However, collecting calibration data, and classifier training, detracts from the amount of time allocated for online communication. Decreasing calibration time can reduce preparation time thereby allowing for additional online use, potentially lower fatigue, and improved performance. Previous studies, using generic online training models which avoid offline calibration, afford more time for online spelling. Such studies have not examined the direct effects of the model on individual performance, and the training sequence exceeded the time reported here.The first goal of this work is to survey whether one generic model works for all subjects and the second goal is to show the performance of a generic model using an online training strategy when participants could use the generic model. The generic model was derived from 10 participant's data. An additional 11 participants were recruited for the current study. Seven of the participants were able to use the generic model during online training. Moreover, the generic model performed as well as models obtained from participant specific offline data with a mean training time of less than 2. min. However, four of the participants could not use this generic model, which shows that one generic mode is not generic for all subjects. More research on ERPs of subjects with different characteristics should be done, which would be helpful to build generic models for subject groups. This result shows a potential valuable direction for improving the BCI system.
66

A P300 Brain-Computer Interface Based on a Modification of the Mismatch Negativity Paradigm

Jin, Jing, Sellers, Eric W., Zhou, Sijie, Zhang, Yu, Wang, Xingyu, Cichocki, Andrzej 01 January 2015 (has links)
The P300-based brain-computer interface (BCI) is an extension of the oddball paradigm, and can facilitate communication for people with severe neuromuscular disorders. It has been shown that, in addition to the P300, other event-related potential (ERP) components have been shown to contribute to successful operation of the P300 BCI. Incorporating these components into the classification algorithm can improve the classification accuracy and information transfer rate (ITR). In this paper, a single character presentation paradigm was compared to a presentation paradigm that is based on the visual mismatch negativity. The mismatch negativity paradigm showed significantly higher classification accuracy and ITRs than a single character presentation paradigm. In addition, the mismatch paradigm elicited larger N200 and N400 components than the single character paradigm. The components elicited by the presentation method were consistent with what would be expected from a mismatch paradigm and a typical P300 was also observed. The results show that increasing the signal-to-noise ratio by increasing the amplitude of ERP components can significantly improve BCI speed and accuracy. The mismatch presentation paradigm may be considered a viable option to the traditional P300 BCI paradigm.
67

Channel Selection Methods for the P300 Speller

Colwell, K. A., Ryan, D. B., Throckmorton, C. S., Sellers, E. W., Collins, L. M. 30 July 2014 (has links)
The P300 Speller brain-computer interface (BCI) allows a user to communicate without muscle activity by reading electrical signals on the scalp via electroencephalogram. Modern BCI systems use multiple electrodes ("channels") to collect data, which has been shown to improve speller accuracy; however, system cost and setup time can increase substantially with the number of channels in use, so it is in the user's interest to use a channel set of modest size. This constraint increases the importance of using an effective channel set, but current systems typically utilize the same channel montage for each user. We examine the effect of active channel selection for individuals on speller performance, using generalized standard feature-selection methods, and present a new channel selection method, termed jumpwise regression, that extends the Stepwise Linear Discriminant Analysis classifier. Simulating the selections of each method on real P300 Speller data, we obtain results demonstrating that active channel selection can improve speller accuracy for most users relative to a standard channel set, with particular benefit for users who experience low performance using the standard set. Of the methods tested, jumpwise regression offers accuracy gains similar to the best-performing feature-selection methods, and is robust enough for online use.
68

A Comprehensive Review of EEG-Based Brain-Computer Interface Paradigms

Abiri, Reza, Borhani, Soheil, Sellers, Eric W., Jiang, Yang, Zhao, Xiaopeng 01 February 2019 (has links)
Advances in brain science and computer technology in the past decade have led to exciting developments in brain-computer interface (BCI), thereby making BCI a top research area in applied science. The renaissance of BCI opens new methods of neurorehabilitation for physically disabled people (e.g. paralyzed patients and amputees) and patients with brain injuries (e.g. stroke patients). Recent technological advances such as wireless recording, machine learning analysis, and real-time temporal resolution have increased interest in electroencephalographic (EEG) based BCI approaches. Many BCI studies have focused on decoding EEG signals associated with whole-body kinematics/kinetics, motor imagery, and various senses. Thus, there is a need to understand the various experimental paradigms used in EEG-based BCI systems. Moreover, given that there are many available options, it is essential to choose the most appropriate BCI application to properly manipulate a neuroprosthetic or neurorehabilitation device. The current review evaluates EEG-based BCI paradigms regarding their advantages and disadvantages from a variety of perspectives. For each paradigm, various EEG decoding algorithms and classification methods are evaluated. The applications of these paradigms with targeted patients are summarized. Finally, potential problems with EEG-based BCI systems are discussed, and possible solutions are proposed.
69

P300 Brain Computer Interface: Current Challenges and Emerging Trends

Fazel-Rezai, Reza, Allison, Brendan Z., Guger, Christoph, Sellers, Eric W., Kleih, Sonja C., Kübler, Andrea 21 June 2012 (has links)
A brain-computer interface (BCI) enables communication without movement based on brain signals measured with electroencephalography (EEG). BCIs usually rely on one of three types of signals: the P300 and other components of the event-related potential (ERP), steady state visual evoked potential (SSVEP), or event related desynchronization (ERD). Although P300 BCIs were introduced over twenty years ago, the past few years have seen a strong increase in P300 BCI research. This closed-loop BCI approach relies on the P300 and other components of the event-related potential (ERP), based on an oddball paradigm presented to the subject. In this paper, we overview the current status of P300 BCI technology, and then discuss new directions: paradigms for eliciting P300s; signal processing methods; applications; and hybrid BCIs. We conclude that P300 BCIs are quite promising, as several emerging directions have not yet been fully explored and could lead to improvements in bit rate, reliability, usability, and flexibility.
70

Observing P300 Amplitudes in Multiple Sensory Channels using Cognitive Probing

Wintermute, Cody Lee 28 August 2020 (has links)
No description available.